Nedap N V VELOS5 Inductive Proximity Card Reader User Manual 5277434 Quick start VP1004 1 1

N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Proximity Card Reader 5277434 Quick start VP1004 1 1

User manual

Download: Nedap N V VELOS5 Inductive Proximity Card Reader User Manual 5277434 Quick start VP1004 1 1
Mirror Download [FCC.gov]Nedap N V VELOS5 Inductive Proximity Card Reader User Manual 5277434 Quick start VP1004 1 1
Document ID1584326
Application IDEII1iaTqlBfv5Q6YDYGdnQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.73kB (371579 bits)
Date Submitted2011-11-21 00:00:00
Date Available2011-11-21 00:00:00
Creation Date2011-09-01 14:37:02
Producing SoftwarePDFlib 3.03 (Win32)
Document Lastmod0000-00-00 00:00:00
Document TitleMicrosoft Word - 5277434 Quick start VP1004 1.1
Document CreatorWin2PDF http://www.daneprairie.com
Document Author: b.uninge

Quick start
VP1004 ISO Reader Multiplexer
The Velos VP1004 is a Velos component that is used to identify animals. The VP1004 must be
installed in a V-box. A VP1004 is connected to the Velos CAN-bus and controlled by a VP8001 (VPU).
Inputs / Outputs / Antennas
- 8 antennas, auto scanning one by one (max 10x VP1004 per VP8001)
- 2 outputs available to activate e.g. lights and 2 inputs for reading e.g. switches
Power
Supply
VP2001
VP8001
To PC (LAN ethernet)
max 3m
VP1004
VP1004
Antenna 1-8
Antenna 17-24
VP1004
Next VP1004
Next VP1004
Antenna 9-16
VP1004
Antenna 25-32
FCC ID: CGDVELOS5 and IC: 1444A-VELOS5
Compliance statement (part15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Déclaration Conformité
Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis aux deux
conditions suivantes:
(1) cet appareil ne doit causer aucune interférence, et
(2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas voulu
de cet appareil.
Warning (part15.21)
Changes or modifications not expressly approved by party responsible for compliance could void the user s authority to operate
the equipment.
This in particular is applicable for the antenna which can be delivered with the VP4001 System.
VP1004- ISO Reader Multiplexer - Quick start
9-2011 Doc.part.no. 5277434 45.01B 1/ 4
VP8001 (1)
VP8001 (2)
LAN
VP1004
VP1004
VP1004
Velos cable Lmax = 80m
Max = 5x VP1004
Velos cable Lmax = 80m
VP1004
Max = 5x VP1004
Connections
Velos cable OUT
(to next VP1004)
orange white
orange
blue white
blue
black
red
antenna
orange white
orange
blue white
blue
black
red
Velos cable IN
Details VP1004 inputs and outputs
Vin
Input voltage 24 VDC, +20% -20%
Minus
CAN
CAN high (cable twisted pair with CL)
CH
CAN low (cable twisted pair with CH)
CL
Shielding of CAN-bus cable
SYNC
Synchronisation (no plus or minus, cable must be twisted pair)
See above
I/O 1 .. 2
Output max 400mA
Output max 400mA / 1.7A input
Minus for output (O) and minus input (I)
Input
ANTENNA
Antenna (core)
Antenna (shield of coax cable)
F SYNC
Frequency synchronisation FI=in FO=out
FI/FO
VP1004- ISO Reader Multiplexer - Quick start
9-2011 Doc.part.no. 5277434 45.01B 2/ 4
Details Velos cable
Part No. 7705310
Red (+)
Black (-)
Power
1,5 mm2
Blue (Ch)
Blue/white (Cl)
Shield
Communication
0,34 mm2
Twisted pair shielded
Orange (Sync)
Orange/white (Sync)
Shield
HF Synchronisation
0,34 mm2
Twisted pair shielded
Antennas
A VP1004 has an automatic tuning module. The status is shown with LED indicators.
Only V-sense antennas types can be used. Not all types are compatible, check compatibility before
use.
Display menu
display
push button
DISPLAY ADDRESS
Shows the actual address
SET ADDRESS
Change the address
ANTENNA POWER
Min/max 10 / 99. Normally set to 99. Possible to set a lower value.
ANTENNA SENSITIVITY SQUELCH
Min/max 9 / 0. Normally set to 0. Possible to set a lower value.
SIGNAL LEVEL FDX
Shows signal level measured by the FDX receiver
SIGNAL LEVEL HDX
Shows signal level measured by the HDX receiver
TEST IDENTIFICATION
Shows last 2 digits of a tag number
DISPLAY ERROR
Shows error code
TEST OUTPUT
L1
L5
TEST INPUT
I1
i5
SETTINGS TO DEFAULT
All HF settings back to factory settings (enter 99)
Press button until blinking
Press button short
VP1004- ISO Reader Multiplexer - Quick start
To leave menu:
press button until display is empty
9-2011 Doc.part.no. 5277434 45.01B 3/ 4
LED indicators
POWER
STATUS
Display
V in
V out
LAST
O1 .. O2
I1 .. I2
ID
on
off
Green on
off
Blue
Slow breathing
Fast blinking
Address indicated
Green on
off
Orange
Orange blinking
Red
Green on
off
Orange blinking
Red blinking
Green on
off
Orange blinking
Red
Red blinking
Green on
off
Red blinking
Green on
off
Green one by one
Green on
Red on
Power on
No power
Operating ok
Downloading or error during download
No communication
Communication status ok
Input power applied
No power
Low power, lower then 20V
Wrong CAN-bus connection, Vin and Vout swapped
Error, plus and minus swapped
Output power
No power
Low power
Error, plus and minus swapped
V-pack is last one on the CAN-bus
V-pack is not last one on the CAN-bus
CAN-bus error and last V-pack on CAN-bus
CAN-bus error
CAN-bus warning / wrong connected
Output on
Output off
Output error / overload
Input contact open
Input contact closed
Antenna ok
Antenna ok and tag identified
Antenna error / not connected / not tuned correctly
Specifications VP 1004
Dimensions
143 x 120 x 68 mm LxWxH (excluding mounting rail) Weight: ± 360 gr
CAN
CAN-bus communication 125 kBit
Power
Input voltage 25 VDC, +20% -20%
Min power consumption 300 mA with antenna switched on
Protected against reverse connection power supply
Software
Downloadable by the CAN network
Inputs
Reading inputs, analog (0-40V) and digital. Suitable for NPN and PNP sensors.
Outputs
Max. 0.4 Amp by current limiter, short-circuiting protected
Antennas
800 µH. Different types possible.
Detection distance
Varies per antenna
Synchronization
Synchronization according to ISO 11785 / 24631-6
Environment
Temperature: Operating: -10 55 °C, Storage: -25 70 °C
Relative humidity: 10 93% non condensing
IP class
IP 30. When installed in V-box IP 65 (cover and cables installed correctly !)
Always use a NEDAP power supply. The Nedap guarantee-regulations are only valid when is installed as
indicated in this manual. Install data cables at a safe distance from (high) powered cables
For more detailed information contact your local Nedap supplier or check the internet site.
This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no
licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and
availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in
part, without the written consent of the publisher.
© Nedap N.V., AGRI P.O. Box 104 NL-7140 AC GROENLO The Netherlands
VP1004- ISO Reader Multiplexer - Quick start
9-2011 Doc.part.no. 5277434 45.01B 4/ 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Title                           : Microsoft Word - 5277434 Quick start VP1004 1.1
Creator                         : Win2PDF http://www.daneprairie.com
Author                          : b.uninge
Create Date                     : 2011:09:01 14:37:02
Producer                        : PDFlib 3.03 (Win32)
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGDVELOS5

Navigation menu