Nokia of America ONEBTS-23 AWS DIGITAL HOST WIRELESS BASE STATION User Manual USERS MANUAL 3
Alcatel-Lucent USA Inc. AWS DIGITAL HOST WIRELESS BASE STATION USERS MANUAL 3
Contents
- 1. USERS MANUAL 1
- 2. USERS MANUAL 2
- 3. USERS MANUAL 3
- 4. USERS MANUAL 4
USERS MANUAL 3
Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet CONNECT T1-3 (J3) CABLE HERE CONNECT T1-2 (J2) CABLE HERE CONNECT T1-1 (J1) CABLE HERE CONNECT T1-6 (USER RELAY) CABLE HERE CONNECT T1-5 (SECB2) CABLE HERE CONNECT T1-4 (SECB1) CABLE HERE FRONT The figure below shows the hatchplate with new labels (if available) on the BTS 8420Digital Only version with two Digital Shelves. CONNECT T1-3 (BOT SHELF J3) CABLE HERE BOT SHELF (J3) BOT SHELF (J2) CONNECT T1-2 (BOT SHELF J2) CABLE HERE BOT SHELF (J1) CONNECT T1-6 (TOP SHELF J3) CABLE HERE TOP SHELF (J2) TOP SHELF (J1) TOP SHELF (J3) CONNECT T1-5 (TOP SHELF J2) CABLE HERE CONNECT T1-1 (BOT SHELF J1) CABLE HERE CONNECT T1-4 (TOP SHELF J1) CABLE HERE FRONT .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-18 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Important! Skip step 2 if the BTS 8420 radio cabinet does not have integrated power and go to Step 3. ................................................................................................................................................................................................... For BTS 8420 radio cabinets with integrated power, locate the T1/E1 cables shipped with the cabinet. For the AWS 8420 and all versions of the BTS 8420 radio cabinet except the Digital Only version with two Digital Shelves, ensure both ends of the T1 cables are labeled “T1-1,” “T1-2,”and “T1-3” (as applicable) and connect them to the Integrated Power Module on top of the BTS 8420/AWS 8420 radio cabinet. For the BTS 8420 Digital Only version with two Digital Shelves, ensure that the T1 cables are labeled as follows: “T1-1 for Digital Shelf 1,” “T1-2 for Digital Shelf 1,” “T1-3 for Digital Shelf 1,” “T1-4 for Digital Shelf 2,” “T1-5 for Digital Shelf 2,” and “T1-6 for Digital Shelf 2,” as applicable. Connect the T1 cables to the Universal Hatchplate on the BTS 8420 radio cabinet according to one of the figures below. Refer to the figure immediately below if the Integrated Power Module bracket has labels specifically designed for BTS 8420 Digital Only version with two Digital Shelves. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-19 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet TOP SHELF (J2) TOP SHELF (J1) How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet CONNECT T1-5 CABLE HERE CONNECT T1-6 CABLE HERE CONNECT T1-3 CABLE HERE CONNECT T1-4 CABLE HERE USER ALARMS 16-31 USER ALARMS 0-15 TOP SHELF (J3) BOT SHELF (J3) 485 RET CONNECT T1-2 CABLE HERE BOT SHELF (J2) CONNECT T1-1 CABLE HERE BOT SHELF (J1) Refer to the figure below if Integrated Power Module bracket has the original labels. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-20 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... Route the T1/E1 cable(s) to the location of the Z-IDC punchdown block (or equivalent), if the NIU is located more than the 10 meter (33 foot) cable length from the BTS 8420/AWS 8420 radio cabinet. Otherwise, route the T1/E1 cable(s) directly to the NIU. Refer to the appropriate figure below. Important! When performing the next step, secure the cable to the ladder rack using standard procedures, including the use of cable ties. ................................................................................................................................................................................................... Tie the T1/E1 cable(s) to the ladder rack. Refer to the appropriate figure below. The following figure applies to both BTS 8420 and AWS 8420 radio cabinets with integrated power. PUNCHDOWN BLOCK OR EQUIVALENT T1/E1 CABLES TIE CABLE TO LADDER RACK HORIZONTAL LADDER RACK TO BRACKET ON INTEGRATED POWER MODULE INTEGRATED POWER MODULE BTS 8420 RADIO CABINET The following figure applies to both BTS 8420 and AWS 8420 radio cabinets without integrated power. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-21 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet PUNCHDOWN BLOCK OR EQUIVALENT T1/E1 CABLES TIE CABLE TO LADDER RACK HORIZONTAL LADDER RACK TO UNIVERSAL HATCHPLATE BTS 8420 RADIO CABINET E................................................................................................................................................................................................... ND OF STEPS .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-22 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Connect twisted-wire pairs in T1/E1 cables to appropriate Z-IDC punchdown blocks (or equivalent) -- for AWS 8420 and all versions of BTS 8420 except Digital Only version with two Digital Shelves. Important! Z-IDC punchdown blocks are used only if the distance from the NIU to the BTS 8420/AWS 8420 is greater than the 10 meter (33 foot) cable length. Otherwise, T1/E1 connections are made directly to the NIU. Each T1/E1 cable contains eight twisted-wire pairs. One end is terminated with a 25-pin, D-sub connector. The 25-pin, D-sub connector is connected to the BTS 8420/AWS 8420 radio cabinet. The end with loose wires is punched down at the Z-IDC punchdown blocks (i.e., punchdown block 1-5 on the NIU) or equivalent. When URCs are used in the Digital Shelf: T1-1 is connected to punchdown block 1 on the NIU, T1-2 is connected to punchdown block 2 on the NIU, and T1-3 is connected to punchdown block 3 on the NIU. Each T1/E1 cable supports up to four T1/E1 Voice lines or one Data line, as follows: • • • First cable (T1-1): One to four T1/E1 lines (one Data line or one to four Voice lines, mutually exclusive) to punchdown block 1 on the NIU -- applies to URCs or URC-IIs Second cable (T1-2): One to four T1/E1 lines (Voice only) to punchdown block 2 on the NIU -- applies to URCs or URC-IIs Third cable (T1-3): One to four T1/E1 lines (Voice only) to punchdown block 3 on the NIU -- applies to URCs or URC-IIs Connect the T1/E1 twisted-wire pairs to the punchdown terminals on the EQUIPMENT SIDE of the appropriate Z-IDC punchdown block (or equivalent) according to the following procedure. See Step 10 for the Z-IDC punchdown block wiring tables. ................................................................................................................................................................................................... Important! When performing the following procedure, note that line numbers have already been assigned to signal pairs by the customer during site preparation (i.e., when the lines were punched down at the NETWORK SIDE of each Z-IDC punchdown block). Locate the cable marked T1-1 and Z-IDC punchdown block 1. For the location of the punchdown blocks on the NIU, for all versions of the BTS 8420 radio cabinet except the Digital Only version with two Digital Shelves, refer to“Layout of Z-IDC punchdown blocks” (p. 5-13) ................................................................................................................................................................................................... Route the cable through the cable strain relief clip at the top of the Z-IDC punchdown block. Refer to the figure below. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-23 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... Remove sufficient cable insulation and drain shield to expose enough wire to reach the punchdown connections on the punchdown block. Refer to the figure below. THREAD THE CABLE, IN THE DIRECTION SHOWN, THROUGH THE STRAIN RELIEF CLIP AT THE TOP OF THE BLOCK WIRE TIE THE CABLE TO THE STRAIN RELIEF CLIP AS SHOWN GROUNDING LUG AND #6 AWG PIGTAIL FROM HALO GROUND (Part of site preparation) 10 10 LEFT SIDE VIEW FRONT VIEW INSULATION, SHIELD, AND DRAIN WIRE REMOVED The connectorized end of Indoor T1/E1 and user alarm cable shields are bonded to the radio cabinet hatch plate via the D-sub connector. ................................................................................................................................................................................................... Route the cable wires down the side of the punchdown block closest to the side to where the punchdown connections will be made. See the figure below. ................................................................................................................................................................................................... Fan out the wires to the punchdown connections. (Be sure to leave plenty of slack.) .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-24 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... WARNING Equipment Damage Z-IDC punchdown tool (ITE No. R-6097) must be used when performing this step. Any other tool will damage the Z-IDC punchdown block. Orient the Z-IDC punchdown tool (ITE No. R-6097) so the cutter faces the middle of the Z-IDC punchdown block. Refer to the following figure. ................................................................................................................................................................................................... Punch down twisted-wire pairs 1-8 at punchdown block 1, according to the appropriate table below. Cut off any excess wire. ................................................................................................................................................................................................... Locate the cable labeled T1-2 (if applicable) and punchdown block 2. Repeat Steps 2 through 6. Punch down twisted-wire pairs 1-8 at punchdown block 2, according to the appropriate table below. Cut off any excess wire. ................................................................................................................................................................................................... Locate the cable marked T1-3 (if applicable) and punchdown block 3. Repeat Steps 2 through 6. Punch down twisted-wire pairs 1-8 at punchdown block 3, according to the appropriate table below. Cut off any excess wire. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-25 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... 10 Connect the T1/E1 cables according to the following table. The following tables provide the T1/E1 cable, twisted-wire pair connections for cables T1-1, T1-2, and T1-3. These cables go to the EQUIPMENT SIDE of the Z-IDC punchdown blocks. URC or URC-II, Position 1, Data or Voice, mutually exclusive Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block, if applicable. (See Note 1) LINE T1-1 cable wire color Pair code. To be punched down at customer provided punchdown block at NIU. (See Note 4) White-Blue Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White LINE White-Slate Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx, Tip/Ring Equipment side of Z-IDC punchdown block 1, if applicable. (See Note 2) URC or URC-II, Position 1. 25 pin, D-sub pin # Tx T 1-1 Upper Tx R 1-1 Lower Rx T 1-2 Upper 16 Rx R 1-2 Lower 15 Tx T 1-3 Upper Tx R 1-3 Lower Rx T 1-4 Upper 19 Rx R 1-4 Lower 18 Tx T 1-5 Upper Tx R 1-5 Lower Rx T 1-6 Upper 22 Rx R 1-6 Lower 21 Tx T 1-7 Upper 11 Tx R 1-7 Lower 10 Rx T 1-8 Upper 25 Rx R 1-8 Lower 24 Notes: 1. Data or Voice T1/E1 lines must be assigned to Z-IDC Punchdown Block 1 (URC or URC-II). Data and Voice are mutually exclusive. 2. EXAMPLE 1-3 Lower = Block Number 1, Position 3, Lower 3. The Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables at the customer’s NIU must not be looped back towards the BTS 8420/AWS 8420 while the radio is in operation. 4. Use the T1-1 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-26 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet URC or URC-II, Position 2, Voice only Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block, if applicable. (See Note 1.) LINE T1-2 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White LINE White-Slate Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 2, if applicable.(See Note 2.) URC or URC-II, Position 2. 25 pin, D-sub pin # Tx T 2-1 Upper Tx R 2-1 Lower Rx T 2-2 Upper 16 Rx R 2-2 Lower 15 Tx T 2-3 Upper Tx R 2-3 Lower Rx T 2-4 Upper 19 Rx R 2-4 Lower 18 Tx T 2-5 Upper Tx R 2-5 Lower Rx T 2-6 Upper 22 Rx R 2-6 Lower 21 Tx T 2-7 Upper 11 Tx R 2-7 Lower 10 Rx T 2-8 Upper 25 Rx R 2-8 Lower 24 Notes: 1. Only Voice T1/E1 lines may be assigned to Z-IDC Punchdown Block #2 (URC or URC-II, Position 2). 2. EXAMPLE 2-3 Lower = Punchdown Block #2, Position 3, Lower 3. Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables, at the customer’s NIU, must not be looped back towards the BTS 8420/AWS 8420 while the radio is in operation. 4. Use the T1-2 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-27 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet URC or URC-II, Position 3, Voice only Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block, if applicable. (See Note 1.) LINE T1-3 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White LINE White-Slate Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 3, if applicable. (See Note 2.) URC or URC-II, Position 3. 25 pin, D-sub pin # Tx T 3-1 Upper Tx R 3-1 Lower Rx T 3-2 Upper 16 Rx R 3-2 Lower 15 Tx T 3-3 Upper Tx R 3-3 Lower Rx T 3-4 Upper 19 Rx R 3-4 Lower 18 Tx T 3-5 Upper Tx R 3-5 Lower Rx T 3-6 Upper 22 Rx R 3-6 Lower 21 Tx T 3-7 Upper 11 Tx R 3-7 Lower 10 Rx T 3-8 Upper 25 Rx R 3-8 Lower 24 Notes: 1. Only Voice T1/E1 lines may be assigned to Punchdown Block 3 (URC or URC-II, Position 3). 2. EXAMPLE 3-3 Lower = Block Number 3, Position 3, Lower 3. Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables, at the customer’s NIU, must not be looped back towards the BTS 8420/AWS 8420 while the radio is in operation. 4. Use the T1-3 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. E................................................................................................................................................................................................... ND OF STEPS .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-28 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Connect twisted-wire pairs in T1/E1 cables to appropriate Z-IDC punchdown blocks (or equivalent) -- for BTS 8420 Digital Only version with two Digital Shelves. Important! Each T1/E1 cable contains eight twisted-wire pairs. One end is terminated with a 25-pin D-sub connector. The 25-pin, D-sub connector is connected to the BTS 8420 radio cabinet. The end with loose wires is punched down at the appropriate Z-IDC punchdown block (if applicable) or the punchdown block provided by the customer at the NIU. Z-IDC punchdown blocks are used only if the NIU is located more than the 10 meter (33 foot) cable length from the BTS 8420. Otherwise, T1/E1 connections are made directly to the NIU. If Z-IDC punchdown blocks are to be used, proceed with the steps which follow. When URCs or URC-IIs are used in the first Digital Shelf: T1-1 is connected to punchdown block 1 on the NIU, T1-2 is connected to punchdown block 2 on the NIU, and T1-3 is connected to punchdown block 3 on the NIU. When URCs or URC-IIs are used in the second Digital Shelf: T1-4 is connected to punchdown block 4 on the NIU, T1-5 is connected to punchdown block 5 on the NIU, and T1-6 is connected to punchdown block 6 on the NIU. Each T1/E1 cable supports up to four T1/E1 Voice or Data lines, as follows: • • • • • • First cable (T1-1): Data or Voice (one to four T1/E1 lines) (mutually exclusive) to punchdown block 1 on NIU -- applies to URCs or URC-IIs Second cable (T1-2): One to four T1/E1 lines (Voice only) to punchdown block 2 on NIU-- applies to URCs or URC-IIs Third cable (T1-3): One to four T1/E1 lines (Voice only) to punchdown block 3 on NIU -- applies to URCs or URC-IIs Forth cable (T1-4): Data or Voice (one to four T1/E1 lines) (Mutually exclusive) to punchdown block 4 on NIU -- applies to URCs or URC-IIs Fifth cable (T1-5): One to four T1/E1 lines (Voice only) to punchdown block 5 on NIU -- applies to URCs or URC-IIs Sixth cable (T1-6): One to four T1/E1 lines (Voice only) to punchdown block 6 on NIU -- applies to URCs or URC-IIs Connect the twisted-wire pairs in the T1/E1 cables to the punchdown terminals on the EQUIPMENT SIDE of the appropriate Z-IDC punchdown block (or equivalent) according to the following procedure. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-29 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... Important! When performing the following procedure, note that line numbers have already been assigned to signal pairs by the customer during site preparation (i.e., when the lines were punched down at the NETWORK SIDE of the Z-IDC punchdown blocks). Locate the cable labeled “T1-1 for Digital Shelf 1” (T1-1) and Z-IDC punchdown block 1. Refer to the figure on page 5-13 for the location of the punchdown blocks on the NIU, for the Digital Only version with two Digital Shelves.“Layout of Z-IDC punchdown blocks” (p. 5-14) ................................................................................................................................................................................................... Route the cable through the cable strain relief clip at the top of the Z-IDC punchdown block. Refer to the figure in the next step. ................................................................................................................................................................................................... Remove sufficient cable insulation and drain shield to expose enough wire to reach the punchdown connections on the punchdown block. Refer to the figure below. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-30 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet THREAD THE CABLE, IN THE DIRECTION SHOWN, THROUGH THE STRAIN RELIEF CLIP AT THE TOP OF THE BLOCK WIRE TIE THE CABLE TO THE STRAIN RELIEF CLIP AS SHOWN GROUNDING LUG AND #6 AWG PIGTAIL FROM HALO GROUND (Part of site preparation) 10 10 LEFT SIDE VIEW FRONT VIEW INSULATION, SHIELD, AND DRAIN WIRE REMOVED The connectorized end of Indoor T1/E1 and user alarm cable shields are bonded to the radio cabinet hatch plate via the D-sub connector. ................................................................................................................................................................................................... Route the cable wires down the side of the punchdown block, closest to the punchdown terminals, where the punchdown connections will be made. See the figure below. ................................................................................................................................................................................................... Fan out the wires to the punchdown connections. (Be sure to provide plenty of slack.) .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-31 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... WARNING Equipment Damage Be sure to use Z-IDC punchdown tool (ITE No. R-6097) when performing this step. Any other tool will damage the Z-IDC punchdown block. Position the Z-IDC punchdown tool (ITE No. R-6097) so that the cutter faces the middle of the Z-IDC punchdown block. Refer to the following figure. ................................................................................................................................................................................................... Punch down twisted-wire pairs 1-8 at punchdown block 1, according to the appropriate table below. Cut off any excess wire. ................................................................................................................................................................................................... Locate the cable labeled “T1-2 for Digital Shelf 1” (T1-2) and punchdown block 2. Repeat Steps 2-6. Punch down twisted-wire pairs 1-8 at punchdown block 2, according to the appropriate table below. Cut off any excess wire. ................................................................................................................................................................................................... Locate the cable labeled “T1-3 for Digital Shelf 1” (T1-3) and punchdown block 3. Repeat Steps 2-6. Punch down twisted-wire pairs 1-8 at punchdown block 3, according to the appropriate table below. Cut off any excess wire. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-32 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... 10 Locate the cable labeled “T1-4 for Digital Shelf 2” (T1-4) and punchdown block 4. Repeat Steps 2-6. Punch down twisted-wire pairs 1-8 at punchdown block 4, according to the appropriate table below. Cut off any excess wire. ................................................................................................................................................................................................... 11 Locate the cable labeled “T1-5 for Digital Shelf 2” (T1-5) and punchdown block 5. Repeat Steps 2-6. Punch down twisted-wire pairs 1-8 at punchdown block 5, according to the appropriate table below. Cut off any excess wire. ................................................................................................................................................................................................... 12 Locate the cable labeled “T1-6 for Digital Shelf 2” (T1-6) and punchdown block 6. Repeat Steps 2-6. Punch down twisted-wire pairs 1-8 at punchdown block 6, according to the appropriate table below. Cut off any excess wire. ................................................................................................................................................................................................... 13 Connect the T1/E1 cables according to the following tables. The following tables list the twisted-wire pair connections for cables “T1-1 for Digital Shelf 1,” “T1-2 for Digital Shelf 1,” “T1-3 for Digital Shelf 1,” “T1-1 for Digital Shelf 2,” “T1-2 for Digital Shelf 2,” and “T1-3 for Digital Shelf 2.” These cables (24 T1/E1 lines) are connected to the EQUIPMENT SIDE of each corresponding Z-IDC punchdown block. Tx/Rx signal twisted wire-pair connections are shown for Positions 1,2,3 on the first Digital Shelf and Positions 1,2,3 on the second Digital Shelf. Data or Voice, mutually exclusive, Digital Shelf 1 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block by customer, if applicable. (See Note 1.) LINE T1-1 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White Function Tx/Rx, Tip/Ring Equipmnt side of Z-IDC punchdown block 1, if applicable. (See Note 2.) URC or URC-II, Position 1. 25 pin, D-sub pin # Tx T 1-1 Upper Tx R 1-1 Lower Rx T 1-2 Upper 16 Rx R 1-2 Lower 15 Tx T 1-3 Upper Tx R 1-3 Lower Rx T 1-4 Upper 19 Rx R 1-4 Lower 18 .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-33 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Data or Voice, mutually exclusive, Digital Shelf 1 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block by customer, if applicable. (See Note 1.) LINE T1-1 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Slate Pair Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx, Tip/Ring Equipmnt side of Z-IDC punchdown block 1, if applicable. (See Note 2.) URC or URC-II, Position 1. 25 pin, D-sub pin # Tx T 1-5 Upper Tx R 1-5 Lower Rx T 1-6 Upper 22 Rx R 1-6 Lower 21 Tx T 1-7 Upper 11 Tx R 1-7 Lower 10 Rx T 1-8 Upper 25 Rx R 1-8 Lower 24 Notes: 1. Data or Voice T1/E1 lines must be assigned to Z-IDC Punchdown Block 1 (URC or URC-II). Data and Voice are mutually exclusive. 2. EXAMPLE 1-3 Lower = Block Number 1, Position 3, Lower 3. The Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables at the customer’s NIU must not be looped back towards the BTS 8420 while the radio is in operation. 4. Use the T1-1 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. Voice only, Digital Shelf 1 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block by customer, if applicable. (See Note 1.) LINE T1-2 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 2, if applicable. (See Note 2.) URC or URC-II, Position 2. 25 pin, D-sub pin # Tx T 2-1 Upper Tx R 2-1 Lower Rx T 2-2 Upper 16 Rx R 2-2 Lower 15 Tx T 2-3 Upper Tx R 2-3 Lower Rx T 2-4 Upper 19 Rx R 2-4 Lower 18 .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-34 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Voice only, Digital Shelf 1 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block by customer, if applicable. (See Note 1.) LINE T1-2 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) Pair White-Slate Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 2, if applicable. (See Note 2.) URC or URC-II, Position 2. 25 pin, D-sub pin # Tx T 2-5 Upper Tx R 2-5 Lower Rx T 2-6 Upper 22 Rx R 2-6 Lower 21 Tx T 2-7 Upper 11 Tx R 2-7 Lower 10 Rx T 2-8 Upper 25 Rx R 2-8 Lower 24 Notes: 1. Only Voice T1/E1 lines may be assigned to Z-IDC Punchdown Block #2 (URC or URC-II, Position 2). 2. EXAMPLE 2-3 Lower = Punchdown Block #2, Position 3, Lower 3. Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables, at the customer’s NIU, must not be looped back towards the BTS 8420 while the radio is in operation. 4. Use the T1-1 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. Voice only, Digital Shelf 1 Customer assigned T1/E1 Line Number. (Cable to be punched down at Equipment side of Z-IDC block by customer.) See Note 1. LINE T1-3 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 3, if applicable. (See Note 2.) URC or URC-II, Position 3. 25 pin, D-sub pin # Tx T 3-1 Upper Tx R 3-1 Lower Rx T 3-2 Upper 16 Rx R 3-2 Lower 15 Tx T 3-3 Upper Tx R 3-3 Lower Rx T 3-4 Upper 19 Rx R 3-4 Lower 18 .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-35 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Voice only, Digital Shelf 1 Customer assigned T1/E1 Line Number. (Cable to be punched down at Equipment side of Z-IDC block by customer.) See Note 1. LINE T1-3 cable wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Slate Pair Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 3, if applicable. (See Note 2.) URC or URC-II, Position 3. 25 pin, D-sub pin # Tx T 3-5 Upper Tx R 3-5 Lower Rx T 3-6 Upper 22 Rx R 3-6 Lower 21 Tx T 3-7 Upper 11 Tx R 3-7 Lower 10 Rx T 3-8 Upper 25 Rx R 3-8 Lower 24 Notes: 1. Only Voice T1/E1 lines may be assigned to Punchdown Block 3 (URC or URC-II, Position 3). 2. EXAMPLE 3-3 Lower = Block Number 3, Position 3, Lower 3. Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables, at the customer’s NIU, must not be looped back towards the BTS 8420 while the radio is in operation. 4. Use the T1-3 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. Data or Voice, mutually exclusive, Digital Shelf 2 Customer assigned T1/E1 Line Number. (Cable to be punched down at Equipment side of Z-IDC block by customer.) See Note 1. LINE T1-4 (SECB-1) wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White Function Tx/Rx, Tip/Ring Equipment side of Z-IDC punchdown block 4, if applicable. (See Note 2.) URC or URC-II, Position 1. 25 pin, D-sub pin # Tx T 4-1 Upper Tx R 4-1 Lower Rx T 4-2 Upper 16 Rx R 4-2 Lower 15 Tx T 4-3 Upper Tx R 4-3 Lower Rx T 4-4 Upper 19 Rx R 4-4 Lower 18 .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-36 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Data or Voice, mutually exclusive, Digital Shelf 2 Customer assigned T1/E1 Line Number. (Cable to be punched down at Equipment side of Z-IDC block by customer.) See Note 1. LINE T1-4 (SECB-1) wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Slate Pair Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx, Tip/Ring Equipment side of Z-IDC punchdown block 4, if applicable. (See Note 2.) URC or URC-II, Position 1. 25 pin, D-sub pin # Tx T 4-5 Upper Tx R 4-5 Lower Rx T 4-6 Upper 22 Rx R 4-6 Lower 21 Tx T 4-7 Upper 11 Tx R 4-7 Lower 10 Rx T 4-8 Upper 25 Rx R 4-8 Lower 24 Notes: 1. Data or Voice T1/E1 lines must be assigned to Z-IDC Punchdown Block 4 (URC or URC-II). Data and Voice are mutually exclusive. 2. EXAMPLE 4-3 Lower = Block Number 1, Position 3, Lower 3. The Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables at the customer’s NIU must not be looped back towards the BTS 8420 while the radio is in operation. 4. Use the T1-4 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. Voice only, Digital Shelf 2 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block, if applicable. (See Note 1.) LINE T1-5 (SECB-2) wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 5, if applicable. (See Note 2.) Goes to URC or URC-II, Position 2. 25 pin, D-sub pin # Tx T 5-1 Upper Tx R 5-1 Lower Rx T 5-2 Upper 16 Rx R 5-2 Lower 15 Tx T 5-3 Upper Tx R 5-3 Lower Rx T 5-4 Upper 19 Rx R 5-4 Lower 18 .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-37 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Voice only, Digital Shelf 2 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block, if applicable. (See Note 1.) LINE T1-5 (SECB-2) wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Slate Pair Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 5, if applicable. (See Note 2.) Goes to URC or URC-II, Position 2. 25 pin, D-sub pin # Tx T 5-5 Upper Tx R 5-5 Lower Rx T 5-6 Upper 22 Rx R 5-6 Lower 21 Tx T 5-7 Upper 11 Tx R 5-7 Lower 10 Rx T 5-8 Upper 25 Rx R 5-8 Lower 24 Notes: 1. Only Voice T1/E1 lines may be assigned to Z-IDC Punchdown Block 5 (URC or URC-II, Position 2). 2. EXAMPLE 5-3 Lower = Punchdown Block 5, Position 3, Lower 3. Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables, at the customer’s NIU, must not be looped back towards the BTS 8420 while the radio is in operation. 4. Use the T1-5 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. Voice only, Digital Shelf 2 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block by customer, if applicable. (See Note 1.) LINE T1-6 (User Relay) wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) White-Blue Pair Blue-White White-Orange Orange-White LINE White-Green Green-White White-Brown Brown-White Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 6, if applicable. (See Note 2.) URC or URC-II, Position 3. 25 pin, D-sub pin # Tx T 6-1 Upper Tx R 6-1 Lower Rx T 6-2 Upper 16 Rx R 6-2 Lower 15 Tx T 6-3 Upper Tx R 6-3 Lower Rx T 6-4 Upper 19 Rx R 6-4 Lower 18 .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-38 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect T1/E1 cables to BTS 8420/AWS 8420 radio cabinet Voice only, Digital Shelf 2 Customer assigned T1/E1 Line Number. Cable to be punched down at Equipment side of Z-IDC block by customer, if applicable. (See Note 1.) T1-6 (User Relay) wire color code. To be punched down at customer provided punchdown block at NIU. (See Note 4.) LINE White-Slate Pair Slate-White Red-Blue Blue-Red LINE Red-Orange Orange-Red Red-Green Green-Red Function Tx/Rx Tip/Ring Equipment side of Z-IDC punchdown block 6, if applicable. (See Note 2.) URC or URC-II, Position 3. 25 pin, D-sub pin # Tx T 6-5 Upper Tx R 6-5 Lower Rx T 6-6 Upper 22 Rx R 6-6 Lower 21 Tx T 6-7 Upper 11 Tx R 6-7 Lower 10 Rx T 6-8 Upper 25 Rx R 6-8 Lower 24 Notes: 1. Only Voice T1/E1 lines may be assigned to Punchdown Block 6 (URC or URC-II, Position 3). 2. EXAMPLE 6-3 Lower = Block Number 6, Position 3, Lower 3. Z-IDC positions 9 and 10 are not used. Unused T1/E1 cables, at the customer’s NIU, must not be looped back towards the BTS 8420 while the radio is in operation. 4. Use the T1-6 cable wire color code accordingly to punch down T1 cable (depends upon number of T1s available) at customer provided punchdown block on NIU. END OF STEPS ................................................................................................................................................................................................... .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-39 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................................................... Overview This topic provides instructions for routing and connecting the User Alarm cable (external and power, if applicable) to the BTS 8420/AWS 8420 radio cabinet. Each indoor User Alarm cable consists of 16 twisted-wire pairs. The end, which is terminated with a 37-pin D-sub, is connected to the BTS 8420/AWS 8420 radio cabinet. The loose (not terminated) end is punched down at the NIU. Connect User Alarm cable(s) to BTS 8420/AWS 8420 radio cabinet with integrated power Perform the following steps when connecting User Alarm cable(s) to the BTS 8420/AWS 8420 radio cabinet with integrated power. ................................................................................................................................................................................................... For the AWS 8420 and all versions of the BTS 8420 radio cabinet with integrated power (except the BTS 8420 Digital Only version with two Digital Shelves), locate the two User Alarm cable(s) shipped with the cabinet. Mark the first cable “Alarms 0-15” at both ends. Mark the second cable (if there is one) with “Alarms 16-31“ at both ends. For configurations with non-Alcatel-Lucent power, connect the “Alarms 16-31” cable to the bracket on top of the Integrated Power Module. Refer to the figure below. For the BTS 8420 Digital Only version with two Digital Shelves radio cabinet with integrated power, locate the two User Alarm cable(s) shipped with the cabinet. Mark the first cable “Alarms 0-15” at both ends. Mark the second cable (if there is one) “Alarms 16-31“ at both ends. Connect the “Alarms 0-15” cable to the USER ALARMS 0-15 connector on the Integrated Power Module bracket. Connect the “Alarms 16-31” cable to the USER ALARMS 16-31 connector on the Integrated Power Module bracket. Refer to the figure below. ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-40 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet CONNECT 16-31 ALARM CABLE HERE (SECB2) CONN 5 (SECB1) CONN 4 CONNECT 0-15 ALARM CABLE HERE USER ALARMS 16-31 USER ALARMS 0-15 FRONT OF CABINET ................................................................................................................................................................................................... Route the User Alarm cable(s) to the location of the punchdown block (or equivalent). Important! Secure the cable to the ladder rack in accordance with standard procedures, when performing the next step. Be sure to use cable ties. ................................................................................................................................................................................................... Tie the User Alarm cable(s) to the ladder rack, as shown in the figure below. (This figure applies to BTS 8420 and AWS 8420 radio cabinets.) .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-41 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet PUNCHDOWN BLOCK OR EQUIVALENT USER ALARM CABLE TIE CABLE TO LADDER RACK HORIZONTAL LADDER RACK TO BRACKET ON INTEGRATED POWER MODULE INTEGRATED POWER MODULE BTS 8420 RADIO CABINET E................................................................................................................................................................................................... ND OF STEPS .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-42 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet Connect User Alarm cable(s) to BTS 8420/AWS 8420 radio cabinet without integrated power Perform the following steps when connecting the User Alarm cable(s) to the BTS 8420/AWS 8420 radio cabinet without integrated power. ................................................................................................................................................................................................... For BTS 8420/AWS 8420 radio cabinets without integrated power only, locate the User Alarm cable(s) that are shipped with the cabinet. Label the first cable “Alarms 16-31” at both ends. Label the second cable “Alarms 0-15” at both ends. Connect the “Alarms 16-31” cable to the Universal Hatchplate on the BTS 8420/AWS 8420 radio cabinet. If using non-Alcatel-Lucent power, connect only “Alarms 0-15” cable to the Universal Hatchplate on the BTS 8420/AWS 8420 radio cabinet. Refer to the figure of the Universal Hatchplate below. FRONT ................................................................................................................................................................................................... Route the User ASlarm cable(s) to the location of the punchdown block(s) or equivalent. Important! Secure the cable to the ladder rack using standard procedures when performing the next step. Be sure to use cable ties. ................................................................................................................................................................................................... Tie the User Alarm cable(s) to the ladder rack, as shown in the figure below. (This figure applies to BTS 8420 and AWS 8420 radio cabinets.) .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-43 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet PUNCHDOWN BLOCK OR EQUIVALENT USER ALARM CABLE TIE CABLE TO LADDER RACK HORIZONTAL LADDER RACK TO UNIVERSAL HATCHPLATE BTS 8420 RADIO CABINET E................................................................................................................................................................................................... ND OF STEPS .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-44 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet Connect User Alarm cable(s) to Z-IDC punchdown block(s) (or equivalent) -- for all BTS 8420/AWS 8420 radio cabinets except Digital Only version with two Digital Shelves. Important! Z-IDC punchdown blocks are used only if the NIU is located more than the 10 meter (33 foot) cable length distance from the BTS 8420/AWS 8420. Otherwise, User Alarm connections are made directly to the NIU. The customer may use the Z-IDC (or NIU) to collect alarm cables from various locations. Use the following steps only if connecting to a Z-IDC. Otherwise, use only the tables to determine how to make connections at NIU. Use the following procedure to connect the User Alarm cables (External Alarms and Power Alarms, if applicable) to the punchdown terminals on the EQUIPMENT side of the Z-IDC punchdown block(s) (or equivalent), located at the NIU. (Refer to the figure on Page 5-11 for a simplified wiring diagram of User Alarm cabling from the Z-IDC punchdown blocks to the BTS 8420/AWS 8420 radio cabinet.) ................................................................................................................................................................................................... Locate the cables labeled “Alarms 0-15” and “Alarms 16-31,” and Z-IDC punchdown blocks 7,8,9,10 on the NIU. User Alarms 0-6 are connected to Z-IDC punchdown block 7, User Alarms 7-15 are connected to Z-IDC punchdown block 8, User Alarms 16-23 are connected to Z-IDC punchdown block 9, and User Alarms 24-31 are connected to Z-IDC punchdown block 10. (Refer to the figure on page 5-12 for the location of the punchdown blocks.) ................................................................................................................................................................................................... Route each User Alarm cable to its corresponding Z-IDC punchdown block and then through the cable strain relief clip on top of the Z-IDC punchdown block. Refer to the figure in the next step. ................................................................................................................................................................................................... Remove sufficient cable insulation and drain shield so the wires inside the cable reach the terminals on the punchdown block. Refer to the figure below. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-45 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet THREAD THE CABLE, IN THE DIRECTION SHOWN, THROUGH THE STRAIN RELIEF CLIP AT THE TOP OF THE BLOCK WIRE TIE THE CABLE TO THE STRAIN RELIEF CLIP AS SHOWN GROUNDING LUG AND #6 AWG PIGTAIL FROM HALO GROUND (Part of site preparation) 10 10 LEFT SIDE VIEW FRONT VIEW INSULATION, SHIELD, AND DRAIN WIRE REMOVED The connectorized end of Indoor T1/E1 and user alarm cable shields are bonded to the radio cabinet hatch plate via the D-sub connector. ................................................................................................................................................................................................... Route the individual wires down and along the side of the Z-IDC punchdown block (closest to the punchdown block terminals) where the connections will be made. ................................................................................................................................................................................................... Fan out the wires to the punchdown positions. (Be sure to leave plenty of slack.) .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-46 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... WARNING Equipment Damage Z-IDC punchdown tool (ITE No. R-6097) must be used when performing the next step. Use of any other tool will damage the Z-IDC punchdown block. Position the punchdown tool (ITE No. R-6097) so that the cutter faces the middle of the Z-IDC punchdown block. Refer to the figure below. ................................................................................................................................................................................................... Refer to the figure on page 5-12 and the tables in Step 9. Connect User Alarm twisted-wire pairs 0-6, 7-15, 16-23 and 24-31, as follows: • • • • Connect Power Alarm twisted-wire pairs 0-6 to the EQUIPMENT SIDE (see figure below) of punchdown block 7. These go to terminals 1-7 on the punchdown block. Connect User Alarm twisted-wire pairs 7-15 to the EQUIPMENT SIDE (see figure below) of punchdown block 8. These go to terminals 1-9 on the punchdown block. Connect User Alarm twisted-wire pairs 16-23 to the EQUIPMENT SIDE (see figure below) of punchdown block 8. These go to terminals 1-8 on the punchdown block. Connect User Alarm twisted-wire pairs 24-31 to the EQUIPMENT SIDE (see figure below) of punchdown block 9. These go to terminals 1-8 on the punchdown block. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-47 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet REAR (NETWORK SIDE) How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 10 10 FRONT (EQUIPMENT SIDE) Important! Punchdown connections 0-15 do not apply to the 3GP24i power cabinet. They are used only with non-Alcatel-Lucent power. ................................................................................................................................................................................................... Cut off any excess wire. ................................................................................................................................................................................................... The table below lists the connections for User Alarms 0-15 (power and external User Alarms) to be made to the EQUIPMENT SIDE of Z-IDC punchdown blocks 7 and 8. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-48 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 0-15 Alarm Cable/ connector at BTS 8420/AWS 8420 radio cabinet Alarm Punchdown Block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm cable wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Alarms 0-6 (37-Pin D-Sub) Z-IDC block 7. Power alarms for non-Alcatel-Lucent power only. (Punch downs not made for cabinets with integrated power.) Power 0 Alarm 7-1 Upper White-Blue 7-1 Lower Blue-White 20 7-2 Upper White-Orange 7-2 Lower Orange-White 21 7-3 Upper White-Green 7-3 Lower Green-White 22 7-4 Upper White-Brown 7-4 Lower Brown-White 23 7-5 Upper White-Slate 7-5 Lower Slate-White 24 7-6 Upper Red-Blue 7-6 Lower Blue-Red 25 7-7 Upper Red-Orange 7-7 Lower Orange-Red 26 Power 1 Alarm Power 2 Alarm Power 3 Alarm Power 4 Alarm Power 5 Alarm Power 6 Alarm .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-49 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 0-15 Alarm Cable/ connector at BTS 8420/AWS 8420 radio cabinet Alarm Punchdown Block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm cable wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Alarms 7-15 (37-Pin D-Sub) Z-IDC block 8, external User Alarms User 7 Alarm 8-1 Upper Red-Green 8-1 Lower Green-Red 27 8-2 Upper Red-Brown 8-2 Lower Brown-Red 28 8-3 Upper Red-Slate 10 8-3 Lower Slate-Red 29 8-4 Upper Black-Blue 11 8-4 Lower Blue-Black 30 8-5 Upper Black-Orange 12 8-5 Lower Orange-Black 31 8-6 Upper Black-Green 13 8-6 Lower Green-Black 32 8-7 Upper Black-Brown 14 8-7 Lower Brown-Black 33 8-8 Upper Black-Slate 15 8-8 Lower Slate-Black 34 8-9 Upper Yellow-Blue 16 8-9 Lower Blue Yellow 35 User 8 Alarm User 9 Alarm User 10 Alarm User 11 Alarm User 12 Alarm User 13 Alarm User 14 Alarm User 15 Alarm The following table lists the User Alarm connections 16-31 (external only) at the EQUIPMENT SIDE of Z-IDC punchdown blocks 9 and 10. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-50 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 16-31 Alarm Cable/ Connector on BTS 8420/AWS 8420 radio cabinet Alarm punchdown block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Alarms 16-23 (37-Pin D-Sub) Z-IDC block 9, external User Alarms User 16 Alarm 9-1 Upper White-Blue 9-1 Lower Blue-White 20 9-2 Upper White-Orange 9-2 Lower Orange-White 21 9-3 Upper White-Green 9-3 Lower Green-White 22 9-4 Upper White-Brown 9-4 Lower Brown-White 23 9-5 Upper White-Slate 9-5 Lower Slate-White 24 9-6 Upper Red-Blue 9-6 Lower Blue-Red 25 9-7 Upper Red-Orange 9-7 Lower Orange-Red 26 9-8 Upper Red-Green 9-8 Lower Green-Red 27 User 17 Alarm User 18 Alarm User 19 Alarm User 20 Alarm User 21 Alarm User 22 Alarm User 23 Alarm .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-51 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 16-31 Alarm Cable/ Connector on BTS 8420/AWS 8420 radio cabinet Alarm punchdown block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Alarms 24-31 (37-Pin D-Sub) Z-IDC block 10, external User Alarms User 24 Alarm 10-1 Upper Red-Brown 10-1 Lower Brown-Red 28 10-2 Upper Red-Slate 10 10-2 Lower Slate-Red 29 10-3 Upper Black-Blue 11 10-3 Lower Blue-Black 30 10-4 Upper Black-Orange 12 10-4 Lower Orange-Black 31 10-5 Upper Black-Green 13 10-5 Lower Green-Black 32 10-6 Upper Black-Brown 14 10-6 Lower Brown-Black 33 10-7 Upper Black-Slate 15 10-7 Lower Slate-Black 34 10-8 Upper Yellow-Blue 16 10-8 Lower Blue Yellow 35 User 25 Alarm User 26 Alarm User 27 Alarm User 28 Alarm User 29 Alarm User 30 Alarm User 31 Alarm E................................................................................................................................................................................................... ND OF STEPS Connect User Alarm cable(s) to Z-IDC punchdown block(s) (or equivalent) -- for BTS 8420 Digital Only version with two Digital Shelves. Important! Z-IDC punchdown blocks are used only if the NIU is located more than the 10 meter (33 foot) cable length distance from the BTS 8420. Otherwise, User Alarm connections are made directly to the NIU. The customer may use the Z-IDC (or NIU) to collect alarm cables from various locations. Use the following steps only if connecting to a Z-IDC. Otherwise, use only the tables to determine how to make connections at NIU. Use the following procedure to connect User Alarm cables (i.e., external User Alarms and Power Alarms) to the punchdown terminals on the EQUIPMENT side of the Z-IDC punchdown block(s), or equivalent, on the NIU. Refer to the figure on page 5-12 for a simplified wiring diagram of the User Alarm cabling from the Z-IDC punchdown blocks to the BTS 8420 radio cabinet with two Digital Shelves. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-52 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... Locate the cables labeled “Alarms 0-15” and “Alarms 16-31,” and Z-IDC punchdown blocks 7,8,9,10 on the NIU. User Alarms 0-6 are connected to Z-IDC punchdown block 7, User Alarms 8-15 are connected to Z-IDC punchdown block 8, and User Alarms 23-31 are connected to Z-IDC punchdown block 10. (Refer to the figure on page 5-13 for the location of the punchdown blocks.) ................................................................................................................................................................................................... Route each User Alarm cable to its corresponding Z-IDC punchdown block and then through the cable strain relief clip on top of the Z-IDC punchdown block. Refer to the figure in the next step. ................................................................................................................................................................................................... Remove sufficient cable insulation and drain shield so the wires inside the cable reach the terminals on the punchdown block. Refer to the figure below. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-53 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet THREAD THE CABLE, IN THE DIRECTION SHOWN, THROUGH THE STRAIN RELIEF CLIP AT THE TOP OF THE BLOCK WIRE TIE THE CABLE TO THE STRAIN RELIEF CLIP AS SHOWN GROUNDING LUG AND #6 AWG PIGTAIL FROM HALO GROUND (Part of site preparation) 10 10 LEFT SIDE VIEW FRONT VIEW INSULATION, SHIELD, AND DRAIN WIRE REMOVED The connectorized end of Indoor T1/E1 and user alarm cable shields are bonded to the radio cabinet hatch plate via the D-sub connector. ................................................................................................................................................................................................... Route the individual wires down and along the side of the Z-IDC punchdown block (closest to the punchdown block terminals) where the connections will be made. ................................................................................................................................................................................................... Fan out the wires to the punchdown positions. (Be sure to leave plenty of slack.) .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-54 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet ................................................................................................................................................................................................... WARNING Equipment Damage Z-IDC punchdown tool (ITE No. R-6097) must be used when performing the next step. Use of any other tool will damage the Z-IDC punchdown block. Position the Z-IDC punchdown tool (ITE No. R-6097) so the cutter faces the middle of the Z-IDC punchdown block. Refer to the figure below. ................................................................................................................................................................................................... Refer to the figure on page 5-13 and the tables in Step 9. Connect the 0-6, 7-15, and 23-31 User Alarm twisted-wire pairs as follows: • • • • Connect User Alarm twisted-wire pairs 0-6 to the EQUIPMENT SIDE (see figure below) of punchdown block 7. These go to terminals 1-7 on the punchdown block. Connect User Alarm twisted-wire pairs 7-15 to the EQUIPMENT SIDE (see figure below) of punchdown block 8. These go to terminals 1-9 on the punchdown block. If applicable, connect Power Alarm twisted-wire pairs 16-22 to the EQUIPMENT SIDE (see figure below) of punchdown block 9. These go to terminals 1-7 on the punchdown block. (These Power Alarms are for non-Alcatel-Lucent power only. Punch downs are not made for cabinets with integrated power.) Connect User Alarm twisted-wire pairs 23-31 to the EQUIPMENT SIDE (see figure below) of punchdown block 10. These go to terminals 1-9 on the punchdown block. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-55 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet REAR (NETWORK SIDE) How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 10 10 FRONT (EQUIPMENT SIDE) Important! Punchdown connections 0-15 do not apply to the 3GP24i power cabinet. They are used only with non-Alcatel-Lucent power. ................................................................................................................................................................................................... Cut off any excess wire. ................................................................................................................................................................................................... The following table lists the connections (to the EQUIPMENT SIDE of Z-IDC punchdown blocks 7 and 8) for User Alarms 0-15. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-56 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 0-15 Alarm Cable/ Connector at BTS 8420 Radio Cabinet Alarm Punchdown Block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Alarms 0-15 (37-Pin D-Sub) Z-IDC block 7 Power alarms (Non-AlcatelLucent power only). Punch downs not made for integrated power. Power 0 Alarm 7-1 Upper White-Blue 7-1 Lower Blue-White 20 7-2 Upper White-Orange 7-2 Lower Orange-White 21 7-3 Upper White-Green 7-3 Lower Green-White 22 7-4 Upper White-Brown 7-4 Lower Brown-White 23 7-5 Upper White-Slate 7-5 Lower Slate-White 24 7-6 Upper Red-Blue 7-6 Lower Blue-Red 25 7-7 Upper Red-Orange 7-7 Lower Orange-Red 26 Power 1 Alarm Power 2 Alarm Power 3 Alarm Power 4 Alarm Power 5 Alarm Power 6 Alarm .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-57 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 0-15 Alarm Cable/ Connector at BTS 8420 Radio Cabinet Alarm Punchdown Block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Alarms 0-15 (37-Pin D-Sub) Z-IDC BLOCK 8 External User Alarms User 7 Alarm 8-1 Upper Red-Green 8-1 Lower Green-Red 27 8-2 Upper Red-Brown 8-2 Lower Brown-Red 28 8-3 Upper Red-Slate 10 8-3 Lower Slate-Red 29 8-4 Upper Black-Blue 11 8-4 Lower Blue-Black 30 8-5 Upper Black-Orange 12 8-5 Lower Orange-Black 31 8-6 Upper Black-Green 13 8-6 Lower Green-Black 32 8-7 Upper Black-Brown 14 8-7 Lower Brown-Black 33 8-8 Upper Black-Slate 15 8-8 Lower Slate-Black 34 8-9 Upper Yellow-Blue 16 8-9 Lower Blue Yellow 35 User 8 Alarm User 9 Alarm User 10 Alarm User 11 Alarm User 12 Alarm User 13 Alarm User 14 Alarm User 15 Alarm The following table lists the connections (external only), to the EQUIPMENT side of Z-IDC punchdown block 10, for User Alarms 16-31. (User Alarms 16-22 are not available for integrated power.) .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-58 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet 16-31 Alarm cable/ Connector onBTS 8420 radio cabinet Alarm punchdown block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Alarms 16-22 (37-Pin D-Sub) Z-IDC block 7 Power alarms for non-Alcatel-Lucent power only. Punch downs not made for cabinets with integrated power. Power 16 Alarm 9-1 Upper White-Blue 9-1 Lower Blue-White 20 Power 17 Alarm 9-2 Upper White-Orange 9-2 Lower Orange-White 21 Power 18 Alarm 9-3 Upper White-Green 9-3 Lower Green-White 22 Power 19 Alarm 9-4 Upper White-Brown 9-4 Lower Brown-White 23 Power 20 Alarm 9-5 Upper White-Slate 9-5 Lower Slate-White 24 Power 21 Alarm 9-6 Upper Red-Blue 9-6 Lower Blue-Red 25 Power 22 Alarm 9-7 Upper Red-Orange 9-7 Lower Orange-Red 26 .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-59 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet 16-31 Alarm cable/ Connector onBTS 8420 radio cabinet Alarms 23-31 (37-Pin D-Sub) How to route and connect User Alarm cable(s) to indoor BTS 8420/AWS 8420 radio cabinet Alarm punchdown block (Z-IDC or equivalent) Alarm # Punchdown position at Equipment side of punchdown block. (Z-IDC block and position.) See Note. Alarm wire color code. To be punched down at customer provided punchdown block at NIU. Pin # at 37-Pin D-Sub Z-IDC BLOCK 10 External User Alarms User 23 Alarm 10-1 Upper Red-Green 10-1 Lower Green-Red 27 10-2 Upper Red-Brown 10-2 Lower Brown-Red 28 10-3 Upper Red-Slate 10 10-3 Lower Slate-Red 29 10-4 Upper Black-Blue 11 10-4 Lower Blue-Black 30 10-5 Upper Black-Orange 12 10-5 Lower Orange-Black 31 10-6 Upper Black-Green 13 10-6 Lower Green-Black 32 10-7 Upper Black-Brown 14 10-7 Lower Brown-Black 33 10-8 Upper Black-Slate 15 10-8 Lower Slate-Black 34 10-9 Upper Yellow-Blue 16 10-9 Lower Blue Yellow 35 User 24 Alarm User 25 Alarm User 26 Alarm User 27 Alarm User 28 Alarm User 29 Alarm User 30 Alarm User 31 Alarm END OF STEPS ................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-60 Connecting cables to BTS 8420/AWS 8420 radio cabinet Balun block connections (if applicable) Overview ................................................................................................................................................................................................................................... Purpose This section describes how to connect T1/E1 lines when a Balun Block is used. In the event the Balun Blocks provided to the customer are Alcatel-Lucent Balun Blocks, instructions are provided to the installer for installing and connecting one to three T1/E1 cables from the BTS 8420/AWS 8420 radio cabinet to one to three Balun Blocks. The Balun Blocks must be located within the 10 meter (33 foot) cable length distance from the BTS 8420/AWS 8420 radio cabinet. Four loose RJ-45 connectors (shipped with the Balun Block) must be connected to the end of the T1/E1 cables that connect to the Balun Block. Contents How to connect twisted-wire pairs in T1/E1 cable(s) to Balun Blocks 5-62 ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-61 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to connect twisted-wire pairs in T1/E1 cable(s) to Balun Blocks ................................................................................................................................................................................................................................... Before you begin This module provides instructions to the installer for installating and connecting one to three T1/E1 cables from the BTS 8420/AWS 8420 radio cabinet to one to three Balun Blocks. (The Balun Blocks are customer provided and installed.) “Connect RJ-45 connectors to twisted-wire pairs in T1/E1 cable(s) ” (p. 5-64) “Connect RJ-45 connectors to Balun Blocks” (p. 5-66) Balun Block description The customer is responsible for converting 75 ohm unbalanced coaxial cable to 120 ohm balanced twisted pair if the incoming facility provides 75 ohm unbalanced coaxial cable. Conversion of 75 ohm unbalanced coaxial cable to 120 ohm balanced twisted pair is accomplished with an Alcatel-Lucent Balun Block, or equivalent. Important! The Balun Block must be installed within the 10 meter (33 foot) cable length from the BTS 8420/AWS 8420 radio cabinet. The T1/E1 cable is connected directly to the Balun Block. Four RJ-45 loose connectors are provided with each Balun block and must be installed on each T1/E1 cable that goes from the BTS 8420/AWS 8420 to the Balun Block, during installation of the BTS 4400 radio cabinet. Refer to the figure below. T1/E1 input lines (From Service Provider) NIU with primary Protection (Provided by customer) T1/E1 lines to Balun Block (Provided as part (Coaxial cable) of site preparation) Balun Block (See Notes 1 and 2) T1/E1 cable (See Note 3) To BTS 8420/AWS 8420 radio cabinet. [Maximum distance = 10 meter (33 foot) cable length.] Note 1: Z-IDC block not required when Balun Block is used. Note 2: Balun Block must be located not more than the 10 meter (35 foot) cable length distance from radio cabinet. Note 3: RJ-45 connectors installed on loose end of T1/E1 cables and connected to Balun Block during installation of radio cabinet. ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-62 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to connect twisted-wire pairs in T1/E1 cable(s) to Balun Blocks The Step 7 table that follows, provides punchdown and wire color code information for the T1/E1 cable that is to be connected from the Balun Block to the BTS 8420/AWS 8420 radio cabinet. The customer must label each Balun Block with the cable name of the cable that is to be connected to it. The table notes in the table that follows describe the three cable possibilities (one Balun Block is required for each T1/E1 cable) and URC/URCII, Voice, and Data assignments. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-63 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to connect twisted-wire pairs in T1/E1 cable(s) to Balun Blocks Connect RJ-45 connectors to twisted-wire pairs in T1/E1 cable(s) The following figure shows the RJ-45 connector and its pins, which are numbered. Use the following procedure to attach four RJ-45 connectors to the eight twisted-wire pair in the T1-1 (first) T1/E1 cable (two twisted-wire pairs connect to each RJ-45 connector). ................................................................................................................................................................................................... Locate the cable marked T1-1 and the Balun Block for cable T1-1. (This was assigned by the customer during site preparation.) ................................................................................................................................................................................................... Obtain the four RJ-45 connectors supplied with the Balun Block. Important! When performing the next step, use RJ-45 connector crimping tool R-5520 to connect the twisted-wire pairs to the RJ-45 connectors. ................................................................................................................................................................................................... Consult the Step 7 table below for twisted-wire pair color codes. Connect each twisted-wire pair to the first RJ-45 connector, as follows • • • • White-Blue to Pin 1 Blue-White to Pin 2 White-Orange to Pin 4 (Do not use pin 3) Orange-White to Pin 5 If unsure of a color code, refer to the ”25-pin, D-sub pin number” column in the Step 7 table below. Then check for continuity. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-64 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to connect twisted-wire pairs in T1/E1 cable(s) to Balun Blocks ................................................................................................................................................................................................... Carefully mark this RJ-45 as “Connector 1.” ................................................................................................................................................................................................... Repeat steps 3 and 4 for the remaining three RJ-45 connectors. Observe correct color codes in table. Mark the connectors as follows: • • • “Connector 2” “Connector 3” “Connector 4” ................................................................................................................................................................................................... If applicable, locate the cable marked T1-2 and repeat Steps 2 through 5. ................................................................................................................................................................................................... If applicable, locate the cable marked T1-3 and repeat Steps 2 through 5. The following table provides the wire color codes for the twisted-wire pairs in the T1/E1 cable so the RJ-45 connectors can be connected to cables T1-1, T1-2 and T1-3. Cables T1-1, T1-2 and T1-3 are subsequently connected to the appropriate Balun Block. The table applies to the T1/E1 connections from the BTS 4400 radio cabinet to the Balun Block. E................................................................................................................................................................................................... ND OF STEPS .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-65 Issue 4, November 2007 See notice on first page Connecting cables to BTS 8420/AWS 8420 radio cabinet How to connect twisted-wire pairs in T1/E1 cable(s) to Balun Blocks Customer must label each Balun Block with cable name of cable that will be connected to it Cable Name (With URC/ URCII and Voice/Data assignments) Connector number on RJ-45 Balun Block Pin number on RJ-45 connector Color codes for twisted-wire pairs Pin number on 25-pin, D-sub connector Cables: White-Blue Blue-White White-Orange 16 Orange-White 15 White-Green Green-White White-Brown 19 Brown-White 18 White-Slate Slate-White Red-Blue 22 Blue-Red 21 Red-Orange 11 Orange-Red 10 Red-Green 25 Green-Red 24 • T1-1 • T1-2 • T1-3 Refer to Note 1 below, for URC/URCII and Voice/Data assignments by cable name. Note 1: The three cable possibilities (one Balun Block per cable) and URC/URCII, Voice, and Data assignments are as follows: • Cable T1-1, URC/URCII, Position 1, Data or Voice, Mutually exclusive • Cable T1-2, URC/URCII, Position 2, Voice Only • Cable T1-3, URC/URCII, Position 3, Voice Only Connect RJ-45 connectors to Balun Blocks Use the following procedure to connect four RJ-45 connectors in the T1 cables to the Balun Block. ................................................................................................................................................................................................... Refer to the above table for Balun Block connections. ................................................................................................................................................................................................... Connect four previously labeled T1-1 cable RJ-45 connectors to corresponding RJ-45 jacks on Balun Block. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 5-66 Connecting cables to BTS 8420/AWS 8420 radio cabinet How to connect twisted-wire pairs in T1/E1 cable(s) to Balun Blocks ................................................................................................................................................................................................... Repeat the previous step for cables T1-2 and T1-3, if applicable. END OF STEPS ................................................................................................................................................................................................... .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 5-67 Issue 4, November 2007 See notice on first page 6 P ower connections Overview ................................................................................................................................................................................................................................... Purpose This chapter provides instructions for connecting AC, DC, and customer-supplied power to the BTS 8420 radio cabinet with integrated power. (Note that the Integrated Power Module is field installed.) Procedures are provided for: • • • connecting customer-supplied power to a BTS 8420/AWS 8420 radio cabinet (references DC and alarm connections) connecting AC power to a BTS 8420/AWS 8420 radio cabinet with integrated power connecting first and second EZBFi battery frames to a BTS 8420/AWS 8420 radio cabinet with integrated power Installation of rectifiers in the Integrated Power Module is covered in Chapter 7, “Component installation in Integrated Power Module”. Installation of batteries in the EZBFi is covered in the EZBFi Modular Battery System Installation Manual for +24V and -48V, 401-703-507. Contents Customer-supplied power 6-2 Safety precautions 6-3 Power wiring overview 6-4 Installation of integrated power AC connections 6-5 Wiring overview 6-6 How to install the integrated power AC connections 6-7 ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 6-1 Issue 4, November 2007 See notice on first page Power connections Customer-supplied power Overview ................................................................................................................................................................................................................................... Purpose This section provides the references required for customer supplied power. References For AC/DC power and power system alarm requirements, refer to Appendix E in the Alcatel-Lucent CDMA Base Station BTS 8420/AWS 8420 Indoor Site Preparation Guidelines, 401-703-443. Refer to the applicable vendor documentation if the requirements listed in the applicable document have been met. Then use the chapter and page references given below for instructions to connect the indoor radio cabinet and external punchdowns, if applicable. Contents Safety precautions 6-3 Power wiring overview 6-4 ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 6-2 Power connections Safety precautions ................................................................................................................................................................................................................................... The following safety precautions should be read and understood before starting the installation of power cables. WARNING Electrical Energy Hazard Failure to follow the order of the installation procedure (as written) can result in an energized AC or DC circuit, which creates an electrical shock hazard. Follow these rules: 1. Perform installation steps in the order provided. 2. Do not connect AC power until instructed to do so. 3. When installing battery modules, do not connect battery disconnect cables on the battery retaining brackets until instructed to do so. 4. When installing battery modules, do not connect DC cables until instructed to do so. 5. Observe and strictly follow all additional safety precautions. 6. When completing electrical connections, always use tools that are properly insulated. CAUTION Damage to electronic components Handling of plug-in modules without the use of an ESD wrist strap can result in damage to electronic circuits. Always wear a properly grounded ESD strap and follow ESD procedures when handling any electronic components. ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 6-3 Issue 4, November 2007 See notice on first page Power connections Power wiring overview ................................................................................................................................................................................................................................... This chapter provides instructions for the power interconnections between the EZBFi battery frames and the integrated power module on the integrated power version of the radio cabinet, as well as the AC utility connection to the integrated power module. Refer to the figure below for a key to the following numbered list. 1. AC utility connection to the integrated power module 2. DC cable connections between the first EZBFi battery base module and the integrated power module 3. Fuse alarm cable connections between the first battery base module and the integrated power module (combined with #4) 4. Thermal probe cable connection between the battery base modules and the integrated power module (combined with #3) 5. DC cable connections between the first EZBFi battery base module and the second EZBFi battery base module. AC ADD-ONBATTERY THERMAL MODULE AS PROBE SECOND BASE CABLES MODULE DC IPM ADD-ON BATTERY MODULE ADD-ON BATTERY MODULE CDMA BASE STATION 8420 RADIO CABINET ADD-ON BATTERY MODULE ADD-ON BATTERY MODULE REAR VIEW ALARM SINGLE SHELF ADD-ON BATTERY MODULE FIRST BATTERY BASE MODULE * Power alarm connections to the radio cabinet were covered in Chapter 5. ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 6-4 Power connections Installation of integrated power AC connections Overview ................................................................................................................................................................................................................................... Purpose This section describes the instructions for making AC utility power connections to the BTS 8420/AWS 8420 radio cabinet having an Integrated Power Module. Note that grounding cables were installed in Chapter 4, “Transport, mount, and ground cabinet” after placement and anchoring of the BTS 8420 radio cabinet. Contents Wiring overview 6-6 How to install the integrated power AC connections 6-7 ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 6-5 Issue 4, November 2007 See notice on first page Power connections Wiring overview ................................................................................................................................................................................................................................... Wiring overview AC utility power input enters the Integrated Power Module on the top of the unit. AC power is connected to the AC terminal block. Refer to the following figure for an overview illustration. AC INPUT VIA 1 INCH CONDUIT OVERHEAD LADDER RACK INTEGRATED POWER MODULE FRAME GROUND AC TERMINAL BLOCK GROUNDING JUMPER RADIO CABINET WITH INTEGRATED POWER THERMAL PROBE CONNECTION LOCATION RECTIFIER SHELF ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 6-6 Power connections How to install the integrated power AC connections ................................................................................................................................................................................................................................... Overview This procedure module provides instructions for the connection of the AC utility power wires to a BTS 8420/AWS 8420 radio cabinet that is equipped with integrated power. Since this procedure may be performed by a licensed electrician (depending upon local regulations), these steps are supplied for reference only. If the AC utility connections are to be performed by a licensed electrician, this activity must be coordinated with the work of the BTS 8420 radio cabinet installers in order to avoid unnecessary delays. Step-by-step instructions are provided for the following tasks: “Connect 1-inch AC flexible metallic conduit to Integrated Power Module on top of BTS 8420/AWS 8420 radio cabinet” (p. 6-8) “Route and connect AC wires in Integrated Power Module” (p. 6-11) Safety precautions Observe the following safety precautions CAUTION Equipment Damage / Inspection Failure Damage to equipment, safety hazards, or failure to pass inspection can occur if all applicable codes and regulations are not followed. Follow all local codes and practices when performing the steps to connect AC to the Integrated Power Module. ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 6-7 Issue 4, November 2007 See notice on first page Power connections How to install the integrated power AC connections DANGER Electrical Energy Hazard Electrical circuits can become energized, resulting in an electrical shock hazard. Follow these rules: 1. Ensure that the circuit breaker for each AC input is turned OFF and tagged out. 2. Follow the procedures in the order provided. Always install earth ground connection before connecting AC power to the Integrated Power Module. Description of AC utility power connections The BTS 8420 radio cabinet described in this chapter is equipped with an Integrated Power Module. The Integrated Power Module accepts a 1-inch conduit (flexible metallic or rigid per local code) for the AC power supply wires. The AC wires enter through the top of the module. The Integrated Power Module is equipped with an AC terminal block at the top interior left side of the Integrated Power Module, for connecting the AC wires that power up to six rectifiers in the module. The customer provides the AC service and the flexible metallic conduit as part of site preparation. Before you begin The AC cable should be installed from the service panel to the area of the Integrated Power Module as part of site preparation. If this has not been done, contact your supervisor and the customer contact. Verify that the circuit breakers for the AC feeder wires are off, locked out, and tagged at the AC service panel. Verify that the GPS antenna, BTS 8420 radio cabinet and associated equipment have been properly grounded. Connect 1-inch AC flexible metallic conduit to Integrated Power Module on top of BTS 8420/AWS 8420 radio cabinet Use the following procedure to connect the 1-inch AC flexible metallic conduit to the Integrated Power Module on top of the cabinet. ................................................................................................................................................................................................... Locate the AC flexible metallic conduit connection access opening on the Integrated Power Module at the top of the BTS 8420 radio cabinet. Refer to the following figure. ................................................................................................................................................................................................... Locate the AC flexible metallic conduit, which is provided by the customer. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 6-8 Power connections How to install the integrated power AC connections ................................................................................................................................................................................................... Verify that the main panel breaker(s) that supply AC power are OFF and that clearly label (tag out) the circuit breaker panel, stating that installers are working on the AC wiring. ................................................................................................................................................................................................... Remove the AC terminal block cover from the Integrated Power Module by unscrewing the captivated Phillips head screw on the top. Refer to the following figure. * ONE INCH TRADE SIZE FLEXIBLE CONDUIT FITTING (FACTORY EQUIPPED) ................................................................................................................................................................................................... Thread the AC wires from the flexible metallic conduit and into the top of the Integrated Power Module through the access opening. Refer to the following figure. ................................................................................................................................................................................................... Attach the AC cable flexible metallic conduit to the top of the Integrated Power Module at the access opening. Refer to the following figure. .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 6-9 Issue 4, November 2007 See notice on first page Power connections How to install the integrated power AC connections E................................................................................................................................................................................................... ND OF STEPS .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 6-10 Power connections How to install the integrated power AC connections Route and connect AC wires in Integrated Power Module Use the following procedure to route and connect the AC wires in the Integrated Power Module. ................................................................................................................................................................................................... Verify that the main panel breaker(s) that supply AC power are OFF and that the panel has been clearly labeled (tagged out) stating that installers are working on the AC cabling. ................................................................................................................................................................................................... Route the AC wires and the grounding wire from the access opening, inside the top of the Integrated Power Module, and to the AC terminal block. ................................................................................................................................................................................................... Position the AC wires at the AC terminal block and cut them to length. ................................................................................................................................................................................................... Strip approximately 19 mm (3/4 inches) of insulation from the end of each wire. ................................................................................................................................................................................................... The location, color, function, and size of each wire in the AC input is shown in the table below. Use a small flat blade screwdriver, in each terminal insertion slot, to release each terminal input for insertion of the individual wires. Location/Color/Voltage Wire size Domestic - 208 - 240 VAC International - 230 VAC F1 L1 / Black F1 L1 / Brown 8 AWG F1 L2 / Red F1 N / Blue 8 AWG / Green/Yellow PE / Green/Yellow 8 AWG F2 L1 / Black F2 L1 / Brown 8 AWG F2 L2 / Red F2 N / Blue 8 AWG Function Circuit Feeder Line1 Branch Circuit 1 Ground Feeder Line2 -Branch Circuit 2 .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 6-11 Issue 4, November 2007 See notice on first page Power connections How to install the integrated power AC connections AC wiring compartment 1” trade size conduit Slot for insertion to release AC wire entry End user wire entry holes PE F2 L1 F2 L2/N F1 L1 F1 L2/N Label top of terminals Shelf wiring side (wires routed underneath terminals) Wiring to backplane Front Side wall of chassis ................................................................................................................................................................................................... Replace the AC access cover and tighten the screw. Refer to the Step 4 figure in Step 4 and the following figure. ................................................................................................................................................................................................... At the AC main distribution panel, check the label for each breaker. If they are not correct, relabel them to correspond to each circuit. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 6-12 Power connections How to install the integrated power AC connections Important! Do not turn on AC power at this time. END OF STEPS ................................................................................................................................................................................................... .................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 6-13 Issue 4, November 2007 See notice on first page 7 7 omponent installation in Integrated Power Module Overview ................................................................................................................................................................................................................................... Purpose This chapter provides instructions for installing rectifiers in the integrated power module. Contents How to install rectifiers in Integrated Power Module 7-2 ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 7-1 Issue 4, November 2007 See notice on first page Component installation in Integrated Power Module How to install rectifiers in Integrated Power Module ................................................................................................................................................................................................................................... Overview This procedure module provides instructions for installing the rectifiers in the integrated power module. Description of rectifiers and shelves The rectifiers are shipped separately if the radio cabinet is equipped with an integrated power module. You may want to refer to the installation instructions provided in the integrated power module kit (109601302) at this point. The integrated power module has one rectifier shelf. The rectifier shelf can support up to six KS-24734 rectifiers. The rectifiers must be installed, starting with Rectifier #1, as shown in the figure below. 24V POWER SHELF Facilities Circuit Breaker 10A [CB1] ON OFF Rect1 User panel: (1) 10A circuit breaker Rect2 Rect3 Rect4 Rect5 Rect6 6x KS-24734 Rectifier (1500 watts each) KS-24738 1500W Eac KS-2473 Controller ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 7-2 Component installation in Integrated Power Module How to install rectifiers in Integrated Power Module Preventing Equipment damage CAUTION ESD hazard Semiconductor elements can be damaged by static discharges. The following rules must be complied with when handling any module containing semiconductor components: • • • • • • • • • Wear conductive or antistatic working clothes (e.g., coat made of 100% cotton. Wear grounded ESD wrist strap. Wear shoes with conductive soles on a conductive floor surface or conductive work mat. Leave the modules in their original packaging until ready for use. Make sure there is no difference in potential between yourself, the workplace, and the package before removing, unpacking, or packing a module. Hold the module only by the grip without touching the connection pins, tracks, or components. Place modules removed from the equipment on a conductive surface. Test or handle the module only with grounded tools on grounded equipment. Handle defective modules exactly like new ones to avoid causing further damage. Number of required rectifiers Use the following procedure to install the KS-24734 rectifier(s) in the radio cabinet. The number of rectifiers is specified in the ERD and depends upon how many carriers there are. Install the rectifiers in the integrated power module Use the following procedure to install the rectifier(s) for the integrated power module on the radio cabinet. ................................................................................................................................................................................................... Insert, from left to right, the required number of rectifier modules KS-24734 that are needed to power the base station. Remove cover plates from slots 3 through 6, as needed. Secure each rectifier by turning the latch mechanism CW with a flat head screwdriver until it is fully seated. Do not over tighten. Refer to the figure below. ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 7-3 Issue 4, November 2007 See notice on first page Component installation in Integrated Power Module How to install rectifiers in Integrated Power Module 24V POWER SHELF Facilities Circuit Breaker 10A [CB1] ON OFF Rect1 User panel: (1) 10A circuit breaker Rect2 Rect3 Rect4 Rect5 6x KS-24734 Rectifier (1500 watts each) 1500W Eac Rect6 KS-24738 Controller KS-2473 Important! Proceed to the EZBFi Installation Manual to continue the installation. END OF STEPS ................................................................................................................................................................................................... ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 7-4 8 F inishing the installation Overview ................................................................................................................................................................................................................................... Purpose This chapter provides information for finishing the installation of the BTS 8420 radio cabinet and EZBFi battery modules. Contents General 8-2 Antenna connections 8-3 Initial start-up and system test 8-4 Install RF antenna jumper cables (indoor) 8-5 Finish installation of indoor BTS 8420/AWS 8420 radio cabinet 8-11 Final indoor BTS 8420/AWS 8420 radio cabinet installation procedures 8-12 ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 8-1 Issue 4, November 2007 See notice on first page Finishing the installation General Overview ................................................................................................................................................................................................................................... Purpose This section provides general information for finishing the installation of the BTS 8420/AWS 8420 radio cabinet. Contents Antenna connections 8-3 Initial start-up and system test 8-4 Install RF antenna jumper cables (indoor) 8-5 ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 8-2 Finishing the installation Antenna connections ................................................................................................................................................................................................................................... Verify GPS antenna connection Verify that the GPS antenna is properly connected, as outlined in Chapter 5 of this document. Verify that it meets all of the appropriate guidelines in accordance with the following documents: • • Alcatel-Lucent CDMA Base Station BTS 8420/AWS 8420 Indoor Site Preparation Guidelines, 401-703-443 Grounding and Lightning Protection Guidelines for Alcatel-Lucent Network Wireless System Cell Sites, 401-200-115 Important! The GPS antenna must be connected to the radio cabinet prior to “Initial start up and system test.” Refer to Chapter 5, “Connecting cables to BTS 8420/AWS 8420 radio cabinet”. Do not connect RF (Tx and Rx) antenna jumper cables. Verify RF antennas not connected The RF (Tx and Rx) antennas, if present, must not be connected until initial start-up and system test has been performed. ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 8-3 Issue 4, November 2007 See notice on first page Finishing the installation Initial start-up and system test ................................................................................................................................................................................................................................... Perform initial start-up and system test Initial start-up and system test can be performed if the following tasks are completed: • • • All cabinets are installed as specified in this document. The GPS antenna cable is connected. RF antenna jumper cables, if present, are not connected to the radio cabinet. Important! The procedures for initial start-up and testing are not covered in this document. Refer to CDMA Modcell and Base Station Integration Engineering Handbook (IEH 238). ................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 8-4 Finishing the installation Install RF antenna jumper cables (indoor) ................................................................................................................................................................................................................................... Important! It is recommended that the RF antenna jumper cables be connected to the BTS 8420 radio cabinet after the BTS 8420 radio cabinet power cabinet has been turned on and initial start-up and system test have been completed. Overview This procedure module provides instructions for installing the six RF antenna jumper cables at the BTS 8420/AWS 8420 radio cabinet. Contents Step-by-step instructions are provided for the following tasks: “Connect RF antenna jumper cables to BTS 8420/AWS 8420 radio cabinet” (p. 8-5) “Route and connect indoor RF antenna jumper cables to customer provided DAS” (p. 8-8) Description of indoor RF antenna jumper cables The BTS 8420 radio cabinet requires six RF antenna jumper cables. The RF antenna jumper cables will be attached to the six RF antenna connections at the top rear of the BTS 8420/AWS 8420 radio cabinet. Refer to figure after Step 5Step 5. Each RF antenna jumper cable connects directly to an assigned antenna connection at the customer provided DAS. Connect RF antenna jumper cables to BTS 8420/AWS 8420 radio cabinet Use the following procedure to connect the RF antenna jumper cables to the BTS 8420/AWS 8420 radio cabinet. ................................................................................................................................................................................................... Important! When performing the next step, note that right angle connectors may be used at the radio cabinet connections. The radio cabinet is provided with six RF antenna jumper cables, terminated on both ends with a straight DIN connector. Locate these cables in the RF antenna kit. ................................................................................................................................................................................................... Label each cable at both ends: S1D0, S1D1, S2D0, S2D1, S3D0, S3D1. ................................................................................................................................................................................................................................... 401-703-444 Alcatel-Lucent - Proprietary 8-5 Issue 4, November 2007 See notice on first page Finishing the installation Install RF antenna jumper cables (indoor) ................................................................................................................................................................................................... Connect the RF antenna jumper cable to the applicable connector on the radio cabinets. Refer to the figure below and Step 5. S3D1 S3D0 S2D1 S2D0 S1D1 S1D0 ................................................................................................................................................................................................... Torque the RF antenna jumper cable connections at the BTS 8420/AWS 8420 radio cabinet to 25 Nm (221 in-lb), using the method shown in the figure below. 221 - 250 lb-IN 25 - 30 N-m 32mm 22mm 22mm Important! When connecting/disconnecting a Alcatel-Lucent RF coaxial jumper cable assembly to/from any fixed panel mounted 7-16 DIN female receptacle, it is highly recommended that the cable assembly be connected/disconnected as shown in the figure below. Please note that the mating receptacle is not shown because it is a fixed and secured interface. Wrenches for connecting/disconnecting the mating RF coaxial jumper cable’s 7-16 DIN male plug, which is equipped with a rotating coupling nut, are required. .................................................................................................................................................................................................................................... Alcatel-Lucent - Proprietary 401-703-444 See notice on first page Issue 4, November 2007 8-6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 75 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:c82b4fb6-dbc3-404a-bf92-af03ea38ce1c Modify Date : 2008:07:03 13:59:56-04:00 Create Date : 2008:07:03 13:59:37-04:00 Metadata Date : 2008:07:03 13:59:56-04:00 Document ID : uuid:184944ee-f780-4624-8042-7b8cd6f58308 Format : application/pdf Title : Alcatel-Lucent CDMA Base Station 8420 Indoor Cabinet Installation Manual Creator : Alcatel-Lucent Author : Alcatel-Lucent Subject : Producer : LiPP 3.0.0EXIF Metadata provided by EXIF.tools