Nedap N V SENSNODE Sensor for the Wireless Space Count system for parking lots User Manual SENSIT IR

N. V. Nederlandsche Apparatenfabriek NEDAP Sensor for the Wireless Space Count system for parking lots SENSIT IR

Contents

User manual SENSIT IR

2009-11-23    This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of  goods  mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 1 of 10  Wireless Space Count  Manual SENSIT IR
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 2 of 10   CONTENTS 1 INTRODUCTION..............................................................................................................................3 1.1 SENSIT IR.................................................................................................................. 3 2 INSTALLATION SENSIT IR .............................................................................................................4 2.1 SAFETY PRECAUTIONS........................................................................................... 4 2.2 DIMENSIONS............................................................................................................. 4 2.3 REPLACEMENT ........................................................................................................ 4 2.4 MOUNTING PROCEDURE SENSIT IR ...................................................................... 5 3 PROJECT SUPPORT ......................................................................................................................7 3.1 SITE SURVEY & INSTALLATION ADVICE................................................................ 7 3.2 ON-SITE CERTIFICATION......................................................................................... 7 4 FCC AND IC DECLARATION...........................................................................................................8 4.1 Compliance statements (part15.19) ........................................................................... 8 4.2 Warning (part15.21)................................................................................................... 8 4.3 RF Exposure (OET Bulletin 65).................................................................................. 8 4.4 Information to the User (Part 15.106(b)) .................................................................... 8 5 TECHNICAL SPECIFICATIONS.......................................................................................................9 A PART NUMBERS...........................................................................................................................10
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 3 of 10   1  INTRODUCTION  The Wireless Space Count system facilitates accurate measurement on occupancy of individual parking spaces in car parks, and on-street parking spaces. This information can be used to guide traffic to free parking spaces but can also be used for on-street parking enforcement and overstay detection. For on-street  enforcement  the  number  of  occupied  parking  spaces  can  be  compared  with  the  number  of payments realized by the pay station. For overstay detection the system alerts instantly a parking officer to  the  presence  of  nearby  overstaying  vehicles.  Based  on  this  information  you  can  exactly  determine which space to enforce.  1.1  SENSIT IR The  SENSIT  IR  is  mounted  into  the  floor  of  each  parking  space.  The  SENSIT  IR  is  suitable  for  floor mounting  as  well  outdoor  as  indoor.  The  SENSIT  IR  are  featured  with  detection  and  communicate wireless  with  each  other,  creating  their  own  network.  The  SENSIT  IR  do  not  require  power  wiring,  in contrast  to  conventional  systems  that  require  wiring  throughout  the  car  park  and  mounting  onto  the ceiling.
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 4 of 10   2  INSTALLATION SENSIT IR  2.1  SAFETY PRECAUTIONS The following safety precautions should be observed during normal use, service and repair. •  The SENSIT IR may only be installed and serviced by qualified service personnel. •  To be sure of safety,  do not modify or add anything to the SENSIT IR other than mentioned in this manual or indicated by NEDAP N.V.  2.2  DIMENSIONS The  SENSIT  IR  is  designed  for  mounting  into  the  floor  of  a  parking  space.  See  Figure  1  for  the dimensions of the unit in mm.  The bottom of the SENSIT IR is laser engraved with the node ID number, see Figure 2.  Figure 1: Dimensions SENSIT IR   Figure 2: Top and bottom laser engraved side of the SENSIT IR  The node ID is mentioned on the bottom of the housing under ID. There is also a 125kHz passive RFID label embedded into the SENSIT IR. This can be used for verification of the SENSIT IR or to localize the SENSIT IR on the parking lot. 2.3  REPLACEMENT When  the  battery  life  of  the  SENSIT  IR  fails  after  specified  life  time,  we  advise  to  replace  the  unit completely.  The SENSIT IR is fully sealed and for outdoor use therefore batteries cannot be replaced.  Drill out the old SENSIT IR and complete the mounting procedure as describe in the next paragraph.
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 5 of 10   2.4  MOUNTING PROCEDURE SENSIT IR  Below the mounting procedure for the SENSIT IR.   Step   1:    Distribute  the  SENSIT  IR  over  the  empty parking lot (without  mounting them into  the floor).  Step 2:  All  SENSIT IR  are  set  to  transport/stock mode  during  shipment.  Prior to  installation  all SENSIT IR must be swept with a strong magnet.  This will  give the SENSIT IR a reset. Please ensure to use a strong magnet (Neodymium).  Note:  Once out of the transport/stock mode the battery lifetime starts to count.   Step 3:  Write down the node ID number on your installation plan so you are sure which SENSIT IR is positioned in which parking bay.  Step 4:  Verify if all the SENSIT IR are online and if communication is received by the SENSIT DATACOLLECTOR after the magnet sweep. Do this prior to mounting the units into the ground.  Note:  Only once all SENSIT IR are live and seen in the software they can be installed into the pavement.  Step 5:  Drill a hole of 85 mm (3.35 in) into the centre of the parking bay.   Figure 3: SENSIT IR installation  Step 6:  Use the right amount of filler    Figure 4: SENSIT IR installation Step  7:  Double-check  the  node  ID  number and  the  parking  bay  on  the installation  plan  and  place  the SENSIT IR into the hole
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 6 of 10  Figure 5: SENSIT IR installation Step 8:  After installation the SENSIT IR must be calibrated with no car on top of the sensor or on neighbouring parking bays.  Note:  When the SENSIT IR are not calibrated they hardly send any messages. This is due  to  the  fact  that  there  are  no  events  generated  because  the  magnetic tressholds are not crossed.     Figure 6: Finished SENSIT IR installation
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 7 of 10   3  PROJECT SUPPORT  Based  on our thorough project  analysis including configuration and installation advice we can offer  the customer the best AVI solution.   3.1  SITE SURVEY & INSTALLATION ADVICE  This will consist of an engineer visiting the site to visually inspect and analyze the location. We will then carry out calculations and provide you with detailed configuration and installation advice for the Wireless Space Count equipment for a specific project.   3.2  ON-SITE CERTIFICATION  An engineer will visit the site to inspect the installation of the equipment on reliable and accurate detection. Nedap engineers are not involved in installation (wiring) of any equipment. The installation must be completed before the engineer arrives on-site. We will ensure that the operation confirms our commissioning requirements, only on condition of prior given installation advice.
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 8 of 10   4  FCC AND IC DECLARATION  4.1  Compliance statements (part15.19)  This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.  Operating is subject to the following two conditions:  (1) This device may not cause harmful interference, and  (2) This device must accept any interference received, including interference that may cause undesired operation.   4.2  Warning (part15.21)  Changes or modifications not expressly approved by party responsible for compliance could void the user’s authority to operate the equipment.   4.3  RF Exposure (OET Bulletin 65)  To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20cm separation distance between the antenna and all persons.   4.4  Information to the User (Part 15.106(b))  Note: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which can be determine by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  - Reorient or relocate some node  - Consult the dealer or an experienced radio/TV technician for help.
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 9 of 10   5  TECHNICAL SPECIFICATIONS SENSIT IR (EU)  9898344 Operating frequency  868.2 MHz   CE compliant EN 60950-1 EN50357 and EN 50364 EN  301  4889-1  V1.6.1  and  EN  301  489-3 V1.4.1 EN 61000-6.1, EN 61000-6-2 and 61000-6-3 EN 55011 Class B EN 61204-3  EN 300-220-1 ERV REC 70-03  Dimensions  Ø 80 mm  (3.15 inch) and 70 mm (2.8 inch)   Weight  365 g  (12.87oz)   Protection   IP67, completely sealed housing   Material   Black/Yellow Polyethylene   Operational temperature  -20°C … +85°C     (-4°F … +185°F)   Storage temperature  -20°C … +85°C                 (-4°F … +185°F)   Communication range  From sensor to sensor >10m          (33 feet)   Dependent on the environment Power supply  Built-in lithium battery   Expected battery life 5 years Mounting  Into the floor of a parking space   Detection  Magnetic and optic   Detection  height  90 cm   (35.5 inch)    SENSIT IR (US and Canada)  9898620 Operating frequency  902-928 MHz (FHSS)    FCCID: CGDSENSDATA IC: 1444A-SENSDATA    Dimensions  Ø 80 mm  (3.15 inch) and 70 mm (2.8 inch)   Weight  365 g  (12.87oz)  Protection  IP67, completely sealed housing   Material  Black/Yellow Polyethylene   Operational temperature  -20°C … +85°C     (-4°F … +185°F)  Storage temperature  -20°C … +85°C                 (-4°F … +185°F)  Communication range  From sensor to sensor >10m        (33 feet)  Dependent on the environment Power supply  Built-in lithium battery   Expected battery life 5 years Mounting  Into the floor of a parking space   Detection  Magnetic and optic   Detection  height  90 cm   (35.5 inch)
  Wireless Space Count: SENSIT IR  © Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO  Page 10 of 10     A  PART NUMBERS  SENSIT IR  SENSIT IR (EU)  part number:   9898344  SENSIT IR (US)  part number:   9898620            For full product information visit www.nedapavi.com