Nortek Security and Control GTO Access SGER GATE EDGE CONTROL UNIT User Manual
GTO Access Systems, LLC GATE EDGE CONTROL UNIT
User Manual
PRINTERS INSTRUCTIONS INSTR,INSTL,SGER SERIES - GTO P/N: 10016916 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 1 of 2 Description PRO ACCESS The SGER series of digital receivers are wireless radio controls designed for use with automatic gate openers or garage door operators. The radio format provides unparalleled security. Receivers and transmitters do not contain a typical “coding switch”. Each transmitter is pre-set at the factory to a unique code. The receiver is programmed by sending a signal to it from the transmitter(s) that are going to be used with it. This stores the transmitters code into the receiver’s memory. The receiver will retain its memory even without power. The receiver will activate only from these “memorized” transmitters. TM SGER DIGITAL GATE RECEIVER The SGER series has an “F” connector for attaching an antenna. The receiver is supplied with a 9-inch local antenna, a three foot 75 ohm coaxial cable, and a bulkhead connector for mounting the antenna outside the gate operator enclosure. RECEIVER 3-FOOT CABLE CASE SCREWS The receivers can operate from 10.5-30 volts DC and are normally powered from the gate operator. The relay contact(s) are rated at 5 amps @ 32 volts AC/DC NEC Class 2 circuit. Installation Instructions MOUNTING HARDWARE NOTE: SGER only works with SGET. LOCAL ANTENNA Linear PRO Access • 3121 Hartsfield Road • Tallahassee, FL 32303 1.800.543.4283 • linearproaccess.com STEP 1 Connect receiver relay output Connect the appropriate channel wires (Ch. 1 - two gray wires)., (Ch. 2 - two yellow wires) to the appropriate activation terminals on the gate operator. STEP 2 Connect receiver to power STEP 3 Connect the red power input wire to the radio power and the black wire to the common terminal on the gate operator. BULKHEAD CONNECTOR NUT WASHER Mount the receiver Use the screws provided to mount the receiver within the operator housing. This provides protection from the elements. Secure case with case screws. MOUNT RECEIVER INSIDE GATE HOUSING COMMON 10.5-30 VOLT DC POWER OPEN OBSTRUCTION INPUT SECURE CASE CLOSED WITH TWO SCREWS AT BOTTOM OF CASE COMMON CLOSE OBSTRUCTION INPUT STEP 4 Connect antenna STEP 5 Connect the coaxial cable to the “F” connector on the receiver. Drill a 3/8” hole on the top of the operator housing for the bulkhead connector. Insert the connector and secure it with the nut and lock washer. Connect the cable and antenna to the bulkhead connector. CONNECT COAXIAL CABLE TO "F" CONNECTOR Open receiver case To open the receiver case, remove the screws, squeeze sides of case and rotate upward. STEP 6a SGER channel one learn switch The pushbutton labeled LEARN 1 is used to program transmitters to channel one. LEARN 1 CHANNEL ONE PUSHBUTTON SLIDE WEATHER RESISTANT CAP OVER CONNECTION LEARN 1 USE THIS PUSHBUTTON TO ENTER A TRANSMITTER INTO CHANNEL ONE INSERT BULKHEAD CONNECTOR THROUGH OPERATOR HOUSING SECURE CONNECTOR TO HOUSING USING WASHER AND NUT CONNECT CABLE TO BULKHEAD CONNECTOR SQUEEZE BOTH SIDES AT TABS AND TILT UPWARD LEARN 2 PRINTERS INSTRUCTIONS INSTR,INSTL,SGER SERIES - GTO P/N: 10016916 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 2 of 2 STEP 6b Connect antenna STEP 7 Program the receiver The pushbutton labeled LEARN 2 is used to program transmitters to channel two. Momentarily press the receiver’s program button. The red programming LED will light. The LED slowly blinks for about 60 seconds. A transmitter must be entered CHANNEL TWO PUSHBUTTON LEARN 2 while the LED is on. Press the desired learn button. The LED will flicker indicating that the receiver has accepted the transmitter and channel relay will toggle. LEARN 1 PRESS THE LEARN BUTTON FOR THE DESIRED CHANNEL (LEARN 1 or LEARN 2) PRESS THE TRANSITTER BUTTON ON THE CONTROL BOARD LEARN 2 LEARN 1 USE THIS PUSHBUTTON TO ENTER A TRANSMITTER INTO CHANNEL TWO NOTE: Be sure to press the receiver program button for less than 2 seconds. S2 THE LED WILL LIGHT AND REMAIN ON ABOUT FIVE SECONDS RECEIVER LED WILL FLICKER AS TRANSMITTER IS ENTERED INTO MEMORY INFO 1 Erasing receiver memory PRESS PROGRAM BUTTON FOR FIVE SECONDS OR MORE LEARN 2 Condition NO Low Battery Open YES No resistance across TB1 and TB2 of SGET No Ack 3 YES SGET not able to send message (dead or too far away) Edge Edge shorted YES LED WILL FLASH, COUNTING THE TOTAL NUMBER OF TRANSMITTERS PROGRAMMED. THEN IT WILL BLINK ONCE (CHANNEL ONE) OR TWICE (CHANNEL TWO) AS THE TRANSMITTERS ARE ERASED. LIMITED WARRANTY IMPORTANT This Linear PRO Access (LPA) product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from LPA or through LPA’s normal distribution channels. LPA does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of LPA for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or re-installation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This LPA Warranty is in lieu of all other warranties express or implied. Linear PRO Access radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact LPA Technical Services at 1-800-543-1236 for an RPA# and other important details Alarm Fault? Code Low Batt 1 WARNING: Changes, modifications or adjustments not expressly approved by GTO Access Systems, LLC could void the user’s authority to operate this equipment. There Are No User Serviceable Parts. DC Operator Wiring GND SENSE Gate Edge Controller DC Operator M2 WARNING: BE SURE GATE AREA IS CLEAR OF OBSTRUCTIONS LEARN 1 SGER M1 TOUCH THE EDGE SENSOR TO ENSURE THE GATE OBSTRUCTS Troubleshooting Transmitters may be erased from the receiver’s memory by pressing and holding the receiver’s program button until the LED blinks one time as the receiver’s memory is erased. Then release the program button. – Test receiver STEP 8 Be sure gate area is clear. Test the units by activating the gate and touching the edge sensor to ensure the gate obstructs. Closed LEARN 1 Open SENSE INPUT NOTICE: This device complies with part 15 of the FCC rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. LEARN 2 SENSE POWER 3.3V NOTE: For AC Operator install an AC Sensor, and refer to the AC Sense instructions book. GND Copyright© 2017 GTO Access Systems, LLC Document Number: 10016916 REV A (05-15-17)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01 Create Date : 2017:05:17 10:38:54-04:00 Metadata Date : 2017:05:17 10:38:57-04:00 Modify Date : 2017:05:17 10:38:57-04:00 Creator Tool : Adobe InDesign CC 2017 (Macintosh) Instance ID : uuid:8e53194f-7215-6741-b748-d708a5cec4b0 Original Document ID : xmp.did:3512ecd6-0e72-46cc-ad64-44fb1365cdf3 Document ID : xmp.id:0c01da27-0b40-4f55-bb91-a3020c4d6353 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:fb75f739-51aa-403a-b5aa-aea6eaf2c992 Derived From Document ID : xmp.did:f61e469c-f290-4383-83f1-2cf11b78b3fe Derived From Original Document ID: xmp.did:3512ecd6-0e72-46cc-ad64-44fb1365cdf3 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Macintosh) History Changed : / History When : 2017:05:17 10:38:54-04:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 2017 (Macintosh)EXIF Metadata provided by EXIF.tools