SENSIT SYSTEM
install guide
04-03-2015 | v1.5.2 RC
SENSIT SYSTEM | MANUAL
Introduction
CONTENT
INTRODUCTION _________________________________________________________ 6
SENSIT SYSTEM _________________________________________________________ 7
2.1
ARCHITECTURE ___________________________________________________ 7
2.2
THE SENSIT SENSORS ______________________________________________ 8
2.2.1 SENSIT IR __________________________________________________ 8
2.2.2 SENSIT FLUSH MOUNT _______________________________________ 9
2.2.3 SENSIT SURFACE MOUNT ___________________________________ 10
2.3
RELAY NODES ___________________________________________________ 11
2.3.1 SENSIT RELAY NODE 2G _____________________________________ 11
2.4
DATA COLLECTORS _______________________________________________ 12
2.4.1 STANDARD DATA COLLECTOR _______________________________ 12
2.4.2 DATA COLLECTOR GPRS ____________________________________ 13
2.5
ADDITIONAL EQUIPMENT _________________________________________ 14
2.5.1 ELECTRONIC PARKING LICENSE ______________________________ 14
2.5.2 SENSIT DISPLAY ___________________________________________ 15
2.6
SENSIT INTERFACE SOFTWARE _____________________________________ 16
INSTALLATION PROCEDURE ______________________________________________ 17
3.1
HOW TO INSTALL THE SENSIT SYSTEM IN 4 STEPS ____________________ 17
STEP 1 – PREPARATION _____________________________________ 17
STEP 2 – DATA COLLECTORS AND RELAY NODE INSTALLATION __ 17
STEP 3 – SENSIT INSTALLATION ______________________________ 17
STEP 4 – SETTING UP THE SENSIT INTERFACE SOFTWARE ________ 17
RELAYNODETOOL ______________________________________________________ 18
4.1
SCALED DRAWING ________________________________________________ 18
4.2
START A NEW PROJECT ___________________________________________ 19
4.3
THE FIRST SEGMENT ______________________________________________ 19
4.3.1 IMPORT MAP ______________________________________________ 20
4.3.2 SET THE SCALE ____________________________________________ 20
4.3.3 PLACE THE DATA COLLECTOR _______________________________ 21
4.3.4 PLACE THE RELAY NODE ____________________________________ 21
4.4
THE SECOND SEGMENT ___________________________________________ 22
4.4.1 IMPORT MAP ______________________________________________ 22
4.4.2 SET THE SCALE ____________________________________________ 23
4.4.3 PLACE THE DATA COLLECTOR _______________________________ 23
4.4.4 PLACE THE RELAY NODE ____________________________________ 24
4.5
SAVE THE PROJECT _______________________________________________ 25
4.6
EXPORT PROJECT FILES ___________________________________________ 25
4.6.1 PROJECT FILE ______________________________________________ 25
4.6.2 SAVE AS IMAGE ____________________________________________ 25
4.6.3 PRINT PROJECT ____________________________________________ 25
4.7
REQUEST PROJECT REVIEW ________________________________________ 25
INSTALLATION DATA COLLECTOR ________________________________________ 26
5.1
SAFETY PRECAUTIONS ____________________________________________ 26
5.2
FCC AND IC DECLARATIONS ________________________________________ 26
Compliance statements (part15.19) ___________________________________ 26
5.3
DATA COLLECTOR INSTALLATION __________________________________ 27
5.3.1 MOUNTING _______________________________________________ 27
5.3.2 POWER SUPPLY ____________________________________________ 28
5.3.3 TCP/IP COMMUNICATION ___________________________________ 28
5.3.4 ANTENNA _________________________________________________ 28
5.3.5 LED INDICATIONS __________________________________________ 28
5.4
DATA COLLECTOR GPRS INSTALLATION _____________________________ 29
5.4.1 MOUNTING _______________________________________________ 29
5.4.2 BACKUP BATTERY __________________________________________ 30
5.4.3 POWER SUPPLY ____________________________________________ 30
5.4.4 SIM CARD _________________________________________________ 31
2/92
SENSIT SYSTEM | MANUAL
Introduction
5.4.5
ANTENNA _________________________________________________ 31
DATA COLLECTOR CONFIGURATION ______________________________________ 32
6.1
TCP/IP CONFIGURATION ___________________________________________ 32
6.2
GPRS CONFIGURATION ____________________________________________ 33
6.3
GPRS MODEM LED BEHAVIOR ______________________________________ 33
6.3.1 RED LED __________________________________________________ 34
6.3.2 AMBER LED _______________________________________________ 34
6.4
VERIFY COMMUNICATION _________________________________________ 34
MOUNTING THE RELAY NODE 2G _________________________________________ 35
7.1
SAFETY PRECAUTIONS ____________________________________________ 35
7.2
FCC AND IC DECLARATIONS ________________________________________ 35
Compliance statements (part15.19) ___________________________________ 35
RF Exposure (OET Bulletin 65) _______________________________________ 35
7.3
DIMENSIONS ____________________________________________________ 36
7.4
INSTALLATION CONDITIONS _______________________________________ 36
7.5
REQUIRED INSTALLATION MATERIALS ______________________________ 36
7.6
INSTALLATION PROCEDURE _______________________________________ 37
7.7
BATTERY REPLACEMENT __________________________________________ 38
MOUNTING THE SENSIT IR _______________________________________________ 39
8.1
SAFETY PRECAUTIONS ____________________________________________ 39
8.2
FCC AND IC DECLARATIONS ________________________________________ 39
Compliance statements (part15.19) ___________________________________ 39
8.3
DIMENSIONS ____________________________________________________ 40
8.4
INSTALLATION CONDITIONS _______________________________________ 40
8.5
REQUIRED INSTALLATION MATERIALS ______________________________ 40
8.6
INSTALLATION PROCEDURE _______________________________________ 41
8.7
REPLACEMENT ___________________________________________________ 41
MOUNTING THE SENSIT FLUSH MOUNT ____________________________________ 42
9.1
SAFETY PRECAUTIONS ____________________________________________ 42
9.2
FCC AND IC DECLARATIONS ________________________________________ 42
Compliance statements (part15.19) ___________________________________ 42
9.3
DIMENSIONS ____________________________________________________ 43
9.4
INSTALLATION CONDITIONS _______________________________________ 43
9.5
INSTALLATION MATERIAL _________________________________________ 43
9.6
INSTALLATION PROCESS __________________________________________ 44
9.7
REPLACEMENT ___________________________________________________ 44
10 MOUNTING THE SENSIT SURFACE MOUNT _________________________________ 45
10.1 SAFETY PRECAUTIONS ____________________________________________ 45
10.2 FCC AND IC DECLARATIONS ________________________________________ 45
Compliance statements (part15.19) ___________________________________ 45
10.3 DIMENSIONS ____________________________________________________ 46
10.4 REQUIRED INSTALLATION MATERIALS ______________________________ 46
10.5 INSTALLATION PROCESS __________________________________________ 47
10.6 REPLACEMENT ___________________________________________________ 48
11 MOUNTING THE SENSIT EPL ______________________________________________ 49
11.1
SAFETY PRECAUTIONS ____________________________________________ 49
11.2 FCC AND IC DECLARATIONS ________________________________________ 49
Compliance statements (part15.19) ___________________________________ 49
11.3
DIMENSIONS ____________________________________________________ 50
11.4 REQUIRED INSTALLATION MATERIALS ______________________________ 50
11.5
INSTALLATION PROCESS __________________________________________ 50
12 PROJECT SUPPORT______________________________________________________ 51
12.1 SITE SURVEY & INSTALLATION ADVICE ______________________________ 51
12.2 ON-SITE CERTIFICATION ___________________________________________ 51
3/92
SENSIT SYSTEM | MANUAL
Introduction
13 SENSIT INTERFACE SOFTWARE ___________________________________________ 52
13.1
INTRODUCTION __________________________________________________ 52
13.2 USERS __________________________________________________________ 52
13.2.1 LOGIN ____________________________________________________ 52
13.2.2 LOGOUT __________________________________________________ 53
13.3
DASHBOARD_____________________________________________________ 53
13.4 PARKING ENFORCEMENT __________________________________________ 54
13.4.1 PERMIT ADMINISTRATION ___________________________________ 55
13.4.2 PERMIT ZONE CONFIGURATION ______________________________ 56
13.5
DETECTION ______________________________________________________ 57
13.5.1 DATA COLLECTOR _________________________________________ 57
13.5.2 NODE CROSS CHECK _______________________________________ 57
13.5.3 NODE PRESENCE ___________________________________________ 58
13.6 DEFINITION ______________________________________________________ 58
13.6.1 RELAY NODE CONFIGURATION ______________________________ 58
13.6.2 PARKING BAY CONFIGURATION ______________________________ 59
13.6.3 PARKING LOT CONFIGURATION ______________________________ 60
13.6.4 MONITOR CONFIGURATION _________________________________ 60
Site Name _______________________________________________________ 60
Monitor Color Mapping _____________________________________________ 60
Map List _________________________________________________________ 60
13.6.5 OVERSTAY CONFIGURATION ________________________________ 61
13.6.6 SENSOR CALIBRATION ______________________________________ 62
13.6.7 DISPLAY __________________________________________________ 62
Display Configuration ______________________________________________ 62
Display Current View _______________________________________________ 63
Display View Settings ______________________________________________ 63
13.7
MONITOR _______________________________________________________ 64
13.8 OCCUPANCY REPORT _____________________________________________ 64
13.8.1 OCCUPANCY LIST __________________________________________ 64
13.8.2 OCCUPANCY CHART ________________________________________ 65
13.8.3 OVERSTAY REPORT ________________________________________ 65
13.8.4 PARKING VIOLATION PROBABILITY ___________________________ 65
13.8.5 MAP MONITOR ____________________________________________ 66
13.9 DIAGNOSE_______________________________________________________ 66
13.9.1 ICE DETECT MODE _________________________________________ 66
13.9.2 BATTERY LOW WARNINGS __________________________________ 66
13.9.3 BATTERY PLOT ____________________________________________ 67
13.9.4 SENSOR ANALYSIS _________________________________________ 67
13.9.5 SENSOR CALIBRATION ERRORS ______________________________ 67
13.9.6 DATA COLLECTOR CONNECTION LOG ________________________ 68
13.9.7 BAD NETWORK EVENTS _____________________________________ 68
13.9.8 PENDING TX MESSAGES ____________________________________ 68
13.9.9 PENDING RX MESSAGES ____________________________________ 68
13.10 SETTINGS _______________________________________________________ 68
13.10.1 USER SETTINGS ____________________________________________ 68
Change Password _________________________________________________ 68
13.10.2 SYSTEM SETTINGS _________________________________________ 69
System Information _______________________________________________ 69
System Reboot ___________________________________________________ 69
Time Configuration ________________________________________________ 69
Node Gateway List ________________________________________________ 69
Local Configuration ________________________________________________ 70
Active Http Sessions _______________________________________________ 71
Status Reading Interval Settings _____________________________________ 71
13.10.3 EXPERT SETTINGS __________________________________________ 71
Console _________________________________________________________ 71
EPL settings ______________________________________________________ 72
EPL old licenses (deprecated) ________________________________________ 72
14 ADVANCE CONFIGURATION ______________________________________________ 73
14.1 INKSCAPE _______________________________________________________ 73
4/92
SENSIT SYSTEM | MANUAL
Introduction
15 FREQUENTLY ASKED QUESTIONS _________________________________________ 75
15.1
GENERAL ________________________________________________________ 75
15.2 MAGNETIC SENSOR _______________________________________________ 76
15.2.1 CALIBRATION______________________________________________ 76
15.3
OPTICAL SENSOR_________________________________________________ 77
15.3.1 CALIBRATION______________________________________________ 78
15.4 MORE INFORMATION SENSIT AND MOUNTING _______________________ 78
15.5 INSTALLATION ___________________________________________________ 79
15.6 BATTERY LIFE ____________________________________________________ 79
15.7
RELAY NODES ___________________________________________________ 80
15.8 DATA COLLECTOR ________________________________________________ 81
15.9 SENSIT INTERFACE SOFTWARE (SIS) ________________________________ 83
15.10 NETWORK & COMMUNICATION ____________________________________ 85
15.11 TECHNICAL MATTERS _____________________________________________ 86
16 APPENDIX _____________________________________________________________ 87
A RAPID MORTAR _________________________________________________________ 87
B MODIFIED SILICON POLYMER _____________________________________________ 88
B.1
Description_______________________________________________________ 88
B.2
Field of application ________________________________________________ 88
B.3
Advantages ______________________________________________________ 88
B.4
Method of use ____________________________________________________ 88
B.5
TECHNICAL DATA ________________________________________________ 88
C POLYURETHAN _________________________________________________________ 90
D DISCLAIMER ____________________________________________________________ 91
DOCUMENT REVISION ___________________________________________________ 92
5/92
SENSIT SYSTEM | MANUAL
Introduction
INTRODUCTION
The SENSIT vehicle detection system facilitates accurate measurement on occupancy of
individual parking spaces in car parks, and on-street parking spaces. This information can be
used to guide traffic to free parking spaces but can also be used for on-street parking
enforcement and overstay detection. For on-street enforcement the number of occupied
parking spaces can be compared with the number of payments realized by the pay station.
For overstay detection the system alerts instantly a parking officer to the presence of
nearby overstaying vehicles. Based on this information you can exactly determine which
space to enforce.
All the SENSIT vehicle detection sensors are featured with detection and communicate
wireless, creating their own network. The SENSIT sensors do not require power wiring, in
contrast to conventional systems that require wiring throughout the car park and mounting
onto the ceiling.
Easy installation of the sensors is guaranteed. Once installed no maintenance is required for
years. The actual status (occupancy) of the sensor is transmitted to the Relay Node, which is
part of the wireless mesh network.
Different types of ruggedly designed sensors are available to accommodate installation in
indoor car parks, on-street spaces and road surfaces.
6/92
SENSIT SYSTEM | MANUAL
SENSIT System
SENSIT SYSTEM
2.1
ARCHITECTURE
The actual status (occupancy) of the SENSIT sensors is finally collected by one or more Data
Collector. The SENSIT sensors transmit their status via one or more Relay Nodes to the
Data Collector. The Data Collector is the interface between the wireless sensors network
and the SENSIT Interface Software running on the server. The Data Collector transmits
status information about the sensors to the server using TCP/IP via Ethernet or GPRS
communication.
Figure 1: System Architecture
For a parking site you need at least one Data Collector, a Relay Node and a SENSIT per
parking bay.
7/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.2
THE SENSIT SENSORS
Three types of ruggedly designed sensors are available to accommodate installation in
indoor car parks, on-street spaces and road surfaces. The standard, most used, SENSIT
Sensor is the SENSIT IR. For regions with lots of snow the SENSIT Flush Mount is designed
to withstand frequent snow ploughing. The SENSIT Surface Mount is designed for indoor
car parks or roof tops where drilling is not allowed.
2.2.1
SENSIT IR
Vehicle detection sensor featured with dual detection technology
(infrared and earth-magnetic field detection. The SENSIT IR is
mounted into the floor of each parking space allowing for vandal
resistant installation, making the unit suitable for on-street
application.
SENSIT IR
Operating
frequency
SENSIT IR EU: 868.2 MHz
SENSIT IR CN: 868.2 MHz
SENSIT IR US: 902-928 MHz (FHSS)
SENSIT IR AU: 915-927 MHz (FHSS)
Detection
Magnetic and IR
Load resistance
Heavy traffic
Mounting
Into the floor
Weight
365 gram
(12.87 oz)
Dimensions
Ø 78 mm
Into floor 55 mm
(3.07 inch)
(2.16 inch)
Color
Black or Yellow (optional)
Detection height
0…90 cm
Protection
IP67, completely sealed housing PE
Operating
temperature
-40 ... +85°C
Power supply
Built in Lithium batteries expected lifetime of 5-10 years *
Antenna
Included
Accuracy: 98%
(0 … 35.5 inch)
(-40°F … +185°F)
* Under normal circumstances and dependent on settings.
8/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.2.2
SENSIT FLUSH MOUNT
Vehicle detection sensor for flush mount installation in the road
surface. The sensor is resistant to snow ploughs and offers vandal
resistant installation. The SENSIT Flush Mount is featured with
earth-magnetic field detection.
SENSIT Flush Mount
Operating
frequency
SENSIT FLUSH MOUNT EU: 868.2 MHz
SENSIT FLUSH MOUNT CN: 868.2 MHz
SENSIT FLUSH MOUNT US: 902-928 MHz (FHSS)
SENSIT FLUSH MOUNT AU: 915-927 MHz (FHSS)
Detection
Magnetic
Load resistance
Heavy traffic
Mounting
Into the floor
Weight
350 gram
(12.35 oz)
Dimensions
Ø 78 mm
Into floor 72 mm
(3.07 inch)
(2.09 inch)
Color
Black
Detection height
0…90 cm
Protection
IP67, completely sealed housing PE
Operating
temperature
-40 ... +85°C
Power supply
Built in Lithium batteries expected lifetime of 5-10 years*
Antenna
Included
Accuracy: 95%
(0 … 35.5 inch)
(-40°F … +185°F)
* Under normal circumstances and dependent on settings.
9/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.2.3
SENSIT SURFACE MOUNT
Vehicle detection sensor designed for car parks where
drilling is not allowed or non-permanent mounting is
required. The unit is suitable for indoor car parks and
rooftop parking’s. The sensor can easily be glued onto
the surface. Replacement can be achieved by removing
the sensor installed in the mounting ring. The SENSIT
Surface Mount is featured with dual detection technology (infrared and earth-magnetic
field).
SENSIT Surface Mount
Operating
frequency
SENSIT SURFACE MOUNT EU: 868.2 MHz
SENSIT SURFACE MOUNT CN: 868.2 MHz
SENSIT SURFACE MOUNT US: 902-928 MHz (FHSS)
SENSIT SURFACE MOUNT AU: 915-927 MHz (FHSS)
Detection
Magnetic and IR
Load resistance
Regular traffic
Mounting
On the floor surface
Weight
455 gram
Dimensions
Mounting ring:
Sensor:
Height:
Color
Sensor black and yellow (optional black) ring
Detection height
0…90 cm
Protection
IP67, completely sealed housing PE
Operating
temperature
-40 ... +85°C
Power supply
Built in Lithium batteries expected lifetime of 5-9 years *
Antenna
Included
Accuracy: 98%
(16.05 oz)
Ø 240
Ø 167 cm
35mm
(9.45 inch)
(6.57 inch)
(1.38 inch)
(0 … 35.5 inch)
(-40°F … +185°F)
* Under normal circumstances and dependent on settings.
10/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.3
RELAY NODES
A Relay Node allows for communication increase and ensures a robust and reliable
communication network. It ensures fast transmission of event messages from the vehicle
detection sensors to the Data Collector.
2.3.1
SENSIT RELAY NODE 2G
The Relay Node 2G is has an improved communication range and
a battery lifetime. It ensures a robust and reliable communication
network. The Relay Node 2G ensures fast transmission of event
messages from the SENSIT sensors to the Data Collector. Relay
Node 2G should be mounted preferable at about 3 – 6 meters
[10- 20 ft] from the floor (e.g. onto a lamppost) to allow for
visible view of the sensors.
Relay Node 2G
Operating
frequency
SENSIT RELAY NODE 2G EU: 868.2 MHz
SENSIT RELAY NODE 2G CN: 868.2 MHz
SENSIT RELAY NODE 2G US: 902-928 MHz (FHSS)
SENSIT RELAY NODE 2G AU: 915-927 MHz (FHSS)
Weight
540 gram
(12.87 oz)
Dimensions
200 x 170 x 204 mm
inch)
(7.87 x 6.69 x 8.03
Mounting
Onto a pole, lamppost or wall, mounting bracket included.
Mounting height
3 – 6 meters
(10 – 20 ft.)
Pole dimensions
Min. Ø 40 mm
Max. Ø 150 mm
(1.57 inch)
(6 inch)
Protection
IP65
Operating
temperature
-40 ... +85°C
(-40°F … +185°F)
Communication
range *
DC – RN 2G omnidirectional
DC – RN 2G directional max.
DC GPRS – RN 2G max.
RN 2G – RN 2G max.
SENSIT – RN 2G omnidirectional
SENSIT – RN 2G directional
35 m
50 m
10 m
100m
35 m
50 m
Power supply **
Replaceable Lithium batteries expected lifetime of 5 years
Antenna
connection
Antenna included
(135 ft)
(164 ft)
(33 ft)
(328 ft)
(135 ft)
(164 ft)
* Dependent on the environment.
** Under normal circumstances and dependent on settings.
11/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.4
DATA COLLECTORS
The actual status (occupancy) of the SENSIT sensors is collected by one or more Data
Collector. The Data Collector is the interface between the wireless sensors network and the
SENSIT Interface Software running at the server. The Data Collector transmits status
information about the sensors to the server using TCP/IP Ethernet communication.
For a parking site you need at least one Data Collector, a Relay Node and a SENSIT per
parking bay. One Data Collector is required per 250 parking bays. All Data Collectors must
be separated as far as possible from each other, preferably at the remote corners of the site.
The Data Collector is available in 2 different versions: the standard Data Collector and the
Data Collector GPRS.
2.4.1
STANDARD DATA COLLECTOR
The Data Collector can be mounted in a central enclosure,
however please ensure that the enclosure is not made of metal.
The Data Collector is featured with RF communication with the
SENSIT. The material used for the enclosure should be
transparent for RF signals.
Data Collector
Operating
frequency
SENSIT DATACOLLECTOR EU: 868.2 MHz
SENSIT DATACOLLECTOR CN: 868.2 MHz
SENSIT DATACOLLECTOR US: 902-928 MHz (FHSS)
SENSIT DATACOLLECTOR AU: 915-927 MHz (FHSS)
Dimensions
125 x110 x 65 mm
(4.9 x 4.3 x 2.6 inch)
Weight
105 gram
(3.7 oz)
Protection
IP44
Operating
temperature
-0°C … +55°C
Humidity
10%...90% relative humidity, non-condensing
Communication
range*
From SENSIT to Data Collector in principle unendless as the
nodes communicate to each other. It is recommended to
locate the nearest Relay Node within 25 meters (82 ft) of the
Data Collector.
Communication
RJ45 TCP/IP (or RS232 DIN-9 F)
Power input
5 VDC power adapter included 110-240 VAC.
Antenna
connection
Antenna included
(32°F … +85°F)
* Dependent on the environment.
12/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.4.2
DATA COLLECTOR GPRS
The Data Collector GPRS can be installed virtually anywhere
due to its IP65 weatherproof housing and embedded GPRS
wireless modem. The only requirements are an AC mains
power supply and that it should be installed within reach of the
SENSIT wireless network.
Data Collector IP65 GPRS
Operating
frequency
SENSIT DATACOLLECTOR GPRS EU: 868.2 MHz
SENSIT DATACOLLECTOR GPRS CN: 868.2 MHz
SENSIT DATACOLLECTOR GPRS US: 902-928 MHz (FHSS)
SENSIT DATACOLLECTOR GPRS AU: 915-927 MHz (FHSS)
Dimensions
252 x 251 x 89 mm
(10 x 10 x 3.5 inch)
Weight
2200 gram
(77 oz)
Protection
IP65
Operating
temperature
-40°C … +65°C
Communication
range*
From SENSIT to Data Collector in principle unendless as the
nodes communicate to each other. It is recommended to
locate the nearest Relay Node within 10 meters (33 ft) of the
Data Collector GPRS.
Communication
GPRS mobile
Power input
110-240 VAC 50/60Hz
Antenna
connection
Antenna included
(-40°F … +149°F)
* Dependent on the environment.
13/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.5
ADDITIONAL EQUIPMENT
Additional equipment is available to expand the functionality of the SENSIT system.
2.5.1
ELECTRONIC PARKING LICENSE
The Electronic Parking License (EPL) physically is a device
that is positioned inside the car. Whenever the car stops
for a specific period of time it considers the car to be
parked and it will look for a wireless SENSIT network. If a
network is detected, it will make itself know to the
network. Its unique EPL identifier is registered at the
server with SENSIT Interface Software (SIS). The SIS is triggered when parking bays that
require a license change status (become occupied or free). When such a parking bay is
occupied the system will calculate the odds of the parking bay being occupied by an
unauthorized vehicle.
Electronic Parking License
Operating
frequency
SENSIT EPL EU: 868.2 MHz
SENSIT EPL US: 902-928 MHz (FHSS)
SENSIT EPL AU: 915-927 MHz (FHSS)
Mounting
Attaches with suction pads to the windscreen on the inside
of the car
Weight
120 gram
(4.2 oz)
Dimensions
116 x 72 x 27 mm
(4.6 x 2.8 x 1.1 inch)
Color
Grey, RAL7016
Protection
IP32
Operating
temperature
-40 ... +85°C
Power supply
User replaceable AAA 1.5V alkaline batteries
Antenna
Included
(-40°F … +185°F)
14/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.5.2
SENSIT DISPLAY
The SENSIT Display is an in-network LED display that is part of
the Wireless SENSIT Network (WSN). The LED display enables
signage of free parking spaces for stand-alone parking
guidance installations. The display is designed for outdoor use,
indicating the number of available parking spaces per parking
lot thus guiding motorists to the closest parking space.
Electronic Parking License
Operating
frequency
SENSIT DISPLAY EU: 868.2 MHz
SENSIT DISPLAY US: 902-928 MHz (FHSS)
SENSIT DISPLAY AU: 915-927 MHz (FHSS)
Display
Graphical display for outdoor use, single sided
Digit height
max. 3 digits
Dimensions
310 x 150 x 60 mm
(12.2 x 5.9 x 2.4 inch)
Weight
1500 gram
(52.9 oz)
Protection
IP55
Color
Black housing, Yellow LEDs
Readability
> 60 m
Viewing angle
120º
Operating
temperature
0 ... +50°C
Number of displays
Max. 2 displays can be used in the WSN, more displays will
introduce to much latency for the whole system.
Power supply
230 VAC
Antenna
Included
90 x 130 mm
(3.5 x 5.1 in)
(196 ft)
(32°F … +122°F)
15/92
SENSIT SYSTEM | MANUAL
SENSIT System
2.6
SENSIT INTERFACE SOFTWARE
SENSIT Interface Software allowing easy system integration into enforcement, traffic
guidance or parking guidance management application. The main features of the SENSIT
Interface Software to help you and make easy system integration possible are:

Installation

Configuration

Basic administration

Integration
The SENSIT Interface Software enables easy installation of the wireless sensor network.
Once the network and sensors are installed, the sensors will automatically appear in the
software. Configuration of sensors to specific parking bays, parking zone and parking lot
can easily be realized.
Additionally the software configures and monitors communication of the SENSIT node
network. It monitors the data transfer between the sensors and the Data Collectors.
Moreover it also analyzes communication reliability of the sensor network in a graphical
map, automatically alerting areas for maintenance.
Easy integration can be done via to SOAP or REST interface.
SOAP or Simple Object Access Protocol, is a protocol specification for exchanging
structured information. It relies on Extensible Mark-up Language (XML) for its message
format.
The SOAP interface can query data from the SIS using the http(s) interface, the found data
is returned in a XML description format.
Representational state transfer (REST) is a simple stateless architecture that generally runs
over HTTP(S). REST involves reading a designated Web page that contains an XML file. The
XML file describes and includes the desired content.
16/92
SENSIT SYSTEM | MANUAL
Installation Procedure
INSTALLATION PROCEDURE
3.1
HOW TO INSTALL THE SENSIT SYSTEM IN 4 STEPS
The installation of a SENSIT system can be described in 4-steps: The preparation, the
installation of Data Collectors and Relay Nodes, the installation of SENSIT sensors and
finally setting up the SENSIT Interface Software.
STEP 1 – PREPARATION
a. Arrange a scaled map of the site.
b. Make a site inspection to gather information:

Draw on the map where the parking bays are located.

Draw on the map where you can mount Relay Nodes

Draw on the map the possible locations for the Data Collector.
c. Make an installation plan:

Number every parking bays with a unique number.

Plan the final Relay Node and Data Collector locations to form a
covering network.
Note
There is also a planning-tool
(RelayNodeTool) available to
plan the Relay Node and Data
Collector locations. See
chapter below for an example.
STEP 2 – DATA COLLECTORS AND RELAY NODE INSTALLATION
a. Install and power-up the Data Collector according the plan.
b. Activate and install the Relay Nodes according the plan.
c. Write the ID numbers of the Data Collectors and Relay Nodes at the right location
in the plan.
d. Verify at the server that all Data Collectors and Relay Nodes are online.
STEP 3 – SENSIT INSTALLATION
a. Free the bays and close off the parking area.
b. Mark the right location at the road surface with a piece of chalk or paint.
c. Distribute the SENSIT sensors at the, to be installed locations and activate them
with the magnet.
d. Make a list of the correct ID numbers and bay numbers.
e. Verify at the server if all SENSIT sensors come online.
f. Drill the holes and glue the SENSIT sensors.
g. Calibrate the SENSIT sensors without cars or metal tools in the neighborhood of
the SENSIT’s.
Note
Ask your Nedap account
manager for special
installation tools to configure,
calibrate and register the ID to
bay bindings.
STEP 4 – SETTING UP THE SENSIT INTERFACE SOFTWARE
a.
Make a (simple) Inkscape drawing of the site based on the map and gathered
information during STEP 1 and STEP 2.

Draw the Relay Nodes and Data Collectors at the right locations

Draw the bays at the right locations
b. Upload the SVG-drawing to the server.
c. Make a correct CSV-file and upload it to the server.
d. Verify if all Data Collectors, Relay Nodes and SENSIT sensors show up correctly in
the system.
Note
Inkscape is an open-source
drawing program to create
the SVG (Scalable Vector
Graphic) drawing.
17/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
RELAYNODETOOL
The RelayNodeTool software is developed to get a good estimation of the needed system
components; Data Collectors and Relay Nodes. The estimation of needed components is
based on drawings of the site. In this way you are able to get a good idea of the needed
components.
In this example we are going to design the SENSIT system for two segments; the parking
basement and the outside parking terrain at the Nedap Headquarter office.
4.1
Note
Please keep in mind that with
help of this RelayNodeTool
you can determine the
needed components, but it
will always be an estimation.
SCALED DRAWING
First get a drawing of the parking lot(s) and find out if it are open areas or closed (indoor)
areas. Try to get information about mounting locations, like lampposts and poles for Relay
Nodes and power and internet for the Data Collector. Below you can find a map of the
Nedap Headquarter office, with its parking areas.
Figure 2: Example drawing of parking lots.
The drawing of a segment can be copied out of the larger map e.g. via the standard
Snipping Tool of Windows.
Figure 3: The Basement and the outside area.
18/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
4.2
START A NEW PROJECT
Fill-in the project details; the project title, your name and you company name. Please also
indicate the country and region where the project is situated.
Figure 4: RelayNodeTool: Project details
4.3
THE FIRST SEGMENT
Via the option Segment -> Add new segment, or click on the tab  you can add a
segment to the design. Fill-in the segment properties; the segment name and the number
of parking bays.
Note
The Relay Node Tool will give
you a warning if you have
more than 500 bays in a
segment. With more than 500
bays, segmentation is
necessary. Please contact
your Nedap account manager
for more information.
Figure 5: RelayNodeTool: Segment properties
19/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
4.3.1
IMPORT MAP
First import the drawing via the Paste from clipboard option or open the map image file.
Figure 6: RelayNodeTool: Map import.
4.3.2
SET THE SCALE
Now set the scale, for an open area you set it at 25m if there isn’t a clear indication about
the size you can use the width of 10 parking bays:
Figure 7: RelayNodeTool: Scaling of the map.
20/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
4.3.3
PLACE THE DATA COLLECTOR
Place at least one Data Collector for every 250 bays. Use the information you already
gathered or ask the client for the installation options for the Data Collector(s). At least you
need a power connection and for a standard Data Collector you also need an internet
connection.
Figure 8: RelayNodeTool: DataCollector placement.
4.3.4
PLACE THE RELAY NODE
Place the Relay Nodes at locations were you can mount it e.g. at lampposts in a way that it
covers all parking bays. With the tool you can choose between Relay Nodes 2G (omni- or
directional) or Relay Nodes 1G.
Note
The Relay Node Tool will give
you a warning if you have
more than 16 Relay Nodes in a
segment. With more than 16
Relay Nodes, segmentation
might be necessary. Please
contact your Nedap account
manager for more
information.
Figure 9: RelayNodeTool: RelayNode placement.
21/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
4.4
THE SECOND SEGMENT
Via the option Segment -> Add new segment, or click on the tab  you can add a
segment to the design. Fill-in the segment properties; the segment name and the number
of parking bays.
Figure 10: RelayNodeTool: Segment properties
4.4.1
IMPORT MAP
Also import the drawing for the second segment via the Paste from clipboard option or
open the map image file.
Figure 11: RelayNodeTool: Map import for the second segment.
22/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
4.4.2
SET THE SCALE
Also Set the scale, this location is a parking basement with a roof, large concrete columns
and walls. This will influence the range of the Relay Nodes and therefore we advise to
reduce the range with about 20%, so set the range to about 20m e.g. the width of 8 parking
bays.
Figure 12: RelayNodeTool: Scaling of the map.
4.4.3
PLACE THE DATA COLLECTOR
Because this basement parking area is half open we can use the Data Collector of the open
area, so we don’t need to add one for this segment.
23/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
4.4.4 PLACE THE RELAY NODE
Place the Relay Nodes at locations were you can mount it e.g. at lampposts in a way that it
covers all parking bays. With the tool you can choose between Relay Nodes 2G (omni- or
directional) or Relay Nodes 1G.
There are 2 large concrete walls and after every 3 parking bays there is large concrete pillar,
all is indicated with red. This will influence the range and radiation pattern of the Relay
Nodes.
Figure 13: Imported map with concrete wall and pillar indication.
Probably with only 3 Relay Nodes 2G it is possible to get coverage of all bays, but because of
these large influencing concrete objects we used 2 Relay Nodes 2G extra to make sure all
SENSIT sensors are sufficient reachable.
Figure 14: RelayNodeTool: RelayNode placement
24/92
SENSIT SYSTEM | MANUAL
RelayNodeTool
4.5
SAVE THE PROJECT
Now you can save the project file:
Figure 15: RelayNodeTool: Project save.
4.6
EXPORT PROJECT FILES
4.6.1
PROJECT FILE
You can send the project file (*.rnproj) to a colleague or Nedap so it can be reviewed.
4.6.2
SAVE AS IMAGE
You can save the segments you have designed to an image file, via the option File -> Save
image (current segment and use it in your offer.
4.6.3
PRINT PROJECT
You can print the project file to a normal printer or to a PDF printer like the free PDF writer
CutePDF (http://www.cutepdf.com/) and use this in your offer.
4.7
REQUEST PROJECT REVIEW
You can also request Nedap to review the project you have designed. Fill-in: your name,
company, email address and phone number and write your comments on the design. With
this information and the automatically added *.rnproj file Nedap can give you advise on the
design.
Figure 16: RelayNodeTool: Project review request
25/92
SENSIT SYSTEM | MANUAL
Installation Data Collector
5 INSTALLATION DATA COLLECTOR
The Data Collector is available in two different versions. The installation of the standard
Data Collector is described in chapter 5.3. The installation of a Data Collector GPRS, which
has an IP65 weatherproof housing and features a GPRS modem, is described in chapter 5.4.
5.1
SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and repair.

The Data Collector may only be installed and serviced by qualified service
personnel.

Disconnect the power supply before removing or installing any parts.

To be sure of safety, do not modify or add anything to the Data Collector other
than mentioned in this manual or indicated by NEDAP N.V.
5.2
FCC AND IC DECLARATIONS
FCC ID: CGDSENSDATA and IC: 1444A-SENSDATA
Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada.
L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune
interférence, et (2) cet appareil doit accepter n'importe quelle interférence, y inclus
interférence qui peut causer une opération non pas voulu de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could
void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20cm
separation distance between the antenna and all persons.
Information to the User (Part 15.106(b))
Note: This equipment generates, uses and can radiate radio frequent energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
26/92
SENSIT SYSTEM | MANUAL
Installation Data Collector
5.3
DATA COLLECTOR INSTALLATION
5.3.1
MOUNTING
The Data Collector can be mounted in a central enclosure, however please ensure that the
enclosure is not made of metal. The Data Collector is featured with RF communication with
the SENSIT. The material used for the enclosure should be transparent for RF signals.
Locate an appropriate position for the Data Collector, preferable on a location where power
and communication is available (normally around the gate). Use the four keyholes to mount
the Data Collector in the enclosure.
Figure 17: Data Collector dimensions (mm)
Figure 18: Data Collector connections
27/92
SENSIT SYSTEM | MANUAL
Installation Data Collector
5.3.2
POWER SUPPLY
The Data Collector requires 5 VDC power, this power supply is included. The included
adapter requiring AC power supply in the range from 100 – 240VAC. Maximum current
consumption is 0.35A @ 240VAC. Adapter needs to be:

CSA and UL approved according to NEC Class 2

FCC compliant to Part 15

CE compliant according to EMC and LVD directive (EN 60950-1)
Figure 19: Power supply
5.3.3
TCP/IP COMMUNICATION
The Data Collector has on-board TCP/IP communication. The TCP/IP communication is used
to send the messages from the SENSIT vehicle detections sensors to the SENSIT server
software. See chapter 6.1 for details to configure the TCP/IP settings.
5.3.4
ANTENNA
The Data Collector is featured with an antenna for communication with the SENSIT nodes
within the network. To enable reliable identification ensure to mount the Data Collector in
an enclosure which is transparent for RF signals. The antenna is connected via the SMA 50
jack connector (K6) on the PCB.
5.3.5
LED INDICATIONS
The Data Collector is featured with two LEDs. Table 1 below describes the function of the
LEDs.
Data Collector LED indication.
Green (D1)
LED indicating the presence of the SENSIT network.
A blink indicates that a SENSIT is active in the network.
Red (D2)
Each blink indicates the start of a timeslot (start) in the
network
Table 1: LED indications
28/92
SENSIT SYSTEM | MANUAL
Installation Data Collector
5.4
DATA COLLECTOR GPRS INSTALLATION
5.4.1
MOUNTING
The Data Collector GPRS can be installed virtually anywhere due to its IP65 weatherproof
housing and embedded GPRS wireless modem. The only requirements are an AC mains
power supply and that it should be installed within reach of the SENSIT wireless network.
Figure 20: Data Collector IP65 GPRS dimensions (mm)
29/92
SENSIT SYSTEM | MANUAL
Installation Data Collector
5.4.2
BACKUP BATTERY
Inside the Data Collector GPRS there is a backup battery. This battery is not connected
when the Data Collector leaves the factory. During transport it should be disconnected.
The backup battery is used to keep alive the SENSIT wireless network in case the Data
Collector is powered off temporarily.
When the SENSIT sensors cannot reach the Data Collector for a while, they will
automatically go into a power saving sleep mode. In this sleep mode they check only once
every 1 to 4 hours if the wireless network is active. The backup battery will prevent the
sensors from falling asleep. Note that the communication with the SENSIT server software
is not maintained with this backup battery.
Connect the backup battery to its connector just before connecting the AC mains power
supply.
Figure 21: Backup battery connection
5.4.3
POWER SUPPLY
Connect an AC mains power supply to the Data Collector GPRS.
Input requirements: 100 – 240VAC 50/60Hz.
Figure 22: Power supply connection
30/92
SENSIT SYSTEM | MANUAL
Installation Data Collector
5.4.4
SIM CARD
Push the small button (see yellow arrow) with a small screwdriver or pin, to eject the SIM
card holder from the modem. Insert the SIM card and slide it back into the modem housing.
For details about the GPRS configuration, see chapter 6.2.
Note
Make sure your remove the
pin code from your SIM-card
e.g. by using your mobile
phone.
Figure 23: SIM Card installation
5.4.5
ANTENNA
The Data Collector is featured with two antennas. One for communication with the SENSIT
nodes and the other is the GPRS antenna.
31/92
SENSIT SYSTEM | MANUAL
Data collector Configuration
DATA COLLECTOR CONFIGURATION
6.1
TCP/IP CONFIGURATION
The standard Data Collector has on-board TCP/IP communication. The TCP/IP
communication is used to send the messages from the SENSIT vehicle detections sensors to
the SENSIT Interface Software running on the server.
The default fixed IP-address for the Data Collector is 192.168.1.2. Configuration can be done
using a web browser. Click OK when the Authentication popup appears.
Next the SENSIT server settings should be configured. These settings are provided to you
when the SENSIT Interface Software (SIS) is installed on the server.
Figure 24: Data Collector TCP/IP configuration
Enable the standard Data Collector to automatically establish the connection with the
SENSIT Interface Software running at the server:
Channel 1 – Connection - Connect Mode - Active Connection: Auto Start.
Setup the SENSIT Server IP-address and port-number:
Channel 1 – Connection - Endpoint configuration - Auto increment for active connect: check
Channel 1 – Connection - Endpoint configuration - Remote Host: 
Channel 1 – Connection - Endpoint configuration - Remote Port: 
Note
The Data Collectors
automatically connect to the
server via internet. Please
make sure that the IP-address
and assigned port is open in
your firewall.
Click OK to confirm the settings.
Click Apply settings to write the settings into the Data Collector.
32/92
SENSIT SYSTEM | MANUAL
Data collector Configuration
6.2
GPRS CONFIGURATION
The GPRS modem inside the Data Collector GPRS needs to be configured before it can
access the internet and connect to the SENSIT Interface Software at the server. This is done
by sending 2 SMS text messages to the Data Collector GPRS. Any GSM cell phone can be
used to send these configuration text messages.
First the APN settings should be configured. These settings depend upon the mobile
network provider. The settings are sent in a SMS message using the following format:
PROFILE:APN=;APNLOGIN=;APNPASSWORD=;DNS=;
Where:




APN (Access Point Name)
User name
Password
DNS (Domain Name Server)
Example:
PROFILE:APN=gprsinternet;APNLOGIN=gprs;APNPASSWORD=;DNS=;
Next the SENSIT server settings should be configured. These settings are provided to you
when the SENSIT Interface Software (SIS) is installed on the server. The settings are sent in
a SMS message using the following format:
Note
Make sure the SMS does not
get longer than the default
message size of 160
characters.
PROFILE:HOSTNAME=;PORT=;SSL=;
Where:

SENSIT server hostname or ip-address

Port number

true / false depending if SSL security is
used.
Example:
PROFILE:HOSTNAME=217.114.111.246;PORT=10000;SSL=false;
6.3
GPRS MODEM LED BEHAVIOR
At the GPRS modem there is an indication LED (see yellow circle) that gives you some
feedback about the status of the GPRS modem. It is a dual color LED; red and amber.
Figure 25: GPRS Modem status LED
33/92
SENSIT SYSTEM | MANUAL
Data collector Configuration
6.3.1
RED LED
If the LED flashes red a packet is transmitted.
6.3.2
AMBER LED
Below you can find a description of the behavior of the amber colored LED:

Permanently off
Modem is in one of the following modes:
Power Down, Airplane, Charge Only, Non-Cyclic Sleep Or Cyclic Sleep

600 ms on / 600ms off
Limited Network Service:
No SIM card inserted, no PIN entered, network search in progress, ongoing user
authentication or network login in progress.

75 ms on / 3 s off
IDLE mode:
The modem is registered to the GSM network. No call is in progress.

75 ms on / 75 ms off / 75 ms on / 3 s off
The modem is actively connected to the GPRS network. In this state the modem is
able to communicate with the SENSIT Server.
6.4
VERIFY COMMUNICATION
Via the SENSIT Interface Software (SIS) a more detailed description can be found in chapter
13.1. After choosing: Detection Data Collector choice at the left side of the screen. The
powered and to the internet connected Data Collector, should show up automatically in the
Data Collectors connected list.
34/92
SENSIT SYSTEM | MANUAL
Mounting The Relay Node 2G
MOUNTING THE RELAY NODE 2G
7.1
SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and repair:

The Relay Node only be installed and serviced by qualified service personnel.

To be sure of safety, do not modify or add anything to the SENSIT Relay Node 2G
other than mentioned in this manual or indicated by Nedap N.V.
7.2
FCC AND IC DECLARATIONS
FCC ID: CGDRELAY and IC: 1444A-RELAY
Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada.
L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune
interférence, et (2) cet appareil doit accepter n'importe quelle interférence, y inclus
interférence qui peut causer une opération non pas voulu de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could
void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20cm
separation distance between the antenna and all persons.
Information to the User (Part 15.106(b))
Note: This equipment generates, uses and can radiate radio frequent energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
35/92
SENSIT SYSTEM | MANUAL
Mounting The Relay Node 2G
7.3
DIMENSIONS
See Figure 26 for the dimensions (in mm) of the Relay Node 2G unit.
Figure 26: Dimensions Relay Node 2G (mm)
7.4
INSTALLATION CONDITIONS
The installation recommendation is based on the following environmental conditions;

Dry weather conditions.
7.5
REQUIRED INSTALLATION MATERIALS
The following would be required for mounting of the SENSIT Relay Node 2G.

Special Equipment: Ladder, Bucket-truck or an aerial platform

TORX screw driver: T20

Allen key:
no. 5

Wrench:
size 10
36/92
SENSIT SYSTEM | MANUAL
Mounting The Relay Node 2G
7.6
INSTALLATION PROCEDURE
Below the mounting procedure for the Relay Node 2G. The Relay Node 2G features visual
status feedback using two LED indicators: a green and a red LED.
SENSIT Relay Node 2G mounting procedure
Step 1:
Mounting
Mount the reflector and top of the housing
on the pole or wall. With the Nedap asterisk
at the top. The Relay Node 2G can also be
mounted without the reflector for an omnidirectional radiation pattern.
Step 2:
Power the Relay
Node
Remove the isolation tabs, to power up the
Relay Node.
Step 3:
Verify start-up
Green LED starts blinking fast (duration: 15
sec.), indicating that battery power has
been connected correctly.
Note
The Green and Red feedback
LED’s are located in the
yellow circle.
Step 4:
WSN search
Red LED starts to blink slowly. This
indicates that the Relay Node didn’t found
an active WSN (wireless SENSIT Network)
yet. It is searching for a WSN.
Note
After 15 minutes LED
feedback is turned off, to save
battery power.
Step 5:
WSN found
Green LED starts slow blinking and red LED
is turned off. This indicates that a WSN has
been found.
Note
After 1 minute the LED
feedback is turned off, to save
battery power.
Step 6:
Final installation
Now the Relay Node electronics can be
installed at the pole or wall with a TORX
(T20) screw driver.
37/92
SENSIT SYSTEM | MANUAL
Mounting The Relay Node 2G
7.7
BATTERY REPLACEMENT
When the battery life of the Relay Node 2G fails after specified lifetime, the batteries can be
changed make sure you use the right batteries:
D-cell Lithium Thionyl Chloride batteries (Li-SOCl2) 3.6V, recommended types are:

SAFT | LS 33600

XENO | XL-205F
SENSIT Relay Node 2G battery replacement
Step 1:
Opening the housing
Open the Relay Node 2G housing by
unscrewing the TORX, T20 screw.
Step 2:
Replace the batteries
Remove the old batteries and dispose
them in the correct manner. Place the
new 3.6V Lithium (Li-SOCL2) batteries
(see suggested types above) and make
sure the polarity is correct, as indicated.
Step 3:
Verify start-up
Green LED starts blinking fast (duration:
15 sec.), indicating that battery power
has been connected correctly.
Step 4:
WSN search
Red LED starts to blink slowly. This
indicates that the Relay Node didn’t
found an active WSN (wireless SENSIT
Network) yet. It is searching for a WSN.
Note
After 15 minutes LED
feedback is turned off, to save
battery power.
Step 5:
WSN found
Green LED starts slow blinking and red
LED is turned off. This indicates that a
WSN has been found.
Note
After 1 minute the LED
feedback is turned off, to save
battery power.
Step 6:
Final installation
Now the Relay Node electronics can be
installed at the pole or wall with a TORX
(T20) screw driver.
Note
The Green and Red feedback
LED’s are located in the
yellow circle.
38/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT IR
MOUNTING THE SENSIT IR
8.1
SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and repair:

The SENSIT IR may only be installed and serviced by qualified service personnel.

To be sure of safety, do not modify or add anything to the SENSIT IR other than
mentioned in this manual or indicated by NEDAP N.V.
8.2
FCC AND IC DECLARATIONS
FCC ID: CGDSENSNODE and IC: 1444A-SENSNODE
Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada.
L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune
interférence, et (2) cet appareil doit accepter n'importe quelle interférence, y inclus
interférence qui peut causer une opération non pas voulu de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could
void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20cm
separation distance between the antenna and all persons.
Information to the User (Part 15.106(b))
Note: This equipment generates, uses and can radiate radio frequent energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
39/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT IR
8.3
DIMENSIONS
The SENSIT IR is designed for mounting into the floor of a parking space. See Figure 27 for
the dimensions of the unit in mm.
Figure 27: Dimensions SENSIT IR (mm).
8.4
INSTALLATION CONDITIONS
The installation recommendation is based on the following environmental conditions;

Ambient temperature between 5 to 40 °C (41 to 104 °F0

Dry weather conditions

Surface based on concrete, asphalt or pavement
8.5
REQUIRED INSTALLATION MATERIALS
The following would be required for mounting of the SENSIT IR.

Equipment:
Automatic core drill

Drill size:
Dimensions Ø 85 mm (3.35 in)

Drill depth:
55 mm (2.16 in)

Filler material:
Liquid rapid mortar

Required amount per sensor:
Approx 100 ml
We have good results with the rapid mortar TM 5R. See appendix B for specifications.
Ensure to follow the guidelines and instructions as outlined on the filler material.
40/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT IR
8.6
INSTALLATION PROCEDURE
Below the mounting procedure for the SENSIT sensor.
SENSIT sensor mounting procedure
8.7
Step 1:
Preparation
Indicate on the closed parking lot where the
SENSIT sensor should be mounted. Distribute
the SENSIT sensors over the parking lot and
write down the correct ID numbers on your
installation plan.
Step 2:
Drilling
Drill a hole of Ø 85 mm [3.35 in] and at least 55
mm [2.16 in] deep into the centre of the parking
bay
Step 3:
Gluing
Apply the right amount of filler and pour into the
hole.
Step 4:
Mounting
Double-check the node ID number and the
parking bay on the installation plan and place the
SENSIT sensor into the hole.
Step 5:
Cleaning-up
After mounting the SENSIT sensors in all parking
bays or a selection of parking bays. Clean up the
parking bays and remove all (metal) tools and
objects.
Step 6:
Activating
All SENSIT sensors are set into transport/stock
mode during shipment. After installation all
mounted SENSIT sensors must be swept with
the reset magnet.
Step 7:
Calibrating
After installation the SENSIT sensor must be
calibrated. Ensure that the parking space is
empty and that there is no car parked on top of
the sensor or on neighboring parking bays.
SENSIT sensors can be calibrated via the SENIST
Interface Software (SIS). See chapter 13.6.6 for
more information about calibration.
Step 8:
Glue curing
Leave the filler harden for 8 hours before
vehicles are allowed in the parking space again.
Note
Take attention that you fixate
the SENSIT sensor during the
curing time otherwise the
sensor will start to float.
Note
Once out of the
transport/stock mode the
battery lifetime starts to
count.
Note
When the SENSIT sensors are
not calibrated they hardly
send any messages. This is
due to the fact that there are
no events generated because
the magnetic thresholds are
not crossed.
REPLACEMENT
When the battery life of the SENSIT IR fails after specified lifetime, we advise to replace the
unit completely. The SENSIT IR is fully sealed and for outdoor use, therefore batteries
cannot be replaced.
Drill out the old SENSIT IR and complete the mounting procedure as describe in the
previous paragraph.
Ensure to note the node ID number of the SENSIT IR to the parking bay. Update the parking
bay configuration list in the SIS software to ensure the new sensor is linked to the right
parking bay.
41/92
SENSIT SYSTEM | MANUAL
mounting The SENSIT Flush Mount
9 MOUNTING THE SENSIT FLUSH MOUNT
9.1
SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and repair.
 The SENSIT Surface Mount may only be installed and serviced by qualified service
personnel.
 To be sure of safety, do not modify or add anything to the SENSIT Surface Mount
other than mentioned in this manual or indicated by NEDAP N.V.
9.2
FCC AND IC DECLARATIONS
FCC ID: CGDSENSNODE and IC: 1444A-SENSNODE
Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada.
L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune
interférence, et (2) cet appareil doit accepter n'importe quelle interférence, y inclus
interférence qui peut causer une opération non pas voulu de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could
void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20cm
separation distance between the antenna and all persons.
Information to the User (Part 15.106(b))
Note: This equipment generates, uses and can radiate radio frequent energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
42/92
SENSIT SYSTEM | MANUAL
mounting The SENSIT Flush Mount
9.3
DIMENSIONS
The SENSIT Flush Mount is designed for full mounting into the floor of a parking space. As
the unit is fully flush with the road surface the unit is snow plough resistant. The SENSIT
Flush Mount is only featured with magnetic detection. See Figure 28 for the dimensions of
the unit in mm. The top of the SENSIT Flush Mount is laser engraved with the node ID
number.
Figure 28: Dimensions SENSIT Flush mount (mm).
9.4
INSTALLATION CONDITIONS
The installation recommendation is based on the following environmental conditions;

Ambient temperature between 5 to 40 °C [41 to 104 °F]

Dry weather conditions

Surface based on concrete, asphalt or pavement
9.5
INSTALLATION MATERIAL
The following would be required for mounting of the SENSIT FLUSH MOUNT.

Equipment:
Automatic core drill

Drill size:
Dimensions Ø 85 mm (3.35 in)

Drill depth:
75 mm (2.95 in)

Filler material:
Liquid concrete mortar

Required amount per sensor:
Approx. 100 ml
We have good results with the rapid mortar TM 5R. See appendix B for specifications.
Ensure to follow the guidelines and instructions as outlined on the filler material.
43/92
SENSIT SYSTEM | MANUAL
mounting The SENSIT Flush Mount
9.6
INSTALLATION PROCESS
Installation process as described in paragraph 8.6, however with above mentioned drilling
depth. See figure below for more details about the mounting depth of the SENSIT Flush
Mount, dimensions in mm.
Figure 29: Mounting depth SENSIT Flush mount (mm).
9.7
REPLACEMENT
When the battery life of the SENSIT Flush Mount fails after specified life time, we advise to
replace the unit completely. The SENSIT Flush Mount is fully sealed, therefore batteries
cannot be replaced. Drill out the old SENSIT Flush Mount and complete the mounting
procedure as described in paragraph 8.6.
Ensure to note the node ID number of the SENSIT IR to the parking bay. Update the parking
bay configuration list in the SIS software to ensure the new sensor is linked to the right
parking bay.
44/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT Surface Mount
10
MOUNTING THE SENSIT SURFACE MOUNT
The SENSIT Surface Mount is designed for installations where the sensors cannot be drilled
into the parking space e.g. multi storey car parks and rooftop car parks or existing car parks.
10.1 SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and repair.

The SENSIT Surface Mount may only be installed and serviced by qualified service
personnel.

To be sure of safety, do not modify or add anything to the SENSIT Surface Mount
other than mentioned in this manual or indicated by NEDAP N.V.
10.2 FCC AND IC DECLARATIONS
FCC ID: CGDSENSITSM and IC: 1444A-SENSITSM
Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada.
L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune
interférence, et (2) cet appareil doit accepter n'importe quelle interférence, y inclus
interférence qui peut causer une opération non pas voulu de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could
void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20cm
separation distance between the antenna and all persons.
Information to the User (Part 15.106(b))
Note: This equipment generates, uses and can radiate radio frequent energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
45/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT Surface Mount
10.3 DIMENSIONS
The SENSIT Surface Mount can easily be glued onto the surface of a parking space. The unit
consists of two components;

Sensor core; the black core is the vehicle detection sensor. This unit can be
replaced after end of battery life.

Mounting ring; the mounting ring allows easy installation onto the surface of a
parking space.
See Figure 30 for the dimensions of the unit, dimensions in mm. The top of the SENSIT
Surface Mount is laser engraved with the node ID number.
Figure 30: Dimensions SENSIT Surface Mount (mm).
10.4 REQUIRED INSTALLATION MATERIALS
The following would be required for mounting of the SENSIT FLUSH MOUNT.

Equipment:
Pneumatic kit dispenser

Filler material:
MSP or PU glue

Required amount per sensor:
Approx. 150 ml
Note
See Appendix 16B and 16C for
more information about the
recommended MSP or PU
glue.
46/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT Surface Mount
10.5 INSTALLATION PROCESS
Follow the recommended installation procedure for the SENSIT Surface Mount as described
below.
SENSIT Surface Mount mounting procedure
Step 1:
Preparation
Indicate on the closed parking lot where the
SENSIT sensor should be mounted. Clean the
location where the sensor should be mounted.
Distribute the SENSIT sensors over the parking
lot and write down the correct ID numbers on
your installation plan.
Step 2:
Gluing
Pour the filler into the mounting ring of the
SENSIT Surface Mount. A pneumatic kit
dispenser makes it easy to apply the glue into
the mounting ring. For good fixture with the
surface please fill the entire mounting ring.
Step 3:
Mounting
Press firmly and double check the ID number.
Step 4:
Cleaning-up
After mounting the SENSIT sensors in all
parking bays or a selection of parking bays.
Clean up the parking bays and remove all
(metal) tools and objects.
Step 5:
Activating
All SENSIT sensors are set into transport/stock
mode during shipment. After installation all
mounted SENSIT sensors must be swept with
the reset magnet.
Step 6:
Calibrating
After installation the SENSIT sensor must be
calibrated. Ensure that the parking space is
empty and that there is no car parked on top of
the sensor or on neighboring parking bays.
SENSIT sensors can be calibrated via the
SENIST Interface Software (SIS). See chapter
13.6.6 for more information about calibration.
Step 7:
Glue curing
Leave the glue dry for at least 4 hours before
vehicles are allowed in the parking space again.
Note
Ensure excessive glue is
removed from the bottom
black core part of the unit, as
this will make it very difficult
to replace the core part.
For non-permanent mounting
only glue the ring with a few
dots of glue.
Note
Once out of the
transport/stock mode the
battery lifetime starts to
count.
Note
When the SENSIT sensors are
not calibrated they hardly
send any messages. This is
due to the fact that there are
no events generated because
the magnetic thresholds are
not crossed.
47/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT Surface Mount
10.6 REPLACEMENT
When the battery life of the SENSIT Surface Mount fails after specified lifetime, we advise
to replace the core. The core part of the SENSIT Surface Mount is fully sealed and for
outdoor use, therefore batteries cannot be replaced.
SENSIT Surface Mount replacement procedure
Step 1:
Remove core
The mounting ring can remain positioned in the
parking space. The core can be unscrewed using
a TORX screwdriver. Unscrew the core by
opening the 4 screws in the core part of the
SENSIT Surface Mount using a T20 size bit
screwdriver. Twist the core to lift up.
Step 2:
Replace core
Place a new core into the mounting ring by
aligning the marks on the core part with the
marks on mounting ring as indicated in figure 9.
Strongly push down the core and secure with 4
screws. Write down the correct ID numbers of
the replaced core on your installation plan.
Step 3:
Activating
All SENSIT sensors are set into transport/stock
mode during shipment. After installation all
mounted SENSIT sensors must be swept with
the reset magnet.
Step 4:
Calibrating
After installation the SENSIT sensor must be
calibrated. Ensure that the parking space is
empty and that there is no car parked on top of
the sensor or on neighboring parking bays.
SENSIT sensors can be calibrated via the
SENIST Interface Software (SIS). See chapter
13.6.6 for more information about calibration.
Step 5:
Update SIS
Ensure to note the node ID number of the
SENSIT Surface Mount to the parking bay and
update the parking bay configuration list in the
SENSIT Interface Software (SIS), see chapter
13.6.2
Note
Once out of the
transport/stock mode the
battery lifetime starts to
count.
Note
Also ensure not metal parts
(such as tools) aren’t
positioned in the surrounding
of the sensors as this might
affect calibration.
Note
When the SENSIT sensors are
not calibrated they hardly
send any messages. This is
due to the fact that there are
no events generated because
the magnetic thresholds are
not crossed.
48/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT EPL
11
MOUNTING THE SENSIT EPL
The SENSIT EPL is designed for installations at the windscreen of a vehicle.
11.1
SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and repair.

The SENSIT EPL may only be installed and serviced by qualified service personnel.

To be sure of safety, do not modify or add anything to the SENSIT EPL other than
mentioned in this manual or indicated by NEDAP N.V.
11.2 FCC AND IC DECLARATIONS
FCC ID: CGDSENSITEPL and IC: 1444A-SENSITEPL
Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada.
L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune
interférence, et (2) cet appareil doit accepter n'importe quelle interférence, y inclus
interférence qui peut causer une opération non pas voulu de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could
void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20cm
separation distance between the antenna and all persons.
Information to the User (Part 15.106(b))
Note: This equipment generates, uses and can radiate radio frequent energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
49/92
SENSIT SYSTEM | MANUAL
Mounting The SENSIT EPL
11.3
DIMENSIONS
The SENSIT EPL can easily be mounted on the inside of a vehicle. Clean the inside surface
of the windshield and make sure it free of grease and dirt. Than attaches, the SENSIT EPL
with the suction cups to the windscreen. See Figure 31 for the dimensions of the unit,
dimensions in mm. The bottom of the SENSIT EPL is laser engraved with the node ID
number.
Figure 31: Dimensions SENSIT EPL (mm).
11.4 REQUIRED INSTALLATION MATERIALS
The following would be required for mounting of the SENSIT EPL.

Equipment:
Soft lint free cloth

Cleaner material:
Isopropyl alcohol
11.5 INSTALLATION PROCESS
Follow the recommended installation procedure for the SENSIT EPL as described below.
SENSIT Surface Mount mounting procedure
Step 1:
Preparation
Write down the unique ID-number of the
SENSIT EPL and insert the AAA alkaline
batteries.
Step 2:
Cleaning
Clean the windscreen at the location you like to
install the SENSIT EPL.
Step 3:
Mounting
Attach the SENSIT EPL with the suction cups to
the windscreen.
Step4:
Registration
Register the SENSIT EPL in the SIS by filling in
the permit details and the by Step1 written
unique ID-number, this explained in more
details in chapter 13.4.1.
50/92
SENSIT SYSTEM | MANUAL
Project Support
12
PROJECT SUPPORT
Based on our thorough project analysis including configuration and installation advice we
can offer the customer the best AVI solution.
12.1 SITE SURVEY & INSTALLATION ADVICE
This will consist of an engineer visiting the site to visually inspect and analyze the location.
We will then carry out calculations and provide you with detailed configuration and
installation advice for the equipment for a specific project.
12.2 ON-SITE CERTIFICATION
An engineer will visit the site to inspect the installation of the equipment on reliable and
accurate detection. Nedap engineers are not involved in installation (wiring) of any
equipment. The installation must be completed before the engineer arrives on-site. We will
ensure that the operation confirms our commissioning requirements, only on condition of
prior given installation advice.
51/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13
SENSIT INTERFACE SOFTWARE
13.1
INTRODUCTION
The SENSIT Interface Software (SIS) enables easy system integration into an enforcement,
traffic guidance or parking guidance management application.
The SENSIT Interface Software enables easy installation of the wireless sensor network.
Once the network and sensors are installed and calibrated, the sensors will automatically
appear in the software. Configuration of sensors to specific parking bays, parking zones and
parking lot can easily be realized.
Additionally the software configures and monitors communication of the SENSIT node
network. It monitors the data transfer between the sensors and the Data Collectors.
Moreover it also analyzes communication reliability of the sensor network in a graphical
map, automatically alerting areas for maintenance.
The SENSIT Interface Software is installed on a hosted server, so no IT infrastructure is
required at the client. The software application can be approached with any modern web
browser that supports Java can connect to the software application.
Each sensor site has a site specific URL indicated in the following way;
https://sitename.nedapparking.com
13.2 USERS
Start the web browser and enter the SENSIT Server hostname. A login screen will appear.
Please view the document outlining the Data Collector configuration settings for the details
on the URL, login and password for your site. This information is required to obtain access.
13.2.1 LOGIN
The login screen provides access to the software. Enter username and password.
Figure 32: Login screen
52/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
Default logins are:
User: sensit
The SENSIT user has reduced functionality in the software. Only a subset of these options is
available via the user login. Basically this login is available to check the status of the system.
It does not allow changing the configuration or any other settings.
User: parkingapp
This login has reduced functionality in the software and is used for the Nedap parking app.
User: integrator
This user has reduced functionality in the software, used for third party integration via REST
or SOAP.
User: sensitadv
This user has advanced functions and configuration possibilities.
The initial username and password are provided to you by Nedap.
13.2.2 LOGOUT
Click 'Logout' when you want to close the application.
13.3
DASHBOARD
The Dashboard is designed to give the user an overview on how the SENSIT system is
performing. The Dashboard page contains several Widgets. A Widget summarizes and
displays the actual state of SENSIT system.
Figure 33: Dashboard screen
The Dashboard contains six main Widget categories: SENSIT sensor, Relay Nodes, Data
Collectors, The wireless Network, the Server and system notifications.
The functions of the Dashboard are self-explaining by hover over pop-ups and help balloons
53/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
when needed. Every widget can be configured via the configuration symbol at the right
corner of every widget, see figure below. The configuration symbol will automatically show
if you move your mouse to the specific widget. In this screen you can change the different
widget settings.
Note
Configuration is only available
under sensitadv login.
Figure 34: Configuration symbol and widget settings screen
13.4 PARKING ENFORCEMENT
The Parking enforcement is a secondary dashboard, designed to give the user an overview
on all parking enforcement related information. This parking enforcement dashboard
summarizes and displays the actual status of a specific parking zone.
Figure 35: Parking enforcement dashboard screen
Different enforcement information of all parking zones are displayed: Permits in use,
Occupied permit bays, Occupied bays, Bays in overstay and the Permit violations.
The Electronic Parking License (EPL) is a hardware device that is physically placed inside a
vehicle or it is an App that is running on a smartphone. Whenever the vehicle with EPL
hardware stops moving for a specific period of time, the EPL considers the vehicle to be
parked. In that case, the EPL hardware will search for a SENSIT wireless network. If a
network is detected, the EPL will make itself known to the network. As a result the unique
EPL identifier is registered within the SENSIT Server system. The user of the EPL App is
doing the same, it activates the parking action with it smartphone.
54/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
When a parking bay that requires a license, becomes occupied, the SENSIT system is
notified. The system will calculate the odds of the parking bay being occupied by an
unauthorized vehicle.
13.4.1 PERMIT ADMINISTRATION
In these screens all permit administration is performed. A permit is issued to a person and it
can be a hardware EPL or an EPL App installed on a smart phone.
Figure 36: Permit administration screen
New permits can be added and existing permits can be edited or removed. A Residential
permit number can be enter, name, license plate number and the EPL node ID in case of a
issued hardware EPL. The permit can be disable and an expiration date can be used, an
empty expiration date means valid forever. Than one or multiple parking zones can be
selected where the permit is valid. Zone creation is explained in the next paragraph.
Figure 37: Edit permit screen
After creating a new permit, by filling in all needed details, a QR-code is automatically
55/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
generated. The EPL App needs this QR-code. The QR-code contains the URL of the SIS
where the permit is created and a unique identifier.
13.4.2 PERMIT ZONE CONFIGURATION
In these screens all permit zone configuration is performed. A permit zone is a selection of
one or multiple parking bays. A list of all available, already entered, zones are displayed in
the screen below.
Figure 38: Permit zone configuration screen
New permit zones can be added and existing permits zones can be edited or removed. A
permit zone name and description can be entered and the bays can be assigned in the
selection screen.
Figure 39: Add/Edit a permit zone screen
A permit zone can be a parking lot(s), a parking zone(s), one or a selection of bays. This can
easily be selected in the screen below.
Figure 40: Permit zone bays assignment screen
56/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13.5 DETECTION
13.5.1 DATA COLLECTOR
In the Data Collector menu you can configure communication gateway settings between
the Data Collectors and the SENSIT Server. Furthermore the screen provides an overview of
the current Data Collector settings. The list of Data Collectors is automatically updated.
Gateway server setting
Select 'enabled' to enable the connection from Data Collector to the server. Enter the TCP
port (or SSL port), to accept connections from the Data Collector(s). For a remote hosted
SENSIT Server, the port number should not be changed. Because the port numbers are
assigned by the Nedap system administrator.
Data Collector connection settings
In this menu you can set 'Host name' and communication 'Port' for the Data Collector. The
Data Collector is displayed as a node, see below. The hostname of the Data Collector can
normally be found on the housing. The SENSIT Server will try to establish a connection with
the specified Data Collector. This does not work on remote hosted SENSIT Servers. See
gateway server settings above.
The screen provides an overview of the current Data Collector settings. When entering new
Data Collectors, the table is automatically updated.
Figure 41: Data Collector gateway server settings
13.5.2 NODE CROSS CHECK
The menu option 'Node cross check' displays all nodes currently visible in the system that
are not allocated to a parking bay. These could be new or replaced SENSITs, but also the
Relay Nodes and Data Collectors are shown here. Moreover this screen also displays parking
bays without a node (if this information is entered via the parking bay configuration).
Figure 42: Node cross check
57/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13.5.3 NODE PRESENCE
This screen will display information on the last received message from each node present in
the network. It will outline the Node ID, type number, version and the timestamp of the last
received message.
Node presence check (min)
If a node does not respond within a certain time period after transmission of the last
message, the SENSIT Server will check if the node is still available. In this menu option you
can select the time after receiving the last message (in minutes) when to send the Node
presence check.
Node presence check retry
The 'Node presence check retry' specifies the number of times the SENSIT Server shall try
to connect to the node.
Figure 43: Node presence
In the screenshot above several nodes are listed in the node cross check.
For example node id 00.0000.72BC is a SENSIT IR (type 3109). Every different type of node
has its own Type code, see below the general use types:
Type code
Node description
000c
Data Collector
0018
Relay Node 2G
3003
Relay Node 1G
3109
SENSIT Flush Mount or SENSIT IR
310D
SENSIT Flush Mount or SENSIT IR
310E
Electronic Parking License (EPL)
8004
WSN Display
13.6 DEFINITION
13.6.1 RELAY NODE CONFIGURATION
You can click the Refresh button and verify if the Relay Node ID appears in the Current
Relay Nodes list.
Figure 44: Relay Node configuration screen
58/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
The Relay Node ID is laser engraved on the Relay Node. There is also a 125kHz passive RFID
label embedded into the Relay Node. This can be used for verification of the Relay Node or
to localize Relay Nodes that are already installed in the field.
13.6.2 PARKING BAY CONFIGURATION
In the menu 'Parking bay configuration' SENSITs are allocated by their Node ID to individual
parking bays.
The data is imported into the system via a csv-file (comma separated values). The following
information should be entered into the csv-file separated by a comma (' , '). Note that the
combination of parking lot-id and bay-number must be unique.
Column 1
Column 2
Column 3
Column 4
Column 5
Column 6
Column 7
Note
Ensure that the filename and
file path do not include any
spaces.
Parking lot ID (number indicating the parking lot).
Zone ID (number indicating zone on the parking lot the bay is located in)
Zone ID is also used to identify Relay Nodes (RN) or Data Collectors (DC).
Bay number (number indicating individual parking bay).
Bay number is also used to number a Relay Node or Data Collector
Node ID. (SENSIT, Relay Node or Data Collector)
GPS, Latitude (optional, in decimal degrees with max. 6 decimals).
GPS, Longitude (optional, in decimal degrees with max. 6 decimals).
GPS, Altitude (optional, in decimal degrees with max. 6 decimals).
Figure 45: Example parking bay configuration csv-file
Select the csv-file by clicking the 'Browse'-button, then click 'Import' to import the selected
file.
When the csv-file is imported, the screen will display the information. At each given
moment you can verify in this table the allocated SENSIT / Parking bay bindings. Refer to
the node cross check display to verify if all SENSIT are assigned to a parking bay (see
chapter 13.5.2). It is possible to incrementally expand the Parking bay configuration list by
importing only additional allocation information (Parking lot ID, Zone ID, bay/place number
and Node ID) via a new csv-file.
Figure 46: Parking bay configuration
59/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
Click the small green checkbox icon to (temporarily) inform the system that the parking bay
is unavailable. Click the small pencil at the end of a row, an Update Node ID screen shows
up, here you can change the Node ID number and the GPS coordinates. This can be used to
replace a SENSIT or to correct a mistake.
Figure 47: Update Node ID
13.6.3 PARKING LOT CONFIGURATION
The parking state logging feature periodically saves occupancy status in the database. This
feature must be enabled for the occupancy chart feature described in chapter 13.8.2.
Enable the 'parking lot state logging on' checkbox to start logging occupancy status of the
parking lot in the database. The parking lot state logging interval setting selects the logging
period in minutes. By default this is set to 60 minutes.
Figure 48: Parking lot configuration
13.6.4 MONITOR CONFIGURATION
Site Name
Fill in here the site name.
Monitor Color Mapping
Configure here the color mapping for the actual monitor status (free, occupied, overstay,
and disabled).The selected colors are used in the monitor screen.
Map List
Here you can load the parking lot graphic file (SVG-format) into the system and assign it to
a parking lot. The SVG-file can be created with Inkscape (http://inkscape.org). Nedap has an
extension available for Inkscape that should be used to define where the parking bays are
located on the map. See the advanced section, chapter 14.1 for more explanation and the
workflow about the Inkscape program.
When the SVG-file is created, enter the ParkinglotID and the title. Then select the svg-file
by clicking the 'Browse'-button and click Upload' to upload the selected file into the system.
60/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
Figure 49: Inkscape
13.6.5 OVERSTAY CONFIGURATION
The SENSIT Server can be used for overstay applications, specifically where there is a need
for a maximum time limit for free parking. The menu 'Overstay configuration' allows you to
set several overstay parameters.
Figure 50: Overstay configuration
System overstay settings
With this option the global overstay function can be enabled. The settable Allowed parking
time is the overstay time for all SENSIT sensors defined at the SENSIT Interface Server. This
setting determines how long a parking bay should be occupied before an overstay situation
occurs.
Overstay verification settings
When enabled, the SENSIT Interface Server will ask the SENSIT sensor if all state events are
received in case of an overstay. The last state event message is transmitted again to the
SENSIT Server to verify the overstay.
The Max number of retries (max value is 5) can be set. If an overstay verification fail it retry
to receive the last state event message. If the final overstay verify attempts fail an
unverified overstay event is generated.
61/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13.6.6 SENSOR CALIBRATION
To ensure reliable operation of the system the SENSIT sensors should be calibrated before
commissioning. Calibration values can be set for the magnetic detection in each axis (x, y
and z). Default calibration values are 50 mGauss in each axis. The default value for the IR
sensitivity is 9, the maximum. The IR sensitivity is only lowered in case of a ceiling or other
coverage of the SENSIT sensors.
Note
The SENSIT nodes can only be
calibrated when the specific
bay and neighboring bays are
not occupied by vehicle. When
all SENSIT nodes need to be
calibrated the parking lot
must be completely empty.
Figure 51: SENSIT sensor calibration
SENSIT nodes can be calibrated individually. This by entering the Node ID of the specific
sensor you want to calibrate into the field 'Calibrate node number'.
Alternatively you can calibrate all nodes or the nodes from a specific parking lot. When you
click 'Calibrate all nodes' all SENSIT sensors in the network will automatically be calibrated.
Click the 'Calibrate' button to start the calibration. In the menu an update message will start
to keep you update on progress.
Incorrect occupied spaces can be indicated if a vehicle parked in the neighboring parking
space activates the magnetic sensor. If the percentage of incorrect occupied (so actually
free) is too high over the parking lot, the magnetic values can be adjusted by selecting a
higher value e.g. 60 mGauss. If the percentage of incorrect free (actually occupied) spaces is
too high the sensitivity of the magnetic threshold can be reduced to lower value e.g. 40
mGauss.
13.6.7 DISPLAY
Display Configuration
The 'Display configuration' screen allows you to control a display via the node network. This
without any physical communication wiring. Only a power supply is required. The
communication with a display is realized via a display node. Note that this functionality is
only available for specific displays. Contact Nedap for more information. The display node is
part of the network and can therefore communicate wirelessly via the node network. A
maximum number of 2 displays can be controlled in a wireless mesh network of 500 sensors.
Use of more displays will increase the communication latency.
62/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
Figure 52: Display configuration
The display will show the total number of available spaces on all the parking zones and
parking lots it has been assigned to. In case you want to display information on individual
zones, we advise you to allocate one display node to each parking zone.
The display configuration information is imported into the system via a csv-file (comma
separated values). The following information should be entered into the csv-file separated
by a comma (' , ').

Column 1
Parking lot ID.

Column 2
Zone ID.

Column 3
Display node ID.

Column 4
Full threshold. When less parking places are available, the
display will indicate FULL.
Figure 53: Example display configuration csv-file
Select the csv-file by clicking the 'Browse'-button, then click 'Import' to import the selected
file.
Display Current View
The display current view shows the actual display information per display node.
Display View Settings
The display view settings allow configuring the weekdays and time periods during which the
display information should be updated. This can be used for example in cases where the
display should be off during night time.
63/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13.7 MONITOR
13.8 OCCUPANCY REPORT
The occupancy report displays the actual number of occupied bays in a parking lot.
Figure 54: Occupancy overview
13.8.1 OCCUPANCY LIST
The occupancy list shows the actual occupancy information per parking bay.
Figure 55: Occupancy list
Please find below a small table, which explains the different symbols:
State
Description
Sensor
Description
Occupied
Optical and Magnetic occupied
Free
Magnetic occupied
Overstay
Optical occupied
Free
64/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13.8.2 OCCUPANCY CHART
The occupancy chart shows a graphical display of the occupancy status of the parking lot
during specified time. By filling in the parking lot ID number and the requested time period.
A graphic will be generated displaying the occupancy of the parking lot. The graphic is
generated based on history stored in the local database.Please note that the occupancy
state logging must be enabled, see chapter 13.6.3.
Figure 56: Occupancy chart
Click and drag in the chart to zoom into more detail.
13.8.3 OVERSTAY REPORT
The overstay report shows all the parking bays that currently are in overstay. Moreover it
also visualizes the parking start time for each parking bay.
Figure 57: Overstay report
13.8.4 PARKING VIOLATION PROBABILITY
The parking violations probability overview shows a list of all occupied parking bays that
require a license. The calculated violation probability is shown.
Figure 58: Parking violations overview
Third party applications can pick up items from this table using the documented SOAP or
REST interface. For more information on specific SOAP commands see the SENSIT
Software Integration Developer Guide. The REST API is explained at the left side under
Documentation. Violations that exceed a certain violation probability threshold can trigger
65/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
enforcement or more generic follow up activity.
13.8.5 MAP MONITOR
The monitor will show the actual parking lot status on an overview map. The SENSIT are
placed on the map and their colors indicate the actual status.
Click on Graph - Sensor Draw Mode to show more sensor information details.
Click on Graph – Network Draw Mode to show network details (green=passive, red=active).
Click on Graph – Network Uptime Mode to show network uptime details (green=good,
red=not good). Status reading must be enabled, see chapter: Status Reading Interval
Settings.
See chapter 13.6.4 how to configure the overview map.
Figure 59: Map Monitor
13.9 DIAGNOSE
13.9.1 ICE DETECT MODE
In this list the automatic global ice detection situation of the system is shown.
Figure 60: Ice detect mode
13.9.2 BATTERY LOW WARNINGS
In this list all SENSIT with a low battery voltage are mentioned. These warnings show up
whenever the battery voltage of a SENSIT drops below the 3 Volt (Alarm level).
Figure 61: Battery low warnings
66/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13.9.3 BATTERY PLOT
This screen gives a graphical overview of the battery voltage of a single SENSIT.
Figure 62: Battery plot
13.9.4 SENSOR ANALYSIS
The sensor analysis is a tool to check the reliable operation of the SENSIT nodes in the
system. The Sensor analysis provides information on the functional operation of a specific
sensor during a specific time period.
The following information is displayed in the chart.

X, Y, Z: Magnetic measurement values for X, Y and Z-axis.

ITP, IRS: Infrared transmitter value (ITP) and infrared receiver (IRS) values
(only for SENSIT IR).

State:
Occupancy state (red = magnetic sensor, blue = infrared sensor)
Click and drag in the chart to zoom into more detail.
Note
The measurement values are
only updated when the
SENSIT sensor transmits an
event to the server.
Figure 63: SENSIT sensor analysis
13.9.5 SENSOR CALIBRATION ERRORS
This screen indicates the SENSIT nodes that do not transmit any state event messages. For
example, an event is created when a vehicle enters the parking bay and a difference in the
magnetic field is has been detected. When the difference in the magnetic field does not
67/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
result in a state change event, in other words no change in the occupancy, this might
indicate that the SENSIT has not properly been calibrated. The screen indicates the number
of events received from a specific SENSIT without a state change.
13.9.6 DATA COLLECTOR CONNECTION LOG
This screen shows a list of all connects and disconnects of the Data Collectors in the system.
Figure 64: SENSIT sensor analysis
13.9.7 BAD NETWORK EVENTS
This table shows all events that a SENSIT generates, when it detects possible problems in
the wireless communication.
Figure 65: Bad network events screen
13.9.8 PENDING TX MESSAGES
This table show all message in the transmit queue.
Figure 66: Pending TX messages screen
13.9.9 PENDING RX MESSAGES
This table show all message in the receive queue.
13.10 SETTINGS
13.10.1 USER SETTINGS
Change Password
In this screen the password of the current logged in user can be changed
68/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
13.10.2 SYSTEM SETTINGS
System Information
The system information menu offers the user the possibility to download log files and to
change system specific settings.
Download log file
This setting is used to provide remote support. The log file contains all the information
required for Nedap's engineers to analyze system information.
Download error log file
This setting is used to provide remote support. The log file contains all the information
required for Nedap's engineers to analyze system information.
Download properties file
The properties file contains all the system settings. This file can be used for support
purposes to verify the system.
Figure 67: System info
System Reboot
Click the 'Reboot'-button to reboot the SENSIT Server.
Time Configuration
Configure here the time zone settings of the SENSIT Server.
Node Gateway List
Here you can activate if a message for a specific SENSIT is only transmitted via the Data
Collector(s) in the Gateway list. In this way only the involved Data Collector(s) are
transmitting the message into the (local) Wireless SENSIT Network and not too all Data
Collectors available in system. If a specific SENSIT doesn’t communicate for in this case 24
hours the Gateway list will be clear for this SENSIT and a message for this specific SENSIT
will be transmitted via all available Data Collectors.
Figure 68: Node gateway list screen
69/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
Local Configuration
Store events in database
Select this option to store events in the database of the SENSIT Server. Normally this
option should be selected.
Recover lost messages
The event messages have a sequence number. With this sequence number, the SENSIT
Server can determine if messages were lost. When this happens the SENSIT Server can ask
the SENSIT to resend these lost messages. Enable the checkbox if this is desired.
Message recovery retry time
Message recovery retry time (in minutes) is the repeat time the system will search for
events it has not yet received. The search will be repeated after the set time.
Restore received messages at startup
Select this option if you want to restore events at SENSIT Server startup.
Number of lost messages to recover at startup
You can select the maximum number of messages you want to recover per node (max. 32
messages).
Sensor select mode
This setting selects which sensor determines the occupied state.
Auto
Sensor is automatically selected using intelligent
algorithms (Recommended setting).
Magnetic
Only the magnetic sensor is used.
Optical
Only the optical (infrared) sensor is used.
MagneticANDOptical
The parking bay is occupied when both sensor detect the
vehicle (magnetic + optical).
MagneticOROptical
The parking bay is occupied when at least 1 of the sensors
detect the vehicle.
Calibrate error after .. magnetic events when occupied
The SENSIT Server registers when both sensors of a SENSIT-IR disagree about the
occupancy state. In automatic mode, the optical sensor has a higher priority. However when
the optical sensor is dirty, this will have a negative result on the accuracy. This setting will
generate a Calibration error when the optical sensor remains occupied while the magnetic
sensor registered state changes several times. See also chapter 13.9.5.
Figure 69: SENSIT local configuration
70/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
Active Http Sessions
In this screen you can see all user logged in to the web-server. All active open web sessions
are shown.
Status Reading Interval Settings
Enable the status reading to make the SENSIT Server request the network performance
statistical counters for every node. Preferably this is done at night when there are relatively
few vehicle movements. The status reading can be shown in the monitor, when selecting
the Network Uptime Mode. See chapter 13.8.5.
Figure 70: Status reading
13.10.3 EXPERT SETTINGS
Console
The Console menu allows you to directly transmit commands to the SENSIT network. It is
not recommended to experiment with the functionalities in this window unless instructed to
you by Nedap technical support engineers.
Figure 71: Console
71/92
SENSIT SYSTEM | MANUAL
SENSIT Interface Software
EPL settings
The matching time window is adjustable and can be set differently for the SENSIT EPL and
the EPL App. This matching time window specifies the allowed time uncertainty of an EPL
or EPL App. Based on this value an EPL or EPL App is included or excluded in the matching
algorithm.
EPL old licenses (deprecated)
Via this old EPL licenses menu it is possible to read the previous EPL administration screens.
This menu will be removed in the next release. The new major release v1.5.x has a new way
of administrating permits; hardware EPL’s or EPL Apps. All administration is now group at
the Parking enforcement dashboard.
72/92
SENSIT SYSTEM | MANUAL
Advance Configuration
14
ADVANCE CONFIGURATION
14.1 INKSCAPE
The maps for the Monitor map at the SIS must be in a Scalable Vector Graphic image. These
SVG-file images can be created with an open-sources program Inkscape
(http://inkscape.org). Nedap has an extension available for Inkscape that should be used to
define where the parking bays, Relay Nodes and Data Collectors are located on the map.
After installing Inkscape and the Nedap Inkscape extensions the program can be started. By
selecting Extensions -> SENSIT -> Create Bay… bays can be added to the drawing and by
selecting Extensions -> SENSIT -> Create Node… nodes (Relay nodes or Data Collectors) can
be added to the drawing. See also the figure below.
Figure 72: Inkscape SENSIT extensions
After selecting the Create bay… option a pop-up window appears, see Figure 73 below. You
can add bays to the drawing. In this way a simple representation of the parking lot can be
created. In this example 6 bays (bay number 1 to 6) are created.
Figure 73: Inkscape, Create Bay
The same for adding Relay Nodes and Data Collectors. By selecting Extensions -> SENSIT ->
Create Node… the Create Node pop-up window appears. In the example below a Data
Collector with ID-number 8AB4 and a Relay Node with ID-number 8A9B is created and
73/92
SENSIT SYSTEM | MANUAL
Advance Configuration
place at the right location in the map.
Figure 74: Inkscape, Create Node
When the drawing is finished the next step is to scale the drawing correctly so all bays, Relay
Nodes and Data Collectors are nicely places in the map. First select al objects, this can be
done easily with Ctrl + A. Select: File -> Document Properties… and then in Custom size,
Resize page to content… add some top, bottom left and right margin to the page and select
the button Resize page to drawing or selection. See also Figure 75 below.
Figure 75: Inkscape, Resize page
After resizing the page the file can be saved as a SVG-file make sure you don’t use spaces in
the filename and after that uploaded to the SIS as described in chapter 6013.6.4.
74/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
15
FREQUENTLY ASKED QUESTIONS
15.1 GENERAL
What types of SENSIT sensors are available and what is the difference?
There are 3 different types of SENSIT sensors available:
SENSIT IR - Magnetic and optical sensor suitable to be built-into the floor of each
parking space.
SENSIT Flush Mount - Magnetic sensor suitable to be built-into the floor of each
parking space.
SENSIT Surface Mount - Magnetic and optical sensor for mounting onto the floor
of a parking space
What is the accuracy of the SENSIT Flush Mount?
The magnetic sensor can achieve an accuracy of 95%.
What is the accuracy of the SENSIT IR and SENSIT Surface Mount?
The combination of the magnetic and optical sensor has an average accuracy of above 98%.
How scalable is the SENSIT system?
The SENSIT system is quite scalable. The theoretical maximum number of SENSIT nodes in
one network is about 65000. In general, large installation need to be divided into smaller
sub-networks (segments), which makes it better manageable and easier to understand.
Sites that have more than 500 sensors or more than 15 Relay Nodes need segmentation.
Please contact your Nedap account manager.
What is the temperature range for the SENSIT and SENSIT IR?
The temperature range for both SENSIT as well SENSIT IR is -40°C to 85°C [-40 to 185°F].
Temperatures below -30°C [-22°F] might affect accuracy of the magnetic sensor. The
accuracy on the optical sensor remains unchanged.
How does the energy efficient Wireless SENSIT Network work?
The medium access protocol is based upon time division multiple access (TDMA). Time is
divided into time slots, which (Relay) nodes can use to transfer data without having to
content for the medium or having to deal with energy wasting collisions of transmissions.
After the frame length, which consists of 16 time slots, the (Relay) node again has a period
of time reserved for it. We have parameterized the duration of a time slot and the number
of time slots. The default timeslot is 100ms and the number of timeslots in a frame is 16. In
the US the system uses also Frequency Hop Spread Spectrum (FHSS); a pseudo random
frequency hopping scheme every timeslot the SENSIT also changes the frequency. In this
way the devices comply with FCC regulations.
If a SENSIT sensor decides to transmit a messages it asks the first Relay Node within reach if
it is allowed to transmit a message to this Relay Node, if allowed the Relay Node will receive
the message from the SENSIT and retransmits this message to the next Relay Node or
directly to the Data Collector.
Can a SENSIT sensor been used to replace a loop detector?
The SENSIT sensor is designed to detect a changes in either optical or earth magnetic field.
A continuous flow of traffic would generate a constant status change. Moreover since the
system is based on wireless communication, communication is slower compared to hard
wired loop. We therefore do not advise to use the SENSIT sensor to replace safety loops for
critical applications.
75/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
15.2 MAGNETIC SENSOR
Is the magnetic sensor influenced by snow or ice?
We have tested the system with about 15 cm (5.9 in) of snow during multiple tests. Snow
did not affect the accuracy of the magnetic performance.
Is the magnetic sensor influenced by dirt?
The magnetic sensor is not influenced by dirt like sand, mud or leafs.
How quickly does the magnetic sensor in the node react to a change in status?
Default the magnetic sensor checks its status change every second.
Can the magnetic sensor ‘see’ the magnetic difference between a car and truck?
In a static parking application a SENSIT sensor cannot observe a difference between a small
vehicle and a large truck. The variation in the earth magnetic field changes under a car or
truck does not depend on the height of the vehicle but on where a car or truck stops. See
also the image below to clarify this in more details.
Image 1: Vehicle & earth magnetic field
Image 2: Truck & earth magnetic field
How does the SENSIT sensor detect a car and changes the magnetic status from free
into occupied?
The magnetic status of the SENSIT sensor has changed if at any axis (X, Y, and Z) changes
more than 50mGauss compared to the stored calibration vector. Normally the earth
magnetic field vector is about 500mGauss. This can vary allot from place to place. In order
to set the SENSIT sensor to local earth magnetic field we advise to calibrate the sensors.
How can I avoid a vehicle driving over the SENSIT sensor to trigger a status change
event message?
When a vehicle is driving over a or multiple SENSIT sensors to reach the final parking bay
the overdriven SENSIT sensors will transmit an occupied and free event message. If the
overdrive filter isn’t set. By default the overdrive filter is set to eliminate these kinds of
messages. After setting the overdrive filter the SENSIT sensor will only transmit a status
change event if the SENSIT sensor has been occupied of free for the set time.
15.2.1 CALIBRATION
Note
Setting or changing the
overdrive filter affects
reaction time.
Note
Default the overdrive filter is
set at 8 seconds.
Why calibrate?
The local earth magnetic field vector (value and direction) at an installed SENSIT sensor
depends on the orientation of the SENSIT sensor, the amount of metal in the neighborhood
and the location on the earth. When the calibration is done this local earth magnetic field
vector is stored. It is therefore necessary to always calibrate the sensors.
How can I see if the calibration is done correctly?
When connecting the Data Collector to the SIS, the SIS software will indicate calibration
errors for sensors which are not calibrated. In the Sensor data message there is a magnetic
un-calibrated bit which warns you if the SENSIT sensor thinks it is not calibrated well.
76/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
Does the parking need to be fully empty to calibrate the SENSIT sensors?
Yes, preferably the parking needs to be fully empty in order to calibrate the SENSIT sensors.
If you need to calibrate a single parking bay it is sufficient if only all neighboring bays are
empty. Easy calibration can be realized through the SIS website.
My parking lot is hardly ever empty, how can I calibrate the sensors?
If it is not possible to calibrate the entire parking lot, we suggest calibrating the parking lot
section by section directly after installation of the SENSIT’s.
15.3 OPTICAL SENSOR
What is the measuring interval of the optical sensor?
The optical sensors periodically checks once per second if there is a status change. (You can
extend battery life by setting slowing measuring intervals.)
Why is the SENSIT IR featured with two detection technologies?
Double detection technology provides a higher accuracy rate. Each detection technology
has its advantages and disadvantages. The combination of both ensures a reliable detection
product in all circumstances and differentiates our product from any other product in the
market. The optical sensor is potentially more accurate but sensitive for dirt, snow and ice.
We specify an average accuracy of 95% for the SENSIT Flush Mount (only magnet) and 98%
for the SENSIT IR (magnet and optical). In cases of snow or the optical sensor being covered
the unit will automatically switch to earth magnetic field detection.
Which sensor is making the decision; occupied or free?
In most cases the optical sensor is indicating the final status. The algorithm inside the
SENSIT sensor decides which type of sensor to trust. Of course you can ignore this and
decide for yourself which sensor to use, because the state of the magnetic and the optical
sensor is available.
What is the detection principal of the optical sensor?
The optical sensor is based on IR reflection. We are using a high power IR LED as transmitter
and a sensitive IR diode as receiver. The IR radiation is reflected by the bottom of a car or
truck and is received by the IR receiving diode. This means the bay is occupied.
Is the optical sensor influenced by snow or ice?
Yes the optical sensor detects based on something covering the sensor. In case the sensor is
covered with snow or frost it will be seen as occupied. In the sensor data message there is a
bit that warns you for possible ice on the SENSIT sensor. As the SENSIT IR is featured with
dual sensing technology you can also decide to switch the sensors to magnetic detection in
winter periods using the SIS software. Beside that on the SIS there is a global ice detection
algorithm implemented which automatically can decide to switch to the magnetic sensor in
case of ice or snow. See chapter 13.9.1 for more information.
Is the optical sensor influenced by dirt?
The optical sensor is designed to not easily be covered with little amounts of dust or sand
and therefore this will not affect the performance. Larger amounts of dirt will disable the
optical sensor. At an outdoor parking-lot, the self-cleaning surface of the SENSIT IR ensures
that dirt is automatically flushed of and does not easily attach to the SENSIT IR. This makes
it a very usable and practical system. The sites world-wide installed outdoors have since
installation (in about 2006) never been cleaned.
77/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
What happens in case of sandstorms, when the optical sensor is covered?
When the optical is covered with sand the sensor cannot detect reflections of a vehicle that
parks over the SENSIT sensor. So the optical sensor will indicate a free bay, the secondary
(magnetic) sensor will detect the movement of the different cars above the SENSIT sensor.
After a few (default: 10) mismatches between the continuous occupied optical sensor and
the magnetic sensor the final status will be indicated by the magnetic sensor. As soon as the
optical sensor is clean, the SENSIT sensor will automatically switch back to optical detection
again.
Is the SENSIT IR affected by direct sun light?
Normally the optical IR sensor is not affected by sunlight. Only at locations close to the
equator when the sun is directly above the SENSIT IR the optical sensor can give an
overexposure alert, which will indicate a free bay.
15.3.1 CALIBRATION
What is the maximum range of the optical sensor?
The IR reflection depends very much on the reflection coefficient of surface it radiates at.
Ceilings of over 3 meters (9 feet) are seen by the optical sensor. You can set the sensitivity
of the optical sensor when applying the sensors for indoor applications.
Can the optical sensor been used indoors?
The optical sensor can be used indoors, for this the IR transmitting power needs to be
adjusted (calibrated) to avoid the unit from detecting the ceiling.
15.4 MORE INFORMATION SENSIT AND MOUNTING
What filling material should I use?
The best way to fix the SENSIT sensors into the floor of the parking space is using rapid
mortar (eg.TM 5R). Ensure to fixate the SENSIT sensors during curing time, to avoid them
from floating in the mortar. When you want to use another brand of rapid mortal please
sent us the datasheet so we can analyze this and advise you on use.
Is a SENSIT IR snow plough resistant?
When using the SENSIT IR in environments with snowy weather conditions, we advise to set
a tolerance on the snow plough of 2 cm [0.78 in] to ensure the top of the sensor is not
damaged by the snow plough. The SENSIT IR is not fully snow plough resistant; however it
can withstand a few incidental hits. The SENSIT Flush Mount is snow plough resistant and
can be used in areas with frequent snow conditions, at the cost of a bit lower accuracy.
78/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
15.5 INSTALLATION
How much time does an installation take?
Based on installation experiences, an estimation of the needed man hours for installing
about 100 SENSIT IR is provided below.
Task
Description
Man hours
Preparation
Making a simple drawing of the parking
lot and upload it to the SIM
Installation
SENSIT IR
Determine location of every SENSIT IR,
drilling holes and fixing them
Installation Relay
Nodes
Mounting the Relay Nodes
Testing
Making a csv file, upload it to the SIS and
verify if all SENSIT sensors are online
How do I start?
Please read chapter 3 of this document for a 4-step installation plan.
15.6 BATTERY LIFE
What is the battery life?
The battery life of the SENSIT sensor in a good performing network is 5 years this with
default settings of the network and the measurement intervals.
Can batteries be exchanged?
The SENSIT sensors are fully sealed to ensure reliable operation in the outdoor environment
and to avoid any water leakage to the electronics. The batteries cannot be replaced, as this
would create water leakage and unreliable operation. The SENSIT sensor needs to be
replaced after end of battery life. The batteries of the Relay Node 2G can be replaced, see
chapter 7.7.
Note
A network uptime below 99%
will reduce the battery life
significantly.
Can I extend battery life of the SENSIT sensor by adjusting communication settings?
Yes you can extend battery life by adjusting the communication settings. Default the
SENSIT sensors are set to 16 timeslots. This communication setting will realize a battery life
time of 5 years and will achieve a good latency (fast and reliable communication network).
For applications where slower communication (more latency) is allowed 32 timeslots is
recommended to extend battery life time. Installations using over 15 Relay Nodes should
also be set to 32 time slots.
How can I change the communication settings to extend battery life?
Please consult Nedap how to change the communication settings if your application allows
slower communication or if your application needs more than 15 Relay Nodes.
How do we know if a SENSIT sensor runs out of batteries?
The battery voltages will be requested by the SENSIT Interface Server on a regular basis.
The SIS will display an icon in the node presence list in the SIS if the battery is low or almost
empty. See chapter 13.9.2 and chapter 13.9.3 for more information.
If I keep the product in stock for some time, do the batteries run down?
When shipped the units are in stock/transport mode to save battery life. That is why you
need to swipe the SENSIT sensors with a reset magnet to get them out of stock mode. In
stock/transport mode the SENSIT sensors hardly use any power. In this way you can have a
SENSIT sensor in stock for e.g. a year without influencing the final battery life.
79/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
15.7
RELAY NODES
What is a Relay Node?
A Relay node consists of a SENSIT configured in an active role and a Relay Node mounting
set. The mounting set allows for easy mounting of the Relay node onto a lamppost. The
Relay node is a normal SENSIT but configured differently, a Relay Node has a more active
role in the wireless network compared to a SENSIT. That is why we call a Relay Node an
active node and a SENSIT a passive node. The continuous transmitting and receiving of an
active node consumes more power than a passive node who is only listening to a few active
nodes to stay synchronized and to receive incoming messages. The battery life of the Relay
Node will be about 2 to 3 years. The advantage is that a Relay Node is still completely
wireless and does not require any power or communication cabling.
Note
Use of Relay nodes is
mandatory to ensure a fast
communicating, more stable
and a less energy consuming
SENSIT network.
What is a Relay Node 2G?
A Relay node 2G is a dedicated product for relaying message from the SENSIT sensors to
the Data Collector. The Relay Node 2G has an active role and in the Wireless SENSIT
Network. The battery lifetime of the Relay Node 2G is similar as the lifetime of the SENSIT
sensors. The Relay Node 2G is wireless and does not require any power or communication
cabling.
Why are Relay Nodes required?
Relay nodes are required to ensure a faster communication path to the Data Collectors, a
more robust network and less energy consumption. Relay Nodes are required to ensure that
SENSIT sensors positioned in the area can communicate directly via the Relay Node back to
the central system. If each SENSIT sensor would need to communicate via the other
SENSIT sensors installed in the floor, more communication ‘hops’ are needed. This will
cause a slower communicating network, with a higher chance of missing a message and
higher energy consumption.
How much Relay Nodes do I need to install?
The number of Relay Nodes depends on various parameters: number of SENSIT sensors,
distances and obstructions. A minimum of 1 Relay Nodes and 1 Data Collector is required
per installation to create a 2 path communication possibility for each SENSIT sensor. Nedap
can provide you with more detailed information on the amount of Relay Nodes per
installation for your site.
Has Nedap a tool to determine the number of needed Relay Nodes?
There is a tool available to make a better estimation of needed equipment, see chapter 4.
Please ask your Nedap account manager for more information.
What is the communication distance between Relay Nodes and other components of
the system?
Below the maximum recommended distances between the different nodes.
Data Collector
 Relay Node
Relay Node
 Relay Node
SENSIT
 Relay Node
Data Collector
 SENSIT
Data Collector
 Relay Node 2G omni-directional
Data Collector
 Relay Node 2G directional
Data Collector GPRS Relay Node 2G
Relay Node 2G
 Relay Node 2G
SENSIT
 Relay Node 2G omni-directional
SENSIT
 Relay Node 2G directional
25 m
50 m
25 m
25 m
35 m
50 m
10 m
100m
35 m
50 m
(82 ft)
(164 ft)
(82 ft)
(82 ft)
(135 ft)
(164 ft)
(33 ft)
(328 ft)
(135 ft)
(164 ft)
80/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
How do I replace a Relay Node?
After end of battery life, the SENSIT can easily be taken out of the Relay Node mounting
set. Only the SENSIT sensor configured as Relay Node would need to be replaced. The
batteries of a Relay Node 2G can be replaced, see chapter 7.7.
Can the Relay Nodes also be used for indoor car parks?
Yes, the Relay Nodes can also be used for indoor car parks, see also picture below. Indoor
car parks might require more Relay Nodes due to mounting height restrictions and influence
of concrete on communication.
15.8 DATA COLLECTOR
What is the Data Collector?
The Data Collect is the central unit which collects the events from SENSIT sensors via the
Relay nodes and transmits this information to the host system or SENSIT Interface
Software.
Can I implement data from the Data Collector directly?
No, this feature is not supported and subject to change. For easy integration we advise to
use the SENSIT Interface Software.
What is the most critical part of the SENSIT system?
The most critical part is the Data Collector when the power of the Data Collector is
interrupted or if the Data Collector is damaged the whole Wireless SENSIT Network will
stop working. Only with a good and powered Data Collector the wireless network will start.
By using an UPS, (short) power failure can be solved.
Where do I mount the Data Collector?
The Data Collector can be installed within 25 m [84 ft] from the first SENSIT node or Relay
Node. Be sure not to position the Data Collector in a metal enclosure as it will block the RF
communication. The Data Collector can be mounted in a plastic housing, which is
transparent for RF signals.
How can we make the Data Collector useable outdoors?
The standard Data collector can be placed in a plastic housing suitable for outdoor use. An
outdoor box which is made of a conduction material or contains a lot of conduction material
can create some problems as it blocks RF communication. A better solution is to use the
Data Collector GPRS it has IP65 housing.
What power wiring (cable specs) do I need for the standard Data Collector?
Power: 100-240 VAC, 50-60 Hz, 180mA,
Power input: 5 VDC, max 1A
Power consumption: 5VA
Communication between Data Collector and SIS: Ethernet Cat 5 E
81/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
Can the Data Collector GPRS be powered by a solar panel?
There are already several customers who autonomously power the
Data Collector GPRS with a solar panel. Also the Data Collector GPRS
at the Nedap test-site is powered by a solar panel (since December
2011).
The autonomous solar panel system at the Nedap test-site is a 30Wp
Solar panel, a charge regulator and two 22Ah /12V battery in parallel.
See picture at the right
The Data Collector GPRS will not consume more than 60mA at 12VDC on average.
How much data will a Data Collector GPRS use?
Normally the data usage will be below 250MB per month.
Can I replace the antenna for one that I can mount on top of a metal box and keep the
Data Collector inside this metal cabinet?
As for operational purposes this should not be an issue, on the condition that a suitable
antenna is applied. However ETSI and FCC does not allow change of the antenna, and
therefore as a manufacturer we cannot approve antenna change for this reason.
How often does the SENSIT sensor send an event to the Data Collector to alert a status
change?
The SENSIT sensor sends an event message immediately after a status change.
The baud-rate of the Data Collector is 115200 can I change it into another value?
The baud-rate of the Data Collector is fixed, you cannot change it.
Can I built the Data Collector into a pay & display machine?
Yes, when the pay & display machine is featured with Ethernet communication, this
communication could be applied. Keep into consideration that the RF antenna of the Data
Collector should be positioned behind RF transparent material (such as plastic) and not
incorporated in metal.
82/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
15.9 SENSIT INTERFACE SOFTWARE (SIS)
What is the SIS?
The SIS (SENSIT Interface Software) allows for easy configuration and filtering of event
messages received by the Data Collectors. The SIS enables configuration, installation, basic
administration and integration of the SENSIT system SIS functionality includes;

Easy integration via SOAP or REST

Easy remote support via web interface

DNNP (Dynamic Node Numbering Protocol)

Connection of multiple Data Collectors

Filtering of events

Easy event configuration

Easy management of the entire Wireless SENSIT Network

Automatic calibration

Debug and analyze tool

Automatic collection of missing messages

Configuration of parking bays

Stand-alone system with control of display per zone.

Graphics to indicate parking spaces and overstay
Why use a SIS?
Configuration and integration of the data from the SENSIT system becomes much easier.
The site can be accessed remotely allowing Nedap to give you better support on the
installation.
Can I control a display with the SIS?
Yes using a wireless display node built-into a display, the display can become part of the
Wireless SENSIT Network (WSN). You can set in the SIS software which parking zone the
display should control and indicate. See chapter 13.6.7 for more information. Using this
option a simple standalone application could be created with displays indicating available
spaces. No more than 2 wireless displays are allowed in the WSN to make sure the display
messages aren’t influencing the WSN too much.
83/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
How does the overstay sequence work?
The accuracy of detection is of critical importance when using the information for
enforcement applications. You want to avoid issuing unjustified tickets. In the table below
the whole overstay sequence and how to check an overstay is explained.
Event
SENSIT
Car parked
t1
Detected optical +
magnetic
Overdrive filter
(8s) passed.
t2
Event created and
transmitted, including;
sequence number, t2
Event at DC
t3
t4
No change
after 1 hour
t5
SIS
Event stored in database,
including; t2, t3 and t4.
SIS verifies sequence
number
Event (created at t2)
retransmitted
t6
Event already stored, so
ignored by SIS
Overstay time
elapsed
t7
Bay status changed into:
overstay, verify request
transmitted
Verify message
received
t8
Verify event
received
t9
Last event (created at
t2) is retransmitted
Bay status changed into:
verified overstay
Enforcement officer is notified and arrives at the bay, enforcer sends verification
request
SOAP request
received
t1
Verify message
received
t1
Verify event
received
t1
Verify request
transmitted
Last event (created at
t2) is retransmitted
Bay status answered via
the SOAP
Enforcer receives verification and can decide to issue a ticket after his final
observations.
How do we know when a SENSIT or Relay Node is working well?
With the node cross check menu on the SIS you can detect if all SENSIT sensors are still
communicating. Logged in as an advanced user it is possible to get a graphical overview of
the performance of the wireless SENSIT network. For more information, see chapter 13.8.5.
84/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
15.10 NETWORK & COMMUNICATION
How much events can a SENSIT node store?
Every SENSIT node is capable of storing 32 events in its internal memory.
What causes the latency of a SENSIT sensor?
The latency is built up out of different aspects;

The measurement interval;
The interval the SENSIT sensor verifies it status changed, default set at 1 second.

The overdrive filter;
The overdrive delay set in the SENSIT sensor is by default set at 8 seconds.

The number of hops;
The number of hops a message needs to arrive at the Data Collector, every hop
takes about 2 seconds.

Passive collisions;
In a busy car park multiple SENSIT sensors want to transmit their status change
message simultaneous, which might create passive collisions. In order to reduce
this we advise to ensure that each SENSIT sensor can at least communicate with 2
Relay Nodes offering multiple communication paths.
Example with default settings and without passive collisions:
The magnetic and optical sensor measures every second if the status of the bay is
changed. The overdrive filter waits 8 seconds before it transmits the event. In this
example the event is transmitted via 2 Relay Nodes; first from the SENSIT to the
nearest Relay Node and then from this Relay Node to the Relay Node close to the
Data Collector and finally from this Relay Node to the Data Collector. The total
(worst-case) time needed is:
Measurement + overdrive + SENSITRN + RNRN + RNData Collector =
1+8+2+2+2 = 15s
Example with default settings and with one passive collision:
The magnetic and optical sensor measures every second if the status of the bay is
changed. The overdrive filter waits 8 seconds before it transmits the event. In this
example the event is transmitted via 2 Relay Nodes; the sequence of transmitting
the messages is the same as in the example above but now a collision occurred in
the first transmission; another SENSIT transmitted an event at the same time to
the Relay Nodes. The total (worst-case) time needed is now:
Measurement + overdrive + collision + SENSITRN + RNRN + RNData
Collector = 1+8+10+2+2+2 = 25s
How many seconds does an event message take in general?
The transfer time is depending on the number of hops and if passive collisions take place. A
collision free transfer via one Relay Node takes less than 5 seconds, for every extra hop add
2 seconds. For a busy parking lot take into account at least 10 seconds extra for possible
passive collisions.
Is the package number always increasing per SENSIT?
Yes, the package number is automatically increased in sequence number per SENSIT and
the message is unique based on a combination of SENSIT ID number and package number.
How do we map the double words corresponding to "Sent time" and "event time" to
real dates?
The double word is the time in seconds from January 1st 1970 this is also used within UNIX
and therefore also known as 'Unix-time'.
85/92
SENSIT SYSTEM | MANUAL
Frequently Asked Questions
15.11 TECHNICAL MATTERS
What is the MTBF of the various components of the Wireless Space Count system?
In the table below the MTBF, MTTR and MTTF is given, so far this are estimated values.
MTBF
MTTR
without
spare
MTTR
with
spare
MTTF
SENSIT IR
63 years
7 days
1 hour
~40 years
SENSIT Flush Mount
63 years
7 days
1 hour
~40 years
SENSIT Surface Mount
76 years
7 days
1 hour
~40 years
Relay Node
65 years
7 days
1 hour
~40 years
Relay Node 2G
52 years
7 days
1 hour
~40 years
Data Collector
53 years
14 days
1 hour
~40 years
14 days
1 hour
~40 years
Data Collector GPRS
86/92
SENSIT SYSTEM | MANUAL
Appendix
16
APPENDIX
RAPID MORTAR
87/92
SENSIT SYSTEM | MANUAL
Appendix
MODIFIED SILICON POLYMER
Sabatack Fast
ultra-fastbonding
B.1
Description
Sabatack Fast is an ultra fast-acting 2-component, elastic, humidity-curing, MS polymerbased construction adhesive. Its primary use is bonding with fast hardening, handling after
only 2 hours, which makes this product excellent for use in mass production. Sabatack Fast
has a medium viscosity and a high modulus elasticity.
B.2
Field of application
Industrial and hand-made vehicle and coachwork construction, marine, ventilation and air
conditions, electro-technology, equipment assembly, metal and tin processing, plastics
technology, civil & environmental engineering and building & construction. For the elastic
bonding of frames, profiles, plates etc. Also for sealing seams, overlaps, joints and cracks.
Suitable for interior and exterior use. Excellent for use in mass production.
B.3







Advantages
fast and controlled curing, high end strength
adhesion without primer, fast drying
can be painted wet-on-wet, hardly any shrinkage
no blistering, almost odorless
free from solvents, isocyanates and silicones
UV-stable, high temperature resistance
certificates: Wheelmark (164.106/1121/WCL MED0326), ISEGA (in connection with
HACCP)
B.4
Method of use
For instructions for use, repaint ability and pre-treatment, see the relevant info sheets at
www.saba.nl
B.5
TECHNICAL DATA
Order information
Other packaging and colours on request. The shelf life may vary for large packaging.
Safety recommendations
For more information about safety, see the relevant SABA safety data sheet.
Component A Component B
Basis
MS polymer, humidity-curing MS polymer, humidity-curing
Density
(EN 542) approx. 1.380 kg/m3 approx. 1.144 kg/m3
Solids content
approx. 100% approx. 85%
Open time
(23 °C, 50% RLV) approx. 10 minutes
Tack free
(23 °C, 50% RLV) completely after approx. 12 hours
Cure rate
(23 °C, 50% RLV) even after 48 hours
Hardness Shore A
(EN ISO 868) approx. 55
Volume alteration
(EN ISO 10563) < 5%
Modulus at 100%
(ISO 37/DIN 53504) approx. 1.5 N/mm2
Tensile strength
(ISO 37/DIN 53504) approx. 2.6 N/mm2
88/92
SENSIT SYSTEM | MANUAL
Appendix
Elongation at break
Shear strength
Working temperature
Storage temperature
Temperature resistance
Short temperature resistance
Packaging
Contents
Color
Article No.
Shelf life
(ISO 37/DIN 53504) approx. 330%
(ISO 4587) approx. 1.7 N/mm2
min. +5 °C to max. +35 °C
min. +5 °C to max. +25 °C
min. -40 °C to max. +120 °C
max. +180 °C (30 minutes)
dual-cartridge
490 ml (contains 7 items)
White (RAL 9003) black (RAL 9011)
100201 DJW 100862 DJW
9 months (in unopened packaging)
89/92
SENSIT SYSTEM | MANUAL
Appendix
POLYURETHAN
P E R M A P U R® 2 6 5 4 A / B
Universal Polyurethane liquid adhesive
PERMAPUR® 2654 A/B consists of two components A-component (Polyol) and a Bcomponent (Isocyanate). The resin is supplied in a bi-pack. PERMAPUR 2654 A/B is used as
an universal polyurethane resin which can be applied by pouring the fluid. The system is
insensitive to moist and shows no blistering and is therefore less critical in processing.
Technical details
Color:
Color mix:
Processing time:
Gel time:
Curing time:
Viscosity:
Hardness:
Specific gravity:
Specific resistance:
Breakdown voltage:
Max. Temperature:
Water absorption:
Storage:
A-component black fluid
B component dark brown fluid
Black
10 min / 20°C
15 min / 20°C
24 h /20°C
4.500 mPa.sec/20°C
45° Shore D
1,5 g/cm3
1 x 1014 W.cm
20 KV/mm
-25°C tot +120°C
<1%
At room temperature (20 ° C) in tightly closed Verpa
Branching 12 months
90/92
SENSIT SYSTEM | MANUAL
Appendix
DISCLAIMER
This information is furnished for guidance, and with no guarantee as to its accuracy or
completeness; its publication conveys no license under any patent or other right, nor does
the publisher assume liability for any consequence of its use; specifications and availability
of goods mentioned in it are subject to change without notice; it is not to be reproduced in
any way, in whole or in part, without the written consent of the publisher.
91/92
SENSIT SYSTEM | MANUAL
Appendix
DOCUMENT REVISION
Version
Date
Comment
1.3.3
24-02-2014
Start documents and new corporate style
1.4
14-04-2014
Adjustments for 1.4 release.
1.4.1
12-05-2014
Adjustments for release 1.4.1, RelayNodeTool added,
Document renamed.
1.4.2
15-07-2014
Adjustments for release 1.4.2, FCC & IC Declaration and some
small textual improvements.
1.4.3
27-10-2014
Adjustments for release 1.4.3, some small textual
improvements.
1.5.0
17-12-2014
Adjustments for release 1.5.0; Parking enforcement screens.
1.5.1
17-12-2014
Adjustments for release 1.5.1; DNNP
1.5.2
04-03-2015
Adjustments for release 1.5.2; EPL
92/92

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 92
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Report
Author                          : Gerjo Tannemaat
Subject                         : Report
Keywords                        : report, template, sjabloon
Creator                         : Microsoft® Word 2013
Create Date                     : 2015:03:04 14:55:40+01:00
Modify Date                     : 2015:03:04 14:55:40+01:00
Producer                        : Microsoft® Word 2013
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGDSENSITEPL

Navigation menu