Nokia Solutions and Networks CPE25400 Non-Line-of-Sight Fixed Wireless Data Link User Manual 5B Hardware Installation 68P09287A82 B

Nokia Solutions and Networks Non-Line-of-Sight Fixed Wireless Data Link 5B Hardware Installation 68P09287A82 B

Contents

5B Hardware Installation 68P09287A82 B

CPEo 400 SERIES INSTALLATION Motorola recommends installing the external Ethernet cable in accordance with the latest revision of the National Electrical Code (NEC) and/or all country and local electrical codes to provide some protection against damage caused by near-miss lightning strikes and other electrical discharges.Note: The Ethernet port is used for both power and data.1.  Mount the CPE unit by following and referring to figures 2 and 4. Do NOT tighten the set screws/bolts.  Site configuration      determines if the CPE unit is mounted on a pole or a wall.2.  Mount the Surge Suppressor according to the manufacturer’s instructions.3.  Connect ground cable from CPE unit to ground.4.  Attach the boot on the outdoor Ethernet cable connector as shown in figures 1 and 3.  Then connect that outdoor Ethernet      cable between the surge suppressor and the CPE unit.5.  Connect an outdoor Ethernet cable between the Connector Box (To Radio) and the Surge Suppressor. (Refer to Figure 1.)6.  Connect the AC power cord to the Power Adapter and then to the AC outlet/power source.  (Refer to Figure 1.) 7.  Plug the end of the short ethernet cable (To computer) into the Ethernet port of your computer.  8.  Adjust CPE unit left/right and up/down until the interval of beeping is shortest or a constant tone.  Tighten the set screws     to hold the CPE unit in position.9.  At your computer, open your browser and enter http://mywimax. (With a dot at the end) into the address field and press the     Enter key.  A wizard will start up to guide you through the configuration.10. Follow the directions in the wizard to complete the configuration.11. Navigate the browser to Control Panel>System and disable the buzzer.  The unit will stop beeping.HARDWARE INSTALLATION PROCEDURE6445733561AC Power CordAC Power AdaptorGroundCPE UnitBoot Attached HereComputerBlack = Motorola SuppliedBlue = Installer SuppliedAC OutletSurge Suppressor2Figure 1● Adjustable Wrench● Two outdoor Ethernet cables● Surge Suppressor (if required)● Cross recessed screwdriver● Ground cableINSTALLER SUPPLIED ITEMSMOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of theirrespective owners. © Motorola, Inc., 2007. 68P09287A82-B68P09287A82-BConnected to Wall – AssembledFigure 2Connected to Pole – Assembled
Motorola, Inc.Consumer Advocacy Office1307 East Algonquin RoadSchaumburg, IL 60196www.motorola.com1-800-555-1212 (United States)1-888-555-1212 (TTY/TDD United States for hearing impaired)1-800-555-1212 (Canada)PARTS LISTCPEo 400 Series15131214132111110 610 67    Set Screw13 41213128912 1437    Set Screw101611213514Figure 410Figure 3Boot AssemblyCableSealing NutSealsScrew NutHousingRJ45 PlugGasket

Navigation menu