Nortech PD230TD236 Vehicle Detector User Manual 302UM0017 01a PD230 Enh NewHousing NoApprovalsPage

Nortech International (PTY) LTD Vehicle Detector 302UM0017 01a PD230 Enh NewHousing NoApprovalsPage

User Manual

  Nortech International (Pty) Ltd PO Box 4099  32A Wiganthorpe Road Willowton Hub  Pietermaritzburg Pietermaritzburg  3201 South Africa 3200 South Africa  Reg. No. 98/1095  Tel: (033) 345 3456   Int. Tel: +27 33 345 3456 Fax: (033) 394 6449  Int Fax: +27 33 394 6449 E-mail: mkt@nortech.co.za  URL: www.nortech.co.za                                                  PD230 Enhanced Vehicle Detector USER MANUAL        NORTECH INTERNATIONAL (PTY) LTD All rights reserved.  Copyright  © 2009 Document No.: 302UM0017_01a Date of issue: August 2010 This document is for information only and unless otherwise indicated it is not to form part of any contract.  In accordance with the manufacturer’s policy of continually updating and improving design, specifications contained herein are subject to alterations without notice.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 2 of 37   Table of Contents  1. INTRODUCTION........................................................................................................................5 2. TECHNICAL DATA ....................................................................................................................6 2.1 Functional Data..........................................................................................................................6 2.2 Electrical Data............................................................................................................................6 2.3 Environmental Data....................................................................................................................7 2.4 Mechanical Data ........................................................................................................................8 2.5 Approvals ...................................................................................................................................8 3. OPERATING INSTRUCTIONS..................................................................................................9 3.1 Hardware Set-up........................................................................................................................9 3.2 Switch Setting Selections...........................................................................................................9 3.2.1 Frequency Switch..............................................................................................................9 3.2.2 Sensitivity ..........................................................................................................................9 3.2.3 Automatic Sensitivity Boost.............................................................................................10 3.2.4 Presence Time ................................................................................................................10 3.2.5 Pulse / Presence .............................................................................................................10 3.2.6 Reset Switch ...................................................................................................................10 3.3 Internal Link Selection..............................................................................................................11 3.4 Power Fail (Option) ..................................................................................................................11 3.5 Front Panel Indicators..............................................................................................................11 4. PRINCIPLE OF OPERATION..................................................................................................13 4.1 Detector Tuning........................................................................................................................13 4.2 Detector Sensitivity ..................................................................................................................13 4.3 Modes of Operation .................................................................................................................14 4.3.1 Presence Mode ...............................................................................................................14 4.3.2 Pulse Mode......................................................................................................................14 4.3.3 AB Logic Presence Mode (Barrier Operation) ................................................................15 4.3.4 AB Logic Pulse Mode (Counting Logic) ..........................................................................17 4.4 Response Times ......................................................................................................................19 5. INSTALLATION GUIDE ...........................................................................................................20 5.1 Product Safety Requirements..................................................................................................20 5.2 Operational Constraints ...........................................................................................................20 5.2.1 Environmental Factors to Consider.................................................................................20 5.2.2 Crosstalk..........................................................................................................................21 5.2.3 Reinforcing ......................................................................................................................21 5.3 Loop and Feeder Material Specification ..................................................................................21 5.4 Sensing Loop Geometry ..........................................................................................................22 5.5 Loop Installation.......................................................................................................................22 6. CONFIGURATION...................................................................................................................25 6.1 PD231 Enhanced Detector : English .......................................................................................25 6.2 PD232 Enhanced Detector: English ........................................................................................26 6.3 PD234 Enhanced Detector: English ........................................................................................26 7. APPLICATIONS.......................................................................................................................27 8. CUSTOMER FAULT ANALYSIS .............................................................................................28 8.1 Fault Finding ............................................................................................................................28 8.2 DU100 – Detector Diagnostic Unit...........................................................................................29 8.2.1 Interpretation of the DU 100 readings.............................................................................29 8.2.1.1  Frequency.........................................................................................................................29 8.3 Functional Test.........................................................................................................................31 APPENDIX A - FCC ADVISORY STATEMENT .............................................................................32 APPENDIX B – INSTALLATION OUTDOORS ...............................................................................33 Appendix B.1 IEC 60950-22:2005 – Outdoor cabinet ..............................................................33 Appendix B.2 IEC 60950-22:2005 - Northern Europe ..............................................................33
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 3 of 37     Appendix B.3 IEC 60950-1:2005 – Overvoltage Category.......................................................33 APPENDIX C - REQUEST FOR TECHNICAL SUPPORT FORM .................................................34
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 4 of 37  WARNING: 1.  THIS UNIT MUST BE EARTHED !    WARNING: 2.  DISCONNECT POWER BEFORE  WORKING ON THIS UNIT !    WARNING: 3.  INSTALLATION AND OPERATION    BY SERVICE PERSONNEL ONLY !   WARNING: 4.  NO USER SERVICEABLE PARTS INSIDE.  ONLY SERVICE PERSONNEL MAY OPEN THE UNIT TO CHANGE INTERNAL SETTINGS!   WARNING: 5.  Always suspend traffic through the barrier area during installation and testing that may result in unexpected operation of the barrier   WARNING: 6.  USA  FCC Advisory Statement – Refer to Appendix A at the end of this document.   WARNING: 7.  Europe  Disposing of the product.  This electronic product is subject to the EU Directive 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE). As such, this product must not be disposed of at a local municipal waste collection point. Please refer to local regulations for directions on how to dispose of this product in an environmental friendly manner.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 5 of 37  1.  INTRODUCTION  The “PD230 Enhanced Two Channel Inductive Loop Vehicle Detector” is a dual channel microprocessor based detector designed specifically for parking and vehicle access control applications. The PD230 Enhanced detector has been designed using the latest technology in order to meet the requirements of a vast number of parking applications in terms of operating conditions. A number of internal functional options are available to the user.  The primary function of the detector is to detect vehicle presence by means of an inductance change caused by the vehicle passing over a wire loop buried under the road surface.                      The detector has been designed around the popular PD130 series of single channel detectors for ease of installation and convenience. The various modes are selected by changing the position of switches on the front of the unit.  The detector oscillator is multiplexed to eliminate any possibility of crosstalk between the loops connected to the detector.  The switches allow for different loop frequency settings, sensitivity settings and mode settings.  The unit has a number of internally selectable options for configuration of the relay outputs.  The PD230 Enhanced 2 Channel Vehicle Detector provides visual outputs (LED) on the front of the enclosure and relay change-over contacts at the 11 pin connector at the rear of the enclosure. The power LED indicates that the unit has been powered. The channel status LED’s below indicate that a vehicle is present over the loop and when there is a fault on the loop. The Presence relays are normally fail-safe and will close on a vehicle detect, loop failure or in the event of a power failure.  Available is an additional Power-fail function which enables a short (of up to ten minutes) power-fail, to have no effect on the operation of the detector when power is restored. The detector will revert to the same state as prior to power failure, when power is restored.   For additional information refer to the following documents:  Data Sheet - PD230 Enhanced 2 Ch Vehicle Detector   Document No. 302DS0002 Installation Leaflet          Document No. 879LF0006 Diagnostic Unit DU100 User Manual       Document No. 895UM0001  2/4 Ch Vehicle Detector Installation Guide    Document No. 879LF0006
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 6 of 37  2.  TECHNICAL DATA   2.1  Functional Data  Tuning        Fully automatic  Self-tuning range    20 to 1000 µH  Sensitivity      Four step switch selectable:          High     0.02% ∆ L/L          Medium-High  0.05% ∆ L/L          Medium-Low  0.10% ∆ L/L          Low    0.50% ∆ L/L  Frequency      Four step selectable:          Frequency dependent on loop size  Automatic Sensitivity Boost  Switch selectable  Modes        Output relays may operate in the Presence ( fail-safe ),          Pulse or Direction logic modes  Presence Time      Switch selectable:          Limited presence          Permanent presence  Pulse Output Duration    150/250 millisecond options  Response Times    100 milliseconds  Drift Compensation Rate   Approx. 1% ∆ L/L per minute  Visual Indication     1 x Power LED - Red          2 x Channel Status LEDs - Green  Relay Outputs      2 x Relays, User Configurable as Presence or Pulse outputs,  Normally Open (N/O) contacts (Opto-Isolated Outputs are available on request. MOQ applies)  Reset        Reset by push button on front of enclosure  Surge Protection    Loop isolation transformer, gas discharge tubes,   and Zener diode clamping on loop input  Power Fail (Option)  10 minutes memory retention of detector state on power failure.    2.2  Electrical Data   Power requirements    120V AC ± 10% 48 to 62Hz (PD231 models)           230V AC ± 10% 48 to 62Hz (PD232 models)           PD231 and PD232 models: 1.5 VA Maximum at 230V           12V - 10% to 24V + 10% DC/AC 48 to 62Hz (PD234 models)
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 7 of 37 PD234 models: 1 VA Maximum at 12V  Relay Contact Rating    2 x Relays rated - 5A @ 230 VAC For ambient temperatures above 60 °C De-rate the relay maximum current as per graph below                 Opto-Isolated Output rating  33 V 50 mA  Note - Opto-Isolated Outputs are available on request. MOQ applies     2.3  Environmental Data  Storage Temperature    -40°C to +85°C  Operating Temperature    -40°C to +70°C  Humidity       Up to 95% relative humidity without condensation  Circuit Protection    Conformal coating over the PCB and all components  IP Rating      IP 30. - This product MUST be installed in an enclosure
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 8 of 37 2.4  Mechanical Data  Housing material   ABS blend  Mounting Position    Shelf or DIN rail mounting  Connections      11-pin submagnal type ( JEDEC No. B11– 88 )  Size of Housing     78mm ( High ) x 41mm ( Wide ) x 80mm ( Deep )                              2.5  Approvals   C.E. Regulations  EN 301 489-3    Equipment Type: III               Class of Equipment: 2        EN 50293    Performance Criteria B   Safety:      IEC / EN 60950-1    80 mm75.9 mm77.7 mm40.6 mm
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 9 of 37 3.  OPERATING INSTRUCTIONS  3.1  Hardware Set-up  The PD230 Enhanced dual channel parking detector is designed to be shelf or DIN rail mounted with the controls and visual indicators at the front and wiring at the rear of the enclosure.    The power, loop and relay outputs are all connected to the single 11-pin plug, which is mounted at the rear of the enclosure.  3.2  Switch Setting Selections   3.2.1  Frequency Switch   Where more than one detector is used at the same site, the detectors must be set-up to ensure that there is no CROSSTALK (interference) between adjacent loops connected to different detectors.   For more information about crosstalk refer to section 5.2.2.  The frequency switches are the lower two switches, numbered 1 and 2. There are four frequency selections and are set as follows:        The frequency switches allows the operating frequencies of the detector to be shifted higher or lower depending on the switch setting.  The operating frequency of the detector channel is determined by: Inductance of the loop and feeder cable Detector frequency switch settings  The operating frequency of the detector channel increases as the loop inductance decreases and vice versa.   The inductance of the loop and feeder cable is determined by:  Size of the loop Number of turns in the loop Length of feeder cable  As a general rule, the detector connected to the inductive loop with the greatest inductance should be set to operate at the lowest frequency.   When the frequency switch setting is altered, the operating frequency of both detector channels will shift. Because the unit has a common oscillator and the multiplexer connects the loops alternatively to this oscillator.  3.2.2  Sensitivity   The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce an output. There are four sensitivity selections and are set as follows: -  S1  S2  Frequency Setting Off  Off  High frequency Off  On  Medium-High frequency On  Off  Medium-Low frequency On  On  Low frequency
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 10 of 37  Channel1  Channel 2  S6  S5  S4  S3   Off   Off  Off  Off  High On  Off  On  Off  Medium-High Off  On  Off  On  Medium-Low On  On  On  On  Low  3.2.3  Automatic Sensitivity Boost  Automatic sensitivity boost is a mode which alters the undetect level of the detector. This mode is selected by switch No. 7 on the front of the enclosure and is set as follows: -  S7   Off   Disabled On  Enabled  Automatic sensitivity boost causes the sensitivity to be boosted to a maximum on detection of the vehicle, and maintained at this level during the presence of the entire vehicle over the loop. When the vehicle departs the loop and detection is lost the sensitivity reverts to the pre-selected level.  3.2.4  Presence Time   The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop. In limited presence mode there will be a finite time that the detector will remain in detect. This time is dependent on the change of inductance that the vehicle caused. The presence mode is set with switch No. 8 and is set as follows: -  S8  Off  Limited Presence On  Permanent Presence  3.2.5  Pulse / Presence   The channel’s relay may be set to either Pulse Mode or Presence Mode with switches No. 9 & No. 10 as shown in the table below: -  Channel1  Channel 2  S10  S9   Off  Off  Presence  On  On  Pulse   3.2.6  Reset Switch   The  detector  automatically  tunes  to  the  inductive  loops  connected  to  it  when  power  is  applied, whether  on  initial  installation  or  after  any  break  in  the  power  supply.  Should  it  be  necessary  to retune the detector, as may be required after the changing of any switch selections or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 11 of 37 3.3  Internal Link Selection  WARNING - ONLY SERVICE PERSONNEL MAY OPEN THE UNIT TO CHANGE INTERNAL SETTINGS!  There is one 3 way link located inside the PD230 Enhanced detector housing, which is used to alter the mode of operation of the detector. The link has been placed inside the unit to avoid incorrect operation due to selection by an unauthorised operator.                         For a description of the AB Logic mode refer to section 4.3 “Modes of Operation” below  For  the  PD230  Enhanced  parking  detector,  the  default  setting  for  both  channel  output  relays  is presence mode (Front panel switches 9 & 10 OFF) with no AB logic (i.e. no jumper on LK1).   3.4  Power Fail (Option)  Power-Fail-Option is available on request. MOQ applies  The detector (with  Power-Fail Option)  is able  to retain the  output state for a  power failure of  not greater than 10 minutes. Thus, when the power is restored, the detector will not re-tune but return to the detect state prior to the power failure. If a vehicle was on the loop during power failure, it will remain detected when power is restored.    3.5  Front Panel Indicators  While the detector is tuning, the Channel LED will indicate the “mode” status of the detector.  i) Any Channel output operating in the presence or pulse modes will come on and extinguish when the system is tuned.  ii) When the AB Logic mode is selected, the Channel LED’s will alternatively flash slow and extinguish when the system is tuned.  If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate and the LED will continue to show the historical fault. The detector must be reset or power removed to clear the historical fault information.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 12 of 37  The channel LED will also glow whenever a vehicle is detected passing over the inductive loop.  The Power LED at the top of the unit will remain on to indicate that the unit is powered. This LED is also used as the link to the diagnostic unit ( DU100 ).
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 13 of 37 4.  PRINCIPLE OF OPERATION  The inductive loop vehicle detector senses the presence of a vehicle over an area defined by a loop of two or more turns of wire laid under the road or pavement surface. This loop of wire is connected to the detector by a pair of wires called a loop feeder.    A vehicle passing over a sensing loop causes a small reduction in the inductance of the loop, which is sensed by the detector. The sensitivity of detection is adjustable to accommodate a wide range of vehicle types as well as different loop and feeder combinations.    Upon detection of a vehicle passing over the loop the detector operates its output relays which may be used to indicate controls associated with the installation.   4.1  Detector Tuning  Tuning of the detector is fully automatic. The detector will re-tune if any of the following events occur:-  - When power is applied to the detector. - A detector reset is initiated via the reset button.  - A detect of greater than 15% ∆ L/L occurs.  The detector will automatically tune each channel to its connected loop. The detector will tune to any loop in the inductance range of 20 to 1000 micro henries.    This wide range ensures that all loop sizes and feeder combinations will be accommodated in the tuning range of the detector.    Once tuned, any slow environmental change in loop inductance is fed to a compensating circuit within the detector, which keeps the detector correctly tuned.  4.2  Detector Sensitivity  Sensitivity of the detection system is dependent on factors such as loop size, number of turns in the loop, feeder length and the presence of metal reinforcing beneath the loop.   The nature of the application determines the required sensitivity, which may be adjusted by means of the front panel controls.    Sensitivity levels on the PD230 Enhanced detector have been carefully optimised for parking and vehicle access control applications. The detection of small, unwanted objects such as bicycles and trolleys can be eliminated by selecting lower sensitivity levels, whilst high-bed vehicles and vehicle/trailer combinations will not loose detection by using the Automatic Sensitivity Boost (ASB) option.  ASB operates as follows. When ASB is disabled the undetect level is dependent on the sensitivity setting of the detector. Hence as the detector is made less sensitive, the undetect level will be
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 14 of 37 reduced accordingly. When the ASB is enabled the undetect level will always be the same irrespective of the sensitivity setting and will be equivalent to the undetect level when the sensitivity is on maximum setting.  4.3  Modes of Operation  The PD230 Enhanced Detector may be configured for any one of the following modes:  Presence Mode Pulse Mode AB Logic Presence Mode (Barrier Operation) AB Logic Pulse Mode (Counting Logic)  4.3.1  Presence Mode    Link LK1 open  To set Channel 1 to Presence mode switch OFF switch 10  To set Channel 2 to Presence mode switch OFF switch 9    In the presence mode the detector channels operate independently  In the presence mode the detector will give a continuous output during the presence of a vehicle over the inductive loop. As the detector is designed with the permanent presence feature, the detector will indicate vehicle presence for an unlimited period of time.                The presence outputs are known as fail-safe outputs. This implies that in the event of a power failure or loop failure the detector will give detect outputs. (Fail-Secure Presence Mode is available on request. MOQ applies)  If permanent presence is not selected, then the detect time will be dependent on the change of inductance. The presence time on the limited presence setting will be approximately 1 hour for an inductance change of 3% ∆ L/L.   4.3.2  Pulse Mode    Link LK1 open  To set Channel 1 to Pulse mode switch ON switch 10  To set Channel 2 to Pulse mode switch ON switch 9    In the pulse mode the detector channels operate independently.  In the pulse mode the detector will give a pulse of 150 millisecond duration, when a vehicle enters the loop (Pulse on Detect) (a pulse of 250 millisecond is available on request. MOQ applies).
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 15 of 37               (Pulse on un-detect is available on request. MOQ applies)  4.3.3  AB Logic Presence Mode (Barrier Operation)    Internal link LK1 shorted from Pin 1 to Pin 2. In this mode switches 9 & 10 are ignored.  AB LOGIC Presence Mode is a direction logic mode, and is capable of determining direction of travel of a vehicle.  Two loops are laid in the direction of travel to provide the input for this mode.             If a vehicle enters Channel 1 Loop and then proceeds to Channel 2 Loop, Channel 1 relay contacts will close for the duration of that the vehicle is over Channel 2 Loop.  If a vehicle enters Channel 2 Loop and then proceeds to Channel 1 Loop, Channel 2 relay contacts will close for the duration of that the vehicle is over Channel 1 Loop.   Progress of a vehicle over the loops  Case 1: (AB LOGIC Presence Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Exits Loop 1, C - Vehicle Enters Loop2,  D - Vehicle Exits Loop 2,   Typically caused by loops  being too far apart or very  small vehicles
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 16 of 37 Case 2: (AB LOGIC Presence Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Exits Loop 1 D - Vehicle Exits Loop 2   This is the correct forward operation for Presence  AB Logic        Case 3: (AB LOGIC Presence Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Exits Loop 2 C - Vehicle Enters Loop1 D - Vehicle Exits Loop 1   Typically caused by loops  being too far apart or very  small vehicles        Case 4: (AB LOGIC Presence Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Exits Loop 2 D - Vehicle Exits Loop 1   This is the correct reverse operation for Presence  AB Logic
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 17 of 37 Case 5: (AB LOGIC Presence Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Starts to reverse D - Vehicle Exits Loop 2 E - Vehicle Exits Loop 1   This case should not  happen but it does  occasionally         Case 6: (AB LOGIC Presence Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Starts to reverse D - Vehicle Exits Loop 1 E - Vehicle Exits Loop 2   This case should not  happen but it does  occasionally      4.3.4  AB Logic Pulse Mode (Counting Logic)    Internal link LK1 shorted from Pin 2 to Pin 3. In this mode switches 9 & 10 are ignored.  AB LOGIC Pulse Mode is a direction logic mode, and is capable of determining direction of travel of a vehicle.  Two loops are laid in the direction of travel to provide the input for this mode.  This mode is used to activate equipment requiring vehicle direction inputs such as automatic fee collection equipment, vehicle counters, or warning devices in one-way systems.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 18 of 37   If a vehicle enters Channel 1 Loop and then proceeds to Channel 2 Loop, a 150 ms pulse will be issued on Channel 1 relay output as the vehicle leaves Channel 1 Loop.  If a vehicle now enters Channel 2 Loop and then proceeds to Channel 1 Loop, a 150 ms pulse will be issued on Channel 2 relay output as the vehicle leaves Channel 2 Loop.   Progress of a vehicle over the loops  Case 1: (AB LOGIC Pulse Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Exits Loop 1, C - Vehicle Enters Loop2,  D - Vehicle Exits Loop 2,   Typically caused by loops  being too far apart or very  small vehicles      Case 2: (AB LOGIC Pulse Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Exits Loop 1 D - Vehicle Exits Loop 2   This is the correct forward operation for Pulse  AB Logic      Case 3: (AB LOGIC Pulse Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Exits Loop 2 C - Vehicle Enters Loop1 D - Vehicle Exits Loop 1   Typically caused by loops  being too far apart or very  small vehicles
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 19 of 37  Case 4: (AB LOGIC Pulse Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Exits Loop 2 D - Vehicle Exits Loop 1   This is the correct reverse operation for Pulse AB Logic      Case 5: (AB LOGIC Pulse Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Starts to reverse D - Vehicle Exits Loop 2 E - Vehicle Exits Loop 1   Forward direction.  This case should not  happen but it does  occasionally    Case 6: (AB LOGIC Pulse Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Starts to reverse D - Vehicle Exits Loop 1 E - Vehicle Exits Loop 2   Reverse direction.  This case should not  happen but it does  occasionally   4.4  Response Times  The response time of the detector is the time taken from when a vehicle moves over the loop to when the detector gives an output on that channel.    The response times of the PD230 Enhanced Detectors has been adjusted to prevent false operation in electrically noisy environments, but retains adequate response to vehicles in parking and vehicle access control applications.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 20 of 37 5.  INSTALLATION GUIDE  Optimum functioning of the detector module is largely dependent on factors associated with the inductive sensor loop connected to it. These factors include choice of material, loop configuration and correct installation practice. A successful inductive loop vehicle detection system can be achieved by bearing the following constraints in mind, and strictly following the installation instructions. The detector must be installed in a convenient weatherproof location as close as possible to the loop.   5.1  Product Safety Requirements  • i) WARNING:  The unit must be EARTHED.  • ii) WARNING:  Disconnect the power before working on the unit.  • iii) WARNING:  On 120 Vac and 230 Vac models, a readily accessible disconnect  device must be incorporated into the mains wiring (as per EN60950-1:2005 Section 1.7.2.2).  • iv) WARNING:  All models the power supply to the unit MUST have short circuit  protection and over current protection installed at the power supply source (As  per  EN  60950-1:2005  section  1.7..2.3)  typically  this  will  be  a  5  Amp Magnetic Circuit Breaker for AC models and a fuse for DC models.  • v) WARNING:  This product must be installed in an enclosure.  • vi) WARNING:  No user serviceable parts inside.  ONLY  SERVICE  PERSONNEL  MAY  OPEN  THE  UNIT  TO  CHANGE INTERNAL SETTINGS  • vii) WARNING:  Only use CE approved 11 pin relay bases such as Nortech Part No.  CTR119090 or equivalent.   As  an  alternative  to  the  11  pin  relay  base,  Nortech  has  a  11  pin  wiring harness,  Nortech  Part  No. 302FT0041,  which  can only  be  used in  SELV voltage (less than 60 V dc or less than 42 V ac) applications.   5.2  Operational Constraints   5.2.1  Environmental Factors to Consider  Even though the PD230 Enhanced parking detectors are housed, the system integrator MUST ensure that the detector is installed in a housing/fire enclosure to protect it from the environment.  The PD230 Enhanced parking detectors are rated to operate at from – 40°C to +70°C but the rate of temperature change MUST not exceed 1°C per minute.  This system integrator MUST ensure that the housing used complies with this rate of temperature change requirement.  For installation Outdoors refer to Appendix B   For additional information on Environmental Factors refer to the section “Environmental Influences to Design Parameters” in the “Loops and Loop Installations” Manual, Nortech Document No. MKT05.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 21 of 37 5.2.2  Crosstalk  When two or more loop configurations are in close proximity, the magnetic fields of one loop can overlap and disturb the field of an other loop. This phenomena, is known as crosstalk, it can cause false detects and detector lock-up.  Should the loops be connected to the same dual channel detector crosstalk will not occur, due to the fact that sequential polling of the loops takes place, resulting in only one loop being energised at a given time.  Crosstalk between adjacent loops operating from different detector modules can be eliminated by:  1.  Careful choice of operating frequency. The closer together the two loops, the further apart the frequencies of operation must be.  2.  Separation between adjacent loops.  Where possible a minimum spacing of 2 metres between loops should be adhered to.  3.  Careful screening of feeder cables if they are routed together with other electrical cables. The screen must be earthed at the detector end only.  4.  Running feeder cables in their own slots, separated by at least 300 mm.  For additional information on Crosstalk refer to the section “Crosstalk Prevention” in the DU100 Diagnostic Unit User Manual Nortech Document No. 895UM0001  5.2.3  Reinforcing  The existence of reinforced steel below the road surface has the effect of reducing the inductance, and therefore the sensitivity, of the loop detection system. Hence, where reinforcing exists 2 turns should be added to the normal loop, as referred to in section 5.3.    The ideal minimum spacing between the loop and the cable and steel reinforcing is 150mm, although this is not always practically possible. The slot depth should be kept as shallow as possible, taking care that no part of the loop or the feeder remains exposed after the sealing compound has been applied.   5.3  Loop and Feeder Material Specification  Extensive studies have  been undertaken over the years by various agencies around the world in order to ascertain the optimum loop installation materials.  As an insulated conductor is a prerequisite, PVC covered cable has been used for many years as a first choice, but tests have shown, in fact, that this is unsuitable for long term installations. The PVC tends  to  become  porous  with  the  result  that  adjacent  loops  become  electrically  coupled  to  one another, with resultant crosstalk implications. Instability and susceptibility to electrical interference can also result.  The insulation must withstand wear and abrasion from the shifting streets, moisture, and attack by solvents and oils, as well as withstand the heat of high temperature sealants.  Silicone insulated cable has emerged as one of the preferred insulation materials. Other insulation materials are rubber, thermoplastic, synthetic polymer and cross linked polyethylene.  Stranded  loop  wire  is  preferred  over  solid  wire.  Because  of  its  mechanical  characteristics,  a stranded wire is more likely to survive bending and stretching than a solid.  A heavy gauge conductor is definitely desirous in order to maintain the loop Q-factor. The loop and feeder  should  preferably  constitute  a  single  length  of  insulated  multi-stranded  copper  conductor, with no joints and with the copper having a minimum cross section 1.5 mm2. The feeder is twisted to minimise the effect of electrical noise.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 22 of 37  Joints in the loop or feeder are not recommended. Where this is not possible, joints are to be soldered and terminated in a waterproof junction box. This is extremely important  for  reliable  detector  performance.  Other  forms  of  joins  such  as  those available in kits, where the joint is properly sealed against moisture, are also permitted.    5.4  Sensing Loop Geometry  NOTE:  1) The circumference of the loop must not exceed 30 m.  2) The area of the loop must not exceed 30 m2 and must not be less than 1 m2.   3) The loop must be constructed as detailed below.  Sensing loops should, unless site conditions prohibit, be rectangular in shape and should normally be installed with the longest sides at right angles to the direction of traffic movement. These sides should ideally be 1 metre apart.   Loops operating from the same detector module can share a common slot along one of the longer sides, if so required. This type of configuration could be applied in a direction logic application. The maximum separation permitted for this application is 1 metre, ensuring that a vehicle can straddle both loops simultaneously in the required direction of travel.    The only factor which governs maximum separation between loops in all other applications is the feeder length, with 100 metres being the maximum recommended length.  The length of the loop will be determined by the width of the roadway to be monitored. The loop should reach to within 300 mm of each edge of the roadway.  In general, loops having a circumference measurement in excess of 10 metres should be installed using two turns of wire, while loops of less than 10 metres in circumference should have three turns.  Loops having a circumference measurement less than 6 metres should have four turns.   It is good practice at time of installation to construct adjacent loops with alternate three and four turn windings.  For additional Information on loop geometry refer to the following documents: •  “INDUCTIVE LOOP VEHICLE DETECTION” - Nortech Doc. No. MKT0001. •  “TRAFFIC DETECTION” - Nortech Doc. No. MKT0002. •  “PARKING APPLICATIONS MANUAL” - Nortech Doc. No. MKT0003. •  “LOOPS and LOOP INSTALLATION” – Nortech Doc. No. MKT05   5.5  Loop Installation   All permanent loop installations should be installed in the roadway by cutting slots with a masonry cutting disc or similar device. A 45° crosscut shou ld be made across the loop corners to reduce the chance of damage that can be caused to the loop at right angle corners.  NOMINAL SLOT WIDTH:  4 mm  NOMINAL SLOT DEPTH:  30 mm to 50 mm  A slot must also be cut from the loop circumference at one corner of the loop to the roadway edge to accommodate the feeder.  A continuous loop and feeder is obtained by leaving a tail long enough to reach the detector before inserting the cable into the loop slot. Once the required number of turns of wire are wound into the slot around the loop circumference, the wire is routed again via the feeder slot to the roadway edge.  A similar length is allowed to reach the detector and these two free ends are twisted together to ensure they remain in close proximity to one another. (Minimum 20 turns per metre).  Maximum
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 23 of 37 recommended feeder length is 100 metres. It should be noted that the loop sensitivity decreases as the feeder length increases, so ideally the feeder cable should be kept as short as possible.  The loops are sealed using a “quick-set” black epoxy compound or hot bitumen mastic to blend with the roadway surface.     300 mm 300 mm+/- 2 m depending on road width1 m1 mMin Distance Apart - 2 m (Road width = 2 m)               - 3 m (Road width = 4 m)Max Distance Apart – No Limit  Figure 5.1  Adjacent loops connected to different detector modules    4 mm30 – 50 mm
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 24 of 37   Figure 5.2  Slot details
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 25 of 37 6.  CONFIGURATION   WARNING: 8.  The  connector  PIN assignments   vary from model to model.  Refer  to  the  label  on  the  side  of  the unit for connector PIN assignment.  NOTE 1:  The tables  below show  the PIN assignments for Nortech’s standard PD230  Enhanced detector models, on other models the pin assignments may change.  WARNING: 9.  The  wiring  harness  is  only  rated  for SELV  voltages  (less  than  60  V  dc  or less than 42 V ac).    If  the  relays  are  to  switch  higher voltages use CE LVD approved 11 pin sockets.   NOTE 2: All relay contact descriptions refer to the tuned and undetected state.   6.1  PD231 Enhanced Detector : English  11 – PIN CONNECTOR WIRING for: 302FT0014  302FT0041 WIRING HARNESS WIRE COLOUR  11 PIN Connector Pin No. Function Red  1  Live          Black  2  Neutral  120 V AC ± 10% 30 mA  60 Hz Blue  3  Channel 1 Loop Blue  4  Channel 1 Loop  Twist this  Pair Yellow  5  Channel 2 Loop Yellow  6  Channel 2 Loop  Twist this Pair Grey  7  Channel 2 N/O Relay Contact Grey  8  Channel 2 Relay Common Contact Green/Yellow  9  Earth White  10  Channel 1 N/O Relay Contact White  11  Channel 1 Relay Common Contact
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 26 of 37 6.2  PD232 Enhanced Detector: English  11 – PIN CONNECTOR WIRING for: 302FT0026  302FT0041 WIRING HARNESS WIRE COLOUR 11 PIN Connector Pin No. Function Red  1  Live Black  2  Neutral  230 V AC ± 10% 20 mA  50 Hz Blue  3  Channel 1 Loop Blue  4  Channel 1 Loop  Twist this pair Yellow  5  Channel 2 Loop Yellow  6  Channel 2 Loop  Twist this pair Grey  7  Channel 2 N/O Relay Contact Grey  8  Channel 2 Relay Common Contact Green/Yellow  9  Earth White  10  Channel 1 N/O Relay Contact White  11  Channel 1 Relay Common Contact     6.3  PD234 Enhanced Detector: English  11 – PIN CONNECTOR WIRING for: 302FT0008  302FT0041 WIRING HARNESS WIRE COLOUR Pin No.  Function Red  1 Black  2  12 – 24V AC/DC ± 10% 45 – 65 Hz  200 mA max Blue  3  Channel 1 Loop Blue  4  Channel 1 Loop  Twist this  pair Yellow  5  Channel 2 Loop Yellow  6  Channel 2 Loop  Twist this  pair Grey  7  Channel 2 N/O Relay Contact Grey  8  Channel 2 Relay Common Contact Green/Yellow  9  Earth White  10  Channel 1 N/O Relay Contact White  11  Channel 1 Relay Common Contact     WARNING: 10.  The wiring harness  wire colour  to PIN No. assignment only applies to the stated wiring harness Part No.    Other  wiring  harnesses  will  have different  wire  colour  to  PIN  No. assignments.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 27 of 37 7.  APPLICATIONS  The PD230 Enhanced dual channel detectors can be used in a variety of applications in the parking and door/gate environments.  •  To arm card readers and ticket dispensers •  As a barrier/gate/door closing detector •  As a barrier/gate/door opening detector ( Free exit ) •  To generate pulses for vehicle counting •  As a logic unit to determine the direction of traffic flow  Some of the features that make the PD230 Enhanced detectors ideal for these purposes have been described in the preceding paragraphs.  For more details on parking applications refer to ”Parking Applications Manual”, Document No. MKT0003.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 28 of 37 8.  CUSTOMER FAULT ANALYSIS  8.1  Fault Finding    FAULT  CAUSED BY  REMEDY  Red LED does not glow on power up  If the indicator is off then there is a fault on the power connection to the unit.   Check power feed to the unit.  After the initial tune period the Ch1 and/or Ch2 indicator is green. Turning off for half second periods.    Unit cannot tune to the loop due to faulty loop or feeder connection.  Loop may be too small or too large.  Faulty detector unit.  Check loop installation and connections.   Recut as per installation instructions.  Replace unit.   After tuning, the loop output LED’s flashes intermittently and the relay chatters     The loop is getting spurious detects due to:  a)  Crosstalk with       adjacent detector.  b)  Faulty loop or feeder       connection.     a)   Change frequency          setting.  b)  Check that the feeders are correctly connected and        adequately twisted.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 29 of 37 8.2  DU100 – Detector Diagnostic Unit  The DU100 Diagnostic unit is a hand-held test instrument that has been designed to operate with the PD230 Enhanced detector to provide installation/service personnel with positive verification of the correct operation of the vehicle detector and its installation.    The following parameters may be verified using this instrument:  1.  Detector type and version   2.  Loop status   Display of loop frequency and magnitude of current change of loop inductance  %∆L/L.  3.  Frequency    Readout of the actual loop operating frequency and the magnitude of the frequency drift since the last re-tune.  4.  Sensitivity    Displays the Minimum and Maximum changes of Inductance %∆L/L  that caused a detect since the last re-tune.  5.  Status    Displays the current status of the detector i.e. Undetect, Detect, Open circuit, Short circuit or Indeterminate.  6.  Time    The time in days and hours since the last re-tune and the reason for the last re-tune i.e. Reset: manual or power failure, Loop short circuit, Loop open circuit,  Indeterminate or an Inductance change of greater than 15 % ∆ L/L (typical).  This historical information is invaluable in providing information about intermittent faults.  7.  Crosstalk    Allows for the comparison of the operating frequencies of Detector loops in close proximity to each other. If the operating frequencies are to close the DU100 test will indicate a failure.   For further information refer to the Diagnostic Unit DU100 User Manual Document No. 895UM0001.  It is highly recommended that after installation of a detector (or if the loop has been changed in any way) that the DU100 Diagnostics Unit is used to verify the correct operation of the detector. A record of the readings should be kept so that if there is a problem in the future a comparison can be made to identify what has changed. The form in Appendix C could be used to record these readings.   8.2.1  Interpretation of the DU 100 readings  8.2.1.1  Frequency    For  the  PD230  Enhanced  Detector  the  Minimum  frequency  is  24  kHz  and  the  Maximum frequency is 78 kHz  If  a  20  µH  loop  is  connected  directly  (no  feeder  cable)  to  the  Detector  and  the  Frequency switches are set to “High Frequency” the typical frequency would be 78 kHz  If a  1000 µH loop is connected directly (no  feeder cable) to the Detector and the Frequency switches are set to “Low Frequency” the typical frequency would be 24 kHz  If the Frequency reading from the DU100 is close to the Minimum Frequency the inductance of the LOOP is too large – you need to remove turns from the loop  If the Frequency reading from the DU100 is close to the Maximum Frequency the inductance of the LOOP is too low and you need to add turns to the loop
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 30 of 37 If  the  detector  is  operating  close  to  either  limit  it  is  possible  that  either  the frequency  drift  caused  by  environmental  changes  or  the  shift  in  frequency caused by a large ∆L/L detect will cause the frequency to go outside the limits and cause a retune.   8.2.1.2   Frequency drift  The  PD230  Enhanced  Detector  can  handle  environmental  conditions  that  can  cause  the frequency to drift up to at a rate of approximating 1% ∆L/L per minute.  If  the  Drift  reading  approaches  this  value  the  detector  will  have  problems  tracking  the environmental change  If the drift is higher than say 0.5 % ∆ L/L per minute this will indicate a possible fault with the loop or feeder cable. Possibly the wire insulation has deteriorated and moisture is causing a short to earth or that wires of the loop are no longer encapsulated and are moving.  For  more  information  about  Frequency  drift  refer  to  the  “Theory  of  Application”  section  in Diagnostic Unit DU100 User Manual Document No. 895UM0001   8.2.1.3   Sensitivity  For a standard loop of 1.0 metres by 2.0 metres with 2 turns (circumference less than 10  meters) and a ten meter feeder cable the following table shows typical sensitivity values  for different vehicle types  VEHICLE TYPE  %∆∆∆∆ L/L Metal Supermarket Trolley   Bicycle  0.04 Motorbike  0.12 Articulated Truck  0.38 SUV (Four Wheel Drive)  0.40 5 Ton Tip Truck  0.45 Motor Car  > 1.00 Forklift  > 1.00  For more information about Sensitivity refer to the “Theory of Application” section in Diagnostic Unit DU100 User Manual Document No. 895UM0001  8.2.1.4   Time  This is a powerful tool in identifying problems with an installation. The time since the last retune of the detector will let you know when the event occurred and the reason will inform you of what caused the event   8.2.1.5   Crosstalk  For  information  about  resolving  crosstalk  refer  to  the  “Theory  of  Application”  section  in Diagnostic Unit DU100 User Manual Document No. 895UM0001
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 31 of 37 8.3  Functional Test  To test a detector, connect it to an inductive loop with a total inductance in the order of 300 microhenries. (This may be achieved in the workshop by winding (x) turns of wire on a non-metal former of diameter (y)).   x  = 19 turns 0.25 mm wire y  = 238 mm (9.4 inches)   Bring a small metal object approximately the size of a matchbox close to the loop coil. The following will happen on detection:  The OUTPUT LED will light up.  The PRESENCE output relay will operate  The PULSE relay will operate momentarily (approximately 150 ms duration)  To  check  the  sensitivity,  presence  time  etc.,  use  should  be  made  of  a  calibrated  tester,  which comprises of a calibrated loop similar to the one described above with a moveable vane, which can be moved over the loop at pre-determined heights.  This device together with the DU100 hand-held test instrument will allow comprehensive analysis of the operating characteristics of the detector.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 32 of 37 APPENDIX A - FCC ADVISORY STATEMENT   NOTE: This equipment has been tested and found to comply with the limits of Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.   Operation is subject to the following two conditions:   1  This device may not cause harmful interference, and  2  This device must accept any interference received, including interference that may cause undesired operation  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.   However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  The following booklets prepared by the Federal Communications Commission (FCC) may also prove helpful:  • How to Identify and Resolve Radio-TV Interference Problems (Stock No. 004-000-000345-4) • Interface Handbook (Stock No. 004-000-004505-7)  These booklets may be purchased from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.   WARNING: 10.  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 33 of 37 APPENDIX B – INSTALLATION OUTDOORS   Appendix B.1  IEC 60950-22:2005 – Outdoor cabinet  If the PD230 Enhanced Detector is to be installed outdoors it must be installed in a cabinet / housing that complies with the requirements of IEC 60950-22:2005 for a minimum of pollution degree 2.     Appendix B.2  IEC 60950-22:2005 - Northern Europe  To achieve outdoor operation down to -50 °C as requ ired by IEC 60950-22:2005 for Northern Europe (Finland, Norway and Sweden) a heater with a thermostat must be included in the cabinet that houses the PD230 Enhanced Detector.     Appendix B.3  IEC 60950-1:2005 – Overvoltage Category  If the unit is likely to be exposed to transient overvoltage greater that IEC 60950-1 Overvoltage Category II additional protection must be provided external to the unit on the supply lines.
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 34 of 37 APPENDIX C - REQUEST FOR TECHNICAL SUPPORT FORM   For Technical support please fill in the form below and send it to your supplier. It is recommended that at installation you complete this form as a record of the Installation. If there is a problem later on you can identify what has changed.  For locating faults in “Nortech Inductive Loop Vehicle Detector” installations it is highly recommended that you use the DU100 DIAGNOSTICS UNIT. Please refer to the DU100 user manual Doc. No. 895UM0001 for details of how to operate the DU100.   Contact Details:-  Your Name: ____________________________________________  Your company: ___________________________________________________________________  Telephone No. _______________________   Mobile/Cellphone No. _________________________  FAX No. ____________________________   Email Address _______________________________  Postal address: ____________________________________                            _____________________________________        _____________________________________   Product Model (i.e. PD234) ________________________  Product FT No.   302FT_____________  Product Serial Number: ___________________________   Site Name: _____________________________________ Detector No. (at the site): ______________  What are the settings of the switches on the front of the unit    ON or OFF      Switch  1   ___________  (FREQ  Frequency)      Switch  2   ___________  (FREQ  Frequency)      Switch  3   ___________  (SENS  Sensitivity Channel 2)      Switch  4   ___________  (SENS  Sensitivity Channel 2)      Switch  5   ___________  (SENS  Sensitivity Channel 1 )      Switch  6   ___________  (SENS  Sensitivity Channel 1)      Switch  7   ___________  (ASB    Automatic Sensitivity Boost)      Switch  8   ___________  (PRES  Presence Limited or Permanent)      Switch  9   ___________  (PULSE/PRES  Pulse or Presence Channel 2)      Switch  10  ___________  (PULSE/PRES  Pulse or Presence Channel 1)  What is the position of the internal link:(Pin 1 to 2  OR Pin 2 to 3 OR Open)? ____________________  (refer to section 3.3 above for functions of this link)  What application is this unit used in (short description)______________________________________    _________________________________________________________________________________  _________________________________________________________________________________
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 35 of 37  POWER SUPPLY DETAILS:   Nominal Voltage: _______ V     Minimum Voltage: _______ V    Maximum Voltage: ________ V  AC or DC ?    ______________   If AC then the Frequency _______  Hz  LOOP DETAILS  Channel 1            Channel 2  Size of loop:    ____ m by ____ m      Size of loop:    ____ m by ____ m  Shape of loop: _____________________    Shape of loop: _____________________  Number of Turns: _____         Number of Turns: _____  Size of wire used (mm2 or AWG) _____________  Size of wire used (mm2 or AWG) _____________  Type of wire insulation _____________________  Type of wire insulation _____________________  Thickness of insulation:_____________ mm    Thickness of insulation:____________ mm  How far below the surface is the loop: ________ mm  How far below the surface is the loop: _______ mm  Are there any metal objects below the loops such as concrete reinforcing, water pipes etc if yes please give details:  _____________________________________________________________________________   ____________________________________________________________________________  _____________________________________________________________________________  Are there any power cables below these loops (Yes/No) ____   If yes please give details:  _____________________________________________________________________________   _____________________________________________________________________________   _____________________________________________________________________________  Are there any other loops in the area (Yes/No) ____     If so how many?   ________  and   how close to these loops are they? ________ m  FEEDER CABLE DETAILS  Channel 1            Channel 2  Length of feeder cable ________ m      Length of feeder cable ________ m  Size of wire used (mm2 or AWG) _____________  Size of wire used (mm2 or AWG) _____________ (should be 1.5 mm2   or larger)  Type of wire insulation _____________________  Type of wire insulation _____________________  Thickness of insulation:_____________ mm    Thickness of insulation:____________ mm  Type of feeder cable used (screened, armoured, multicore, etc.)  __________________________________________________________________________
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 36 of 37  _________________________________________________________________________________  In the feeder cable how many twists per meter are there?____________ (should be more than 20 per metre)  Are there any other cables close to these feeder cables? (Yes/No) _____ If yes please give details:   _________________________________________________________________________________   ___________________________________________________________________  FEEDER CABLE and LOOP DETAILS  Channel 1            Channel 2  Is the loop and feeder cable one continuous     Is the loop and feeder cable one continuous piece of wire or is there a joint between the     piece of wire or is there a joint between the loops and the feeder?  (Yes/No) _______      loops and the feeder?  (Yes/No) _______  Please give details:__________________________________________________________________  _________________________________________________________________________________  With the detector disconnected, measure the following:-  Channel 1            Channel 2  AC voltage between the two wires of the     AC voltage between the two wires of the feeder cable __________ V        feeder cable __________ V   AC voltage between one of the feeder cable    AC voltage between one of the feeder cable  wires and earth __________ V        wires and earth __________ V   DC resistance of Feeder plus Loop: _______  ohms  DC resistance of Feeder plus Loop: _______ ohms   Inductance of Feeder plus Loop: ________ µH    Inductance of Feeder plus Loop: ______ µH   Frequency of measurement? ______ KHz      Frequency of measurement? ______ KHz   Loop and feeder resistance to earth      Loop and feeder resistance to earth (with detector unplugged) using a       (with detector unplugged) using a   500V Megger: _________ Mega Ohms      500V Megger: _________ Mega Ohms (should be greater than 10 Mega Ohms)      (should be greater than 10 Mega Ohms)
 302UM0017 Rev 01  PD230 Enhanced Detector User Manual   Page 37 of 37 READINGS FROM DU100 DIAGNOSTICS UNIT  On arrival at site Time since last retune: ___________ days    _____________ hours   Reason for Retune (Reset: manual or power failure, Short circuit, Open circuit, Indeterminate, Inductance change of greater than 15 % ∆ L/L (typical):        _______________________________________________  Channel 1            Channel 2  Frequency ______________ kHz      Frequency ______________ kHz  Loop Frequency Drift __________ %      Loop Frequency Drift __________ %  Sensitivity  Min: ___________ %∆L/L      Sensitivity  Min: ___________ %∆L/L  Sensitivity Max: ___________  %∆L/L      Sensitivity Max: ___________  %∆L/L  Channel Status:____________________________  Channel Status:____________________________  (Undetect, Detect, Open circuit, Short circuit or Indeterminate)  (Undetect, Detect, Open circuit, Short circuit or Indeterminate)  Inductance Change for each vehicle type (Use the maximum sensitivity reading from the DU100 and reset the detector between each reading):  Vehicle Type  Channel 1 Inductance Change  Channel 2 Inductance Change Bicycle  %∆L/L %∆L/L Motorbike  %∆L/L %∆L/L Car  %∆L/L %∆L/L SUV  %∆L/L %∆L/L Articulated truck  %∆L/L %∆L/L 5 Ton Tip Truck  %∆L/L %∆L/L Forklift  %∆L/L %∆L/L Other type (Please specify)   %∆L/L  %∆L/L  Channel 1            Channel 2  Crosstalk (Pass / Fail): _______________     Crosstalk (Pass / Fail): _______________  (If fail actual frequencies of the two problem detector loops)    (If fail actual frequencies of the two problem detector loops)  Frequency 1:___________kHz        Frequency 1:___________kHz  Frequency 2:______________kHz      Frequency 2:______________kHz  Comments: _______________________________________________________________________  ______________________________________________________________________________________  ______________________________________________________________________________________
  Nortech International (Pty) Ltd PO Box 4099  32A Wiganthorpe Road Willowton Hub  Pietermaritzburg Pietermaritzburg  3201 South Africa 3200 South Africa  Reg. No. 98/1095  Tel: (033) 345 3456   Int. Tel: +27 33 345 3456 Fax: (033) 394 6449  Int Fax: +27 33 394 6449 E-mail: mkt@nortech.co.za  URL: www.nortech.co.za                                                TD236 Enhanced Vehicle Detector USER MANUAL        NORTECH INTERNATIONAL (PTY) LTD All rights reserved.  Copyright  © 2009 Document No.: 306UM0002_01a Date of issue: August 2010  This document is for information only and unless otherwise indicated it is not to form part of any contract.  In accordance with the manufacturer’s policy of continually updating and improving design, specifications contained herein are subject to alterations without notice.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 2 of 35  Table of Contents  1. INTRODUCTION .............................................................................................................................5 2. TECHNICAL DATA .........................................................................................................................6 2.1 Functional Data..........................................................................................................................6 2.2 Electrical Data............................................................................................................................6 2.3 Environmental Data....................................................................................................................7 2.4 Mechanical Data ........................................................................................................................8 2.5 Approvals ...................................................................................................................................8 3. OPERATING INSTRUCTIONS .......................................................................................................9 3.1 Hardware Set-up........................................................................................................................9 3.2 Switch Setting Selections...........................................................................................................9 3.2.1 Frequency Switch..............................................................................................................9 3.2.2 Sensitivity ..........................................................................................................................9 3.2.3 Presence Time ................................................................................................................10 3.2.4 Pulse / Presence .............................................................................................................10 3.2.5 Reset Switch ...................................................................................................................10 3.3 Internal Link Selection..............................................................................................................11 3.4 Front Panel Indicators..............................................................................................................11 4. PRINCIPLE OF OPERATION .......................................................................................................12 4.1 Detector Tuning........................................................................................................................12 4.2 Detector Sensitivity ..................................................................................................................12 4.3 Modes of Operation .................................................................................................................13 4.3.1 Presence Mode ...............................................................................................................13 4.3.2 Pulse Mode......................................................................................................................13 4.3.3 AB Logic Presence Mode (Barrier Operation) ................................................................14 4.3.4 AB Logic Pulse Mode (Counting Logic) ..........................................................................16 4.4 Response Times ......................................................................................................................18 5. INSTALLATION GUIDE................................................................................................................19 5.1 Product Safety Requirements..................................................................................................19 5.2 Operational Constraints ...........................................................................................................19 5.2.1 Environmental Factors to Consider.................................................................................19 5.2.2 Crosstalk..........................................................................................................................20 5.2.3 Reinforcing ......................................................................................................................20 5.3 Loop and Feeder Material Specification ..................................................................................20 5.4 Sensing Loop Geometry ..........................................................................................................21 5.5 Loop Installation.......................................................................................................................21 6. CONFIGURATION.........................................................................................................................23 6.1 TD234 Enhanced Detector: English ........................................................................................23 6.2 TD236 Enhanced Detector: English ........................................................................................24 6.3 TD236 Enhanced Detector: .....................................................................................................24 6.4 TD236 Enhanced Detector: .....................................................................................................24 7. APPLICATIONS ............................................................................................................................25 8. CUSTOMER FAULT ANALYSIS ..................................................................................................26 8.1 Fault Finding ............................................................................................................................26 8.2 DU100 – Detector Diagnostic Unit...........................................................................................27 8.2.1 Interpretation of the DU 100 readings.............................................................................27 8.2.1.1  Frequency.........................................................................................................................27 8.2.1.2   Frequency drift.................................................................................................................28 8.2.1.3   Sensitivity.........................................................................................................................28 8.2.1.4   Time .................................................................................................................................28 8.2.1.5   Crosstalk..........................................................................................................................28 8.3 Functional Test.........................................................................................................................29 APPENDIX A - FCC ADVISORY STATEMENT ..................................................................................30 APPENDIX B – INSTALLATION OUTDOORS....................................................................................31 Appendix B.1 IEC 60950-22:2005 – Outdoor cabinet ..............................................................31
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 3 of 35     Appendix B.2 IEC 60950-22:2005 - Northern Europe ..............................................................31 Appendix B.3 IEC 60950-1:2005 – Overvoltage Category.......................................................31 APPENDIX C - REQUEST FOR TECHNICAL SUPPORT FORM.......................................................32
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 4 of 35   WARNING: 1.  THIS UNIT MUST BE  EARTHED !    WARNING: 2.  DISCONNECT POWER BEFORE  WORKING ON THIS UNIT !    WARNING: 3.  INSTALLATION AND OPERATION    BY SERVICE PERSONNEL ONLY !    WARNING: 4.  NO USER SERVICEABLE PARTS INSIDE.  ONLY SERVICE PERSONNEL MAY OPEN THE UNIT TO CHANGE INTERNAL SETTINGS!    WARNING: 5.  USA  FCC Advisory Statement – Refer to Appendix A at the end of this document.   WARNING: 6. Europe  Disposing of the product.  This electronic product is subject to the EU Directive 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE). As such, this product must not be disposed of at a local municipal waste collection point. Please refer to local regulations for directions on how to dispose of this product in an environmental friendly manner.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 5 of 35  1.  INTRODUCTION  The “TD236 Enhanced Two Channel Inductive Loop Vehicle Detector” is a dual channel microprocessor based detector designed specifically for traffic control applications. The TD236 Enhanced detector has been designed using the latest technology in order to meet the requirements of a vast number of traffic applications in terms of operating conditions. A number of internal functional options are available to the user.  The primary function of the detector is to detect vehicle presence by means of an inductance change caused by the vehicle passing over a wire loop buried under the road surface.                              The detector has been designed for ease of installation and convenience. The various modes are selected by changing the position of switches on the front of the unit.  The detector oscillator is multiplexed to eliminate any possibility of crosstalk between the loops connected to the detector.  The switches allow for different loop frequency settings, sensitivity settings and mode settings.  The unit has a number of internally selectable options for configuration of the relay outputs.  The TD236 Enhanced detector provides visual outputs (LED) on the front of the enclosure and relay change-over contacts at the 11 pin connector at the rear of the enclosure. The power LED indicates that the unit has been powered. The channel status LED’s below indicate that a vehicle is present over the loop and when there is a fault on the loop. The Presence relays are normally fail-safe and will close on a vehicle detect, loop failure or in the event of a power failure.  For additional information refer to the following documents:  Data Sheet - TD236 Enhanced 2 Ch Vehicle Detector     Document No. 306DS0001 Installation Leaflet            Document No. 879LF0006 Diagnostic Unit DU100 User Manual         Document No. 895UM0001  2/4 Ch Vehicle Detector Installation Guide      Document No. 879LF0006
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 6 of 35  2.  TECHNICAL DATA   2.1  Functional Data  Tuning        Fully automatic  Self-tuning range    20 to 1000 µH  Sensitivity      Four step switch selectable:          High     0.02% ∆ L/L          Medium-High  0.05% ∆ L/L          Medium-Low  0.10% ∆ L/L          Low    0.50% ∆ L/L  Frequency      Four step selectable:          Frequency dependent on loop size  Modes        Output relays may operate in the Presence ( fail-safe ),          or Direction logic modes  Presence Time      Switch selectable:          1 Second          4 Minutes         40 Minutes          No fixed time-out (dependant on inductance change) Approx.  1 hour for 3 % ∆ L/L  Response Times    75 milliseconds  Drift Compensation Rate   Approx. 1% ∆ L/L per minute  Visual Indication     1 x Power LED - Red          2 x Channel Status LED - Green  Relay Outputs      2 x Relays, User Configurable as Presence or Pulse outputs,  Normally Open (N/O) contacts (Opto-Isolated Outputs are available on request. MOQ applies)  Reset        Reset by push button on front of enclosure  Surge Protection    Loop isolation transformer, gas discharge tubes,   and Zener diode clamping on loop input    2.2  Electrical Data   Power requirements    230V AC ± 10% 48 to 62Hz            230V models: 1.5 VA Maximum at 230V  12V - 10% to 24V + 10% DC/AC 48 to 62Hz           12-24 V  models: 1 VA Maximum at 12V
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 7 of 35  Relay Contact Rating    2 x Relays rated - 5A @ 230 VAC For ambient temperatures above 60 °C De-rate the relay maximum current as per graph below                  Opto-Isolated Output rating  33 V 50 mA  Note - Opto-Isolated Outputs are available on request. MOQ applies     2.3  Environmental Data  Storage Temperature    -40°C to +85°C  Operating Temperature    -40°C to +70°C  Humidity       Up to 95% relative humidity without condensation  Circuit Protection    Conformal coating over the PCB and all components  IP Rating      IP 30. - This product MUST be installed in an enclosure
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 8 of 35  2.4  Mechanical Data  Housing material   ABS blend  Mounting Position    Shelf or DIN rail mounting  Connections      11-pin submagnal type ( JEDEC No. B11– 88 )  Size of Housing     78mm ( High ) x 41mm ( Wide ) x 80mm ( Deep )                          2.5  Approvals   C.E. Regulations  EN 301 489    Equipment Type: III               Class of Equipment: 2        EN 50293    Performance Criteria B   Safety:      IEC / EN 60950-1    80 mm75.9 mm77.7 mm40.6 mm
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 9 of 35  3.  OPERATING INSTRUCTIONS  3.1  Hardware Set-up  The TD236 Enhanced dual channel traffic detector is designed to be shelf or DIN rail mounted with the controls and visual indicators at the front and wiring at the rear of the enclosure.  The power, loop and relay outputs are all connected to the single 11-pin plug, which is mounted at the rear of the enclosure.  3.2  Switch Setting Selections   3.2.1  Frequency Switch   Where more than one detector is used at the same site, the detectors must be set-up to ensure that there is no CROSSTALK (interference) between adjacent loops connected to different detectors.   For more information about crosstalk refer to section 5.2.2.  The frequency switches are the lower two switches, numbered 1 and 2. There are four frequency selections and are set as follows:        The frequency switches allow the operating frequencies of the detector to be shifted higher or lower depending on the setting of the two switches.  The operating frequency of the detector channel is determined by: Inductance of the loop and feeder cable Detector frequency switch settings  The operating frequency of the detector channel increases as the loop inductance decreases and vice versa.   The inductance of the loop and feeder cable is determined by:  Size of the loop Number of turns in the loop Length of feeder cable  As a general rule, the detector connected to the inductive loop with the greatest inductance should be set to operate at the lowest frequency.  When the frequency switch setting is altered, the operating frequency of both detector channels will shift. Because the unit has a common oscillator and the multiplexer connects the loops alternatively to this oscillator.  3.2.2  Sensitivity   The sensitivity of the detector allows the detector to be selective as to the magnitude of the change of inductance necessary to produce an output. There are four sensitivity selections and are set as follows: -  S1  S2  Frequency Setting Off  Off  High frequency Off  On  Medium-High frequency On  Off  Medium-Low frequency On  On  Low frequency
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 10 of 35  Channel1  Channel 2  S6  S5  S4  S3   Off   Off  Off  Off  High On  Off  On  Off  Medium-High Off  On  Off  On  Medium-Low On  On  On  On  Low  3.2.3  Presence Time   The presence time is a mode, which allows the detector to have a presence time of no longer than the time set by the switch settings. There are four presence time selections available and can be selected by using switches numbered 7 and 8 on the front of the enclosure as follows: -  S8  S7  Off  Off  ∞ no fixed time On  Off  40 minutes Off  On  4 minutes On  On  1 Second  The presence time as shown above, may be altered according to the requirements.  The 1 second presence time setting will give a pulse on detection of a vehicle with a duration of 1 second. The detector will immediately re-adjust to the normal operating point and will give another detect  in  the  event  of  a  further  change  in  the  loop  inductance.  The  detector  may  be  used  as  a passage detector in this mode.  The 4 minute and 40 minute presence time settings work in the same way as the 1 second setting, however the detector will now give outputs of 4 minutes or 40 minutes. If the vehicle which caused the inductance change moves off the loop within the selected time period, then the detector will go out of detect and the presence time will be reset to zero for the next detect cycle. The detector may undetect before the expired time period if the change in inductance for the vehicle is small   The  “no  fixed  time-out”  setting  does  not  have  a  fixed  time  period  and  the  presence  time  is dependant on the magnitude of the inductance change caused by the vehicle over the loop.  On times longer than 1 second there will be a “paralysis time” of approximately 4 seconds between actuations.  3.2.4  Pulse / Presence   The channel’s relay may be set to either Pulse Mode or Presence Mode with switches No. 9 & No. 10 as shown in the table below: -  Channel1  Channel 2  S10  S9   Off  Off  Presence  On  On  Pulse       3.2.5  Reset Switch   The  detector  automatically  tunes  to  the  inductive  loops  connected  to  it  when  power  is  applied, whether on initial installation or after any interruption in the power supply. Should it be necessary to retune the detector, as may be required after the changing of any switch selections or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle. Tuning should take approximately 5 seconds
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 11 of 35  3.3  Internal Link Selection  WARNING - ONLY SERVICE PERSONNEL MAY OPEN THE UNIT TO CHANGE INTERNAL SETTINGS!  There is one 3 way link located inside the TD236 Enhanced detector housing, which is used to alter the mode of operation of the detector. The link has been placed inside the unit to avoid incorrect operation due to selection by an unauthorised operator.                        For a description of the AB Logic mode refer to section 4.3 “Modes of Operation” below   For  the  TD236  Enhanced  traffic  detector,  the  default  setting  for  both  channel  output  relays  is presence mode (Front panel switches 9 & 10 OFF) with no AB logic (i.e. no jumper on LK1).  It is recommended that for traffic applications, both channel output relays remain in presence mode (i.e. front panel switches 9 & 10 ON). Should the AB-logic mode be required, it is recommended that presence AB logic mode is selected (i.e. a jumper on link LK1 from pin 1 to pin 2 as shown in the above diagram).    3.4  Front Panel Indicators  While the detector is tuning, the Channel LED will indicate the “mode” status of the detector.  i) Any Channel output operating in the presence or pulse modes will come on and extinguish when the system is tuned.  ii) When the AB Logic mode is selected, the Channel LED’s will alternatively flash slow and extinguish when the system is tuned.  If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate and the LED will continue to show the historical fault. The detector must be reset or power removed to clear the historical fault information.  The channel LED will also glow whenever a vehicle is detected passing over the inductive loop.  The Power LED at the top of the unit will remain on to indicate that the unit is powered. This LED is also used as the link to the diagnostic unit ( DU100 ).
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 12 of 35  4.  PRINCIPLE OF OPERATION  The inductive loop vehicle detector senses the presence of a vehicle over an area defined by a loop of two or more turns of wire laid under the road or pavement surface. This loop of wire is connected to the detector by a pair of wires called a loop feeder.    A vehicle passing over a sensing loop causes a small reduction in the inductance of the loop, which is sensed by the detector. The sensitivity of detection is adjustable to accommodate a wide range of vehicle types as well as different loop and feeder combinations.    Upon detection of a vehicle passing over the loop the detector operates its output relays which may be used to indicate controls associated with the installation.   4.1  Detector Tuning  Tuning of the detector is fully automatic. The detector will re-tune if any of the following events occur:-  - When power is applied to the detector. - A detector reset is initiated via the reset button.  - A detect of greater than 15% ∆ L/L occurs.  The detector will automatically tune each channel to its connected loop. The detector will tune to any loop in the inductance range of 20 to 1000 micro-henries.    This wide range ensures that all loop sizes and feeder combinations will be accommodated in the tuning range of the detector.    Once tuned, any slow environmental change in loop inductance is fed to a compensating circuit within the detector, which keeps the detector correctly tuned.   4.2  Detector Sensitivity  Sensitivity of the detection system is dependent on factors such as loop size, number of turns in the loop, feeder length and the presence of metal reinforcing beneath the loop.   The nature of the application determines the required sensitivity level, which may be adjusted by means of the sensitivity switches on the front panel.     Sensitivity levels on the TD236 Enhanced detectors have been carefully optimised for traffic control applications.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 13 of 35  4.3  Modes of Operation  The TD236 Enhanced Detector may be configured for any one of the following modes:  Presence Mode Pulse Mode AB Logic Presence Mode (Barrier Operation) AB Logic Pulse Mode (Counting Logic)  4.3.1  Presence Mode    Link LK1 open  To set Channel 1 to Presence mode switch OFF switch 10  To set Channel 2 to Presence mode switch OFF switch 9    In the presence mode the detector channels operate independently  In the presence mode the detector will give a continuous output during the presence of a vehicle over the inductive loop, providing that the preset time has not expired. Upon expiry, the detector will undetect and tune out the vehicle over the loop. Refer to section 3.2.3 above for presence time settings.  If the no fixed time-out presence time setting is selected, then the detect time will be dependent on the change of inductance.                The presence outputs are known as fail-safe outputs. This implies that in the event of a power failure or loop failure the detector will give detect outputs. (Fail-Secure Presence Mode is available on request. MOQ applies)    4.3.2  Pulse Mode    Link LK1 open  To set Channel 1 to Pulse mode switch ON switch 10  To set Channel 2 to Pulse mode switch ON switch 9    In the pulse mode the detector channels operate independently.  In the pulse mode the detector will give a pulse of 150 millisecond duration, when a vehicle enters the loop (Pulse on Detect) (a pulse of 250 millisecond is available on request. MOQ applies).
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 14 of 35                (Pulse on un-detect is available on request. MOQ applies)    4.3.3  AB Logic Presence Mode (Barrier Operation)    Internal link LK1 shorted from Pin 1 to Pin 2. In this mode switches 9 & 10 are ignored.  AB LOGIC Presence Mode is a direction logic mode, and is capable of determining direction of travel of a vehicle.  Two loops are laid in the direction of travel to provide the input for this mode.             If a vehicle enters Channel 1 Loop and then proceeds to Channel 2 Loop, Channel 1 relay contacts will close for the duration of that the vehicle is over Channel 2 Loop.  If a vehicle enters Channel 2 Loop and then proceeds to Channel 1 Loop, Channel 2 relay contacts will close for the duration of that the vehicle is over Channel 1 Loop.   Progress of a vehicle over the loops  Case 1: (AB LOGIC Presence Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Exits Loop 1, C - Vehicle Enters Loop2,  D - Vehicle Exits Loop 2,   Typically caused by loops  being too far apart or very  small vehicles
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 15 of 35  Case 2: (AB LOGIC Presence Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Exits Loop 1 D - Vehicle Exits Loop 2   This is the correct forward operation for Presence  AB Logic        Case 3: (AB LOGIC Presence Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Exits Loop 2 C - Vehicle Enters Loop1 D - Vehicle Exits Loop 1   Typically caused by loops  being too far apart or very  small vehicles        Case 4: (AB LOGIC Presence Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Exits Loop 2 D - Vehicle Exits Loop 1   This is the correct reverse operation for Presence  AB Logic
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 16 of 35  Case 5: (AB LOGIC Presence Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Starts to reverse D - Vehicle Exits Loop 2 E - Vehicle Exits Loop 1   This case should not  happen but it does  occasionally        Case 6: (AB LOGIC Presence Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Starts to reverse D - Vehicle Exits Loop 1 E - Vehicle Exits Loop 2   This case should not  happen but it does  occasionally     4.3.4  AB Logic Pulse Mode (Counting Logic)    Internal link LK1 shorted from Pin 2 to Pin 3. In this mode switches 9 & 10 are ignored.  AB LOGIC Pulse Mode is a direction logic mode, and is capable of determining direction of travel of a vehicle.  Two loops are laid in the direction of travel to provide the input for this mode.  This mode is used to activate equipment requiring vehicle direction inputs such as automatic fee collection equipment, vehicle counters, or warning devices in one-way systems.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 17 of 35  If a vehicle enters Channel 1 Loop and then proceeds to Channel 2 Loop, a 150 ms pulse will be issued on Channel 1 relay output as the vehicle leaves Channel 1 Loop.  If a vehicle now enters Channel 2 Loop and then proceeds to Channel 1 Loop, a 150 ms pulse will be issued on Channel 2 relay output as the vehicle leaves Channel 2 Loop.   Progress of a vehicle over the loops  Case 1: (AB LOGIC Pulse Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Exits Loop 1, C - Vehicle Enters Loop2,  D - Vehicle Exits Loop 2,   Typically caused by loops  being too far apart or very  small vehicles      Case 2: (AB LOGIC Pulse Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Exits Loop 1 D - Vehicle Exits Loop 2   This is the correct forward operation for Pulse AB Logic      Case 3: (AB LOGIC Pulse Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Exits Loop 2 C - Vehicle Enters Loop1 D - Vehicle Exits Loop 1   Typically caused by loops  being too far apart or very  small vehicles
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 18 of 35   Case 4: (AB LOGIC Pulse Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Exits Loop 2 D - Vehicle Exits Loop 1   This is the correct reverse operation for Pulse AB Logic       Case 5: (AB LOGIC Pulse Mode)  Forward direction  A - Vehicle Enters Loop1 B - Vehicle Enters Loop2 C - Vehicle Starts to reverse D - Vehicle Exits Loop 2 E - Vehicle Exits Loop 1   This case should not  happen but it does  occasionally     Case 6: (AB LOGIC Pulse Mode)  Reverse direction  A - Vehicle Enters Loop2 B - Vehicle Enters Loop1 C - Vehicle Starts to reverse D - Vehicle Exits Loop 1 E - Vehicle Exits Loop 2   This case should not  happen but it does  occasionally   4.4  Response Times  The response time of the detector is the time taken from when a vehicle moves over the loop to when the detector gives an output on that channel.    The response times of the TD236 Enhanced detectors have been adjusted to provide adequate response to vehicles in traffic control applications.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 19 of 35  5.  INSTALLATION GUIDE  Optimum functioning of the detector module is largely dependent on factors associated with the inductive sensor loop connected to it. These factors include choice of material, loop configuration and correct installation practice. A successful inductive loop vehicle detection system can be achieved by bearing the following constraints in mind, and strictly following the installation instructions. The detector must be installed in a convenient weatherproof location as close as possible to the loop.   5.1  Product Safety Requirements  • i) WARNING:  The unit must be EARTHED.  • ii) WARNING:  Disconnect the power before working on the unit.  • iii) WARNING:  On 120 Vac and 230 Vac models, a readily accessible disconnect  device must be incorporated into the mains wiring (as per EN60950-1:2005 Section 1.7.2.2).  • iv) WARNING:  All models the power supply to the unit MUST have short circuit  protection and over current protection installed at the power supply source (As  per  EN  60950-1:2005  section  1.7.2.3)  typically  this  will  be  a  5  Amp Magnetic Circuit Breaker for AC models and a fuse for DC models.  • v) WARNING:  This product must be installed in an enclosure as the IP rating of the  detector is IP30.  • vi) WARNING:  No user serviceable parts inside.  ONLY  SERVICE  PERSONNEL  MAY  OPEN  THE  UNIT  TO  CHANGE INTERNAL SETTINGS  • vii) WARNING:  Only use CE approved 11 pin relay bases such as Nortech Part No.  CTR119090 or equivalent.   As  an  alternative  to  the  11  pin  relay  base,  Nortech  has  a  11  pin  wiring harness,  Nortech  Part  No. 302FT0041,  which  can only  be  used in  SELV voltage (less than 60 V dc or less than 42 V ac) applications.   5.2  Operational Constraints   5.2.1  Environmental Factors to Consider  Even though the TD236 Enhanced traffic detectors are housed, the system integrator MUST ensure that the detector is installed in a housing/fire enclosure to protect it from the environment.  The TD236 Enhanced traffic detectors are rated to operate from – 40°C to +70°C but the rate of temperature change MUST not exceed 1°C per minute.  The system integrator MUST ensure that the housing used complies with this rate of temperature change requirement.  For installation Outdoors refer to Appendix B   For additional information on Environmental Factors refer to the section “Environmental Influences to Design Parameters” in the “Loops and Loop Installations” Manual, Nortech Document No. MKT05.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 20 of 35  5.2.2  Crosstalk  When two or more loop configurations are in close proximity, the magnetic fields of one loop can overlap and disturb the field of another loop. This phenomena, is known as crosstalk, it can cause false detects and detector lock-up.    Should the loops be connected to the same dual channel detector crosstalk will not occur, due to the fact that sequential polling of the loops takes place, resulting in only one loop being energised at a given time.  Crosstalk between adjacent loops operating from different detector modules can be eliminated by:  1.  Careful choice of operating frequency. The closer together the two loops, the further apart the frequencies of operation must be.  2.  Separation between adjacent loops.  Where possible a minimum spacing of 2 metres between loops should be adhered to.  3.  Careful screening of feeder cables if they are routed together with other electrical cables. The screen must be earthed at the detector end only.  4.  Running feeder cables in their own slots, separated by at least 300 mm.  For additional information on Crosstalk refer to the section “Crosstalk Prevention” in the DU100 Diagnostic Unit User Manual Nortech Document No. 895UM0001  5.2.3  Reinforcing  The existence of reinforced steel below the road surface has the effect of reducing the inductance, and therefore the sensitivity, of the loop detection system. Hence, where reinforcing exists 2 turns should be added to the normal loop, as referred to in section 5.3.    The ideal minimum spacing between the loop and the cable and steel reinforcing is 150 mm, although this is not always practically possible. The slot depth should be kept as shallow as possible, taking care that no part of the loop or the feeder remains exposed after the sealing compound has been applied.   5.3  Loop and Feeder Material Specification  Extensive studies have  been undertaken over the years by various agencies around the world in order to ascertain the optimum loop installation materials.  As an insulated conductor is a prerequisite, PVC covered cable has been used for many years as a first choice, but tests have shown, in fact, that this is unsuitable for long term installations. The PVC tends  to  become  porous  with  the  result  that  adjacent  loops  become  electrically  coupled  to  one another, with resultant crosstalk implications. Instability and susceptibility to electrical interference can also result.  The insulation must withstand wear and abrasion from the shifting streets, moisture, and attack by solvents and oils, as well as withstand the heat of high temperature sealants.  Silicone insulated cable has emerged as one of the preferred insulation materials. Other insulation materials are rubber, thermoplastic, synthetic polymer and cross linked polyethylene.  Stranded  loop  wire  is  preferred  over  solid  wire.  Because  of  its  mechanical  characteristics,  a stranded wire is more likely to survive bending and stretching than a solid.  A heavy gauge conductor is definitely desirous in order to maintain the loop Q-factor. The loop and feeder  should  preferably  constitute  a  single  length  of  insulated  multi-stranded  copper  conductor, with no joints and with the copper having a minimum cross section 1.5 mm2. The feeder is twisted to minimise the effect of electrical noise.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 21 of 35   Joints in the loop or feeder are not recommended. Where this is not possible, joints are to be soldered and terminated in a waterproof junction box. This is extremely important  for  reliable  detector  performance.  Other  forms  of  joins  such  as  those  available  in kits, where the joint is properly sealed against moisture, are also permitted.   5.4  Sensing Loop Geometry  NOTE:  1) The circumference of the loop must not exceed 30 m.  2) The area of the loop must not exceed 30 m2 and must not be less than 1 m2.   3) The loop must be constructed as detailed below.  Sensing loops should, unless site conditions prohibit, be rectangular in shape and should normally be installed with the longest sides at right angles to the direction of traffic movement. These sides should ideally be 1 metre apart.   Loops operating from the same detector module can share a common slot along one of the longer sides, if so required. This type of configuration could be applied in a direction logic application. The maximum separation permitted for this application is 1 metre, ensuring that a vehicle can straddle both loops simultaneously in the required direction of travel.    The only factor which governs maximum separation between loops in all other applications is the feeder length, with 100 metres being the maximum recommended length.  The length of the loop will be determined by the width of the roadway to be monitored. The loop should reach to within 300 mm of each edge of the roadway.  In general, loops having a circumference measurement in excess of 10 metres should be installed using two turns of wire, while loops of less than 10 metres in circumference should have three turns or more.  Loops having a circumference measurement less than 7 metres should have four turns.   It is good practice at time of installation to construct adjacent loops with alternate three and four turn windings.  For additional Information on loop geometry refer to the following documents: •  “INDUCTIVE LOOP VEHICLE DETECTION” - Nortech Doc. No. MKT01. •  “TRAFFIC DETECTION” - Nortech Doc. No. MKT02. •  “PARKING APPLICATIONS MANUAL” - Nortech Doc. No. MKT03. •  “LOOPS and LOOP INSTALLATION” – Nortech Doc. No. MKT05   5.5  Loop Installation   All permanent loop installations should be installed in the roadway by cutting slots with a masonry cutting disc or similar device. A 45° crosscut shou ld be made across the loop corners to reduce the chance of damage that can be caused to the loop at right angle corners.  NOMINAL SLOT WIDTH:  4 mm  NOMINAL SLOT DEPTH:  30 mm to 50 mm  A slot must also be cut from the loop circumference at one corner of the loop to the roadway edge to accommodate the feeder.  A continuous loop and feeder is obtained by leaving a tail long enough to reach the detector before inserting the cable into the loop slot. Once the required number of turns of wire are wound into the slot around the loop circumference, the wire is routed again via the feeder slot to the roadway edge.  A similar length is allowed to reach the detector and these two free ends are twisted together to ensure they remain in close proximity to one another. (Minimum 20 turns per metre).  Maximum recommended feeder length is 100 metres. It should be noted that the loop sensitivity decreases as the feeder length increases, so ideally the feeder cable should be kept as short as possible.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 22 of 35   The loops are sealed using a “quick-set” black epoxy compound or hot bitumen mastic to blend with the roadway surface. 300 mm 300 mm+/- 2 m depending on road width1 m1 mMin Distance Apart - 2 m (Road width = 2 m)               - 3 m (Road width = 4 m)Max Distance Apart – No Limit  Figure 5.1  Adjacent loops connected to different detector modules 4 mm30 – 50 mm  Figure 5.2  Slot details
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 23 of 35  6.  CONFIGURATION   WARNING: 7.  The connector PIN assignments  vary from model to model.  Refer  to  the  label  on  the  side  of  the unit for connector PIN assignment.  NOTE 1: The tables below show the PIN assignments for Nortech’s standard TD236 Enhanced detector models, on other models the pin assignments may change.  WARNING: 8.  The  wiring  harness  is  only  rated  for SELV  voltages  (less  than  60  V  dc  or less than 42 V ac).    If  the  relays  are  to  switch  higher voltages use CE LVD approved 11 pin sockets.   NOTE 2: All relay contact descriptions refer to the tuned and undetected state.   6.1  TD234 Enhanced Detector: English   11 – PIN CONNECTOR WIRING for: 306FT0002 / 306FT0008  302FT0041 WIRING HARNESS WIRE COLOUR 11 PIN ConnectorPin No. Function Red  1  Live Black  2  Neutral  12 – 24V AC/DC ± 10% 45 – 65 Hz  200 mA max Blue  3  Channel 1 Loop Blue  4  Channel 1 Loop  Twist this pair Yellow  5  Channel 2 Loop Yellow  6  Channel 2 Loop  Twist this pair Grey  7  Channel 2 N/O Relay Contact                 or OPTO+ Grey  8  Channel 2 Relay Common Contact         or OPTO- Green/Yellow  9  Earth White  10  Channel 1 N/O Relay Contact                 or OPTO+ White  11  Channel 1 Relay Common Contact         or OPTO-
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 24 of 35  6.2  TD236 Enhanced Detector: English  11 – PIN CONNECTOR WIRING for: 306FT0004  302FT0041 WIRING HARNESS WIRE COLOUR 11 PIN ConnectorPin No. Function Red  1  Live Black  2  Neutral  230 V AC ± 10% 20 mA  50 Hz Blue  3  Channel 1 Loop Blue  4  Channel 1 Loop  Twist this pair Yellow  5  Channel 2 Loop Yellow  6  Channel 2 Loop  Twist this pair Grey  7  Channel 2 N/O Relay Contact                 or OPTO+ Grey  8  Channel 2 Relay Common Contact         or OPTO- Green/Yellow  9  Earth White  10  Channel 1 N/O Relay Contact                 or OPTO+ White  11  Channel 1 Relay Common Contact         or OPTO-   6.3  TD236 Enhanced Detector:   11 – PIN CONNECTOR WIRING   302FT0070 WIRING HARNESS WIRE COLOUR 11 PIN ConnectorPin No. Function Red  1  Live          Black  2  Neutral  230 V AC ± 10% 20 mA  50 Hz Grey  3  Channel 2 N/O Relay Contact Grey  4  Channel 2 Common Contact White  5  Channel 1 N/O Relay Contact White  6  Channel 1 Common Contact Blue  7  Channel 1 Loop Blue  8  Channel 1 Loop  Twist this  Pair Green/Yellow  9  Earth Yellow  10  Channel 2 Loop Yellow  11  Channel 2 Loop  Twist this  Pair   6.4  TD236 Enhanced Detector:   11 – PIN CONNECTOR WIRING   302FT0071 WIRING HARNESS WIRE COLOUR 11 PIN ConnectorPin No. Function Red  1  Live          Black  2  Neutral  120 V AC ± 10% 30 mA  50 Hz Grey  3  Channel 2 Relay Common Contact Green/Yellow  4  Earth White  5  Channel 1 Relay Common Contact White  6  Channel 1 N/O Relay Contact Blue  7  Channel 1 Loop Blue  8  Channel 1 Loop  Twist this  Pair Yellow  9  Channel 2 Loop Yellow  10  Channel 2 Loop  Twist this  Pair Grey   11  Channel 2 N/O Relay Contact
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 25 of 35   WARNING: 9.  The  wiring  harness  wire colour  to  PIN  No. assignment  only  applies  to  the stated wiring harness Part No.    Other  wiring  harnesses  will  have different  wire  colour  to  PIN  No. assignments.      7.  APPLICATIONS  The TD236 Enhanced dual channel detectors can be used in a variety of applications in the traffic and vehicle control environments.  For VA (Vehicle Actuated) or SVA (Semi Vehicle Actuated) traffic intersection control.  Some of the features that make the TD236 Enhanced detector ideal for these purposes have been described in the preceding paragraphs.  For more details on traffic applications refer to ”Traffic Applications Manual”, Document No. MKT04.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 26 of 35  8.  CUSTOMER FAULT ANALYSIS  8.1  Fault Finding    FAULT  CAUSED BY  REMEDY  Red LED does not glow on power up  If the indicator is off then there is a fault on the power connection to the unit.   Check power feed to the unit.  After the initial tune period the Ch1 and/or Ch2 indicator is green. Turning off for half second periods.    Unit cannot tune to the loop due to faulty loop or feeder connection.  Loop may be too small or too large.  Faulty detector unit.  Check loop installation and connections.   Recut as per installation instructions.  Replace unit.   After tuning, the loop output LED’s flashes intermittently and the relay chatters     The loop is getting spurious detects due to:  a)  Crosstalk with       adjacent detector.  b)  Faulty loop or feeder       connection.     a)   Change frequency          setting.  b)  Check that the feeders are correctly connected and        adequately twisted.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 27 of 35  8.2  DU100 – Detector Diagnostic Unit  The DU100 Diagnostic unit is a hand-held test instrument that has been designed to operate with the TD236 Enhanced detector to provide installation/service personnel with positive verification of the correct operation of the vehicle detector and its installation.    The following parameters may be verified using this instrument:  1.  Detector type and version   2.  Loop status   Display of loop frequency and magnitude of current change of loop inductance  %∆L/L.  3.  Frequency    Readout of the actual loop operating frequency and the magnitude of the frequency drift since the last re-tune.  4.  Sensitivity    Displays the Minimum and Maximum changes of Inductance %∆L/L that caused a detect since the last re-tune.  5.  Status    Displays the current status of the detector i.e. Undetect, Detect, Open circuit, Short circuit or Indeterminate.  6.  Time    The time in days and hours since the last re-tune and the reason for the last re-tune i.e. Reset: manual or power failure, Loop short circuit, Loop open circuit,  Indeterminate or an Inductance change of greater than 15 % ∆ L/L (typical).  This historical information is invaluable in providing information about intermittent faults.  7.  Crosstalk    Allows for the comparison of the operating frequencies of Detector loops in close proximity to each other. If the operating frequencies are to close the DU100 test will indicate a failure.   For further information refer to the Diagnostic Unit DU100 User Manual Document No. 895UM0001.  It is highly recommended that after installation of a detector (or if the loop has been changed in any way) that the DU100 Diagnostics Unit is used to verify the correct operation of the detector. A record of the readings should be kept so that if there is a problem in the future a comparison can be made to identify what has changed. The form in Appendix C could be used to record these readings.   8.2.1  Interpretation of the DU 100 readings  8.2.1.1  Frequency    For  the  TD236  Enhanced  Detector  the  Minimum  frequency  is  24  kHz  and  the  Maximum frequency is 78 kHz  If  a  20  µH  loop  is  connected  directly  (no  feeder  cable)  to  the  Detector  and  the  Frequency switches are set to “High Frequency” the typical frequency would be 78 kHz  If a  1000 µH loop is connected directly (no  feeder cable) to the Detector and the Frequency switches are set to “Low Frequency” the typical frequency would be 24 kHz  If the Frequency reading from the DU100 is close to the Minimum Frequency the inductance of the LOOP is too large – you need to remove turns from the loop  If the Frequency reading from the DU100 is close to the Maximum Frequency the inductance of the LOOP is too low and you need to add turns to the loop
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 28 of 35  If  the  detector  is  operating  close  to  either  limit  it  is  possible  that  either  the frequency  drift  caused  by  environmental  changes  or  the  shift  in  frequency caused by a large ∆L/L detect will cause the frequency to go outside the limits and cause a retune.   8.2.1.2   Frequency drift  The  TD236  Enhanced  Detector  can  handle  environmental  conditions  that  can  cause  the frequency to drift up to at a rate of approximating 1% ∆L/L per minute.  If  the  Drift  reading  approaches  this  value  the  detector  will  have  problems  tracking  the environmental change  If the drift is higher than say 0.5 % ∆ L/L per minute this will indicate a possible fault with the loop or feeder cable. Possibly the wire insulation has deteriorated and moisture is causing a short to earth or that wires of the loop are no longer encapsulated and are moving.  For  more  information  about  Frequency  drift  refer  to  the  “Theory  of  Application”  section  in Diagnostic Unit DU100 User Manual Document No. 895UM0001   8.2.1.3   Sensitivity  For a standard loop of 1.0 metres by 2.0 metres with 2 turns (circumference less than 10  meters) and a ten meter feeder cable the following table shows typical sensitivity values  for different vehicle types  VEHICLE TYPE  %∆∆∆∆ L/L Metal Supermarket Trolley   Bicycle  0.04 Motorbike  0.12 Articulated Truck  0.38 SUV (Four Wheel Drive)  0.40 5 Ton Tip Truck  0.45 Motor Car  > 1.00 Forklift  > 1.00  For more information about Sensitivity refer to the “Theory of Application” section in Diagnostic Unit DU100 User Manual Document No. 895UM0001    8.2.1.4   Time  This is a powerful tool in identifying problems with an installation. The time since the last retune of the detector will let you know when the event occurred and the reason will inform you of what caused the event    8.2.1.5   Crosstalk  For  information  about  resolving  crosstalk  refer  to  the  “Theory  of  Application”  section  in Diagnostic Unit DU100 User Manual Document No. 895UM0001
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 29 of 35  8.3  Functional Test  To test a detector, connect it to an inductive loop with a total inductance in the order of 300 micro-henries. (This may be achieved in the workshop by winding (x) turns of wire on a non-metal former of diameter (y)).   x  = 19 turns 0.25 mm wire y  = 238 mm (9.4 inches)   Bring a small metal object approximately the size of a matchbox close to the loop coil. The following will happen on detection:  The relevant channel OUTPUT LED will light up.  The relevant channel PRESENCE output relay will operate  To  check  the  sensitivity,  presence  time  etc.,  use  should  be  made  of  a  calibrated  tester,  which comprises of a calibrated loop similar to the one described above with a moveable vane, which can be moved over the loop at pre-determined heights.  This device together with the DU100 hand-held test instrument will allow comprehensive analysis of the operating characteristics of the detector.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 30 of 35  APPENDIX A - FCC ADVISORY STATEMENT   NOTE: This equipment has been tested and found to comply with the limits of Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.   Operation is subject to the following two conditions:   1  This device may not cause harmful interference, and  2  This device must accept any interference received, including interference that may cause undesired operation  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.   However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  The following booklets prepared by the Federal Communications Commission (FCC) may also prove helpful:  • How to Identify and Resolve Radio-TV Interference Problems (Stock No. 004-000-000345-4) • Interface Handbook (Stock No. 004-000-004505-7)  These booklets may be purchased from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.   WARNING: 10.  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 31 of 35  APPENDIX B – INSTALLATION OUTDOORS   Appendix B.1  IEC 60950-22:2005 – Outdoor cabinet  If the TD236 Enhanced Detector is to be installed outdoors it must be installed in a cabinet / housing that complies with the requirements of IEC 60950-22:2005 for a minimum of pollution degree 2.     Appendix B.2  IEC 60950-22:2005 - Northern Europe  To achieve outdoor operation down to -50 °C as requ ired by IEC 60950-22:2005 for Northern Europe (Finland, Norway and Sweden) a heater with a thermostat must be included in the cabinet that houses the TD236 Enhanced Detector.     Appendix B.3  IEC 60950-1:2005 – Overvoltage Category  If the unit is likely to be exposed to transient overvoltage greater that IEC 60950-1 Overvoltage Category II additional protection must be provided external to the unit on the supply lines.
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 32 of 35  APPENDIX C - REQUEST FOR TECHNICAL SUPPORT FORM   For Technical support please fill in the form below and send it to your supplier. It is recommended that at installation you complete this form as a record of the Installation. If there is a problem later on you can identify what has changed.  For locating faults in “Nortech Inductive Loop Vehicle Detector” installations it is highly recommended that you use the DU100 DIAGNOSTICS UNIT. Please refer to the DU100 user manual Doc. No. 895UM0001 for details of how to operate the DU100.   Contact Details:-  Your Name: ____________________________________________  Your company: ___________________________________________________________________  Telephone No. _______________________   Mobile/Cellphone No. _________________________  FAX No. ____________________________   Email Address _______________________________  Postal address: ____________________________________                            _____________________________________        _____________________________________   Product Model (i.e. TD236) ________________________  Product FT No.   306FT_____________  Product Serial Number: ___________________________   Site Name: _____________________________________ Detector No. (at the site): ______________  What are the settings of the switches on the front of the unit    ON or OFF      Switch  1   ___________  (FREQ  Frequency)      Switch  2   ___________  (FREQ  Frequency)      Switch  3   ___________  (SENS  Sensitivity Channel 2)      Switch  4   ___________  (SENS  Sensitivity Channel 2)      Switch  5   ___________  (SENS  Sensitivity Channel 1 )      Switch  6   ___________  (SENS  Sensitivity Channel 1)      Switch  7   ___________  (ASB    Automatic Sensitivity Boost)      Switch  8   ___________  (PRES  Presence Limited or Permanent)      Switch  9   ___________  (PULSE/PRES  Pulse or Presence Channel 2)      Switch  10  ___________  (PULSE/PRES  Pulse or Presence Channel 1)  What is the position of the internal link:(Pin 1 to 2  OR Pin 2 to 3 OR Open)? ____________________  (refer to section 3.3 above for functions of this link)  What application is this unit used in (short description)______________________________________    _________________________________________________________________________________  _________________________________________________________________________________
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 33 of 35  POWER SUPPLY DETAILS:   Nominal Voltage: _______ V     Minimum Voltage: _______ V    Maximum Voltage: ________ V  AC or DC ?    ______________   If AC then the Frequency _______  Hz  LOOP DETAILS  Channel 1            Channel 2  Size of loop:    ____ m by ____ m      Size of loop:    ____ m by ____ m  Shape of loop: _____________________    Shape of loop: _____________________  Number of Turns: _____         Number of Turns: _____  Size of wire used (mm2 or AWG) _____________  Size of wire used (mm2 or AWG) _____________  Type of wire insulation _____________________  Type of wire insulation _____________________  Thickness of insulation:_____________ mm    Thickness of insulation:____________ mm  How far below the surface is the loop: ________ mm  How far below the surface is the loop: _______ mm  Are there any metal objects below the loops such as concrete reinforcing, water pipes etc if yes please give details:  _____________________________________________________________________________   ____________________________________________________________________________  _____________________________________________________________________________  Are there any power cables below these loops (Yes/No) ____   If yes please give details:  _____________________________________________________________________________   _____________________________________________________________________________   _____________________________________________________________________________  Are there any other loops in the area (Yes/No) ____     If so how many?   ________  and   how close to these loops are they? ________ m  FEEDER CABLE DETAILS  Channel 1            Channel 2  Length of feeder cable ________ m      Length of feeder cable ________ m  Size of wire used (mm2 or AWG) _____________  Size of wire used (mm2 or AWG) _____________ (should be 1.5 mm2   or larger)  Type of wire insulation _____________________  Type of wire insulation _____________________  Thickness of insulation:_____________ mm    Thickness of insulation:____________ mm  Type of feeder cable used (screened, armoured, multicore, etc.)  __________________________________________________________________________  _________________________________________________________________________________
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 34 of 35   In the feeder cable how many twists per meter are there?____________ (should be more than 20 per metre)  Are there any other cables close to these feeder cables? (Yes/No) _____ If yes please give details:   _________________________________________________________________________________   ___________________________________________________________________  FEEDER CABLE and LOOP DETAILS  Channel 1            Channel 2  Is the loop and feeder cable one continuous     Is the loop and feeder cable one continuous piece of wire or is there a joint between the     piece of wire or is there a joint between the loops and the feeder?  (Yes/No) _______      loops and the feeder?  (Yes/No) _______  Please give details:__________________________________________________________________  _________________________________________________________________________________  With the detector disconnected, measure the following:-  Channel 1            Channel 2  AC voltage between the two wires of the     AC voltage between the two wires of the feeder cable __________ V        feeder cable __________ V   AC voltage between one of the feeder cable    AC voltage between one of the feeder cable  wires and earth __________ V        wires and earth __________ V   DC resistance of Feeder plus Loop: _______  ohms  DC resistance of Feeder plus Loop: _______ ohms   Inductance of Feeder plus Loop: ________ µH    Inductance of Feeder plus Loop: ______ µH   Frequency of measurement? ______ KHz      Frequency of measurement? ______ KHz   Loop and feeder resistance to earth      Loop and feeder resistance to earth (with detector unplugged) using a       (with detector unplugged) using a   500V Megger: _________ Mega Ohms      500V Megger: _________ Mega Ohms (should be greater than 10 Mega Ohms)      (should be greater than 10 Mega Ohms)
 306UM0002 - 01  TD236 Enhanced Detector User Manual   Page 35 of 35  READINGS FROM DU100 DIAGNOSTICS UNIT  On arrival at site Time since last retune: ___________ days    _____________ hours   Reason for Retune (Reset: manual or power failure, Short circuit, Open circuit, Indeterminate, Inductance change of greater than 15 % ∆ L/L (typical):        _______________________________________________  Channel 1            Channel 2  Frequency ______________ kHz      Frequency ______________ kHz  Loop Frequency Drift __________ %      Loop Frequency Drift __________ %  Sensitivity  Min: ___________ %∆L/L      Sensitivity  Min: ___________ %∆L/L  Sensitivity Max: ___________  %∆L/L      Sensitivity Max: ___________  %∆L/L  Channel Status:____________________________  Channel Status:____________________________  (Undetect, Detect, Open circuit, Short circuit or Indeterminate)  (Undetect, Detect, Open circuit, Short circuit or Indeterminate)  Inductance Change for each vehicle type (Use the maximum sensitivity reading from the DU100 and reset the detector between each reading):  Vehicle Type  Channel 1 Inductance Change  Channel 2 Inductance Change Bicycle  %∆L/L %∆L/L Motorbike  %∆L/L %∆L/L Car  %∆L/L %∆L/L SUV  %∆L/L %∆L/L Articulated truck  %∆L/L %∆L/L 5 Ton Tip Truck  %∆L/L %∆L/L Forklift  %∆L/L %∆L/L Other type (Please specify)   %∆L/L  %∆L/L  Channel 1            Channel 2  Crosstalk (Pass / Fail): _______________     Crosstalk (Pass / Fail): _______________  (If fail actual frequencies of the two problem detector loops)    (If fail actual frequencies of the two problem detector loops)  Frequency 1:___________kHz        Frequency 1:___________kHz  Frequency 2:______________kHz      Frequency 2:______________kHz  Comments: _______________________________________________________________________  ______________________________________________________________________________________  ______________________________________________________________________________________