Nokia of America BBTRX-07 Light Radio-9768 Metro Radio Outdoor User Manual Exhibit D Users Manual per 2 1033 c3

Alcatel-Lucent USA Inc. Light Radio-9768 Metro Radio Outdoor Exhibit D Users Manual per 2 1033 c3

Exhibit D Users Manual per 2 1033 c3

APPLICANT:  Alcatel-Lucent                                                                                                        FCC ID:  AS5BBTRX-07      Section 2.1033(C)(3)  USERS MANUAL                   Alcatel-Lucent Use pursuant to Company Instructions
APPLICANT:  Alcatel-Lucent                                                                                                        FCC ID:  AS5BBTRX-07    USERS MANUAL SECTION 2.1033(c) (3)   A  copy of the installation and operating instructions to be furnished the user.  A draft copy of the instructions may be submitted if the actual document is not available.  The actual document shall be furnished to FCC when it becomes available.   RESPONSE:   A copy of   (1) Light Radio Metro outdoor Installation Manual  is attached.                                                                                                                                                                                                                                                                                                                                                                                                                                          Alcatel-Lucent Use pursuant to Company Instructions
PRELIMINARY PRELIMINARY              Alcatel-Lucent 9768 lightRadio™ Metro Radio Outdoor V1.0 B13  Installation 3MN-01751-0002-RJZZA September 2012                  Alcatel-Lucent – Proprietary Use pursuant to applicable agreements
PRELIMINARY PRELIMINARY Legal notice  Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.  The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright © 2012 Alcatel-Lucent. All rights reserved. Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside Alcatel-Lucent without its written authorization.  Not to be used or disclosed except in accordance with applicable agreements.
PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY      About this document  Purpose ............................................................................................................................................................................................. Supported systems ........................................................................................................................................................................ Safety information .............................................................................................................................................................................  1  Safety  Structure of safety statements ............................................................................................................................................... 1-1  General safety considerations ............................................................................................................................................... 1-2  Specific safety hazards and RF Safety Statements........................................................................................................ 1-3   2  Metro Radio Outdoor features  Power ............................................................................................................................................................................................. 2-2  Physical properties ................................................................................................................................................................... 2-3  3  Installing an 9768 MRO  Procedure 3-1: Installing the 9768 MRO onto a wall or pole ...................................................................................  3-1   A  Product conformance statements  RoHS compliance .................................................................................................................................................................... A-1  General safety ........................................................................................................................................................................... A-1  Emissions .................................................................................................................................................................................... A-1  AC power supply conformance .......................................................................................................................................... A-3   B  Other statements  Product safety ............................................................................................................................................................................ B-1   Glossary  Index
List of tables ....................................................................................................................................................................................................................................                Alcatel-Lucent – Proprietary                             9768 lR MRO V1.0 B13 Use pursuant to applicable agreements                                     3MN-01751-0002-RJZZA                        September 2012  PRELIMINARY PRELIMINARY      1 RF safe distances for different power levels.................................................................................................... 1-2  2 AC power system wiring color codes ................................................................................................................ 2-1  3 List of major components and subassemblies..................................................................................................3-1
List of figures 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 1-1   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY     2-1   Form factor .................................................................................................................................................................. 2-3  2-2       Front view and side view of the drill hole pattern ......................................................................................... 2-6  3-1  Example of 9768 MRO orientation, right-side up ......................................................................................... 3-4  3-2  Pole-mount bracket attachment to a wide pole ............................................................................................... 3-5  3-3  Pole-mount bracket attachment to a small pole .............................................................................................. 3-5  3-4  Wall-mount bracket to pole-mount bracket ...................................................................................................... 3-6  3-5  Upper screws for attachment to wall-mount bracket..................................................................................... 3-9                                        3-6       Bracket ears of the wall-mount bracket ...........................................................................................................  3-99                              3-7  Lower screws for attachment to wall-mount bracket ................................................................................. ...3-10
List of procedures 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements    PRELIMINARY PRELIMINARY      3  Installing an 9768 MRO  3-1  Installing the 9768 MRO onto a wall or pole .................................................................................................. 3-3
About this document 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements    PRELIMINARY PRELIMINARY       Purpose  This document describes how to install the Alcatel-Lucent 9768 lightRadio™ Metro Radio Outdoor V1.0 B13 (9768 MRO) product.     Supported systems  This document assumes that a continuous stream of connected devices already delivers secure connectivity to the public network from one or more reachable places in the venue. With this assumption, the scope of the document is only the 9768 MRO and what is required to connect it to the network, meet its power needs, and ensure that it can be placed into reliable service.  Safety information  For your safety, this document contains safety statements. Safety statements are given at points where risks of damage to personnel, equipment, and operation may exist. Failure to follow the directions in a safety statement may result in serious consequences.
Safety 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 1-1   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY    1  Safety         Structure of safety statements   Overview   This topic describes the components of safety statements that appear in this document.   General structure  Safety statements include the following structural elements:   B  C  D  CAUTION Lifting hazard   E  F Lifting this equipment by yourself can result in injury due to the size and weight of the equipment.  G Always use three people or a lifting device to transport and position this equipment.  [ABC123]  H    Item Structure element Purpose 1 Safety alert symbol Indicates the potential for personal injury (optional) 2 Safety symbol Indicates hazard type (optional) 3 Signal word Indicates the severity of the hazard 4 Hazard type Describes the source of the risk of damage or injury 5 Safety message Consequences if protective measures fail 6 Avoidance message Protective measures to take to avoid the hazard
1-2 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   Safety Structure of safety statements   Item Structure element Purpose 7 Identifier The reference ID of the safety statement (optional)    Signal words   The signal words identify the hazard severity levels as follows:  Signal word Meaning DANGER Indicates an extremely hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Indicates a hazardous situation not related to personal injury.   General safety considerations   Shock hazards    WARNING  Electric-shock hazard  Some parts of all electrical installations are energized. Failure to follow safe work practices and the safety warnings may lead to bodily injury and property damage.  For this reason, only trained and qualified personnel (electrical workers as defined in IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No. 10) may install or service the installation.   WARNING  Electric-shock hazard There is a danger of electric shock if the grounding system is inadequate. You must comply with the grounding requirements for the grounding system.
    PRELIMINARY PRELIMINARY Safety Specific safety hazards  .................................................................................................................................................................................................................................... Specific safety hazards   Human irradiation by RF transmissions  The Federal Communications Commission (FCC) establishes and from time to time revises guidelines for human exposure to RF electromagnetic fields in the USA. Its Office of Engineering and Technology then publishes these guidelines in bulletins to allow companies, such as Alcatel-Lucent, who develop products that transmit non-ionizing RF waves to calculate safe human exposure distances, based on a corresponding amount of time spent within those distances.   Safe separation distance  The product complies with RF exposure limits of FCC Part 1.1310 Table 1 (B) Limits for General Population/Uncontrolled Exposure   The equipment must be installed and operated with a minimum separation distance as stated in the following power levels and operational modes.  Table 1-1 RF safe distance for different power levels  Power input to antenna RF safe distance from antenna for SISO mode RF safe distance from cabinet RADOM for SISO mode RF safe distance from antenna for 2x2 MIMO mode RF safe distance from cabinet RADOM for 2x2 MIMO mode 1000 mW 8.8” (22.34 cm) 8.3” (21 cm) 12.4” (31.6 cm) 11.9” (30.3 cm) 500 mW 6.2” (15.8 cm) 5.7” (14.5 cm) 8.8” (22.34 cm) 8.3” (21 cm)   At greater distances from the 9768 MRO, any duration of exposure is considered safe.
................................................................................................................................................................................................................................... 2-1 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY  2  Metro Radio Outdoor features         Functional features   Air interface and carrier band  The 9768 MRO is a dual transmit/dual receive path radio supporting frequency division duplex (FDD) LTE air interface. The 9768 MRO is ideally suited to support dense metro hot spots, with multiple-input multiple-output (MIMO) 2x2 operation in up to 10 MHz of bandwidth.  Note: 9768 MRO also supports a single Tx antenna (SIMO).    Antenna characteristics  The 9768 MRO comprises an integrated dual polarized Tx/Rx panel antenna.  • Frequency of operation 746 MHz - 787 MHz
.................................................................................................................................................................................................................................... 2-2 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA    September 2012 Metro Radio Outdoor features Power ....................................................................................................................................................................................................................................   PRELIMINARY PRELIMINARY  Power   Power system   The 9768 MRO requires a single phase, three-wire power source to provide nominal 120-V AC/ 208-V AC (measured at the input), line to neutral.   The following table summarizes the color codes:  Table 2-1  AC power system wiring color codes  Color Function Black Line White Neutral Green Ground / Protective earth (PE)    Power factor   The minimum power factor (ratio of working power to apparent power) is 0.92. Although this  value  is  above  the  typical  power  factor penalty threshold, it is unlikely to have a true impact on rates for power consumption.  AC frequency from source  The power supply of the 9768 MRO demands frequency of 47 Hz to 63 Hz from the voltage source, at any allowable level of voltage.
Metro Radio Outdoor features Physical properties ................................................................................................................................................................................................................................... 2-3 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY  ....................................................................................................................................................................................................................................   Physical properties   Form factor   The form factor of the 9768 MRO is as shown in Figure 2-1, “Form factor” (p. 2-3).  Figure 2-1  Form factor     Dimensions  The approximate dimensions of the 9768 MRO without its mounting hardware are as follows: • 17.9 inches (454 mm) high • 6.8 inches (173 mm) wide • 7.9 inches (200 mm) deep • 13 inches (332 mm) deep with its wall-mount bracket  Drill hole pattern   Following is an image providing a front view and side view of the drill hole pattern:  Figure 2-3  Front view and side view of the drill hole pattern
Metro Radio Outdoor features Power .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... 2-4 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA Issue 0.05   September 2012       Measurements are in mm [inches].
.................................................................................................................................................................................................................................... 2-3 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements Installing an 9768 MRO Procedure 3-1: Installing the 9768 MRO onto a wall or pole ....................................................................................................................................................................................................................................          3  Installing an 9768 MRO       Table 3-1 List of major components and subassemblies   CC Description 109791186 9768 MRO B13 (700U) 849172283 Antenna, KS24844 849168794 Filter, KS24799 L5   201376472   Amplifier, BNJ888, CDY-B13 P1.1   201376480   Radio, BNJ887, NG3e-B13 P1.1  1AF24959AAAA     Power Supply Unit, LCC250-12U-4P-401 (w/ Class A conducted emissions chokes)  1AF26285AAAA    Power Supply Unit, LCC250-12U-4P-402 (w/ Class B conducted emissions chokes)
.................................................................................................................................................................................................................................... 2-4 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA Issue 0.05   September 2012 Installing an 9768 MRO Procedure 3-1: Installing the 9768 MRO onto a wall or pole ....................................................................................................................................................................................................................................   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY     Procedure 3-1: Installing the 9768 MRO onto a wall or pole     Overview  This procedure includes guidelines for fastening the bracket, making the data connection, making the power connection, and rough-tuning the aim. It does not extend to bringing the 9768 MRO into operation, reading the status of the connected 9768 MRO, and optimizing its RF communications.   The 9768 MRO is designed to be installed with the right-side up orientation, as shown in the following image:  Figure 3-1  Example of 9768 MRO orientation, right-side up        Installing the 9768 MRO  Perform the following steps:  ...................................................................................................................................................................................................  1  If this is a pole-mount installation, attach the standard RRH pole-mount hardware to the pole.
.................................................................................................................................................................................................................................... 2-5 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements Installing an 9768 MRO Procedure 3-1: Installing the 9768 MRO onto a wall or pole ....................................................................................................................................................................................................................................   PRELIMINARY PRELIMINARY  The following image shows a pole with a wider diameter (152 mm - 380 mm).  Figure 3-2  Pole-mount bracket attachment to a wide pole     The following image shows a pole with a low diameter (50 mm - 152 mm). A separate pole-mount kit is available for poles measuring between 50 mm - 152 mm.  Figure 3-3  Pole-mount bracket attachment to a small pole
.................................................................................................................................................................................................................................... 2-6 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA Issue 0.05   September 2012 Installing an 9768 MRO Procedure 3-1: Installing the 9768 MRO onto a wall or pole ....................................................................................................................................................................................................................................   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY ...................................................................................................................................................................................................  2  Attach the wall-mount bracket • to the pole-mount bracket, if this is a pole-mount installation, using M10 hardware provided with the pole mount kit. • to the venue wall or façade, if this is a wall-mount installation, using M10 or 3/8 hardware.  Figure 3-4  Wall-mount bracket to pole-mount bracket        Figure 3-5  Upper screws for attachment to wall-mount bracket     ...................................................................................................................................................................................................  3  Push the 9768 MRO into the wall-mount bracket so that the top ears of the bracket slide
.................................................................................................................................................................................................................................... 2-7 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements Installing an 9768 MRO Procedure 3-1: Installing the 9768 MRO onto a wall or pole ....................................................................................................................................................................................................................................   into the slots that run along the sides of the back of the 9768 MRO.  ...................................................................................................................................................................................................  4  Slide the 9768 MRO downward until the tops of the slots in the mounting bracket ears meet the screws that you threaded into the side flanges of the 9768 MRO.
.................................................................................................................................................................................................................................... 2-8 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA Issue 0.05   September 2012 Installing an 9768 MRO Procedure 3-1: Installing the 9768 MRO onto a wall or pole ....................................................................................................................................................................................................................................   PRELIMINARY PRELIMINARY  Figure 3-6  Bracket ears of the wall-mount bracket     ...................................................................................................................................................................................................  5  Thread an M6x20 TR30 screw through each of the lower side flange holes  ...................................................................................................................................................................................................  6  Tighten all four mounting screws.
.................................................................................................................................................................................................................................... 2-1 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements ....................................................................................................................................................................................................................................   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY  Figure 3-7 Lower screws for attachment to wall-mount bracket        E...N...D.....O...F......S..T...E..P...S.....................................................................................................................................................................
................................................................................................................................................................................................................................... Q. Issue 0.05    September  2012   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY      Powering up the device  Perform the following steps:  ...................................................................................................................................................................................................  1  Test the power from the outlet of the junction box.  ...................................................................................................................................................................................................  2  If power to the junction box has been shut off, turn it on.  ...................................................................................................................................................................................................  3  Attach the customer-supplied waterproof plug (suitable for the supply voltage, 120-V AC, 208-V AC or 240-V AC) to the far end.  ................................................................................................................................................................................................... 4      Plug the power cord into the junction box outlet.  ...................................................................................................................................................................................................  5  Begin observing and noting the changes that occur in the LED indications of the 9768 MRO.  ...................................................................................................................................................................................................  6  When a steady-lit green indication has been achieved, inform the commissioning and integration team that the replacement has been successfully completed.  E...N...D.....O...F......S..T...E..P...S.....................................................................................................................................................................
A-1 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA Issue 0.05   September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY   Appendix A:  Product conformance statements     RoHS compliance   Statement of compliance  This product complies with EU RoHS Directive “6 of 6”, including the China version (Ref E3).   General safety   Statement of compliance  This product complies with CAN/CSA-C22.2 No.60950-1-07/UL-60950-1, Second Edition, Information Technology Equipment – Safety, Part 1: General Requirements. This covers safety requirements in the USA.   Emissions  Intentional radiator, statement of compliance   This product meets FCC Part 1.1310, Part 2 and FCC Part 27 requirements.  This product complies with EEC Directive 89/336/EEC for radiated emissions, which references FCC Part 15 Subpart B.   Unintentional radiator, statement of compliance  This product complies with FCC Part 15 Subpart B, Class B radiated and power line conducted emissions limit.  This product complies with CISPR 22 for radiated emissions, Class B. This standard addresses unintentional radiators.
................................................................................................................................................................................................................................... Q. Issue 0.05    September  2012   PRELIMINARY PRELIMINARY PRELIMINARY PRELIMINARY  Product conformance statements  Radiated interference..   Radiated interference   Statement of compliance  In accordance with FCC rules 15. 19 this product is labeled as follows “This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference”.  This product complies with FCC Part 15 Subpart B, Class B radiated and power line conducted emissions limit.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.   AC power supply conformance   IEC standard, statement of compliance  The AC power supply of this product complies with IEC 60364-1.   Telcordia standard, statement of compliance  The AC power supply of this product complies with Telcordia GR-1089 Section 7.
Appendix B: Other statements 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements B-1  ...................................................................................................................................................................................................................................     Product safety   Safety conformance statement  The 9768 MRO is safety certified by [Placeholder].  This Certification is marked on the equipment main nameplate label. Should the local Authority Having Jurisdiction (AHJ) require prior or additional verification of this Certification, a Product Certificate of Compliance can be obtained from the specific Certification Body by the Business/Product Unit Applicant for the product or by contacting Technical Support Services at (630) 224 4762, prompt 2. Any modifications to this equipment are not permitted without review and official written authorization from the specific Certification Body. Unauthorized changes may violate the Product Safety Certification. Modifications or changes authorized by official CN/CNN are assumed to have received prior approval from this Lab.    Collection and recovery   Eco-environmental statement  Packaging collection and recovery requirements. Countries, states, localities, or other jurisdictions may require that systems be established for the return and/or collection of packaging waste from the consumer, or other end user, or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the return and/or collection of the packaging waste may be established. For more information regarding collection and recovery of packaging and packaging waste within specific jurisdictions, contact the Alcatel-Lucent Environment, Health and Safety organization or Alcatel-Lucent Hazardous Waste Center technical support at (888) 539-2783.
Glossary .................................................................................................................................................................................................................................... GL-1 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY ...................................................................................................................................................................................................................................  A  AHJ   The agency or authority having jurisdiction. Article 100 of the National Electrical Code (NEC) for the United States defines AHJ with greater specificity, stating that it may be a federal, state, local government, or individual such as a fire chief, fire marshal, chief of a fire prevention bureau, labor department or health department, building official or electrical inspector, or others having statutory authority. In some circumstances, the property owner or his/her agent assumes the roles, and at government installations, the commanding officer or departmental official may be the AHJ.  ...................................................................................................................................................................................................................................  B  BBU  Baseband unit, the digital signal processor that connects the MRO to the network and provides the timing and logic for periodic sync signals. In this context, the BBU is the master, and the MRO is the slave. Thus, the fiber optic cable from the BBU should be connected to the slave port of the MRO.  ...................................................................................................................................................................................................................................  C  CAN/CSA Canadian Standards Association. See http://www.csa.ca (http://www.csa.ca).  CE Mark The official logo that substantiates the manufacturer whose product bears it has complied with all EEC directives that apply. See also EEC directive.  CFR  Code of Federal Regulations. Among these regulations, Title 47, “Telecommunication,” conveys the rules of the FCC companies operating networks in the USA. See also FCC.  CPRI  Common Public Radio Interface. Alcatel-Lucent was one of several major companies who participated in defining the specification for this interface between the radio (the MRO in this case) and the radio equipment controller (the BBU in this case). See also BBU.  ...................................................................................................................................................................................................................................  D  d2U   The BBU system supporting two controller and two modems. See also BBU.
Glossary .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... GL-2 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements        9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012   PRELIMINARY PRELIMINARY E  EEC directive A law enacted by the European Union for enforcement by its Common Market. The terms of such a law have been used as a point of reference against which to compare the intentional RF emissions of the MRO.  EIRP  The equivalent isotropically radiated power. The density of the peak power of a radio in the direction of its greatest amount of gain. This is typically expressed in dBm, a measure relative to power out per mW.  ESD  Electrostatic discharge, a hazard that electronic equipment such as the MRO can suffer by way of exposure to static electricity or proximity to something that has no connection to ground.  ...................................................................................................................................................................................................................................  F  FCC  Federal Communications Commission. Its Wireless Communications Service (WCS) bureau regulates, among other services, commercial services in the upper 700-MHz frequency band in the USA.  FDD  Frequency-division duplexing, a radio indexing system whose transmit and receive signals are on differing carrier frequencies.  FRU  Field-replaceable unit, a designation connoting that the part can be removed in favor of a new one when diagnostic exercises seem to have isolated a fault to the part. The overall implication is that, if those exercises point to either no particular part, then the entire unit should be replaced. In the case of the MRO, the only FRUs are the SFP port modules (see also SFPs) and the whole MRO itself.  ...................................................................................................................................................................................................................................  G  GR   Generic requirements published by Telcordia Technologies. See also Core.  ...................................................................................................................................................................................................................................  I  IEC  International Electrotechnical Commission. The MRO complies with numerous standards that this independent body has propagated.  ...................................................................................................................................................................................................................................  L  LC   A small connector that terminates a fiber optic cable and snaps into its mate.
.................................................................................................................................................................................................................................... GL-3 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY Glossary  .................................................................................................................................................................................................................................... lR A member of the Alcatel-Lucent lightRadio™ family of wireless products. The MRO belongs to this family.  LTE   3GPP Long Term Evolution wireless standard for high-speed data devices. Evolution implies that the air interface has evolved from GSM/UMTS standards to an OFDM-based air interface that realizes peak rates of 300 Mbps downlink and 75 Mbps uplink at less than 5 ms latency. See also 3GPP and OFDM.  ...................................................................................................................................................................................................................................  O  OFDM  Orthogonal frequency-division multiplexing, the multi-carrier modulation scheme that overcomes many commonly experienced wireless communications problems, such as multipath and signal attenuation.  ...................................................................................................................................................................................................................................  P  PDCP  Packet Data Convergence Protocol, which provides security to both the air interface and the fiber optic interface of the MRO by compressing and decompressing the IP headers, as specified in the UMTS protocol stack.  ...................................................................................................................................................................................................................................  R  Radiall  The proprietary name of an enterprise that produces components for device interconnections. These components include the R2CT weatherized connector kit by which the MRO installer retrofits the LC fiber optic connector on the backhaul cable to the SFP port module of the MRO. The proper name of this company is Radiall USA, Inc. See also SFP.  RoHS  The Restriction of Hazardous Substances Directive, a law enacted by the European Union for enforcement by its Common Market in order to restrict six particular materials in electrical and electronic products. These materials are the elements lead, mercury, and cambium, and three compounds. More broadly, the standard QC 080000 propagates RoHS specifications throughout the world and thus impacts the choice of regions, nations, and states and provinces selected to regulate the same substances. The MRO is fully compliant with the RoHS directive.  RRH   Remote RF head consisting of a radio, a receive filter, a transmit amplifier, and a CPRI link to a BBU. The MRO is an RRH. See also BBU and CPRI.  ...................................................................................................................................................................................................................................  S  SFP   A small form-factor pluggable module, which serves as the connector in the MRO for the fiber
Glossary .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... GL-4 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012   optic interface to the BBU. This module is an FRU. See also BBU and FRU.
.................................................................................................................................................................................................................................... GL-5 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY SIMO  Single input, multiple output. Its transmitter function uses a one antenna, and its receiver function uses two. This scheme reduces the instance of multipath and fading, in particular. Antonyms are MISO (multiple input, single output) and MIMO (multiple input, multiple output).  ...................................................................................................................................................................................................................................  W  W-CDMA Wideband code division multiplex air interface, used by UMTS-FDD. See also FDD.
.................................................................................................................................................................................................................................... IN-1 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY Index              Numerics 6 of 6 (EU RoHS Directive), A-1  9926 BBU  interface to, 2-2 ................................................................................................  A  AC power supply, A-3  Amperage, 2-2  Ancillary equipment optional, 2-8 required, 2-8 Antenna characteristics, 2-1 Assumptions, xi  Audience for this document, xi  Authority having jurisdiction (AHJ)  definition of, GL-1  when demanding verification, B-1  AWG of power feed wire, 2-2  Azimuth, 2-4 ................................................................................................  B  Backhaul, 2-8  Band of operation, 2-1  Beam width, 2-1  Bracket  pole-mount, 2-8 wall-mount, 2-4 ................................................................................................  C  CAN/CSA-C22.2, A-1  Carrier band, 2-1  China version of RoHS Directive, A-1  CISPR 22, A-1  Collection and recovery, B-1  Conducted immunity, A-2  Conducted spurious emissions, A-1  Conformance statements, A-1  Conventions used in this document, xiii  CPRI interface, 2-2  CPRI Line Bit Rate, 2-8 ................................................................................................  D  Data interface, 2-8  Depth, 2-4  Dimensions, 2-4  Directive 89/336, A-1  Distance  human from 9768 MRO in operation, 1-3  Documents  conventions used, xiii ordering, xiii other related, xiii support for use of, xiii
.................................................................................................................................................................................................................................... IN-2 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements        9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Index   PRELIMINARY PRELIMINARY  .................................................................................................................................................................................................................................... ................................................................................................  E  Eco-environmental statement, B-1  EEC Directive 89/336, A-1  Elevation beam, 2-4 Emissions  intentionally radiated, A-1 unintentionally radiated, A-1 Environment and waste support contact information, B-1  ESD immunity, A-2  EU RoHS Directive, A-1 ................................................................................................  F  Fasteners all, 3-2 FCC guidelines for exposure to RF radiation, 1-3  FCC Part 15, A-1, A-2  Fiber optic cable, 2-8, 2-8  Form factor, 2-3  Frequency band, 2-1  Fronthaul interface, 2-8  FRU, 2-2  FullAXS connector, 2-8 ................................................................................................  G  Gain, 2-1  GR-1089, A-2, A-3  GR-1089-2628, A-1 ................................................................................................  H  Handoff to another technology, 2-1  Height, 2-4 ................................................................................................  I   IEC 50529, A-3  IEC 60364-1, A-3  IEC 61000-4-3, A-2 IEC 61000-4-6, A-2  Immunity to radiated interference, A-2, A-2  Information Technology Equipment – Safety, A-1  Installation procedure, 3-3  Intentionally radiated emissions, A-1  Interface air, 2-1 data, 2-1 Isotropic reference gain, 2-1 ................................................................................................  M  Mounting procedure, 3-3 ................................................................................................  O  Online customer support (OLCS), xiii  Ordering documents, xiii ................................................................................................  P  Parts for installation, 3-1  PDCP, 2-1  Pole-mount bracket kits, 2-8 Ports, spurious emissions, A-1  Power  consumption, 2-2 factor, 2-3 frequency, 2-3 transmitted, 2-1 Power supply, A-3  Product Safety Certification, B-1  Protection Code IP20, A-3  Protocol, 2-1 ................................................................................................  R  Radiated emissions, A-1, A-1  Radiated interference, A-2  Recovery, B-1
.................................................................................................................................................................................................................................... IN-3 9768 lR MRO V1.0 B13 3MN-01751-0002-RJZZA September 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements   PRELIMINARY PRELIMINARY Index  .................................................................................................................................................................................................................................... Recycling, B-1  Reference gain, 2-1  RoHS Directive, A-1 ................................................................................................  S  Safety  certification, B-1  general requirements, A-1  Security  through software, 2-1  Security cover, 2-8  SFP module, 2-2, 2-8  Solar shield, 2-7  Solids, ingress, A-3  Speed of data link, 2-8  Spurious emissions, A-1  Statements of compliance, A-1  Support  environment and waste issues, contact information, B-1  services, contact information, B-1 technical, xiii using documents, xiii  Synchronization, 2-2 ................................................................................................  T  Technical support per country, xiii services, contact information, B-1  Technology, 2-1  Temperature range, 2-7  Tilt adjustment range, 2-4  Timing, 2-2  Torx drivers required, 3-2 ................................................................................................  U  Unintentionally radiated emissions, A-1  Uninterruptible power, 2-2 ................................................................................................  V  Voltage, 2-2 ................................................................................................  W Wall-mount bracket  adjustability for azimuth and elevation, 2-4 depth, 2-4 screws, 2-4 weight, 2-4 Waste, B-1  Wattage, 2-2  Weight, 2-4  Width, 2-4

Navigation menu