NexusData GA0001 DSSS Gas Meter Transmitter User Manual intallation manual

NexusData Ltd. DSSS Gas Meter Transmitter intallation manual

intallation manual

Download: NexusData GA0001 DSSS Gas Meter Transmitter User Manual intallation manual
Mirror Download [FCC.gov]NexusData GA0001 DSSS Gas Meter Transmitter User Manual intallation manual
Document ID133887
Application ID2Lt4qvnfA9Tnbti72bk0nA==
Document Descriptionintallation manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize41.71kB (521334 bits)
Date Submitted2001-01-24 00:00:00
Date Available2001-01-23 00:00:00
Creation Date2001-01-18 08:34:06
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2001-01-18 08:37:15
Document TitleNexus data- installation and program initialization manual
Document CreatorMicrosoft Word 8.0
Document Author: Eli E

NexusData Transmitter Installation and Initialization
General
In order to comply with FCC RF Exposure requirements, the AMR unit
must be installed in such a way that there is a 2m (6’ 8”) separation
distance between it and all persons during normal operation.
Assembly
1. Disassemble old index cover.
2. Disassemble the index from the meter.
3. Attach the Transmitter to the meter, matching its shaft to the meter
shaft. Use four 56m”m screws to secure the Transmitter in its position.
Verify that the shaft enables some free rotation, indicating that the
shafts are properly aligned.
4. Assemble the index on the Transmitter, using two 10m”m screws,
matching its shaft to the Transmitter shaft.
5. Attach new index cover to the Transmitter, using four 20m”m screws.
6. Initialize the AMR unit using the Mint handheld terminal/programmer:
6.1. Press 1 from the General Menu below, for WO (work order) by
route to initialize the next AMR unit.
1. WO by route
2. Add WO
3. Read TX
4. Program TX
→
Key in '1’
6.2. Browse work order (< and > keys) and verify the details. Then
proceed with the ENTER key.
Example:
WO: 1/ 36 to do
Loc: Garage/Left
Address: 1678 N
Piedmont Rd, Atlanta,
GA 30303
→
Key ENTER
6.3. Verify that meter parameters (meter number, number of dials,
index drive and index pressure) presented are correct. Then select
‘4’ (CCF Reading) and enter the reading appearing on the index.
Example
Meter: 111222333
1. No. of Dials: 4
2. Index Drive: 1
3. Index Pressure: LP
4. CCF Reading: _
→
Key ‘4’
Enter Reading as
appears on index
(e.g. 1234)
Key ENTER
6.4. Press on the program key to initializing the AMR unit.
7. Cover the outdoor screws using seals.
FCC Warning
Modifications not expressly approved by the manufacturer could
void the user authority to operate the equipment under FCC Rules.
Exhibit 1
Exhibit 2

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Producer                        : Acrobat Distiller 4.05 for Windows
Creator                         : Microsoft Word 8.0
Modify Date                     : 2001:01:18 08:37:15+02:00
Author                          : Eli E
Title                           : Nexus data- installation and program initialization manual
Create Date                     : 2001:01:18 08:34:06
Page Count                      : 4
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NL3GA0001

Navigation menu