Nedap N V T325RRFMD ASSY T325R RF+MD User Manual Manual

N. V. Nederlandsche Apparatenfabriek NEDAP ASSY T325R RF+MD Manual

Manual

Download: Nedap N V T325RRFMD ASSY T325R RF+MD User Manual Manual
Mirror Download [FCC.gov]Nedap N V T325RRFMD ASSY T325R RF+MD User Manual Manual
Document ID3589286
Application ID3RuPzg9fNSyerURomBzLHg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize165.92kB (2074005 bits)
Date Submitted2017-10-01 00:00:00
Date Available2017-10-04 00:00:00
Creation Date2017-09-15 10:42:56
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-09-15 10:43:04
Document TitleManual
Document CreatorAdobe InDesign CC 2017 (Windows)

ASSY T325R RF IR
4x | insullation ring
1x | ASSY T325R RF
2x | filter
2x | connector RJ45
Warning
This equipment should be installed, operated, serviced, and repaired by qualified personnel only. The installation and interconnection of this equipment to facility wiring and other
equipment must be done by a competent, qualified craftsperson who is familiar with applicable standards and codes governing the installation. Installation methods, practices, or
procedures that are unauthorised or done improperly are dangerous and could result in serious personal injury or damage to property and equipment.
20mm 0.79in
325mm 1'0.80"
dimensions
277,5mm 10.93in
231.7mm 9.12in
1534.3mm 5'0.41"
1378.3mm 4'6.26" (Customer counter)
60mm 2.36in
Mounting holes
Use M10-studs
322mm 1'0.68"
328.6mm 1'0.94"
97.7mm 3.85in
conduit or slit
(topview)
Quick reference : ASSY T325R RF IR
N.V. Nederlandsche Apparatenfabriek “Nedap”
dsgn
: CvdB
Parallelweg 2, NL-7141 DC Groenlo (The Netherlands)
date
: 15 September 2017 10:41 AM
Mail: support-retail@nedap.com
item
: 9565795
Copyright © by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed
document : T9565795-45.01
in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP.
revision
: A.02
drill the hole
Øø 13
mm/(Ø
0.5in)
13mm
ø 0.5”
Drill the hole
Clean the hole
Insert Hilti-hit
Place the nut
always use a nylon insulation ring
22
Nut M10			
(not included in installation set)
Retainer ring M10		
(not included in installation set)
Nylon insulation ring M10
(included in installation set)
remove covers
9090mm
mm (3.5in)
/ 3.5”
Screw M3x10
place near to a wallsocket (RF)
distance to the wall (RF)
>>20
(7.9in)
20cm
cm (7.9
in.)
distance to a normal door or sliding door (RF)
> 40
cm (15.8in)
> 40 cm (15.8 in.)
distance to roller shutter (RF)
> 70
(27.6in)
> 70cm
cm (27.6
in.)
cabling
Rx
Tx
Instal
orient lation
ation:
Stor
Sale e exit (E
s fl
AS)
Stoc oor (SRSF 
kroo
m (G ) 
R) 
Ethernet cable
Renos side


IN p
revio



Sale
Stoc floor (EA
kr
Load oom (S S)
RSF
ing b
ay (G )
R)
OUT
next
filters
Filter
Renos network IN
Renos network OUT
P.I. > network OUT
power system
Plug the Power Inserter into the socket.
230V
115V
INPORTANT:
Network should be connected in the “network setup”-step of the installation wizard.
Do not connect a network to !Sense before power up!
connecting a laptop to the Renos unit
Renos - Service port
Attach your laptop to one of the Renos units with a mini USB-USB cable.
Open the browser on your laptop and go to:
http://192.168.133.1
Configure the system using the installation wizard.
NOTE:
Start up takes
approximately 3 minutes.
place keyswitch
(optional)
Remove cover
Push to remove small metal part
Place keyswitch (can be placed on both sides of the antenna)
place covers
Screw M3x10
label information
Pull to see the label information (Two labels at the front side and one at the back side)
network setup
When on the “network setup” -step of the installation wizard,
determine the position of the network and decide how to connect to the !Sense network.
Network to Power Inserter IN
Network to last Renos OUT
Network to USB-Network adapter (in any gate)
Renos
50Ω			
Connect to the 50Ω PCB from the antenna.
Lights / IR			
Connect to the lights and customer counting.
Add-on			
Provide power and synchronisation to add-ons, like the RFID reader.
Network IN			
Connected to the Network OUT of a previous Renos unit or a Power Inserter.
USB			
Connect accessories to Renos, like the RFID reader or USB network adapter.
Network OUT		
Connected to the Network IN of a previous Renos unit or a Power Inserter.
Can also be left unconnected or connected to the customer network.
Mini USB service port		
Connect your laptop to configure the Renos system.
RS485 connector		
Connect to the smart deactivator(s).
Buzzer connector		
Connect to the buzzer.
Caution:
Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions.
status LEDs Renos
Green
On		
There is a Renos unit connected to the OUT port of this unit
Off		
There is no Renos unit connected to the OUT port of this unit
Blinking		
There is no device connected to the OUT port of this unit
On		
There is a Power Inserter connected to the OUT port of this unit
On		
There is an issue with the power supply at the OUT port of this unit (too little current drawn)
Blinking		
There is an issue with the power supply at the OUT port of this unit (too much current drawn)
Off		
There is no issue with the power supply at the OUT port of this unit
Blinking		
The operating system on the Renos unit is running
Off		
The operating system on the Renos unit is not running
Blinking		
The storage flash on the Renos unit is accessed
Off		
The storage flash on the Renos unit is not accessed
On		
The firmware on the Renos unit is running
Off		
The firmware on the Renos unit is not (yet) running
Blue
Red
Yellow
Green
Green
Disclaimer
Nedap intends to make this manual accurate and complete. However, Nedap does not warrant that the information contained herein covers all details, conditions
or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. Nedap disclaims any liability for damage
to property or personal injury resulting, in whole or in part, from improper installation, modification, use or misuse of its products. The information contained in
this document is subject to change without notice.
FCC and IC Compliance statement
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Cet appareil se conforme aux normes CNR 210 exemptés de license du Industry Canada. L’opération est soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interférence, et
(2) cet appareil doit accepter n’importe quelle interférence, y inclus interférence qui peut causer une
opération non pas voulu de cet appareil. Les changements ou modifications n’ayant pas été expressément approuvés par la partie responsable de la
conformité peuvent faire perdre à l’utilisateur l’autorisation de faire fonctionner le matériel.
FCC and IC Radiation Exposure Statement
This equipment complies with FCC and Canadian radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 5 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Cet équipement est conforme a CNR-102 limites énoncées pour un environne- ment non contrôlé. Cet équipement doit être installé et utilisé avec une distance
minimale de 5 cm entre le radiateur et votre corps. This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numérique de Classe B est conforme à la norme Canadienne ICES-003.
FCC Information to the user
Note: This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an
outlet on a circuit different from that to which the receiver.
NOTE: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. To
ensure compliance with FCC regulations, use only the shielded interface cables provided with the product, or additional specified components or accessories that
can be used with the installation of the product.
Declaration of Conformity
Hereby, De N.V. Nederlandsche Apparatenfabriek “Nedap” declares that the radio equipment type ASSY T325R RF is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: https://portal.nedapretail.com/
User manual
The complete instruction manual can be found at https://portal.nedapretail.com/


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01
Create Date                     : 2017:09:15 10:42:56+02:00
Metadata Date                   : 2017:09:15 10:43:04+02:00
Modify Date                     : 2017:09:15 10:43:04+02:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Instance ID                     : uuid:7e20100b-7c52-4114-8b69-893ea61b0f7c
Original Document ID            : xmp.did:FD7F1174072068119457DD866944A140
Document ID                     : xmp.id:aa4c6c4d-8acb-6a43-a4ab-e33b42d35cbc
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:ebfa2cb3-69e0-7d4c-b01c-18e7e8b681af
Derived From Document ID        : xmp.did:6A305B24E303E211A740EE653DA3658D
Derived From Original Document ID: xmp.did:FD7F1174072068119457DD866944A140
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2017:09:15 10:42:57+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CC 2017 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGDT325RRFMD

Navigation menu