Nortek Security and Control 2GIG DW11345 Recessed Door/Window Contact User Manual DW11 IG 77 000002 001 Rev B

2GIG Technologies, Inc. Recessed Door/Window Contact DW11 IG 77 000002 001 Rev B

User manual

Download: Nortek Security and Control 2GIG DW11345 Recessed Door/Window Contact User Manual DW11 IG 77 000002 001 Rev B
Mirror Download [FCC.gov]Nortek Security and Control 2GIG DW11345 Recessed Door/Window Contact User Manual DW11 IG 77 000002 001 Rev B
Document ID1674873
Application IDe9O/D/1DaTskSSCsBVel5Q==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize34.73kB (434176 bits)
Date Submitted2012-04-12 00:00:00
Date Available2012-04-12 00:00:00
Creation Date2017-11-01 02:46:19
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-11-01 02:46:19
Document TitleDW11 IG 77-000002-001 Rev B
Document CreatorAdobe Illustrator CS5.1

Thin Door/Window Contact
2GIG-DW11-345
Operating Instructions
The 2GIG-DW11-345 is a Thin Door/Window Contact that can be installed
on doors, windows, and many other objects that open and close. The
sensor transmits signals to the control panel when a magnet mounted near
the sensor is moved away from or closer to the sensor. The sensor has an
external input that accepts N/C dry contact devices. The sensor is also
equipped with a cover tamper for additional security.
Installation & Mounting Guidelines
Figure 1
Use the following guidelines for internal switch usage:
1 Mount the sensor on the door frame and the magnet on the door. If the sensor is used on
double doors, mount the sensor on the least-used door and the magnet on the most-used
door.
2 If possible, locate sensors within 100 ft (30 m) of the panel. While a transmitter may have a
range of 350 ft (106 m) or more out in the open, the environment at the installation site can
have a significant effect on transmitter range. Sometimes a change in sensor orientation can
help overcome adverse wireless conditions.
3 Make sure the alignment arrow on the magnet points to the alignment mark on the sensor
(see Figure 1).
4 Place sensors at least 4.7 in (12 mm) above the floor to avoid damaging them.
5 Avoid mounting sensors in areas where they will be exposed to moisture or where the sensor
operating temperature range of 32 to 120°F (0 to 49°C) will be exceeded.
6 Use spacers (not included) to keep sensors and magnets away from metal or metallic
surfaces such as foil wallpaper.
7 Avoid mounting sensors in areas with a large quantity of metal or electrical wiring, such as a
furnace or utility room.
To mount the sensor, do the following:
1 Place the base of the sensor in the desired location and secure with included screws (see
Figure 2).
2 When mounting the magnet, line up the arrow on the magnet with the middle line on one
side of the sensor (see Figure 1). Mount the magnet no more than 0.4 in (1 mm) away from
the sensor. Be sure to secure the magnet with adhesive.
To use the external input:
1 Repeat above instructions for mounting.
2 Drill hole through access hole, if needed (see Figure 2).
3 Plug two-pin connector Into J1 (see Figure 3).
4 Connect wire to N/C dry contact device.
Programming
The following steps describe general guidelines for programming (learning) the sensor
into the alarm control panel memory. For more details, refer to the 2GIG Installation &
Programming Instructions.
1 To remove the sensor cover, use your finger to press the tab on the end of the case;
this will disengage the clip holding the cover to the base.
2 Set the panel to sensor learning mode.
3 Press and release the tamper switch (SW1) on the sensor until the panel responds
(see Figure 3).
4 Replace the base of the sensor.
5 Exit program mode.
Access hole for
external input
Screw
mounting
features
Figure 2
Access hole for
external input
Tamper
switch
Battery
Pull Tab
Testing
Figure 3
Before mounting the sensor, verify that the sensor mounting location provides good
RF communication to the panel. To verify, do the following:
1 Put the control panel into sensor test mode.
2 Hold the magnet next to the removable cap on the sensor and then pull the magnet away from
the sensor.
3 Listen for siren or keypad beeps to determine appropriate response (refer to the control panel
installation instructions).
4 Exit sensor test mode.
Note: It is recommended that a system test be performed per the Operation & User's Guide at least once a year.
Battery Installation & Replacement
If a sensor battery is low, a low battery notification will be indicated on the 2GIG Alarm Control Panel's screen. When the
2GIG alarm system Indicates that there is a sensor with a low battery, replace the battery immediately. Use only the
recommended replacement batteries (see Specifications).
To install or replace the battery, do the following:
1 To remove the sensor cover, use your finger to press the tab on the end of the case. This will disengage the clip holding
the cover to the base.
2 Place a small flathead screwdriver in the slot between the metal clip (see Figure 3) and the battery and push it out taking
care not to scratch the battery terminal on the PCB.
3 Insert the replacement battery with the + sign facing out (see Figure 3).
4 Verify programming and RF communication with the panel (see Testing).
WARNING! The polarity of the battery must be observed, as shown (see Figure 2). Improper handling of lithium
batteries may result In heat generation, explosion or fire, which may lead to personal injuries. Replace only with
the same or equivalent type of battery as recommended by the manufacturer (see Specifications).
Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used batteries must be made In
accordance with the waste recovery and recycling regulations In your area.
Keep away from small children. If batteries are swallowed, promptly seek medical attention.
California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY In
California, USA. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.
Specifications
Wireless Signal Range
Code Outputs
Supervisory
Transmitter Frequency
Transmitter Frequency Tolerance
Transmitter Bandwidth
Modulation Type
Unique ID Codes
Supervisory Interval
Peak Field Strength
External Input Sampling Current
External Input
Reed Switch Magnetic Sensitivity
Reed Sensitivity
Magnet Type
Magnet Dimensions (Hx~)
Sensor Dimensions (HxD)
Weight (Including battery & magnet)
Housing Material
Color
Operating Temperature
Relative Humidity
Battery (Installed with pull tab)
Regulatory Listing(s)
Warranty*
Included Accessories
350 ft., open air, with 2GIG Wireless Alarm Control Panel
Alarm Restore; External Alarm; External Restore; Tamper; Tamper Restore
Low Battery
345.000 MHz (crystal controlled)
± 15kHz
24kHz
Amplitude Shift Keying-On/Off Keying (ASK-OOK)
Over one (1) million different code combinations
70 minutes
Typical 36,000 uV /m at 3m
20 uA
Accepts N/C dry contact devices
10 to 20 amp turns
0.625 in. (1.59 em) minimum gap, 0.85 in. (2.16 em) typical
Rare earth
1.3 X 0.435 X 0.312 in. (3.3 X 1.1 X 0.79 cm)
2.59 X 1.03 X 0.49 in. (6.58 X 2.62 X 1.24 cm)
1.1 oz. (31.2 g)
ABS plastic
White
32° to 120°F (0° tO 49°C)
5-95% Non-Condensing
One (1) Panasonic CR2032, or equivalent Lithium batteries
ETL, FCC Part 15, Industry Canada
Two (2) years
Two (2) Phillip's flat-head screws
FCC & INDUSTRY CANADA REGULATORY INFORMATION
FCC ID: WDQ-DW11345
Industry Canada ID: 7794A-DW11345
NOTICE: Unauthorized changes or modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and the receiver
. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
. Consult the dealer or an experienced radio/television technician for help
©2011 2gig Technologies Inc. All Rights Reserved
Technical Support:
1-866-670-1591
www.2gig.com
PN 77-000002-001 Rev B

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Create Date                     : 2012:02:01 14:33:56-07:00
Creator                         : Adobe Illustrator CS5.1
Modify Date                     : 2012:03:27 13:09:52-06:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Title                           : DW11 IG 77-000002-001 Rev B
Metadata Date                   : 2012:03:27 13:09:52-06:00
Creator Tool                    : Adobe Illustrator CS5.1
Thumbnail Width                 : 256
Thumbnail Height                : 200
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 23951 bytes, use -b option to extract)
Instance ID                     : uuid:0bea1131-7a64-43dc-896e-464d232dad12
Document ID                     : xmp.did:F97F1174072068118083C2633EE56ADB
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:b94674f5-eefc-714b-a6ee-d6d433112897
Derived From Document ID        : xmp.did:08801174072068118A6DFE0D6787F09C
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:08801174072068118A6DFE0D6787F09C, xmp.iid:F97F1174072068118083C2633EE56ADB
History When                    : 2012:01:16 11:33:14-07:00, 2012:02:01 14:33:53-07:00
History Software Agent          : Adobe Illustrator CS5.1, Adobe Illustrator CS5.1
History Changed                 : /, /
Manifest Link Form              : EmbedByReference, EmbedByReference, EmbedByReference
Manifest Reference File Path    : /Users/alanottley/Documents/Intertek ETL Listed C US EPS.eps, /Users/alanottley/Documents/2GIG.eps, /Users/alanottley/Documents/2GIG.eps
Startup Profile                 : Print
Has Visible Overprint           : False
Has Visible Transparency        : False
N Pages                         : 1
Max Page Size W                 : 5.000000
Max Page Size H                 : 8.000000
Max Page Size Unit              : Inches
Font Name                       : ArialMT, Arial-BoldMT, MyriadPro-Regular, MyriadPro-Bold
Font Family                     : Arial, Arial, Myriad Pro, Myriad Pro
Font Face                       : Regular, Bold, Regular, Bold
Font Type                       : Open Type, Open Type, Open Type, Open Type
Font Version                    : Version 5.06, Version 5.06, Version 2.062;PS 2.000;hotconv 1.0.57;makeotf.lib2.0.21895, Version 2.062;PS 2.000;hotconv 1.0.57;makeotf.lib2.0.21895
Font Composite                  : False, False, False, False
Font File Name                  : Arial.ttf, Arial Bold.ttf, MyriadPro-Regular.otf, MyriadPro-Bold.otf
Plate Names                     : Black
Swatch Group Name               : Default Swatch Group, Grays, Brights
Swatch Group Type               : 0, 1, 1
Swatch Colorant Swatch Name     : White, Black, CMYK Red, CMYK Yellow, CMYK Green, CMYK Cyan, CMYK Blue, CMYK Magenta, C=15 M=100 Y=90 K=10, C=0 M=90 Y=85 K=0, C=0 M=80 Y=95 K=0, C=0 M=50 Y=100 K=0, C=0 M=35 Y=85 K=0, C=5 M=0 Y=90 K=0, C=20 M=0 Y=100 K=0, C=50 M=0 Y=100 K=0, C=75 M=0 Y=100 K=0, C=85 M=10 Y=100 K=10, C=90 M=30 Y=95 K=30, C=75 M=0 Y=75 K=0, C=80 M=10 Y=45 K=0, C=70 M=15 Y=0 K=0, C=85 M=50 Y=0 K=0, C=100 M=95 Y=5 K=0, C=100 M=100 Y=25 K=25, C=75 M=100 Y=0 K=0, C=50 M=100 Y=0 K=0, C=35 M=100 Y=35 K=10, C=10 M=100 Y=50 K=0, C=0 M=95 Y=20 K=0, C=25 M=25 Y=40 K=0, C=40 M=45 Y=50 K=5, C=50 M=50 Y=60 K=25, C=55 M=60 Y=65 K=40, C=25 M=40 Y=65 K=0, C=30 M=50 Y=75 K=10, C=35 M=60 Y=80 K=25, C=40 M=65 Y=90 K=35, C=40 M=70 Y=100 K=50, C=50 M=70 Y=80 K=70, PANTONE 3005 C, PANTONE 425 U, C=0 M=0 Y=0 K=100, C=0 M=0 Y=0 K=90, C=0 M=0 Y=0 K=80, C=0 M=0 Y=0 K=70, C=0 M=0 Y=0 K=60, C=0 M=0 Y=0 K=50, C=0 M=0 Y=0 K=40, C=0 M=0 Y=0 K=30, C=0 M=0 Y=0 K=20, C=0 M=0 Y=0 K=10, C=0 M=0 Y=0 K=5, C=0 M=100 Y=100 K=0, C=0 M=75 Y=100 K=0, C=0 M=10 Y=95 K=0, C=85 M=10 Y=100 K=0, C=100 M=90 Y=0 K=0, C=60 M=90 Y=0 K=0
Swatch Colorant Mode            : CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK
Swatch Colorant Type            : PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, SPOT, SPOT, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS
Swatch Colorant Cyan            : 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 100.000000, 0.000000, 14.999998, 0.000000, 0.000000, 0.000000, 0.000000, 5.000001, 19.999998, 50.000000, 75.000000, 85.000000, 90.000000, 75.000000, 80.000000, 70.000000, 85.000000, 100.000000, 100.000000, 75.000000, 50.000000, 35.000004, 10.000002, 0.000000, 25.000000, 39.999996, 50.000000, 55.000000, 25.000000, 30.000002, 35.000004, 39.999996, 39.999996, 50.000000, 100.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 85.000000, 100.000000, 60.000004
Swatch Colorant Magenta         : 0.000000, 0.000000, 100.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 100.000000, 90.000000, 80.000000, 50.000000, 35.000004, 0.000000, 0.000000, 0.000000, 0.000000, 10.000002, 30.000002, 0.000000, 10.000002, 14.999998, 50.000000, 95.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 95.000000, 25.000000, 45.000000, 50.000000, 60.000004, 39.999996, 50.000000, 60.000004, 65.000000, 70.000000, 70.000000, 34.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 75.000000, 10.000002, 10.000002, 90.000000, 90.000000
Swatch Colorant Yellow          : 0.000000, 0.000000, 100.000000, 100.000000, 100.000000, 0.000000, 0.000000, 0.000000, 90.000000, 85.000000, 95.000000, 100.000000, 85.000000, 90.000000, 100.000000, 100.000000, 100.000000, 100.000000, 95.000000, 75.000000, 45.000000, 0.000000, 0.000000, 5.000001, 25.000000, 0.000000, 0.000000, 35.000004, 50.000000, 19.999998, 39.999996, 50.000000, 60.000004, 65.000000, 65.000000, 75.000000, 80.000000, 90.000000, 100.000000, 80.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 95.000000, 100.000000, 0.000000, 0.003099
Swatch Colorant Black           : 0.000000, 100.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 10.000002, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 10.000002, 30.000002, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 25.000000, 0.000000, 0.000000, 10.000002, 0.000000, 0.000000, 0.000000, 5.000001, 25.000000, 39.999996, 0.000000, 10.000002, 25.000000, 35.000004, 50.000000, 70.000000, 2.000000, 77.000000, 100.000000, 89.999405, 79.998795, 69.999702, 59.999104, 50.000000, 39.999401, 29.998802, 19.999701, 9.999103, 4.998803, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.003099
Swatch Colorant Tint            : 100.000000, 100.000000
Producer                        : Adobe PDF library 9.90
Page Count                      : 2
For                             : Alan Ottley,
Bounding Box                    : 12 -565 728 -15
Container Version               : 11
Creator Version                 : 15
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WDQ-DW11345