OKIN Refined Electric Technology RF31 Remote Control User Manual RF31 UserManual

OKIN Refined Electric Technology Co., Ltd. Remote Control RF31 UserManual

Users Manual

Download: OKIN Refined Electric Technology RF31 Remote Control User Manual RF31 UserManual
Mirror Download [FCC.gov]OKIN Refined Electric Technology RF31 Remote Control User Manual RF31 UserManual
Document ID3597474
Application ID4cWXEH7AODk+6Fl6o9nfIw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.8kB (397487 bits)
Date Submitted2017-10-10 00:00:00
Date Available2017-10-10 00:00:00
Creation Date2017-09-25 09:17:37
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2017-10-10 11:33:11
Document TitleMicrosoft Word - RF31_UserManual
Document CreatorPScript5.dll Version 5.2.2
Document Author: baclsh67

Issue department:Bedding Division
ProductFunction
instruction
Date:
Author:
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 1 of 8
RF.31.18.01
RF.31.18.01 Function instruction
1. Electrical configuration diagram:
CB.13.22.01
Issue department:Bedding Division
ProductFunction
instruction
Date:
Author:
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 2 of 8
RF.31.18.01
2. Function Picture
Issue department:Bedding Division
ProductFunction
instruction
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 3 of 8
RF.31.18.01
1.
Date:
Author:
Process of test
A.
HEAD UP button:Press and hold the button, the Head actuatorwill go up. Stop
when released.
B.
HEAD DN button:Press and hold the button, the Head actuator will go down.
Stop when released.
C.
FOOT UP button:Press and hold the button, the Foot actuator will go up. Stop
when released.
D.
FOOT DN button:Press and hold the button, the Foot actuator will go down. Stop
when released.
E.
HEAD & FOOT UP button:Press and hold the button, the Head and Foot actuator
will simultaneously go up. Stop when released.
F.
HEAD & FOOT DN button:Press and hold the button, the Head and Foot actuator
will simultaneously go down. Stop when released.
G.
ZERO GRAVITY button: Click the button, the Head and Foot actuator will start up
and keep running until arriving to the zero gravity position. Running can be stopped by
clicking any button.
H.
ANTI SNORE button: Click the button, the Head and Foot actuator will start up
and keep running until arriving to the ANTI SNORE position. Running can be stopped by
clicking any button.
Issue department:Bedding Division
ProductFunction
instruction
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 4 of 8
RF.31.18.01
I.
Date:
Author:
FLAT button: Click the button, the Head and Foot actuator will start up and keep
running until arriving to the FLAT position. Running can be stopped by clicking any
button.
J.
MEMORY A button: Click the button, the Head and Foot actuator will start up and
keep running until arriving to the Memory A position preset by user. Running can be
stopped by clicking any button.
K.
MEMORY B button: Click the button, the Head and Foot actuator will start up and
keep running until arriving to the Memory B position preset by user. Running can be
stopped by clicking any button.
The blue LEDs for backlight are on as long as any button is pressed. IF all buttons are
released the LEDs will automatically turn off three seconds later.
The blue LED for power is always on as long as the power on.
The
The
The
The
below positions can be changed or set by the end user.
Zero gravity position;
Memory A position;
Memory B position;
The procedure to set these special positions is below:
Step 1: Click the
button to flat the bed;
Step 2: Adjust the Head and Foot position to a desired position by pressing the
button HEAD_ UP or HEAD_DOWN or FOOT_UP or FOOT_DOWN;
Issue department:Bedding Division
ProductFunction
instruction
Step 4: Release the
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 5 of 8
RF.31.18.01
Step 3: Press and hold the
Date:
Author:
button for 3sec, backlight LED start flashing;
button then click one of
or
or
button before LED stop flashing. Then the Flashing stops immediately to
indicate the corresponding operating has completed successfully.
ALL of the Zero gravity position and the Memory A position and the Memory A
position can be restored to default sets by pressing and holding the
button for approximate six seconds until the backlight LEDs finally stop flashing
from first flashing.
L.
FLASHLIGHT button:Click the button, the Flashlight on the remote control will
turn on if it is being off or turn off if it is being on. If the Flashlight is turning on as the
button pressed, it will keep on as long as the button pressed. When the button is released,
the Flashlight will still keep on for several seconds then turn off with the backlight turning
off together.
M.
UNDERLIGHT button:Click the button, the Under-light under the bed will turn
on if it is being off or turn off if it is being on. If the Under-light is turning on as the button
pressed, it will keep on for 5 minutes then turn off automatically if the button isn’t
pressed again.
N.
Vibration INTENSITY ICREASEMENT button:
Click the button the vibrating intensity will raise up one level, total 3levels.
O.
Vibration INTENSITY DECREASEMENT button:
Issue department:Bedding Division
ProductFunction
instruction
Date:
Author:
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 6 of 8
RF.31.18.01
Click the button the vibrating intensity will lower down one level, total 3 levels.
The number of level represents the vibrating intensity. More big number of the level,
more strongly vibrating it is. The strongest vibrating is level 3, and the weakest is level
1.
Implement adjustment of the vibrating intensity is the way known as “PWM”.
Different vibration of PWM makes different intensity. The value of the vibration
corresponding to the level is below:
vibration
Level
20%
35%
50%
P.
Vibration SPEED INCREASEMENT button:
If the vibrating has started up, click the button, the vibrating speed will raise up one
level, total 4 levels.
Q.
Vibration SPEED DECREASEMENT button:
If the vibrating has started up, click the button, the vibrating speed will lower down
one level, total 4 levels.
The “Speed” essentially represents the vibrating mode. The mode in speed level 0~2 is
that the motor vibrates at intervals and the mode in speed level 3 does continuously.
The intervals and the corresponding level are below:
ON time
OFF time
Level
500mS
500mS
350mS
350mS
200mS
200mS
Continuous
Note:
ON time-----On vibrating
Issue department:Bedding Division
ProductFunction
instruction
Date:
Author:
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 7 of 8
RF.31.18.01
OFF time-----Stop vibrating
PS: If the vibrator has stopped, press any one of the four buttons of
, the vibrator will start up in the intensity of level one and in the previous speed.
R.
Vibration time button:
Press the button and released to stop all moves(including the actuators and vibrator) and
change circularly the vibrating time of the vibrator by one level once, total 3 levels。
The time means that vibrating keeps on for this period then automatically stops if no
any button related to vibrating is pressed again. The time and the LED indication are
below:
This LED flash a time, the vibrating time is 10minutes;
This LED flash a time, the vibrating time is 20minutes;
This LED flash a time, the vibrating time is 30minutes;
10min,20min,30min LED
Issue department:Bedding Division
ProductFunction
instruction
Date:
Author:
2017-09-21
Kyle
No:RF.31.18.01
Version:
1.1
Page 8 of 8
RF.31.18.01
FCC:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
ISED RSS Warning:
This device complies with Innovation,Science and Economic Development Canada licenceexempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radio
exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : baclsh67
Create Date                     : 2017:09:25 09:17:37+08:00
Modify Date                     : 2017:10:10 11:33:11-07:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : baclsh67
Title                           : Microsoft Word - RF31_UserManual
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:10:10 11:33:11-07:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:413fbde1-9070-4dd3-8387-77e14ca2ef91
Instance ID                     : uuid:7a9c756e-7809-4aa3-90e4-6ca376d9e6a0
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PCU-RF31

Navigation menu