R

8 PORT
10/100/1000 Mbps

Copper Gigabit Switch
Installation Guide
MODEL

GS 508T

© 2001 by NETGEAR, Inc. All rights reserved.

Trademarks
NETGEAR is a trademark of NETGEAR, Inc. All other trademarks and registered trademarks are the
property of their respective owners.

Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves
the right to make changes to the products described in this document without notice.
NETGEAR does not assume any liability that may occur due to the use or application of the product(s)
or circuit layout(s) described herein.

Certificate of the Manufacturer/Importer
It is hereby certified that the NETGEAR Model GS508T Copper Gigabit Switch has been suppressed in
accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992.The operation of some equipment (for example, test transmitters) in accordance with the regulations may, however,
be subject to certain restrictions. Please refer to the notes in the operating instructions.
Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on
the market and has been granted the right to test the series for compliance with the regulations.

Voluntary Control Council for Interference (VCCI) Statement
This equipment is in the first category (information equipment to be used in commercial and/or industrial
areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data
Processing Equipment and Electronic Office Machines that are aimed at preventing radio interference in
commercial and/or industrial areas.
Consequently, when this equipment is used in a residential area or in an adjacent area thereto, radio interference may be caused to equipment such as radios and TV receivers.

ii

Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including interference that may cause
undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

EN 55 022 Declaration of Conformance
This is to certify that the NETGEAR Model GS508T Copper Gigabit Switch is shielded against the
generation of radio interference in accordance with the application of Council Directive 89/336/EEC,
Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
Warning: This is a Class A product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take appropriate measures.

Canadian Department of Communications Radio Interference Regulations
This digital apparatus (NETGEAR Model GS508T Copper Gigabit Switch) does not exceed the Class A
limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of
the Canadian Department of Communications.

Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (NETGEAR Model GS508T Copper Gigabit Switch) respecte les limites de
bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règlement sur le
brouillage radioélectrique du ministère des Communications du Canada.

iii

Customer Support
For assistance with installing and configuring your NETGEAR system or with questions or problems
following installation:
• Check the NETGEAR Web page at http://www.NETGEAR.com.
• Call Technical Support at the phone number listed on the Support Information Card that shipped with
your switch.
• Email Technical Support at support@NETGEAR.com.
Defective or damaged merchandise can be returned to your point-of-purchase representative.

Internet/World Wide Web
NETGEAR maintains a World Wide Web home page that you can access at the universal resource locator
(URL) http://www.NETGEAR.com. A direct connection to the Internet and a Web browser such as
Internet Explorer or Netscape are required.

iv

CONTENTS
CHAPTER 1
Introduction
Features
Package Contents

1-1
1-2

CHAPTER 2
Physical Description
Front Panel
LEDs
Rear Panel

2-1
2-2
2-2

CHAPTER 3
Applications
Desktop Switching
Segment Switching and Bridging from 100 Mbps to 1000 Mbps

3-1
3-2

CHAPTER 4
Installation
Preparing the Site
Installing the Switch on a Flat Surface
Installing the Switch in a Rack
Connecting Devices to the Switch
Verifying Installation

4-1
4-1
4-2
4-2
4-3

CHAPTER 5
Troubleshooting
APPENDIX A
Technical Specifications

contents

v

APPENDIX B
Connector Pin Assignments
RJ-45 Plug and RJ-45 Connector

B-1

APPENDIX C
Cabling Guidelines
Using 1000BASE-T Gigabit Ethernet over Category 5 Cable
Overview
Cabling
Length
Return Loss
Near End Cross Talk (NEXT)
Patch Cables
Conclusions
Fast Ethernet Cable guidelines
Category 5 Cable
Category 5 Cable Specifications
Twisted Pair Cables for 1000BASE-TX
Patch Panel and cables

C-1
C-1
C-1
C-1
C-2
C-2
C-3
C-3
C-3
C-4
C-4
C-5
C-6

contents

vi

FIGURES
Figure 1-1.

Model GS508T Switch Package Contents

1-2

Figure 2-1.

Front Panel of the Model GS508T Switch

2-1

Figure 2-2.

Rear Panel of the Model GS508T Switch

2-2

Figure 3-1.

Model GS508T Switch Used as a Desktop Switch

3-1

Figure 3-2.

Model GS508T Switch Used as a Segment Switch

3-2

Figure 4-1.

Attaching Mounting Brackets

4-2

Figure 4-2.

Connecting to the Model GS508T Switch

4-3

Figure B-1.

RJ-45 Plug and RJ-45 Connector
with Built-in LEDs

B-1

Figure C-1.

Straight-through Twisted Pair Cable

C-5

Figure C-2.

Crossover Twisted Pair Cable

C-5

Figure C-3.

Category 5 UTP Patch Cable with
Male RJ-45 Plug at Each End

C-6

contents

vii

TABLES
Table 2-1.

LED Descriptions

2-2

Table 4-1.

Operating Environment Requirements

4-1

Table 5-1.

Troubleshooting Information

5-1

Table B-1.

10/100/1000 Mbps RJ-45 Plug and RJ-45
Connector Pin Assignments

B-2

Electrical Requirements of Category 5 Cable

C-4

Table C-1.

contents

viii

CHAPTER 1: INTRODUCTION
R

The NETGEAR Model GS508T 8-Port Copper Gigabit Switch provides you with a
low-cost, high-performance network solution and is designed to anchor and interconnect 10/100/1000 megabits per second (Mbps) workgroups using copper Gigabit links.
Features
The Model GS508T switch has the following key features:
• Eight full-duplex copper Gigabit ports with standard RJ-45 connectors
• Automatic address learning function to build the packet-forwarding
information table
The table contains up to 8,000 media access control (MAC) addresses (that is, the
switch can support networks with as many as 8,000 devices).
• Full-duplex mode to double throughput of point-to-point connections by letting individual ports transmit and receive concurrently when the other end also supports
full-duplex mode
• Wire-speed filtering and forwarding of the traffic with no delay
• Store-and-forward intelligent processing to minimize erroneous packets on the network
• Easy Plug and Play installation with no software to configure, which saves time and
minimizes the potential for configuration errors
• Operation at speeds of 10, 100, or 1000Mbps on each port
• Flow control traffic management to ensure no packets are dropped if there are
back-ups or bottlenecks in the network

introduction

1-1

Package Contents
Figure 1-1 illustrates the Model GS508T switch package contents.

Figure 1-1. Model GS508T Switch Package Contents

Verify that your package contains the following:
• Model GS508T switch
• Rubber footpads for tabletop installation
• The Installation Guide
• Rack mount kit for 19-inch rack installation
• Warranty & Owner Registration Card
• Support Information Card
• Power cord

introduction

1-2

CHAPTER 2: PHYSICAL DESCRIPTION
This chapter describes the hardware features of the NETGEAR Model GS508T
Copper Gigabit Switch.
Front Panel
The front panel of the Model GS508T switch contains the following LEDs that correspond to each network port: Activity (Rx/Tx), FDX/COL (full-duplex/collision), and
10Mbps speed. Each network port has its own link LED (located above each
100/1000 Mbps port).

Figure 2-1. Front Panel of the Model GS508T Switch

physical description

2-1

LEDs
Table 2-1 describes the activity of the LEDs.
Table 2-1. LED Descriptions
Label

Color

Activity

Description

Power

Green

On

Power is supplied to the switch.

Off

Power is disconnected.

On

The port is operating in full-duplex mode.

Off

The port is operating in half-duplex mode.

Yellow

Blinking

Data collisions are occurring on the port. In a full-duplex
environment, there is no collision. In a half-duplex environment,
some collisions are normal.

Activity

Green

Blinking

Packet transmission or reception is occurring on the port.

1000M

Green

On

A valid 1000 Mbps link is established on the port.

Off

A link is not established on the port.

On

A valid 100 Mbps link is established on the port.

Off

A link is not established on the port.

On

A valid 10 Mbps link is established on the port.

Off

A link is not established on the port.

FDX/COL

100M

10M

Green

Green

Green

Rear Panel
As illustrated in Figure 2-2, the rear panel of the Model GS508T switch has fans for cooling and a standard AC power receptacle for the supplied power cord.
Fans

AC power outlet

100-240 VAC 50-60 Hz

Figure 2-2. Rear Panel of the Model GS508T Switch

physical description

2-2

CHAPTER 3: APPLICATIONS
This chapter presents an overview of the levels of service provided by incorporating
the technology of the NETGEAR Model GS508T Copper Gigabit Switch into your
network.
Desktop Switching
Figure 3-1 illustrates the Model GS508T switch, used as a desktop switch to build
a powerful network that enables users to have 1000 Mbps access to a file server.
If a full-duplex adapter card is installed in the server or PC, a 2000 Mbps connection will be provided to each server and PC.

Figure 3-1. Model GS508T Switch Used as a Desktop Switch

applications

3-1

Segment Switching and Bridging from 100 Mbps to 1000 Mbps
The Model GS508T switch, as illustrated in Figure 3-2, connects multiple power
workgroups and servers using high-speed gigabit links. Each power workgroup is
anchored by a NETGEAR Model FS510T switch. Because each copper link can
be up to 100 m long, these workgroups can be located on separate floors or in
different buildings.

Figure 3-2. Model GS508T Switch Used as a Segment Switch

applications

3-2

CHAPTER 4: INSTALLATION
This chapter describes the installation procedures for the NETGEAR Model GS508T
Copper Gigabit Switch.
Preparing the Site
Before you begin installing your switch, prepare the installation site. Make sure your
operating environment meets the operating environment requirements of the equipment listed in Table 4-1.
Table 4-1. Operating Environment Requirements
Characteristic

Requirements

Temperature

Ambient temperature between 0 and 40ºC (32 and 104ºF).
No nearby heat sources such as direct sunlight, warm air exhausts, or heaters.

Operating humidity

Maximum relative humidity of 90%, noncondensing.

Ventilation

Minimum 2 inches (5.08 cm) on all sides for cooling.
Adequate airflow in room or wiring closet.

Operating conditions

At least 6 ft (1.83 m) to nearest source of electromagnetic noise
(such as photocopy machine or arc welder).

Power

Adequate power source within 6 ft (1.83 m).

Installing the Switch on a Flat Surface
To install the switch on a flat surface, be sure to attach the rubber footpads to the
bottom of the switch.

installation

4-1

Installing the Switch in a Rack
Refer to Figure 4-1 when installing the switch in a rack.

100/1000
Mbps

Copper

Gigabit

Switch

Power

Ethern

et
MODEL

GS50
4T

9378FB

Figure 4-1. Attaching Mounting Brackets

Connecting Devices to the Switch
To connect the switch:
1. Connect the devices to the network ports on the switch, using Category 5 (Cat5)
or Category 5e (Cat5e) UTP cable.
Note: Ethernet specifications limit the cable length between your PC or
server and the switch to 100 m.
2. Connect one end of the AC power adapter cable to the power outlet on the
rear panel of the switch and the other end of the power adapter cable to
the wall outlet.
Refer to Figure 4-2 when connecting the switch.

installation

4-2

Key
1000 Mbps
100 Mbps

4POR
T
10/10
0Mbp
sGiga

bit

Fibe
r Swit
ch

Eth
erne
t

MODEL

GS
508
T

9330FB

Figure 4-2. Connecting to the Model GS508T Switch

Verifying Installation
When power has been applied to the switch, verify that:
• The green power LED on the front panel is on.
• The green link LED on each connected port is on.
When the switch is connected and operating, refer to Table 2-1 “LED Descriptions”
for information about the LEDs and their activity.

installation

4-3

CHAPTER 5: TROUBLESHOOTING
This chapter provides information about troubleshooting the NETGEAR Model
GS508T Copper Gigabit Switch. Table 5-1 lists symptoms, causes, and solutions of
possible problems.
Table 5-1. Troubleshooting Information
Symptom

Cause

Solution

Power LED is off.

No power is received
at the switch.

Check the power cord connections for the switch
and the connected device.
Make sure all cables used are correct and comply
with Ethernet specifications.

1000M, 100M or 10M Port connection is
LED is off or
not functioning.
intermittent.

Check the crimp on the connectors and make
sure that the plug is properly inserted and
locked into the port at both the switch and the
connecting device.
Make sure all cables used are correct and comply
with Ethernet specifications. See Appendix C.
Check for a defective adapter card, cable, or port
by testing them in an alternate environment where
all products are functioning.

File transfer is slow
or performance
degradation is
a problem.

Half- or full-duplex
setting on the switch
and the connected
device are not the same.

Make sure the remote link partner is set to
auto negotiate.

A segment or device
is not recognized as
part of the network.

One or more devices
are not properly
connected, or cabling
does not meet
Ethernet guidelines.

Verify that the cabling is correct. Be sure all
cable connectors are securely positioned in the
required ports. Equipment may have been
accidentally disconnected.

FDX/COL LED is
blinking yellow
excessively.

Collisions are
occurring on the
connected segment.

Some collisions are normal when the connection
is operating in half-duplex mode.

Duplex modes are
mismatched.

Recheck the link partner settings.

troubleshooting

5-1

APPENDIX A: TECHNICAL SPECIFICATIONS
This appendix provides technical specifications for the NETGEAR Model GS508T
Copper Gigabit Switch.
Network Protocol and Standards Compatibility
IEEE 802.3ab 1000BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3i 10BASE-T
IEEE 802.3x flow control
Data Rate
1000 Mbps with PAM5 encoding
Performance Specifications
Frame filter rate:

1,480,000 frames/second maximum

Frame forward rate:

1,480,000 frames/second maximum

Network latency (using
64-byte packets):

30 microseconds maximum

Address database size:

8,000 MAC addresses

Addressing:

48-bit MAC address

Queue buffer:

0.5 MB memory per port

Interface
1000BASE-T Gigabit Ethernet RJ-45 connector

technical specifications

A-1

Power Consumption
60 W
Input Voltage (Power Adapter)
100–240 V AC
Physical Specifications
Dimensions:

13.0 x 1.7 x 8.0 in.; 33.0 x 4.3 x 20.7 cm

Weight:

5.3 lb; 2.3 kg

Environmental Specifications
Operating temperature:

0 to 40º C (32 to 104º F)

Operating humidity:

90% maximum relative humidity, noncondensing

Electromagnetic Compliance
CE mark, commercial
FCC Part 15 Class A
VCCI Class A
EN 55022 (CISPR 22) Class A, EN50082-1
C-Tick
Safety Agency Approvals
UL Listed (UL 1950), cUL
TUV Licensed (EN 60 950), IEC 95

technical specifications

A-2

APPENDIX B: CONNECTOR PIN ASSIGNMENTS
This appendix provides information about the RJ-45 plug and the RJ-45 connector
used for the NETGEAR Model GS508T Copper Gigabit Switch.
RJ-45 Plug and RJ-45 Connector
It is important that all 1000 BASE-T certified Category 5 or Category 5e cabling
use RJ-45 plugs.The RJ-45 plug accepts 4-pair UTP or shielded twisted
pair (STP) 100 ohm cable and connects into the RJ-45 connector.
The RJ-45 connector is used to connect stations, hubs, and switches through UTP
cable; it supports 10 Mbps, 100 Mbps, or 1000 Mbps data transmission.
The RJ-45 plug and RJ-45 connector are both illustrated in Figure B-1.
12345678

8

1

Key:
1 to 8 = pin numbers

Figure B-1. RJ-45 Plug and RJ-45 Connector with Built-in LEDs

connector pin assignments

B-1

Table B-1 lists the pin assignments for the 10/100/1000Mbps RJ-45 plug and the RJ-45 connector.
Table B-1. 10/100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments
Pin

Channel

Description

1
2

A

Rx/Tx Data +
Rx/Tx Data -

3
6

B

Rx/Tx Data +
Rx/Tx Data -

4
5

C

Rx/Tx Data +
Rx/Tx Data -

7
8

D

Rx/Tx Data +
Rx/Tx Data -

connector pin assignments

B-2

APPENDIX C: CABLING GUIDELINES
This appendix provides specifications for cables used with the NETGEAR Model
GS508T Copper Gigabit Switch.
Using 1000BASE-T Gigabit Ethernet over Category 5 Cable
Overview
When using the new 1000BASE-T standard, the limitations of cable installations
and the steps necessary to ensure optimum performance must be considered.The
most important components in your cabling system are patch panel connections,
twists of the pairs at connector transition points, the jacket around the twisted pair
cable, bundling of multiple pairs on horizontal runs and punch down blocks. All of
these will affect the performance of 1000BASE-T technology if not correctly
implemented.The following sections are designed to act as a guide to correct
cabling for 1000BASE-T.
Cabling
The 1000BASE-T product is designed to operate over Category 5 cabling, but to
further enhance the operation, the cabling standards have been amended.The latest
standard is Category 5e, which defines a higher level of link performance than is
available with Category 5 cable.
If installing new cable, we recommend using Category 5e cable, since it costs the
same as Category 5 cable and will increase performance. If using the existing
cable, be sure to have the cable plant tested by a professional who can verify that
it meets or exceeds either ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995
Category 5 specifications.
Length
The maximum distance limitation between two pieces of equipment is 100 m, as
per the original Ethernet specification.The end to end link is called the “channel.”
TSB-67 defines the “Basic Link” which is the portion of the link that is part of the
building infrastructure.This excludes patch and equipment cords.The maximum
basic link length is 295 feet (90 m).
cabling guidelines

C-1

Return Loss
Return loss measures the amount of reflected signal energy resulting from impedance
changes in the cabling link.The nature of 1000BASE-T renders this measurement
very important; if too much energy is reflected back on to the receiver, the device will
not perform optimally.
All four pairs of the twisted pair are used by 1000BASE-T, unlike 10BASE-T and
100BASE-TX, which use only two of the four pairs of wires within the Category 5.
It is important to ensure that all wires are tested.
The factors that will affect the return loss are
• the number of transition points, as there is a connection via an RJ-45 to another
connector, a patch panel, or a piece of equipment at each transition point.
• removal of the jacket that surrounds the four pairs of twisted cable. It is highly
recommended that, where RJ-45 connections are made, this is minimized to
1-1/4 inch (32 mm).
• pair untwist of any of the twisted pairs. It is important that this be minimized
to 3/8 inch (10 mm) where RJ-45 connections are made.
• cabling or bundling of multiple Category 5 cable.This is regulated by
ANSI/EIA/TIA-568A-3, and can adversely affect all parameters of the
cabling if not correctly implemented.
Near End Cross Talk (NEXT)
This is a measure of the signal coupling from one wire to another, within a cable
assembly, or among cables within a bundle. NEXT measures the amount of cross-talk
disturbance energy that is detected at the near end of the link—the end at which the
transmitter is located. NEXT measures the amount of energy that is “returned” to
the sender end.The factors that affect NEXT and cross talk are exactly the same as
outlined in the Return Loss section.The cross-talk performance is directly related to
the quality of the cable installation.

cabling guidelines

C-2

Patch Cables
When installing your equipment, replace old patch panel cables that do not meet
Category 5e specifications. As pointed out in the NEXT section, this near end piece
of cable is critical for successful operation.
Conclusions
For optimum performance of your 1000BASE-T product, it is important to
fully qualify your cable installation and ensure it meets or exceeds ANSI/EIA/TIA568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. Install Category
5e cable where possible, including patch panel cables. Minimize transition points,
jacket removal, and untwist lengths. Bundling of cables must be properly installed in
order to meet the requirements in ANSI/EIA/TIA-568A-3.
Fast Ethernet Cable Guidelines
Fast Ethernet uses UTP cable, as specified in the IEEE 802.3u standard for
100BASE-TX.The specification requires Category 5 UTP cable consisting of either
two-pair or four-pair twisted insulated copper conductors bound in a single plastic
sheath. Category 5 cable is certified up to 100 MHz bandwidth. 100BASE-TX
operation uses one pair of wires for transmission and the other pair for receiving
and for collision detection.
When installing Category 5 UTP cabling, use the following guidelines to ensure that
your cables perform to the following specifications:
• Certification
Make sure that your Category 5 UTP cable has completed the Underwriters
Laboratories (UL) or Electronic Testing Laboratories (ETL) certification
process.
• Termination method
To minimize cross-talk noise, maintain the twist ratio of the cable up to the point
of termination; untwist at any RJ-45 plug or patch panel should not exceed
0.5 inch (1.5 cm).

cabling guidelines

C-3

Category 5 Cable
Category 5 distributed cable that meets ANSI/EIA/TIA-568-A building wiring
standards can be a maximum of 328 feet (ft) or 100 meters (m) in length, divided
as follows:
• 20 ft (6 m) between the hub or switch and the patch panel (if used)
• 295 ft (90 m) from the wiring closet to the wall outlet
• 10 ft (3 m) from the wall outlet to the desktop device
The patch panel and other connecting hardware must meet the requirements for
100 Mbps operation (Category 5). Only 0.5 inch (1.5 cm) of untwist in the wire pair
is allowed at any termination point.
Category 5 Cable Specifications
Ensure that the fiber cable is crossed over to guarantee link.
Table C-1 lists the electrical requirements of Category 5 UTP cable.
Table C-1. Electrical Requirements of Category 5 Cable
Specification

Category 5 Cable Requirements

Number of pairs

Four

Impedance

100 Ω ± 15%

Mutual capacitance at 1 KHz

≤ 5.6 nF per 100 m

Maximum attenuation (dB per 100 m, at 20° C)

at 4 MHz: 8.2
at 31 MHz: 11.7
at 100 MHz: 22.0

NEXT loss (dB minimum)

at 16 MHz: 44
at 31 MHz: 39
at 100 MHz: 32

cabling guidelines

C-4

Twisted Pair Cables for 100 BASE-TX
For two devices to communicate, the transmitter of each device must be connected
to the receiver of the other device.The crossover function is usually implemented
internally as part of the circuitry in the device. Computers and workstation adapter
cards are usually media-dependent interface ports, called MDI or uplink ports.
Most repeaters and switch ports are configured as media-dependent interfaces with
built-in crossover ports, called MDI-X or normal ports.
Figure C-1 illustrates straight-through twisted pair cable.

1

1

2

2

Rx

Tx

A

B
3

3

6

6

Tx

Rx

736EA

Key:
A = Uplink or MDI port (as on a PC)
B = Normal or MDI-X port (as on a hub or switch)
1, 2, 3, 6 = Pin numbers

Figure C-1.

Straight-Through Twisted Pair Cable

Figure C-2 illustrates crossover twisted pair cable.

1

1

2

2

Rx

Rx

B

B

Tx

3

3

6

6

Tx

Key:
B = Normal or MDI-X port (as on a hub or switch)
1, 2, 3, 6 = Pin numbers

737EA

Figure C-2. Crossover Twisted Pair Cable
cabling guidelines

C-5

Patch Panels and Cables
If you are using patch panels, make sure that they meet the 100BASE-TX requirements. NETGEAR recommends Category 5e UTP cable for all patch cables and
work area cables to ensure that your UTP patch cable rating meets or exceeds the
distribution cable rating.
To wire patch panels, you need two Category 5e UTP cables with an RJ-45 plug at
each end, as shown in Figure C-3.
1

2

1

87654321
87654321

Key:
1 = RJ-45 plug
2 = Category 5e UTP patch cable

5525.1

Figure C-3. Category 5e UTP Patch Cable with Male RJ-45 Plug at Each End

Note: Flat “silver satin” telephone cable may have the same RJ-45 plug.
However, using telephone cable will result in excessive collisions and cause the
attached port to be partitioned or disconnected from the network.

cabling guidelines

C-6

cabling guidelines

C-7

R

NETGEAR, Inc.
4500 Great America Parkway
Santa Clara, CA 95054 USA
Phone: 1-888-NETGEAR
www.NETGEAR.com

M

1

-

G

S

5

0

8

T

N

A

-

0

March 2001



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2001:03:07 14:05:28
Producer                        : Acrobat Distiller 4.0 for Macintosh
Creator                         : QuarkXPressþ 4.0.3: LaserWriter 8 TA-8.6
Author                          : G3
Title                           : GS508T.Manual-0306
Modify Date                     : 2001:03:07 14:06:14+08:00
Page Count                      : 30
EXIF Metadata provided by EXIF.tools

Navigation menu