Neptune Technology Group CMIU-VZW-1 Water meter reading equipment User Manual FCC Part 15

Neptune Technology Group Inc. Water meter reading equipment FCC Part 15

Manual

Download: Neptune Technology Group CMIU-VZW-1 Water meter reading equipment User Manual FCC Part 15
Mirror Download [FCC.gov]Neptune Technology Group CMIU-VZW-1 Water meter reading equipment User Manual FCC Part 15
Document ID2899037
Application IDbo9phKayCPvqPbpjtjTaVg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.65kB (320675 bits)
Date Submitted2016-02-08 00:00:00
Date Available2016-08-06 00:00:00
Creation Date2017-11-17 15:11:53
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-11-17 15:11:53
Document TitleFCC Part 15
Document CreatorAdobe Acrobat 11.0.14
Document Author: Brooke Copeland

Certification Exhibit
FCC ID: P2SCMIU-VZW-1
FCC Rule Part: 15.247
ACS Project Number: 15-3049
Manufacturer: Neptune Technology Group
Model: CMIU
Manual
2320 Presidential Drive, Suite 101, Durham, NC 27703 USA Voice: 919-381-4235 Fax: 770-831-8598
CELLULAR MIU INSTALLATION AND MAINTENANCE GUIDE
Celluar MIU Installation and Maintenance Guide
E-Cod
E-Cod
Cellular MIU Installation and Maintenance Guide
Copyright
This manual is an unpublished work and contains the trade secrets and confidential information of
Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in
whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission
of Neptune Technology Group Inc. All rights to designs or inventions disclosed herein, including the right to manufacture, are
reserved to Neptune Technology Group Inc.
The information contained in this document is subject to change without notice. Neptune reserves the right to change the
product specifications at any time without incurring any obligations.
Trademarks used in this manual
R900, ARB, ProRead, and E-Coder are registered trademarks of Neptune Technology Group Inc. Other brands or product
names are the trademarks or registered trademarks of their respective holders.
FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference,
This device must accept any interference received, including interference that may cause undesired operation.
Any Change or modification to the product is not expressly approved by Neptune and could void the user's authority to operate the device.
This equipment complies with the FCC radiation exposure limits set forth in an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the equipment and the user's body.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Cellular MIU Installation and Maintenance Guide
Neptune Technology Group Inc.
Literature No. IM CMIU 11.15
1600 Alabama Highway 229
Part No. XXXXX-XXX
Tallassee, AL 36078
Tel: (800) 633-8754
Fax: (334) 283-7293
Copyright © 2015
Neptune Technology Group Inc.
All Rights Reserved.
Contents
Product Description
Specifications
Electrical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Encoder Register Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications - CMIU MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Installation Guidelines
Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety and Preliminary Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Verifying/Preparing the Encoder Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation of a Register (Non Pre-Wired or Potted Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Wall Installation
Installing the Cellular MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Removing the Main Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Applying the Scotchloks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Activating and Completing the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Contact Information
By Phone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
By Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
By Email . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
CMIU Installation and Maintenance Guide
iii
Contents
Notes:
iv
CMIU Installation and Maintenance Guide
Figures
Figure
10
11
12
13
14
Title
Page
Cellular MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Wiring a Neptune Encoder Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
MIU Color Code for Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cable Threaded Around Strain Relief Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Application of the Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Covering the Terminal Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Wall MIU Main Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Mounting Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Gel Cap Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
MIU Color Code for Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cable in Back of Mounting Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cable Exit Notch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Securing Mounting Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Activating the MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
CMIU Installation and Maintenance Guide
Figures
Notes:
vi
CMIU Installation and Maintenance Guide
Tables
Table
Title
Page
Recommended Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Recommended Materials. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CMIU Installation and Maintenance Guide
vii
Tables
Notes:
viii
CMIU Installation and Maintenance Guide
1 Product Description
This section provides a general description of the Neptune Technology Group cellular
meter interface unit (subsequently referred to as CMIU).
The CMIU by Neptune is a compact electronic device that collects meter reading data
from an encoder register. It then transmits the data for collection. The collected data is
stored and downloaded into the utility billing system for processing.
The CMIU is easily installed and operates within the cellular frequencies.
Figure 1 Cellular MIU
The CMIU does require field programming.
Product Description
CMIU Programming
The CMIU does require field programming.
Low Battery Emissions
The CMIU stops RF transmissions when the battery discharges below normal the
operating voltage.
CMIU Installation and Maintenance Guide
2 Specifications
This section provides you with the specifications for the CMIU.
Electrical Specifications
The power is supplied by a Lithium battery.
Encoder Register Interface
Supported Encoder Maximum Cable Length
Neptune ARB® V1
300 feet (91 meters)
Neptune ProRead™ and E-Coder®
500 feet (152 meters)
Sensus Protocol registers
200 feet (61 meters)
Meets manufacturer’s published specifications for wire length between encoder and remote receptacle. The length is
based on solid three conductor wire, 22 AWG.
Specifications - CMIU
Environmental Conditions
Operating Temperature
-22° to 149°F (-30° to 65°C)
Storage Temperature
-40° to 158°F (-40° to 70°C)
Operating Humidity
0 to 100% Condensing
Register Reading
8 digits
MIU ID
10 digits
Functional Specifications
CMIU Installation and Maintenance Guide
3 General Installation Guidelines
This section describes tools, materials, and general installation information for the CMIU.
Tools and Materials
Tables 1 and 2 show the recommended tools and materials you need to successfully install
the CMIU.
It is possible that some items do not apply to your specific installation, or the list does not contain
all required tools or materials.
Table 1 Recommended Tools
Item
Description/Recommendations
Use
Took Kit
Contains standard tools including:
•
Assorted screwdrivers
•
Needle-nose pliers
•
Wire stripper
•
Diagonal cutters
•
Electrician’s knife
•
Hammer
•
Crimping tool
Part # 5500-158
Perform various installation
procedures.
Magnet
6 lb. force
Part # 12287-001
Activating the MIU.
CMIU Installation and Maintenance Guide
General Installation Guidelines
Table 2 Recommended Materials
Item
Description/Recommendation
Use
Cable
Solid 3 conductor #22 AWG (black/
green/red) Part # 6431-352
Connect MIU to encoder
register.
Moisture Protection
Compound
Novaguard sealant
Part # 96018-072
Cover exposed wires
and terminal screws on
register and MIU.
Scotchloks
Part # 8138-125
Connect wall MIU or
replacement pit MIU to
encoder register.
Site Work Order
Documentation provided by your
utility
Receive and record
information about the
work site.
Safety and Preliminary Checks
Observe the following safety and preliminary checks before and during
each installation.
•
Verify that you are at the location specified on the site work order.
•
Verify that the site is safe for you and your equipment.
•
Notify the customer of your presence and tell the customer that you
need access to the water meter.
•
Write in the ID number(s) of the MIU you are about to install, if the
site work order does not have an MIU ID number.
•
Verify that the ID number(s) matches the ID number(s) on the MIU
you are about to install, if the site worker already has an MIU ID
number.
Verifying/Preparing the Encoder Register
The CMIU is designed for use with the following encoder registers:
•
ARB V
•
ProRead
•
ProRead AutoDetect
•
E-Coder
•
Competitive registers using Sensus which include: Sensus ECRII,
ICE, iPerl, OMNI and electronic register; also Hersey/Mueller
Translator, Badger ADE, and HR E|LCD.
Before installing an MIU, the encoder register must be correctly wired
and/or programmed to work with the MIU. E-Coder registers do not
require programming.
CMIU Installation and Maintenance Guide
General Installation Guidelines
When a ProRead encoder register is used, the non-AutoDetect ProRead
register must be programmed for three-wire mode.
If connecting the MIU to a new ProRead encoder register, or if a threeconductor cable is already connected to a ProRead encoder register,
ensure that the ProRead register is programmed for three-wire mode
using the ProRead programmer and its RF/MIU 6, 8, or 10ID TDI
format. This can be accomplished through the ProRead receptacle
before removing the receptacle.
Installation of a Register (Non Pre-Wired or Potted Only)
Before wiring the pit encoder register, make sure the cable is long
enough. When the installation is complete, the pit lid can be
removed easily without straining the cable.
Use only 22 AWG cable to make the connection from the encoder
register to the MIU.
Remove the terminal screw cover from the encoder register.
Strip off ¾ inch of jacket from the cable, leaving only the three
insulated wires.
Take precautions not to nick or cut the insulation on the three wires,
strip off ½ inch of insulation from each of the three wires.
Figure 2 Wiring a Neptune Encoder Register
CMIU Installation and Maintenance Guide
General Installation Guidelines
Figure 3 MIU Color Code for Wires
If required, connect the three conductor wires to the encoder
register’s terminals per the manufacturer’s instructions. See Figure
2 and Figure 3.
Thread the cable around the strain relief posts of the encoder. See
Figure 4.
Figure 4 Cable Threaded Around Strain Relief Posts
Apply sealant liberally and ensure that it encapsulates the terminal
screws and exposed wires. See Figure 5.
Neptune requires Novaguard G661 sealant or Dow Corning compound 4.
CMIU Installation and Maintenance Guide
General Installation Guidelines
Figure 5 Application of the Sealant
Any leak point can cause a reading failure in a submerged meter setting.
Snap the cover onto the encoder register. See Figure 6.
Figure 6 Covering the Terminal Screws
10 Run the cable to the MIU and fasten it securely.
•
•
CMIU Installation and Maintenance Guide
Do not exceed maximum cable lengths as defined in “Specifications CMIU” on page 2.
If the encoder register is prewired and potted, use Scotchloks for connecting the register to the MIU.
4 Wall Installation
This chapter provides instructions for installing the CMIU.
Installing the Cellular MIU
Removing the Main Housing
Complete the following steps to install the wall MIU.
Remove the main housing from the mounting adapter.
The Hi-Lo fastener for securing the main MIU housing
to the adapter plate is shipped separately.
Set screw
Figure 7 Wall MIU Main Housing
Cable
StudyFigure 8 and the location requirements, then decide how to install the MIU and
mount the adapter with set screw positioned at bottom.
entry
Pipe clamp
Cable exit notch
A variety of holes in the mounting adapter allows for a
quick and easy installation.
•
The cable enters through the bottom or rear cable entry of the mounting adapter.
•
When the MIU replaces a receptacle, use the appropriate holes to allow reuse of
the receptacle’s original mounting holes. SeeFigure 8.
•
When mounting the MIU to a pipe, use the bolt hole for pipe mounting to bolt the
mounting adapter to a pipe clamp.
Figure 8 Mounting Adapter
CMIU Installation and Maintenance Guide
Wall Installation
Applying the Scotchloks
Using Scotchloks Gel Caps, connect the register wires to the pigtail
from the MIU. SeeFigure 9.
Pair the wires according to the color diagram in Figure 10.
Gel caps
Figure 9 Gel Cap Connections
Figure 10 MIU Color Code for Wires
Strain relief guide
Slide the paired wires into the grooves provided until they seat into
the back of the gel cap.
Using an appropriate crimping tool, firmly squeeze the gel cap to
ensure a good connection.
Repeat this process until all connections are complete.
For rear cable entry, store excess wire and Scotchloks in the hollow
cavity in the back of the MIU using the strain relief guides as shown
inFigure 11.
Cable exit notch
Figure 11 Cable in Back of Mounting Adapter
CMIU Installation and Maintenance Guide
Wall Installation
Continue to guide the remaining wire through the cable exit notch
at the bottom right side of the MIU as shown inFigure 12.
Slide the tongue on the top of the MIU into the groove on the top of
the mounting adapter.
Secure the MIU to the mounting adapter using the set screw.
SeeFigure 13.
Position the magnet against the left side of the MIU directly in line
with the Neptune logo, and swipe it bringing it from the side and
around the corner to the top to activate the MIU. SeeFigure 14.
Cable exit notch
Figure 12 Cable Exit Notch
Activating and Completing the Installation
Set screw
Figure 13 Securing Mounting Adapter
End swipe here
Figure 14 Activating the MIU
10
CMIU Installation and Maintenance Guide
5 Contact Information
Within North America, Neptune Customer Support is available Monday through Friday,
7:00 AM to 5:00 PM Eastern Standard Time by telephone, email, or fax.
By Phone
To contact Neptune Customer Support by phone, complete the following steps.
Call (800) 647-4832.
Select one of the following options:
•
Press 1 if you have a Technical Support Personal Identification Number (PIN).
•
Press 2 if you do not have a Technical Support PIN.
Enter the six-digit PIN number and press #.
Select one of the following options.
•
Press 2 for Technical Support.
•
Press 3 for maintenance contracts or renewals.
•
Press 4 for Return Material Authorization (RMA) for Canadian Accounts.
You are directed to the appropriate team of Customer Support Specialists. The
specialists are dedicated to you until the issue is resolved to your satisfaction. When
you call, be prepared to give the following information.
•
Your name and utility or company name.
•
A description of what occurred and what you were doing at the time.
•
A description of any actions taken to correct the issue.
By Fax
To contact Neptune Customer Support by fax, send a description of your problem to
(334) 283-7497. Please include on the fax cover sheet the best time of day for a Support
Specialist to contact you/
By Email
To contact Customer Support by email, send your email message to
hhsupp@neptunetg.com.
CMIU Installation and Maintenance Guide
11
Contact Information
Notes:
12
CMIU Installation and Maintenance Guide
Neptune Technology Group Inc.
1600 Alabama Highway 229
Tallassee, AL 36078
USA
Tel: (800) 633-8754
Fax: (334) 283-7293
Neptune Technology Group (Canada) Ltd.
7275 West Credit Avenue
Mississauga, Ontario
L5N 5M9
Canada
Tel: (905) 858-4211
Fax: (905) 858-0428
Neptune Technology Group Inc.
Ejército Nacional No. 418
Piso 12, Desp. 1201-1202
Col. Chapultepec Morales
Delegación Miguel Hidalgo
11570 México, Distrito Federal
Tel: (525) 55203 5294 / (525) 55203 5708
Fax: (525) 55203 6503
IM CMIU 11.15 Part No. XXXXX-XXX © Copyright 2015, Neptune Technology Group Inc. Neptune is a registered trademark of Neptune Technology Group Inc.
TAKE CONTROL
neptunetg.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Author                          : Brooke Copeland
Create Date                     : 2016:01:25 16:20:14-05:00
Modify Date                     : 2016:01:25 16:20:51-05:00
Has XFA                         : No
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2016:01:25 16:20:51-05:00
Creator Tool                    : Adobe Acrobat 11.0.14
Format                          : application/pdf
Title                           : FCC Part 15
Creator                         : Brooke Copeland
Document ID                     : uuid:e0feae2a-a5d3-4b57-9d2a-b7aaa94e1c8c
Instance ID                     : uuid:f0617120-c05b-4ab7-b2e6-fb81ee958d20
Producer                        : Adobe Acrobat 11.0.14
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P2SCMIU-VZW-1

Navigation menu