Nortek Security and Control DW319 Security/Remote Control Transmitter User Manual 235345A ITIDWA01 Instructions indd

Nortek Security & Control LLC Security/Remote Control Transmitter 235345A ITIDWA01 Instructions indd

User manual

Copyright © 2013 Linear Corporation  235345 X6ITIDWA01UNIVERSALDOOR/WINDOWTRANSMITTERInstallation InstructionsPRODUCT DESCRIPTIONThe ITIDWA01 is a battery powered supervised stationary transmitter designed for use with GE security systems. Triggering the transmitter with its built-in magnetic switch sends a digitally coded wireless signal to its companion receiver. The transmitter also has an external input that accepts normally closed (N/C) dry contact devices.The ITIDWA01 can send fi ve different signal types: fault, restore, low battery, tamper, and status. Receivers must be programmed to the transmitter’s code before system testing and operation. Refer to the receiver’s instructions for details on programming.In a typical installation, the magnet is mounted on a door or window and the transmitter is mounted on the frame. When the door or window is opened, the magnet moves away from the transmitter and a fault signal is sent. When the door or window is closed, the magnet returns next to the transmitter and a restore signal is sent.About every 65 minutes the transmitter sends a status signal to update the receiver. If the battery tests low, a low battery signal is included with any transmission. The transmitter is powered from two 3-Volt CR2032 lithium batteries (included).An internal switch detects if the transmitter’s case is opened. Opening the case will send a tamper signal to the receiver.Two screws and double-stick tape are provided for mounting the transmitter.FEATURESBATTERY INSTALLATION OR REPLACEMENT PROGRAMMING OPTIONAL EXTERNAL CONTACTTRANSMITTER MOUNTING SPECIFICATIONS Operating Temperature: 32° to 120° F (0° to 49° C)  Operating Relative Humidity: 5 to 95%, non-condensing Operating Frequency: 319.5 MHz Battery Type: Two 3-Volt CR2032 Lithium BatteriesLINEAR LIMITED WARRANTYPRINTER’S INSTRUCTIONS:INSTR,INSTL,ITIDWA - LINEAR P/N: 235345 X6- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - FOLDING: 4 FOLD ALTERNATE, FINISH WITH LOGO SHOWING - SCALE: 1-1TRANSMITTERMAGNETDOUBLE-STICKTAPEEXTERNALCONTACT LEADSMOUNTINGSCREWSMAGNETALIGNMENTMARKSEXTERNALNORMALLYCLOSEDCONTACTMAGNET3 FEET MAXIMUMEXTERNALCONTACTCONNECTORAN EXTERNAL NORMALLY CLOSED MAGNETICCONTACT CAN BE CONNECTED TO THE TRANSMITTER1PLUG EXTERNAL CONTACT LEADS INTO THETRANSMITTER'S EXTERNAL CONTACT CONNECTOR2WIRE EXTERNAL CONTACT TO THE LEADSNOTE: THE INTERNAL MAGNETIC SWITCH CANNOT BE USEDIF AN EXTERNAL CONTACT IS CONNECTEDTRANSMITTER ONDOOR FRAMEMAGNETON DOOROPENING ORCLOSING THE DOORTRIGGERS THETRANSMITTERINSTALLATION TIP: TO MINIMIZE PHYSICAL SHOCK TO THE UNIT, ALWAYS MOUNT THE TRANSMITTER ON THE STATIONARY PART OF THE OPENING1/2" GAPMAXIMUM !!!MOUNT MAGNET NEXTTO ALIGNMENT MARKSATTACH MOUNTING PLATEWITH TWO SCREWS OR USETHE DOUBLE-STICK TAPENOTE: MOUNTING THE TRANSMITTER WITH DOUBLE-STICK TAPE IS NOT ALLOWED IN UL INSTALLATIONSWARNINGDANGER OF EXPLOSION IF BATTERY IS INSTALLED INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER.NOTICE TO USERS IN CALIFORNIA - CR COIN CELL LITHIUM BATTERY INFORMATION: THIS PRODUCT CONTAINS A CR COIN CELL LITHIUM BATTERY WHICH CONTAINS PERCHLORATE MATERIAL - SPECIAL HANDLING MAY APPLY - SEE www.dtsc.ca.gov/hazardouswaste/perchlorateKEEP AWAY FROM SMALL CHILDREN. IF BATTERIES ARE SWALLOWED, PROMPTLY SEE A DOCTOR. DO NOT TRY TO RECHARGE THESE BATTERIES. DISPOSAL OF USED BATTERIES MUST BE MADE IN ACCORDANCE WITH THE WASTE RECOVERY AND RECYCLING REGULATIONS IN YOUR AREA.1TWIST SCREWDRIVER IN SLOTON EITHER SIDE TO OPEN CASEOBSERVEPOLARITY !!!2INSTALL TWO CR2032 BATTERIES+ SIDE UPTO REMOVE BATTERIES, TWISTSMALL SCREWDRIVER HEREUSA & Canada (800) 421-1587 & (800) 392-0123(760) 438-7000 - Toll Free FAX (800) 468-1340www.linearcorp.com1REFER TO THE SECURITY SYSTEM'SINSTRUCTIONS AND PLACE THERECEIVER IN PROGRAM MODESET ANY OTHER SYSTEMPROGRAMMING OPTIONS FORTHE TRANSMITTER2PRESS AND RELEASE THE TAMPERSWITCH TO SEND  A SIGNAL4AFTER INSTALLATION, TEST THESYSTEM TO VERIFY PROPEROPERATION, CHECK THAT THESYSTEM INDICATES WHEN THEDOOR IS OPEN OR CLOSED5VERIFY THAT THE TRANSMITTERHAS BEEN "LEARNED" BYTHE RECEIVER3PRESS AND RELEASETHE TAMPER SWITCHThis Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied.All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-855-546-3351 for an RPA# and other important details.Any changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Les changements ou modifi cations non approuvés expressément par la partie responsable de la conformité pourrait annuler l’autorité de l’utilisateur à faire fonctionner l’équipement.IMPORTANT! Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed.• For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.• A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.• Changes or modifi cations to the device may void FCC compliance.• Infrequently used radio links should be tested regularly to protect against undetected interference or fault.• A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Navigation menu