Norton 7290MPI, 7290 MPS Overhead Concealed Closer/Holder 80 9372 1071 020
User Manual: Norton 7290MPI, 7290 MPS Overhead Concealed Closer/Holder Installation
Open the PDF directly: View PDF .
Page Count: 6
Download | ![]() |
Open PDF In Browser | View PDF |
Support Unit Models 7290 MPI (Infinite Hold Open Range) ASSA ABLOY Range) 7290 MPS (Selective Hold-Open ASSA ABLOY Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device with Rigid Slide Arm For wood or metal doors 1- 3/4” to 2 -1/4" (45-57mm) thick Hung in a hollow metal frame Standard butt hinges 80-9372-1071-020 (01-14) CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility of misapplication or misadjustment. Typical Installation • One track & closer position for all door opening angles • Easy arm attachment • Removable Frame Stop Required*-Not Shown Hinge or Pivot Right Hand Door-RH Left Hand Reverse-LHR Left Hand Door-LH Right Hand Reverse-RHR Hinge or Pivot *Not required when frame rabbet exceeds 2-3/16" (56mm). Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9372-1071-020 (01-14) Model 7290MPI/7290MPS Multi-Point Electromechanical Overhead Concealed With Rigid Slide Arm Templa-te Standard Butt Hinges ASSA ABLOY Viewed From Above 4 Holes for Closer Fasteners 3/8 (9.5) 2 (50.8) 1-1/4 (31.8) 22-1/4 (565.2) 3/8 (9.5) 2 (50.8) 7/8 Dia. Hole (22.2) (Conduit) 23 (584.2) C L Conduit 20-1/4 Ref. (514.4) 1" (25.4) CL Closer Dust Box (By frame mfr.) Conduit Box 5/32 to Centerline (4.0) Of Conduit Hole Reinforcement (By frame mfr.) CL 1/8 Ref. (3.2) Removable Frame Stop (By frame mfr.) 21 (533.4) Frame Reinforcements Min. 1-3/4 (44.5) C L Hinge Viewed From Above 11/16 (to edge of cutout) (17.5) 4 Holes for Track Fasteners 1-1/4 (31.8) Max. 2-1/4 (57.2) 1" (25.4) 1" (25.4) 14 (355.6) 2-1/2 (63.5) 1/8 (3.2) 3/8 (9.5) Hinge 1/4 (6.4) C L Door and Track C L Door and Track 8 (203.2) 1-3/16 (30.2) 3-3/4 (95.3) LEFT HAND DOOR 5/8 (15.9) 22 (558.8) 24 3/8 (9.5) deep cutout in shaded area (609.6) 24 (609.6) Fastener NOTES: • Do not scale drawing. • Left hand door shown. • Hardware dimensions shown (not cutouts). • Dimensions are in inches (mm). • Minimum door width 27" (685.8). • Track 24" (609.6) long. • Maximum width hinge is 5" (127). 1/4-20 machine screw #14 wood screw Preparation Use metal frame #7 (.201" dia.) or 5.10mm. drill and 1/4-20 tap metal door wood door 7/32" or 5.5mm. drill Track Installation Door Angle 180° 110° Auxiliary Door Stop Required With Without Cushion and Cushion and stop block Stop block Opening greater than 110º See installation sequence on pages 4 & 5. Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Page 2 80-9372-1071-020 (01-14) Model 7290MPI/7290MPS Multi-Point Electromechanical Overhead Concealed With Rigid Slide Arm Components ASSA ABLOY Plug (MPS Unit only) Closer Assembly Conduit Box Cover Cam Plug (MPS & MPI Unit) H in ge Conduit Knockout L (5) Dress Plate Mounting Screws 6-32 x 3/8 long S S/D Spring Tube Conduit Box P B Short Dress Plate Self Clinching Studs Positioning Screw Mounting Plate Cushion and Stop Block Arm Track Flat Washer with countersink (4) Mounting screws 1-4-20 x 5/8 long (2) Arm/track screw 1/4-20 x 3/4” long Hex drive with thread lock (4) Track screws 1/4-20 x 7/16” or 14-10 x 1-1/4” long wood screws Long Dress Plate Arm Slider This end of slider (short side) toward cushion and stop block. Align Squares Stud Slider Screw Pack Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Page 3 80-9372-1071-020 (01-14) Installation Sequence Note: Read instructions entirely prior to installation. ASSA ABLOY Door/Frame Prep: • Determine hand of door from illustration on page 1. Closer are handed. Hand of closer must match hand of door. • Using template dimensions on page 2, locate holes and cutouts in frame and door, unless a separate template has been supplied for your application. 12 Door: Prepare door for track. Drill and tap (4) holes for 1/4-20 machine screws. 3 Frame: Prepare the frame for mounting closer. Drill and tap (4) holes for 1/4-20 machine screws or #14 wood screws. Note: Generally on new construction hardware cutouts are made by suppliers at their shop. Wiring: • Wiring of switch must be in compliance with N.E.C. Class 2 wiring specifications. • Voltage to unit must be the same as shown on the unit: 24 Volts AC/DC or 120 Volts AC, 60hz. Voltage must be within a range of plus 10% and minus 15% of the unit's stated voltage. Terminal Block FUSE 0.75 AMPS (+) • Pull hook-up box off mounting plate's self clinching studs, disconnect plugs and remove hook-up box cover. (-) VI (+) (-) TEST SWITCH 3 2 1 ALARM PANEL DOOR HOLDER CIRCUIT • Anchor conduit at 1 or 2 hook-up box knockouts. • Secure power input leads to terminal lock, positions #1 and #2 as shown. SPECIFICATIONS 120VAC Voltage MAX. 120V 132V 102V MIN. Current .035 AMPS 24VDC 24VAC 24V 26.4V MAX. 20.4V MIN. 26.4V MAX. 24V 20.4V MIN. .070 AMPS .070 AMPS FUSE VoltageTest Socket Pos. (+) Black OPTIONAL SELECTIVE HOLD OPEN SWITCH SOLENOID COIL Reconnect sockets a. Connect plug with white leads from solenoid for MPI and MPS units. b. Connect plug with black leads from cam switch if used. Replace hook-up box cover and secure with (2) screws. Test switch (Push) VoltageTest Socket Neu. (-) white Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Reattached hook-up box to mounting plate by aligning (2) holes at bottom of hook-up box with (2) self clinching studs. See illustration on page 3. Page 4 80-9372-1071-020 (01-14) Installation Sequence con't ASSA ABLOY • Determine door opening angle See page 2 and below. • Series 7290MPI: Infinite Hold Open units will hold door at virtually any degree of door opening from 5° to 175°. • Series 7290MPS: Selective Open Hold units are shipped with hold open set at approximately 85°. Hold open can be set from 5° to 175°. The hold open position can be increased or decreased by loosening the cam screw, rotating the cam to the new setting and tighten cam screw. See chart below for cam settings where hold open range will start. • Mount closer to frame. Position spring tube away from hinge and mounting plate flush with frame rabbet. Secure to frame reinforcements with (4) 1/4 -20 x 5/8 screws. Use care to avoid damaging or pinching wires. • Install arm on closer pinion (see illustration below) Position arm counterbore facing down with index mark aligned with pinion index mark. Install onto pinion. Secure with washer and flat head arm screw with thread lock (see page 3). Left hand Arm in position • Align letters on hold open cam with “V” centerline of switch rocker. Choose row of letters on cam that are closest to the hinge side face of door. Setting G H J K Door Angle 15º 30º 45º 60º L Right hand (Bottom View) Pinion Mark Arm Index Mark M 90º 135º NOTE: Verify setting of cam before mounting closer to the frame. • Install track in door. Place the assembled track into door cutout with open side up, cushion and stop block if used, toward the hinge. Move slider to the opposite end of track (see illustration, page 3). Secure track with (4) 1/4-20 machine screws. • Connect arm to track. Open door to approximately 5" (127mm), rotate arm to slider and place end on stud. Use a screw driver to align the square on slider’s stud with the arm square (see illustration on page 3). Push down on arm to seat stud and to prevent stud from rotating. Secure with arm/track screw, 1/4-20 x 5/8” long flat head hex drive with thread lock. Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Page 5 80-9372-1071-020 (01-14) Model 7290MPI/7290MPS Multi-Point Electromechanical Overhead Concealed With Rigid Slide Arm Closer Adjustment CAUTION: ASSA ABLOY Do not back valves out of closer or a leak will result. Standard Door Closer Door Closing Controls "L" Range Door Opening Controls "BC" "S" Closing Power Adjustment Range Range Never Close Completely INCREASE MODEL 7290 SIZE HAND RH 4 BC LATCH BC POWER ADJUST POSITION SWEEP DECREASE Mounting Base Plate Closing Controls Latch Opening Controls Sweep Delayed Action • Closer Controls accessible through mounting plate for closer adjustment: Use 1/8" (3mm.) hex-key for valve adjustments. Use standard screwdriver for power adjustment. • Power Adjustment permits increasing door closing force. Controlled by slotted screw marked "P.A." Backcheck VoltageTest Socket Pos. (+) Black FUSE • Closing Speed controlled by valves marked "SWEEP" and "LATCH". Attention: Adjust closing speed time to between 4 to 7 seconds from 90°. Use of the door by handicapped, elderly, or small children may require greater closing time. • Backcheck cushions or slows the opening of a door that is forced to travel faster than conditions require. Backcheck controlled by valves marked "BC POSITION" (open for backcheck start at a greater door opening angle) and "BC" (for adjusting backcheck intensity). Never close "BC" valve completely. • Optional Enhanced Backcheck provides adjustable backcheck intensity beginning at approximately 15° of the door opening cycle. Backcheck positioning valve is omitted when this feature is provided. Test switch (Push) VoltageTest Socket Neu. (-) white • Hold Open Check. Turn power to the unit “On”. Open door to the hold open position. Manually pull door out of hold open and release, door should close. • Hook-Up Box Testing. Open door to the hold open position. Depress “Test Switch” button on Hook-up Board, accessible through cutout in hook-up box and mounting plate (see illustration at right). Door should close. 3000 Highway 74 East • Monroe, NC 28112 Tel: (877)- 974-2255 • Fax: (800)-338-0965 www.nor tondoorcontrols.com • Install short and long dress plates with (5) 6-32 screws. Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. ASSA ABLOY Page 6 80-9372-1071-020 (01-14)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 6 Create Date : 2014:01:13 12:06:21-05:00 Modify Date : 2014:01:13 12:06:21-05:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : McNally;Tommy Creator : CorelDRAW X6 Title : Untitled-1EXIF Metadata provided by EXIF.tools