Murata AAF BCG Sensor Node User Manual 82217800C SCA11H user guide signed

Murata Manufacturing Co., Ltd. BCG Sensor Node 82217800C SCA11H user guide signed

Contents

Users Manual

Download: Murata AAF BCG Sensor Node User Manual 82217800C SCA11H user guide signed
Mirror Download [FCC.gov]Murata AAF BCG Sensor Node User Manual 82217800C SCA11H user guide signed
Document ID2693895
Application IDW+1r/B9fkVFJFMb6Leo0ig==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize45.16kB (564475 bits)
Date Submitted2015-07-27 00:00:00
Date Available2015-07-27 00:00:00
Creation Date2015-06-16 11:02:11
Producing SoftwareAcrobat Distiller 10.1.7 (Windows)
Document Lastmod2015-06-16 11:02:11
Document Title82217800C_SCA11H_user guide_signed.pdf
Document CreatorAcrobat PDFMaker 10.1 for Word
Document Author: Jasmin Gutiérrez

15-June-15
BCG Bed Sensor
Node SCA11H
Installation Guide
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
1/17
Rev.C
15-June-15
TABLE OF CONTENTS
SCA11H PRODUCT CONTENT .............................................................................................. 3
SCA11H OPERATION MODES .............................................................................................. 4
2.1
2.2
CONFIGURATION ........................................................................................................................ 4
LOCAL COMMUNICATION MODE .................................................................................................... 4
SCA11H USER INTERFACE ................................................................................................... 5
SCA11H INSTALLATION....................................................................................................... 6
4.1
4.2
4.3
4.4
4.5
POSITIONING SCA11H INTO THE BED ............................................................................................ 6
SETTING SCA11H INTO CONFIGURATION MODE (APPENDIX 1) ........................................................... 8
CONFIGURATION (APPENDIX 1 AND 2) ........................................................................................... 8
CALIBRATION .......................................................................................................................... 11
COMPLETING CONFIGURATION.................................................................................................... 13
TESTING THE OUTPUT OF SCA11H .................................................................................... 14
CARE INSTRUCTIONS AND SAFETY UTILIZATION................................................................ 14
DECLARATIONS ................................................................................................................ 14
APPENDIXES .................................................................................................................... 15
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
2/17
Rev.C
15-June-15
1 SCA11H product content
Figure 1. SCA11H-Xxx
BCG sensor node
Power adapter
o 9V/500mA switching power supply with 2.1/5.5 mm plug.
o Four different power plugs are supported according to the table below.
Product type
SCA11H-A01
Note www.iec.ch/worldplugs
AC-adapter type A
US, Canada, Mexico and Japan…
SCA11H-P01
AC-adapter type A
China
SCA11H-C01
AC-adapter type C
Europe, South America and Asia…
SCA11H-G01
AC-adapter type G
UK, Ireland, Malta, Malaysia,
Singapore…
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
3/17
Rev.C
15-June-15
2 SCA11H operation modes
2.1
Configuration
In configuration mode SCA11H creates its own network.
Following configurations and settings can be made using configuration WEB page.
1.
2.
3.
4.
Communication – local vs cloud
BCG measurement related settings
Network settings
BCG-calibration
Figure 2. Configuration WEB page
2.2
Local communication mode
In local communication mode SCA11H connects to pre-defined WiFi network.
• SCA11H sensor node works as TCP/IP-server and writes output data in ASCIIformat in the defined IP-address port 8080
• Simple Service Discovery Protocol SSDP is used for device discovery
• Sensor node can be calibrated and maintained using the HTTP API according to
SCA11H Hostless WLAN HTTP API Specification 82218200.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
4/17
Rev.C
15-June-15
3 SCA11H user interface
After initialization with the attachment plate LEDs on the top indicate the following
functions:
1. Power (green)
x Blinking:
x Static on:
2. Network (orange)
x Flash:
3. Status (green)
x Flash:
connecting to network
connected to network
network traffic (transmission or reception)
BCG data transmission
After initialization without the attachment plate (approx. 10s) LEDs indicate the following
functions:
1. Power (green)
x Blinking:
2. Network (orange)
x Flash:
3. Status (green)
x Off
configuration mode
network traffic (transmission or reception)
Figure 3. SCA11H User Interface
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
5/17
Rev.C
15-June-15
4 SCA11H installation
4.1
Positioning SCA11H into the bed
Positioning of SCA11H is very important. Please note two main items:
1. Orientation of the SCA11H needs to be the same as printed on top of the node
(head to toes)
2. SCA11H measures the bed vibration caused by blood circulation and therefore it
needs to be positioned in a place most optimal to measure this vibration.
Figure 4 depicts possible positioning options for SCA11H.
1. Under the mattress pad. Do not place under a person but rather on the side or
edge of the mattress. The recommended distance to the person to be measured is
min 20 cm.
2. On the bed frame or
3. On the side of the bed
Figure 4. Position options for SCA11H
In addition the socket-outlet shall be installed near the equipment and shall be easily
accessible.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
6/17
Rev.C
15-June-15
More examples for good positioning of SCA11H are shown in Figure 5.
Figure 5. Examples of good SCA11H attachment positions
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
7/17
Rev.C
15-June-15
4.2
Setting SCA11H into configuration mode (Appendix 1)
1. Ensure power is disconnected
2. Remove SCA11H from the attachment plate (attachment plate is the black plate
attached with magnet to actual SCA11H sensor node, please see the figure below)
3. Plug in the power
4. Wait about 5 s until the green power led starts to blink with 1s interval
5. Attach SCA11H sensor node to the black attachment plate
6. After steps 1-5 SCA11H is ready for positioning and configuration.
attachment plate
Figure 6. SCA11H node without attachment plate
4.3
Configuration (Appendix 1 and 2)
1. Connect the used configuration device (for example laptop) to SCA11H's
configuration network: muRata_CFG_XXXXXX using password: 24681012.
Figure 7. Example SCA11H's configuration network.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
8/17
Rev.C
15-June-15
2. Open the browser at page http://192.168.253.1
Figure 8. Start-up page
3. Select Advanced Bed Sensor Settings
Figure 9. Advanced Bed Sensor Settings
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
9/17
Rev.C
15-June-15
4. Select “BCG Mode” for algorithm data output or “Data Logger Mode” for raw
data output.
5. Select “Normal” as measurement direction.
6. Click “Apply” if changes were made.
Remark: Do not modify calibration parameters manually without in-depth understanding!
Select Communication Settings tab
Figure 10. Communication Settings
7. Select “Local Mode” if you are operating in local network or “Cloud Mode” if
data is sent to a cloud server.
8. If cloud mode is selected, please follow the service provider instructions to
configure the parameters.
9. Click “Apply” if changes were made.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
10/17
Rev.C
15-June-15
Select Network Settings tab
Figure 10. Network Settings
10. Select the local network where to connect SCA11H bed sensor node and enter
the network password.
4.4
Calibration
Calibration is recommended to be carried out separately for each person in bed. If the
person in bed changes, calibration should be repeated in order to obtain reliable results
for each person.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
11/17
Rev.C
15-June-15
Select Bed Sensor Settings tab
Figure 11. Calibration
1. Make sure that the SCA11H is positioned as instructed in chapter 4.2, bed is
empty and it is not exposed to disturbances.
2. Start the empty bed calibration by clicking the “Start” button. This takes 1
minute. In case of disturbances the calibration can be started again. When
succeeded, bed has been calibrated to the environment.
3. After empty bed calibration has been successfully performed SCA11H can be
calibrated for the occupied bed. The monitored person should lie still on the bed
and the occupied bed calibration can be started by clicking the “Start” button.
This takes also 1 minute.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
12/17
Rev.C
15-June-15
4.5
Completing configuration
Select System Info tab
Figure 12. System Info
Check the configured settings are correct. If yes, click ”Reboot to complete configuration”.
SCA11H Bed Sensor Node has now been configured.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
13/17
Rev.C
15-June-15
5 Testing the output of SCA11H
When using SCA11H the first time with the specific bed it is recommended to ensure
proper sensor position. Please use e.g. separately provided BCGDemoGUI to verify the
measured raw data contains periodic signal due to pulse. If no periodic signal can be
seen, sensor position should be improved.
6 Care Instructions and Safety Utilization
SCA11H is maintenance free. AC-adapter must be disconnected from the power when
cleaning the bed to avoid electric shock due to water or moisture.
SCA11H does not need to be reconfigured or recalibrated in case of power out.
7 Declarations
- SCA11H operating temperature range is 10 to 55 °C
- Non-authorized modification by user is prohibited.
- SCA11H sensor is not a medical device and has not been validated or approved as
such. It should not be used to diagnose or treat medical conditions.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
14/17
Rev.C
15-June-15
8 Appendixes
Appendix 1
Setting up SCA11H to the configuration mode
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
15/17
Rev.C
15-June-15
Appendix 2
SCA11H Configuration and Calibration using configuration WEB page
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
16/17
Rev.C
15-June-15
Appendix 3
FCC regulations
NOTICE:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1)
this device may not cause harmful interference, and
(2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTICE:
Changes or modifications made to this equipment not expressly approved by Murata
Manufacturing Co., Ltd. may void the FCC authorization to operate this equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Radiofrequency radiation exposure Information:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of
20 cm between the radiator and your body. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
Murata Electronics Oy
www.murata.com
Doc. nr. 82 2178 00
17/17
Rev.C

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Jasmin Gutiérrez
Create Date                     : 2015:06:16 11:02:11+03:00
Modify Date                     : 2015:06:16 11:02:11+03:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2015:06:16 11:01:29+03:00
Creator Tool                    : Acrobat PDFMaker 10.1 for Word
Document ID                     : uuid:98e73980-ddcf-44ae-b477-3102d6f21fe5
Instance ID                     : uuid:c21f7570-675a-42dc-b455-216ccfa5464c
Subject                         : 5
Format                          : application/pdf
Creator                         : Jasmin Gutiérrez
Title                           : 82217800C_SCA11H_user guide_signed.pdf
Producer                        : Acrobat Distiller 10.1.7 (Windows)
Source Modified                 : D:20150616080054
Company                         : VTI Technologies
Page Count                      : 17
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VPYAAF

Navigation menu