Nedap N V SENSNODE Sensor for the Wireless Space Count system for parking lots User Manual SENSIT IR

N. V. Nederlandsche Apparatenfabriek NEDAP Sensor for the Wireless Space Count system for parking lots SENSIT IR

Contents

User manual SENSIT IR

Download: Nedap N V SENSNODE Sensor for the Wireless Space Count system for parking lots User Manual SENSIT IR
Mirror Download [FCC.gov]Nedap N V SENSNODE Sensor for the Wireless Space Count system for parking lots User Manual SENSIT IR
Document ID1234673
Application IDBsDSsdwmVZ6TN+5Ba4RxjQ==
Document DescriptionUser manual SENSIT IR
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize122.51kB (1531350 bits)
Date Submitted2010-01-29 00:00:00
Date Available2010-01-31 00:00:00
Creation Date2009-11-23 09:08:32
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2009-11-23 09:08:32
Document TitleMicrosoft Word - Wireless Space Count Manual SENSIT IR v1.3.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: g.tannemaat

Wireless Space
Count
Manual SENSIT IR
2009-11-23
This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication
conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of
its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be
reproduced in any way, in whole or in part, without the written consent of the publisher.
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 1 of 10
Wireless Space Count: SENSIT IR
CONTENTS
INTRODUCTION..............................................................................................................................3
1.1
INSTALLATION SENSIT IR .............................................................................................................4
2.1
2.2
2.3
2.4
SAFETY PRECAUTIONS........................................................................................... 4
DIMENSIONS............................................................................................................. 4
REPLACEMENT ........................................................................................................ 4
MOUNTING PROCEDURE SENSIT IR ...................................................................... 5
PROJECT SUPPORT ......................................................................................................................7
3.1
3.2
SENSIT IR.................................................................................................................. 3
SITE SURVEY & INSTALLATION ADVICE................................................................ 7
ON-SITE CERTIFICATION......................................................................................... 7
FCC AND IC DECLARATION...........................................................................................................8
4.1
4.2
4.3
4.4
Compliance statements (part15.19) ........................................................................... 8
Warning (part15.21) ................................................................................................... 8
RF Exposure (OET Bulletin 65).................................................................................. 8
Information to the User (Part 15.106(b)) .................................................................... 8
TECHNICAL SPECIFICATIONS.......................................................................................................9
PART NUMBERS...........................................................................................................................10
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 2 of 10
Wireless Space Count: SENSIT IR
INTRODUCTION
The Wireless Space Count system facilitates accurate measurement on occupancy of individual parking
spaces in car parks, and on-street parking spaces. This information can be used to guide traffic to free
parking spaces but can also be used for on-street parking enforcement and overstay detection. For onstreet enforcement the number of occupied parking spaces can be compared with the number of
payments realized by the pay station. For overstay detection the system alerts instantly a parking officer
to the presence of nearby overstaying vehicles. Based on this information you can exactly determine
which space to enforce.
1.1 SENSIT IR
The SENSIT IR is mounted into the floor of each parking space. The SENSIT IR is suitable for floor
mounting as well outdoor as indoor. The SENSIT IR are featured with detection and communicate
wireless with each other, creating their own network. The SENSIT IR do not require power wiring, in
contrast to conventional systems that require wiring throughout the car park and mounting onto the
ceiling.
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 3 of 10
Wireless Space Count: SENSIT IR
INSTALLATION SENSIT IR
2.1 SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and repair.
• The SENSIT IR may only be installed and serviced by qualified service personnel.
•
To be sure of safety, do not modify or add anything to the SENSIT
manual or indicated by NEDAP N.V.
IR
other than mentioned in this
2.2 DIMENSIONS
The SENSIT IR is designed for mounting into the floor of a parking space. See Figure 1 for the
dimensions of the unit in mm. The bottom of the SENSIT IR is laser engraved with the node ID number,
see Figure 2.
Figure 1: Dimensions SENSIT IR
Figure 2: Top and bottom laser engraved side of the SENSIT IR
The node ID is mentioned on the bottom of the housing under ID. There is also a 125kHz passive RFID
label embedded into the SENSIT IR. This can be used for verification of the SENSIT IR or to localize the
SENSIT IR on the parking lot.
2.3 REPLACEMENT
When the battery life of the SENSIT IR fails after specified life time, we advise to replace the unit
completely. The SENSIT IR is fully sealed and for outdoor use therefore batteries cannot be replaced.
Drill out the old SENSIT
IR
and complete the mounting procedure as describe in the next paragraph.
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 4 of 10
Wireless Space Count: SENSIT IR
2.4 MOUNTING PROCEDURE SENSIT IR
Below the mounting procedure for the SENSIT
Step 1: Distribute the SENSIT
floor).
IR
IR.
over the empty parking lot (without mounting them into the
Step 2: All SENSIT IR are set to transport/stock mode during shipment. Prior to installation all
SENSIT IR must be swept with a strong magnet. This will give the SENSIT IR a reset.
Please ensure to use a strong magnet (Neodymium).
Note:
Once out of the transport/stock mode the battery lifetime starts to count.
Step 3: Write down the node ID number on your installation plan so you are sure which SENSIT
IR is positioned in which parking bay.
Step 4: Verify if all the SENSIT IR are online and if communication is received by the SENSIT
DATACOLLECTOR after the magnet sweep. Do this prior to mounting the units into the
ground.
Note:
Only once all SENSIT
into the pavement.
IR
are live and seen in the software they can be installed
Step 5: Drill a hole of 85 mm (3.35 in) into the
centre of the parking bay.
Figure 3: SENSIT
IR
installation
Figure 4: SENSIT
IR
installation
Step 6: Use the right amount of filler
Step 7: Double-check the node ID number
and the parking bay on the
installation plan and place the
SENSIT IR into the hole
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 5 of 10
Wireless Space Count: SENSIT IR
Step 8: After installation the SENSIT
neighbouring parking bays.
Note:
IR
Figure 5: SENSIT IR installation
must be calibrated with no car on top of the sensor or on
When the SENSIT IR are not calibrated they hardly send any messages. This is
due to the fact that there are no events generated because the magnetic
tressholds are not crossed.
Figure 6: Finished SENSIT
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
IR
installation
Page 6 of 10
Wireless Space Count: SENSIT IR
PROJECT SUPPORT
Based on our thorough project analysis including configuration and installation advice we can offer the
customer the best AVI solution.
3.1 SITE SURVEY & INSTALLATION ADVICE
This will consist of an engineer visiting the site to visually inspect and analyze the location. We will then
carry out calculations and provide you with detailed configuration and installation advice for the Wireless
Space Count equipment for a specific project.
3.2 ON-SITE CERTIFICATION
An engineer will visit the site to inspect the installation of the equipment on reliable and accurate
detection. Nedap engineers are not involved in installation (wiring) of any equipment. The installation
must be completed before the engineer arrives on-site. We will ensure that the operation confirms our
commissioning requirements, only on condition of prior given installation advice.
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 7 of 10
Wireless Space Count: SENSIT IR
FCC AND IC DECLARATION
4.1 Compliance statements (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operating is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
4.2 Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could void the
user’s authority to operate the equipment.
4.3 RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should
only be used or installed at locations where there is at least 20cm separation distance between the
antenna and all persons.
4.4 Information to the User (Part 15.106(b))
Note: This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates uses and can radiate radio
frequent energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does not cause harmful interference to radio or television reception, which can be determine
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate some node
- Consult the dealer or an experienced radio/TV technician for help.
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 8 of 10
Wireless Space Count: SENSIT IR
TECHNICAL SPECIFICATIONS
SENSIT IR (EU)
9898344
Operating frequency
868.2 MHz
CE compliant
EN 60950-1
EN50357 and EN 50364
EN 301 4889-1 V1.6.1 and EN 301 489-3
V1.4.1
EN 61000-6.1, EN 61000-6-2 and 61000-6-3
EN 55011 Class B
EN 61204-3
EN 300-220-1
ERV REC 70-03
Dimensions
Ø 80 mm (3.15 inch) and 70 mm (2.8 inch)
Weight
365 g
Protection
IP67, completely sealed housing
Material
Black/Yellow Polyethylene
Operational temperature
-20°C … +85°C
(-4°F … +185°F)
Storage temperature
-20°C … +85°C
(-4°F … +185°F)
Communication range
From sensor to sensor >10m
Power supply
Built-in lithium battery
Mounting
Into the floor of a parking space
Detection
Magnetic and optic
Detection height
90 cm
(12.87oz)
(33 feet)
Expected battery life 5 years
(35.5 inch)
SENSIT IR (US and Canada)
Operating frequency
Dependent on the environment
9898620
902-928 MHz (FHSS)
FCCID: CGDSENSDATA
IC: 1444A-SENSDATA
Dimensions
Ø 80 mm (3.15 inch) and 70 mm (2.8
inch)
Weight
365 g
Protection
IP67, completely sealed housing
Material
Black/Yellow Polyethylene
Operational temperature
-20°C … +85°C
(-4°F … +185°F)
Storage temperature
-20°C … +85°C
(-4°F … +185°F)
Communication range
From sensor to sensor >10m
Power supply
Built-in lithium battery
Mounting
Into the floor of a parking space
Detection
Magnetic and optic
Detection height
90 cm
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
(12.87oz)
(33 feet)
Dependent on the environment
Expected battery life 5 years
(35.5 inch)
Page 9 of 10
Wireless Space Count: SENSIT IR
PART NUMBERS
SENSIT
IR
SENSIT
IR
(EU)
part number:
9898344
SENSIT
IR
(US)
part number:
9898620
For full product information visit www.nedapavi.com
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 10 of 10

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 10
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2009:11:23 09:08:32
Modify Date                     : 2009:11:23 09:08:32
Title                           : Microsoft Word - Wireless Space Count Manual SENSIT IR v1.3.doc
Creator                         : PScript5.dll Version 5.2.2
Author                          : g.tannemaat
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGDSENSNODE

Navigation menu