NuboMed Technology S3000 Mobile Medical Cart User Manual
Shenzhen NuboMed Technology Co., Ltd. Mobile Medical Cart Users Manual
User Manual
Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com NuboMed Mobile Medical Cart S3000 Series User Manual Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com 1.Introduction NuboMed Mobile Workstation was specifically designed for the Medical professionals; incorporated with embedded PC, wireless communication module, intelligent power management, and mobile management technology. It’s suitable for various of bedside working environments, whether it be outpatient, emergency room, surgical or ICU and inpatient areas. It makes mobile rounds, nursing, supervision, detection and monitoring a reality for the medical personnel. Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com Disclaimer: product can be customized, actual unit may vary in configuration. 2.Instruction a. Power On/Off Power On: To turn on the workstation, press and hold the power button for 2 sec. Power indicators will be lit and PC will be turned on; Power Off: To turn off the workstation, press and hold the power button for 2 sec. Power indicators will be shut off and PC will be shut off. Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com b. Intelligent Control/Display Panel If unit is without the optional hot swap-able battery, both indicator shows the remaining power of the main battery. Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com Note: When the red light turns on, please charge the unit. When red light disappears, it indicates the battery is over 7% charged. While charging, indicator lights will flicker. When charging completes, indicator lights will remain lit. When red light flickers, please charge immediately to prevent computer shut down. c. Cabinet and Accessories Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com Thecabinetbodywasmadeofaluminumalloy,whichisanti-abrasion,anti-rustandanti-corrosion. Handlesaresmoothandthedrawersareallequippedwithautoretractiontrack.Standardmodelcomeswith 4drawers.Consumablesuppliessuchassyringes,cottonswab,medicinescanbestoredinthe10cmheight drawers.Infusionpouches,largesizeitemscanbestoredinthe20cmheightdrawers.Alldrawerplacement andsizecanbecustomizedpercustomerrequest.Drawerscanbesecuredwiththelockingmechanismon theright. ActualAccessoriesshapeandsizecanbecustommadepercustomerrequest d. Lockable Caster Two front casters come with braking mechanism, press down to lock the caster, lift up to unlock. Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com e. Expandable Work Surface Push inwards slightly to pop out the extra work surface; Push inwards to lock the surface back in. f. Monitor Adjustment Positions of the LED Monitor can be adjusted up or down, 360 degrees and leans forwards or backward Height Adjustment: Press down or lift upwards to adjust height 360 degrees turn: turn left or right to adjust Inclines forward or backward Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com 3.Attentions Service Please do not tamper with the work station by unscrew and open up the enclosure in any way without the specific instruction and authorization by NuboMed personnel. Only authorized and trained NuboMed service personnel are to repair the unit. Electrical Shock Warning NuboMed workstation is an electrical computer equipment with the potential of creating hazardous electrical shock to human. Please do not tamper with product without proper NuboMed authorization. Please do NOT operate the unit in or close to any liquid If the workstation is doused with any liquid, please unplug or shut down the unit immediately and do NOT turn back on until dry. Initial Start Up Mode Please charge continuously for 24 hours before first time usage to ensure the maximum output and extend the life of the battery. Storage Please keep the workstation in a well ventilated, dry, room temperature area without any corrosive substance nearby. Do Not store lying down, upside down or on top of one another. If the unit are to be sitting idle without usage for an extended periods of time, please disconnect the unit from any power source, do not keep it on charge mode. Please also ensure to recharge every month to prevent the battery from damage. Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com 4.Troubleshoot Symptom Analysis System won’t turn on System was not used for extended periods of time, battery is locked into dormant mode Power plug was not plugged in properly or was not plugged into a 220V wall plug LED monitor might be turned off, or either one of the power/HDMI/VGA/DVI cables are not properly connected System files damaged or lost System won’t charge System turned on but shows a black screen or without signals Computer won’t boot into the operating system Won’t connect to the wireless network Possible Virus issues Problem with the wireless network Wifi Network Card was off Wifi password was incorrect Unit height cannot be adjusted Workstation won’t stay put in place Network requires a fixed MAC address or allocate an IP Height adjustment function was locked Caster lock was not used If problem persists, Please contact your IT personnel or NuboMed service personnel 5. Packing List Name Mobile Workstation and accessories LED Monitor and cables User Manual Product Inspection and Warranty Certificate Tools Quantity 1 unit 1 set 1 copy 1 copy 1 set Solution Charge the unit for 24 hours and try again Unplug the connector or try a different 220V wall plug Turn the LED on by pressing the power button / reconnect all the cables Please contact your IT personnel to reload the system and or install anti-virus software Please contact your IT personnel to reset or repair the wireless network Turn back on the wireless network hardware Please contact your IT personnel to confirm the password Please contact your IT personnel Power lift: please follow the instruction to disable the accidental touch feature by touching the unlock button Manual Lift: make sure the adjustment handle was pulled upwards before lifting or pushing downwards Push down the caster lock to activate Shenzhen NuboMed Technology Co., Ltd. Tangtou1stRd.,SkyworthInnovationValley#5, BuildingC,6F,Shiyan,Baoan, Shenzhen Tel:755-33079022Fax:0755-36693461Ext806 www.nubomed.com FCC Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Shenzhen NuboMed Technology Co., Ltd. (Trademark) www.nubomed.com Official Wechat Channel: Nubomed Service Hot Line: 0755-33079022
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Administrator Create Date : 2018:07:24 11:50:49+08:00 Modify Date : 2018:07:24 11:50:49+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : Administrator Title : <4D6963726F736F667420576F7264202D20C5B5B2A9D2C6B6AFB9A4D7F7D5BE5334303030CAB9D3C3CBB5C3F7CAE928D3A2CEC4456E6729> Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.3.2 (Windows) Document ID : uuid:410aabcc-19dd-4566-897f-be2b397ead1c Instance ID : uuid:5cf93982-d149-4fcc-b7f9-c40b3be69df8 Page Count : 10EXIF Metadata provided by EXIF.tools