Norton 7100SZ Series Safe Zone With External Sensor Installation And Instruction Manual 80 9371 0084 020

User Manual: Norton 7100SZ Series SafeZone with External Sensor Installation and Instruction Manual Installation

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadNorton  7100SZ Series Safe Zone With External Sensor Installation And Instruction Manual 80-9371-0084-020
Open PDF In BrowserView PDF
7100SZ Series SafeZone®
External Sensor
ASSA ABLOY
Installation and Instruction
Manual

ASSA ABLOY

Patent Pending

4.76
(120)

3.14
(79.8)

2.0
(50.8)

Tools required:
• Power drill
• Center punch
• Wire stripper

• Allen wrench set (inch)
• Flat blade screwdriver (potentiometer & terminal size)
• Screwdriver (Phillips size 2)
• Tape rule

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

Table of Contents:
Mechanical Installation
Wiring Diagrams
Sensor Settings
Sensing Field Settings
Trouble Shooting
Specifications
Safety Precautions

2
3
4
5
5
6
6

1

80-9371-0084-020 (01-14)

Opening the sensor
ASSA ABLOY

Mechanical Installation
1. Apply adhesive backed template, supplied with
sensor, to appropriate surface and aligned with
centerline of door on side of opening opposite
from SafeZone Mount.

MOUNTING TEMPLATE
DRILL
1/8” HOLE

DRILL
1/8” HOLE

2. Drill two 1/8" holes for mounting.
3. Drill one 1/4" hole for cable access.
4. Insert mounting screws into mount surface, but
do not screw them fully in.

DRILL 1/4” HOLE
THEN INSERT CABLE

PLACE TEMPLATE
AT LEASE 1” ABOVE
BOTTOM OF HEADER

5. Route wiring through backplate.
6. Mount sensor backplate and tighten screws.
7. Complete wiring connections and sensor setup
and testing.
8. Secure sensor cover to backplate.

*

2.0"
Frame Fac
e

MOUNTIN
DRILL
1/8” HOLE

G TEMPLA
TE
DRILL
1/8” HOLE
PLACE TEMP
LATE
AT LEASE
BOTTOM 1” ABOVE
OF HEAD
ER

DRILL 1/4”
HOLE
THEN INSER
T CABLE

*

1.0" Min.
Above Fra

me Face

Electrical

10'-0" Max
he
Above floo ight
r surface

Cable

CL Of D
oor

*

Note:
If frame face is 3.0" or greater,
Sensor can be mounted on frame
face.
See page 3 for Wiring Diagrams
See page 4 for Sensor Adjustments

For optional cable routing, notch
cover in one of the areas shown.
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

2

80-9371-0084-020 (01-14)

Wiring Diagram
(Wiring external sensor to SafeZone Unit)
120VAC
External Sensor

ASSA ABLOY
5 4 3 2 1

Red
Jumper Wire
Black

Green

5 4 3 2 1

L
N
G

Closer
Solenoid
SafeZone Unit 120VAC
Terminal
1 (Red)

Connection
24 VDC (+)

2 (Black)
24 VDC (-)
3 (White)
Relay Common
4 (Green)
Relay N.O.
5
Relay N.C.
Note: Input power tolerance is +/- 10% for
AC, and -10% to +30% for DC power.

Wiring Diagram
(Wiring external sensor to SafeZone Unit)
24VDC

External Sensor
5 4 3 2 1

Red
Jumper Wire
Green

5 4 3 2 1

Black

24VDC (-)
24VDC (+)

Closer
Solenoid

SafeZone Unit 24VDC

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

3

80-9371-0084-020 (01-14)

ASSA ABLOY

Sensor Settings

Wire Knockouts
(Inside Cover)

Hold Time Buttons

Terminal Block

Cover removal slot

Increase (+)

Decrease (-)

Planner Antenna
(Narrow)

Wire
Passage

LED

Front Cover

Lateral and Angular
Antenna Adjustments

Default Factory Settings:
Sensitivity
3
Hold Time
10 seconds
Immunity
2
Detection Mode
1 (Bidirectional)
Door Control Mode 1

Hold Time
Hold open time is defined as the amount of time the door will remain open
AFTER movement in opening is no longer detected.
Setting Hold Open Time:
Press and release the Increase
(+) or decrease (-) buttons until
desired setting is achieved.
Reset Hold Time to Default:
Holding both buttons depressed
simultaneously for 3 seconds
will set unit at default hold time
of 10 seconds.

Setting
0
1
2
3
4
5 (Default)
6
7
8
9

Time (Seconds)
0.5
5
6
7
8
10
14
16
18
20

Setting 1-3

Setting 4-6

Setting 7-9

Recommended Hold Time Settings

Sensitivity Setting
Sensitivity is factory set at setting #3. The sensitivity range is (0 - 9). This setting
can be adjusted along with other advanced settings when using the optional
remote.

Optional remote for advanced setting.
List number 7100REM

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

4

80-9371-0084-020 (01-14)

ASSA ABLOY

Sensing Field Adjustments
The position of the sensing field is determined by the vertical and lateral angle of the antenna.
Lateral Angle Adjustments

Vertical Angle Adjustments

0º

Sensing field as close to the door as possible: Sensing field close to the door:
Antenna is set at the position of 30°
Antenna is set at the position of 0°

Mounting Height:
Sensitivity:
Immunity:
Direction Mode:
Door Control:
Vertical Tilt:
Lateral Tilt:

+15°

Sensing field far from the door:
Antenna is set at the position of 45°

32" 16"

Nominal Detection Pattern with Sensor Set as follows:

-15°

45º

30º

0

7'-2"
3 (factory default)
2 (factory default)
1 (Bi-Directional; factory default)
1 (factory default)
30°
0°

16" 32"

0
16"
32"

Altering the lateral tilt angle will shift the detection
pattern left or right of center.

48"

Note:
Always “walk” the opening during senor adjustment to
confirm the detection pattern is adequate for the
opening and application.
Adjusted hole open times as required for application.
See page 4 for hold open time settings.

Troubleshooting
SYMPTOMS
Red LED does not light up.
(No power to sensor)

PROBABLE CAUSE
Power switch is off.
Loose wire connection.

CORRECTIVE ACTION
Turn power switch to “ON” position.
Inspect wiring for loose connections.

Door Stops several times in Sensitivity is set too high
the same cycle without
sensing presence in the door
way.

Change sensitivity setting using
optional remote.

Door not closing when cover Eye is sensing the closer
installed.
cover.

Adjust the sensing field away from
cover edge. (See “Sensing Field
Adjustments” above.

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

5

80-9371-0084-020 (01-14)

®

SafeZone

ASSA ABLOY

Sensor Technical Specifications
DESCRIPTION

SPECIFICATION

Frequency:
Supply voltage:
Mounting height:
Tilt angle:

24.125 GHz
24 VDC: -10% / +30%:
Normal: 7’; Maximum: 10’-0”
0 to 90 vertical
-15 to +15 lateral

Detection area:
Wide
Narrow
Minimum detection speed:
Power consumption:
Standard output relay:
Max contact voltage
Max contact current
Max switching power
Hold time:
Temperature range:
Dimensions:
Weight:
Material:

13ft (W) x 6.5ft (D)
6.5ft (W) x 8.2ft (D) (supplied as optional)
2 in/sec. (measured in axis)
<2W
60 VDC / 125 VAC
1 A (resistive)
30W (DC) / 60VA (AC)
0.5 sec. to 9 sec. (adjustable)
-4°F to 131°F
4.75in (W) x 3.15in (H) x 2.0in (D)
0.5lbs
ABS

Safety Precautions
•
•
•
•
•

•

Shut off all power going to the header before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by
the door.
Always check placement of all wiring and components before powering up to ensure that moving door parts will not
catch any wires and cause damage to equipment.
Ensure compliance with all applicable safet y standards upon completion of installation.

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
Circuit board components are vulnerable to damage by electrostatic discharge
(ESD). ESD can cause immediate or subtle damage to sensitive electronic parts.
An electrostatic charge can build up on the human body and then discharge when
you touch a board. A discharge can be produced when walking across a carpet
and touching a board, for example. Before handling any board, make sure you
dissipate your body’s charge.

CAUTION: In the event a unit needs to be opened, observe the following precautions.
•
•

•
•

Ground yourself by touching a conductive surface of the door or other element connected to common earth
ground to discharge the static electricity present in your body.
Avoid walking around while replacing items inside the case, especially if you are on carpet or during
conditions of low temperature and low humidity.
Handle the board by the edges only to avoid touching electronic components.
Store a loose board in an anti-static bag.

ASSA ABLOY
3000 Highway 74 East • Monroe, NC 28112
Tel: (877)- 974-2255 • Fax: (800)-338-0965
www.nor tondoorcontrols.com

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

6

80-9371-0084-020 (01-14)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Profile CMM Type                : Lino
Profile Version                 : 2.1.0
Profile Class                   : Display Device Profile
Color Space Data                : RGB
Profile Connection Space        : XYZ
Profile Date Time               : 1998:02:09 06:49:00
Profile File Signature          : acsp
Primary Platform                : Microsoft Corporation
CMM Flags                       : Not Embedded, Independent
Device Manufacturer             : IEC
Device Model                    : sRGB
Device Attributes               : Reflective, Glossy, Positive, Color
Rendering Intent                : Perceptual
Connection Space Illuminant     : 0.9642 1 0.82491
Profile Creator                 : HP
Profile ID                      : 0
Profile Copyright               : Copyright (c) 1998 Hewlett-Packard Company
Profile Description             : sRGB IEC61966-2.1
Media White Point               : 0.95045 1 1.08905
Media Black Point               : 0 0 0
Red Matrix Column               : 0.43607 0.22249 0.01392
Green Matrix Column             : 0.38515 0.71687 0.09708
Blue Matrix Column              : 0.14307 0.06061 0.7141
Device Mfg Desc                 : IEC http://www.iec.ch
Device Model Desc               : IEC 61966-2.1 Default RGB colour space - sRGB
Viewing Cond Desc               : Reference Viewing Condition in IEC61966-2.1
Viewing Cond Illuminant         : 19.6445 20.3718 16.8089
Viewing Cond Surround           : 3.92889 4.07439 3.36179
Viewing Cond Illuminant Type    : D50
Luminance                       : 76.03647 80 87.12462
Measurement Observer            : CIE 1931
Measurement Backing             : 0 0 0
Measurement Geometry            : Unknown
Measurement Flare               : 0.999%
Measurement Illuminant          : D65
Technology                      : Cathode Ray Tube Display
Red Tone Reproduction Curve     : (Binary data 2060 bytes, use -b option to extract)
Green Tone Reproduction Curve   : (Binary data 2060 bytes, use -b option to extract)
Blue Tone Reproduction Curve    : (Binary data 2060 bytes, use -b option to extract)
Page Count                      : 6
Create Date                     : 2014:01:27 09:58:07-05:00
Modify Date                     : 2014:01:27 09:58:07-05:00
Producer                        : Corel PDF Engine Version 16.1.0.843
Author                          : Tadlock;Robert
Creator                         : CorelDRAW X6
Title                           : Untitled-1
EXIF Metadata provided by EXIF.tools

Navigation menu