Norton 7290MPI, 7290 MPS Overhead Concealed Closer/Holder 80 9372 1071 020

User Manual: Norton 7290MPI, 7290 MPS Overhead Concealed Closer/Holder Installation

Open the PDF directly: View PDF PDF.
Page Count: 6

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9372-1071-020 (01-14)
ASSA ABLOY
Multi-Point Electromechanical
Overhead Concealed Closer
Holder Releasing Device
with Rigid Slide Arm
80-9372-1071-020 (01-14)
7290 MPI
7290 MPS
(Infinite Hold Open Range)
(Selective Hold-Open Range)
Support Unit Models
For wood or metal doors 1- 3/4” to 2 -1/4" (45-57mm) thick
Standard butt hinges
Hung in a hollow metal frame
Typical Installation
• Removable Frame Stop Required*-Not Shown
• One track & closer position for all door opening angles
• Easy arm attachment
An incorrectly installed or improperly
adjusted door closer can cause property
damage or personal injury. These instructions
should be followed to avoid the possibility
of misapplication or misadjustment.
CAUTION
*Not required when frame rabbet exceeds 2-3/16" (56mm).
Hinge or
Pivot
Right Hand Door-RH
Left Hand Reverse-LHR
Hinge or
Pivot Left Hand Door-LH
Right Hand Reverse-RHR
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9372-1071-020 (01-14)
Page 2
See installation sequence on pages 4 & 5.
Hinge
Door
and
Track
14
(355.6) 22
(558.8)
3/8 (9.5) deep cutout in shaded area
8
(203.2)
1"
(25.4)
4 Holes
for Track
Fasteners
Viewed From Above
11/16
(17.5)
24
(609.6)
20-1/4
1/8 Ref.
Conduit Box
Reinforcement
(By frame mfr.)
1"
(25.4)
21
(533.4)
Frame Reinforcements
C
L
Ref.
C
L
Conduit
22-1/4
(565.2)
23
(584.2)
Viewed From Above
3/8
(9.5)
1-1/4
(31.8)
2
(50.8)
4 Holes
for Closer Fasteners
C
L
Track Installation
Door Angle Auxiliary Door
Stop Required
110° 180°
With
Cushion and
stop block
Without
Cushion and
Stop block
Opening
greater
than 110º
Templa-te Standard Butt Hinges
2-1/4
(57.2)
Min.
Removable
Frame Stop
(By frame mfr.) 3/8
(9.5)
1-3/16
(30.2)
3-3/4
(95.3)
LEFT
HAND DOOR
Dust Box
(By frame mfr.)
Closer
5/32
(4.0)
Dia. Hole
(Conduit)
2-1/2
(63.5)
1/8
(3.2)
C
L
Multi-Point Electromechanical
Overhead Concealed
Model 7290MPI/7290MPS
With Rigid Slide Arm
NOTES:
• Do not scale drawing.
• Left hand door shown.
• Hardware dimensions shown (not
cutouts).
• Dimensions are in inches (mm).
• Minimum door width 27" (685.8).
• Track 24" (609.6) long.
• Maximum width hinge is 5" (127).
3/8
(9.5)
2
(50.8)
(514.4)
(3.2)
1-3/4
(44.5)
(to edge of cutout)
1"
(25.4)
24
(609.6)
1-1/4
(31.8)
5/8
(15.9)
Fastener Use Preparation
1/4-20 machine
screw
#14 wood screw
metal frame
and
metal door
wood
door
#7 (.201" dia.) or . drill
1/4-20 tap
5.10mm
7/32" or drill5.5mm.
7/8
(22.2)
to Centerline
Of Conduit Hole
C
L
Max.
C
LDoor and Track
1/4
(6.4)
Hinge
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9372-1071-020 (01-14)
Page 3
S
L
S/D
P
B
Conduit Knockout
Dress Plate
Mounting Screws
6-32 x 3/8 long
(5)
(4)
Mounting screws
1-4-20 x 5/8 long
Conduit Box
Plug
(MPS Unit only)
Cam
Plug
(MPS & MPI Unit)
Short
Dress Plate
Track screws
1/4-20 x 7/16”
or
14-10 x 1-1/4” long
wood screws
Positioning
Screw
Cushion and
Stop Block
(4)
Track
(2)
Arm/track screw
1/4-20 x 3/4” long
Hex drive with
thread lock
Slider
Arm
Flat Washer
with
countersink
Screw Pack
Align Squares
Stud
Arm
Slider
This end of slider (short
side) toward cushion
and stop block.
Components
Multi-Point Electromechanical
Overhead Concealed
Model 7290MPI/7290MPS
With Rigid Slide Arm
Conduit Box Cover
Closer Assembly
Spring
Tube
Hinge
Self Clinching Studs
Mounting Plate
Long Dress Plate
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9372-1071-020 (01-14)
Page 4
Note: Generally on new construction hardware
cutouts are made by suppliers at their shop.
Reconnect sockets
. Connect plug with black leads from cam switch
if used.
Reattached hook-up box to mounting plate by aligning
(2) holes at bottom of hook-up box with (2) self clinching
studs. See illustration on page 3.
a. Connect plug with white leads from solenoid for
MPI and MPS units.
b
Replace hook-up box cover and secure with (2) screws.
Installation Sequence
3
2
1DOOR HOLDER
CIRCUIT
ALARM PANEL
FUSE
0.75 AMPS (+)
(-)
VI
(-)
(+)
SOLENOID
COIL
OPTIONAL SELECTIVE
HOLD OPEN
SWITCH
TEST
SWITCH
SPECIFICATIONS
Voltage
Current
120VAC 24VAC 24VDC
120V 24V 24V
.070 AMPS
.070 AMPS
.035 AMPS
132V MAX.
102V MIN.
26.4V MAX.
20.4V MIN.
26.4V MAX.
20.4V MIN.
FUSE VoltageTest
Socket
Pos. (+) Black
VoltageTest
Socket
Neu. (-) white
Test switch
(Push)
123
Terminal Block
Door/Frame Prep:
Note: Read instructions entirely prior to installation.
Wiring:
Wiring of switch must be in compliance with N.E.C.
Class 2 wiring specifications.
Voltage to unit must be the same as shown on the unit:
24 Volts AC/DC or 120 Volts AC, 60hz. Voltage must be
within a range of plus 10% and minus 15% of the unit's
stated voltage.
• Pull hook-up box off mounting plate's self clinching
studs, disconnect plugs and remove hook-up box
cover.
• Anchor conduit at 1 or 2 hook-up box knockouts.
• Secure power input leads to terminal lock, positions #1
and #2 as shown.
• Determine hand of door from illustration on page 1.
Closer are handed. Hand of closer must match hand of
door.
• Using template dimensions on page 2, locate holes
and cutouts in frame and door, unless a separate
template has been supplied for your application.
Door:
Prepare door for track. Drill and tap (4) holes for 1/4-20
machine screws.
Frame:
Prepare the frame for mounting closer. Drill and tap (4)
holes for 1/4-20 machine screws or #14 wood screws.
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9372-1071-020 (01-14)
Page 5
Setting
Door Angle
G H J K L M
135º
15º 30º 45º 60º 90º
• Determine door opening angle
the hinge side face of door.
See page 2 and below.
units
will hold door at virtually any degree of
door opening from
Selective Open Hold
units are shipped with hold open set at
The hold open position can be increased
or decreased by loosening the cam screw,
rotating the cam to the new setting and
tighten cam screw. See chart below for cam
settings where hold open range will start.
• Align letters on hold open cam with
“V” centerline of switch rocker. Choose
row of letters on cam that are closest to
• Series 7290MPI: Infinite Hold Open
• Series 7290MPS:
to 175°.
• Mount closer to frame.
Position spring tube away from hinge and
mounting plate flush with frame rabbet.
Secure to frame reinforcements with (4)
1/4 -20 x 5/8 screws. Use care to avoid damaging
or pinching wires.
• Install arm on closer pinion (see illustration below)
Position arm counterbore facing down with
index mark aligned with pinion index mark. Install
onto pinion. Secure with washer and flat head arm
screw with thread lock (see page 3).
Arm in position
(Bottom View)
Pinion Mark
Right hand
Left hand
Arm Index Mark
• Install track in door.
Place the assembled track into door cutout with
open side up, cushion and block if used, toward
the hinge. Move slider to the opposite
end of track (see illustration, page 3). Secure track
with (4) 1/4-20 machine screws.
stop
Connect arm to track. Open door to approximately
5" (127mm), rotate arm to slider and place end on
stud. Use a screw driver to align the square on slider’s
stud with the arm square (see illustration on page 3).
Push down on arm to seat stud and to prevent stud
from rotating. Secure with arm/track screw,
1/4-20 x 5/8” long flat head hex drive with thread
lock.
NOTE: Verify setting of cam before
mounting closer to the frame.
Installation Sequence con't
approximately 85°. Hold open can be set
from 5° to 175°.
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2002, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9372-1071-020 (01-14)
Page 6
3000 Highway 74 East • Monroe, NC 28112
Tel: (877)- • Fax: (800)-338-0965974-2255
ww w.no r to nd oo rc on tr ols.c om
ASSA ABLOY
accessible through mounting plate for closer adjustment:
Use 1/8" (3mm.) hex-key for valve adjustments.
Use standard screwdriver for power adjustment.
• Closer Controls
permits increasing door closing force.
Controlled by slotted screw marked "P.A."
• Power Adjustment
controlled by valves marked "SWEEP" and "LATCH".
Attention: Adjust closing speed time to between 4 to 7 seconds from 90°.
Use of the door by handicapped, elderly, or small children may require
greater closing time.
• Closing Speed
cushions or slows the opening of a door that is forced
to travel faster than conditions require.
Backcheck controlled by valves marked "BC POSITION" (open for
backcheck start at a greater door opening angle) and "BC" (for
adjusting backcheck intensity). Never close "BC" valve completely.
• Backcheck
Delayed Action Backcheck
Sweep
Latch
Closing Controls Opening Controls
CAUTION:
Do not back valves out of
closer or a leak will result.
Closer Adjustment
Standard
Door Closer Closing Power Adjustment
Door Closing Controls Door Opening Controls
Never Close Completely
"BC"
Range
"L"
Range "S"
Range
provides adjustable backcheck intensity
beginning at approximately 15° of the door opening cycle. Backcheck
positioning valve is omitted when this feature is provided.
• Optional Enhanced Backcheck
BC BC
POSITION
MODEL SIZE
4
HAND
RH
7290 LATCH SWEEP POWER ADJUST
INCREASE
DECREASE
Mounting Base Plate
• Hook-Up Box Testing.
Turn power to the unit “On”. Open door to the hold open
position. Manually pull door out of hold open and release, door should close.
Open door to the hold open position. Depress “Test
Switch” button on Hook-up Board, accessible through cutout in hook-up
box and mounting plate (see illustration at right). Door should close.
• Install short and long dress plates with (5) 6-32 screws.
FUSE
VoltageTest
Socket
Pos. (+) Black
VoltageTest
Socket
Neu. (-) white
Test switch
(Push)
Multi-Point Electromechanical
Overhead Concealed
Model 7290MPI/7290MPS
With Rigid Slide Arm
Hold Open Check.

Navigation menu