ECLIPSE 90i/80i Accessories
Advanced Research Microscope Accessories
Accessories
ECLIPSE 90i
ECLIPSE 80i
ECLIPSE i-Series Website
www.nikon-i.com
Epi-fluorescence Accessories
The digital-imaging head and the universal epi-fluorescence illuminator incorporate
Nikon’s unique Noise Terminator to achieve fluorescence images with an
unprecedentedly high signal-to-noise (S/N) ratio. The digital-imaging head comes in two
types: the DIH-E features a motorized switching for the field diaphragm, optical path,
epi-fl filter cube, excitation light shutter, analyzer and optical zoom, while the DIH-M has
a motorized control specifically for the excitation light shutter.
•S/N ratio has been dramatically improved by directing stray light out of the optical path.
•Excitation wavelength can be continuously fine-tuned by adjusting the sliding distance of the
optional Excitation Balancer.
•Six filter cubes can be accommodated, and they are easily exchanged.
•Filters or mirror in the filter cubes can be easily replaced to create the desired combination.
•Filter position labels glow in the dark for easy identification.
•Universally functional for darkfieled, brightfield, Nomarski DIC and other applications using
episcopic illumination in addition to epi-fluorescence microscopy.
1D-DH-E Digital-Imaging Head E Main Body
2Filter Cube Nameplates
3Light Shielding Plate
4Hg Lamphouse HMX-4B
5Aperture Diaphragm
6D-FB Excitation Balancer (optional)
7ND Filters
8C-FC Epi-fl Collector Lens
9Light Shielding Tube
!C-FC Centering Tool
"C-SHG1 Power Supply for HG 100W
#C-FL Epi-fl Filter Cubes
$CFI Plan Fluor Objectives
Epi-fluorescence
2
$
1
2
3
4
5
6
7
8
9
!
"
#
Specific Accessories for D-H-E Motorized Digital Imaging Head (DIH-E)
1D-DH Digital-Imaging Head M Main Body
2D-CB Connector Box
3C-HS Hand Switch
4Filter Cube Nameplates
5Light Shielding Plate
6Hg Lamphouse HMX-4B
7Aperture Diaphragm
8Field Diaphragm
9D-FB Excitation Balancer (optional)
!ND Filters
"C-FC Epi-fl Collector Lens
#Light Shielding Tube
$C-FC Centering Tool
%C-SHG1 Power Supply for HG 100W
&C-FL Epi-fl Filter Cubes
(CFI Plan Fluor Objectives
Specific Accessories for d-FL Universal
Epi-F luorescence Attachment
1D-FL Universal Epi-fluorescence
Attachment
2Filter Cube Nameplates
3Light Shielding Plate
4C-FC Epi-fl Collector Lens
5C-FC Centering Tool
6Hg Lamphouse HMX-4B
7C-SHG1 Power Supply for HG 100W
8CFI Plan Fluor Objectives
9C-FL Epi-fl Filter Cubes
Epi-fluorescence
3
1
23
4
5
6
7
8
9
!
"
#
$
%
&
(
1
2
3
45
6
7
8
9
Specific Accessories for D-H Manual Digital Imaging Head (DIH-M)
Epi-fluorescence Filters
4
Epi-fluorescence Filters
Models Wavelengths Characteristics Applications
GFP-L EX480/40, DM505, BA510 GFP long-pass type GFP
GFP-B EX480/40, DM505, BA535/50 GFP band-pass type GFP
UV-1A EX 365/10 •Narrow band pass – only 365nm (i line) of Mercury spectrum used •DAPI
DM 400 •Narrow band pass minimizes auto-fluorescence and photo-bleaching •Hoechst 33258/33342
BA 400 •AMCA
UV-2A EX 330-380 •Standard filter block for UV •Cascade Blue®
DM 400 •Autofluorescence
BA 420
UV-2B EX 330-380 •Darker background than UV-2A
DM 400
BA 435
UV-2E/C EX 340-380 •For DAPI, cutting off FITC (green) and TRITC (red)
(DAPI) DM 400 •Soft-coated type for high signal/noise
BA 435-485 •Band-Pass Barrier Filter used to cut off green and red
V-2A EX 380-420 •Standard filter block for V •Catecholamine
DM 430 •Serotonin
BA 450 •Tetracycline
BV-1A EX 435/10 •Narrow band pass – only 435nm (g line) of Mercury spectrum used •Quinacrine
EM 455 •Narrow band pass minimizes auto-fluorescence and photo-bleaching •Quinacrine Mustard (QM)
BA 470 •Thioflavine S
BV-2A EX 400-440 •Standard filter block for BV •Acriflavine
DM 455
BA 470
B-1A EX 470-490 •Narrower excitation range than B-2A •FITC
DM 505 •FITC+Counter-stain (TRITC, PI) •Acridine Orange
BA 520 •Auramine O
B-1E EX 470-490 •For FITC (green), cutting off Rhodamine red •Coriphosphine O
DM 505 •Band-Pass Barrier Filter used to cut off red •Bodipy®
BA 520-560 •Fluo-3
B-2A EX 450-490 •Standard filter block for B •DIO
DM 505 •For FITC + Counter-stain (TRITC, PI)
BA 520
B-2E/C EX 465-495 •Soft coated type for high signal/noise
(FITC) DM 505 •For FITC (green), cutting off Rhodamine red
BA 515-555 •Band-pass Barrier Filter used to cut off red
B-3A EX 420-490 •Wide band passs – recommended for halogen illumination only
DM 505
BA 520
G-1B EX 546/10 •Narrow band pass – only 546nm (e line) of Mercury spectrum used •TRITC
DM 575 •Narrow band pass minimizes auto-fluorescence and photo-bleaching •Rhodamine B200
BA 590 •Propidium iodide
G-2A EX 510-560 •Standard filter block for G •R-Phycoerythrin
DM 575 •B-Phycoerythrin
BA 590 •Dil
G-2B EX 510-560 •610nm barrier provides darker background and deep red emission •Ethidium Bromide
DM 575
BA 610
G-2E/C EX 540/25 •For TRITC (Rhodamine)
(TRITC) DM 565 •Soft coated type for high signal/noise
BA 605/55 •Band-Pass Barrier Filter used to cut off reds above 643nm
Y-2E/C EX 540-580 •For Texas Red®•Texas Red®
(Texas Red) DM 595 •Soft coated type for high signal/noise
BA 600-660 •Band-Pass Barrier Filter used to cut off reds above 660nm
Filters Wavelengths Characteristics Applications
U
V
V
B
V
B
G
Y
F-R FITC
Rhodamine
Dual F-T FITC
Texas Red
D-F DAPI
FITC
Filters Abbreviations Applications
Multi-Band Filters
Filter Characteristics
D-F-R DAPI
FITC
Triple Rhodamine
D-F-T DAPI
FITC
Texas Red
Filters Abbreviations Applications
Filters for Fluorescent Protein
Filters Wavelengths
CFP HQ EX420-445, DM450, BA460-510
GFP HQ EX455-485, DM495, BA500-545
YFP HQ EX490-500, DM510, BA520-560
High Quality Filters
Each filter/mirror has a very sharp rising edge at the
corresponding wavelength, minimizing signal crossover.
Nomarski DIC
5
Nomarski DIC Accessories
The new DIC system produces well-balanced images with outstanding
contrast and resolution to produce crisp and clear images with perfectly even
brightness, even during low-magnification observations.
Two types of DIC modules (dry) are enough to cover observations from 10X to 100X.
DIC sliders can be chosen from Standard, High-contrast, and High-resolution types,
depending on the specimen.
Shear direction of DIC images can be adjusted* on a rotatable stage.
*Rotatable stage cannot be mounted on the 80i mechanical-stage model.
Specific Accessories for 90i System
1D-CUD-E Motorized Universal Condenser Dry
2D-C DIC Module Dry
3D-ND6-E Motorized Sextuple DIC Nosepiece
4D-DP DIC Rotatable Polarizer
5D-DA DIC Analyzer
6D-LP Lambda Plate
7D-C DIC Sliders
8CFI Plan Fluor/CFI Plan Apo Objectives
9C-CT Centering Telescope
Specific Accessories for 80i System
1D-CUD Universal Condenser Dry
2D-C DIC Module Dry
3D-ND6 Sextuple DIC Nosepiece
4D-NID6 Intelligent Sextuple DIC Nosepiece
5D-DP DIC Rotatable Polarizer
6D-DA DIC Analyzer
7D-LP Lambda Plate
8D-C DIC Sliders
9CFI Plan Fluor/CFI Plan Apo Objectives
!C-CT Centering Telescope
1
2
3
4
5
67
8
9!
1
2
3
4
56
7
8
9
Epi-fluorescence / DIC
6
This method allows a DIC image to be overlaid with an epi-
fluorescence image within a single view field. This makes the position
identification of a fluorescence specimen easier and more accurate.
In configuration with the DIH-E motorized digital-imaging head and 90i,
the system can automatically optimize settings for epi-fl/DIC
observations at the click of a mouse via the connected PC.
Epi-fluorescence/Nomarski DIC Accessories
Specific Motorized Accessories
1
D-DH-E
Digital-imaging Head E Main Body
2Filter Cube Nameplates
3Light Shielding Plate
4ND Filters
5D-FB Excitation Balancer (optional)
6Aperture Diaphragm
7
D-CUD-E Motorized Universal Condenser Dry
8D-C DIC Module (Dry)
9Light Shielding Tube
!D-DP DIC Rotatable Polalyzer
"D-DA DIC Analyzer
#C-FC Centering Tool
$D-C DIC Slider
%Hg Lamphouse HMX-4B
&C-FC Epi-fl Collector Lens
(
D-ND6-E Motorized Sextuple DIC Nosepiece
)C-SHG1 Power Supply for HG 100W
~C-FL Epi-fl Filter Cubes
+
CFI Plan Fluor/CFI Plan Apo Objectives
Specific Manual Accessories
1
D-DH Digital-imaging Head M Main Body
2Filter Cube Nameplates
3Light Shielding Plate
4D-CB Connector Box
5C-HS Hand Switch
6Aperture Diaphragm
7Field Diaphragm
8D-FB Excitation Balancer (optional)
9ND Filters
!D-CUD Universal Condenser Dry
"D-C DIC Module (Dry)
#Light Shielding Tube
$D-DP DIC Rotatable Polalyzer
%D-DA DIC Analyzer
&C-FC Centering Tool
(D-C DIC Slider
)Hg Lamphouse HMX-4B
~C-FC Epi-fl Collector Lens
+D-ND6 Sextuple DIC Nosepiece
,
D-NID6 Intelligent Sextuple DIC Nosepiece
-
CFI Plan Fluor/CFI Plan Apo Objectives
.C-SHG1 Power Supply for HG100W
/C-FL Epi-fl Filter Cubes
1
2
3
4
5
6
7
8
9
!
"
#
$
%
&
(
)
~
+
,
-
.
/
1
2
3
4
5
6
7
8
9
!
"
#
$
%
&
(
)
~+
Phase Contrast
7
Darkfield
Simple Polarizing
Sensitive Color Polarizing
These accessories produce well-defined high contrast images with
neutral background coloration regardless of the magnification range.
The CFI Plan Fluor DLL objectives can be universally used for phase
contrast, epi-fluorescence, brightfield, as well as DIC applications.
The CFI Achromat ADL objectives clearly visualize the minute
structure of thick phase objects by minimizing halos.
*For phase contrast applications on the 80i rotatable mechanical stage model,
a universal condenser must be used.
Phase Contrast Accessories (80i)
These dedicated darkfield accessories allow clear observation of
blood or the minute structure of flagella. Dry- and oil-type
condensers are available. The expander lens is used to obtain
illumination with greater brightness. It is also possible to perform
darkfield microscopy using a universal condenser or phase contrast
condenser.
Darkfield Accessories
Ideal for observing birefringent samples such as collagen, amyloids
and crystals. Operation is as simple as inserting a polarizer over the
field lens and an analyzer in the arm slot. The field number has been
increased to 25.
Simple Polarizing Accessories
Enables gout and pseudo-gout tests easily.
Sensitive Color Polarizing Accessories
Specific Accessories for Rotatable
Mechanical Stage Model
1D-CUD Universal Condenser (Dry)
2D-C PH Module
3CFI Plan Fluor DLL Objectives
4C-CT Centering Telescope
Specific Accessories for Mechanical
Stage Model
1C-C Phase Contrast Condenser
2CFI Plan Fluor DLL Objectives
3Filter, 45mm GIF
4C-CT Centering Telescope
Specific Accessories
1C-CEL Expander Lens
2C-C Darkfield Condenser (Dry)
3C-C Darkfield Condenser (Oil)
Specific Accessories
1C-SP Simple Polarizer
2C-ISA Intermediate Tube w/Simple Analyzer
Specific Accessories
1C-TP Polarizer with First-order Red Tint Plate
2C-IA Intermediate Tube with Analyzer
1
2
3
1
2
3
4
4
123
1
2
1
2
Accessories
8
Name (Magnification) Field Number Reticule
CFI 10X 22
CFI 10XM 22 Photomask
CFI 12.5X 16
CFI 15X 14.5
CFI UW 10X 25
CFI UW 10XM 25 Photomask
2.5X, 4X relay lenses are ideal for video enhanced contrast (VEC
applications. Use 0.35X, 0.45X and 0.7X relay lenses for 1/3-, 1/2-, 2/3-inch
CCD cameras, respectively. 0.9 to 2.2X zoom relay lenses are also available.
Other Accessories
Eyepiece Tubes
Eyepiece Lenses
Condensers
CCTV Adapters
The DIC-type nosepiece allows researchers to individually mount DIC
sliders for each objective. The intelligent-type nosepiece allows objective
information to be recorded with the image when it is captured with a Digital
Sight–series digital camera. Two motorized types are available for the 90i,
according to use.
Nosepieces
The image can be rotated and the polarizing direction adjusted on the
rotatable stage. The specimen can be moved in the XY direction on the
motorized stage.
Stages
2-slide holders and a single-slide
holder enabling the quick exchange
of the specimen with one hand are
available.
Specimen Holders
Name Beam Split Ratio Field Number ISO Photo Tube
Binocular Tube B Observation 100% 22
Trinocular Tube FUW Observation 100% / Photo 100% 22/25 Attachable
Trinocular Tube TUW Observation 100% / Photo 100% /
Observation 20%, Photo 80% 22/25 Attachable
Ergonomic Binocular Tube Observation 100% / 22
Observation 50%, Photo 50%
(with DSC port)
Type N.A. W.D.
Objective Mag.
(mm) (F.O.V. 22)
Abbe Condenser 0.9 1.9 4
-
100X
Achromat Condenser 0.85 4.2 4
-
100X
Achromat Swing-out Condenser 1-100X
0.8/0.12 3.2 1
-
100X
Achromat Aplanat Condenser
1.40 1.6 10
-
100X
LWD Achromat Condenser 0.65 10.2 4
-
40X
Low Power Condenser 0.15 10.2 1
-
4X
Darkfield Condenser (Dry) 0.8
-
0.95 4 10
-
40X
Darkfield Condenser (Oil) 1.2
-
1.43 1.5 20
-
100X
Phase Contrast Condenser*10.9 1.9 10
-
100X
Universal Condenser (Dry) 0.9/0.13 2.3 2
-
100X
DIC Condenser (Oil) 1.4 1.6 10
-
100X
Motorized Universal Condenser (Dry)*
20.9/0.13 2.3 2-100X
*1 Cannot be mounted on the 90i and 80i rotatable mechanical stage models.
*
2 90i only.
C-N6 Sextuple Nosepiece
C-ND6 Sextuple DIC Nosepiece
D-NID6 Intelligent Sextuple DIC Nosepiece
D-NI7 Intelligent Septuple Nosepiece
D-ND6-E Motorized Sextuple DIC Nosepiece (90i)
D-N7-E Motorized Septuple Nosepiece (90i)
DSC Port (for Ergo Tube) With C-mount 0.7X lens
C-SR Mechanical Stage (for 80i mechanical stage)
C-SRR Rotatable Mechanical Stage (for 90i/80i rotatable mechanical stage)
D-S-E Motorized XY stage (90i only)
Specimen holders available separately.
Accessories
9
The drawing tube allows both the image of a
specimen and the drawing to be seen through
the eyepieces. A dedicated adapter is necessary
to attach it.
The double port enables the use of one CCTV camera
and one digital camera, or two digital cameras
simultaneously.
The turret system allows the intermediate
magnification to be changed to 1X, 1.25X,
1.5X or 2X.
The FX-III series utilizes a direct-projection system with a swing-out prism
for fast exposure setting and accurate metering.
U-III : 0.1% and 1% spot exposure, and 35% integrated-average
measurement modes
H-III : 1% spot and 35% integrated-average measurement modes
P-III : Manual exposure model
The double-lamphouse adapter allows
two different light sources to be
simultaneously attached to the
microscope, eliminating the need to
change the lamphouse and carry out
time-consuming centering procedures.
Two CCTV cameras or one CCTV camera and a
digital camera can be attached to the trinocular
eyepiece tube while maintaining the same eye level.
5-person type
Various types from 2-person (side by side or face-to-face) to 10-person
types are available.
Teaching Heads
The Ergo Controller allows focus
adjustments, stage movements and
objective lens changeovers to be performed
in front of a PC monitor as if operating the
actual microscope.
Ergo Controller (90i only)
The Motorized ND Filter Unit
automatically selects the optimum
filter type after a change of the
objective.
Motorized ND Filter Unit (90i only)
Drawing Tube
Double port
Magnification module
FX-III series photomicrographic equipment
Quadrocular Adapter
Double-lamphouse Adapter
H-III
CFI Objectives
10
Brightfield
(CFI)
Type Achromat Plan Achromat Fluor Super Fluor
Use
Phase
Contrast
(CFI)
New Phase
Contrast
(CFI)
Polarizing
(CFI)
Brightfield
(CFI Plan)
No Cover
(CFI Plan)
Phase
Contrast
(CFI Plan)
Epi-fl
(CFI Fluor)
Epi-fl
(CFI S Fluor)
Type Plan Fluor Plan Apochromat
Use
Epi-fl
(CFI Plan Fluor)
Phase
Contrast
(CFI Plan Fluor)
Brightfield
(CFI Plan Apo)
Evanescent
TIRF
(CFI Plan Apo)
CFI Objectives
Phase
Contrast
(CFI Plan Apo)
Name N.A. W.D. Cover-glass
(mm) Thickness
4X 0.10 30.00 -
10X 0.25 7.00 -
LWD 20X 0.40 3.90 0.17
40X 0.65 0.65 0.17
LWD 40XC 0.55 2.7-1.7 0-2.0
60X 0.80 0.30 0.17
100XH 1.25 0.23 0.17
100XH( iris)
0.5-1.25
0.23 0.17
DL 10X 0.25 7.00 -
LWD DL 20X 0.40 3.90 0.17
LWD DL 20XF 0.40 3.10 1.2
DL 40X 0.65 0.65 0.17
LWD DL 40XC 0.55 2.7-1.7 0-2.0
DL 100XH 1.25 0.23 0.17
BM 10XA 0.25 6.10 -
ADL 10X 0.25 6.20 1.2
LWD ADL 20XF 0.40 3.10 1.2
LWD ADL 40XF 0.55 2.10 1.2
LWD ADL 40XC 0.55 2.7-1.7 0-2.0
P 4X 0.10 30.00 -
P 10X 0.25 7.00 -
LWD P 20X 0.40 3.90 0.17
P 40X 0.65 0.65 0.17
P 100XH 1.25 0.23 0.17
UW 1X 0.04 3.20 -
UW 2X 0.06 7.50 -
4X 0.10 30.00 -
10X 0.25 10.50 -
20X 0.40 1.20 0.17
40X 0.65 0.56 0.17
50XH 0.90 0.35 -
100XH 1.25 0.20 0.17
NCG 40X 0.65 0.48 0
NCG 100X 0.90 0.26 0
DL 10X 0.25 10.50 -
DL 20X 0.40 1.20 0.17
DL 40X 0.65 0.56 0.17
DL 100XH 1.25 0.20 0.17
10XW 0.30 2.00 0
20XW 0.50 2.00 0
40XW 0.80 2.00 0
60XW 1.00 2.00 0
4X 0.20 15.5 -
10X 0.50 1.20 0.17
20X 0.75 1.00 0.17
40X 0.90 0.30 0.11-0.23
40XH 1.30 0.22 0.17
100XH( iris) 0.5-1.3 0.20 0.17
Name N.A. W.D. Cover-glass
(mm) Thickness
4X 0.13 17.10 -
10X 0.30 16.00 0.17
20X 0.50 2.10 0.17
20XMi 0.75 0.35 0.17
(
Multi-immersion
)
40X 0.75 0.72 0.17
40XH 1.30 0.20 0.17
60X 0.85 0.30 0.11-0.23
60XSH ( iris)
0.5-1.25
0.22 0.17
100X 0.90 0.30 0.14-0.20
100XH 1.30 0.2 0.17
100XH ( iris ) 0.5-1.3 0.2 0.17
DL 4X 0.13 16.40 1.2
DL 10X 0.30 15.20 1.2
DLL 10X 0.30 16.00 -
DLL 20X 0.50 2.10 0.17
DLL 40X 0.75 0.72 0.17
DLL 100XH 1.30 0.20 0.17
2X 0.10 8.50 -
4X 0.20 15.70 -
10X 0.45 4.00 0.17
20X 0.75 1.00 0.17
40X 0.95 0.14 0.11-0.23
40XH 1.00 0.16 0.17
60X 0.95 0.15 0.11-0.23
60XH 1.40 0.21 0.17
VC 60XH 1.40 0.13 0.17
VC 60XWI 1.20 0.27 0.15-0.18
VC 100XH 1.40 0.13 0.17
NCG 100XH 1.40 0.17 0
TIRF 60XH 1.45 0.13 0.10-0.22
TIRF 100XH 1.45 0.13 0.17
DM 20X 0.75 1.00 0.17
DM 40X 0.95 0.14
0.11-0.23
DM 40XH 1.00 0.16 0.17
DM 60X 0.95 0.15
0.11-0.23
DM 60XH 1.40 0.13 0.17
DM 100XH 1.40 0.13 0.17
90i/80i Specifications
11
Eclipse 90i/80i Specifications
90i 80i
Main Body Optical system CFI60 infinity optical system
Base Mechanical stage model / Rotatable stage model
Illumination Precentered 12V100W halogen transmitted illumination Precentered 12V100W halogen transmitted illumination
Built-in fly-eye lens Built-in fly-eye lens
Built-in NCB11/ ND8/ ND32 filters (detachable ) & Built-in NCB11/ ND8/ ND32 filters (detachable ) & diffuser
diffuser (not detachable) (not detachable)
Preset switch Preset switch
Motorized field diaphragm Built-in power supply
External power supply
Motorized ND filter unit for light intensity control
available as option
Focusing Motorized coaxial coarse/fine/super-fine focusing Manual coaxial coarse/fine focusing
Built-in linear encoder, resolution : 0.05um Focusing stroke : 27mm
Focusing stroke : 27mm Coarse : 14mm/rotation, Fine : 0.1mm/rotation
Escape function as refocusing mechanism Minimum reading : 1um
Auto Link Focus Refocusing mechanism with focus clamp
Coarse motion torque adjustable
Eyepiece Tube Y-TB Binocular Tube F.O.V. 22
(Light distribution) Y-TF Trinocular Tube F UW F.O.V. 22/25mm (Eyepiece/Port : 100/0, 0/100)
Y-TT Trinocular Tube T UW F.O.V. 22/25mm (Eyepiece/Port : 100/0, 20/80, 0/100)
C-TE Ergonomic Binocular Tube F.O.V. 22mm inclination angle : 10-30 tube extension up to 40mm
(when C-TEP DSC port is attached: Eyepiece/Port 100/0, 50/50
D-DH Digital Imaging Head / D-DH-E Motorized Digital Imaging Head F.O.V. 22/25mm
(Eyepiece/Front Port/Rear Port : 100/0/0/, 0/100/0, 0/0/100*) *A 30/0/70 type is also available for DIH-M.
Eyepiece Lens 10X (22mm), 10X M photomask (25mm), 12.5X (16mm), 15X (14.5),
(F.O.V.) UW10X (25mm), UW 10X M photomask (25mm)
Nosepiece D-N7-E Motorized Septuple Nosepiece D-NI7 Intelligent Septuple Nosepiece
D-ND6-E Motorized Sextuple DIC Nosepiece D-NID6 Intelligent Sextuple DIC Nosepiece
D-NI7 Intelligent Septuple Nosepiece C-N Sextuple Nosepiece
D-NID6 Intelligent Sextuple DIC Nosepiece D-ND6 Sextuple DIC Nosepiece
C-N Sextuple Nosepiece, D-ND6 Sextuple DIC Nosepiece
Stage C-SRR Rotatable Rectangular Mechanical Stage C-SRR Rotatable Rectangular Mechanical Stage
(Ball bearing mechanism) (Centerable, rotation angle 220˚)
Cross travel 78(X) x 54(Y) mm, with calibrations, C-SR Rectangular Mechanical Stage
stage handle height and torque adjustable, rackless Cross travel 78(X) x 54(Y) mm, with calibrations,
D-S-E Motorized XY Stage Stay-in -position stage handle height and torque adjustable, rackless
Cross travel 78(X) x 54(Y) mm, Repeatability : ±10µm C-HC1/HL2 Specimen Holders for 1 slide/2 slides
C-HC1/HL2 Specimen Holders for 1 slide/2 slides
Condenser D-CUD-E Motorized Universal Condenser Dry D-CUD Universal Dry, D-CUO DIC Oil,
(Motorized 7-position turret and aperture diaphragm), C-C Abbe, C-C Achromat, C-C Achromat Swing-out 1-100X,
D-CUD Universal Dry, D-CUO DIC Oil, C-C Low Power, C-C Achromat/Aplanat,
C-C Abbe, C-C Achromat, C-C Achromat Swing-out 1-100X, C-C Phase Contrast, Darkfield (Dry/Oil), LWD Achromat
C-C Low Power, C-C Achromat/Aplanat,
Darkfield (Dry/Oil), LWD Achromat
Power Consumption (max.) 100-230V, 2.8A/210W 100-230V, 2.4A/170W
Weight (approx.) 18.2 kg (standard trinocular set)
DIH-E DIH-M Universal Epi-fluorescence Illuminator
Applications Epi-fluorescence, Epi-brightfield, Epi-darkfield, Epi-DIC, Epi-simple polarizing, Confocal
Light distribution Observation/front port/rear port: 100/0/0, 0/100/0, 0/0/100 100/0/0, 0/100/0, 0/0/100 * Depends on eyepiece tube used
* A 30/0/70 type is also available.
Motorized switching Manual switching
Optical output ports Font port: 1X, diameter ø52mm
Rear port: optical zoom 0.8-2.0X (continuous), zoom ratio 2.5 : 1, C-mount Not available
Motorized Manual
Inclination angle 25° Depends on eyepiece tube used
F.O.V. 22, 25mm
Filter turret 6 filter cubes mountable
Motorized Manual
Hi S/N Noise Terminator mechanism Available
Excitation light balancer Available
Aperture diaphragm Centerable, detachable, diameter ø1-9mm (manual)
Field diaphragm Centerable, not detachable, diameter ø1-9mm
Motorized Manual
ND filters ND4, ND8, ND16 (manual)
Excitation light shutter Motorized Manual
Analyzer Motorized Manual (with slot)
Polarizer Manual (with slot)
Light source Mercury, xenon, halogen (centerable)
External connection USB, C1 interlock, external connection connector Not available
Status-check function Available (data can be recorded with image captured by Digital Sight digital camera) Not available
Compatible microscopes 90i, 80i 90i, 80i, E600, E600FN, ME600L, L150
En
This brochure is printed on recycled paper made from 40% used material.
Printed in Japan (0501-10)T Code No. 2CE-MSLH-2
Digital-imaging Heads, Universal Epi-fluorescence Illuminator Specifications
Specifications and equipment are subject to change without any notice
or obligation on the part of the manufacturer. January 2005.
©2004 NIKON CORPORATION
WARNING TO ENSURE CORRECT USAGE, READ THE CORRESPONDING
MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.
Company names and product names appearing in this brochure are their registered
trademarks or trademarks.
www.nikon.com/
Fuji Bldg., 2-3, Marunouchi 3-chome, Chiyoda-ku,
Tokyo 100-8331, Japan
NIKON CORPORATION
NIKON INSTECH CO., LTD.
Parale Mitsui Bldg., 8, Higashida-cho, Kawasaki-ku,
Kawasaki, Kanagawa 210-0005, Japan
phone: +81-44-223-2167 fax: +81-44-223-2182
www.nikon-instruments.jp/eng/
NIKON INSTRUMENTS (SHANGHAI) CO., LTD.
CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030
(Beijing office)
CHINA phone: +86-10-5869-2255 fax: +86-10-5869-2277
NIKON SINGAPORE PTE LTD
SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668
NIKON MALAYSIA SDN. BHD.
MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387
NIKON INSTRUMENTS EUROPE B.V.
P.O. Box 222, 1170 AE Badhoevedorp, The Netherlands
phone: +31-20-44-96-222 fax: +31-20-44-96-298
www.nikon-instruments.com/
NIKON FRANCE S.A.S.
FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33
NIKON GMBH
GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322
NIKON INSTRUMENTS S.p.A.
ITALY phone: + 39-55-3009601 fax: + 39-55-300993
NIKON AG
SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861
NIKON UK LTD.
UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-4584
NIKON INSTRUMENTS INC.
1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.
phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A.only) fax: +1-631-547-0306
www.nikonusa.com/
NIKON CANADA INC.
CANADA phone: +1-905-625-9910 fax: +1-905-625-0103
Page 1 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 2 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 3 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 4 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 5 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 6 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 7 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 8 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 9 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 10 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 11 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2
Page 12 of 12 - Nikon 90i/80iiE_Accessories If Not Then  90i80i-acc 2ce-msoh-2

Navigation menu