NEXCOM EWF3210K Industrial IEEE 802.11a/b/g/n AP module User Manual

NEXCOM international Co.,LTD Industrial IEEE 802.11a/b/g/n AP module

User manual

              802.11a/b/g/n  Industrial  WiFi  module EWF3210K User  Manual-QIG V1.1
Preface This manual is for WLAN service providers or network administrators to set up a network environment using the IWF series Product line. It contains step-by-step procedures and graphic examples to guide MIS staff or individuals with slight network system knowledge to complete the installation. Copyright This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from NEXCOM International Co., Ltd. Disclaimer The information in this document is subject to change without prior notice and does not represent commitment from NEXCOM International Co., Ltd. However, users may update their knowledge of any product in use by constantly checking its manual posted on our website: http://www.nexcom.com. NEXCOM shall not be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of any product, nor for any infringements upon the rights of third parties, which may result from such use. Any implied warranties of merchantability or fitness for any particular purpose is also disclaimed. Acknowledgements IWF 300 is trademarks of NEXCOM International Co., Ltd. All other product names mentioned herein are registered trademarks of their respective owners. Regulatory Compliance Statements This section provides the FCC compliance statement for Class B devices and describes how to keep the system CE compliant. Declaration of Conformity Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may  cause  harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: Any changes or  modifications  not  expressly approved by the party  responsible for compliance could void the user's authority to operate this equipment.  This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  IMPORTANT NOTE: Radiation Exposure Statement: This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled environment.  This  equipment  should  be  installed  and  operated  with  minimum  distance  20cm between the radiator & your body.  This  transmitter  must  not  be  co-located  or  operating  in  conjunction  with  any  other  antenna  or transmitter.  Country Code selection feature to be disabled for products marketed to the US/CANADA  Operation of this device is restricted to indoor use only
This device is intended only for OEM integrators under the following conditions: The antenna must be installed such that 20 cm is maintained between the antenna and users, and   The transmitter module may not be co-located with any other transmitter or antenna,   For all products market in US, OEM has to limit the operation channels in CH1 to CH11 for 2.4G band by supplied firmware programming tool. OEM shall not supply any tool or info to the end-user regarding to Regulatory Domain change.  As long as 3 conditions above are met, further transmitter test will not be required. However, the OEM  integrator  is  still  responsible  for  testing  their  end-product  for  any  additional  compliance requirements required with this module installed  IMPORTANT NOTE In  the  event  that  these  conditions  can  not  be  met  (for  example  certain  laptop  configurations  or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling This transmitter  module is authorized only for use in  device where the  antenna may be  installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID: YHI-EWF3210K”.  Manual Information to the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install  or  remove  this  RF  module  in  the  user’s  manual  of  the  end  product  which  integrates  this module.The end user manual shall include all required regulatory information/warning as show in this manual.  CE The product(s) described in this manual complies with all applicable European Union (CE) directives if it has a CE marking. For computer systems to remain CE compliant, only CE-compliant parts may be used. Maintaining CE compliance also requires proper cable and cabling techniques.
RoHS Compliance NEXCOM RoHS Environmental Policy and Status Update NEXCOM is a global citizen for building the digital infrastructure. We are committed to providing green products and services, which are compliant with European Union RoHS (Restriction on Use of Hazardous Substance in Electronic Equipment) directive 2011/65/EU, to be your trusted green partner and to protect our environment. RoHS restricts the use of Lead (Pb) < 0.1% or 1,000ppm, Mercury (Hg) < 0.1% or 1,000ppm, Cadmium (Cd) < 0.01% or 100ppm, Hexavalent Chromium (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) < 0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or 1,000ppm. In order to meet the RoHS compliant directives, NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products. The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality levels for which NEXCOM are renowned. The model selection criteria will be based on market demand. Vendors and suppliers will ensure that all designed components will be RoHS compliant. How to recognize NEXCOM RoHS Products? For existing products where there are non-RoHS and RoHS versions, the suffix “(LF)” will be added to the compliant product name. All new product models launched after January 2013 will be RoHS compliant. They will use the usual NEXCOM naming convention. Safety Information Before installing and using the device, note the following precautions: ▪▪ Read all instructions carefully. ▪▪ Do not place the unit on an unstable surface, cart, or stand. ▪▪ Follow all warnings and cautions in this manual. ▪▪ When replacing parts, ensure that your service technician uses parts specified by the anufacturer. ▪▪ Avoid using the system near water, in direct sunlight, or near a heating device. Installation Recommendations
Ensure you have a stable, clean working environment. Dust and dirt can get into components and cause a malfunction. Use containers to keep small components separated. Adequate lighting and proper tools can prevent you from accidentally damaging the internal components. Most of the procedures that follow require only a few simple tools, including the following: ▪▪ A Philips screwdriver ▪▪ A flat-tipped screwdriver ▪▪ A grounding strap ▪▪ An anti-static pad Using your fingers can disconnect most of the connections. It is recommended that you do not use needle-nose pliers to disconnect connections as these can damage the soft metal or plastic parts of the connectors. Safety Precautions 1. Read these safety instructions carefully. 2. Keep this User Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a stable surface during installation. Dropping it or letting it fall may cause damage. 7. The openings on the enclosure are for air convection to protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. 9. Place the power cord in a way so that people will not step on it. Do not place anything on top of the power cord. Use a power cord that has been approved for use with the product and that it matches the voltage and current marked on the product’s electrical range label. The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product. 10. All cautions and warnings on the equipment should be noted. 11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by
qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work according to the user’s manual. e. The equipment has been dropped and damaged. f. The equipment has obvious signs of breakage. 15. Do not place heavy objects on the equipment. 16. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS. Technical Support and Assistance 1. For the most updated information of NEXCOM products, visit NEXCOM’s website at www.nexcom.com. 2. For technical issues that require contacting our technical support team or sales representative, please have the following information ready before calling: – Product name and serial number – Detailed information of the peripheral devices – Detailed information of the installed software (operating system, version, application software, etc.) – A complete description of the problem – The exact wordings of the error messages Warnings Read and adhere to all warnings, cautions, and notices in this guide and the documentation supplied with the chassis, power supply, and accessory modules. If the instructions for the chassis and power supply are inconsistent with these instructions or the instructions for accessory modules, contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements. 1. Handling the unit: carry the unit with both hands and handle it with care. 2. Opening the enclosure: disconnect power before working on the unit to prevent electrical shocks. 3. Maintenance: to keep the unit clean, use only approved cleaning products or clean with a dry
cloth. Cautions Electrostatic discharge (ESD) can damage system components. Do the described procedures only at an ESD workstation. If no such station is available, you can provide some ESD protection by wearing an antistatic wrist strap and attaching it to a metal part of the computer chassis. Conventions Used in this Manual Warning: Information about certain situations, which if not observed, can cause personal injury. This will prevent injury to yourself when performing a task.  Caution: Information to avoid damaging components or losing data. Note: Provides additional information to complete a task easily.
Contents
1. Introduction EWF3210K is QCA9344-based industrial-grade AP/CPE/Router/EZ MESH AP designed with IEEE802.11a/b/g/n 2x2 MIMO technology. EWF3210K can deliver data rate up to 1.16Gbps. In addition, the Radio power can be up to 27dBm for wide range coverage and service.
2. Interface        Package Contents ● EWF3210K 802.11a/b/g/n Industrial WiFu Module x1      3. System Information 3.1 Config setting  To access the system to configuration, launch the web browser on your computer, and enter the device IP address in the Address field of the web browser. The factory default IP address: 192.168.1.1.   A login screen will appear. Go to the login page by Click the “Login”    Login ID and password is not required before access the system web user’s interface.   WAN LAN DC   12V
3.2 System status-Overview Click Status button to see information   3.3 System status-Routes Click Status button to see information  3.4 System status-System Log Click Status button to see information  3.5 System status-Kernal Log Click Status button to see information   3.6 System status-Processes Click Status button to see information  3.7 System status-Real-time Load    Click Status button to see information
4. System Configuration   4.1 System   Click System button to see information   4.2 System Administration Click Administration button to see information and change the user name and password here.   4.3 System-Software   Click Software button to see information. Code version  4.8 System-Reboot Click Reboot
5. Network Configuration   5.1 Network-Interfaces Click Network button to see information.   Edit Ethernet 10/100/100 setting Edit Device IP setting   5.2 Network-WiFi Click Network button to see information.   Edit 802.11 a/b/g/n setting Edit 1x1,2x2 MIMO setting Edit Radio channel setting Edit Radio bandwidth as NT20, HT40  5.3 Network-Switch Click Network button to see information.   Edit Ethernet 10/100/100 setting
6. Antenna information:  Antenna   Peak gain ( dBi ) Model Type   Connector 2400~2483.5MHz 5150~5250MHz 5250~5350MHz 5470~5725MHz 5725~5850MHz UEN-203-RSMA Dipole R-SAM 5.7 dBi 4.35 dBi X X 5.06 dBi

Navigation menu