Nortek Security and Control 00100 SECURITY ALARM TRANSMITTER User Manual 235240A TTLDW01 Tx indd

Nortek Security & Control LLC SECURITY ALARM TRANSMITTER 235240A TTLDW01 Tx indd

Users manual

Copyright © 2013  235240 X11TTLDWO01TTLDWC01UNIVERSALDOOR/WINDOWTRANSMITTERSInstallation InstructionsPRODUCT DESCRIPTIONThe TTLDWO01 and TTLDWC01 are battery powered supervised stationary transmitters. These transmitters can be used in a variety of wireless security and remote sensing applications. Triggering the transmitter with its built-in magnetic switch sends a digitally coded wireless signal to the alarm control.Both models have an optional external input that can be triggered by dry contact devices. The Model TTLDWC01 connects to normally closed (N/C) devices. The Model TTLDWO01 connects to normally open (N/O) devices. The transmitter is programmed using Confi guration Mode to select the internal magnetic switch only, the external contact input only, or both.The transmitter can send fi ve different signal types: fault, restore, low battery, tamper, and status. The system must be programmed to the transmitter’s code before testing and operation. Refer to the alarm control’s instructions for details on programming.In a typical installation, the magnet is mounted on a door or window and the transmitter is mounted on the frame. When the door or window is opened, the magnet moves away from the transmitter and a fault signal is sent. When the door or window is closed, the magnet returns next to the transmitter and a restore signal is sent.About every 65 minutes the transmitter sends a supervisory status signal to update the system. If the battery tests low, a low battery signal is included with any transmission. The transmitter is powered from two 3-Volt CR2032 lithium batteries (included).An internal switch detects if the transmitter’s case is opened. Opening the case will send a tamper signal. Two screws and double-stick tape are provided for mounting the transmitter.FEATURESBATTERY INSTALLATION OR REPLACEMENT INPUT CONFIGURATION MODE OPTIONAL EXTERNAL CONTACTTRANSMITTER MOUNTING PROGRAMMING & TESTING TATTLETALE PORTABLE ALARM SYSTEMS LIMITED WARRANTYThis TATTLETALE PORTABLE ALARM SYSTEMS product is warranted against defects in material and workmanship for a period of one year.  This warranty does not apply in cases of improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, or repair by anyone other than tattletale. This warranty does not cover the replacement of batteries that are used to power the product. There are no obligations or liabilities on the part of TATTLETALE PORTABLE ALARM SYSTEMS for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation or reinstallation.  All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This TATTLETALE PORTABLE ALARM SYSTEMS Warranty is in lieu of all other warranties express or implied.All products returned for warranty service require a Return Merchandise Authorization Number (RMA#).  Contact TATTLETALE Technical Support at 1-888-835-5668 or at www.tattletale.com for an RMA # and other important details.This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.Conformité RéglementaireCe dispositif est conforme à la réglementation de la IC et (Partie 15) de la FCC. Son fonctionnement est soumis à deux conditions : (1) ce dispositif ne doit pas causer d’interférences nuisibles, et (2) ce dispositif doit accepter toute interférence reçue, y compris les interférences pouvant entraîner des conditions de fonctionnement indésirables.Changes or modifi cations to the device may void FCC complianceLes modifi cations apportées à l’appareil peuvent annuler la conformité FCC.www.tattletale.com6269 Frost Road. Westerville OH 43082PRINTER’S INSTRUCTIONS:INSTR,INSTL,TTLDWO&C01 - FILE NAME: 235240 X11- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1TRANSMITTERMAGNETDOUBLE-STICKTAPEEXTERNALCONTACT LEADSMOUNTINGSCREWSMAGNETALIGNMENTMARKSEXTERNALCONTACTMAGNET3 FEET MAXIMUMEXTERNALCONTACTCONNECTORAN EXTERNAL CONTACT CAN BE CONNECTED TO THE TRANSMITTER1PLUG THE EXTERNAL CONTACT LEADS INTO THETRANSMITTER'S EXTERNAL CONTACT CONNECTOR2WIRE THE EXTERNAL CONTACT TO THE LEADSFOR MODEL TTLDWC01 USE NORMALLY CLOSED CONTACTSFOR MODEL TTLDWO01 USE NORMALLY OPEN CONTACTSTRANSMITTER ONDOOR FRAMEMAGNETON DOOROPENING ORCLOSING THE DOORTRIGGERS THETRANSMITTERINSTALLATION TIP: TO MINIMIZE PHYSICAL SHOCK TO THE UNIT, ALWAYS MOUNT THE TRANSMITTER ON THE STATIONARY PART OF THE OPENING1/2" GAPMAXIMUM !!!MOUNT MAGNET NEXTTO ALIGNMENT MARKSATTACH MOUNTING PLATEWITH TWO SCREWS OR USETHE DOUBLE-STICK TAPENOTE: MOUNTING THE TRANSMITTER WITH DOUBLE-STICK TAPE IS NOT ALLOWED IN UL INSTALLATIONS1REFER TO THE SYSTEM'SINSTRUCTIONS AND PLACE THEALARM CONTROL IN PROGRAM MODEVERIFY THAT THE TRANSMITTERHAS BEEN "LEARNED" BYTHE ALARM CONTROL2OPEN OR CLOSE THE PROTECTEDDOOR TO SEND  A SIGNAL3SIGNAL TORECEIVEROPENDOORTEST THE SYSTEM TO VERIFYPROPER OPERATION, CHECKTHAT THE SYSTEM INDICATESWHEN THE DOOR IS OPENOR CLOSED4NOTICE TO USERS IN CALIFORNIA - CR COIN CELL LITHIUM BATTERY INFORMATION: THIS PRODUCT CONTAINS A CR COIN CELL LITHIUM BATTERY WHICH CONTAINS PERCHLORATE MATERIAL - SPECIAL HANDLING MAY APPLY - SEE www.dtsc.ca.gov/hazardouswaste/perchlorateKEEP AWAY FROM SMALL CHILDREN. IF BATTERIES ARE SWALLOWED, PROMPTLY SEE A DOCTOR. DO NOT TRY TO RECHARGE THESE BATTERIES. DISPOSAL OF USED BATTERIES MUST BE MADE IN ACCORDANCE WITH THE WASTE RECOVERY AND RECYCLING REGULATIONS IN YOUR AREA.1TWIST SCREWDRIVER IN SLOTON EITHER SIDE TO OPEN CASEOBSERVEPOLARITY !!!2TWO CR2032 BATTERIESINSTALL WITH + SIDE UPTO REMOVE BATTERIES, TWISTSMALL SCREWDRIVER HERE12CONFIGURATION MODE SELECTS IF THE TRANSMITTER USES THE INTERNALMAGNETIC SWITCH ONLY, THE EXTERNAL CONTACT INPUT ONLY, OR BOTHPRESS AND HOLD THE TAMPER SWITCHTAMPERSWITCHINSTALL THE BATTERIES, RELEASE THETAMPER SWITCH, CONFIGURATIONMODE WILL LAST FOR 15 SECONDSTO SELECT EXTERNAL CONTACT ONLY:BE SURE MAGNET IS AWAY FROM TRANSMITTERAND EXTERNAL CONTACT INPUT IS DISCONNECTEDTO SELECT INTERNAL MAGNETIC SWITCH ONLY:BE SURE THE EXTERNAL INPUT IS DISCONNECTED,MOVE MAGNET NEXT TO TRANSMITTER (BY THETAMPER SWITCH) FOR A MINIMUM OF ONE SECONDWHILE IN CONFIGURATION MODE:TO SELECT EXTERNAL CONTACT & INTERNAL SWITCH:BE SURE MAGNET IS AWAY FROM TRANSMITTER,CONNECT EXTERNAL CONTACT INPUT WIRESTOGETHER FOR A MINIMUM OF ONE SECOND MOVE MAGNETNEXT TO UNITFOR INTERNALMAGNETIC SWITCHUSE ONLYTO ENTER CONFIGURATION MODE:

Navigation menu