Nortek Security and Control 00115 Wireless glass break detector User Manual 235512A GB00Z 1 Iris Instructions indd

Nortek Security & Control LLC Wireless glass break detector 235512A GB00Z 1 Iris Instructions indd

Contents

Instructions1

Copyright © 2013 Linear Corporation  235512 X8GB00Z-1WIRELESSGLASS BREAKDETECTORInstallation Instructions1. PRODUCT DESCRIPTIONThe Model GB00Z-1 is a battery powered glass break detector with built-in Z-Wave® interoperable two-way RF mesh networking technology designed for use with Lowe’s Iris® Smart Home Hub. This device is used for perimeter protection.The GB00Z-1 can send fi ve different signal types: fault, restore, low battery, status, and tamper. The Iris system hub must be paired with the glass break detector before system testing and operation. Refer to the Lowe’s Iris system Web site for details on pairing and testing the detector.In a typical installation, the detector is mounted on a wall or ceiling within 15 feet of the protected glass window(s). The unit uses dual-stage digital audio processing to detect the sound of breaking glass in a 360° area around the device. If the unit detects breaking glass, a fault signal is sent to the system followed by a restore signal.Periodically, the unit sends a status signal to update the system. If the battery tests low, a low battery signal is included with any transmission. The glass break detector is powered from two 3-Volt CR123A lithium batteries (included).An internal switch senses if the detector is removed from its base. Removing the detector will send a tamper signal to the system.Three screws and screw anchors are provided for mounting the detector.2. FEATURES3. INSTALLING OR CHANGING BATTERIES 4. PAIRING OR UN-PAIRING THE DETECTOR WITH THE HUB 5. MOUNTING THE DETECTOR6. DETECTOR TESTING 7. SPECIFICATIONS Operating Temperature: 32° to 120° F (0° to 49° C)  Operating Relative Humidity:  5 to 95%, non-condensing Operating Frequency: 908.42 MHz Battery Type: Two 3-Volt CR123A Lithium Batteries Sensor Type: Single microphone,    dual-stage (thud & crash)The minimum size for all glass types is 11” x 11” (28 cm x 28 cm) square. Glass must be framed, in a wall of the room or mounted in a barrier of 36” (91 cm) minimum width.GLASS TYPE MINIMUM TO MAXIMUM THICKNESSPLATE 1/8” TO 1/4” (3.2 mm TO 6.4 mm)TEMPERED 1/8” TO 1/4” (3.2 mm TO 6.4 mm)SEALED, INSULATING 1/8” TO 1/4” (3.2 mm TO 6.4 mm)Z-Wave is a registered trademark of Sigma Designs Inc. and/or its subsidiaries.8. LINEAR LIMITED RETAIL WARRANTYLinear LLC (the Company) warrants to the original purchaser that products delivered hereunder will be free of defects in materials and workmanship for a period of one (1) year from the date of purchase.The Company within said period shall at its option, either repair or replace free of charge, any product or part thereof found, upon the Company’s inspection, to be so defective, and will return the repaired or replaced product to the purchaser at Company’s expense.All products returned for warranty service require a Return Product Authorization Number (RPA#). For warranty service, shipping instructions, and an RPA#, contact Linear Technical Services at 1-800-421-1587. Devices must be sent to the Company at owner’s expense and be accompanied with statement of defect and proof of purchase.This warranty is conditioned on the following:1.  The Company must be notified within one year of purchase and have been given the opportunity of inspection by return of any alleged defective product free and clear of all liens and encumbrances to the Company or its distributor; and2.  The product must not have been abused, misused or improperly maintained and/or repaired during such period; and3.  Such defect has not been caused by corrosion or exposure to other than ordinary wear and tear.THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.The Company’s maximum liability hereunder is limited to the purchased price of the product. In no event shall the Company be liable for any consequential, indirect, incidental or special damages of any nature arising from the sale or use of the product, whether based in contract, tort, strict liability or otherwise.Note: Some states do not allow limitations on incidental or consequential damages or how long an implied warranty lasts, so that the above limitations may not fully apply. This warranty gives specific legal rights and you may also have other rights which may vary from state to state.This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.PRINTER’S INSTRUCTIONS:INSTR,INSTL,GLASS BREAK,ZW - P/N: 235512 X8 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - FOLDING: 4-FOLD ALTERNATE, FINISH WITH LOGO SHOWING - SCALE: 1-1GLASS BREAKDETECTORRED2ND STAGEINDICATORGREEN1ST STAGEINDICATORDETECTIONMICROPHONEREMOVABLEMOUNTINGBASEMOUNTINGSCREWSAND ANCHORSTESTBUTTONBASEALIGNMENTINDICATORSINSERT TWOCR123A BATTERIESINTO BATTERYHOLDERSWARNINGDANGER OF EXPLOSION IF BATTERIES ARE INSTALLED INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER.OBSERVEPOLARITY !!!GREEN INDICATORWILL FLASH ONCEWHEN BATTERIESARE INSTALLEDLOCATE THE DETECTOR ON THEADJACENT OR OPPOSITE WALLOR ON THE CEILING WITHIN15 FEET OF THE WINDOW BEINGPROTECTED12USE THE MOUNTING BASE AS ATEMPLATE TO MARK THE LOCATIONOF THE THREE MOUNTING HOLES3DRILL 3/16" PILOT HOLES FOR THESCREW ANCHORS AND PUSHTHE ANCHORS INTO THE HOLES4ATTACH THE MOUNTING BASEWITH THE THREE SCREWS NOTE: WHEN WALL MOUNTING,ORIENT THE TEST BUTTON DOWN5ATTACH THE DETECTOR TO THEBASE, MATCH THE ALIGNMENTMARKS AND TURN CLOCKWISENOTE: IF THE BATTERIES ARE NOTINSTALLED, THE DETECTOR WILLNOT ALLOW MOUNTING TO THE BASEMOUNTINGSCREWS1FROM THE IRIS WEB SITE, CLICK THEDEVICES TAB2ON THE GLASS BREAK DETECTORDEVICE CLICK "MANAGE"3CLICK TEST4FOLLOW THE ON-SCREEN INSTRUCTIONSTO TEST THE DETECTOR WITH THE HUBWHEN INSTRUCTED,PRESS THE BUTTONON THE DETCTOR3 TIMESAFTER INSTALLING BATTERIES, WAIT5 SECONDS FOR THE POWER UP DELAY12FROM THE IRIS WEB SITE, CLICK THEDEVICES TAB, THEN CLICK THE "ADD DEVICES" BUTTON5FOLLOW THE ON-SCREEN INSTRUCTIONSTO PAIR THE DETECTOR WITH THE HUB4PLACE DETECTOR WITHIN10 FEET OF THE IRIS SYSTEM HUBWHEN INSTRUCTED,PRESS THE BUTTONON THE DETCTOR3SELECT GLASS BREAK DETECTORFROM THE LIST1FROM THE IRIS WEB SITE, CLICK THEDEVICES TAB2ON THE GLASS BREAK DETECTORDEVICE CLICK "MANAGE"3CLICK REMOVE4FOLLOW THE ON-SCREENINSTRUCTIONS TO UN-PAIR THEDETECTOR WITH THE HUBPARING THEDETECTORUN-PARING THEDETECTORTO ADDTO HUBTO REMOVEFROM HUBUSA & Canada (800) 421-1587 & (800) 392-0123(760) 438-7000 - Toll Free FAX (800) 468-1340www.linearcorp.com

Navigation menu