ECLIPSE 90i/80i Accessories

Accessories
Advanced Research Microscope Accessories

ECLIPSE 80i
ECLIPSE 90i

ECLIPSE i-Series Website

www.nikon-i.com

Epi-fluorescence

Epi-fluorescence Accessories
The digital-imaging head and the universal epi-fluorescence illuminator incorporate
Nikon’s unique Noise Terminator to achieve fluorescence images with an
unprecedentedly high signal-to-noise (S/N) ratio. The digital-imaging head comes in two
types: the DIH-E features a motorized switching for the field diaphragm, optical path,
epi-fl filter cube, excitation light shutter, analyzer and optical zoom, while the DIH-M has
a motorized control specifically for the excitation light shutter.
•S/N ratio has been dramatically improved by directing stray light out of the optical path.
•Excitation wavelength can be continuously fine-tuned by adjusting the sliding distance of the
optional Excitation Balancer.
•Six filter cubes can be accommodated, and they are easily exchanged.
•Filters or mirror in the filter cubes can be easily replaced to create the desired combination.
•Filter position labels glow in the dark for easy identification.
•Universally functional for darkfieled, brightfield, Nomarski DIC and other applications using
episcopic illumination in addition to epi-fluorescence microscopy.

"
4

1

5

8

6
9

7
!
2

#

3
$

■ Specific Accessories for D-H-E Motorized Digital Imaging Head (DIH-E)
1 D-DH-E Digital-Imaging Head E Main Body

8 C-FC Epi-fl Collector Lens

2 Filter Cube Nameplates

9 Light Shielding Tube

3 Light Shielding Plate

! C-FC Centering Tool

4 Hg Lamphouse HMX-4B

" C-SHG1 Power Supply for HG 100W

5 Aperture Diaphragm

# C-FL Epi-fl Filter Cubes

6 D-FB Excitation Balancer (optional)

$ CFI Plan Fluor Objectives

7 ND Filters

2

Epi-fluorescence

%

6

3

2

1
7

"

8
9

#

!

$

4

&

5
(

■ Specific Accessories for D-H Manual Digital Imaging Head (DIH-M)
1 D-DH Digital-Imaging Head M Main Body

9 D-FB Excitation Balancer (optional)

2 D-CB Connector Box

! ND Filters

3 C-HS Hand Switch

" C-FC Epi-fl Collector Lens

4 Filter Cube Nameplates

# Light Shielding Tube

5 Light Shielding Plate

$ C-FC Centering Tool

6 Hg Lamphouse HMX-4B

% C-SHG1 Power Supply for HG 100W

7 Aperture Diaphragm

& C-FL Epi-fl Filter Cubes

8 Field Diaphragm

( CFI Plan Fluor Objectives

7

■ Specific Accessories for d-FL Universal
Epi-F luorescence Attachment

6

1 D-FL Universal Epi-fluorescence
Attachment
2 Filter Cube Nameplates
3 Light Shielding Plate
8

1

4 C-FC Epi-fl Collector Lens
5 C-FC Centering Tool
6 Hg Lamphouse HMX-4B

2

7 C-SHG1 Power Supply for HG 100W
9
3

5

8 CFI Plan Fluor Objectives
9 C-FL Epi-fl Filter Cubes

4

3

Epi-fluorescence Filters

Epi-fluorescence Filters
Filter Characteristics
Filters
UV-1A
UV-2A

U
V

UV-2B
UV-2E/C
(DAPI)

V

V-2A
BV-1A

B
V

BV-2A
B-1A
B-1E

B

B-2A
B-2E/C
(FITC)
B-3A
G-1B
G-2A

G

G-2B
G-2E/C
(TRITC)

Y

Y-2E/C
(Texas Red)

Wavelengths
EX 365/10
DM 400
BA 400
EX 330-380
DM 400
BA 420
EX 330-380
DM 400
BA 435
EX 340-380
DM 400
BA 435-485
EX 380-420
DM 430
BA 450
EX 435/10
EM 455
BA 470
EX 400-440
DM 455
BA 470
EX 470-490
DM 505
BA 520
EX 470-490
DM 505
BA 520-560
EX 450-490
DM 505
BA 520
EX 465-495
DM 505
BA 515-555
EX 420-490
DM 505
BA 520
EX 546/10
DM 575
BA 590
EX 510-560
DM 575
BA 590
EX 510-560
DM 575
BA 610
EX 540/25
DM 565
BA 605/55
EX 540-580
DM 595
BA 600-660

Characteristics
•Narrow band pass – only 365nm (i line) of Mercury spectrum used
•Narrow band pass minimizes auto-fluorescence and photo-bleaching
•Standard filter block for UV

Applications
•DAPI
•Hoechst 33258/33342
•AMCA
•Cascade Blue®
•Autofluorescence

•Darker background than UV-2A
•For DAPI, cutting off FITC (green) and TRITC (red)
•Soft-coated type for high signal/noise
•Band-Pass Barrier Filter used to cut off green and red
•Standard filter block for V
•Narrow band pass – only 435nm (g line) of Mercury spectrum used
•Narrow band pass minimizes auto-fluorescence and photo-bleaching
•Standard filter block for BV
•Narrower excitation range than B-2A
•FITC+Counter-stain (TRITC, PI)

•Catecholamine
•Serotonin
•Tetracycline
•Quinacrine
•Quinacrine Mustard (QM)
•Thioflavine S
•Acriflavine

•FITC
•Acridine Orange
•Auramine O
•Coriphosphine O
•Bodipy®
•Fluo-3
•DIO

•For FITC (green), cutting off Rhodamine red
•Band-Pass Barrier Filter used to cut off red
•Standard filter block for B
•For FITC + Counter-stain (TRITC, PI)
•Soft coated type for high signal/noise
•For FITC (green), cutting off Rhodamine red
•Band-pass Barrier Filter used to cut off red
•Wide band passs – recommended for halogen illumination only
•Narrow band pass – only 546nm (e line) of Mercury spectrum used
•Narrow band pass minimizes auto-fluorescence and photo-bleaching
•Standard filter block for G
•610nm barrier provides darker background and deep red emission
•For TRITC (Rhodamine)
•Soft coated type for high signal/noise
•Band-Pass Barrier Filter used to cut off reds above 643nm
•For Texas Red®
•Soft coated type for high signal/noise
•Band-Pass Barrier Filter used to cut off reds above 660nm

•TRITC
•Rhodamine B200
•Propidium iodide
•R-Phycoerythrin
•B-Phycoerythrin
•Dil
•Ethidium Bromide

•Texas Red®

Multi-Band Filters
Filters

Dual

Abbreviations
F-R
F-T
D-F

Applications
FITC
Rhodamine
FITC
Texas Red
DAPI
FITC

Filters

Triple

Filters for Fluorescent Protein
Models
GFP-L
GFP-B

4

Wavelengths
EX480/40, DM505, BA510
EX480/40, DM505, BA535/50

Abbreviations

Applications

D-F-R

DAPI
FITC
Rhodamine
DAPI
FITC
Texas Red

D-F-T

High Quality Filters
Characteristics
GFP long-pass type
GFP band-pass type

Applications
GFP
GFP

Each filter/mirror has a very sharp rising edge at the
corresponding wavelength, minimizing signal crossover.
Filters
CFP HQ
GFP HQ
YFP HQ

Wavelengths
EX420-445, DM450, BA460-510
EX455-485, DM495, BA500-545
EX490-500, DM510, BA520-560

Nomarski DIC

Nomarski DIC Accessories
The new DIC system produces well-balanced images with outstanding
contrast and resolution to produce crisp and clear images with perfectly even
brightness, even during low-magnification observations.
• Two types of DIC modules (dry) are enough to cover observations from 10X to 100X.
• DIC sliders can be chosen from Standard, High-contrast, and High-resolution types,
depending on the specimen.
• Shear direction of DIC images can be adjusted* on a rotatable stage.
*Rotatable stage cannot be mounted on the 80i mechanical-stage model.

■ Specific Accessories for 90i System
1

1 D-CUD-E Motorized Universal Condenser Dry

3

2 D-C DIC Module Dry
3 D-ND6-E Motorized Sextuple DIC Nosepiece
5

4 D-DP DIC Rotatable Polarizer

6

5 D-DA DIC Analyzer

4

6 D-LP Lambda Plate
7
2

7 D-C DIC Sliders
8 CFI Plan Fluor/CFI Plan Apo Objectives
9 C-CT Centering Telescope

8
9

■ Specific Accessories for 80i System

3
4
1

1 D-CUD Universal Condenser Dry
2 D-C DIC Module Dry
3 D-ND6 Sextuple DIC Nosepiece
4 D-NID6 Intelligent Sextuple DIC Nosepiece

6
2

5 D-DP DIC Rotatable Polarizer

7

5

6 D-DA DIC Analyzer
8

7 D-LP Lambda Plate
8 D-C DIC Sliders
9 CFI Plan Fluor/CFI Plan Apo Objectives
! C-CT Centering Telescope

9

!

5

Epi-fluorescence / DIC

Epi-fluorescence/Nomarski DIC Accessories
This method allows a DIC image to be overlaid with an epifluorescence image within a single view field. This makes the position
identification of a fluorescence specimen easier and more accurate.
In configuration with the DIH-E motorized digital-imaging head and 90i,
the system can automatically optimize settings for epi-fl/DIC
observations at the click of a mouse via the connected PC.

■ Specific Motorized Accessories
1 D-DH-E Digital-imaging Head E Main Body
2 Filter Cube Nameplates
3 Light Shielding Plate
4 ND Filters
5 D-FB Excitation Balancer (optional)
6 Aperture Diaphragm

)

%
7

7 D-CUD-E Motorized Universal Condenser Dry
8 D-C DIC Module (Dry)

1

9 Light Shielding Tube
! D-DP DIC Rotatable Polalyzer

8

6

" D-DA DIC Analyzer

5
&

9

4
!

2

# C-FC Centering Tool

#

$ D-C DIC Slider

(

$

% Hg Lamphouse HMX-4B

"

3

& C-FC Epi-fl Collector Lens
( D-ND6-E Motorized Sextuple DIC Nosepiece

+

~

) C-SHG1 Power Supply for HG 100W
~ C-FL Epi-fl Filter Cubes
+ CFI Plan Fluor/CFI Plan Apo Objectives

)
!

4
1

5
6
7

"

8
2

&

.

~

#

9

+

$

3

%

,
(
" D-C DIC Module (Dry)
-

/

6

# Light Shielding Tube

■ Specific Manual Accessories

$ D-DP DIC Rotatable Polalyzer

1 D-DH Digital-imaging Head M Main Body

% D-DA DIC Analyzer

2 Filter Cube Nameplates

& C-FC Centering Tool

3 Light Shielding Plate

( D-C DIC Slider

4 D-CB Connector Box

) Hg Lamphouse HMX-4B

5 C-HS Hand Switch

~ C-FC Epi-fl Collector Lens

6 Aperture Diaphragm

+ D-ND6 Sextuple DIC Nosepiece

7 Field Diaphragm

, D-NID6 Intelligent Sextuple DIC Nosepiece

8 D-FB Excitation Balancer (optional)

- CFI Plan Fluor/CFI Plan Apo Objectives

9 ND Filters

. C-SHG1 Power Supply for HG100W

! D-CUD Universal Condenser Dry

/ C-FL Epi-fl Filter Cubes

These accessories produce well-defined high contrast images with
neutral background coloration regardless of the magnification range.
The CFI Plan Fluor DLL objectives can be universally used for phase
contrast, epi-fluorescence, brightfield, as well as DIC applications.
The CFI Achromat ADL objectives clearly visualize the minute
structure of thick phase objects by minimizing halos.

Phase Contrast

Phase Contrast Accessories (80i)
1
3

4

*For phase contrast applications on the 80i rotatable mechanical stage model,
a universal condenser must be used.

2

1

2

■ Specific Accessories for Rotatable
Mechanical Stage Model

■ Specific Accessories for Mechanical
Stage Model

1 D-CUD Universal Condenser (Dry)

1 C-C Phase Contrast Condenser

2 D-C PH Module

2 CFI Plan Fluor DLL Objectives

3 CFI Plan Fluor DLL Objectives

3 Filter, 45mm GIF

4 C-CT Centering Telescope

4 C-CT Centering Telescope

3
4

Darkfield

Darkfield Accessories
These dedicated darkfield accessories allow clear observation of
blood or the minute structure of flagella. Dry- and oil-type
condensers are available. The expander lens is used to obtain
illumination with greater brightness. It is also possible to perform
darkfield microscopy using a universal condenser or phase contrast
condenser.

1

2

3

■ Specific Accessories
1 C-CEL Expander Lens
2 C-C Darkfield Condenser (Dry)
3 C-C Darkfield Condenser (Oil)

Simple Polarizing

Simple Polarizing Accessories
Ideal for observing birefringent samples such as collagen, amyloids
and crystals. Operation is as simple as inserting a polarizer over the
field lens and an analyzer in the arm slot. The field number has been
increased to 25.

1
2

■ Specific Accessories
1 C-SP Simple Polarizer
2 C-ISA Intermediate Tube w/Simple Analyzer

Sensitive Color Polarizing

Sensitive Color Polarizing Accessories
Enables gout and pseudo-gout tests easily.

1
2

■ Specific Accessories
1 C-TP Polarizer with First-order Red Tint Plate
2 C-IA Intermediate Tube with Analyzer

7

Accessories

Other Accessories
Stages

Eyepiece Tubes

The image can be rotated and the polarizing direction adjusted on the
rotatable stage. The specimen can be moved in the XY direction on the
motorized stage.

Name

Beam Split Ratio

Field Number

Binocular Tube B

Observation 100%

22

Trinocular Tube FUW

Observation 100% / Photo 100%

22/25

Trinocular Tube TUW

Observation 100% / Photo 100% /
Observation 20%, Photo 80%

22/25

Ergonomic Binocular Tube

Observation 100% /
Observation 50%, Photo 50%
(with DSC port)

DSC Port (for Ergo Tube)

ISO Photo Tube

C-SR Mechanical Stage (for 80i mechanical stage)
C-SRR Rotatable Mechanical Stage (for 90i/80i rotatable mechanical stage)

Attachable

D-S-E Motorized XY stage (90i only)
Specimen holders available separately.

Attachable

22

With C-mount 0.7X lens

Specimen Holders
2-slide holders and a single-slide
holder enabling the quick exchange
of the specimen with one hand are
available.

Eyepiece Lenses
Condensers

Name (Magnification)

Field Number

CFI 10X

22

CFI 10XM

22

CFI 12.5X

16

CFI 15X

14.5

CFI UW 10X

25

CFI UW 10XM

25

Reticule
Photomask

Photomask

Nosepieces
The DIC-type nosepiece allows researchers to individually mount DIC
sliders for each objective. The intelligent-type nosepiece allows objective
information to be recorded with the image when it is captured with a Digital
Sight–series digital camera. Two motorized types are available for the 90i,
according to use.

Objective Mag.
(F.O.V. 22)
Abbe Condenser
0.9
4-100X
Achromat Condenser
0.85
4-100X
Achromat Swing-out Condenser 1-100X
0.8/0.12
1-100X
Achromat Aplanat Condenser
1.40
10-100X
LWD Achromat Condenser
0.65
4-40X
Low Power Condenser
0.15
1-4X
Darkfield Condenser (Dry)
0.8-0.95
10-40X
Darkfield Condenser (Oil)
1.2-1.43
20-100X
Phase Contrast Condenser *1
0.9
10-100X
Universal Condenser (Dry)
0.9/0.13
2-100X
DIC Condenser (Oil)
1.4
10-100X
Motorized Universal Condenser (Dry)*2
0.9/0.13
2-100X
*1 Cannot be mounted on the 90i and 80i rotatable mechanical stage models. *2 90i only.
Type

N.A.

W.D.
(mm)
1.9
4.2
3.2
1.6
10.2
10.2
4
1.5
1.9
2.3
1.6
2.3

CCTV Adapters
2.5X, 4X relay lenses are ideal for video enhanced contrast (VEC
applications. Use 0.35X, 0.45X and 0.7X relay lenses for 1/3-, 1/2-, 2/3-inch
CCD cameras, respectively. 0.9 to 2.2X zoom relay lenses are also available.

8

C-N6

Sextuple Nosepiece

C-ND6

Sextuple DIC Nosepiece

D-NID6

Intelligent Sextuple DIC Nosepiece

D-NI7

Intelligent Septuple Nosepiece

D-ND6-E

Motorized Sextuple DIC Nosepiece (90i)

D-N7-E

Motorized Septuple Nosepiece (90i)

Magnification module

The Ergo Controller allows focus
adjustments, stage movements and
objective lens changeovers to be performed
in front of a PC monitor as if operating the
actual microscope.

The turret system allows the intermediate
magnification to be changed to 1X, 1.25X,
1.5X or 2X.

Accessories

Ergo Controller ( 90i only)

FX-III series photomicrographic equipment

Motorized ND Filter Unit ( 90i only )

The FX-III series utilizes a direct-projection system with a swing-out prism
for fast exposure setting and accurate metering.
U-III: 0.1% and 1% spot exposure, and 35% integrated-average
measurement modes
H-III: 1% spot and 35% integrated-average measurement modes
P-III: Manual exposure model

The Motorized ND Filter Unit
automatically selects the optimum
filter type after a change of the
objective.

H-III

Teaching Heads
Various types from 2-person (side by side or face-to-face) to 10-person
types are available.

Quadrocular Adapter
Two CCTV cameras or one CCTV camera and a
digital camera can be attached to the trinocular
eyepiece tube while maintaining the same eye level.

5-person type

Double-lamphouse Adapter
Drawing Tube
The drawing tube allows both the image of a
specimen and the drawing to be seen through
the eyepieces. A dedicated adapter is necessary
to attach it.

The double-lamphouse adapter allows
two different light sources to be
simultaneously attached to the
microscope, eliminating the need to
change the lamphouse and carry out
time-consuming centering procedures.

Double port
The double port enables the use of one CCTV camera
and one digital camera, or two digital cameras
simultaneously.

9

CFI Objectives

CFI Objectives

Brightfield
(CFI)

4X

0.10

30.00

-

4X

0.13

17.10

-

10X

0.25

7.00

-

10X

0.30

16.00

0.17

0.40

3.90

0.17

20X

0.50

2.10

0.17

0.65

0.17

0.75

0.35

0.17

LWD 40XC

0.55

2.7-1.7

0-2.0

20XMi
(Multi-immersion)

60X

0.80

0.30

0.17

40X

0.75

0.72

0.17

1.30

0.20

0.17

0.85

0.30

0.11-0.23

0.5-1.25

0.22

0.17

0.90

0.30

0.14-0.20

0.23
0.23

0.17

0.25

7.00

-

Achromat

3.90

0.40

3.10

1.2

DL 40X

0.65

0.65

0.17

0.55
1.25
0.25

2.7-1.7
0.23
6.10

0.17

6.20

1.2

3.10

1.2

0.55

2.10

1.2

LWD ADL 40XC

0.55
0.25

7.00

-

0.40

3.90

0.17

P 40X

0.65

0.65

0.17

P 100XH

1.25

0.23

0.17

0.04

3.20

-

UW 2X

0.06

7.50

-

4X

0.10

30.00

-

Brightfield

10X

0.25

10.50

-

(CFI Plan)

20X

Plan Achromat

0.65

0.56

0.17
0.17

50XH

0.90

0.35

-

100XH

1.25

0.20

0.17

No Cover

NCG 40X

0.65

0.48

0

(CFI Plan)

NCG 100X

0.90

0.26

0

(CFI Plan)

DL 10X

0.25

10.50

-

DL 20X

0.40

1.20

0.17

DL 40X

0.65

0.56

0.17

DL 100XH

1.25

0.20

0.17

Fluor
Super Fluor

10XW

0.30

2.00

0

Epi-fl

20XW

0.50

2.00

0

(CFI Fluor)

40XW

0.80

2.00

0

60XW

1.00

2.00

0

4X

0.20

15.5

-

10X

0.50

1.20

0.17

20X

0.75

1.00

0.17

(CFI S Fluor) 40X

0.90

0.30

0.11-0.23

1.30

0.22

0.17

0.5-1.3

0.20

0.17

Epi-fl

40XH
100XH( iris)

Plan Apochromat

UW 1X

40X

0.2

0.17

0.2

0.17

DL 4X

0.13

16.40

1.2

DL 10X

0.30

15.20

1.2

DLL 10X

0.30

16.00

-

(CFI Plan Fluor) DLL 20X
DLL 40X

0.50

2.10

0.17

-

LWD P 20X

1.20

1.30
0.5-1.3

0-2.0

P 10X

0.40

100XH

Phase
Contrast

-

0.40

30.00

100X
100XH ( iris )

0.17

0.25

0.10

60XSH ( iris )

0-2.0

ADL 10X
New Phase LWD ADL 20XF
Contrast
LWD ADL 40XF
(CFI)

2.7-1.7

60X

Plan Fluor

0.5-1.25
0.40

LWD DL 40XC

Epi-fl

(CFI Plan Fluor) 40XH

0.17

LWD DL 20XF

P 4X

10

1.25

LWD DL 20X

BM 10XA

Phase
Contrast

N.A.

0.65

DL 100XH

(CFI)

Name

40X

DL 10X

Polarizing

Use

LWD 20X

100XH( iris)

(CFI)

Cover-glass
Thickness

W.D.
(mm)

100XH

Phase
Contrast

W.D.
(mm)

N.A.

Name

Cover-glass
Thickness

Type

Type

Use

0.75

0.72

0.17

DLL 100XH

1.30

0.20

0.17

2X

0.10

8.50

-

4X

0.20

15.70

-

10X

0.45

4.00

0.17

20X

0.75

1.00

0.17

40X

0.95

0.14

0.11-0.23

Brightfield

40XH

1.00

0.16

0.17

(CFI Plan Apo)

60X

0.95

0.15

0.11-0.23

Evanescent

60XH

1.40

0.21

0.17

VC 60XH

1.40

0.13

0.17

VC 60XWI

1.20

0.27

0.15-0.18

VC 100XH

1.40

0.13

0.17

NCG 100XH

1.40

0.17

0

TIRF 60XH

1.45

0.13

0.10-0.22

1.45

0.13

0.17

DM 20X

0.75

1.00

0.17

DM 40X

0.95

0.14

0.11-0.23

DM 40XH

1.00

0.16

0.17

DM 60X

0.95

0.15

0.11-0.23

TIRF
(CFI Plan Apo) TIRF 100XH

Phase
Contrast
(CFI Plan Apo)

DM 60XH

1.40

0.13

0.17

DM 100XH

1.40

0.13

0.17

90i/80i Specifications

Eclipse 90i/80i Specifications
90i
Main Body

Optical system
Base
Illumination

80i

CFI60 infinity optical system
Mechanical stage model / Rotatable stage model
Precentered 12V100W halogen transmitted illumination
Built-in fly-eye lens
Built-in NCB11/ ND8/ ND32 filters (detachable ) &
diffuser (not detachable)
Preset switch
Motorized field diaphragm
External power supply
Motorized ND filter unit for light intensity control

Precentered 12V100W halogen transmitted illumination
Built-in fly-eye lens
Built-in NCB11/ ND8/ ND32 filters (detachable ) & diffuser
(not detachable)
Preset switch
Built-in power supply

available as option
Focusing

Motorized coaxial coarse/fine/super-fine focusing
Built-in linear encoder, resolution : 0.05um
Focusing stroke : 27mm
Escape function as refocusing mechanism
Auto Link Focus

Manual coaxial coarse/fine focusing
Focusing stroke : 27mm
Coarse : 14mm/rotation, Fine : 0.1mm/rotation
Minimum reading : 1um
Refocusing mechanism with focus clamp
Coarse motion torque adjustable

Eyepiece Tube
(Light distribution)

Y-TB Binocular Tube F.O.V. 22
Y-TF Trinocular Tube F UW F.O.V. 22/25mm (Eyepiece/Port : 100/0, 0/100)
Y-TT Trinocular Tube T UW F.O.V. 22/25mm (Eyepiece/Port : 100/0, 20/80, 0/100)
C-TE Ergonomic Binocular Tube F.O.V. 22mm inclination angle : 10-30 tube extension up to 40mm
(when C-TEP DSC port is attached: Eyepiece/Port 100/0, 50/50
D-DH Digital Imaging Head / D-DH-E Motorized Digital Imaging Head F.O.V. 22/25mm
(Eyepiece/Front Port/Rear Port : 100/0/0/, 0/100/0, 0/0/100*)

* A 30/0/70 type is also available for DIH-M.

Eyepiece Lens
(F.O.V.)

10X (22mm), 10X M photomask (25mm), 12.5X (16mm), 15X (14.5),
UW10X (25mm), UW 10X M photomask (25mm)

Nosepiece

D-N7-E Motorized Septuple Nosepiece
D-ND6-E Motorized Sextuple DIC Nosepiece
D-NI7 Intelligent Septuple Nosepiece
D-NID6 Intelligent Sextuple DIC Nosepiece

D-NI7 Intelligent Septuple Nosepiece
D-NID6 Intelligent Sextuple DIC Nosepiece
C-N Sextuple Nosepiece
D-ND6 Sextuple DIC Nosepiece

C-N Sextuple Nosepiece, D-ND6 Sextuple DIC Nosepiece
Stage

C-SRR Rotatable Rectangular Mechanical Stage
(Ball bearing mechanism)
Cross travel 78(X) x 54(Y) mm, with calibrations,
stage handle height and torque adjustable, rackless
D-S-E Motorized XY Stage
Cross travel 78(X) x 54(Y) mm, Repeatability : ±10µm

C-SRR Rotatable Rectangular Mechanical Stage
(Centerable, rotation angle 220˚)
C-SR Rectangular Mechanical Stage
Cross travel 78(X) x 54(Y) mm, with calibrations,
Stay-in -position stage handle height and torque adjustable, rackless
C-HC1/HL2 Specimen Holders for 1 slide/2 slides

C-HC1/HL2 Specimen Holders for 1 slide/2 slides
Condenser

D-CUD-E Motorized Universal Condenser Dry
(Motorized 7-position turret and aperture diaphragm),
D-CUD Universal Dry, D-CUO DIC Oil,
C-C Abbe, C-C Achromat, C-C Achromat Swing-out 1-100X,

D-CUD Universal Dry, D-CUO DIC Oil,
C-C Abbe, C-C Achromat, C-C Achromat Swing-out 1-100X,
C-C Low Power, C-C Achromat/Aplanat,
C-C Phase Contrast, Darkfield (Dry/Oil), LWD Achromat

C-C Low Power, C-C Achromat/Aplanat,
Darkfield (Dry/Oil), LWD Achromat
Power Consumption (max.)
Weight (approx.)

100-230V, 2.8A/210W

100-230V, 2.4A/170W

18.2 kg (standard trinocular set)
11

Digital-imaging Heads, Universal Epi-fluorescence Illuminator Specifications
DIH-E

DIH-M

Universal Epi-fluorescence Illuminator

Applications

Epi-fluorescence, Epi-brightfield, Epi-darkfield, Epi-DIC, Epi-simple polarizing, Confocal

Light distribution

Observation/front port/rear port: 100/0/0, 0/100/0, 0/0/100

100/0/0, 0/100/0, 0/0/100 *
* A 30/0/70 type is also available.

Motorized switching
Optical output ports

Depends on eyepiece tube used

Manual switching

Font port: 1X, diameter ø52mm
Rear port: optical zoom 0.8-2.0X (continuous), zoom ratio 2.5 : 1, C-mount
Motorized

Not available

Manual

Inclination angle

25°

F.O.V.

22, 25mm

Filter turret

6 filter cubes mountable

Depends on eyepiece tube used

Motorized

Manual

Hi S/N Noise Terminator mechanism

Available

Excitation light balancer

Available

Aperture diaphragm

Centerable, detachable, diameter ø1-9mm (manual)

Field diaphragm

Centerable, not detachable, diameter ø1-9mm
Motorized

Manual

ND filters

ND4, ND8, ND16 (manual)

Excitation light shutter

Motorized

Analyzer

Motorized

Polarizer

Manual (with slot)

Light source

Mercury, xenon, halogen (centerable)

External connection

USB, C1 interlock, external connection connector

Not available

Status-check function

Available (data can be recorded with image captured by Digital Sight digital camera)

Not available

Compatible microscopes

90i, 80i

90i, 80i, E600, E600FN, ME600L, L150

Manual
Manual (with slot)

Specifications and equipment are subject to change without any notice
or obligation on the part of the manufacturer. January 2005.
©2004 NIKON CORPORATION
WARNING

TO ENSURE CORRECT USAGE, READ THE CORRESPONDING
MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.

Company names and product names appearing in this brochure are their registered
trademarks or trademarks.

NIKON INSTECH CO., LTD.

NIKON INSTRUMENTS EUROPE B.V.

NIKON INSTRUMENTS INC.

Parale Mitsui Bldg., 8, Higashida-cho, Kawasaki-ku,
Kawasaki, Kanagawa 210-0005, Japan
phone: +81-44-223-2167 fax: +81-44-223-2182
www.nikon-instruments.jp/eng/

P.O. Box 222, 1170 AE Badhoevedorp, The Netherlands
phone: +31-20-44-96-222 fax: +31-20-44-96-298
www.nikon-instruments.com/

1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.
phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A.only) fax: +1-631-547-0306
www.nikonusa.com/

NIKON FRANCE S.A.S.
FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33
NIKON GMBH
GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322
NIKON INSTRUMENTS S.p.A.
ITALY phone: + 39-55-3009601 fax: + 39-55-300993
NIKON AG
SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861
NIKON UK LTD.
UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-4584

NIKON CANADA INC.
CANADA phone: +1-905-625-9910 fax: +1-905-625-0103

NIKON INSTRUMENTS (SHANGHAI) CO., LTD.
CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030
(Beijing office)
CHINA phone: +86-10-5869-2255 fax: +86-10-5869-2277
NIKON SINGAPORE PTE LTD
SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668
NIKON MALAYSIA SDN. BHD.
MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387

NIKON CORPORATION
Fuji Bldg., 2-3, Marunouchi 3-chome, Chiyoda-ku,
Tokyo 100-8331, Japan
www.nikon.com/
Printed in Japan (0501-10)T

Code No. 2CE-MSLH-2

This brochure is printed on recycled paper made from 40% used material.

En



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Create Date                     : 2004:12:27 04:09:30Z
Modify Date                     : 2006:10:20 10:34:59+01:00
Metadata Date                   : 2006:10:20 10:34:59+01:00
Creator Tool                    : QuarkXPress. 4.10r2: AdobePS 8.7.2 (104)
Format                          : application/pdf
Creator                         : nakata
Title                           : 90i/80iiE_Accessories
Document ID                     : uuid:ea4ce8ba-800b-4e49-8b5d-573b86c3f476
Instance ID                     : uuid:052c72b5-6977-45f8-9a76-11fed2656d0f
Has XFA                         : No
Page Count                      : 12
Author                          : nakata
EXIF Metadata provided by EXIF.tools

Navigation menu