NORDYNE Furnace/Heater, Gas Manual L0612164
User Manual: NORDYNE NORDYNE Furnace/Heater, Gas Manual NORDYNE Furnace/Heater, Gas Owner's Manual, NORDYNE Furnace/Heater, Gas installation guides
Open the PDF directly: View PDF .
Page Count: 36
Download | |
Open PDF In Browser | View PDF |
Direct Vent (Sealed Combustion) Forced Air Gas Furnaces M2RC Series 90+ Upflow Condensing Furnace M2RL Series 90+ Downflow Condensing Furnace Upflow Downflow Model Model / WARNING: Improper alteration, installation, service, or can cause injury adjustment, maintenance or property Do not try to light any appliance. damage. Refer to this manual for assistance. For additional information consult a qualified installer, the gas supplier. service agency, or Do not touch any electrical switch; do not use any phone in your building, Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. if you cannot reach your gas supplier, call the fire department. Do not store or use gasoline other flammable liquids vapors in the vicinity or of this or any other appliance. Extinguish any open flame. and WARNING: Danger. Only qualified service personnel shall be used to install and provide maintenance to this appliance. TABLE OF CONTENTS General ...................................................... Unit Dimensions ................................. Furnace Airflow Data ......................... Clearances to Combustible Materials 3 3 4 4 Lighting and Adjustment of the Appliance ............................ 23 Electrical Wiring ..................................... 24 Line Voltage Wiring .......................... 24 Low Voltage Wiring .......................... 25 Shipping Weights ................................ 4 Owner's Information ............................... 5 Ventilation ............................................... Installation Requirements ...................... 5 Location .............................................. 6 Start-up and Adjustment ..................... 26 Start-Up Procedure ......................... 26 Shut Down Procedure ..................... 26 Circulating Air Supply ............................ 6 Verifying and Adjusting Firing Rate. Verifying and Adjusting Temperature Rise .......................... Verifying Burner Operation .............. Verifying Operation of the Supply Air Limit Switch .................. Return Air Provisions .............................. 7 Air Distribution Upfiow Systems ........................ 7 Furnace Installation .................. 8 Downflow Furnace Installation ............. 8 Venting and Combustion Air Requirements .......................... 11 Venting Requirements .......................... Vent Table ........................................ Vent Pipe Material ............................ Vent Pipe Length and Diameter....., Vent Pipe Installation ........................ Pipe Routing & Support .................... Horizontal Venting ............................ Vertical Venting ................................ Vent Freezing Protection ................. 11 12 13 13 14 14 17 17 18 Description of Components ................ 28 Location of Major Components._._ '...... 32 21 Wiring Diagram ...................................... 33 Installation/Performance Checklist ......................................... 34 N IFuel Type I_N - Natural Gas Ready L - Propane (LP) Gas Read_ • Home Furnace Series, --B Cabinet Width - 19-3/4" Airflow 16 - 1600 CFM Comfort Model Electrical Code A - 1PH, 60 Hz, 120 VAC RC - Condensing Upflow RL - Condensing Downflow Heating Capacity Input, BTUH (000') Table 1. Model Identification 2 28 Furnace Accessories ............................. 31 M 2 RC.- 080 Application M-Manufactured 27 28 System Operation Information ........... 30 Sequence of Operation .................... 30 Furnace Fails to Operate ................ 31 Gas Supply and Piping ......................... 19 Leak Check ...................................... 20 High Altitude Derate ......................... 20 ............................................. 26 Maintenance ........................................... 29 Combustion Air and Vent System ... 29 Air Filter(s) ....................................... 29 Lubdcation ........................................ 29 ......... Condensate Drain Assembly .......... 29 Blower Compartment ....................... 29 Heat Exchanger and Burner Maintenance .................................. 29 Drainage of Condensate From Furnace ................................ 18 Conversion 26 GENERAL Upflow Furnace Cover Plate Combusbon Exhaust Vent 6 114" Air 23 1'4" -L Inlet J_l Airln_et A/C Coil Box 5,8" -- / --27 Combustion _.: r7 rt Gas Connection 9 n Bottom 1 3/8" Ream Opening -- 2 t,4" 19 314"_ Condensate 4-- Condensata Drain Outlet Drain Outlet Downflow Furnace i Combust;cm Air Inlet Ii RetumAirOpenln '_ i I Exhaul_ , . -- I-3/4- 27 718"-- , _,-_ Y : -_, 10_ _l_ Combustion Air Inlet 24 718" 718" Die Electric Connection "_" 11/2. x 2 tl2 . 1 I/2" T 21 1/2" 21 114"_ t5t/2. k_ i °+,,,,o. 1111llt@ 8UpldyAk O_nm.g (S_ I ? Sl/4' 2 ,(-_ Norton 19 3/4" _1 Supply Air O_0emng Bottom Supply Atr Open nt Figure 1. Unit Dimensions 3 IMPORTANT:READALL INSTRUCTIONS ified service technician periodically check all wiring CAREFULLYBEFOREBEGINNINGTHE connections and service unit as required. INSTALLATION. The M2 sedes gas furnaces are listed drect vent (sealed combustion) forced air furnaces (type FSP) for use with both natural and propane (LP) gases. The M2 furnace series has been certified to the UL 307B standard for use in the United States and to ANSI Z21.47a-CAN/CGA-2.3a1995 for use in the United States and Canada. / WARNING: Do not use this product if any part has been submerged under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been submerged These furnaces may be installed in: under water. / WARNING: Manufactured Homes 2, Recreational Vehicles, Park Models 3. Manufactured Buildings 4. Modular Homes / Buildings The M2 furnace is not to be used for the temporary heating of buildings under construction. Should overheating occur, or the gas fail to shut off, shut offthe manual gas valve to the appliance before shutting off the electrical 1. Model Shipping Weight (Ibs) M2RC - 080A * 16 - B_*) M2RC - 1OOA- 16 - S(*) M2RL - O60A - 16 - B(*) 160 170 170 M2RL - 080A - 16 - B(*) M2RL - 100A - 16 - B(*) A]C Coil Box •Can be N orL 170 175 20 supply. NOTICE: Leave these instructions withthe homeowner. Advise unit owner/user to follow the main_ter]ance rrecommendations outlined. Have a qual- Table 2. Shipping Weights CAPACITIES --Furnace Airflow Data Furnace Furnace input Motor Model No. B_uh Speed High * HP 1/2 M2RO-OSO 80,000 Meal-High Med-Lcw *' Low M2RC-100 100,000 Meal-High " Med-Low _oto; High * M2RL_60 M2R L-089 M2RL-100 1/2 Exkrnal 0.2 0.t CFM 1840 Rise * 1600 1380 1100 43 50 1910 - 1640 1440 53 61 Low 1230 - 60,000 High * Med High Med Low *' 1/2 1620 1450 1255 32 36 42 8_,000 Low High" Med High Med Low _ 1/2 1080 1620 1450 1255 48 43 49 56 L_ 1080 65 High* Meal High " Med Low 1620 1430 1260 54 62 70 100,000 Low 112 1085 • Factorywired cc_ling speed tap • * Factory wired heating speed tap stage Pr,_sure (Inches Water Column} 0.3 0.4 CFM Rise CFM Rise CFM I_se 1780 1560 1350 1050 44 51 1700 1470 1300 1000 47 53 1630 1400 1250 950 1860 1620 1410 1210 1560 54 62 33 1780 1540 1370 1180 1490 57 64 35 1400 1225 1055 1560 1400 1225 1055 37 43 49 45 50 57 67 1350 1180 1030 1490 1350 1180 1030 1555 1375 57 64 1220 1050 72 0.5 CFM Rise 49 55 1550 1350 1190 900 51 58 1700 1480 1320 1140 1430 59 66 . 36 1620 1420 1270 1090 1365 62 70 38 38 44 51 47 52 60 68 1295 1145 1000 1430 1295 1145 1000 40 45 52 49 54 61 70 1240 1105 960 1365 1240 1105 960 42 47 54 52 57 64 73 1485 1330 59 66 1425 1265 62 70 1355 1210 65 73 1170 1015 75 1130 970 1070 935 - NotRecommended NOTE: Datais for operationwfth filter. Table 3. Furnace Airflow Data CLEARANCES TO COMBUSTIBLE MATERIALS This furnace is designed for the minimum clearances to combustible material listed in Table 4. Refer tothe fumace name plate, locatedinside the furnace cabinet, for specificmodel numberand clearance information. Furnace Cabinet Minimum Clearances (Inches} Input Width (Stuh} flnches_ Side Vent Plenum 60,000 19314 O O 0 10 0 1/4 80,000 193/4 O O O 10 O 1/4 1/4 100,000 193/4 0 O 0 19 0 1/4 , 1/4 Back Top* Front** Surfac_ Ductwork within 3 fL of Furnace 1/4 * For Downflow model only. Upflow models can be 1". ** 24 inches is the minimum clearance for servicing. 36 inches is the recommended clearance for service. 4 Table 4. Minimum Clearances to Combustible Materials NOTICE TO INSTALLER Installer is advised to follow carefully all instructions and warnings in this manual to insure maximum performance, safety, and operating efficiency of these appliances. Improper installation may create hazardous conditions, and will void the appliance warranty. OWNER'S INFORMATION About Your Central Furnace System NORDYNE has been involved in the design of products for the manufactured home industry since the first manufactured home or trailer was built. NORDYNE originated the sealed combustion system, which separates the furnace combustion system from the living area of the home and is now a standard for the manufactured home industry. NORDYNE engineers developed the first central heating system and the first central air conditioner for manufactured homes. NORDYNE is dedicated to bringing to its customers the finest heating and cooling comfort possible. NORDYNE constantly seeks to further refine its products to continuously provide exceptional comfort. Manufacturer Warranty, Responsibilities Owner's It is the sole responsibility of the homeowner to make certain the gas furnace has been correctly installed in the home, converted to the proper fuel (LP gas or Natural gas), and adjusted for proper operation. A warranty certificate with full details is included with this furnace. However, NORDYNE will not be responsible for any costs found necessary to correct problems due to improper setup, improper installation, furnace adjustments, improper operating procedure on the part of the user, etc. Some specific examples of service calls which cannot be included in warranty payments are: 1. Converting the furnace to use another type of gas. 2. Repairing duct work in the home found to be faulty. 3. Correcting wiring problems in the electrical circuit supplying the furnace. 4. Resetting circuit breakers, blown fuses or other switches. 5. Correcting problems due to improper gas supply pressure to the furnace. 6. Providing instructional training on how to light and operate the furnace. 7. Correcting any problems caused by installation of an air conditioner, heat pump or other air comfort devices. Follow the instructions in this booklet carefully 8. Revising installation of the furnace flue and this appliance will provide many years _of ......... assembly: .............................. superior performance. 9. Adjusting or calibrating of thermostat. 10. Removing any construction debris whichIf you wish to cool your home automatically with has fallen into flue system. a central air conditioning system investigate the excellent NORDYNE cooling systems availCarefully review these responsibilities with able from your heating and cooling contractor. your manufactured housing dealer, service These systems are designed to work best with company, or gas supplier, so that there will be your NORDYNE furnace and have been careno misunderstanding at a later time. fully engineered to deliver optimal performance when mated with NORDYNE manufactured INSTALLATION REQUIREMENTS home furnaces. Requirements and Codes: The installer must be familiar with and comply NORDYNE also offers water heaters, firewith all local codes and regulations applicable places and ventilating systems specifically to the installation of heating appliances and designed for manufactured housing applicarelated equipment. In the absence of local tions. Ask your manufactured home retailer, your heat nn and coolin,_ contractor or your codes, the installation must conform with these distributor for more information. Write directly instructions and the current provisierfs_'6f_one to the factory (PO Box 46911, St. Louis, MO or more of the following standards: 63146) if you are unable to locate a source for a. Federal Manufactured Home NORDYNE manufactured housing products in Constructions & Safety Standard (H.U.D. your area. Title 24, Part 3280.707[a][2]) b. The Standardfor Manufactured Home c. d. e. Installations (Manufactured Home Sites, Communities, and Set-Ups)ANSI A225.1 and/or CAN/CSA-2240 MH Series). American National Standard (ANSI119.2/NFPA-501C) for all recreational vehicle installations. able and allow the appropriate clearance for your installation. This furnace is certified for use on wood flooring. The furnace must be installed on a solid surface and must be level front to back and side to side. This furnace must not be installed directly on carpeting, tile, or any combustible material other than wood flooring. Downflow models can only be installed on combustible flooring when installed on a Nordyne plenum base (part numbers 901987 through 901993 - see Table 5). Both the upflow and downflow models must be installed with the Nordyne A,'C coil box (part no. 914958). American National Standard (ANSIZ223.1/NFPA-54) and/or CAN/CGA B149 for all gas-fired furnace models. American National Standard (ANSI-C1/ NFPA-70) and/or CSA 22.1 Canadian Electric Code Part 1 for all electrical field wiring. CE g6nerateur d'air chaud dolt 6tre insta]l_ conform6ment aux instructions du fabricant et aux codes Iocaux. En I'absence de code local, respecter la norme ANSI Z223.,1, institule National Fuel Gas Code ou les codes d'installation CAN/GCA-B 149. The plenum attached to the A,'C coil box and the ductwork within 3 feet of the furnace must be installed such that surfaces are at least 1/4" from combustible construction. CIRCULATING The National Fuel Gas Code is available by writing: AmericanNationaIStandardslnstitute,lnc. 1430 Broadway New York, NY 10018 NFPA publications ' are available by writing: National Fire Protection Association Batterymarch Park Quincy, ME 02269 Location The furnace must be installed on a level surface, and as close to the center of the air distribution system as possible. See Figure 1 for overall dimensions to determine the required clearances in hallways, doorways, stairs, etc. to allow the furnace to be moved to the installation point. The furnace must be installed so that all electrical components are protected from water. Minimum clearances to combustible materials are listed in Table 4. Access for positioning and servicing must be considered when locating the unit. 24 inches is the minimum required clearance for servicing the unit. 30 inches is the minimum required clearance for positioning the unit. 36 inches is the recommended clearance from the front of the unit. Please note that a panel or door can be located such that the minimum clearance on the rating plate is satisfied, but that panel or door must be remov- AIRSUPPLY General Plenums and air ducts must be installed in accordance with the Standard for the Installati0n of Air Conditioning and Ventilating Systems (NFPA No. 90A) or the Standard for the Installation of Warm Air Heating and Air Conditioning Systems (NFPA No. 90B). / WARNING: Products of combustion must not be allowed to enter the return air openings of the furnace or the circulating airsupply, Failure to prevent products of combustion from being circulated into the living space can create potentially hazardous conditions including carbon monoxide poisoning that could result in personal injury or death. The floor or platform on which the fumace is mounted must provide sound physical support of the furnace with no gaps, cracks, or sagging between the furnace and the floor or platform. The circulating air ductwork must not be connected to any other heat producing device such as a fireplace insert, stove, etc. RETURN AIR PROVISIONS For floor return systems, the manufactured home manufacturer shall affix a prominent marking on or near the appliance where it can be easily read when the closet door is open. The marking shall read: Upfiow models draw the return air from the base of the furnace. A stand or return air duct must be supplied to the furnace to provide the required return air. Downflow models draw the return air from the top of the furnace. The minimum required clearance to the top of the furnace is detailed on the furnace rating plate. Additional clearance may be required depending upon filter accessibility. For each application, the U.S.A. home manufacturer shall comply with all of the following conditions to have acceptable retum air systems for closet installed forced air heating appliances: a. b. c. d. e. f. g. h. i. CAUTION: HAZARD OF ASPHYXIATION: cover or restrict k. Do not return air opening. Air conditioning systems may require more duct, register and open louver area to obtain necessary airflow. Use NORDYNE's certiduct program to determine proper duct size for A/C. AIR DISTRIBUTION SYSTEMS Regardless of the location, the return air opening into the closet shall not be less For proper air distribution, the supply duct than specified in the appliance's listing. system must be designed so that the static Means shall be provided to prevent pressure measured external to the furnace inadvertent closure by a flat object placed does not exceed the listed static pressure over the return air opening when it is rating shown on the furnace rating plate. located in the floor of the closet (versus the vertical front or side wall). The cross-sectional area of the return Three typical distribution systems are illustrated duct system leading into the closet shall in Figure 2. Location, size, and number of not be less than 390 square inches. registers should be selected on the basis of The total free area of openings in the floor best air distribution and floor plan of the home. or ceiling registers serving the return air duct system must be at least 352 sq. in. At least one register should be located A Single trunk duct [] where it is not likely to be covered by carpeting, boxes and other objects ............................................................ Materials located in the return duct system must have a flame spread classification of 200 or less. This includes trunk duct ] - BJ_ Dual wlcrossover connector-_• _ a-closetdo0r if theefu-rnac_ is"fna-cios_t._ J Noncombustible panshaving 1"upturned flanges are located beneath openings in a floor duct system. Wiring materials located in the return duct,system shall conform_to Articles ,U U U 300-22 of the National Electrical Code (ANSI CI/NFPA-70). Gas piping is not run in or through the Figure 2. Typical Supply Duct System return duct system. Test the negative pressure in the closet FLOOR CAVITY with the air-circulating fan operating at U (depth equal to "X* in F3gure 5 and Table 5) high speed and the closet closed. The t JJJJJJJJJJJJJJJJJJJJJ JJ _ J Ji_ negative pressure is to be no more negative than minus 0.05 inch water I I)J SuPPLYAiR oucT column. -I_! / k h\l x-l--- -----.._ i l ,l Figure 3. Floor Cavity Cut-Out 7 If "X" (Floor can be secured to the furnace using the provided attachment brackets. These brackets are designed to attach the furnace cabinet to the A/C coil box on the sides. To install these brackets, position one bracket on the side of the furnace, so that the locating dimples are in the groove created by the top of the furnace cabinet and the bottom of the A/C coil Use Duct cavity) is: Connector 7/8" (22ram) 901987 2" (51ram) 901988 4 1/4" (108ram) 901989 6 1/4" (159rnm) 901990 8 1/4" (210mm) 901991 10 1/4" (260ram) 901992 12 1/4" (311mm) 901993 Model Table 5. Duct Connectors box. Using the provided self-drilling screws, secure the bracket to the A/C coil box and the furnace. Repeat on the other side of the furnace for the other bracket. C. d. Attach the plenum from the supply duct to the flanges of the A/C coil box. Secure the plenum to the supply ductwork. NOTE: Additional fasteners may be used at rear, sides or through door frame, as desired, to secure furnace to closet or alcove framing. 1-10 li,, , 1 Figure 4. Top View of Duct Connector OPENING TO DUCT DOWNFLOWFURNACE INSTALLATION DUCT CONNECTOR SELECTION DOWNFLOW MODELS FOR a. Determine depth of floor cavity from surface of floor to top of supply air duct (See Figure 3). b. Select appropriate model from Table 5 which matches X-dimension of the floor cavity. To maximize air delivery, remove reducer "C" (see Figure 5) to obtain the largest open area that will fit the duct/ floor construction. WITH pLATE {C) REMOVED OPENING BECOMES 13-1/4" x 13-1/4" INSTALLATION OF THE DUCT CONNECTOR FOR DOWNFLOW INSTALLATIONS Figure 5. Duct Connector UPFLOWFURNACE INSTALLATION a. b. Position the furnace on top of the return air ductwork or return air stand. NOTE: The ductwork or stand must have an opening equal to that of the return air opening of the furnace. Refer to Figure 1 for the proper return air opening size. Secure the furnace to the floor or base once it has been properly positioned. Position and secure the A/C coil box to the top of the furnace. The A/C coil box Required cut-out openings in the floor, ceiling, roof, and/or walls must be carefully located to avoid misalignment of the furnace, combustion air piping, and vent piping (see Figures 14-16). Installation procedures are suggested for typical furnace installations and need not be followed in the exact listed sequence. CUT OUT FLOOR OPENING FOR DOWNFLOW MODELS a. Determine center of closet or alcove (Figure 7). b. Locate center of the floor opening, measured 10" from the rear wall, and mark cut-out measuring approximately 14-1/ 2" by 14-1/2" (+ 1") for model duct connector used (refer to Figures 6 & 7). Figure 6. Cut-Out Locations MOUNTING PLATE REAR WALL f FUEL 1/16TH. LARGER THAN DUCT CONNECTOR Figure 8, Mounting Plate BEND CONNECTOR TABS UNDER DUCT OPENING MOUNTING PLATE FLOOR HOLE Figure 7. Closet or Alcove Floor Cut-Out CUTDUCTOPENING a. b. Place duct connectorthroughthe floor opening with bottom tabs resting on top of the supply air duct. Center duct connector and push back against rear edge of floor opening. Figure 9. Duct Connector c. d. Mark cut-out location (tab area) and remove duct connector. Cut out duct opening 1/4" larger than area marked. 9 TABS -- DUCT TABS _ DUCT 1. INSERT DUCT PLENUM CONNECTOR INTO DUCT CUT-OUT. 2. BEND Bo'n'OM TABS OVER AND ONTO THE UNDERNEATH DUCTSER_CE. Figure 10. Installation of Duct Connector INSTALL a. b. INSTALL e. b. c. FURNACE MOUNTING PLATE Bend tabs on furnace mounting plate upwards 90 ° Place mounting plate (supplied within duct connector) at rear of the floor opening (See Figure 8). DUCT CONNECTOR Place duct connector through the floor opening with bottom tabs extending through the duct opening. (See Figure 9) Secure duct connector to floor. Bend bottom tabs under and up tightly against the supply air duct (See Figure 10). NOTE: The duct connector is designed for use on ducts 12" in width. When using the connector on 12" wide ducts, there may be insufficient clearance to bend the tabs on two sides of the duct connector. In such cases the tabs may be attached to the sides of the duct by using sheet metal screws or other suitable fasteners. (See Figure 11). ALTERNATE ATTACHMENT METHODS This procedure may also be used to install a furnace duct connector to narrow metal ductwork where insufficient clearance prevents bending of the duct connector tabs at the side(s) of the duct. (See Figure 12). 1. Score and cut the top of the metal duct as indicated in Step 1 or Step 2. With Step 1 choice, also cut out the metal from the shaded area "A". 2. 3. Fold the duct flap "B" up, (See Step 3). At the front-to-back of duct run (Area "A"), bend the duct tabs and secure them directly to the duct. Duct Connector "--_ I Duct f Na_ow Duct if ial_e is used to provide a better seal, it should be approved by applicable national or local codes. STEP 1. Figure 11. Narrow Duct Installation STEP 2, Fold Back Flap "B" "' _a Cut Fold _ Rap'B" "O_A" "B" _ Fold Back Rap "B. _-- Fold Back Flap'B" Stapk_ Folded Duct Bend DUCt Connector Tabs Up and Over- (alonglength of duct) Flap (lypl _0,_ide of Du_ Connector Duct STEP 3. 10 S1]EP 4. Figure 12. Alternate Installation I 4. At area"B",bendthe ducttabs up and back over,aroundthe duct connector, (SeeStep3). 5. Fold/form theductflapagainstthesideof theductconnectorand attach as shown, 6. (See Step 4). Use three (3) staples (minimum) on each duct flap OR, if a 2X block/joist is not provided, use two (2) sheet metal screws (minimum) on each duct flap. An alternate attachment method is acceptable, as long as the plenum is securely attached. Tape the duct flap edges with an approved tape for a leak-free joint. INSTALL DOWNFLOW FURNACE a. Prepare the NC coil box as described in the instructionsprovidedwith the coil box. b. Place A/C coil box onto duct connector. c. Slide A/C coil box back until it is firmly against the mounting plate. Mounting plate tabs should be bent upwards so as not to interfere with furnace. d. Secure front with one (1) fastener at each corner through front bottom flange and through the back of the A/C coil box. e. Position the furnace on top ofthe A/C coil box. Ensure that the furnace is properly positioned on the wrapper. f. Secure the A/C coil box to the bottom of the furnace. The A/C coil box can be secured to the furnace using the provided attachment brackets. These brackets are designed to attach the furnace cabinet to the AJC coil box on the sides. To install these brackets, position one bracket on the side of the furnace, so that the locating dimples are in the groove created by the bottom of the furnace cabinet and the top of the A/C coil box. Using the provided self-drilling screws, secure the bracket to the A/C coil box and to the furnace. Repeat on the other side of the furnace for the other bracket. General NORDYNE condensing furnaces must be installed with outdoor combustion air piped directly to the furnace, Codes refer to this type of installation as direct vent, or two pipe installation. Provisions must be made for adequate supply of air for combustion and ventilation. For United States installations, the adequacy of air provisions can be determined by consulting the current version of the National Fuel Gas Code (ANSI Z223.1/NPFA-54). For Canadian installations, requirements are specified in the National Standard of Canada (CAN/CGA B149.1 & .2). Consult local codes for special requirements. NOTE: If the furnace is operated without adequate air for combustion and ventilation, it may not perform properly. Furnace components may be strained by high temperature and could fail prematurely. WARNING: The combustion blocked AND COMBUSTION AIR Fuel Gas Code and all applicable local codes to provide sufficient combustion air for the fumace, VENTING REQUIREMENTS block the combustion pipes. /t',WARNING: VENTED CAUTION: to restrict in any manner, Fumace installation using methods other than those described in the following sections must comply with the National FURNACE REQUIREMENTS Snow must not be allowed or restricted z WARNING: NOTE: Additional fasteners may be used at rear, sides or through door frame, as desired, to secure furnace to closet or alcove framing. VENTING air piping must not be MUST WITH NOT OTHER BE COMMON APPLIANCES. General or air intake or vent This section specifies installation requirements for 2-pipe combustion air piping. The capacity table provided in this section applies to the total sum of vent and combustion air piping lengths. 11 Thesecondensing furnaces are classified as "Category IV" appliances, which require special venting materials and installation procedures. Category IV appliances operate with positive vent pressure and therefore require vent systems which are thoroughly sealed. They also produce combustion condensate, which is slightly acidic and can cause severe corrosion of ordinary venting materials. Furnace operation can be adversely affected by restrictive vent and combustion air piping. Therefore, vent and combustion air piping lengths must conform completely to the requirements of Table 6. b. Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1 orthe CAN/CGA B149 Installation Codes and these instructions. Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition. c. In so far as is practical, close all building doors and windows and all doors between the space in which the appliance(s) connected to the venting system are located and other spaces of the building. Turn on clothes dryers and any other appliance not connected to the venting system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they shall operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers. d. Follow the lighting instructions. Place the appliance being inspected in operation. Adjust thermostat so appliance shall operate continuously. e. Test for draft hood equipped appliance spillage at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle. f. After it has been determined that each The furnace must be vented to the outdoors. It must not be vented in common with any other appliance, even if that appliance is of the condensing type. Common venting can result in severe corrosion of other appliances or their venting and can allow combustion gases to escape through such appliances or vents. Do not vent the furnace to a fireplace chimney or building chase. If removing an existing furnace in a venting system, the venting system may not be propedy sized. To test the vent system with'-the remaining appliances, follow the test outlined below. The following steps shall be followed with each appliance connected to the venting system place in operation, while any other appliances connected to the venting system are not in operation: a. appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas burning appliance to their previous conditions of use. Seal any unused openings in the venting system. APPLICATION PVC, CPVC or ABS DIRECT VENT, DUAL PIPE LENGTH (ft.) with 1 long radius elbow on each pipe.* Inlet/Outlet SCH. 40 Pipe Size 3 == 3 ID Model M2RL 060 50 5O Model M2RCIL 080 90 9O Model M2RC/L 100 90 9O *NOTES 1. Subtract 3.5 ft. for each additional 3" elbow. 2. 3. 4. 5. 6. Two 45 degree elbows are equivalent to one 90 degree elbow. One short radius elbow is equivalent to two long radius elbows. Do not include termination elbows in calculation of vent length. This table is applicable for elevations from sea level to 2000 ft. For higher elevations, decrease vent pipe lengths by 8% per 1000 ft. of altitude. Only the above pipe materials are approved for use with these condensing furnaces. Table 6. Vent Table 12 g. If improperventingis observedduring any of the abovetests, the venting systemmustbe corrected. Proc6dercommesuit pourchaqueappareil raccord6a la tuyauterie d'_vacuation et en _tat normal de fonctionnement; tous les autres appareils raccordes & la meme tuyautede d'_vacuation doivent _tre mis hors service: a. b. c. d. e. f. g. sceller toute ouverture non utilis6e de la tuyauterie d'evacuation s'assurer que la tuyautede d'6vacuation pr6sente des dimensions et une pente horizontale conformes & la norme ANSI Z223.1, intitul_e National Fuel Gas Code ou aux codes d'installetion CAN/CGA B149, ainsi qu'aux pr_sentes instructions. S'assurer que la tuyauterie n'est pas bloqu6e, restreinte, corrodee, qu'elle ne fuit pas et qu'elle ne pr6sente aucun autre defaut potentiellement dangereux. dans la mesure du possible, fermertoutes les pores et fen_tres du b&timent, et toutes les portes entre la piece o_ se trouve I'appareil raccorde _,la tuyauterie d'_vacuation et les autres pieces du b_timent. Mettre en service les s6ccheuses et tout autre appareil qui n'est pas raccord6 _ la tuyauterie d'_vacuation. Faire fonctionner _ regime maximal tout ventilateur d'6vacuation, tel que les hottes de cuisini6re et les ventilateurs de salles de bains. Ne pas mettre en service les ventilateurs d'_t_. Fermer les registres des foyers. respecter les instructions d'allumage. Mettre en service I'appareil & ressai. R6gler le thermostat de mani_re & ce que I'appareil fonctionne sans interruption S'assurer qu'un appareil muni d'un coupe-tirage ne pr6sente aucune fuite ._ rouverture du coupe-tirage apr_s que ie bn31eur principal ait fonctionn_ pendant cinq minutes. Employer la flamme d'une allumette ou d'une chandelle. Apres avoir d6termin_ que tousles appareils raccord_s _ la tuyauterie d'_vacuation evacuent correctment tel que prescrit ci-dessus, rouvdr les portes et les fen_tres et remettre les ventilateurs d'_vacuetion, les registres de foyers et tout autre appareil fonctionnant au gaz _,leur etat de fonctionnement initial. Si un appareil n'evacue pas correctement _, la suite de Pun des essais ci-dessus, corriger la tuyauterie d'6vacuation. Vent Pipe Material Vent and combustion air pipe and fittings must be one of the following materials and must conform tothe indicated ANSI/ASTM standards: Material Schedule 40 PVC PVC-DWV SDR-21 & SDR-26 ABS-DWV Schedule 40 ABS Foam/Cellular Core PVC Standard D1785 D2665 D2241 D2661 F628 F891 Cement and primer must conform to ATSM Standard D2564 for PVC and Standard D2235 for ABS. When joining PVC piping to ABS, use an appropriate solvent cement and procedure per the piping manufacturer's recommendation and ASTM Standard D3138. Vent Pipe Length and Diameter In order for the furnace to operate properly, the combustion air and vent piping must not be excessively restrictive. To ensure this use Table 6, which indicates the maximum allowable piping length for a furnace of specified input rate, when installed with piping of selected diameter and number of elbows. This table applies to the length and number of elbows for each pipe. To use the table, the furnace input rate, the centerline length and the number of elbows on each pipe must be known. Choose the diameter for which the tabulated length is equal to or greater than required. Use of the table is illustrated in the following examples: Example: An 80,000 Btuh furnace is to be installed in a "two-pipe" system with 40 feet of vent piping. There are four elbows, excluding those exterior to the building. Solution: Consulting Table 6, in the dual pipe length column for an 80,000 Btuh furnace, the maximum allowable length for a 3" inlet/ 3" outlet is 90 feet with one elbow. Select 3" pipe. For two additional elbows, deduct 3.5 ft. for each elbow, or 7.0 ft. for a maximum installed vent length of 83 ft. Condensing furnace combustion products have very little buoyancy, so Table 6 is to be used without consideration of any vertical rise in the piping. 13 NOTE: Always use the same or larger size piping for combustion air as is used for the exhaust vent. Vent Pipe Installation Pipe Routing and Support Route piping as directly as possible between the furnace and the outdoors and remember that routing affects pipe size requirements per the preceding section. Locate the combustion air intake and the vent exhaust in the same atmospheric pressure zone - i.e. both must exit the building though the same portion of exterior wall or roof. Vent piping must be sloped upwards not less than 1/4" per foot in the direction from the furnace to the terminal. This is to ensure that any condensate flows back to the furnace (where it can be disposed of through the condensate disposal system). CAUTION: Combustion a corrosive air must not be drawn from atmosphere. _]-he qua!ity of outdoor air must also be considered. Be sure that the combustion air intake is not located near a source of solvent fumes or other chemicals which can cause corrosion of the furnace combustion system. Piping must be mechanically supported so that its weight does not bear on the furnace. Supports must be at intervals no greater than five feet, and at smaller intervals if necessary to ensure that there are no sagging sections to trap water (See Figures 14 & 15). Figure 16 illustrates vent and combustion air pipe sizes exiting the furnace. Transition to the correct pipe size must be done close to the furnace so that the full length of pipe is of proper size. These condensing furnaces have been certified for installation with zero clearance between vent piping and combustible surfaces. However, it is good practice to allow space forconvenience in installation and service. Pipe Couplings at the Furnace The provided rubber couplings should be installed in the combustion air (use 3" diameter coupling) and vent (2" diameter) pipes to allow for servicing. These couplings are designed to fit snugly over the pipe and be secured to the pipes using the provided hose clamps. Use 3" x 2" flexible coupling at furnace on 2" vent pipe and on upflow units use 3" diameter coupling above coil box, as shown in Figures 14 and 15. Refer to figures 14 and 15 for the proper installation of these couplings. Location of Outdoor Terminations Vent and combustion air intake terminations must be located to ensure proper furnace operation and to conform to applicable codes. Figure 13 illustrates necessary distances from the vent termination to windows andbuilding air intakes. In Canada, the Canadian Fuel Gas Code takes precedence over these draft vent termin_d / Air Intet Dite_ Vetlt terminal more than 50,000 Btuh 14 Figure 13. Vent Termination Clearances Upflow Furnace Inlot -- Exhaust _\ I .( 5/8" * '_ See Vent Table I = ! Seal/Cualk Straps or other suitable supports at minimum 5 foot intervals __ _ / at buildin / /_aroundpips g !: _ I I Combustion Air Inlet 7\ I OtfsetwithExhau ! Pips for Adequate _ ' PVC or ABS ' -J ; o=,= E,ha°at Vent 1=" | Wall _ Y_._ MIn, ! Neopren3e "_apl_nt_ r _ ' [ Exhaust Vent _,---' - A/C Coil "------ Normal Snow Level _ Box Flexible 3" x 2= reducer to adapt the 2" diameter vent pips of furnace to the 3" diameter pipe of the vent --Fuma_ Downflow Furnace SealiCautk / See Vent Table 4 I< [ Around Pipe atSu.dth0 \\ Exhaust _lnlat / // 5/8" Straps or Other Suitable Supports at Minimum of I \ I 5 fL intervals i * : Top View ! r r Combustion Offset with Upward Pitch - 1/4" Per Foot Min, i Wall Outlet • Air In_'t Exhaust Pipe for Adequate Dimensioi_al Clearance Exhaust Vent PVC or First Support Should he as Close to Fumace ConnecUon as Possible -Exhauat ASS pipe 3" diamat_ Vent Neoprene Coupling" and 2 Clamps Normal Snow Level Rax{b • 3" x 2 reducer to adapt the 2" diameter vent pipe of furnace to the 3" dLameter pipe of the vent Figure 14. Horizontal Venting * These neoprene couplings are field-supplied and can be used if the installation requires breakable connections in the piping. Note that a maximum of two couplings per pipe are allowed. instructions. Specifically, all minimum distance requirements with respect to termination of the vent piping listed below. The following list is a summary of vent terminal location requirements: 1. The termination must be 12 inches above snow level or grade level whichever is higher. See Figure 17 for alternate method to achieve 12" above snow level. 2. The minimum distance for a direct vent (2pipe) installation) from any door, (openable) window, or air gravity inlet is 1 ft. below, 1 It. horizontally, or 1 ft. above. 3. The vent termination shall be a minimum of 3 ft. above any forced air inlet within 10 ft. 4. The vent termination shall be located at least 4 ft. horizontally from any electric 5. 6. meter, gas meter, regulator and any relief equipment. These distances apply ONLY to U.S. installations. In Canada, the Canadian Fuel Gas Code takes precedence. Avoid areas where condensate drainage may cause problems by dropping on planters or patios, etc. Also ensure that exhaust gases will not impinge on windows or building surfaces, which may be compromised or damaged by condensation. Do not install the vent terminal such that exhaust is directed into window wells, stairwells, under decks or into alcoves or similar recessed areas, and do not terminate above any public walkways. Select the point of wall penetration where the minimum 1/4 inch per foot of slope up can be maintained. 15 Upfiow Furnace Support System on VertJc_atRise blow Rubber Couplinl Support as clolm Joints System wKh flmt support to the furnace as posslbJe Combustion Air Pipe 3" Coupling Box 114" per foot Fumace Furnace Downflow \ 3" diameter Neoprene Coupling* w/2 Clamps Front Furnace Support System on Vertical Rise Below Joints C Support as close System with flint support to the furnace as possible Exhaust Upwa_ Pitch l_'_rFoot Flexible 3" x 2" neducRr to adapt tha 2" diameter vent pipe of furnace to the 3" diameter pipe of the vent Figure 15. Vertical Venting Upflow Furnace Downflow Combustion Air Inlet Pipe Collar Diameter 3" for coupling or reducer Combustion Furnace Air Inlet 3" PVC on 0801t00 models Furnace Top Fureace Top _2" _ 2" PVC Exhaust Vent All Models Useappropriateadaptorfor connectiontofurnace. PVC Exhaust Vent All Models Useappropriateadaptorfor connection to furnace. Figure 16. Furnace Pipe Adaptions 16 CAUTION: For optimal performance vent furnace through wall which experiences exposure to winter winds. the least Horizontal Venting Vent and combustion air intake terminations must be as shown in Figure 18. , WARNING: Ensure thatthe combustion airvent and the exhaust vent are configured as shown in Fig. 18. Improper vent termination can cause recirculation of the flue gases. This may result in furnace vibration. In severe cases, the furnace will cycle, due to the intermittent contact between the flame and the flame sensor. When the above kits are not used the following steps are required: 1. Check the hole size cut through the exterior wall. Insure that the hole diameter is less than the diameter of the couplings to be used. 2. 3. 4. If you note these oscillations occurring, check the vent config u ration. Make sure that the exhaust vent does not have a 90 degree pipe is then cut such that it can penetrate the wall and be held in place by closely fitting standard couplings. The face plates are retained on both sides ofthewall bythe couplings, end the gasket is retained against the wall by the outer face plate. Face plates must be fastened to the wall and the outside one must be flashed as appropriate to prevent entry of water. termination. For horizontal venting, one of the following kits is recommended: Extend the vent pipe through the wall approximately 1" and seal the area between the wall and pipe. Apply couplings to the vent pipe on the interior and exterior sides of the wall to insure the pipe can not be pushed or pulled through the wall. Insure the combustion air inlet pipe has a 90 degree termination elbow, and is pointing downward as shown in Figures 18 & 19. Note that a combustion air intake must be provided with an elbow opening downward. When the vent pipe must exit an exterior wall close to the grade or expected snow level, a riser should be provided as shown in Figure 17. Insulation is required to prevent freezing of this section of pipe. J .. vc.or,zono, J J Exterior Vent 9023750 Mounting Kit For Canadian installations please refer to the Canadian Installation Code (CAN/CGA-B149.1 or 2) and/or local codes. Table 7 describes the maximum length of flue pipe that can travel through an unconditioned space or an exterior space. The total vent length must not exceed the lengths noted on Table 6. The kit consists of two face plates and an insulating gasket to seal the exterior surface. A hole sized closely to the pipe diameter must first be cut through the wall. A short length of Vertical Venting Figure 19 shows the proper installation and clearances for vertical vent termination. The Maximum Flue Pipe Length in Unconditioned and Exterior Spaces 20 0 -20 45 20 10 7O 70 60 _: = Insulation thickness greater than 3/8 inch, based on an R value of 3.5 (ft*°F*hr)/(BTU*in) Table 7. Vent Protection 17 VentConfiguration to Provide 12"Minimum ExhaustVent Op_on B _ height above Snow LeveE. _. 12" Min, 19" Max. wa,, • Out,ide -- _ 1/2" 12" Above Su po. _ Armaflex i _ Insulationor Normally Expected Snow Level Equivalent Figure 17. Alternate Horizontal Vent Installation Figure 18. Exhaust and Combustion Air Pipe Clearances roof penetration must be properly flashed and waterproofed with a plumbing roof boot or equivalent flashing. Termination spacing requirements from the roof and from each other must be per Figure 19. below freezing, i.e., installation within a preexisting masonry chimney; the pipe must be insulated with 1/2 inch thick sponge rubber insulation, such as an Armaflex-type or equivalent. Vent and combustion air piping may be installed in an existing chimney which is not in use provided that: a. Both the exhaust vent and air intake run the length of the chimney. b. The top of the chimney is sealed and weatherproofed. c. The termination clearances shown in Figure 19 are maintained. d. No other gas fired appliances are vented through the chimney. For extremely cold climates or for conditions of short furnace cycles (i.e. set back thermostat conditions) the last three feet of vent pipe can be reduced one nominal pipe size provided that the total vent length is at least 15 feet in length and the vent is sized in accordance with the venting requirements (Table 4) before this reduction isapplied. (Example: 3"to2-1/2") Smaller vent pipes are less susceptible to freezing, but must not be excessively restrictive. Vent Freezing Protection To prevent condensate icing over extended runs of vent pipe exposed to temperatures ; Exhaust Vent's. Concentric Vent Termination A concentric vent termination is approved for use with these furnaces. The kit part number is listed in Table 13. For proper installation of the concentric vent termination, follow the installation instructions provided with that kit. DRAINAGE FURNACE Combustion Air OF CONDENSATE FROM / WARNING: The condensate produced by the fumace m ust be drained. Do not connect a water Exhaust Plumbing Vent Roof Boot ('ryp, Both i drainage hose of the Pipes) A= 12"AboveRoofor SnowAccumulationLevel Figure t9. Vertical Vent Termination 18 supply to the furnace. NOTE: The condensate drain should be protected from freezing when in unheated spaces. Left Side Drain Route to I Routeto mOR Im floor drain. 18.... "HARD" J Drain Tube Route Io condel_sate Clamp (LoosenForStepI) downward "HARD' J (LoosenForSlepI) downward (RetightanforStep 3) slope. Drain Tube (R(_tighten forStep 3) slope. _ Clamp Figure 20. Furnace with Condensate The condensate drainage system is internal to the furnace. The drain may exit either the dght or left side of the furnace cabinet. For a right side drain, simply extend the tubing out of the 7/8" hole in the cabinet (See Figure 20). For a left side drain follow the steps below: 1. Loosen the clamp on the soft exit tube (see Figure 20.) 2. Rotate the soft exit tube (counter clockwise, 180 ° upflow models; clockwise 90 ° downflow models.) 3. Re-tighten the clamp. MAKE SURE CLAMP IS TIGHT TO AVOID LEAKAGE OF CONDENSATE. 4. Route the tubingout ofthe 7/8" hole located 8 inches up fl'om the bottom furnace. The condensate shouid drain from the plastic collector box (location A in Figure 20) as droplets or a small stream. If you notice the furnace has operated formorethan 5 minutes without draining or the red status light on the control board is pulsing a 2-blink code follow the steps below. 1. 2. 3. OR , _ condensate pump. Ksep Remove the collector box soft tube at location A in Figure 20 and insure the exit from the collector box is clear of any debris or obstructions. Replace this tube and insure the fit to the header spout is airtight. Airwill be drawn into the header if this connection is not tight. Check other tube connections along the drain system. Insure that all are air tight. NOTE: Industry research studies indicate that when condensate is routed to an active drain, household detergents, etc., buffer its acidity. If the drain is not actively used or if codes require, pump¸ Keop Drain Trap Assembly obtain a neutralizer kit (usually contains limestone). Proper drains and connections to the condensate tubing are required as NORDYNE cannot be held responsible for water leakage which occurs due to loose hose connections or improperly sealed drain line pipes. GAS SUPPLY AND PIPING General This furnace is equipped for either left or right side gas entry. Typical gas service hook-ups are shown in Figure 21. When making the gas connection provide clearance between the gas supply line and the entry hole in the furnace casing to avoid unwanted noise and/or damage to the furnace. All gas piping must be installed in compliance with local codes and utility regulations. Some local regulations require the installation of a manual main shut-off valve and ground jointunion external to the furnace. The shut-off valve should be readily accessible for service and/or emergency use. Consult the local utility or gas supplier for additional requirements regarding placement of the manual main gas shut-off. In the absence of local codes, the gas line installation must comply with the provisions stated in the Federal Manufactured Home Standard (H.UD Title 24, part 280 and the National Fuel Gas Code (ANSI Z223.1/NFPA54) or (CAN/CGA B149) installation codes. A drip leg should be installed in the vertical pipe run to the unit. Table 8 lists gas flow capacities for standard pipe sizes as a function of length in typical applications based on nominal pressure drop in the line. 19 Typical Left Side Entry - Upflow Roll_ut Burner Viewport Limit °Ourn r Some Utilities °'llll Assembly Off Valve to be 4 to 5 feet Above Floor Require Shut- I F - Ground _ / Automatic Gas Valve / (wdh manuel shut-off) Denotes fieldprovided and installed water column), the furnace must be disconnected from the gas supply piping system to prevent damage to the gas control valve. If the test pressure 1/2 psig (14 in. water be isolated from the the manual shut-off is less than or equal to column), the furnace must gas supply line by closing valve. Leak Check After the gas piping to the furnace is complete, all connections must be tested for gas leaks. To check for leaks use only a soap and water solution or other approved method. component. Typical Right Side Entry - Downflow Denotes fieldprovided and Automatic installed components. Gas Valve (with manual shut-off) ' , Ground J< int Some Utilities UrlioR Burner Roll-Out Lim_ Assembly _, Off Valve to be 4 to 5 feet 1 Above Require Floor Shut- Ii ..... High Altitude Derate The nameplate input rating for the furnaces apply for elevations up to 2,000 feet (610m) above sea level. For elevations over 2,000 feet, reduce the input by 4% for each 1,000 feet above sea level. For example, a furnace applied at an elevation of 5,000 feet should be derated by 20%. See Table 9 describing the correct orifice for derate. NOTE: For Canadian high altitude (2,000 to 4,500 ft.), simply reduce the gas manifold pressure to 2.8" WC for natural gas and 8.5" WC for LP gas without changing the orifices. _-Bumer Viewport Figure 21. Typical Gas Service Connection NOTE: Gas piping must not be run in or through air ducts, chimneys, gas vents, elevator shafts, etc. Compounds used on threaded joints of gas piping must be resistant to the actions of liquefied petroleum gases. The main manual gas valve and main power disconnect to the furnace must be properly labeled by the installer in case emergency shutdown is required. NOTE: The density of air decreases with increasing elevation above sea level. This reduces the quantity of combustion air drawn into the furnace under normal operation and requires the unit be derated by using smaller gas orifices or lower manifold pressure. CAPACITY OF BLACK IRON GAS PIPE (CU, FT, PER HOUR) FOR NATURAL GAS (SPECIFIC i_OMI MAL GRAVITY LENGTH BLACK IRON PIPE DIAMETER - 0.60) OF PIPE RUN _feet) (in. I 1/2 10 130 2D 90 30 75 3#4 280 190 150 1 520 350 285 1 114 1050 730 590 1 1/2 1600 1100 890 40 65 50 55 60 50 70 45 80 40 130 115 105 95 90 245 215 195 180 170 5(0 440 400 370 350 7_ 670 610 560 530 T_e cubicfeetperhourlietedinthetableabove mustbegreeterthan the cubicfeetper hourofgas flowrequiredby thefurnace. CAUTION: Do not use matches, lighters, candles, or other sources of open flame to check for gas leaks. NOTE: When pressure testing gas supply lines at pressures greater than 1/2 psig (14 in. 2O To determine the cubic feet per hour of gas flow required by the furnace, divide the input rate ofthe furnace bythe heating value ofthe gas: Cubic Feet Per HourRequired -- InputTo Furnace (Btu/hr) HeatingValue ofGas (Btu/Cu, Ft.) Table 8. Capacity of Black Iron Gas Pipe (cu. ft. per hour) for Natural Gas (specific gravity = .60) CONVERSION 4. This furnace can be converted from the factoryequipped gas to either natural gas (for LP gas ready models), or LP gas (for natural gas ready models). Conversions must be made by qualifiled service personnel, using only factory authodzed or approved parts. The required conversion orifices are supplied with the furnace. 5. To Remove the Burner Assembly: 1. 2. / WARNING: DO NOT REMOVE ORIGINAL RATING OR DEFACE 3. THE PLATE. 4. CAUTION: 5. 6. The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. 7. 8. To Turn Off Fuel Supply to the Appliance: 1. 2. 3. Set the room thermostat to "OFF" or its lowest temperature setting. Turn OFF the main gas supply to the appliance at the manual valve, outside of the appliance casing. Remove the control access panel / Iouvered door. EXAMPLE Elevation Type of gas Furnace model Odfice as shipped Move the appliance gas valve lever/knob to the "OFF" position. Turn OFF the electrical power to the appliance. Follow the instructions "To Turn Off the Fuel Supply to the Appliance." Disconnect the flame sensor wire from the burner box. Disconnect the igniter wires at the 2 pin plug. This is a locking quick connect and both sides of the lower section must be depressed in order to be separated. Remove the wires from the terminals of the gas valve. Disconnect the rubber pressure tubes from the gas valve and the burner box. Remove the burner access cover plate from the burner box. Remove supply gas piping from the gas valve. Carefully remove the burner assembly fasteners and remove the bumer assembly from the appliance. Keep the fasteners that were removed. Note that the burner box may have hooks near the top and on the right and left hand sides. To remove this type of bumer box, lift the burner box upwards and then remove the box from the unit. 1 3,890 feet Natural M2RC-100A-16-BN #45 Ddll EXAMPLE 2 Elevation Type of gas Furnace model Orifice in Natural to LP Conversion Kit 5,500 feet Propane M2RC-100A-16-BN # 55 drill What burner odfices are needed? What burner odfices are needed? The required input for 3890 feet is 84,000 Btuh or 16% less than the sea level rating of 100,000 Btuh. See Table 8 for natural gas, find the Furnace Model Number and follow across the table for the elevation 2000-4000 column. From the table, choose a #46 orifice. Install a #46 orifice in every burner and check the fidng rate per the VERIFYING AND ADJUSTING FIRING RATE section. The fidng rate in this example must not exceed 84,000 Btuh. The required input for 5500 feet is 76,000 Btuh or 24% less than the sea level rating of 100,000 Btuh. See Table 8 for LP gas, find the Furnace Model Number and follow across the table for the elevation 4000-6000 column. From the table, choose a #56 orifice, install a #56 odfice in every burner and adjust the manifold pressure to 10.0 inches water column. The fidng rate in this example must not exceed 76,000 Btuh. 21 Furnace Model Number Furnace Rating Plate Input No. of Burners Elevation 0 - 2000 Elevation Elevation 2000-4000 4000-6000 Elevation Elevation 6000-6000 8000-10000 M2R(C,L) - (Btuh) Nat LP Nat LP Nat LP Nat LP Nat LP 060A-16-B(* I 60tO00 4 49 56 49 56 50 57 50 57 51 58 080A-16-B(*) 80,000 4 45 55 46 55 49 56 49 56 50 57 100,000 5 45 55 46 55 49 56 49 56 50 57 100A-16-B(*) *canbeNorL Table 9. Approximate Orifice Size for Natural and LP Gases To Remove the Burner Orifices: 1. 2. Remove the four (4) fasteners that secure the gas manifold to the burner box, as shown in Figure 24. Carefully remove the gas manifold assembly from the burner box. Note that the gas manifold assembly consists of the gas valve, the gas manifold, and the orifices. Honeywell Valve OTHER SIDE OF CAP PRESSURE REGULATOR Carefully remove the burner orifices from the gas manifold, as shown in Figure 24. CAUTION: Caution: Do not re-drill the burner odfices. If the orifice size must be changed, only new orifices. Figure 22. Convertible Pressure Regulator Cap use Note: The size of the new orifices that will be installed into the unit will depend upon the type of conversion (sea level or high altitude; natural gas or LP gas), To Convert the Unit to the Alternate Gas 1. 2. 3. 22 Remove the orifice bag from the manifold of the unit. Install the appropriate gas burner orifices into the gas manifold. Remember if installing in the United States at altitudes above 2,000 feet to install the proper orifices, shown in Table 6. When installing the new orifices, DO NOT use pipe joint compound on the orifice threads. Screw the orifices into the manifold by hand until snug to eliminate cross threading, then tighten with a wrench. Before installing an orifice, check the face or side of the orifice for the drill number to ensure that it is the appropriate size. For the conversion to the alternate fuel, the gas valve regulator cap must be turned over, as shown in Figure 22. You will unscrew the cap and reinstall for your installation. After reinstalling the cap, you will be able to read "NAT" for the conversion to natural gas or "LP for the conversion to LP gas. Figure 23. Burner Inspection Burner Orifices Gas Manifold Flame _t ,_;f_iObservatiOn Inlet Tap Inlet , Gas Valve Cover Plate Figure 24. Typical Installation For Sealed Burner Box With Access Cover Plate Reinstallingthe Burner Assembly: 1. 2. Reinstall the gas manifold assembly to the burner box with the four (4) fasteners, which were removed earlier. Carefully reinstall the burner box into the unit. After installing the burner, inspect the alignment of the burners with the heat exchanger tubes. The center of the burners should be aligned with the center of the tubes. 3. Reconnect valve. the gas piping to the gas 4. Reconnect terminals. the wires to the gas valve 5. Reconnect the rubber pressure tubes to the gas valve and the burner box. Reinstall the burner access cover plate. Reconnect the igniter at the 2 position plug. Reconnect the flame sensor wire to the burner box. 6. 7. Pressure Gauge Installation NOTE: For natural gas installations, the incoming gas line pressure at the gas valve inlet must be between 4.5" WC and 10.0" WC. For LP gas installations, the incoming gas line pressure at the gas valve inlet must be between 11 .O" WC and 14.0" WC. This pressure can be checked at the inlet end of the gas valve using a pressure gauge or U-tube manometer, which must be installed according to the manufacturer's supplied instructions. LIGHTING AND ADJUSTMENT 1. Turn ON the gas at the manual valve, outside of the unit. 2. Check all gas connections for leaks with a soap and water solution. If the solution bubbles there is a gas leak which must be corrected. Do NOT use an open flame to check for gas leaks. Turn ON the electrical power to the appliance. Move the gas valve lever/knob to the "ON" position. The lever/knob must be moved to the end of its range of motion to insure the valve is completely open. Use only your hand to push in or turn the gas control valve. Never use tools. 4. 5. 7. Check that the unit ignites and operates properly. Refer to the installation instructions provided with your unit for the normal operating sequence. After the flame ignites, visually inspect the burner assembly to ensure that the flame is drawn directly into the center of the heat exchanger tube, as shown in Figure 23. The end of the flame will be out of sight around the bend of the heat exchanger tube. In a properly adjusted burner assembly, the flame color should be blue with some light yellow streaks near the outer portions of the flame. NOTE: Until all of the air is bled out of the gas line, the hot surface igniter may not ignite the gas. If the ignition control locks out, turn the thermostat to its lowest setting and wait one minute then turn the thermostat to a point above room temperature and the igniter will try again to ignite the main burners. This process may have to be repeated several times before the burners will ignite. Once the burners are lit, check all gas connections for leaks again with the soap and water solution. If the solution bubbles there is a gas leak which must be corrected. Do not use an open flame to check for gas leaks. Adjusting the Manifold Pressure The manifold pressure can be measured by installing a pressure gauge or U-tube manometer to the outlet end of the gas valve as follows: OF THE APPLIANCE 3. . Set the room thermostat to a point above room temperature to begin the heating cycle of the unit. 1. 2. 3. 4. 5. 6. With a 3/16" Allen wrench, remove the manifold pressure tap plug located on the outlet side of the gas valve. Refer to Figure 3 for more details. A fitting, which has a 1/8" NPT pipe thread that is compatible with the pressure gauge or U-tube manometer, must be installed ............ at this point. Install the pressure gauge or U-tube manometer according to the manufacturer's supplied instructions. Set the room thermostat to a point above room temperature to start the furnace. Allow the furnace to operate for three (3) minutes and then check the manifold pressure. Table 10 pressures pane (LP) of fuel and lists the appropriate manifold for both natural gas and progas installations, For the type the altitude of your installation, 23 Manifold Pressure for 0-2000 Feet Above Sea Level Natural Propane Gas (LP) 3.5 10.0 with wire having a minimum temperature rating of 105°C. Refer to the furnace nameplate and Table 8 for electrical requirements. (In WC) Line Voltage Wiring The line voltage (115 volt) to the furnace must be supplied from a dedicated branch circuit containing the correct fuse or circuit breaker for the furnace. See Table 11. An electrical switch should be readily accessible from and within sight of the furnace. See the Wiring Diagram label in the furnace for more details. Table 10. Manifold Pressures for Sea Level determine the required manifold pressure. For Canadian high altitude installations, refer to the "High Altitude Derate" section for more details. COMPLETING 1. 2. THE CONVERSION The furnace cabinet must have an uninterrupted, unbroken ground to minimize injury should an electrical fault condition occur. The controls used in this furnace require an earth ground to operate properly. Acceptable methods for grounding are electrical wire or conduit approved for electrical ground service. Do not use gas piping as an electrical ground. Affix the gas valve conversion label found in the package with the orifices to the unit rating plate. Run the appliance through a complete cycle to assure proper operation. CAUTION: A_ To avoid electric shock, personal injury, or death, turn offthe power at the disconnect or the main service panel before connections. making any ,,/ i Condensing Unit Condensing Unit -Control Box electrical [_ 3Amp Blower Off Tlmlng Fuse R&W For ELECTRICAL WIRING Black _ must Status Light {R,d I• be connected to the thermostat for proper cooling mode _atlon. :_ = FIELD WIRING Low Voltage _ Neutrals Figure 26. Low Voltage Field, Four-wire Heating/Cooling Applications ..... Black - White _ Field Une Voltage Wiring -- Voltage Wiring Factory Line round / Ground Field Supplied Disconnect Within Sight of Furnace i Unused Motor Leads Connections Black _ ___ ___ - _/-hit-e- - ______ _-_ _/hite- Ground 24 Flame Signal Light {Yell_ i 0 Thermostat Panel Connector Black_H_ot)J_] (Ground) ..... Field Supplied Panel _ ite (Neut-_l_ ..... Only NOTE:Ttla "_ terminal on the UTiEC control board For Canadian installations electrical connections and grounding must be done in accordance with the current Canadian Electrical Code (CSA C22.1 Part 1) and/or local codes. If any of the odginal wire as supplied with the furnace must be replaced, it must be replaced F_/ddS_P pwliied ..... Heating Room General Electrical connections must be made in accordance with all applicable local codes and ordinances, and with the current revision of the National Electric Code (ANSI/NFPA 70). T_N "" _ Junction Box (may be internal or external to the furnace). These connections can be made in the field supplied disconnect at the furllace. Figure 25. Line Voltage Field Wiring Furnace Cabinet Width Input (Btuh) 60,000 80,000 100,000 Nominal Electrical Maximum (in,) Supply Operating Voltage 19.75 19.75 19,75 115-60-1 115-60-1 115-60-1 127 127 127 Thermostat Minimum Maximum Operating Furnace Voltage Amperes 103 103 103 Wire Gauge 9.7 9.7 9.7 Recommended 2-wire {heating) 24 22 20 18 55 ft. 90 ft. 140 ft. 225 ft, Minimum Wire Maximum Fuse or Circuit Gauge Breaker Amp_* 14 14 14 15 15 15 Thermostat Wire Length 4 or 5-wire {cooling) 25 ft. 45 ft, 70 ft. 110ft. * Time-delayfuses or HACR-typecircuitbreakersare required. Table 11. Electrical Data NOTE: Proper line voltage polarity must be maintained in order for the control system to operate correctly. Verify that the incoming neutral line is connected to the white wire and the incoming "hot" line is connected to the black wire in the furnace junction box. The furnace will not operate unless polarity and ground are properly connected. See Figure 25. CAUTION: Label all wires when servicing can cause operation. prior to disconnection controls. Wiring errors improper Verify proper operation and dangerous after servicing. ATTENTION: Lors des op6rations d'entretien des commandes, 6tiqueter tous les files avant des les d6connecter. Toute erreur de c&blage peut 6tre danger et de panne. S'assurer rappareil du ben une source foncUonnement de for heating only (two-wire) and heating/cooling (four-wire) applications. The recommended minimum wire gauge for thermostat wiring is shown in Table 11. The thermostat must not be installed on an outside wall or any other location where its operation may be adversely affected. Adverse affects include radiant loading from fireplaces, sunlight, or lighting fixtures, and convective loading from warm air registers or electrical appliances. To check the heat anticipator setting either: 1. Add the current draw of the system components; or 2. Measure the current flow on the thermostat R-W circuit after the circulating blower motor has started. Set the heat anticipator according to the thermostat manufacturer's instructions for heat anticipator settings. VentilAire Bracket de apr_s tout entretien. Low Voltage Wiring Install the thermostat per the manufacturer's instructions. The low voltage (24 volt) connections from the thermostat are made at the terminal strip on the control board in the furnace. See Figure 26 for the proper connections Figure 27. Ventilation Bracket 25 VENTILATION Ventilation must be provided for homes built to HUD Manufactured Homes Safety and Construction Standards. This ventilation can be supplied by the VentilAire III or VentilAire IV accessories (see Table 13). Alternate means to provide the ventilation air must meet the requirements of all applicable local and federal codes. For downfiow models, a bracket is supplied with the furnaces to allow the use of the VentilAire III or VentilAire IV accessories. The bracket is installed on the right hand side at the top of the cabinet, as shown in Figure 27. The bracket can be fastened using the self-drilling screws supplied with the unit. For upfiow models, the means to provide the required ventilation must be incorporated into the upflow furnace base or the return air ductwork to the furnace. For installation of the VentilAire III or IV, follow the instructions provided with the VentilAire kit. START-UPANDADJUSTMENTS General Prior to start-up, verify that: 5. The blower door is in place, closing the door switch in the line voltage circuit. 6. The gas line has been purged and all connections are leak tight. Start-Up Procedure 1. Set the thermostat to the lowest setting. 2. Close the disconnect(s) voltage to the furnace. 3. Follow the procedures given on the operating instructions label attached to the furnace. 4. Set the thermostat above room temperature and verify the sequence of operation. (See the SEQUENCE OF OPERATION.) 5, After the furnace has run for approximately five minutes, set the thermostatbelow room temperature and verify steps 9 - 11 of the SEQUENCE OF OPERATION. Shut Down Procedure In the event that the furnace must be shut down, follow this procedure: 1. The line voltage power leads are securely connected, that the polarity of the connections is correct, and that the furnace is properly grounded. Set the room thermostat to "OFF" or its lowest temperature setting. Turn OFF the main gas supply to the appliance at the manual valve outside of the appliance casing. 2. . to provide line , Remove the control access panel / Iouvered door. 2. The thermostat wires (R, W, Y, and G) are securely connected to the correct leads on the terminal strip of the circuit board. 3, The natural gas line service pressure must not exceed 10.0 in. water column (0.36 psig), and must not be less than 4.5 in. water column (0.16 psig). For LP gas the line service pressure must not exceed 14 in. water column (0.51 psig), and must not be less than 11.0 in. W.C. (0.40 psig). Verifying and Adjusting Firing Rate The firing rate must be verified for each installation to prevent over-fldng the furnace. The roll-out and vent safety manual reset switches are closed. If necessary, press the red button to reset a switch. See Figure 31 for location. DO NOT install a jumper wire across a switch to defeat its function. If a switch reopens on start-up, DO NOT reset the switch without identifying and correcting the fault condition which caused the switch to trip. Use the following procedure to determine the firing rate: 4. 5. 4, 26 Move the appliance gas valve lever/knob to the "OFF" position. Turn OFF the electrical ....._lSpli_+n_:e. power to the NOTE: The firing rate must not exceed the rate shown on the furnace rating plate. At altitudes above 2000 ft. it must not exceed that on the rating plate less 4% for each 1000 ft. 1. Shut off all other gas fired appliances. GAS FLOW RATE (CUBIC FEET PER HOUR) TIME FOR ONE REVOLUTION (SECONDS) 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 CUBIC FEET PER REVOLUTIONOF METER 1 150 138 129 120 113 106 100 95 90 86 82 78 75 72 69 67 64 62 60 58 56 5 750 692 643 600 563 529 500 474 450 429 409 391 375 360 346 333 321 310 300 290 281 10 1500 1385 1286 1200 1125 1059 1000 947 900 857 818 783 750 720 692 667 643 621 600 581 563 TIME FOR ONE REVOLUTION (SECONDS) 80 82 84 86 88 9O 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 CUBIC FEET PER REVOLUTIONOF METER 1 5 10 45 225 450 44 220 439 43 214 429 42 209 419 41 205 409 40 200 400 39 196 391 38 191 383 38 188 375 37 184 367 36 180 360 35 35 34 33 33 32 32 31 31 30 176 173 170 167 164 161 158 155 153 150 353 346 340 333 327 321 316 310 305 300 Table 12. Gas Flow Rate 2. 3. Start the furnace and allow it to run for at least three minutes. Measure the time (in seconds) required for the gas meter to complete one revolution. 4. Convert the time per revolution to cubic feet of gas per hour using Table 12. 5. Multiply the gas flow rate in cubic feet per hour by the heating value of the gas in Btu per cubic foot to obtain the firing rate in Btuh. Example: Time for 1 revolution of a gas meter with a 1 cubic foot dial = 40 seconds. From Table 11 read 90 cubic feet per hour of gas. Heating value of the gas (obtained from gas supplier) = 1040 Btu per cubic foot. clockwise to increase pressure or counterclockwise to reduce pressure. Replace the regulator cap after adjustments are complete. Verifying and Adjusting Temperature Verify that the temperature rise through the furnace is within the range specified on the furnace rating plate. Temperature rises outside the specified range could result in premature heat exchanger failure. Place thermometers in the return and supply air stream as close to the furnace as possible. The thermometer on the supply air side must be shielded from direct radiation from the heat exchanger to avoid false readings. Adjust all Timing 24 V I _N Firing rate = 1040 x 90 = 93,600 Btuh. Ra_ 6, 7. Rise Signal Relatively small adjustments to the firing rate can be made by adjusting the gas manifold pressure. See the "High Altitude Derate" section for additional information on firing rate at elevations above 2000 ft. The gas valve regulator is set at a nominal value of 3.5 in, water column for use with natural gas. The manifold pressure must be set at 10.0 in. water column for use with LP gas. To adjust the manifold pressure, remove the regulator cap and turn the adjusting screw Cornm_ lead8 NeUVldll UnuoedMOlo_ E_c_cnlc I _._ ..... > 4 e- _--° ;= ._,_ Figure 28. Blower Speed Tap Location 27 registers and duct dampers to the desired position and run the furnace for fifteen minutes before taking any temperature readings. The temperature rise is the difference between the supply and return air temperatures. For typical duct systems, the temperature rise will fall within the range specified on the rating plate with the blower speed at the factory recommended setting. If the temperature rise measured is outside the range specified, it may be necessary to change the blower speed. Lower blower speeds will increase the temperature rise and higher blower speeds will decrease the temperature rise. The furnace is equipped with a multispeed motor. Heating and cooling speed selection is made by moving the leads on the integrated control board located in the furnace. The wiring diagram on the furnace and Figure 28 showthe speed taps for adjusting motor speed. If it is desired that the blower operate at the same speed for heating and cooling, tape off the terminal of the unused blower wire. Install the jumper wire, found in the plastic instruction bag, across the HEAT and COOL taps on the control board. Reconnect the desired blower tap to the piggyback quick connect. The blower control is designed to start the circulating air blower 30 seconds after the gas valve is opened. The blower control is factory wired to turn the blower motor off 120 seconds after the gas valve is closed. This timing can be changed using the BLOWER OFF timing switch opposite the terminal block on the control board (See Figure 28). Verifying Burner Operation To verify operation of the burners, make sure that the blower compartment door is in place and that there is power to the furnace. Set the thermostat above room temperature and observe the ignition sequence. The flame can be observed through the small clear window on the burner box. The burner flame should carry over between all burners. The flames should be blue, without yellow tips. Flames should extend from each burner without lifting, curling, or floating. After veri_ing ignition, set the thermostat below room temperature and verify that the burner flame extinguishes completely. Verifying Operation of the Supply Air Limit Switch To verify operation of the supply air limit switch, make surethatthe blower dooris in place and that 28 there is power to the furnace. Completely block the retum airflow to the furnace by installinga close-of[ plate in place of or upstream of the filter(s). Set the thermostat above room temperature and verify that the Sequence of Operation is as described in these instructions. The supply air limit switch should function to turn off the gas valve within approximately five minutes. The circulating air and combustion blowers should continue to run when the supply air limit switch opens. Remove the close-off plate immediately after the supply air limit switch opens. If the furnace operates for more than five minutes with no return air, set the thermostat below room temperature, shut off the power to the furnace, and replace the supply air limit switch. DESCRIPTION OF COMPONENTS Figure 31 shows the location of each of the functional components described below. If any component of the furnace must be replaced, use only factory authorized replacement parts. Contact your distributor for the approved replacement parts. Flame Sensor - The flame sensor acts to prove that flame has carried over from the igniter to the opposite end burner. If no flame is sensed, the furnace will be shut down automatically. Gas Valve - The gas valve controls the flow of gas to the burners. When the gas valve is energized it automatically opens and regulates the gas pressure in the manifold. Pressure Switch - The pressure switch verifies that the inducer is drawing the combustion gases through the heat exchanger. It also senses a blocked condensate drain condition. Vent Pressure Switch (Downflow models only) - The vent pressure switch reacts to blockage in the vent or combustion air piping. Supply Air Limit Switch - The supply air limit switch prevents the air temperature leaving the furnace from exceeding the maximum outlet air temperature. Vent Safety Switch - The vent safety switch shuts the furnace down if the outlet flue gas temperature increases above 160°F, This switch protects the plastic flue system and the inducer from over-temperature conditions. FlameRoll-OutSwitch - This switch provides flame roll-out protection to the furnace and combustion air inlet pipe. MAINTENANCE It is recommended that the furnace be checked yearly. At a minimum, this check should include the following items: / WARNING: To avoid electric shock, personal or death, turn off the power injury, at the disconnect or the main service panel before performing any maintenance. / WARNING: Holes in the vent pipe or heat exchanger can cause products of combustion to enter the occupied space. Replace the vent pipe or heat exchanger if leaks are found. Failure to prevent products of combustion from being circulated intothe occupied space can crate potentially hazardous conditions, including carbon monoxide poisoning, that could result in personal injury or death. Combustion Air and Vent System Check the combustion air and vent pipe to ensure that it is not damaged, corroded or blocked by debris. Any damaged section of vent pipe must be replaced, and any obstruction or blockage must be removed prior to operating the furnace. Air Filter(s) An air filter is supplied with the furnace as shipped from the factory. Filters should be changed or cleaned monthly during the heating season. New or newly renovated homes may require more frequent changing until the construction dust has been removed. For the upflow model, the air filter is located underneath the blower in the blower compartment. To remove the filter, first remove the lower door. Then, slide the filter backwards until the edge of the filter clears the front flange of the furnace. Lift the filter up over the flange and then remove. Reinstall the filter in the reverse manner. Ensure that the filter is centered over the return opening of the furnace, and is captured by the fastener at the rear of the furnace. For the downflow model, the filter is at the top of the furnace. The filter can be removed by lifting the filter upwards and out of the opening. Reinstall the filter in the reverse manner. Ensure that the filter is securely held by the braces on either side of the return air opening. /t WARNING: Never operate the furnace without a filter in place. Dustand lint in the retum aircan build up on internal components, resulting in loss of efficiency, equipment damage, and possible fire. Lubrication The bearings in the circulating air blower motors are pre-lubricated and sealed at the factory. No further oiling of the bearings is required for the life of the motor. Condensate Drain Assembly Be sure the condensate lines are free and open (i.e. avoid kinking hoses). Also make sure all hose clamps are tight to avoid drawing air into the system. Blower Compartment The blower compartment should be cleaned monthly during the heating and cooling seasons to remove any dirt and lint that may have accumulated in the compartment or on the blower and motor. Dirt and lint can create excessive loads on the motor resulting in higher than normal operating temperatures and shortened service life. Heat Exchanger and Burner Maintenance The furnace should operate for many years without excessive soot buildup in the flue passageways, however, the flue passageways, the vent system, and the burners should be inspected and cleaned (if required) by a qualified service technician annually to ensure continued safe operation. Particular attention must be given to identify deterioration from corrosion or other sources. 29 SYSTEM OPERATION INFORMATION General Proper maintenance is most important to achieve the best performance from a furnace. Follow these instructions for years of safe, trouble free operation. Do not place combustible materials on or against the furnace cabinet or the vent pipe. Do not store gasoline or any other flammable vapors and liquids in the vicinity of the furnace. Change or replace the air filters monthly during any period when the circulating blower is operating regularly. Always replace the doors on the furnace after servicing. Do not operate the furnace without all doors and covers in place. Avoid operating the furnace when windows and doors are open. Be sure that the thermostat is properly installed and is not being affected by drafts or heat from lamps or other appliances. Sequence of Operation Operating sequences for the heating, cooling, and fan modes are described below. Refer to the wiring diagrams (Figures 31 and 32) and the low voltage field wiring diagram (Figure 26) for more details. Heating Mode: 1. On a call for heat the thermostat closes, applying 24 VAC to the W terminal on the control board. 2. The control board checks for continuity on the 24 VAC limit control circuit (overtemperature limit switch, flame rollout switches and blocked vent switch in series)., If an open limit is detected the control board will energize the inducer and the conditioned air blower. All other system functions will be inoperable until the limit circuit closes. While the limit is open, the red LED will pulse at a rate of 1 blink per unit time. 3. The furnace control checks for continuity across the pressure switch (24 VAC). If the pressure switch is closed the heat 3O 4. 5. 6. mode sequence will not continue. If it remains closed for 10 seconds the red LED will blink 3 times repetitively until the fault condition clears. The inducer is energized. The pressure switch will close. If the pressure switch does not close after 10 seconds the fault LED will blink 2 times repetitively and the inducerwill continue to run until the switch is closed. The inducer will pre-purge for 30 seconds and then the igniter will start its warm-up as follows: Initial Power up: After 30 seconds of igniter warm-up the gas valve (24 VAC) will then open. The igniter circuit will stay energized for 3 seconds after the gas valve opens. After Initial Power up: The control has a programmed adaptive ignition feature which varies the warm-up period as follows: If ignition is successful the warm-up is reduced by 3-seconds on each subsequent call for heat until ignition failure occurs. Upon ignition failure, the warm-up is _ by 3-seconds on the next try. If successful, the timing remains fixed at this level. In general, whenever ignition failure occurs the warm-up interval is increased by 3-seconds on the next try. And if successful, it remains there. Minimum and maximum warm-up time limits are set at 6 and 54-seconds, respectively. 7. The furnace control must prove flame via the flame sensor 5 seconds after the gas valve opens. If flame is sensed, all burners are on and the igniter cools off. If no flame is sensed, the gas valve closes immediately and the inducer continues to run. A second trial for ignition (step 6) begins if no flame is sensed. On the fifth try for ignition, the furnace control is locked out and the red LED will blink 4 times repetitively. The thermostat must be opened for at least ten seconds to reset the furnace control after a lock out. Otherwise, the furnace will attempt another ignition sequence in 1 hour. 8. The furnace control energizes the circulating air blower on the heating speed 30 seconds after the gas valve circuit is energized . 9. When the thermostat has been satisfied, gas valve is de-energized. 10. The inducer is de-energized after a 30second postpurge. 11. Thefurnacecontrolkeepsthecirculating air blowerenergizedfor 120 seconds (factoryset)or 60, 90, or 180seconds (fieldadjustable). (SeeFigure28.) 12. Abnormal conditions: Ifa limitopensduring operation, the inducerandcirculating air blower continue to operate. The gas valve is de-energized immediately. The blowers continue to operate until the limit closes. When the limit closes the inducer blower is de-energized immediately. The circulating air blower continues to operate for the specified delay (factory set at 120 seconds). Cooling Mode: 1. On a call for cooling the thermostat closes, applying 24 VAC to the G and Y terminals on the furnace control. This closes the compressor contactor. 2. The furnace control energizes the circulating blower (115 VAC) on the cooling speed. 3. When the thermostat is satisfied, the G and Y terminals on the control board are de-energized opening the compressor contactor. 4. The circulating air blower is de-energized after a 90-second delay. Fan Mode: 1. On a call for fan operation, the thermostat applies 24 VAC to the G terminal on the furnace control board. 2. 3. If the furnace locks out after 5 attempts for ignition, it will try again every hour ifa call for heat remains. If the inducer and circulating air blowers are operating, and items 1 through 8 have been checked, press the red reset button on the vent safety switch. (See Figure 30.) If the furnace operates after depressing the reset button, contact a qualified service technician to identify and repair the problem. If furnace continues to not operate, depress the red reset buttons on the flame roll-out switch. If the furnace operates after depressing the reset button, contact a qualified service technician to identify and repair the problem. FURNACE ACCESSORY Kit KITS Order Number Fossil Fuel Kit 914762 A/C Coil Box 914958 Sloped Roof VentilAire IIt Kit 914098 Sloped Roof VentilAire IV Kit 914229 Soffit VentilAire Kit 917201 Concentric Vent Termination Kit for horizontal and vertical venting) 904176 (3 Inch) 904177 (2 Inch) Horizontal Exterior Vent Mounting Kit 2"PVC 902373 3"PVC 902375 Neutralizer Kit - All Models 902377 Table 13. Accessory Kits The circulating air blower is energized immediately on the heating speed. If the furnace is operated in the continuous ON position at the thermostat and is then switched to AUTO, the circulating blower will operate for a specified delay (factory set at 120 seconds). Furnace Fails to Operate If the furnace does not operate check the following: 1. Is the thermostat operating properly? 2. Are the blower compartment door(s) in place? 3. Is the furnace disconnect closed? 4. 5. 6. 7. 8. Has the circuit breaker tripped or the control board fuse burned open? Is the gas turned on? Are any manual reset switches open? Is the filter dirty or plugged? Is the flame sensor coated? (Remove and clean with emery cloth.) 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Upflow Furnace Manh_old Flame Sensor (Not Shown) Gas Valve Roll-Out Limit Switch (155°F) Pressure Switch Control Board, Integrated Blower Door Switch Vent Safety Limit Switch (160°F) Transformer Limit Switch Blower Assembly Inducer Blower (with gasket) J Trap Hard Tube In-Line Drain Assembly Burner Box Assembly (NaL and LP Gas Ready) Header Outlet Box Cased CoilWrappar Filter (I 8 5/8 x 26 1/2 x 114)(Not Shown) Attachment Bracket Turbulator (Not Shown) Coupling Neoprene Orifice, Inducer (Not Shown) Inshot Bumer (Not Shown) Natural and LP Gas Orifice (Not Shown) Igniter (Not Shown) Heat Exchanger Assembly (Not Shown) Capacitor Assembly, I0 MFD, 370V (Not Shown) Blower Wheel CCW (Not Shown) Motor - 1/2 HP (4 Speed) (Not Shown) Access Doors, Set (Not Shown) Man_oU DownflowFurnace Flame Sensor (Not Shown) Gas Valve Roll-Out Limit Switch (155=F) Pressure Switch Integ rated Control Board Blower Door Switch (Not Shown) Vent Safety Limit Switch (160°F) Transformer Limit Switch BlowerAssembly Inducer Blower (with gasket) JTrap HardTube In-Line Drain Assembly Burner BoxAssembly Header OuUet Box Cased CoilWrapper Filter (18 x 20 x 1) (Not Shown) VenUlAire Bracket Attachment Bracket Turbulator(Not Shown) Auxiliary Limit Switch (120 °) (Not Shown) Inducer Orifice (Not Shown) Inehot Bumer (Not Shown) Natural and LP Gas Orifice (Not Shown) Igniter (Not Shown) Heat Exchanger Assembly (No1Shown) Capacitor Assembly, 10 MFD, 370V (Not Shown) Blower Wheel CCW (Not Shown) Motor- 112HP (Net Shown) Access Door (Not Shown) Figure 30. Location of Major Components 32 / Legend Field Wiring Fa_owWidng: LowVoltage -High Voltage _-- FAULT CONDITION Power On LIGHT ON 1 FLASH Umlt Circuit Open or External Load On "W" Pressure Switch Stuck Open 2 FLASHES Pressure Switch Stuck Closed 3 FLASHES 4 FLASH ES Ignition Failure (Check Ground) tt5 VAC & Neutral Reversed or .o Ground 5 FLASHES False Flame or Gas Valve Relay Shorted Power Off FAULT CONDITION Low Flame Sensor Signal Flame Present Continuous OFF FLAME YELLOW LIGHT Continuous Flash ON If anyof the originalwire as suppliedwith the fumace must be replaced, itmust be replaced with wiring material having a temperature rating of at least 105 ° C. Use copper conductorsonly. WD#710062A Figure 31. Upflow and Downflow Furnace Wiring Diagram 33 INSTALLATION/PERFORMANCE CHECK LIST LOCATION CITY STATE INSTALLER CITY STATE UNIT MODEL NUMBER UNIT SERIAL NUMBER Minimum Clearances per Table 3? Are Flue Connections tight? Electrical Connections tight? Is there Proper Draft? Line Voltage Polarity correct? Is Vent free from restrictions? Volts Supply Voltage: Blower Motor HP: Is the Filter(s) secured in place? Is the Filter(s) clean? FUEL TYPE: Natural Gas __ LP/Propane Has the Thermostat been calibrated? Gas Piping Connections leak-tested? __ Gas Line Pressure: Is the Thermostat level? Is the Heat Anticipator Setting correct? __ (in. water column, with furnace operating) Manifold Pressure: (in. water column, with furnace operating) Is there adequate fresh air supply for combustion and ventilation? Furnace Input: (Btuh) _ Supply Air Temperature: (° F) Return Air Temperature: (°F) Temperature (° F) 34 Rise: Has the Owner's Information been reviewed with the home-owner? Has the Literature Package been left near the furnace? 35 Ill IIIIIilll IIIlllllf IIIII 708120B 708120B (Replaces 708120A) O'Fallon, MO NORDYNE Specifications and illusb'ations subject tochange without notice and without inclJrring obligations, Printed in U.S.A. (_,o_)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 36 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 15:53:30 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools