Nedap N V T325RRF ASSY T325R RF User Manual Manual
N. V. Nederlandsche Apparatenfabriek NEDAP ASSY T325R RF Manual
Manual
ASSY T325R RF IR 4x | insullation ring 1x | ASSY T325R RF 2x | filter 2x | connector RJ45 Warning This equipment should be installed, operated, serviced, and repaired by qualified personnel only. The installation and interconnection of this equipment to facility wiring and other equipment must be done by a competent, qualified craftsperson who is familiar with applicable standards and codes governing the installation. Installation methods, practices, or procedures that are unauthorised or done improperly are dangerous and could result in serious personal injury or damage to property and equipment. 20mm 0.79in 325mm 1'0.80" dimensions 277,5mm 10.93in 231.7mm 9.12in 1534.3mm 5'0.41" 1378.3mm 4'6.26" (Customer counter) 60mm 2.36in Mounting holes Use M10-studs 322mm 1'0.68" 328.6mm 1'0.94" 97.7mm 3.85in conduit or slit (topview) Quick reference : ASSY T325R RF IR N.V. Nederlandsche Apparatenfabriek “Nedap” dsgn : CvdB Parallelweg 2, NL-7141 DC Groenlo (The Netherlands) date : 15 September 2017 10:41 AM Mail: support-retail@nedap.com item : 9565795 Copyright © by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed document : T9565795-45.01 in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. revision : A.02 drill the hole Øø 13 mm/(Ø 0.5in) 13mm ø 0.5” Drill the hole Clean the hole Insert Hilti-hit Place the nut always use a nylon insulation ring 22 Nut M10 (not included in installation set) Retainer ring M10 (not included in installation set) Nylon insulation ring M10 (included in installation set) remove covers 9090mm mm (3.5in) / 3.5” Screw M3x10 place near to a wallsocket (RF) distance to the wall (RF) >>20 (7.9in) 20cm cm (7.9 in.) distance to a normal door or sliding door (RF) > 40 cm (15.8in) > 40 cm (15.8 in.) distance to roller shutter (RF) > 70 (27.6in) > 70cm cm (27.6 in.) cabling Rx Tx Instal orient lation ation: Stor Sale e exit (E s fl AS) Stoc oor (SRSF kroo m (G ) R) Ethernet cable Renos side IN p revio Sale Stoc floor (EA kr Load oom (S S) RSF ing b ay (G ) R) OUT next filters Filter Renos network IN Renos network OUT P.I. > network OUT power system Plug the Power Inserter into the socket. 230V 115V INPORTANT: Network should be connected in the “network setup”-step of the installation wizard. Do not connect a network to !Sense before power up! connecting a laptop to the Renos unit Renos - Service port Attach your laptop to one of the Renos units with a mini USB-USB cable. Open the browser on your laptop and go to: http://192.168.133.1 Configure the system using the installation wizard. NOTE: Start up takes approximately 3 minutes. place keyswitch (optional) Remove cover Push to remove small metal part Place keyswitch (can be placed on both sides of the antenna) place covers Screw M3x10 label information Pull to see the label information (Two labels at the front side and one at the back side) network setup When on the “network setup” -step of the installation wizard, determine the position of the network and decide how to connect to the !Sense network. Network to Power Inserter IN Network to last Renos OUT Network to USB-Network adapter (in any gate) Renos 50Ω Connect to the 50Ω PCB from the antenna. Lights / IR Connect to the lights and customer counting. Add-on Provide power and synchronisation to add-ons, like the RFID reader. Network IN Connected to the Network OUT of a previous Renos unit or a Power Inserter. USB Connect accessories to Renos, like the RFID reader or USB network adapter. Network OUT Connected to the Network IN of a previous Renos unit or a Power Inserter. Can also be left unconnected or connected to the customer network. Mini USB service port Connect your laptop to configure the Renos system. RS485 connector Connect to the smart deactivator(s). Buzzer connector Connect to the buzzer. Caution: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. status LEDs Renos Green On There is a Renos unit connected to the OUT port of this unit Off There is no Renos unit connected to the OUT port of this unit Blinking There is no device connected to the OUT port of this unit On There is a Power Inserter connected to the OUT port of this unit On There is an issue with the power supply at the OUT port of this unit (too little current drawn) Blinking There is an issue with the power supply at the OUT port of this unit (too much current drawn) Off There is no issue with the power supply at the OUT port of this unit Blinking The operating system on the Renos unit is running Off The operating system on the Renos unit is not running Blinking The storage flash on the Renos unit is accessed Off The storage flash on the Renos unit is not accessed On The firmware on the Renos unit is running Off The firmware on the Renos unit is not (yet) running Blue Red Yellow Green Green Disclaimer Nedap intends to make this manual accurate and complete. However, Nedap does not warrant that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. Nedap disclaims any liability for damage to property or personal injury resulting, in whole or in part, from improper installation, modification, use or misuse of its products. The information contained in this document is subject to change without notice. FCC and IC Compliance statement This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Cet appareil se conforme aux normes CNR 210 exemptés de license du Industry Canada. L’opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune interférence, et (2) cet appareil doit accepter n’importe quelle interférence, y inclus interférence qui peut causer une opération non pas voulu de cet appareil. Les changements ou modifications n’ayant pas été expressément approuvés par la partie responsable de la conformité peuvent faire perdre à l’utilisateur l’autorisation de faire fonctionner le matériel. FCC and IC Radiation Exposure Statement This equipment complies with FCC and Canadian radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 5 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet équipement est conforme a CNR-102 limites énoncées pour un environne- ment non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 5 cm entre le radiateur et votre corps. This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numérique de Classe B est conforme à la norme Canadienne ICES-003. FCC Information to the user Note: This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which can be determine by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver. NOTE: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. To ensure compliance with FCC regulations, use only the shielded interface cables provided with the product, or additional specified components or accessories that can be used with the installation of the product. Declaration of Conformity Hereby, De N.V. Nederlandsche Apparatenfabriek “Nedap” declares that the radio equipment type ASSY T325R RF is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://portal.nedapretail.com/ User manual The complete instruction manual can be found at https://portal.nedapretail.com/
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01 Create Date : 2017:09:15 10:42:56+02:00 Metadata Date : 2017:09:15 10:43:04+02:00 Modify Date : 2017:09:15 10:43:04+02:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:7e20100b-7c52-4114-8b69-893ea61b0f7c Original Document ID : xmp.did:FD7F1174072068119457DD866944A140 Document ID : xmp.id:aa4c6c4d-8acb-6a43-a4ab-e33b42d35cbc Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:ebfa2cb3-69e0-7d4c-b01c-18e7e8b681af Derived From Document ID : xmp.did:6A305B24E303E211A740EE653DA3658D Derived From Original Document ID: xmp.did:FD7F1174072068119457DD866944A140 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:09:15 10:42:57+02:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 8 Creator : Adobe InDesign CC 2017 (Windows)EXIF Metadata provided by EXIF.tools