Nedap N V TF2 Inductive Card Reader User Manual 14 D300X 08 Manual CGD TF2

N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Card Reader 14 D300X 08 Manual CGD TF2

14_D300X.08 Manual CGD-TF2

Download: Nedap N V TF2 Inductive Card Reader User Manual 14 D300X 08 Manual CGD TF2
Mirror Download [FCC.gov]Nedap N V TF2 Inductive Card Reader User Manual 14 D300X 08 Manual CGD TF2
Document ID1745150
Application IDW7AAbZEmuaDCUYomKvn6UA==
Document Description14_D300X.08 Manual CGD-TF2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.51kB (318843 bits)
Date Submitted2012-07-17 00:00:00
Date Available2012-07-17 00:00:00
Creation Date2012-04-25 13:34:10
Producing SoftwareWin2PDF x64 3.30 http://www.win2pdf.com
Document Lastmod2012-04-25 13:34:10
Document TitleMicrosoft Word - D300X.08 twin separatie CPT4SBS gb.doc
Document CreatorWin2PDF
Document Author: b.uninge

Hardware components for VC4/VC5
Twin Feeder 2
SEPARATION
SEPARATION/WEIGHING
CPT4SBS
CONTENTS
1 General
2 Operation
3 Installation
4 Set address
5 Adjust antenna with EWA transformer
6 Airflow Installation
7 Adjustment weigh computer
8 Display values
9 Internal test menu
10 Software settings
11 Trouble shooting
12 Spare part list
Enclosure : Figures
4 - 2012
D300X.eng
page
11
12
14
15
16
17
Nedap Agri
version 0.8
________________________________________________________________________
This documentation is part of the service manual VC4 CattleCode D300.
Documentation version 0.2, first edition.
Documentation version 0.3, weighing added
Documentation version 0.4, Eprom version 0.13 added
Documentation version 0.5, Welvaarts weighbridge added
Documentation version 0.6, Eprom version 4.00 added
Documentation version 0.7, Figure 2 : sensors connected to M+ instead of +23V
Documentation version 0.8, FCC text added
PROM overview CPT4SBS
1-2006
TwinFeeder
CPT4SBS 0.10
CPT4SBS 0.11
CPT4SBS 0.12
CPT4SBS 0.13
CPT4SBS 4.00
First field version
Weighing option added
Internal test menu : ROM/RAM test was not displayed
Identification : responder valid time shorter
-Suitable for TF model 2 and 4
- 2 hour activity added (Lacitvator, VC5 only)
FCC ID: CGD-TF2
IC: 1444A-TF2
Compliance statements (Part 15.19)
This device complies with Part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est
soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interférence, et
(2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une
opération non pas voulu de cet appareil.
Warning (Part 15.21)
Changes or modifications not expressly approved by party responsible for compliance could void the user’s
authority to operate the equipment.
This in particular is applicable for the antenna which can be delivered with this System.
______________________________________________________________________________________________
D300X
T/R Twin Separation
-1Version 0.8
________________________________________________________________________
______________________________________________________________________________________________
D300X
T/R Twin Separation
-2Version 0.8
________________________________________________________________________
General
This document contains the description of the software CPT4SBS in combination with
the T/R-Twin hardware for a separationbox.
The Transmitter/Receiver Separation Box Standard is used for identifying, separating
or separating/weighing of cows. The separation system uses one antenna.
CPT4SBS
The name of the EPROM is CPT4SBS x.xx. Description of the code : Cattlecode
Poiesz Twin VC4 Separation Box Standard.
Operation
Operation sequence
• Every cow is stopped at the hold-gate
• After identification of the responder the T/R sends a request for separation-data
• If weigh computer is connected, wait for weigh data
• When weigh data is received and separation data is received the separation gates
are set, the hold gate will open
• After hold gate is open the twin is waiting for IR2 (only if responder is out of the
antenna)
• As long as IR2 is activated the hold gate will not close
• When IR2 is free the hold gate will close
• When IR2 is free, IR3 is already activated
• Station is ready for the next cow as soon as IR3 is free
Operation sequence cow with no responder
• Cow is stopped at the hold-gate
• IR1 is activated, twin remains waiting for responder number
• After maximum ID time the cow will be sent to the default exit
______________________________________________________________________________________________
D300X
T/R Twin Separation
-3Version 0.8
________________________________________________________________________
Installation
The Nedap guarantee-regulations are only valid when the T/R is mounted and
installed as indicated in this chapter. The following is important :
• operating temperatures -10ºC .... +40ºC
• storage temperatures -25ºC .... +70ºC
• tightness IP 65, cover and cables mounted correctly
• input voltage 28 VDC +10% / - 20%, power supply at least 40 W (continuous)
• abs. max. voltage (+/-) 40 V DC, 35 V RMS, protected against reverse polarity
- never change a PROM when the power to the T/R is still switched on !
- shut off the power when service is needed for the station !
Antenna construction
The antenna must be installed around the station (see figure 5). When the HF-field is
adjusted correctly, the cows inside the station must be identified easily when they
are walking through the station.
Jumper settings
To install the T/R Twin correct, some jumper settings must be checked or changed.
Jumper J7 must be set to the left (LED is ON)
Jumpers J1 – J6 must be set to the right (brake off)
Antenna jumpers must be set to the lowest position (external adjust)
Wiring the T/R
Figure 2 shows an overview of the T/R-Twin cable-connections.
Cable C = coax, in this case it is important the shielding is connected to HF-
Max. cable-lengths, wire-ø's and cable colours
The cable-overviews in the figures all
show Lmax. at wire-ø = 0.8 mm.
The values for Lmax at ø=1.0 and ø=1.2 :
Lmax.(ø=1.0) = 1.5 x Lmax.(ø=0.8)
Lmax.(ø=1.2) = 2.0 x Lmax.(ø=0.8)
cable
colour
white
yellow
black
red
Shielding, grounding
In order to protect the VC-System for over-voltages, due to severe thunderstorms,
cable A in figure 2 must be a shielded cable. The cable-shield however may not be
used as a wire for current-supply. The cable-shield of cable A is as follows :
Transmitter / Receiver
connected to ground-terminal
N.B. All T/R electronics must be isolated from the parlour. This implicates that also
the T/R bottom has to be isolated from the T/R ground-terminal.
Warnings
• Due to guarantee-regulations, the entire T/R PCB (incl. metal plate) must be
changed.
• For continued protection against fire, always replace with same type and rating of
fuse.
______________________________________________________________________________________________
D300X
T/R Twin Separation
-4Version 0.8
________________________________________________________________________
Set Address
For communication the Transmitter / Receiver needs an address. Then the computer
knows where to send the information to. At the transmitter / receiver with help of the
display and the push button the stations address is configured.
The two segment display and the yellow push-button must also be used for several
adjustments of the Transmitter / receiver. A number of different codes will appear on
the display when the push-button is pushed, these codes represent the so-called
menus. Each menu on its turn is divided into a number of functions. By varying the
pushing time of the push-button, you will get access to the different menus and/or
functions.
The first time you switch on the power of the T/R, the display will show "0-". The
Transmitter / Receiver asks now for the first address. When an address is entered the
display will blank out and the transmitter / receiver returns to the normal status.
The address setting concerns the following menus and procedures (see figure 3):
• Address menu
- Set Address
- display Address
N.B. The address-range of all connected peripherals on the same controller channel
is from 1-50.
Remember that the used peripheral-address has to be unique on this controller
channel.
Changing addresses
When the display shows SA, the "Set Address procedure" is entered by pressing the
button until the display blinks. The procedure is as follows :
set decimal-digit
set unit-digit
display scrolls from 0- through 5display scrolls from x0 through x9
• to indicate that the "Set Address procedure" has been entered, the display will
show "0-"
• by pressing the button short, the next decimal will be displayed ("1-","2-"...."5-")
• the displayed decimal is entered by pressing the button until the display blinks
• when the decimal has been entered, the display will show "x0" (where x = entered
decimal), the unit-digit now can be entered
• by pressing the button short, the next unit will be displayed ("x1", "x2", .. , "x9")
• the displayed unit is entered by pressing the button until the display blinks
The following points should be noted
• the "Set Address procedure" can be quit by pressing the button until the
display blanks. The entered digits then are not stored
• the T/R will restart when the address is changed
Show addresses
When the display shows dA, the "display Address procedure" is entered by pressing
the button until the display blinks. The display then shows the T/R address.
______________________________________________________________________________________________
D300X
T/R Twin Separation
-5Version 0.8
________________________________________________________________________
Adjust antenna with EWA transformer
The antenna adjustment has to be done with help of the display, push button, P1 on the
T/R and the antenna transformer settings. Below you find the HF-menu, see also figure
3.
Jumper settings on the transmitter / receiver
When using an EWA antenna transformer jumpers J11 and J12 should be set to
position B
⇒
HF menu
• selection of responder type
Responder Select
• adjust antenna by means of tuning capacitor Ct
Adjust Antenna
• adjust transmitter-power by means of potentio meter P1
Adjust Power
• adjust receiver-sensitivity (0,1,2,3)
Adjust Squelch
• adjust neutrodynisation
Adjust Neutro
• Test identification
Identification
The antenna adjustment-procedure consists of several steps. It is essential that
these steps are executed in the sequence as in the manual described.
Responder Select
During T/R start up there is auto detect of T/R type, 120kHz (for rA and rP) or 134.2
kHz (for ri and r2)
rA = AM labels, X-ponder and Respactor (default)
rP = PM labels, ear button and Phase code responders
ri = ISO responder types (default)
r2 = Nedap 2 hour activity meter (Lactivator)
Select rS on the display and select the required type, press until display blinks to
store the setting.
Adjust antenna
HF menu, select H1 for antenna 1 or H2 for antenna 2
⇒
The antenna adjustment-procedure consists of several steps. It is essential that these
steps are executed in the sequence as described. First "AA", then "AP" and last "AS",
described in step 1, 2, 3 and 4.
While tuning Lt the following must be noted
• The tuning of Lt must be done with a non-metal screw-driver (e.g. plastic)
• This tuning of Lt requires a short circuit of the "Antenna adjust input" on the T/R,
see jumper settings.
• It is possible that the trimmer-coil must be turned so far out of the coil housing that
the transformer box does not close anymore. In that case, turn the trimmer-coil
completely in the coil housing. In this way the same adjustment can be achieved.
______________________________________________________________________________________________
D300X
T/R Twin Separation
-6Version 0.8
________________________________________________________________________
Step 1
Jumper setting on Antenna-Transformer
• measure the circumference of the antenna-loop
• set jumpers to combination as described in table on Antenna-Transformer PCB,
note that the highest possible number should be chosen.
e.g. Antenna circumference = 6 meters.
According to the table on the Antenna-Transformer PCB, 2 combinations are
possible :
NR.
Combination
Antenna length
A0 B0
5.8 - 8.2 meters
A0
B2
4.2 – 6.6 meters
In this example, the jumpers should be set to combination
2. (2 is highest number and shortest length)
Step 2
Transformer-ratio on the Antenna-Transformer and Lt adjustment
The transformer-ratio determines the HF-current through the loop-antenna, which
determines the power of the HF-field. In principle the highest transformation-ratio
should be selected. This however can be limited by the fact that the antenna-circuit
then can not be brought in resonance anymore (= highest value on the display).
13
neutro
Z/O M (HF+/-)
9:1
13
neutro
Z/O M (HF+/-)
11 : 1
13
neutro
Z/O M (HF+/-)
13 : 1
13
Z/O M (HF+/-)
neutro
Figuur :
Transformatieverhouding
aansluitingen
15 : 1
The following has to be done
• turn the trimmer coil (Lt) completely in the coil housing.
• connect HF-output of T/R (HF +/-) to input of ANT-T with the transformation-ratio
according to the table below for rough adjustment.
Note : The length of the example is about 6 m
Length of Antenna
till 3,5 m
3,6 - 4,7 m
4,8 - 6,6 m
6,7 or larger
Transformer ratio
15 : 1
13 : 1
11 : 1
9:1
• select AA (Adjust Antenna see figure 2) on the display, then push the button until
the display starts to blink.
• with P1 (figure 1) the displayed value must be set to 30
• after adjusting P1, the value must be adjusted with Lt (figure 1) on the EWA
transformer to a maximum value. Tune (with plastic screw driver) the trimmer Lt
on the antenna transformer until the highest point has been found (is highest
display value, this means when you are turning further in the same direction the
display value must go down after the highest level has been found, if not select a
different transformer ratio.)
• connect HF-output to the next transformer-ratio 9 : 1, or 11 : 1 (do not change HF+
and HF-), try if a higher value on the display can be found by tuning Lt.
• connect HF-output to the highest transformation-ratio (with the highest value on
the display) where it is still possible to find the highest point, this is the right
adjustment.
• When the right transformation ratio has been found Lt must be tuned to the
maximum
______________________________________________________________________________________________
D300X
T/R Twin Separation
-7Version 0.8
________________________________________________________________________
step 3
Adjust power
After correct processing the antenna adjustment procedure, step 1 and 2 are done
and Lt is adjusted (highest value is on the display now ), P1 must be adjusted with
help of AP.
When the display shows AP, the "Adjust Power procedure" is entered by pressing the
button until the display blinks. The display now shows the percentage of the
maximum transmitting-power of the T/R. The T/R is equipped with a power-limitter.
When the transmitted HF-power exceeds a certain level, the HF-current will be limited
automatically. To indicate this, the display will blink, after this point power-increase
(P1) is not desirable.
The tuning-procedure is as follows :
set power-level
tune P1 maximal until just before the point where the display
starts to blink
You can continue by pressing the button short
step 4
Adjust squelch procedure
The adjusted squelch determines the sensitivity of the receiver in the T/R. In case
e.g. calves outside the station are identified, the transmitted power can be reduced
("Adjust Power procedure") or the receiver-sensitivity can be reduced by means of the
squelch-adjustment.
Normally squelch does not have to be adjusted (default is automatically set
When the display shows AS, the "Adjust Squelch procedure" is entered by pressing
the button until the display blinks. The display now shows the actual sensitivity of the
receiver, a value from "-0" (most sensitive, i.e. default setting) until "-3" (least
sensitive).
By shortly pressing the button, the desired squelch can be adjusted. The setting can
be entered by pressing the button until the display blinks.
Advised and Default Squelch settings CPT4SBS
Twin Feeder Model 1
Squelch = 0
Twin Feeder Model 2 AM CODE
Squelch = -2
Twin Feeder Model 2 PM CODE
Squelch = -1
Note : AS can be used to reduce the HF-field if animals are identified outside the
station, check if the identification is still sufficient
______________________________________________________________________________________________
D300X
T/R Twin Separation
-8Version 0.8
________________________________________________________________________
Airflow Installation
• The main pressure has to be 85 P.S.I. (6 bar) With this pressure the main
cylinders are controlled. The speed of the out going cylinders is controlled by the
regulator at the point R and the speed in going cylinders by regulator at point S on
the control plate.
M+ Mx
AIR
______________________________________________________________________________________________
D300X
T/R Twin Separation
-9Version 0.8
________________________________________________________________________
Adjustment weigh computer
This weigh computer can automatically weigh animals. The weight is sent to the Twin
T/R and then transferred to the VC computer.
The weigh computer has 3 modes, namely:
• weighing mode
• calibration mode
• setting mode
TYPE W-2000
Charge
kg
GROSS
NET
TOTAL
GROSS/NET
Figure 3 :
Weigh computer
connections
TARE/ZERO
Weigh computer
TOTAL
PRINT
ON/OFF
TWIN Transmitter / Receiver
Pen 2
Rx Pen 3
Tx not used
+ Pen 1
Weigh platform
Horizontal floor level
Weighing mode
When the weigh computer is switched on, the computer will automatically go over to
the weighing mode. The computer is now ready for normal use.
Calibration mode
The calibration mode is selected to adapt the computer to the weighing platform or to
calibrate the computer. This is done as follows: Switch the computer on and hold
down the "TOTAL" key. After a standard text message, the computer gives a bleep
signal. You will now see the word "POS --" on the screen. Now release the "TOTAL"
key and press any key you like.
Set the computer to gross by pressing the "GROSS/NETT" key. The scale zero can
now be set. To do this, open up the weigh computer. Two potentio meters which have
to be calibrated are located on the PCB in the housing cover. The left hand potentio
meter is used to set the zero weight and the right hand potentio meter is used to set
the correct weight. Use the left hand potentio meter, set the computer to zero. If you
want to reduce the value, turn clockwise and if you want to increase it, turn in the
opposite direction. Now place a known weight on the scale, preferably about the
same weight as the animals to be weighed. Using the right hand potentio meter, set
the computer to the right weight. Remember, clockwise for higher values, and anticlock wise for lower values. When you want value's in pounds (lb) you have to turn
the weight to the lb value. Remove the calibration weight from the scale and check
the zero position on the computer. Correct if necessary. The computer is now
calibrated. It is possible to weigh normally again by simply switching the computer off
and on again.
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 10 Version 0.8
________________________________________________________________________
Setting mode
The behaviour of the weighing computer may be influenced by three parameters. To
change these parameters, the computer has to be in the setting mode. This is done
by switching the computer on and holding down the "TOTAL" and the "PRINT" key at
the same time. When the screen message has disappeared, the computer gives a
bleep signal and you will now see "P-" appear on the screen. Now release the two
keys and press the "GROSS/NETT" key once. The computer now displays "PI XX",
when XX represents the value of parameter 1. Therefore, you do not actually see "PI
XX", on the screen, but "PI 25", for example. The damping of the scales is set with
parameter1. This value can be set from 0 - 63, inclusive, when 0 indicates the
minimum damping. This adjustment is made with the "TOTAL" key increases the
value of the parameters, the "PRINT" key reduces it. (Best value of P1 = 10)
After setting the damping, you can switch over to the second parameter, P2. This is
done by pressing the "GROSS/NETT" key. Parameter 2 indicates the stable factor.
The computer only transmits data to the VC computer if the weight is "stable". "P2"
sets exactly how stable the weight must be. Possible values for "P2" are 1 - 99. At 1
the weight must be very stable and when at a value of 99 practically everything is
regarded as stable. (Best value of P2 = 15)
The third parameter P3 can be set by pressing the "GROSS/NETT" key once more.
The peak value of "P3" can be set between 1 - 5 inclusive. "P3" is a multiplying
factor. Normally "P3" is set at 1. If the "P3" is set to 5, the weight is multiplied by 5.
This weight is then displayed and may also be transmitted to the VC computer. After
setting "P1", "P2" and "P3", inclusive, the "GROSS/NETT" key has to e set once
more. The computer is now ready for use and does not have to be switched off and
on. The values "P1", "P2" and "P3", inclusive are stored even when the computer is
switched off. If the computer is switched to calibration mode, parameter "P3" is set to
1 automatically. This is still the case after leaving the calibration mode. Therefore, if
another multiplying factor is needed, this has to be set again after leaving the
calibration mode. (Best value of P3 = 1).
Summary
normal start
switching on with "TOTAL" key
left hand potention meter: zero setting
right hand side potention meter: weight setting
switching on with "TOTAL" and "PRINT"
key
P1
damping factor
0-63
P2
stability factor
1-99
P3
multiplying factor
1-5
weighing mode
calibration mode
setting mode
(i.e. 10)
(i.e. 15)
(i.e. 1)
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 11 Version 0.8
________________________________________________________________________
Display values
During operation, the program steps through different program-states which are
monitored on the display. This gives information about the state of the T/R and
therefore can be used as an extra service tool.
Start process : status 0-5
status
00
01
02
description of the status
processor-initialisation, opening network
wait for valid address, "SA"-menu is started automatically
No communication with process computer. Request for total
peripheral number. At installation the controller asks here for
peripheral information
request for external data
T/R under test
start-up process finished, task is killed
03
04
05
Display during normal operation
status
• left & right display
Description of the status
"--" when the T/R tries to identify a responder.
• decimal point left display
Cow-responder currently identified
• decimal point right display
HF1 field on
10
11
12
13
14
15
16
17
21
22
23
24
25
26
Initiate station
Wait for responder number
Sensor at antenna (IR1) occupied, no responder ID
Check gate positions (waiting for weigh data)
Wait for station to be free
Wait for hold gate sensor (IR2) to be active
Wait for hold gate sensor (IR2) to be free
Manual Control
Wait for separation sensor (IR3) to be active
Wait for cow-id (second cow identified, first cow has
not left yet)
Check gate position (second cow identified, first cow
has not left yet)
Wait for station to be free (second cow identified, first
cow has not left yet)
Wait for separation sensor (IR3) to be active
Responder still identified in antenna when IR2
became free
Wait for separation sensor (IR3) to be free
The display returns blank when the button is not touched for 30 minutes.
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 12 Version 0.8
________________________________________________________________________
Internal test menu
The different functions of the transmitter / receiver can be tested by means of the
push-button. A special program is build into the prom of the T/R. On the display this
option is called “It”, which stands for “Internal test”
The Internal test menu is a powerful service tool in case of system-service. The T/R
stores registered errors which can be displayed on demand of the trouble-shooter.
Also the T/Ran execute a complete self test on demand, the test results also are
displayed.
Internal test menu
− display Error procedure
− Self test menu :
Display error procedure
The detected errors are stored by the T/R itself and can be monitored on the display.
When the display shows dE, the “display Error procedure” is entered by pressing the
button until the display blinks. Two types of messages can be displayed by the T/R :
•
•
error-messages
warning-messages
(E1)
(E2, not used yet)
The procedure shows all registered errors on the display, one after the other,
proceeded by the message-type. First all error-messages will be shown, then all
warning-messages.
Error
Description
-01
no errors
Tare too high for more than 20
seconds
No HF1- current detected
09
10
11
12
Antenna error
RAM ERROR:
• data written does not match
data
ROM ERROR:
• calculated checksum does
not match checksum of
EPROM
how to handle
Clear the weighing platform or reset the
weighing unit
• Check antenna wiring
• Check HF-field (test responder)
• Replace T/R T-PCB
See error 09
Replace T/R T-PCB
Replace T/R T-PCB
Self test menu
When the display shows St, the “Self test menu” is entered by pressing the button
until the display blinks.
By shortly pressing the button, the T/R self tests can be selected. The selected test
is executed by pressing the button until the display blinks.
Test output 1 – 8
When the displays shows LX, the “test output procedure” is executed by pressing the
button until the display blinks. The device connected to the output will now be
switched ON
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 13 Version 0.8
________________________________________________________________________
Test input 1- 8
When the displays shows iX, the “test input procedure” is executed by pressing the
button until the display blinks.
01 = contact open
00 = contact closed
Test input Im7 –8
When the displays shows IX, the “test input procedure” is executed by pressing the
button until the display blinks.
01 = contact open
00 = contact closed
Test identification procedure
When the displays shows id, the "test identification procedure" is executed by
pressing the button until the display blinks. The HF-field now continuously will be on.
The ID-status is displayed as follows (switching HF1 / HF2):
-xx
= no responder identified
= responder identified ( xx = last two digits of responder number)
Test weighing unit
Weighing status is displayed, when weighing bridge connected.
-xx
= no weighing data read
= absolute weighing result (xx = last two digits of weighing data)
Test ROM / RAM
When the display shows rr, the "test ROM / RAM procedure" is executed by
pressing the button until the display blinks. The T/R now will restart, during which the
memory-tests are executed. The table underneath shows an overview of the return
values of these tests.
E1
E2
E3
RAM error
ROM error
RAM and ROM error
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 14 Version 0.8
________________________________________________________________________
10
PC-software settings VC4
In the installation program the following must be keyed in at the screen separation:
System >> Service >> Installation >> Installation
Recommended settings for CPT4SBS 0.12/0.13 and X-Act version 2.11/3.01
S = separation box
W = weighing / separation box
1. Weighing enable
Weighing enable / disable
2. Max ID Time
10
60
If the animal is not identified during this time, the animal will
be send to the default exit (sec.)
3. Not used
4. Default exit
Default exit
5. Scale type
1 = standard weigh computer
6. Max. weigh var.
50
Max. variation between two weighings (kg)
7. Max. tare weight
30
Max. tare weight (kg)
8. Min. weight
50
Min. accepted weight (kg)
9. Max. weight
1000 Max. accepted weight (kg)
10. Gate switch time
Wait time between gate actions (0.1sec.)
11. Sensor free y/n
12. Return to default
1= Station is free if sensor is NOT made
0= Station is free if sensor is made
1= Always return back to default gate settings
0= Set gate when new cow is identified
13. Not used
14. Max. track time
60
60
5 = no exits selected
1 = exit 1
2 = exit 2
Max. time an animal can occupy the station (sec.)
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 15 Version 0.8
________________________________________________________________________
11
PC-software settings VC5
First create locations. Select tab sheet locations at the left. Select the farm icon in
the tree and press button “NEW”. After saving the new location will appear in the
tree.
When ready creating locations, select button “service” and start scanning devices.
After scanning the devices connect the separation locations to the exits.
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 16 Version 0.8
________________________________________________________________________
11
Trouble shooting
symptom
T/R does not start
up display remains
blank
T/R does not start
up display shows
"E1, "E2" or "E3"
T/R does not start
up, display shows
"02"
Poor identification
cause
• no power
solution
• check power supply
• check wiring
•
RAM, ROM or both
failed
•
replace T/R PCB
•
T/R not supported by
the controller
communication fails
antenna badly adjusted
•
•
•
•
•
non-sensitive squelchadjustment
•
check T/R address
install the T/R at the PC
check communication wiring
Check T/R-power (P1)
perform "Adjust Antenna" readjust Lt if necessary
check adjusted squelch
•
•
•
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 17 Version 0.8
________________________________________________________________________
12
Spare part list
No. Article number
2805863
9835733
9808418
9852514
Description
E-prom CPT4SBS
Antenna transformer EWA, adjustable
Accessories antenna transformer, consisting of:
- bolt M4x30 (6x)
- bolt M4 (6x)
- washer spring A4 (6x)
- bolt M8x100 stainless steel (4x)
- bolt M8 stainless steel(6x)
- washer spring A8 stainless steel (10x)
- isolation plate antenna transformer (1x)
- pipe brace including nuts (2x)
- strip (2x)
Antenna-set walk through identification, consisting of:
9800263 Antenna strip stainless steel
9800271 Accessories Antenna, consisting of:
- bolt M8x25 stainless steel (10x)
- bolt M8 stainless steel (10x)
- washer spring A8 stainless steel (10x)
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 18 Version 0.8
________________________________________________________________________
TWIN 2
EPROM
9829601
X6
X7
X8
X4
J8
J9
J15
X9
VC3
VC4
J8
J9
PCF
VC4
C2
J12
J10
J11,12
EXTERN
ADJUST
C1
J11
J7
P1
J1
J1 t/m 6
BREAK ON
J6
J5
J4
J3
J2
+23V
I8
I7
+23V
+23V
I-
I-
I-
I-
I-
I-
I-
Im8
Im7
I6
I5
I4
II1
HF2+
M8
M7
M6
M5
M4
I3
M3
I2
Rx
Tx
M2
M1
HF1-
M+
M+
M+
M+
M+
M+
M+
M+
HF1+
EPROM
Micro processor module
Display’s
Drukknop
HF ID module
HF trimmer antenne 2 (C2)
HF trimmer antenne 1 (C1)
HF power potentio meter (P1)
Connector antenne 2
Connector antenne 1
+ 23 Volt
Ingang / uitgang connectors
VC3 connector
VC4 connector
J1 J2 J3 J4 J5 J6
J1
J7
J8
J10
J11
J15
X7
X6
X9
X8
X4
HF2-
LED “motor hardware safeguard” uit
RS232 connector
J1 - J6 “Enable brake” jumpers
Jumper “motor hardware safeguard” aan/uit
J8 - J9 jumpers VC3 - VC4
Jumper VC3 - VC4 communicatie kanaal
J11 - J12 Jumper HF1 en HF2
Jumper Phase code ID aan/uit
Signal ground
Responder signal
TP2
TP1
AGC
Figure 1 : overview T/R Twin PCB
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 19 Version 0.8
________________________________________________________________________
Cable nr.
# of wires
L.max. (m)*
coax
40
3**
10
* at wire-D = 0.8mm. (other D’s see text)
** Longer cable no problem, but not CE approved
1.
M+ / M1
Hold gate
2.
M+ / M2
Signal lamp
3.
M+ / M3
Not used
4.
M+ / M4
Entrance gate (only weigh bridge station)
5.
M+ / M5
Separation gate 1
6.
M+ / M6
Separation gate 2
7.
M+ / M7
Not used
8.
M+ / M8
Not used
9.
I- / I1 / M+
IR1, Cow detector
10.
I- / I2 / M+
IR2, Cow-detect through hold-gate
11.
I- / I3 / M+
IR3, Cow-leave through exits sensor
12.
I- / I4 / M+
Manual
13.
I5
Manual, entrance gate
14.
I6
Manual, hold-gate
15.
I7
Manual, separation gate 1
16.
I8
Manual, separation gate 2
17.
- / Rx / +
18.
+/-/D/C
Weigh bridge
Interface Bridge VC4 / X-act Controller
Figure 2: Overview T/R Separation cable connections
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 20 Version 0.8
________________________________________________________________________
Normal state : display is b lank or shows program state
Ad
HF
SA
Set Address
dA
Display Address
rS
rA
Resp. AM (X-ponder/Respactor)
rP
Resp. PM (Phase code)
ri
Resp. ISO
r2
Resp. ISO (Lactivator)
AA
Adjust Antenna
AP
Adjust Power
AS
Adjust Squelch
An
Adjust Neutrodynisation
id
Test Identification
H1
It
H2
Not used
dE
Display error
St
id
Test Identification
ui
Test Weighing
L-
Test Output 1 - 8
i-
Test Input 1 - 8
I-
Test Im7 - Im8
rr
Test ROM/RAM reboot
Figure 3 : overview T/R display-menus
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 21 Version 0.8
________________________________________________________________________
M10 bolt
PVC mounting part
Antenna-strip
ANT-T
nut + washer
antenna-wire
O 12.0 (2x)
6.0
antenna-strip
140.0
8.5 mm, bolt M8 x 16 stainless steel
pipe
isolation
12.5
Parlour : front view
25.0
12.5
All sizes in mm.
Material antenna : Stainless Steel strip 25x6 mm.
Material rod : galvanised, 1 " (inside Diameter)
ATTENTION:
no iron through the antenna
and no metal that could cause
a loop close to antenna
Antenna-parts
M10 bolt
PVC
dimensions as above
ANT-T
nut + washer
bended angle
antenna-wire
width depends on parlour-width
antenna-strip
(see also installation)
Parlour : front view
plastic pipe, necessary for
isolation of antenna from parlourframe (minimum 3 cm distance)
height = 2m.
Bottom side may be
poured in parlourcement, or mounted
to floor (bolts)
welded to each other
welding
ATTENTION: When installing in or on the floor, the antenna + installation material should not hit
iron. The in the floor present (concrete) iron can cause problems at the identification when there is
contact to the iron.
Figure 4 : Overview walk through antenna-construction
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 22 Version 0.8
________________________________________________________________________
Top view
Extra antenna-strip
O 9.0 (2x)
3.0
10
ANT-T
20.0
10
All sizes in mm.
Material antenna : Stainless Steel strip 20x3 mm.
antenna-strip
1200
Main-part antenna-strip
900
200
500
1000
O 9.0 (7x)
20
120
30
880
extension (welded)
antenna
transf.
800 (=max)
floor
120
> 70 mm
iron
When installing in or on the floor, the antenna + installation material should not hit iron. The antenna can be
installed in or on the floor but the reinforcement in the floor must be in sufficient distance.
Figure 5 : overview construction walk-over antenna (only for foot types)
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 23 Version 0.8
________________________________________________________________________
I-
- (Output 4)
I4
Manual on/of
M6
Gate 2
I8
M5
Gate 1
I7
M1
Exit gate
I6
M4
Entrance gate
I5
(only weigh bridge)
M+
+ (Output 4)
Figure 6: Manual control box connections since CPT4SBS 0.11
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 24 Version 0.8
________________________________________________________________________
1000 mm
800 mm
IR1
IR3
IR2
IR3
HF2
300 mm
600 mm
100 mm
1200 mm
Figure 5: overview IR and antenna positions (2 IR sensors before separation door)
1000 mm
800 mm
IR3
IR1
IR2
IR3
HF2
IR3
300 mm
600 mm
100 mm
1200 mm
Note 1: Before the cow leaves IR2, the cow must be out the antenna field
Note 2: Before the cow comes into IR3, the cow must be out of the antenna field
Max width of the box 80 cm, In case of small cows it is better to make it as small as possible
Figure 7: overview IR and antenna positions (3 IR sensors at separation door)
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 25 Version 0.8
________________________________________________________________________
100 mm
IR1
IR2
IR3 IR3
1200 mm
HF1
100 mm
600 mm
1200 mm
FRONT LEG ID
1300-1700 mm
IR1
IR2
IR3 IR3
1200 mm
HF1
100 mm
600 mm
1200 mm
BACK LEG ID (antenna position depending on cow length)
Figure 8 : overview dimensions separation box with foot identification
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 26 Version 0.8
________________________________________________________________________
1000 mm
800 mm
IR1
IR2
IR3 IR3
HF1
300 mm
600 mm
100 mm
1200 mm
Figure 9 : overview dimensions separation box with identification on the side (ear button
identification)
______________________________________________________________________________________________
D300X
T/R Twin Separation
- 27 Version 0.8

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 28
Producer                        : Win2PDF x64 3.30 http://www.win2pdf.com
Create Date                     : 2012:04:25 13:34:10+02:00
Modify Date                     : 2012:04:25 13:34:10+02:00
Title                           : Microsoft Word - D300X.08 twin separatie CPT4SBS gb.doc
Creator                         : Win2PDF
Author                          : b.uninge
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGD-TF2

Navigation menu