Norton 7100SZ Series Safe Zone With External Sensor Installation And Instruction Manual 80 9371 0084 020
User Manual: Norton 7100SZ Series SafeZone with External Sensor Installation and Instruction Manual Installation
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
7100SZ Series SafeZone® External Sensor ASSA ABLOY Installation and Instruction Manual ASSA ABLOY Patent Pending 4.76 (120) 3.14 (79.8) 2.0 (50.8) Tools required: • Power drill • Center punch • Wire stripper • Allen wrench set (inch) • Flat blade screwdriver (potentiometer & terminal size) • Screwdriver (Phillips size 2) • Tape rule Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Table of Contents: Mechanical Installation Wiring Diagrams Sensor Settings Sensing Field Settings Trouble Shooting Specifications Safety Precautions 2 3 4 5 5 6 6 1 80-9371-0084-020 (01-14) Opening the sensor ASSA ABLOY Mechanical Installation 1. Apply adhesive backed template, supplied with sensor, to appropriate surface and aligned with centerline of door on side of opening opposite from SafeZone Mount. MOUNTING TEMPLATE DRILL 1/8” HOLE DRILL 1/8” HOLE 2. Drill two 1/8" holes for mounting. 3. Drill one 1/4" hole for cable access. 4. Insert mounting screws into mount surface, but do not screw them fully in. DRILL 1/4” HOLE THEN INSERT CABLE PLACE TEMPLATE AT LEASE 1” ABOVE BOTTOM OF HEADER 5. Route wiring through backplate. 6. Mount sensor backplate and tighten screws. 7. Complete wiring connections and sensor setup and testing. 8. Secure sensor cover to backplate. * 2.0" Frame Fac e MOUNTIN DRILL 1/8” HOLE G TEMPLA TE DRILL 1/8” HOLE PLACE TEMP LATE AT LEASE BOTTOM 1” ABOVE OF HEAD ER DRILL 1/4” HOLE THEN INSER T CABLE * 1.0" Min. Above Fra me Face Electrical 10'-0" Max he Above floo ight r surface Cable CL Of D oor * Note: If frame face is 3.0" or greater, Sensor can be mounted on frame face. See page 3 for Wiring Diagrams See page 4 for Sensor Adjustments For optional cable routing, notch cover in one of the areas shown. Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 2 80-9371-0084-020 (01-14) Wiring Diagram (Wiring external sensor to SafeZone Unit) 120VAC External Sensor ASSA ABLOY 5 4 3 2 1 Red Jumper Wire Black Green 5 4 3 2 1 L N G Closer Solenoid SafeZone Unit 120VAC Terminal 1 (Red) Connection 24 VDC (+) 2 (Black) 24 VDC (-) 3 (White) Relay Common 4 (Green) Relay N.O. 5 Relay N.C. Note: Input power tolerance is +/- 10% for AC, and -10% to +30% for DC power. Wiring Diagram (Wiring external sensor to SafeZone Unit) 24VDC External Sensor 5 4 3 2 1 Red Jumper Wire Green 5 4 3 2 1 Black 24VDC (-) 24VDC (+) Closer Solenoid SafeZone Unit 24VDC Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 3 80-9371-0084-020 (01-14) ASSA ABLOY Sensor Settings Wire Knockouts (Inside Cover) Hold Time Buttons Terminal Block Cover removal slot Increase (+) Decrease (-) Planner Antenna (Narrow) Wire Passage LED Front Cover Lateral and Angular Antenna Adjustments Default Factory Settings: Sensitivity 3 Hold Time 10 seconds Immunity 2 Detection Mode 1 (Bidirectional) Door Control Mode 1 Hold Time Hold open time is defined as the amount of time the door will remain open AFTER movement in opening is no longer detected. Setting Hold Open Time: Press and release the Increase (+) or decrease (-) buttons until desired setting is achieved. Reset Hold Time to Default: Holding both buttons depressed simultaneously for 3 seconds will set unit at default hold time of 10 seconds. Setting 0 1 2 3 4 5 (Default) 6 7 8 9 Time (Seconds) 0.5 5 6 7 8 10 14 16 18 20 Setting 1-3 Setting 4-6 Setting 7-9 Recommended Hold Time Settings Sensitivity Setting Sensitivity is factory set at setting #3. The sensitivity range is (0 - 9). This setting can be adjusted along with other advanced settings when using the optional remote. Optional remote for advanced setting. List number 7100REM Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 4 80-9371-0084-020 (01-14) ASSA ABLOY Sensing Field Adjustments The position of the sensing field is determined by the vertical and lateral angle of the antenna. Lateral Angle Adjustments Vertical Angle Adjustments 0º Sensing field as close to the door as possible: Sensing field close to the door: Antenna is set at the position of 30° Antenna is set at the position of 0° Mounting Height: Sensitivity: Immunity: Direction Mode: Door Control: Vertical Tilt: Lateral Tilt: +15° Sensing field far from the door: Antenna is set at the position of 45° 32" 16" Nominal Detection Pattern with Sensor Set as follows: -15° 45º 30º 0 7'-2" 3 (factory default) 2 (factory default) 1 (Bi-Directional; factory default) 1 (factory default) 30° 0° 16" 32" 0 16" 32" Altering the lateral tilt angle will shift the detection pattern left or right of center. 48" Note: Always “walk” the opening during senor adjustment to confirm the detection pattern is adequate for the opening and application. Adjusted hole open times as required for application. See page 4 for hold open time settings. Troubleshooting SYMPTOMS Red LED does not light up. (No power to sensor) PROBABLE CAUSE Power switch is off. Loose wire connection. CORRECTIVE ACTION Turn power switch to “ON” position. Inspect wiring for loose connections. Door Stops several times in Sensitivity is set too high the same cycle without sensing presence in the door way. Change sensitivity setting using optional remote. Door not closing when cover Eye is sensing the closer installed. cover. Adjust the sensing field away from cover edge. (See “Sensing Field Adjustments” above. Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 5 80-9371-0084-020 (01-14) ® SafeZone ASSA ABLOY Sensor Technical Specifications DESCRIPTION SPECIFICATION Frequency: Supply voltage: Mounting height: Tilt angle: 24.125 GHz 24 VDC: -10% / +30%: Normal: 7’; Maximum: 10’-0” 0 to 90 vertical -15 to +15 lateral Detection area: Wide Narrow Minimum detection speed: Power consumption: Standard output relay: Max contact voltage Max contact current Max switching power Hold time: Temperature range: Dimensions: Weight: Material: 13ft (W) x 6.5ft (D) 6.5ft (W) x 8.2ft (D) (supplied as optional) 2 in/sec. (measured in axis) <2W 60 VDC / 125 VAC 1 A (resistive) 30W (DC) / 60VA (AC) 0.5 sec. to 9 sec. (adjustable) -4°F to 131°F 4.75in (W) x 3.15in (H) x 2.0in (D) 0.5lbs ABS Safety Precautions • • • • • • Shut off all power going to the header before attempting any wiring procedures. Maintain a clean & safe environment when working in public areas. Constantly be aware of pedestrian traffic around the door area. Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door. Always check placement of all wiring and components before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment. Ensure compliance with all applicable safet y standards upon completion of installation. ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS Circuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the human body and then discharge when you touch a board. A discharge can be produced when walking across a carpet and touching a board, for example. Before handling any board, make sure you dissipate your body’s charge. CAUTION: In the event a unit needs to be opened, observe the following precautions. • • • • Ground yourself by touching a conductive surface of the door or other element connected to common earth ground to discharge the static electricity present in your body. Avoid walking around while replacing items inside the case, especially if you are on carpet or during conditions of low temperature and low humidity. Handle the board by the edges only to avoid touching electronic components. Store a loose board in an anti-static bag. ASSA ABLOY 3000 Highway 74 East • Monroe, NC 28112 Tel: (877)- 974-2255 • Fax: (800)-338-0965 www.nor tondoorcontrols.com Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 6 80-9371-0084-020 (01-14)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 6 Create Date : 2014:01:27 09:58:07-05:00 Modify Date : 2014:01:27 09:58:07-05:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : Tadlock;Robert Creator : CorelDRAW X6 Title : Untitled-1EXIF Metadata provided by EXIF.tools