Nedap N V INVEXS170 Inductive Proximity Card Reader User Manual manual

N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Proximity Card Reader manual

Contents

manual

Download: Nedap N V INVEXS170 Inductive Proximity Card Reader User Manual manual
Mirror Download [FCC.gov]Nedap N V INVEXS170 Inductive Proximity Card Reader User Manual manual
Document ID1741790
Application IDaAbncqakSOx6sbY4dG5WCg==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize145.02kB (1812755 bits)
Date Submitted2012-07-11 00:00:00
Date Available2012-07-12 00:00:00
Creation Date2012-02-23 11:42:25
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2012-07-09 14:34:26
Document Titlemanual
Document CreatorMicrosoft® Office Word 2007

®
Invexs 170 readers
Mifare Nedap dual technology readers
Installation sheet
GENERAL
The Invexs 170 reader series is capable of reading
(simultaneously) Nedap, Mifare and DESFire credentials due to
its dual reader technology. The Invexs can read Mifare,
DESFire and Nedap cards, and is equipped with keypad and /
or a display.
The Invexs output can be set to either Wiegand, XS RF
modulation or RS485 protocol (plain or encrypted)
Functionality and output are determined by the configuration of
the Invexs reader. The configuration is defined using the
programm AEreco, and deployed by the configuration card or
via AEmon. (More information about configurations can be
found in ConvexsInvexs_InstallGuide_E.)
Three LED’s (red, green, blue) and beeper are included (display version has no LED). Ciphers of the
keypad versions light up after activation, so when not active the ciphers are not visible.
Back panel is available in two colours, black and white (e.g. MNK170B, MNK170W)
20.3
6.8
4.8
DIMENSIONS
Dimensions: 171 x 75 x 25 mm.
4 mounting holes available at 52 x
120 mm
0.5
Cable outlet: 40 x 40 mm
40
170.5
120
40
52
1.5
75.2
24.5
MOUNTING PROCEDURE INVEXS
For mounting the Invexs, the back plane must be placed on the wall first.
For removing the back plane from the Invexs, unscrew the two screws (1) at
the bottom of the Invexs and push the front cover up (2). Mount the back
Push up
plane using the 4 holes.
Connections must be made on the connector on the backside of the front.
After making the connections, replace the front and tighten up the two screws
at the bottom of the Invexs.
Un screw
Date : 23 February 2012
Version 5
Part.no.: 5265800
This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no licence under any patent or other right,
nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is
not to be reproduced in any way, in whole or in part, without the written consent of the publisher.
© Nedap N.V., IDEAS P.O. Box 103 NL-7140 AC GROENLO The Netherlands
Page 1 of 4
Invexs 170 readers
CONNECTIONS
Invexs is not hot-swappable, so when making or changing connections power must be switched Off.
Invexs without display
Invexs
Function
10
Power /
XSMOD
POWER GND/Shield
A (-)
B (+)
D0
D1
BEEP
UL*
GND
NA*
Power in (10-30VDC) /
XS modulator (120kHz)
Power Ground
RS485
RS485
Wiegand Data 0
Wiegand Data 1
Beep input
UL led input
Led Common Ground
NA led input
10
Invexs with display
10
Remark:
Cable shield must be connected to Power GND of Convexs (A2) and GND of external device
(or metal case).
If connected to a 120kHz RF device (AEOS Nedap reader AEpack or XS device) the power is
supplied via the Convexs adapters (AX1014 for AEpacks, AB350 for XS devices). Existing
antenna cabling can then be reused for connecting the ConveXS.
UL*,NA* and BEEP are Open Collector to GND.
If the Convexs adapters are used, the original UL and NA signals are
UL*/NA* / BEEP
converted to the UL* and NA*.
GND
LED INDICATORS INSIDE
There are two LED’s available: Blue for Status (of application), Green for Identification (both visible
through two small holes at the back side)
ID (green)
Blinking Card detected
Slow blinking
Fast blinking
2 short flashes
3 short flashes
ST: STATUS (blue)
Application running (operating)
Downloading or error during loading
Application present but not active
No application present
LED INDICATORS FRONT
At the front a three colour LED is positioned at the middle of the Invexs
Depending of the used configuration the function of these LED’s can differ:
Green LED:
Card is been authorised (UL led)
Red LED:
Card is not authorised (NA led), controller is stand-by
Blue LED:
Blinks fast:
No configuration is availabele at this Invexs (present Configuration
card or load Configuration first).
Continuously ON: Determined by configuration: E.g. Reader stand-by.
(Blue LED is activated if UL is OFF and NA is more than 1 sec OFF)
Remark:
Function of LED’s and Beeper is controlled by used application settings of Invexs. Green and Red
LED can be controlled by hardware signals (Connector 8 and 10) or RS485NR, Blue LED
indirectly by UL and NA, if this setting is activated (configuration).
Beeper can be controlled by hardware signal (Connector 7), RS485NR or software (configuration).
© Nedap N.V.
Invexs 170 readers Installation sheet
Page 2 of 4
Invexs 170 readers
FIRMWARE
Pay attention that the firmware loaded in the Invexs together with the Invexs type and configuration
determines functionality and protocols. For the Invexs with screen contact Nedap.
Default (from factory) the Invexs handles the credentials on several ways simultaneously:
XS cards as:
RS485NR, RF badge
Mifare cards (CSN) as: RS485NR, RF data
SYSTEM CONFIGURATIONS (how to connect Invexs readers)
AEOS RS485 interface
Wiegand interface
1 23
56
C8
09
23
75
86
To APx003 readers with RS485 special encrypted
protocol. (LED’s, Beeper, Keys and Display are
controlled over the RS485 communication)
RF interface AEpacks
- Third party systems
- AEOS Wiegand
Wiegand output connected to Third party systems (or
to AEOS Wiegand interfaces). LED’s andBeeper are
controlled by hard wiring. (PINcode possible)
RF interface XS systems
Accessor III /
SimpleXS
AB350
AX1014
AX1014
AX1014
AX1014 AX1014
Invexs uses existing antenna cabling
(Coax + 3*0,25qmm for LED’s).
On each AEpack-RF interface an AX1014
must be added. Connections: see AX1014
Invexs uses existing antenna cabling
(Coax + 3*0,25qmm for LED’s).
On each XS reader-RF interface an AB350
must be added. Connections: see AB350
Remark: Configurations can be determined by using the configuration card.
Attention: Check the ConvexsInvexs_InstallationGuide chapter 8 (Available reader Firmware) for the
compatibility for the used readers.
TAMPER SWITCH
This tamper switch is an optical device, which is triggered by the amount of light. Depending on the
applied configuration the result of activating the tamper switch can differ.
BEEPER INDICATIONS
Beeper is also used for indication of loading the configuration:
High sound beep (‘happy sound’): Configuration is loaded correct, second high sound beep
indicates that this configuration can be used with this Invexs
Low sound beep (‘unhappy sound’): Configuration is not correct loaded or no configuration
available at startup
© Nedap N.V.
Invexs 170 readers Installation sheet
Page 3 of 4
..--. ~
c:=Ii::3 FI®_R
-=In::,v..:.;e;;.:x""s:...1"-7'-'O'-r::..;:e:..::a:;.=d;.::.er=s
FCC ID: CGDINVEXS170
and
IC: 1444A-INVEXS170
Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis
aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interférence, et
(2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération
non pas voulu de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could void the user’s
authority to operate the equipment.
SPECIFICATIONS
M170
Mifare
MD170
Invexs 170 Product numbers see table below: For Screen / dis la contact Neda
Colour
Reader
Ke ad
Screen / Dis la
Black
M170B
9833900
MK170B
9834230
MKS I 70B
9939822
Wbite
MI70W
9832750
MK170W
9832920
MKS 170W
9833390
Black
MD170B
9834400
MDK170B
9834680
MDKSI70B
9939849
MifareDESFrr~e __ _+~W~h~it~e--~MD~I~7~OW~--~9~83~4~3~7~0_+~MD~K~17~0~W~~~9~8~3~45~4~0~~M~D~K~S~I~70~W~~~98~9~1~8~20~
MN170
Black
MNI70B
9834060
MNK170B
9833730
MNKS170B
9833870
NtifareNedap
MND170
~W~h~it~e--~MN~I~7~OW
__ --~9~83~2~8~9~0-+~~~~17~O_VV
__ ~~9~8~3~30~8~0~~M--N-K~S~17-0~W--~~98~3~3~4~20~
Black
MND170B
9899570
MNDK170B
9938761
MNDKS170B
9938796
Ntifare DESFire Ne=-=d=a!:..p_L~VVh~it~e
__ L.:.:MND=::..:1~7..::0.:.:vv'---'-i
..:::9~89::..:9:...:4:.:::3~0_L~MND:::::...:::::;K:=.17:..::0:...:w-'---'-i~9:..::9:.:::3:::.87.:..:5::::3:....J.-'MND=.:=K::::Sc:.l.:...:7
Dimensions:
171 x 75 x25 mm
Power Supply:
IOVDC - 30VDC
Environment:
Tamper switch:
Communication:
Temperature:
Yes
RS485 (Encrypted AEOS protocol to APx003, (firmware APx003rs485NR).
RS485 plain
Wiegand Data 0 and Data I (protocol depending of configuration)
RF Modulator (120 kHz for AXI014 or AB350)
Beeper (Beep ON / OFF, controlled by application)
Open collector to GND, max 20mA
UL * led
Open collector to GND, max 20mA
NA * led
Open collector to GND, max 20mA
UL (green) NA (red) ,MD (blue) (if available)
Antenna 1: 120 kHz, Nedap XS compatible (PM and AM cards).
Detection distance UniXS card: 15 cm
Antenna 2: 13,56 MHz, Mifare compatible
Detection distance Mifare card: 5 em
Mifare EY1 card: I em
Inputs:
Indicators:
Antennas (internal):
Weight: ± 200 gr
Power consumption: 70mA@12VDC, 35mA@24VDC
M.NKS:
140mA@12VDC, 70mA@24VDC
Operating: 0 - 55°C, Storage: -30 - 65 °C Relative humidity: 10 - 93% non condensing
CABLE SPECIFICATIONS
RS485:
2 x 2 x 0,25mm' shielded, max cable length: 1000 meter, cable capacity <= 100pF/meter
ULlGND/NA:
3 x 0,25mrn', max cable length: 50 meter
XS MOD / GND:
Coax RG58U, max cable length: 50 meter
Or 5 x 0,25mm' shielded, max cable length: 50 meter, cable capacity <= 100pF/meter
Wiegand:
4 x 0,25mm' shielded (excl. LED's), max cable length: ISO meter, depending on receiving device.
MORE INFORMATION:
For more detailed information contact your local Nedap supplier or check the internet site.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2012:02:23 11:42:25Z
Creator                         : Microsoft® Office Word 2007
Modify Date                     : 2012:07:09 14:34:26+02:00
Has XFA                         : No
Language                        : en-US
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : Microsoft® Office Word 2007
Metadata Date                   : 2012:07:09 14:34:26+02:00
Producer                        : Microsoft® Office Word 2007
Format                          : application/pdf
Document ID                     : uuid:55d2466e-9573-423f-bf67-cc53cdac3eab
Instance ID                     : uuid:06eb75de-4815-44ce-9753-b8d8a0232263
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGDINVEXS170

Navigation menu