Nortek Security and Control DW319 Security/Remote Control Transmitter User Manual 235345A ITIDWA01 Instructions indd

Nortek Security & Control LLC Security/Remote Control Transmitter 235345A ITIDWA01 Instructions indd

User manual

Copyright © 2013 Linear Corporation 235345 X6
ITIDWA01
UNIVERSAL
DOOR/WINDOW
TRANSMITTER
Installation Instructions
PRODUCT DESCRIPTION
The ITIDWA01 is a battery powered supervised stationary transmitter designed for use
with GE security systems. Triggering the transmitter with its built-in magnetic switch
sends a digitally coded wireless signal to its companion receiver. The transmitter also
has an external input that accepts normally closed (N/C) dry contact devices.
The ITIDWA01 can send fi ve different signal types: fault, restore, low battery, tamper,
and status. Receivers must be programmed to the transmitter’s code before system
testing and operation. Refer to the receiver’s instructions for details on programming.
In a typical installation, the magnet is mounted on a door or window and the
transmitter is mounted on the frame. When the door or window is opened, the magnet
moves away from the transmitter and a fault signal is sent. When the door or window
is closed, the magnet returns next to the transmitter and a restore signal is sent.
About every 65 minutes the transmitter sends a status signal to update the receiver.
If the battery tests low, a low battery signal is included with any transmission. The
transmitter is powered from two 3-Volt CR2032 lithium batteries (included).
An internal switch detects if the transmitter’s case is opened. Opening the case will
send a tamper signal to the receiver.
Two screws and double-stick tape are provided for mounting the transmitter.
FEATURES
BATTERY INSTALLATION OR REPLACEMENT PROGRAMMING OPTIONAL EXTERNAL CONTACT
TRANSMITTER MOUNTING SPECIFICATIONS
Operating Temperature: 32° to 120° F (0° to 49° C)
Operating Relative Humidity: 5 to 95%, non-condensing
Operating Frequency: 319.5 MHz
Battery Type: Two 3-Volt CR2032 Lithium Batteries
LINEAR LIMITED WARRANTY
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,ITIDWA - LINEAR P/N: 235345 X6- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - FOLDING: 4 FOLD ALTERNATE, FINISH WITH LOGO SHOWING - SCALE: 1-1
TRANSMITTER
MAGNET
DOUBLE-STICK
TAPE
EXTERNAL
CONTACT LEADS
MOUNTING
SCREWS
MAGNET
ALIGNMENT
MARKS
EXTERNAL
NORMALLY
CLOSED
CONTACT
MAGNET
3 FEET MAXIMUM
EXTERNAL
CONTACT
CONNECTOR
AN EXTERNAL NORMALLY CLOSED MAGNETIC
CONTACT CAN BE CONNECTED TO THE TRANSMITTER
1
PLUG EXTERNAL CONTACT LEADS INTO THE
TRANSMITTER'S EXTERNAL CONTACT CONNECTOR
2
WIRE EXTERNAL CONTACT TO THE LEADS
NOTE: THE INTERNAL MAGNETIC SWITCH CANNOT BE USED
IF AN EXTERNAL CONTACT IS CONNECTED
TRANSMITTER ON
DOOR FRAME
MAGNET
ON DOOR
OPENING OR
CLOSING THE DOOR
TRIGGERS THE
TRANSMITTER
INSTALLATION TIP: TO MINIMIZE PHYSICAL SHOCK
TO THE UNIT, ALWAYS MOUNT THE TRANSMITTER
ON THE STATIONARY PART OF THE OPENING
1/2" GAP
MAXIMUM !!!
MOUNT MAGNET NEXT
TO ALIGNMENT MARKS
ATTACH MOUNTING PLATE
WITH TWO SCREWS OR USE
THE DOUBLE-STICK TAPE
NOTE: MOUNTING THE TRANSMITTER WITH
DOUBLE-STICK TAPE IS NOT ALLOWED IN
UL INSTALLATIONS
WARNING
DANGER OF EXPLOSION IF BATTERY IS
INSTALLED INCORRECTLY. REPLACE ONLY
WITH THE SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER.
NOTICE TO USERS IN CALIFORNIA - CR COIN CELL LITHIUM BATTERY
INFORMATION: THIS PRODUCT CONTAINS A CR COIN CELL LITHIUM
BATTERY WHICH CONTAINS PERCHLORATE MATERIAL - SPECIAL
HANDLING MAY APPLY - SEE
www.dtsc.ca.gov/hazardouswaste/perchlorate
KEEP AWAY FROM SMALL CHILDREN. IF BATTERIES ARE
SWALLOWED, PROMPTLY SEE A DOCTOR. DO NOT TRY TO
RECHARGE THESE BATTERIES. DISPOSAL OF USED BATTERIES
MUST BE MADE IN ACCORDANCE WITH THE WASTE RECOVERY
AND RECYCLING REGULATIONS IN YOUR AREA.
1
TWIST SCREWDRIVER IN SLOT
ON EITHER SIDE TO OPEN CASE
OBSERVE
POLARITY !!!
2
INSTALL TWO CR2032 BATTERIES
+ SIDE UP
TO REMOVE BATTERIES, TWIST
SMALL SCREWDRIVER HERE
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
1
REFER TO THE SECURITY SYSTEM'S
INSTRUCTIONS AND PLACE THE
RECEIVER IN PROGRAM MODE
SET ANY OTHER SYSTEM
PROGRAMMING OPTIONS FOR
THE TRANSMITTER
2
PRESS AND RELEASE THE TAMPER
SWITCH TO SEND A SIGNAL
4
AFTER INSTALLATION, TEST THE
SYSTEM TO VERIFY PROPER
OPERATION, CHECK THAT THE
SYSTEM INDICATES WHEN THE
DOOR IS OPEN OR CLOSED
5
VERIFY THAT THE TRANSMITTER
HAS BEEN "LEARNED" BY
THE RECEIVER
3
PRESS AND RELEASE
THE TAMPER SWITCH
This Linear product is warranted against defects in material and workmanship
for twelve (12) months. This warranty extends only to wholesale
customers who buy direct from Linear or through Linear’s normal
distribution channels. Linear does not warrant this product to consumers.
Consumers should inquire from their selling dealer as to the nature of the
dealer’s warranty, if any. There are no obligations or liabilities
on the part of Linear LLC for consequential damages arising
out of or in connection with use or performance of this
product or other indirect damages with respect to loss of
property, revenue, or profi t, or cost of removal, installation,
or reinstallation. All implied warranties, including implied warranties for
merchantability and implied warranties for fi tness, are valid only until the
warranty expires. This Linear LLC Warranty is in lieu of all other
warranties express or implied.
All products returned for warranty service require a Return Product
Authorization Number (RPA#). Contact Linear Technical Services at
1-855-546-3351 for an RPA# and other important details.
Any changes or modifi cations not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Les changements ou modifi cations non approuvés expressément par la partie
responsable de la conformité pourrait annuler l’autorité de l’utilisateur à faire
fonctionner l’équipement.
IMPORTANT! Linear radio controls provide a reliable communications link
and fi ll an important need in portable wireless signaling. However, there are
some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC
Rules and Regulations as Part 15 devices. As such, they have limited
transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time
and may be blocked by radio signals that occur on or near their operating
frequencies, regardless of code settings.
Changes or modifi cations to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect
against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to
acting as a wholesale distributor or dealer, and these facts should be
communicated to the ultimate users.
This device complies with FCC Part 15 and Canada Rules and Regulations.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables
aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2)
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.

Navigation menu