Nokia Solutions and Networks MMDS-CPE6 Non-Line of Site Wireless Data Link User Manual InstallExternalOSU

Nokia Solutions and Networks Non-Line of Site Wireless Data Link InstallExternalOSU

Contents

Manual

iInstalling and using the Expedience Outdoor Subscriber Unit (OSU)Broadband Wireless Access SystemThis document is intended for use by professional equipment installers. Subscribers of the high speed Internet service should not attempt to install the OSU.Part Number:104-0009-0001-03
iiExpedience and LinkMonitor are trademarks of NextNet Wireless, Inc.Other brand and product names may be registered trademarks or trademarks of their respective holders. Part number: 104-0009-0001-03©2002-2003 NextNet Wireless, Inc. All rights reserved.THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS GUIDE ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS GUIDE ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCT.FOR WARRANTY INFORMATION ON THE EXPEDIENCE OSU, CONTACT THE INTERNET SERVICE PROVIDER THAT SUPPLIED THE OSU.NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE THAT ARE PROVIDED ON THE EXPEDIENCE BROADBAND WIRELESS ACCESS MODEM CD-ROM ARE PROVIDED “AS IS” WITH ALL FAULTS. NEXTNET WIRELESS DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.IN NO EVENT SHALL NEXTNET WIRELESS OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OF DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS GUIDE, EVEN IF NEXTNET WIRELESS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
iiiCONTENTSWelcome ..............................................................................................1Before you begin ..................................................................................1Additional material required for installation .....................................................1Pre-installation planning  ......................................................................................2Connecting the OSU to a computer ................................................... 3Installation overview .............................................................................................3Cabling overview ...................................................................................................4Installing the OSU .............................................................................. 5Selecting an installation location for the OSU ..................................................5Installation overview .............................................................................................5Attach the mounting bracket to the outside of the building ..........................6Setting the OSU inside the mounting bracket ..................................................8Partially tightening adjustment screws to hold OSU in place  ........................8Running cables through building’s wall  ...........................................10Attaching the NIM box to the outside of building  ........................... 10Plugging cables into NIM box .......................................................... 11Connecting ground wires  .................................................................. 12Plugging in power cord and RJ-45 cord ............................................13(Optional) Finding the strongest service provider signal ................. 13Installing the LinkMonitor program  ................................................................13Using the software-assisted method to find the strongest signal  ................14Using the sound (auditory) method to find the strongest signal  .................15Setting up the computer to receive an IP address  ............................15Configuring IP address assignment for routers ................................17Connecting to the Internet  ................................................................17Refreshing the OSU’s connection  .....................................................17Windows users: Refreshing the connection ....................................................17Non-Windows users: Refreshing the connection ..........................................17Connecting the OSU to a network  .................................................... 17FCC information ................................................................................ 19
iv Installing and using the Expedience OSU
1WelcomeThis document describes how to install and use the Expedience outdoor subscriber unit (OSU) to obtain wireless high-speed Internet access. Subscribers can connect the OSU to a computer or to a small office/home office (SOHO) local area network (LAN) through a hub, switch, or router.This document is intended for use by professional equipment installers. Subscribers of the high-speed Internet service should not attempt to install the OSU. For questions about OSU operation or installation, subscribers should contact the ISP that supplied the OSU device. Before you beginThis section describes items the installer or subscriber must purchase before the OSU is installed. This section also describes items you need to have available and things to consider before beginning the OSU installation.Additional material required for installation• The subscriber’s computer must be equipped with an Ethernet network interface card (NIC). The NIC is not provided with the OSU, but subscribers can purchase a NIC at most computer and electronics stores.• An RJ-45 Ethernet cable. This cable must be an outdoor rated, TIA/EIA category 5 Ethernet cable. The length of this cable depends on where you plan to install the Network Interface Manager (NIM) box on the building and where the computer (or hub) is placed inside the building.• Ground wire of sufficient length to run between the OSU and a ground rod. Also, you need to obtain ground wire to run between the NIM box and the ground rod.• It is recommended that the ground wire be an 8 AWG, solid aluminum or copper wire.• It is recommended that the ground rod used be 8 feet (2.5 m) copper. Note that most buildings have an existing ground rod outside, at the main power connection site. If desired, you can install a rod into the ground outside the building. • OSU to NIM box communication cable. Four lengths of cable are available. Select the cable length appropriate to the OSU installation location. Table 1 lists the cable lengths you can order and use.• Anti-seize compound to be applied to the stainless steel screws that hold the OSU to the mounting bracket.• If you mount the OSU or NIM box on a brick or masonry surface, lead screw anchors are required. Table 1 OSU communication cablesCable Part number25 feet (7.5 m) 597-6020-002550 feet (15 m) 597-6020-005075 feet (22.5 m) 597-6020-0075100 feet (30 m) 597-6020-0100
2Installing and using the Expedience OSUPre-installation planning• Find an appropriate location on the outside of the building to mount OSU. • To provide Internet service, the OSU communicates with a base station on the service provider’s communications tower. The service provider must provide you with information about the nearest communications tower. For example, if the tower nearest to the building is north of the building, you will install the OSU on the north side of the building.• Mount the OSU on a high location on the building, such as under the eaves. • Find an appropriate location on the outside of the building to mount the NIM box.• Locate the components shipped with the OSU device. Table 2 lists these components.Table 2 OSU package componentsComponent Part number QuantityOSU device (vertical) 900-0055-1000 1—OR—OSU device (horizontal) 900-0055-2000 1Mounting bracket 350-0009-0010 11/4 X 2" lag bolt, hex HD, grade 2 Galv. 594-9907-1464 41/4-20X.875 bolt, hex HD, SS 594-9909-1428 2Self-drilling hex head 10 X 1.5 594-2909-1048 21/4 split lock washer, SS 596-3003-1416 31/4 flat washer, SS 596-3004-1420 7Double tab washer 596-3099-1416 1External OSU network interface box 123-0009-0055 1Power supply (home to NIM) 420-0010-1010 1Power cord  597-5120-0107 1Wire tie 593-0005-0032 1OSU Installation Guide 104-0009-0001 1Installation software CD-ROM 110-0002-0001 1
3Figure 3 illustrates the OSU package contents. Components are not to scale.Connecting the OSU to a computerThis section describes how to connect the OSU to a computer. If the OSU is to be connected to a network device (such as a router or switch), refer to the section “Connecting the OSU to a network” on page 17, in this guide. Installation overviewThe installation consists of the following major tasks, each of which is explained in greater detail in the sections that follow:1Attach the OSU to the outside of the building.2Run the power cable and the RJ-45 Ethernet cable through a hole drilled through the building’s wall.Figure 3 OSU package contentsNetwork interface boxSoftware CD-ROMPower supplyOSUInstallOSU Installation GuideOSUMounting bracketDouble tab washer (1)Flat washer (7)Split lock washer (3)Power cableLag bolt (4)Hex screw (2)Self-drilling hex screw (2)
4Installing and using the Expedience OSU3Mount the NIM box to the outside of the building.4Connect the cables into the NIM box.5Connect the ground wires.6Connect the power cord to standard household power. Connect the RJ-45 Ethernet cable.7Adjust the OSU to obtain the strongest service provider signal.8Ensure that the computer is set up to automatically obtain an IP address.9Connect to the Internet.Cabling overviewFigure 4 illustrates the routing of the ground wires, the RJ-45 Ethernet cable, the power cord, and the OSU communication cable. Note: The ground wire, RJ-45 cable, anti-seize compound for the hex screws, and computer NIC are not supplied with the system.Figure 4 Connecting cables overviewBuilding’s roofBuilding’s wallOSU bracket mounted tobuilding's exteriorNIM boxto grounding rodPower supplyEthernet cable (not supplied)Subscriber’s computerGround wireOSU communication cablemounted tobuilding’s exterior(not supplied)(not supplied)
5Installing the OSUThis section describes how to find an appropriate installation location for the OSU and how to install the OSU on the building. Selecting an installation location for the OSUIt is recommended that you determine the optimum installation location for the OSU before physically mounting the OSU and NIM box to the building.To do so, use a residential subscriber unit (RSU). The RSU can detect where a signal from the service provider can be received at the installation site. Most often if you mount the OSU on the side of the building facing the service provider's base station, the OSU can detect adequate signal in order to provide high-speed Internet access. However, unless there is an obvious line of sight to the correct base station, the correct orientation of the OSU is often not apparent. There also may be practical reasons why you cannot mount the OSU on the side the building that faces the base station. To use the RSU to determine where you might be able to install the OSU on the building, point the back of the RSU in various directions around the installation site. The back of the RSU is the side without logos. At each direction you point the RSU, note the number of blinking lights on top of the RSU. The stronger the signal that the RSU can detect, the more lights blink on and off. After determining where signal can be detected around the building, you can then choose a corresponding OSU installation location on the building. As you attach the OSU to the building, make sure to point it in the same direction that the RSU was pointed when the RSU detected a signal. Note: When detecting signal at the site, you must use an RSU that has the same vertical or horizontal polarization as the OSU to be installed. For further instructions on how to use the RSU to detect service provider signal, refer to the Expedience Broadband Wireless Modem User Manual for the RSU. You can find an electronic version of this document on the software CD supplied with the OSU.For further information about additional procedures you can use to further optimize the OSU installation, refer to the section “(Optional) Finding the strongest service provider signal” on page 13 in this guide.Installation overviewTo install the OSU:1Attach the mounting bracket to the outside of the building.2Set the OSU inside the mounting bracket.3Tighten the lower mounting bolt to hold the OSU in place. The following sections describe these steps in greater detail.
6Installing and using the Expedience OSUAttach the mounting bracket to the outside of the building1Where possible, install the OSU on the side of the building that has the greatest exposure to the communications tower of the service provider. The service provider can provide information about tower locations that can provide the OSU with greatest signal exposure. 2Install the mounting bracket to the building. The bracket (like the OSU) must be installed vertically. • Drill the two top holes 1.25 inches (3.2 cm) apart. Drill the bottom holes 7 inches (18 cm) below the top holes. Figure 6 provides a template for drilling the holes. • If possible, drill one upper hole and its corresponding lower hole into a stud. Do not allow the OSU to be supported by the building’s siding only. • If installing the OSU on a brick or masonry surface, use lead screw anchors.• After the holes are drilled into the building, drive the screws (illustrated in Figure 5) through the holes on the mounting bracket and into the building. Figure 5 illustrates the screws to use to attach the mounting bracket to the building. Figure 5 Screws to attach mounting bracket to building
7Figure 6 provides dimensions for drilling holes into the side of the building.Figure 6 Mounting bracket dimensions2X 1.252X 7.00
8Installing and using the Expedience OSUSetting the OSU inside the mounting bracketThe OSU must be installed vertically. The OSU has a peg on top, and a peg on bottom. The upper and lower pegs snap into the mounting bracket’s peg holes.You must install the OSU vertically. To install the OSU in the mounting bracket:1Make sure the bottom of the OSU faces the earth. This is the side of the OSU labelled with a sticker “MOUNT THIS SIDE DOWN”. The sticker is illustrated in Figure 8.2On the bottom arm of the mounting bracket, snap the OSU’s peg into the peg hole. 3On the top arm of the mounting bracket, snap the OSU’s upper peg into the adjustment arch. To accommodate the height of the peg, you may need to lift the mounting bracket’s edge up slightly.Partially tightening adjustment screws to hold OSU in placeTo make sure the OSU doesn’t slip out of the mounting bracket, partially tighten the screws in the adjustment arch.If you still need to pivot the OSU along the adjustment arch—in order to find the strongest signal from the service provider—do not fully tighten the screws yet. You will fully tighten the screws after finding the strongest signal from the service provider. When the screws are fully tightened, the OSU will no longer move along the adjustment arch.Note: Before mounting the OSU in the bracket, apply an anti-seize compound to the screws used in the assembly. Figure 7 Adjustment arch and peg hole in mounting bracketFigure 8 MOUNT THIS SIDE DOWN StickerAdjustment archPeg holeMOUNT THISSIDE DOWN
9Figure 9 illustrates how the screw, split lock, flat washer and double-tab washer are put together.1For the top of the mounting bracket, assemble the screw (coated with anti-seize compound), split lock washer and flat washer as shown in Figure 9.2For the bottom of the mounting bracket, assemble the screw (coated with anti-seize compound), split lock washer, flat washer, ground wire, and double-tab washer, as shown in Figure 9.Let the ground wire dangle to the ground. 3On the upper arm of the mounting bracket, insert the screw through the adjustment arch on the mounting bracket. 4Partially tighten the screw on the OSU to hold it in place.5On the bottom are of the mounting bracket, partially tighten the bolt on the bottom of the OSU. 6Plug in the circular end of the OSU communication cable in the bottom of the OSU. Provide strain relief by making a loop in the cable and strapping it to the lower part of the mounting bracket. Figure 9 Mounting bracket screw assemblyScrew, coated withSplit lock washerFlat washerBracketSolid ground wireSplit lock washerFlat washerDouble tab washerScrew, coated withTop of unitBottom of unitanti-seize compoundanti-seize compound
10 Installing and using the Expedience OSUNote: You will fully tighten both bolts in the section, “(Optional) Finding the strongest service provider signal” on page 13.Running cables through building’s wallThe power cable and Ethernet cable run from inside the building to the NIM box, which you will install in step 3.1Near the NIM box, drill a 3/4 inch (18 mm) hole through the wall. 2Draw one end of the RJ-45 cable through the hole. 3Draw the power cable through the hole. 4Mount the power supply to the inside wall of the building. (Screws not provided.)5Seal the hole with caulking material after completing the installation. Attaching the NIM box to the outside of buildingTo attach the NIM to the outside of the building:1Make sure the bottom of the NIM is facing the ground. A rubber grommet is installed on the bottom of the NIM.2The screws provided with the NIM are self-drilling.• Drive the upper screw through the opening in the upper bracket and into the side of the building.• Drive the lower screw through the opening in the lower bracket and into the side of the building. • Make sure at least one screw is set into a stud in the wall.• If installing the NIM box on a brick or masonry surface, use lead screw anchors.Figure 10 Screws to attach NIM box to building
11Figure 11 illustrates where to drive the screws through the NIM box brackets and into the side of the building. Plugging cables into NIM boxYou must connect cables into the NIM box in the order shown below. Failure to connect the cable in the proper order makes it difficult to run the cables through the rubber grommet on the bottom of the NIM box.It is recommended that you use a gel sealant around the grommet. 1Connect the OSU communication cable into the NIM box. This is the cable that runs from the NIM box to the OSU device. 2Plug in the RJ-45 Ethernet cable.3Plug in the power supply cable. This is the cable that runs from the power supply in your building to the NIM box.4Inside the NIM box, wire tie the power cable, RJ-45 cable, and ground wire together. Also, wire tie all the cables and ground wire together on the outside of the NIM box. Note: Do not plug in the power cable to the indoor power supply yet.Figure 11 Mounting NIM to building’s exteriorDrive screwthrough upper bracket Drive screw through lower bracket
12 Installing and using the Expedience OSUFigure 12 shows the cables and the ground wire connected inside the NIM box. Connecting ground wiresBoth the OSU and the NIM box must be grounded to a ground rod in the earth near your building. Make sure your ground cable does not exceed a 50 feet maximum to the ground rod.To ground the NIM box and the OSU:1Inside the NIM box, unscrew the hex nut labelled GND. 2Insert one end of the ground wire through the rubber grommet on the bottom of the NIM box. (Make sure you are NOT using the ground wire from the OSU. Rather, use a separate ground wire to ground the NIM.)3Loop the ground wire around the ground post. 4Re-tighten the hex nut around the wire to hold it in place.5Connect the other end of the ground wire to the ground rod in the ground next to the building.6Connect the ground wire from the OSU to the ground rod in the ground next to the building.7Attach all wires to the building by using electrical staples. Use drip loops as needed. 8Caulk the hole in the building with a silicone or acrylic caulk.Figure 12 Cables and ground wire plugged into NIM boxPower cableOSU communication cableGround wireRJ-45 cableCable ties
13Plugging in power cord and RJ-45 cord1Plug the RJ-45 cord into the NIC on your computer or switching device.2The power cord uses standard household power. Plug the power cord in the power source.(Optional) Finding the strongest service provider signalNote: The following sections describe additional methods of optimizing the orientation of the OSU, if necessary. The OSU is equipped with an internal antenna. To provide the best service, the OSU searches for the strongest signal transmitted by your service provider.You can find the strongest signal from your service provider by using one of the following methods:• Software-assisted method• Sound (auditory) methodBoth methods require you to install the LinkMonitor programInstalling the LinkMonitor program1Locate the software CD supplied with your OSU. 2Insert the CD into your computer’s CD drive. If the installation program does not start automatically, start it by clicking on the Setup.exe icon.3Follow the instructions in the dialog boxes to complete the installation of the LinkMonitor program.4After the software is installed, a blue RSU icon appears in your computer’s system tray.To run the LinkMonitor program, right click on the icon, and select Open.Figure 13 Starting the LinkMonitor programLinkMonitor program’s icon in system tray
14 Installing and using the Expedience OSUThe Expedience LinkMonitor window appears (Figure 14).Using the software-assisted method to find the strongest signalNote: It may be beneficial to have two people perform this procedure. One person will monitor software statistics inside the building. The other person will rotate the OSU outside the building.To scan for the strongest signal from your service provider:1Install the LinkMonitor program as described in the section “Installing the LinkMonitor program” on page 13. 2On the LinkMonitor window, click Start Scan. 3Return to the OSU on the side of the building. 4Slowly rotate the OSU along the adjustment arch. Stop the rotation at every 15 degrees for 5 seconds. Note the score reported by the LinkMonitor program, as described in step 5. 5The LinkMonitor program searches for a signal from your service provider. In the Channel Score group, the strength of the signal received at the starting position is indicated in two ways:• The indicator bar shows varying levels of red, yellow, and green. Red indicates weak signal strength, yellow indicates moderate signal strength, and green indicates strong signal strength.•The Current Score field shows the signal strength. During this procedure, the program compares the Current Score to the Best Score. Best Score indicates the strongest signal the program has ever seen during the scanning procedure.Figure 14 Expedience LinkMonitor window
156Remembering the strongest signal reported, re-orient the front of the OSU in the direction that the OSU was pointed when the strongest signal was found.7Tighten the screws fully that hold the OSU in place. 8Return to the LinkMonitor program. Click Stop Scan. Using the sound (auditory) method to find the strongest signalTo use the sound (auditory) method to find the strongest signal:1Install the LinkMonitor program as described in the section “Installing the LinkMonitor program” on page 13. 2On the LinkMonitor window, click Start Scan.3Return to the OSU outside. You should hear the OSU beeping. • The OSU uses beeps to indicate the strength of the signal that the OSU can detect. The strength of the signal detected is indicated by the frequency of the beeps as compared to the pause between beeps. A constant beep with no pause indicates that a strong signal is detected by the OSU. One beep followed by a long pause indicates that a signal can be found, two beeps followed by a shorter pause indicates that a stronger signal is detected, and so on. • If the unit beeps twice, then pauses, then beeps twice, and so on, this indicates that the unit is scanning for service. If this beeping pattern is not broken, this indicates that the OSU cannot detect a signal. 4Rotate the OSU along the adjustment arch, noting how frequently the OSU beeps. 5Point the OSU in the direction where the beeps are most constant. 6Tighten the screws. 7Return to the LinkMonitor program and click Stop Scan.Setting up the computer to receive an IP addressThis section describes how to set up various Windows operating systems that might run on the host computer so that the computer can receive an IP address.You can set up the host computer or router so it can dynamically receive an IP address. If desired, the subscriber can request a static IP address for the host computer or router.Note: If the subscriber uses a non-Windows operating system, check help file of the operating system. Most help files explain how to set up a system to use a static or dynamic IP address.Windows 95, Windows NT, Windows 98, Windows ME: Setting up the network connection1From the Start menu, select Settings. Then select Control Panel.2In the window that appears, double click the Network icon.3Select the TCP/IP entry for the NIC. 4Click Properties.5Select the IP Address tab.
16 Installing and using the Expedience OSU6Perform one of the following:• To set up the host computer to dynamically receive an IP address from the service provider, activate the Obtain an IP Address automatically radio button.• To set up the host computer to have a static IP address:a Activate the Use the following IP address radio button. bIn the Use the Following IP Address group, complete the fields, as appropriate. 7To close the windows, click OK.8Turn off your computer. Windows 2000: Setting up the network connection1From the Start menu, select Settings. Then select Network and Dial-up Connections.2Right click the connection you want to alter; that is, the name of your NIC. From the pop-up menu, select Properties. 3The Local Area Connection Properties window appears. Select the Internet Protocol (TCP/IP) item. Click Properties.4Perform one of the following:• To set up the host computer to dynamically receive an IP address from the service provider, activate the Obtain an IP Address automatically radio button.• To set up the host computer to have a static IP address:a Activate the Use the following IP address radio button. bIn the Use the Following IP Address group, complete the fields, as appropriate. 5To close the window, click OK. 6On the remaining open window, click OK again. 7Turn off your computer.Windows XP: Setting up the network connection1From the Start menu, select Settings. Then select Network Connections.2Right click the connection you want to alter; that is, the name of your NIC. From the pop-up menu, select Properties. 3The Local Area Connection Properties window appears. Select the Internet Protocol (TCP/IP) item. Click Properties.4Perform one of the following:• To set up the host computer to dynamically receive an IP address from the service provider, activate the Obtain an IP Address automatically radio button.• To set up the host computer to have a static IP address:a Activate the Use the following IP address radio button. bIn the Use the Following IP Address group, complete the fields, as appropriate. 5To close the window, click OK. 6On the remaining open window, click OK again. 7Turn off your computer.
17Configuring IP address assignment for routersFor instructions on how to assign a static IP address to a router, or to set up the router to use DHCP to receive an IP address, refer to the documentation that accompanied the device.Connecting to the InternetTo connect to the Internet:Start your Internet browser, and try to open a few Internet sites.• If you can open numerous sites, enjoy your new, high-speed service.• If yon cannot open any sites—for example if your browser displays a message “This page cannot be displayed” for all the sites you tried to access—refresh the OSU’s connection, as described in the section “Refreshing the OSU’s connection” on page 17.Refreshing the OSU’s connectionWhen you refresh the OSU’s connection, your service provider is assigning your computer a new IP address. You need to refresh your OSU’s connection with your service provider when your Internet browser does not let you open any Internet sites.Windows users: Refreshing the connectionThe OSU’s connection is refreshed when you restart the computer. To refresh the connection without restarting the computer:1Make sure you have installed the LinkMonitor program.2In the system tray, right click the blue RSU icon (Figure 13) and select Open. 3In the window that appears, on the Local Net Config tab, click the Renew IP Address button.Non-Windows users: Refreshing the connectionIf you do not run the Windows operating system, you can reboot your computer to refresh the connection. You may want to refer to your operating system’s help files to determine if other methods exist to refresh the connection (that is, to find a method for refreshing the IP address).Connecting the OSU to a networkNote: Use only one OSU on a network. Do not use multiple OSUs on the same network.To directly connect the OSU to a computer, use an Ethernet cable (also known as a straight-through cable).However, to connect the OSU to a hub or switch, use an Ethernet cable appropriate for your network device. This might be a straight through or cross-over cable, depending on how your
18 Installing and using the Expedience OSUnetwork device switches signals. When determining how to set up your network, remember that the OSU device operates as a hub or a bridge. After connecting the OSU to the network device, power the OSU and scan for a service provider signal, as described in earlier sections of this guide.
19FCC informationNOTICE: This equipment has been tested and found to comply with the Radio Frequency Radiation Exposure Limits detailed below. A minimum of 20 centimeters (8 inches) separation between the OSU and the operator and all other persons should be maintained.Radio Frequency Radiation Exposure Limitsf = frequency in MHz* = Plane-wave equivalent power densityNote: NOTE 1 to Table 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure.Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposureNote: NOTE 2 to Table 1: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure.Declaration of Conformity Compliance InformationClass B computer peripheralThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Table 1 Limits for Maximum Permissible Exposure (MPE)Frequency range (MHz)Electric field strength (V/m)Magnetic field strength (A/m)Power density (mW/cm2)Averaging time (minutes)(A) Limits for Occupational/Controlled Exposures0.3-3.0 614 1.63 *(100) 63.0-30 1842/f 4.89/f *(900/f2)630-300 61.4 0.163 1.0 6300-1500 — — f/300 61500-100,000 — — 5 6(B) Limits for General Population/Uncontrolled Exposure0.3-1.34 614 1.63 *(100) 301.34-30 824/f 2.19/f *(180/f2)3030-300 27.5 0.073 .2 30300-1500 — — f/1500 301500-100,000 — — 1.0 30
20 Installing and using the Expedience OSUResponsible Party: NextNet Wireless, Inc.9555 James Ave. South Suite 270Bloomington, MN 55431952-929-4008Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.Note: Modification of this device may void the user’s authority to operate the equipment.
21Aanti-seize compound 1Ccable diagram 4computerNIC requirement 1cross-over cable 17Gground wiresconnecting 12grounding rod 1grounding wirerecommended 1IIP addressrenewing 17IP address (host computer)refreshing 17LLANconnecting to OSU 17LinkMonitor program 13Mmounting bracketattaching to house 6drilling template 7screw assembly 9Nnetwork deviceconnecting to OSU 17NIC requirement 1NIM boxattaching to house 10choosing installation location 2grounding 1OOSUbottom 8choosing installation location 2connecting to network 17installing inside mounting bracket 8min. separation distance of equipment andpersons 19package components 1, 2Ppart numbers list 1, 2power cordrunning through house 10RRJ-45 cableplugging in 13running through house 10routerconnecting to OSU 17Sservice provider signalfinding strongest 13switchconnecting to OSU 17INDEX
22 Installing and using the Expedience OSU