New focus Lighting and Power Technology PP100FM XPower Pocket Inv FM User Manual XPower pocket inv FM

New focus Lighting & Power Technology (Shanghai) Co., Ltd. XPower Pocket Inv FM XPower pocket inv FM

User Guide

XPower_pocket_inv_FM.book
Page
ii
Tuesday,
May
22,
2007
9:00
AM
Caution:
This device complies with part15 of the FCC Rules.
Operation is subject to the following two conditions :(1) this device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Note:
THE MANUFACTURER IS NOT RESPONSIBLE FOR
ANY RADIO OR TV INTERFERENCE CAUSED BY
UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.
SUCH MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this
device must accept any interference, including
interference that may cause undesired operation of
the device.
XPower_pocket_inv_FM.book
Page
i
Tuesday,
May
22,
2007
9:00
AM
Abou
t
Xantre
x
Xantrex
Technology
Inc.
is
a
world-leading
supplier
of
advanced
power
electronics
and
controls
with
products
from
50
watt
mobile
units
to
1
MW
utility-scale
systems
for
wind,
solar,
batteries,
fuel
cells,
microturbines,
and
backup
power
applications
in
both
grid-
connected
and
stand-alone
systems.
Xantrex
products
include
inverters,
battery
chargers,
programmable
power
supplies,
and
variable
speed
drives
that
convert,
supply,
control,
clean,
and
distribute
electrical
power.
T
r
ademarks
XPower
by
Xantrex
is
a
trademark
of
Xantrex
International.
Xantrex
is
a
registered
trademark
of
Xantrex
International.
Other
trademarks,
registered
trademarks,
and
product
names
are
the
property
of
their
respective
owners
and
are
used
herein
for
identification
purposes
only.
Notice
of
Co
pyrig
h
t
XPower
Pocket
Inverter
FM
Owner’s
Guide
©
May
2007
Xantrex
International.
All
rights
reserved.
Exclusion
for
Docume
ntation
Unless
specifically
agreed
to
in
writing,
Xantrex
Technology
Inc.
(“Xantrex”)
(
A
)
MAKES
NO
WARRANTY
AS
TO
THE
ACCURACY
,
SUFFICIENCY OR
SUITABILITY
OF
ANY
TECHNICAL
OR
OTHER
INFORMATION
PROVIDED
IN
ITS
MANUALS
OR
OTHER
DOCUMENTATION
.
XPower_pocket_inv_FM.book
Page
ii
Tuesday,
May
22,
2007
9:00
AM
(
B
)
ASSUMES
NO
RESPONSIBILITY
OR
LIABILITY
FOR
LOSSES
,
DAMAGES
,
COSTS
OR
EXPENSES
,
WHETHER
SPECIAL
,
DIRECT
,
INDIRECT
,
CONSEQUENTIAL
OR
INCIDENTAL
,
WHICH
MIGHT
ARISE
OUT
OF
THE
USE
OF
SUCH
INFORMATION
.
T
HE
USE
OF
ANY
SUCH
INFORMATION
WILL
BE
ENTIRELY
AT
THE
USER
S
RISK
;
AND
(
C
)
REMINDS
YOU
THAT
IF
THIS
MANUAL
IS
IN
ANY
LANGUAGE
OTHER
THAN
E
NGLISH
,
ALTHOUGH
STEPS
HAVE
BEEN
TAKEN
TO
MAINTAIN
THE
ACCURACY
OF
THE
TRANSLATION
,
THE
ACCURACY
CANNOT
BE
GUARANTEED
.
A
PPROVED
X
ANTREX
CONTENT
IS
CONTAINED
WITH
THE
E
NGLISH
LANGUAGE
VERSION
WHICH
IS
POSTED
AT
WWW
.
XANTREX
.
COM
.
Date
an
d
Revision
May
2007
Revision
A
Pr
odu
c
t
Num
b
er
813-0281-01
P
a
rt
Nu
mber
975-0361-01-01
Con
t
act
Information
Telephone:
1
360-925-5059
Fax:
1
360-925-5143
Web:
www.xantrex.com/support
XPower_pocket_inv_FM.book
Page
iii
Tuesday,
May
22,
2007
9:00
AM
Contents
1.
Introduction
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
2.
Important
Safety
Information
.
.
.
.
.
.
.
.
.
.
.
.
.
3
Warnings
and
Cautions
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
Additional
Safety
Guidelines
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7
3.
Safety
Features
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
8
4.
Inverter
Features
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
5.
Using
the
Inverter
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10
Using
the
DC
Cable
with
Cigarette
Lighter
Plug
.
10
6.
Inverter
Operation.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
12
Operating
Guidelines
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
12
Battery
Operating
Time
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
14
Interference
with
Electronic
Equipment
.
.
.
.
.
.
.
.
14
7.
Using
the
FM
Transmitter
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
16
Features
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
17
Operation
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
17
8.
Troubleshooting
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
19
Replacing
the
Fuse
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
22
iii
XPower_pocket_inv_FM.book
Page
iv
Tuesday,
May
22,
2007
9:00
AM
9.
Specifications
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
AC
Power
Output
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
DC
Power
Specifications
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
Physical
Specifications
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
24
10.
Warranty
and
Return
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
25
iv
XPower_pocket_inv_FM.book
Page
1
Tuesday,
May
22,
2007
9:00
AM
1
I
ntr
oduction
Thank
you
for
purchasing
the
XPower
Pocket
Inverter
FM.
The
XPower
inverter
is
part
of
a
family
of
advanced
high-performance
power
inverters
from
Xantrex,
the
leader
in
high-frequency
inverter
design.
Connected
to
the
12
volt
outlet
in
your
vehicle,
the
XPower
inverter
efficiently
and
reliably
powers
a wide
variety
of
loads
through
the
AC
outlet.
With
a built-in
FM
transmitter,
you
can
plug
an
iPod
and other
audio
devices
through
the
audio
input
port
and listen
to
the
sound
via
your
vehicle’s
factory-installed
or
third-party
stereo/radio
tuner.
The
XPower
inverter
uses
reliable
solid
state
power
electronics
for
years
of
safe,
trouble-free
operation and
includes
automatic
safety
monitoring
circuitry
to
protect
it,
and
your
battery,
from
inadvertent
overload
conditions.
Read
this
guide
before
connecting
or
using
the
XPower
inverter,
and
save
it
for
future
reference.
The
main
topics
in
the
guide
are:
Safety
information
(page
3)
XPower
inverter
features
(page
9)
1
XPower_pocket_inv_FM.book
Page
2
Tuesday,
May
22,
2007
9:00
AM
Instructions
for
connecting
the
inverter
(page
10)
Operating
guidelines
(page
12)
Operating
the
FM
Transmitter
(page
16)
Troubleshooting
information
(page
19)
Specifications
(page
23)
Warranty
and
service
information
(page
25)
2
XPower_pocket_inv_FM.book
Page
3
Tuesday,
May
22,
2007
9:00
AM
2
Important
Safety
Information
Misusing
or
incorrectly
connecting
the
XPower
inverter
may
damage
the
equipment
or
create
hazardous
conditions
for
users.
Read
the
following
safety
instructions
and
pay
special
attention
to
all
Caution
and
Warning
statements
in
the
guide.
Warnings
identify
conditions
that
may
result
in
personal
injury
or
loss
of
life.
Cautions
identify
conditions
or
practices
that
may
damage
the
unit
or
other
equipment.
W
a
rnings
and
Cautions
WA
R
N
I
N
G
Keep children away from the XPower inverter. The
inverter generates the same potentially lethal AC
power as a normal household wall outlet. Treat the
outlet with respect!
3
XPower_pocket_inv_FM.book
Page
4
Tuesday,
May
22,
2007
9:00
AM
WA
R
N
I
N
G
The XPower inverter housing may become
uncomfortably warm, reaching 140° F (60° C) under
extended high power operation. During operation,
keep it away from materials that may be affected by
high temperatures.
WA
R
N
I
N
G
Do not use the XPower inverter in the presence of
flammable fumes or gases, such as in the bilge of a
gasoline powered boat, or near propane tanks. Do
not use the XPower inverter in an enclosure
containing automotive-type, lead-acid batteries.
These batteries, unlike sealed batteries, vent
explosive hydrogen gas, which can be ignited by
sparks from electrical connections.
4
XPower_pocket_inv_FM.book
Page
5
Tuesday,
May
22,
2007
9:00
AM
W
A
RNING:
Shock
hazar
d
Use caution when inserting an AC plug into the
three-prong AC outlet. The prongs of an AC plug
can become bent from misuse. If an AC plug is
improperly inserted into the AC outlet, a bent prong
can slip outside the inverter and become a shock
hazard.
W
A
RNING:
Shock
hazar
d
Grip the inverter carefully when inserting or
removing an AC plug. Keep your fingers clear of
the AC outlet. Ensure that your fingers do not
contact the prongs of an AC plug when the plug is
partially inside the inverter.
5
XPower_pocket_inv_FM.book
Page
6
Tuesday,
May
22,
2007
9:00
AM
CAUT
ION
:
Ou
tp
ut
non
-
sinu
soidal
Some chargers for small nickel-cadmium batteries
can be damaged if connected to the XPower inverter.
Do not use the inverter with the following
appliances:
Small battery-operated appliances like
rechargeable flashlights, some rechargeable
shavers, and night lights that are plugged
directly into an AC receptacle to recharge.
Battery chargers used in hand power tools.
These chargers display a warning label stating
that dangerous voltages are present at the
charger battery terminals.
CAUT
ION
Do not connect live AC power to the XPower
inverter’s AC outlets. This will damage the inverter,
and the damage is not covered by warranty.
Do not connect any AC load that has its neutral
conductor connected to ground to the XPower
inverter.
6
XPower_pocket_inv_FM.book
Page
7
Tuesday,
May
22,
2007
9:00
AM
Additional
Safety
Guidelines
Do
not
insert
foreign
objects
in
the
XPower
inverter
outlets
or
other
openings.
Never
connect
the
inverter
to
power
utility
AC
distribution
wiring.
Do
not
use
the
XPower
inverter
in
temperatures
over
100°
F
(40°
C).
Do
not
expose
the
XPower
inverter
to
water,
rain,
snow,
or
spray.
Failure
to
follow
these
safety
guidelines
may
cause
personal
injury
and/or
damage
to
the
XPower
inverter. It
may
also
void
your
product
warranty.
7
XPower_pocket_inv_FM.book
Page
8
Tuesday,
May
22,
2007
9:00
AM
3
Safety
F
e
atur
es
These
advanced
safety
features
are
built
into
the
XPower
inverter:
Electronic
overload
protection
with
automatic
shutdown
User-replaceable
8
A
Slow-blow
fuse
Low
battery
voltage
shutdown
High-input
voltage
protection
with
automatic
shutdown
Overheat
protection
with
automatic
shutdown
Output
short
circuit
protection.
8
XPower_pocket_inv_FM.book
Page
9
Tuesday,
May
22,
2007
9:00
AM
4
I
nverter
F
e
atur
es
FM
transmitter
channel
tuner
XPower
Pocket
Inverter
FM
with
a
built-in
FM
Transmitter
Ventilation
openings
Audio
input
port
DC
cable
port
power/fault
light
indicator
AC
outlet
DC
Cable
12
volt
(lighter
socket)
cable
Part
#:
808-7141
Replaceable
fuse
(see
page
21)
Figur
e
1
F
e
at
ures
and
Access
ories
9
XPower_pocket_inv_FM.book
Page
10
Tuesday,
May
22,
2007
9:00
AM
5
Using
the
Inverter
Through
its
AC
outlet,
the
XPower
inverter
is
capable
of
powering
most
120
V
AC
products
that
use
100
W
or
less.
The
XPower
inverter’s
AC
output
waveform,
called
“modified
sine
wave,”
is
designed
to
function
similarly
to
the
sine
wave
shape
of
utility
power.
Using
the
DC
Cable
with
Cigar
ette
Lighter
Plug
Due
to
the
limitations
of
12
V
outlets
in
vehicles
or
boats,
the
XPower
inverter
should
only
be
used
to
supply
AC
power
to
products
that
require
100
W
(about
0.8
A)
or
less.
1.
Plug
the
DC
cable
(Xantrex
part
number:
808-7141)
into
the
DC
cable
port
on
the
XPower
inverter.
Observe
correct
polarity.
See
Figure
2.
10
XPower_pocket_inv_FM.book
Page
11
Tuesday,
May
22,
2007
9:00
AM
CA
UTION:
Rever
s
e
polarity
damage
When plugging in the DC cable, ensure that the plug
aligns with the DC cable port. Failure to do so will
result in reverse polarity and a blown fuse.
2.
Insert
the
cigarette
lighter
plug
into
the
12
V
outlet.
3.
Plug
the
device
you
want
to
operate
into
the
XPower
inverter.
See
“Inverter
Operation”
on
page
12.
4.
When
the
inverter
is
not
in
use,
unplug
it
from
the
12
V
outlet
to
prevent
slight
discharge
of
the
battery.
Ensure
correct
alignment
Figur
e
2
Conne
cting
the
Inverter
and
DC
Cable
11
XPower_pocket_inv_FM.book
Page
12
Tuesday,
May
22,
2007
9:00
AM
6
I
nver
ter
O
p
eration
1.
When
properly
connected
to
a
12
V
outlet
the
power/fault
light
indicator
will
glow
green,
indicating
the
inverter
is
ready.
2.
Plug
the
product(s)
you
want
to
operate
into
the
AC
outlet
and
switch
them
on
(if
necessary).
Oper
ating
Guidelines
As
the
battery
is
used,
its
voltage
begins
to
fall.
When
the
XPower
inverter
senses
that
the
voltage
at
its
DC
input
has
dropped
to
10.5
V,
the
inverter
automatically
shuts
down
and
the
light
glows
red,
indicating
a
fault.
This
prevents
the
battery
from
being
damaged.
Turn
off
any
devices
that
the
XPower
inverter
is
powering.
Important:
Vehicle
batteries
are
designed
to
provide
brief
periods
of
very
high
current
needed
for
engine
starting.
They
are
not
intended
for
constant
deep
discharge.
Regularly
operating
the
XPower
inverter
from
a
vehicle
battery
until
low-voltage
shutdown
occurs
will
shorten
the
life
of
the
battery.
12
XPower_pocket_inv_FM.book
Page
13
Tuesday,
May
22,
2007
9:00
AM
If
an
AC
product
rated
higher
than
100
W
is
plugged
into
the
XPower
inverter,
the
inverter
will
shut
down.
The
red
fault
light
comes
on.
If
the
XPower
inverter
exceeds
a
safe
operating
temperature,
due
to
insufficient
ventilation
or
a
high-temperature
environment,
it
automatically
shuts
down.
The
red
fault
light
comes
on.
Should
a
defective
battery
charging
system
cause
the
battery
voltage
to
rise
to
dangerously
high
levels,
the
XPower
inverter
automatically
shuts
down.
The
red
fault
light
comes
on.
CAUT
ION
Although the XPower inverter incorporates
protection against over-voltage, it may still be
damaged if the input voltage exceeds 16 V.
In
the
event
of
an
overload,
low
battery
voltage
or
overheating,
the
XPower
inverter
automatically
shuts
down.
13
XPower_pocket_inv_FM.book
Page
14
Tuesday,
May
22,
2007
9:00
AM
Battery
Oper
ating
Time
Operating
time
will
vary
depending
on
the
charge
level
of
the
battery,
its
capacity
and
the
power
level
drawn
by
the
particular
AC
load.
With
a
typical
vehicle
battery
and
an
80
W
load,
an
operating
time
of
4
to
5
hours
or
more
can
be
expected.
When
using
a
vehicle
battery
as
a
power
source,
it
is
strongly
recommended
to
start
the
vehicle
every
hour
or
two
to
recharge
the
battery
before
its
capacity
drops
too
low.
The
XPower
inverter
can
operate
while
the
engine
is
running,
but
the
normal
voltage
drop
that
occurs
during
starting
of
the
engine
may
trigger
the
inverters
low
voltage
shutdown
feature.
Interfer
ence
with
Electr
onic
Equipment
Generally,
most
AC
products
operate
with
the
XPower
inverter
just
as
they
would
with
household
AC
power.
Below
is
information
concerning
two
possible
exceptions.
14
XPower_pocket_inv_FM.book
Page
15
Tuesday,
May
22,
2007
9:00
AM
Buzzing
sound
in
audio
systems
and
r
a
dios
Some
inexpensive
stereo
systems
and
AM-FM
radios
have
inadequate
internal
power
supply
filtering
and
“buzz”
slightly
when
powered
by
the
XPower
inverter.
Generally,
the
only
solution
is
an
audio
product
with
a
higher
quality
filter.
T
e
le
v
i
si
on
in
te
rfe
r
e
n
c
e
The
XPower
inverter
is
shielded
to
minimize
its
interference
with
TV
signals.
However,
with
weak
TV
signals
interference
may
be
visible
in
the
form
of
lines
scrolling
across
the
screen.
The
following
should
minimize
or
eliminate
the
problem:
Increase
the
distance
between
the
XPower
inverter
and
the
TV,
antenna
and
cables.
Adjust
the
orientation
of
the
XPower
inverter,
television,
antenna
and
cables.
Maximize
TV
signal
strength
by
using
a
better
antenna
and
use
shielded
antenna
cable
where
possible.
15
XPower_pocket_inv_FM.book
Page
16
Tuesday,
May
22,
2007
9:00
AM
7
Using
the
FM
T
r
ansmitter
XPower
inverter
ventilation
slots
power/fault
light
indicator
179.9
channel
DOWN
button
channel
UP
button
channel
LED
display
Figur
e
3
Channe
l
T
uner
16
XPower_pocket_inv_FM.book
Page
17
Tuesday,
May
22,
2007
9:00
AM
Fe
a
t
u
re
s
Channel
tuner
covers
complete
North
American
FM
channels
Bright
LED
displays
FM
channel
frequency
UP
and
DOWN
buttons
provide
easy
tuning
Last
selected
channel
memorization
for
quick
setup
Oper
ation
1.
Plug
the
DC
cable
into
the
DC
cable
port
on
the
XPower
inverter.
Observe
correct
polarity.
2.
Insert
the
cigarette
lighter
plug
into
the
12
V
outlet.
3.
Insert
the
male
plug
of
a
standard
3.5mm
stereo
cable
(not
supplied
by
Xantrex)
into
the
audio
device’s
headphone
jack.
4.
Insert
the
other
male
plug
of
the
stereo
cable
into
the
XPower
inverter’s
audio
input
port.
The
channel
LED
display
lights
up
and
shows
the
last
selected
channel
frequency
5.
Tune
the
vehicle’s
FM
radio
to
a
non-
broadcasting
FM
channel
while
on
ground
level.
17
XPower_pocket_inv_FM.book
Page
18
Tuesday,
May
22,
2007
9:00
AM
Important:
Certain
areas,
especially
in
underground
parking
lots,
generally
obscure
FM
channel
reception.
When
you
select
an
FM
channel
while
underground,
the
channel
may
in
fact
be
broadcasting
when
the
vehicle
is
on
ground
level.
6.
Match
the
XPower
inverter’s
FM
transmitter
channel
tuner
frequency
to
the
vehicle’s
FM
channel
frequency.
7.
Turn
on
and
start
operating
the
audio
device.
Important:
It
may
become
necessary
to
adjust
the
volume
of
the
audio
device
to
higher
levels
if
the
sound
in
the
vehicle
remains
faint
even
after
adjusting
its
stereo/radio
tuners
volume.
18
XPower_pocket_inv_FM.book
Page
19
Tuesday,
May
22,
2007
9:00
AM
8
T
r
o
ubleshooting
PROBLE
M
:
A
C
pr
o
duct
w
ill
n
o
t
op
er
ate,
no
in
verte
r
lig
hts
are
ON
.
P
o
ss
ible
c
a
use
R
e
medy
Loose connections. Check connections.
8 A fuse in the DC
charging cable has
blown.
Vehicle’s battery may
be defective.
Replace fuse (see page 21).
Check the battery and replace if
required.
19
XPower_pocket_inv_FM.book
Page
20
Tuesday,
May
22,
2007
9:00
AM
PROBLE
M
:
A
C
pr
o
duct
w
ill
n
o
t
op
er
ate,
re
d
FAULT
lig
ht
ON
.
P
o
ss
ible
c
a
use
R
e
medy
AC product(s)
connected are rated at
more than the
inverter’s continuous
power rating;
overload shutdown
has occurred.
Use a product with a power
rating less than the inverter’s
continuous power rating.
AC product is rated
less than the
inverter’s continuous
power rating; high
starting surge has
caused overload
shutdown.
Product exceeds inverters
surge capability. Use a product
with starting surge power
within the inverters capability.
20
XPower_pocket_inv_FM.book
Page
21
Tuesday,
May
22,
2007
9:00
AM
P
o
ss
ible
c
a
use
R
e
medy
The inverter has
overheated due to
poor ventilation and
has shut down.
Unplug inverter from DC
socket and allow to cool for 15
minutes. Remove objects
covering unit. Move the
inverter to a cooler place.
Reduce load if continuous
operation is required. Restart.
PROBLE
M
:
M
easu
r
ed
in
verte
r
o
u
tpu
t
is
too
lo
w
.
P
o
ss
ible
c
a
use
R
e
medy
Standard “average-
reading” AC
voltmeter used to
measure output
voltage, resulting in
an apparent reading 5
to 15 V too low.
Inverters “modified sine
wave” output requires “true
RMS” voltmeter for accurate
measurements.
Vehicle’s battery
voltage is too low. Run the vehicle to recharge
battery.
21
XPower_pocket_inv_FM.book
Page
22
Tuesday,
May
22,
2007
9:00
AM
Replacing
the
Fuse
The
lighter
cable
for
the
XPower
inverter
has
a
replaceable
8
A
Slow-blow
fuse.
Remove
the
blown
fuse
from
the
plug
by
gently
unscrewing
the
tip
of
the
lighter
plug,
and
replace
the
fuse
with
a
Littelfuse
Slo-
Blo
®
fuse,
Littelfuse
catalog
number
313
008.
22
XPower_pocket_inv_FM.book
Page
23
Tuesday,
May
22,
2007
9:00
AM
9
S
pecifications
Specifications
are
subject
to
change
without
notice.
A
C
P
o
wer
Output
AC
output
voltage
120
V
AC
(nominal)
Continuous
AC
output
power
80
W
Peak
AC
output
power
100
W
Maximum
AC
output
surge
power
160
W
AC
output
frequency
60
±
1
Hz
AC
output
waveform
Modified
sine
wave
DC
P
o
wer
Specifications
DC
input
voltage
range
10.5–15.5
VDC
Vehicle
battery
drain
with
no
AC
load 0.4
A
(at
12
V
input)
Efficiency
(maximum)
85%
Low
battery
shutdown
point
(nominal)
10.5
V
High
battery
shutdown
point
(nominal)
15.5
V
23
XPower_pocket_inv_FM.book
Page
24
Tuesday,
May
22,
2007
9:00
AM
Physical
Specifications
Ambient
operating
temperature
range 0
°C–40
°C
(32
°F–104
°F)
Dimensions
(L
×
W
×
H)
5
1/8
×
3
3/16
×
23/32
in.
(130
×
81
×
18
mm
)
Weight
0.5
lb.
(227
g)
24
XPower_pocket_inv_FM.book
Page
25
Tuesday,
May
22,
2007
9:00
AM
10
W
arr
anty
and
Return
Wa
rra
n
t
y
What does this warranty cover? This Limited
Warranty is provided by Xantrex Technology, Inc.
("Xantrex") and covers defects in workmanship and
materials in your
XPower inverter. This warranty period lasts for 1 year from
the date of purchase at the point of sale to you, the original
end user customer. You require proof of purchase to make
warranty claims.
What will Xantrex do? Xantrex will, at its option, repair
or replace the defective product free of charge, provided that
you notify Xantrex of the product defect within the
Warranty Period, and provided that Xantrex through
inspection establishes the existence of such a defect and that
it is covered by this Limited Warranty.
Xantrex will, at its option, use new and/or reconditioned
parts in performing warranty repair and building
replacement products. Xantrex reserves the right to use parts
or products of original or improved design in the repair or
replacement. If Xantrex repairs or replaces a product, its
warranty continues for the remaining portion of the original
Warranty Period or 90 days from the date of the return
25
XPower_pocket_inv_FM.book
Page
26
Tuesday,
May
22,
2007
9:00
AM
shipment to the customer, whichever is greater. All replaced
products and all parts removed from repaired products
become the property of Xantrex.
Xantrex covers both parts and labor necessary to repair the
product, and return shipment to the customer via a Xantrex-
selected non-expedited surface freight within the contiguous
United States and Canada. Alaska and Hawaii are excluded.
Contact Xantrex Customer Service for details on freight
policy for return shipments outside of the contiguous United
States and Canada.
How do you get service?
If your product requires troubleshooting or warranty
service, contact your dealer.
If you are unable to contact your dealer, or the dealer is
unable to provide service, contact Xantrex directly at:
Telephone: 1 360-925-5059
Fax: 1 360-925-5143
Website: www.xantrex.com/support
Direct returns may be performed according to the Xantrex
Return Material Authorization Policy described in your
product manual. For some products, Xantrex maintains a
network of regional Authorized Service Centers. Call
Xantrex or check our website to see if your product can be
repaired at one of these facilities.
26
XPower_pocket_inv_FM.book
Page
27
Tuesday,
May
22,
2007
9:00
AM
What proof of purchase is required? In any warranty
claim, dated proof of purchase must accompany the product
and the product must not have been disassembled or
modified without prior written authorization by Xantrex.
Proof of purchase may be in any one of the following forms:
The dated purchase receipt from the original purchase
of the product at point of sale to the end user, or
The dated dealer invoice or purchase receipt showing
original equipment manufacturer (OEM) status, or
The dated invoice or purchase receipt showing the
product exchanged under warranty
27
XPower_pocket_inv_FM.book
Page
28
Tuesday,
May
22,
2007
9:00
AM
What does this warranty not cover? This Limited
Warranty does not cover normal wear and tear of the product
or costs related to the removal, installation, or
troubleshooting of the customer's electrical systems. This
warranty does not apply to and Xantrex will not be
responsible for any defect in or damage to:
a) the product if it has been misused, neglected, improp-
erly installed, physically damaged or altered, either
internally or externally, or damaged from improper use
or use in an unsuitable environment;
b) the product if it has been subjected to fire, water,
generalized corrosion, biological infestations, or input
voltage that creates operating conditions beyond the
maximum or minimum limits listed in the Xantrex
product specifications including high input voltage
from generators and lightning strikes;
c) the product if repairs have been done to it other than by
Xantrex or its authorized service centers (hereafter
"ASCs");
d) the product if it is used as a component part of a prod-
uct expressly warranted by another manufacturer;
e) the product if its original identification (trade-mark,
serial number) markings have been defaced, altered, or
removed.
28
XPower_pocket_inv_FM.book
Page
29
Tuesday,
May
22,
2007
9:00
AM
Dis
c
laimer
Pr
oduct
THIS
LIMITED
WARRANTY
IS
THE
SOLE
AND
EXCLUSIVE
WARRANTY
PROVIDED
BY
XANTREX
IN
CONNECTION
WITH
YOUR
XANTREX
PRODUCT
AND
IS,
WHERE
PERMITTED
BY
LAW,
IN
LIEU
OF
ALL
OTHER
WARRANTIES,
CONDITIONS, GUARANTEES,
REPRESENTATIONS,
OBLIGATIONS
AND LIABILITIES,
EXPRESS
OR
IMPLIED,
STATUTORY
OR
OTHERWISE IN
CONNECTION
WITH
THE
PRODUCT,
HOWEVER
ARISING
(WHETHER
BY
CONTRACT,
TORT,
NEGLIGENCE,
PRINCIPLES
OF
MANUFACTURER'S
LIABILITY,
OPERATION
OF
LAW,
CONDUCT,
STATEMENT
OR
OTHERWISE),
INCLUDING
WITHOUT RESTRICTION
ANY
IMPLIED
WARRANTY
OR
CONDITION
OF QUALITY,
MERCHANTABILITY
OR
FITNESS
FOR
A
PARTICULAR PURPOSE.
ANY
IMPLIED
WARRANTY
OF
MERCHANTABILITY
OR FITNESS
FOR
A
PARTICULAR
PURPOSE
TO
THE
EXTENT
REQUIRED
UNDER
APPLICABLE
LAW
TO
APPLY
TO
THE
PRODUCT
SHALL
BE
LIMITED
IN
DURATION
TO
THE
PERIOD
STIPULATED
UNDER
THIS
LIMITED
WARRANTY.
IN
NO
EVENT
WILL
XANTREX
BE
LIABLE
FOR
ANY
SPECIAL,
INDIRECT,
INCIDENTAL
OR
CONSEQUENTIAL
DAMAGES,
LOSSES,
COSTS
OR
EXPENSES
HOWEVER
ARISING
WHETHER
IN
CONTRACT
OR
TORT
INCLUDING
WITHOUT
RESTRICTION
ANY
ECONOMIC
LOSSES
OF
ANY
KIND,
ANY
LOSS
OR
DAMAGE
TO
PROPERTY,
ANY
PERSONAL
INJURY,
ANY
DAMAGE
OR
INJURY
ARISING
FROM
OR
AS
A
RESULT
OF
MISUSE
OR
ABUSE,
OR
THE
INCORRECT
INSTALLATION,
INTEGRATION
OR
OPERATION
OF
THE
PRODUCT.
29
XPower_pocket_inv_FM.book
Page
30
Tuesday,
May
22,
2007
9:00
AM
Exclusions
If this product is a consumer product, federal law does not
allow an exclusion of implied warranties. To the extent you
are entitled to implied warranties under federal law, to the
extent permitted by applicable law they are limited to the
duration of this Limited Warranty. Some states and
provinces do not allow limitations or exclusions on implied
warranties or on the duration of an implied warranty or on
the limitation or exclusion of incidental or consequential
damages, so the above limitation(s) or exclusion(s) may not
apply to you. This Limited Warranty gives you specific
legal rights. You may have other rights which may vary
from state to state or province to province.
W
ar
ning:
Li
mi
ta
ti
ons
On
Use
Please refer to your product manual for limitations on uses
of the product.
SPECIFICALLY,
PLEASE
NOTE
THAT
THE
XP
OWER
INVERTER
SHOULD
NOT
BE
USED
IN
CONNECTION
WITH
LIFE
SUPPORT
SYSTEMS
OR
OTHER
MEDICAL
EQUIPMENT
OR
DEVICES.
WITHOUT
LIMITING
THE
GENERALITY
OF
THE
FOREGOING,
XANTREX
MAKES
NO
REPRESENTATIONS
OR
WARRANTIES
REGARDING
THE
USE
OF
THE
XANTREX
XP
OWER
INVERTER
IN
CONNECTION
WITH
LIFE
SUPPORT
SYSTEMS
OR
OTHER
MEDICAL
EQUIPMENT
OR
DEVICES.
30
XPower_pocket_inv_FM.book
Page
31
Tuesday,
May
22,
2007
9:00
AM
Please note that the XPower inverter is not intended for use
as an uninterruptible power supply and Xantrex makes no
warranty or representation in connection with any use of the
product for such purposes.
Return
Material
Authorization
P
o
licy
Before returning a product directly to Xantrex you must
obtain a Return Material Authorization (RMA) number and
the correct factory "Ship To" address. Products must also be
shipped prepaid. Product shipments will be refused and
returned at your expense if they are unauthorized, returned
without an RMA number clearly marked on the outside of
the shipping box, if they are shipped collect, or if they are
shipped to the wrong location.
When you contact Xantrex to obtain service, please have
your instruction manual ready for reference and be prepared
to supply:
The serial number of your product
Information about the installation and use of the unit
Information about the failure and/or reason for the
return
A copy of your dated proof of purchase
31
XPower_pocket_inv_FM.book
Page
32
Tuesday,
May
22,
2007
9:00
AM
Return
Pr
oce
d
ur
e
1. Package the unit safely, preferably using the original
box and packing materials. Please ensure that your
product is shipped fully insured in the original
packaging or equivalent. This warranty will not apply
where the product is damaged due to improper
packaging.
2. Include the following:
The RMA number supplied by Xantrex
Technology, Inc. clearly marked on the outside of
the box.
A return address where the unit can be shipped.
Post office boxes are not acceptable.
A contact telephone number where you can be
reached during work hours.
A brief description of the problem.
3. Ship the unit prepaid to the address provided by your
Xantrex customer service representative.
If you are returning a product from outside of the USA
or Canada In addition to the above, you MUST include
return freight funds and are fully responsible for all
documents, duties, tariffs, and deposits.
32
XPower_pocket_inv_FM.book
Page
33
Tuesday,
May
22,
2007
9:00
AM
If you are returning a product to a Xantrex Authorized
Service Center (ASC) A Xantrex return material
authorization (RMA) number is not required. However, you
must contact the ASC prior to returning the product or
presenting the unit to verify any return procedures that may
apply to that particular facility.
Out
of
W
arr
anty
Service
If the warranty period for your XPower inverter has expired,
if the unit was damaged by misuse or incorrect installation, if
other conditions of the warranty have not been met, or if no
dated proof of purchase is available, your inverter may be
serviced or replaced for a flat fee.
To return your XPower inverter for out of warranty service,
contact Xantrex Customer Service for a Return Material
Authorization (RMA) number and follow the other steps
outlined in “Return Procedure” on page 32.
Payment options such as credit card or money order will be
explained by the Customer Service Representative. In cases
where the minimum flat fee does not apply, as with
incomplete units or units with excessive damage, an
additional fee will be charged. If applicable, you will be
contacted by Customer Service once your unit has been
received.
33
XPower_pocket_inv_FM.book
Page
34
Tuesday,
May
22,
2007
9:00
AM
34

Navigation menu