Norton Master (PTDO) Or Support (PTO) Units, Push Pull Side 80 9377 0716 020
User Manual: Norton Master (PTDO) or Support (PTO) Units, Push or Pull Side Installation
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Power Track® Series Master Unit – PTDO (with detector) Support Unit - PTO (without detector) ASSA ABLOY CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility of misapplication or misadjustment. Models Hinge (Pull) Side of Stop (Push) Side of Door Application Door Application ASSA ABLOY 7705PTDO 7705PTO Installation Instructions Combination Door Closer-Holder and Releasing Device WITH and WITHOUT Integral Smoke Detector 7705PTDO PULL SIDE illustrated LH – Left Hand Door RHR – Right Hand Reverse NOTES: - For wiring of PTDO models, see "PowerTrack®" "Wiring Instructions" No. 80-9342-0902-021 (01-09) - When used with a PTDO model, PTO unit must be a 24V unit P7705PTDO PUSH SIDE illustrated LH – Left Hand Door RHR – Right Hand Reverse PTO UNITS NOT SHOWN Preparation for Fasteners Components: 9/64" Hex Drive Socket Screw PTOHB24 PTOHB120 Arm Assembly 7700ST-1A 2 Cover Screws PTO Track PTO24 PTO120 Pull (Hinge) Side Push (Stop) Side 7700M * 7700P PPTDO Hook-Up Box PPTDOHB24 PPTDOHB120 PPTO24 PPTO120 PPTOHB24 PPTOHB120 L S L S P D P Delayed Action Option PPTO Track PPTO Hook-Up Box Metal Cover with Clips Plastic Cover (Standard) PTDO Hook-Up Box PTDOHB24 PTDOHB120 Door or Frame Drill-Sizes Aluminum or Metal No drill required Self-Drilling Screw Standard Wood 3/16” (4.30 mm) Pilot hole required 1/4” - 20 machine Metal Drill: #7 (0.201” dia.) Tap: 1/4” - 20 screw Hollow 9/32” (7 mm) through; Metal 3/8” (9.5 mm) door face opposite to closer Sleeve nuts and Aluminum 3/8” (9.5 mm) through bolts Optional or Wood 9/32” (7 mm); Through-bolts and All 3/8” (9.5 mm) dia. x grommet-nuts 3/8” (9.5 mm) deep on door opposite to closer Fasteners PTO Hook-Up Box Smoke Detector P7705PTDO P7705PTO BC BC Standard 7705LAP 7705LAP-DA Smoke Detector Power Adjustment Nut * This cover is only available for PULL SIDE applications. For special applications a separate door and frame Use of an auxiliary door stop is always recommended. Unit must be mounted on interior of building in dry Use this instruction sheet for installation sequence and See NFPA70 for wiring requirements and NFPA72 for alarm NOTE: preparation template is packed with these instructions. closer adjustments only. Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. environment, maximum humidity of 95%. system requirements. 1 80-9377-0716-020 (04-14) 7705PTO/7705PTDO Series Hinge (Pull) Side Application Parts ASSA ABLOY 1 2 Mark and Drill Holes CL 1/2 (13) B A 3-5/8 (92) Solenoid wire coiled inside end of track 3/4 (19) 5 6-3/4 (171) (127) Right Hand Shown Co ve r Optional Installation Sequence 3 RH Door After installed, bend out tabs to secure. Dim. "B” PTO 31-1/16 (788) 32-1/8 (816) 34-11/16 (881) 35-3/4 (908) + Sweep C Preparation for Fasteners Dim. "A” LH Door Closer Valves Up 7/8 (22) Conduit hole for concealed wiring only 2-3/8 (60) Power Track PTDO Closer Valves Down - 1-1/4 (32) 1-7/16 (37) 19 (483) 4 Door or Frame Aluminum or Metal Wood (see Note) Fasteners Self-Drilling Screw 1/4”-20 machine screw Metal Drill Sizes No drill required 3-16” (4.3mm) Drill #7 (.201” dia) Tap 1/4”-20 Note: Wood doors/frames MUST have pilot hole when using Self-Drilling Screws. Latch - + 5 Pinion Flat F G See Page 4 for wiring instructions. B A I Position Backcheck + D H 2 Hold Open Angle 7 (Between 85° and 110° only) A B - Caution: Don't completely close cushion valve 1 Lock into hold-open 6 Cushion + ! E - D Use holes that align in arms 8 Closing Force Install closer per instructions with the proper pre-load applied to the arm then adjust spring power. The power adjustment will not work properly if the closer spring is not pre-loaded. Product shipped with closing force set at the middle of the power range. + Optional Cover 9 7700M _ 7700P C Open door to desired angle DO NOT use a power drill or driver to turn adjustment nut. This will damage closer and void warranty. Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 2 80-9377-0716-020 (04-14) P7705PTO/P7705PTDO Series Stop (Push) Side Application ASSA ABLOY 1 Parts Mark and Drill Holes CL 3-1/8 (79) 2 B A 12 (305) Solenoid wire coiled inside end of track 4 (102) 4 (102) 4-3/4 (121) Bottom of Frame Stop 4 5/16 1-1/8 (102) (8) (29) 2-5/8 (67) Used for 7788 Drop Plate 2-3/8 (60) 4-1/4 (108) Co ve r Optional Left Hand Shown 6-3/4 (171) Preparation for Fasteners Door or Frame Aluminum or Metal Wood (see Note) Fasteners Installation Sequence 3 Pinion Flat Closer Valves Down See Page 4 for wiring instructions. B Power Track Dim. "A” Dim. "B” PTO 30-9/16 (776) 31-11/16 (805) 34-3/16 (868) 35-5/16 (897) PTDO LH Door RH Door + Sweep Closer Valves Up 4 - Self-Drilling Screw 1/4”-20 machine screw No drill required 3-16” (4.3mm) Drill #7 (.201” dia) Tap 1/4”-20 Note: Wood doors/frames MUST have pilot hole when using Self-Drilling Screws. Latch - + 5 F Position Backcheck C + A D 2 G (Between 85° and 110° only) A Lock into B 6 Cushion + ! - Caution: Don't completely close cushion valve Closing Force Hold Open Angle hold-open Metal Drill Sizes E H 1 1/2 (13) 1-1/8 (29) hole for Conduit 1 (25) 19 (486) D Use holes that align in arms + C Open door to desired angle 8 Optional Cover Install closer per instructions with the proper pre-load applied to the arm then adjust spring power. The power adjustment will not work properly if 7700M the closer spring is not pre-loaded. Product shipped with closing force set at the middle of the power range. _ DO NOT use a power drill or driver to turn adjustment nut. This will damage closer and void warranty. Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 9 7700P 3 80-9377-0716-020 (04-14) PTO Support Unit Wiring Diagram (120VAC Input) PTO Support Unit Wiring Diagram (24VAC/DC Input) Input Power Earth (+) (-) 24VAC/DC Circuit Board Input Power 4-Pin Jumper 3 2 1 Earth (+) (-) 1 2 3 4 2-Pin Jumper Openings for surface wiring shown 120VAC Circuit Board 1 2 3 4 2-Pin Jumper Openings for surface or concealed wiring Header for Solenoid Connection SOL Fuse (PTO125V) 125V / 1/2A Terminal Strip for Power Input Connection Test Switch 4-Pin Jumper 3 2 1 SOL Fuse (PTO125V) 125V / 1/2A Terminal Strip for Power Input Connection (Do not use a 120VAC PTO unit when power is supplied from a PTDO unit)ASSA ABLOY Header for Solenoid Connection Test Switch ELECTRICAL DATA 120VAC For PTDO Models: Refer to Wiring Instructions No. 80-9342-0902-021 (01-09) for making wiring connections. 24VAC 24VDC Detector 132V Max 26.4V Max 26.4V Max 26.4V Max Voltage 120V 102V Min 24V 20.4V Min 24V 20.4V Min 24V 20.4V Min Current .036 Amps .059 Amps .074 Amps 0.034 Amps NOTES: Maximum wire size is 14AWG. All wiring and connections use standard wiring practice conforming with local wiring codes. Again, open door to the hold-open position. Depress “Test Switch” button on the hook-up board (accessible through cover)...door should close. If arm does not release, see previous step. IMPORTANT: Remove solenoid wire from end of track before installing track to frame. Do not pinch or crimp wire. Once track and hook-up box are installed, solenoid wire must be plugged into Header on circuit board shown above. Installation of Cover: Plastic Cover (7700P): Slide cover insert into the un-used cutout in cover. Install cover using screws provided. Metal Cover (7700M): Fasten cover to mounting clips with screws provided. After making all wiring connections: Turn power to unit “ON”. (On Master (PTDO) unit only, red LED should illuminate once every 15 sec.). Track’s hold open force is preset at the factory. Open door to hold-open position. Manually pull door out of hold-open and release...door should close. If arm does not release from hold-open, increase the releasing force by turning the screw accessible thru the end cap of the track using the 9/64” hex wrench provided. Copyright © 2009, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. ASSA ABLOY 3000 Highway 74 East • Monroe, NC 28112 Tel: (877)- 974-2255 • Fax: (800)-338-0965 www.nor tondoorcontrols.com 4 80-9377-0716-020 (04-14)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 4 Create Date : 2014:04:15 16:35:27-04:00 Modify Date : 2014:04:15 16:35:27-04:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : McNally;Tommy Creator : CorelDRAW X6 Title : Untitled-1EXIF Metadata provided by EXIF.tools