OSANG Healthcare IGM-1001D Lipid profile and glucose measuring system for self testing User Manual 1

Infopia Co.,Ltd. Lipid profile and glucose measuring system for self testing 1

User Manual

   INFOPIA CO., LTD                                                                                    Page 1                                                                                              UM-M (Rev.0)  Operation Manual  Dear  IGM-1001D  Blood  Glucose  Monitoring  System Owner,  Thank  you  for  choosing  the  IGM-1001D  Blood  Glucose Monitoring  System.  This  manual  contains  everything  you need to know about your new glucometer and how it works. Please take a moment to read the instructions carefully.  We  understand  that  self-testing  of  blood  glucose  level provides  a way to control your diabetes and may  give  you peace of mind by testing regularly. As a result, IGM-1001D has been developed to provide you with a fast and accurate reading in a convenient and simple process. Our goal for the IGM-1001D Blood Glucose Monitoring System is to provide you  with  the  best  quality  healthcare  products  coupled  with superior  customer  service.  Always  consult  with  your healthcare professional, before making any changes to your diabetes  management.  The  IGM-1001D  Blood  Glucose Monitoring System is for in-vitro diagnostic use only.  Customer Service is available 24 hours a day, 7 days a week, and 365 days a year. Please call customer support center in your local area.   Important Information  The  IGM-1001D  Blood  Glucose  Monitoring  System  is intended  for  use  outside  the  body  (in-vitro  diagnostic  use only). It  should be used only for  testing blood  glucose and only with fresh capillary whole blood samples. It should not be used for the diagnosis of diabetes. Consult  with  your  physician  or  diabetic  healthcare professional about  daily management of  your  diabetes and proper use of the glucometer. Please  pay  close  attention  when  handling  blood.  Improper procedures may cause serious hazards to your health. The IGM-1001D Blood Glucose Monitoring System contains small parts, which could be a choking hazard for children if swallowed.   Test Principle IGM-1001D   blood glucose test strip is the bio-sensor which has  been  made  by  the  FAD-dependent  glucose dehydrogenase(enzyme).  FAD-GDH(enzyme)  quantitatively reacts with the glucose in the whole blood and the mediator. At this moment, mediator Fe(CN)63- is reduced to Fe(CN)64-. This  Fe(CN)64-  generated  by  the  reaction  is  re-oxidized  on carbon  electrode,  for  which  the  method  is  called amperometry.  The  measured  oxidation  current  exists  in proportion to the glucose concentration in the whole blood.             WARNING: 1.   All parts of the kit are considered bio-hazardous and can potentially  transmit  infectious  diseases,  even  after  you have taken cleaning and disinfection measures. 2. Always use a new, sterile lancet. Lancets are for single   use only. 3. Avoid getting hands lotions, oil, dirt or debris in and/or on the lancets and reusable lancing device. 4. Please refer to page 12 for cleaning and disinfecting IGM-1001D Blood Glucose Monitoring System. 5. Do not change your medication based on the IGM-1001D meter  test  results  without  contacting  your  physician  or healthcare professional first. 6. Do not assemble or disassemble the blood glucose     test meter 7. Keep out of direct sunlight.    CAUTION: Following list of IMPORTANT SAFETY INSTRUCTIONS provided: 1.  Close supervision is necessary when equipment is used by, on, or near children, handicapped persons or invalids. 2.  Do not place the equipment in liquid, nor put it where it could  fall  into  liquid.  If  the  equipment  becomes  wet, remove the batteries and dry the device. 3.  Use the equipment only for the purpose described in the instructions for use. 4.  Do  not  use  accessories  which  are  not  supplied  or recommended by the manufacturer. 5.  Do not place anything on top of the equipment.
   INFOPIA CO., LTD                                                                                    Page 2                                                                                              UM-M (Rev.0)              Learning the System  Intended use of Blood Glucose Test Meter The IGM-1001D Blood Glucose Monitoring System is intended  for  use  outside  the  body  only  (in-vitro diagnostic  use)  and  self-testing.  Recorded  results make  it  easier  for  your  doctor  to  access  your metabolic control. However, the self-testing should not take  the  place  of  overall  diabetes  management assessment  from  your  doctor.  It  should  be  used  for testing blood glucose (sugar) only with fresh capillary whole  blood  samples.  IGM-1001D  Blood  Glucose Monitoring  System is  intended  for  use in  places  like home  and  in  professional  setting  to  monitor  blood glucose levels.    CAUTION - Do not use system for any other purpose than blood   glucose test. - Cholesterol concentrations > 500 mg/dL or triglyceride   concentrations > 3,000 mg/dL may produce elevated   reading.   -  Icodextrin  does  not  interfere  with  this  version  of IGM-1001D test strips. - Do not use during or soon after xylose absorption   testing. Xylose in the blood will cause interference. -  Before  using  any  product,  please  read  all instructions. -  Consult  with  your  physician  or  diabetic  healthcare professional  about  daily  management  of  your diabetes  and  proper  use  of  the  glucometer.  If  you have any questions about the IGM-1001D product, please contact your local representative.   WARNING -  Before  using  IGM-1001D  system,  read  all instructions in this manual, and practice for accurate and  safe  test.  You  should  have  commentary recommendation  from  your  diabetes  care professional for the proper use of the meter and daily management of your diabetes. - If you think your blood glucose results are too low or too high, or if the results are doubtful, please contact your doctor.   - If your blood glucose result is unusually low or high, or you do not feel the result is correct, repeat the test again with a new test strip. -  If  the  results  are  still  inconsistent,  please  consult with  your  physician  before  making  any  decision  in controlling your diabetes.      Table of Contents Learning the System  Intended  use  of  blood  glucose  test meter IGM-1001D kit components   IGM-1001D meter IGM-1001D meter Display IGM-1001D test strip  --- 2 --- 3 --- 3 --- 3 --- 4 Before Testing:  Setting your meter Auto-coding function Performing a control solution test --- 4 --- 5 --- 5 Performing Your Test:  Testing Blood - preparation Performing  a  blood  test  with  your finger tip Test strip ejector function --- 6  --- 7 --- 9 Reviewing Your Results:  Reviewing your blood sugar Reviewing your averages  ---9 --10  Alternate Site Test:  Lancing  and  sampling  from  an alternate site area Lancing device clear cap is used for alternate site testing --10  --11 Caring for Your IGM-1001D System:  Cleaning your meter and maintenance Storage of your IGM-1001D system --12  --12 Transferring Your Result Data Download Application --12 --13 Battery Installation --13 Dispose of meter and batteries --13 Trouble-shooting --14 Warranty --15 Specifications --15 Symbol Reference --15
   INFOPIA CO., LTD                                                                                    Page 3                                                                                              UM-M (Rev.0)  IGM-1001D Kit Components    1. IGM-1001D Meter 2. IGM-1001D Test Strip 3. Reusable Lancing Device 4. Lancets   5. Operation Manual  6. Warranty Registration Card 7. Carrying Case 8. Patient Logbook 9. 2EA of 3V Coin   Battery (CR2032)  Your  IGM-1001D  Blood  Glucose  Monitoring  System  has been sealed to protect the contents. If you find your seal has been broken, please return it to the place of purchase.   IGM-1001D meter               <Front> Test Strip Port: Insert the IGM-1001D test strip  Display Screen: Displays  your  test  results, symbols and messages.  Power/Enter Button: Power the meter on/off, prompts memory  data  and  acts  as  an “Enter”  button  during setup and after tests.  Up/Down Arrow Buttons: Scroll  up  or  down  to  adjust settings or retrieve memory.       Test Strip Ejector: Releases and discards test strip  Serial Number:    Battery Cover:                     <Rear>            CAUTION 1.  Do  not  use  IGM-1001D  glucose  test  meter  in  a  dry environment, especially if synthetic materials are present. Synthetic  clothes,  carpets,  etc.,  may  cause  damaging static discharge in a dry environment. 2.  Do not use IGM-1001D glucose test meter near cellular or  cordless  telephones,  walkie-talkies,  garage  door openers, radio transmitters, or other electrical equipment that  are  sources  of  electromagnetic  radiation,  as  these may  interfere  with  the  proper  operation  of  the  glucose test meter.   IGM-1001D meter display    Low Battery Warning Symbol  Alarm Symbol  Troubleshooting Symbol  Delete Results  Average Test Result System  Before Having a Meal  After Having a Meal  After Taking Medication  After Sport Activity  Control Solution Symbol  Blood Drop Symbol for Test  Strip Code Symbol   Test Result Unit Symbol   Temperature / Date   Time / Test Result Amount  IGM-1001D test strip      Number Name Function 1 Entrance Blood goes into this area. 2 Air exit As blood enters, air exits thru this area 3 Confirmation Window Able to see through this window whether blood is fully filled. 4 Connector Connect between the electrodes and meter 5 Auto-coding label Automatic coding recognition
   INFOPIA CO., LTD                                                                                    Page 4                                                                                              UM-M (Rev.0)   CAUTION 1.  Store the IGM-1001D test strip vials in a cool, dry place. Keep out of direct sunlight. Do not freeze. 2.  Store test strips in their original vial only. Do not mix the test strips in new vials or in any other container. 3.  Immediately replace  the vial cap  and  close tightly  after removing any test strips from the vial. 4.  Make a note  of  the  expiry date,  which is three months from the date you first open a new vial of strips. Throw IGM-1001D test strips and vial away after the expiry date. 5.  Do not use the test strips after the expiration date printed on  the  package  or  vial,  since  it  may  cause  inaccurate results. 6.  IGM-1001D test  strips  should  be  single  use  only.  DO NOT RE-USE. 7.  Do not test at temperatures below 10℃(33.8°F) or above 40℃(104°F). 8.  Do not test in the condition that humidity is below 10% or above 90%. 9.  Do not bend, cut, or alter the test strip. 10. Avoid getting dirt, food, and water on the test strip with wet hands. 11. Avoid getting dirt, food, and water on the color-coding label (backside of test strip) 12. Refer to additional information in the IGM-1001D test strip package.          Before Testing  WARNING To reduce the chance of infection: 1.  Lancing device and lancets should NOT be shared with others. 2.  Always use a new lancet and a new blood glucose test strip. 3.  Practice  using  the  lancing  device  and  become accustomed with its use. 4.  Lancets and  blood glucose  test  strips  should  be  single use only. 5.  Wash  your  hands  in  warm  clean  running  water  using soap before testing. 6. Avoid  getting  hand  lotion,  oils,  dirt  or  debris  on  the lancets or on the lancing device. 7.  Dry your hands completely before testing.           Setting Your Meter  The  IGM-1001D  meter  has  a  wide  variety  of  functions  to choose from. From the setup mode you have the ability to turn  activity/meal  flags,  set  the  date/time,  designate  three unique averages and set up to five daily alarms.      Power On Press    for 3 seconds at least User Activity Option After pressing and releasing either ▲ or ▼ buttons to turn the User Activity Option on/off, confirm with  Year After pressing and releasing either▲ or ▼ buttons to set the year, confirm with         Date / Time After pressing and releasing either▲ or ▼ buttons to set the date and time, confirm each with   Number  of  days  for average After pressing and releasing either▲ or ▼ buttons to set the number of days for average calculation (3 different possible), confirm with   Alarm on/off After pressing and releasing either▲ or ▼ buttons to turn the alarm on/off, confirm with         Alarm time After pressing and releasing either ▲ or ▼ buttons to set the alarm hour and minute, confirm with  Alarm After programming the number of desired alarms (5 alarms possible), confirm with         CAUTION 1.  VERY IMPORTANT: Set the right test unit. Your IGM-1001D Meter is pre-set to mg/dL as test unit. A wrong  test  unit  will  read  to  wrong  test  result  display. Please consult your healthcare professional if you’re not sure  which  test  unit  to  use.  Without  setting  the  date properly,  the  average  glucose  level  and  the  results  in memory will not show proper values. It is recommended to set the glucose test meter before use and also when new batteries are installed. 2.  You cannot test your blood glucose in the setting mode. 3.  To  turn  the  meter  off  during  the  setup,  press    for  at least 3 seconds.
   INFOPIA CO., LTD                                                                                    Page 5                                                                                              UM-M (Rev.0)  Auto-coding Function   1.  IGM-1001D  has  automatic code  recognition  function(e.g. C26)         2. It recognizes the code number automatically.  This  is  a  very convenient  function  preventing the  inconvenience  of  setting  the code number on the glucose test meter every time. Check the code on  the  vial  to  see  if  the  codes match each other     CAUTION 1.  Do  not  bend  the  glucose  test  strip  to  prevent  the automatic code recognition failure. 2.  If  the  code  recognition  label  is  damaged,  code recognition may fail. Please check the code number on the LCD window together with the code number on the glucose test strip vial to see if code numbers match each other.      Backlight Function    When  inserting  IGM-1001D glucose  test  strip  (starting measuring  process),  backlight will turn on for 10 seconds.  After  the  test  result  displays, backlight will last for 10 seconds.    By  pressing  the  power  button (moving  into  memory  mode), backlight  will  turn  on  for  10 seconds.  When  pressing  the power  button for  3  seconds  (entering  the setting mode), backlight will turn on for 10 seconds.  When inserting the PC cable into the USB port, backlight will turn on for 10 seconds.         Performing a Control Solution Test  IGM-1001D  control  solutions  contain  a  known  amount  of glucose that reacts with IGM-1001D test strip. By comparing your  control  solution  test  results  with  the  expected  range printed on the test strip vial, it is able to check the meter and test strips are working properly and that you are performing the  test correctly.  It  is  very  important that  you  perform the check routinely to make sure you get accurate results.  The Glucose control solution should be used   Before using a new box of strips   Whenever you suspect the blood glucose test meter or blood glucose test strip is not functioning properly.   If your blood glucose test results are not consistent with your symptoms or if you think they are not accurate.   If you have dropped the blood glucose test meter.   For quality control in the point of care usage.   For teaching or learning the system.   When using the meter for blood glucose tests after any disinfection procedure.   Firmly insert the test strip into the meter test port. Insert down firmly in direction of arrow on test strip (arrow up). Please do not  insert  the  glucose  test  strip  upside down.   When you insert the glucose test strip into the glucose test meter, the power automatically adjusts the meter accordingly.      Before inserting blood, Scroll through the icons with the ▲ or ▼ button until the control solution bottle is blinking, press      1. Check  the  expiration  date  before performing a control solution test. Do not use if expired. Please note the  expiration  date  on  the  control solution bottle.    2. Gently  shake  the  control  solution before use.       3. Discard  the  1st  drop  of  control solution,  this  will  eliminate  any residue. Place a drop of control solution on a clean dry surface (e.g. the lid of the test strip vial)  26 IGM-1001D
   INFOPIA CO., LTD                                                                                    Page 6                                                                                              UM-M (Rev.0)      4. Dip  the  test  strip  into  the  control solution. Results will appear in 5 seconds. Compare  the  result  to  the  range printed  on  the  test  strip  vial,  the result should fall within that range  CAUTION 1. Control  solutions is  for in-vitro  diagnostic use  only.  This means that it is only used for testing outside the body. 2.  Control solution is  exclusively  made  for  the  IGM-1001D Blood Glucose Monitoring System. Do not use    other brand control solutions made by other manufacturers. 3.  Check  the  expiration  date  on  the  vial.  Do  not  use,  if expired. 4.  Once  opened,  use it  for  the  next  three  months  only. Record  the  discard  date  on  the  control  solution  bottle. Discard after three months.   5.  Do  not  swallow.  This  is  NOT  for  human  or  animal consumption. 6.  The  control solution  bottle icon contains letter  ‘C,’  so as not to be confused with the medication bottle.   This  will  allow  you  to  understand  differences  between  a control solution test and an actual blood test.   For example only : If you are using the normal control solution, according to this particular  vial of  strips,  your meter should  show a  number between 80 and 120.                                   Please note that the control values shown in the picture are not   control ranges.  NOTE: -  It is recommended that glucose control solution is stored at room temperature 20~25℃  (68~77℉) before testing. -  Check  the  expiration  date  before  performing  a  glucose  control solution test. -  Do not use if it expired. Once opened, the control solution expires after 3 months.  If your control solution test falls out of range, please follow the next steps before contacting customer support:   Check the expiration  dates  on  all the  products you are using. Be sure you are using IGM-1001D control solution.   Try another control solution test. If this test falls out of range, try another control solution test with a new unopened bottle of strips.   After following the appropriate steps and the control test still falls  out  of  range,  do  not  perform  a  glucose  test. Please call customer support toll: 82-31-460-0300  Follow-up Action 1.  Check  your  meter  and  strip  with  the  glucose  control solution. 2.  Perform your test again.  CAUTION 1.  If your glucose control solution falls out of range, do not perform  a  glucose  test  and  please  contact  your  local distributor. 2.  The glucose  control  solution’s measurement  range  has nothing to do with individual’s blood glucose level, as its own purpose is to check the status of strip and meter. Discard the used control solution and test strips carefully, according to the local regulation.              Performing Your Test  Testing Blood - Preparation Lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood.   Being  a  more  advanced  lancing  device,  it  provides ultimate safety and comfort for obtaining blood samples. An adjustable tip offers 5 different strength levels of skin penetration  for  individual  user’s  comfort,  while  a  lancet ejector enables the safe disposal of the used lancet. As an added bonus, this also comes with a transparent tip for AST (Alternative Site Testing).  CAUTION 1.  Never use a lancet that has been used by someone else. This could lead to contamination. 2.  If the lancing device is to be used by another person, the unit must use a new tip or properly disinfected 3.  Do not leave the lancet in the device after use. 4.  A  new  lancet  must  only  be  placed  into  the  lancing  device directly before testing. 5.  This  device  has  many  small  parts  and  could  be  a  choking hazard for children if swallowed. 6.  In  the  case  of  hospital  use,  hospitals  need  to  observe  their own  infection  control  protocols  in  order  to  avoid  any contamination. 7.  Always  dispose  of  the  used  lancet  in  a  biohazard  garbage container.         IGM-1001D IGM-1001D IGM-1001D IGM-1006 H. 255-345 N. 80-120 L. 35-65 IGM-1001D
   INFOPIA CO., LTD                                                                                    Page 7                                                                                              UM-M (Rev.0)   Components    Using the Clear Tip(AST) 1.  Place  the  lancing  device  and  lancet  on  the  skin  in  the chosen  area,  press  and  hold  it  continuously  for  a  few seconds,  then  push  the  release  button  to  take  a  blood sample. 2. Watch through the clear tip until a sufficient blood sample is  taken. If  there is not  enough blood, gently massage the area until a sufficient sample is collected.  STORAGE Products  must  be  stored  at  room  temperature  protected from sunlight or moisture.  CLEANING AND DISINFECTION -Clean  and  wipe  the  outer  part  of  lancing  device  once  a week at the minimum with a soft cloth dampened with mild soap and water. Wash the adjustable tip and clear tip, once a week with mild soap.   -DO NOT immerse the lancing device in water or liquid.  WARRANTY Lancing  device  has  a  2-year  warranty  from  the  date  of purchase. A malfunctioning device should be returned to the following address:  Manufacturer : GMMC Room  No.  1112,  Ace  Tower  9th  Bldg.,  345-30,  Gasan-dong, Geumcheon-gu, Seoul, South Korea Tel : +82 2 2104 0470 Fax : +82 2 2104 0472  EU Authorized Representative : GMMC, S.L. C/Vinalopo' 4 - 1° - Pta 4 Valencia, Spain Tel : +34 963 691 484 Fax: +34 961 125 949             Performing a blood test with your fingertip  Step 1  1.  Firmly  insert  the  test  strip  into  the meter  test  port.  Insert  down  firmly  in direction of arrow on test strip (arrow up). Please do not insert the glucose test strip upside down.   When you insert the glucose test strip into the glucose test meter, the power automatically turns on with the code and temperature.    2. Make sure the code number matches on the strip bottle its code (e.g. C26). The IGM-1001D automatically recognizes the test strip code number and adjusts the meter accordingly.     A blinking test strip will appear at the top of the screen indication the meter is ready for testing     CAUTION 1.  If  the  code  is  not  displayed  after  for  a  while,  pull  the glucose  test  strip  out  of  the  port,  and  re-start  the procedure from the beginning. 2.  If the code on the LCD display window as well as on the glucose test  strip vial  does  not  match,  try another  new glucose  test  strip.  If  the  mismatch  persists,  please contact your local representative for assistance. 3.  Avoid testing under direct sunlight, for a more accurate test result. 4.  If you apply your blood sample too early, Er5 message will appear on LCD. Please refer to Page 12.   Step 2 To obtain a suitable blood samples   Before  obtains  a  blood  sample,  wash  your  hands  with warm,  clean  water  and  soap.  Dry  hands  completely before testing.   WARNING 1.  All parts of the kit are considered bio hazardous and can potentially  transmit  infectious  disease,  even  after  you have conducted cleaning and disinfection measures. 2.  To  reduce  the  chances  of  getting  infection:  The  test strips are for single use only. Do not reuse. 3.  Avoid getting hands lotion, oil, dirt or debris in or on the lancets (single use only) and the lancing device. 4.  Wash your hands thoroughly with soap and clean water after handling the meter, lancing device and/or test strip.
   INFOPIA CO., LTD                                                                                    Page 8                                                                                              UM-M (Rev.0)   1. Unscrew the lancing   device cap.  2. Insert a sterile lancet into   the lancing device.  3. Twist the protective cover off. Do not discard.  4. Put the lancing cap back and twist it   tightly.  5. To adjust the depth setting: Use strength level 1-2 for soft  skin,  3  for  average skin,  4-5  for  thick  or calloused skin.   6. Pull the end of the   lancet device back.  7. To prick your finger,   push  the  center button.  CAUTION 1.  If  the  blood  smears  or  runs,  do  not  use  such  blood sample. Dry the area and gently squeeze another drop or puncture a new area of the finger. Do not share reusable lancing device with anyone               Step 3      IGM-1001D test meter only requires 0.5 ul sample volume.   Place the edge of the test strip to the drop of blood.  The blood will automatically be ‘drawn’ into the test strip channel.   When  your  sample  blood  is  enough,  your  meter  will automatically count down   CAUTION 1.  If the countdown does not start, do not add more blood to  the  glucose  test  strip.  Discard  the  glucose  test  strip and re-start testing. 2.  If  you  do  not  conduct  the  test  within  3  minutes,  the glucose  test  meter  will  automatically  power  off  to  save battery  life.  In  this  case,  test  procedure  should  start again from the beginning. 3.  You may get an inaccurate result if the blood sample is not completely filled. 4.    You must inject the blood sample until beep sounds.   Step 4      After the beeping sound, the test will begin automatically and your results will appear in 5 seconds. It should begin counting down  from 5 to  1  second on the LCD  display window. The LCD window will display the result of your blood glucose level. Temperature and time.   After  results  displayed,  you  choose  to  use  the activity/meal  flags  ( ),  press  and release  ▲  or  ▼  button  to  select  the  activity,  then press and release the power button
   INFOPIA CO., LTD                                                                                    Page 9                                                                                              UM-M (Rev.0)     Record the result value in your logbook. When glucose test  strip  is  removed,  the  glucose  test  meter  turns  off automatically.   CAUTION 1.  If the test result is out of the test range, “Hi/Lo” message will be shown on the LCD window. 2.  Safely discard used glucose test strips and lancets in the proper place, according to the local regulation.   Test Strip Ejector Function  Disposing of your test strip    Once  the  test  is  complete, push  the  strip  forward  to remove  the  test  strip  from the meter  Used  test  strips  may  be considered  bio  hazardous waste in your area. Be  sure  to  contact  your local  representative  for proper disposal  Disposing of your lancet   Push  the  needle  into  the protective cover.  Pull  the  lancet  out  and discard accordingly.      CAUTION 1. If you push the ejector button forward too much, it may be part of the failure. 2. Do not give strong impact to blood glucose test meter. 3. Please follow the waste disposal regulations on the used lancets and strips imposed by your local authorities.   Reviewing Your Results  The  IGM-1001D  meter  stores  up  to  365  test  results  in  its built-in memory,  along with the average sugar level for the number  of  days,  which  you  had  preset  the  glucose  test meter to calculate.   Reviewing Your blood sugar  Press and release    button.  The most recent result appears first. Note the time and day of your blood sugar result. Press and release the ▼ button and your previous result will appear on the display  Reviewing Your averages  Press and release the ▲ button and your average result will appear on the display.    Average Test Result    Test Unit  Test Result Amount  Average Test Result Days   Deleting Test Results   Deleting individual test result To  delete  any  individual  test  result  in  the memory press ▲ or ▼ button for 3 seconds, while  the  test  result  is  to  delete,  displayed   blinking. After the third beep sound you may hear, the test result is deleted.
   INFOPIA CO., LTD                                                                                    Page 10                                                                                              UM-M (Rev.0)   Deleting all test results To delete all test results in the memory press ▲ and ▼ button for 3 seconds, while the test result  is  to  delete,  displayed   blinking. After the third beep sound you may hear, the test results are deleted.  CAUTION The  deleted  test  results  cannot  be  recovered.  Please  be careful in deleting the test results.       Alternate Site Test   The  IGM-1001D  Blood  Glucose  Monitoring  System  gives you  the  ability  to  obtain  a  blood  sample  for  testing  your sugar from different areas of your body.   The figure shown above displays the areas where you can test using your IGM-1001D meter. You may test you blood sugar from your forearm, upper arm, palm (ventral palm or dorsal hand), fingertips, thigh, or calf.  IMPORTANT It is recommended that alternate site testing be used when sugars  are  stable:  before  meals  and  before  bedtime. However,  when  sugars  are  changing,  blood  from  the fingertip may show these changes sooner than blood from other sites.   LIMITATION 1.  Alternative site  testing  results should  never be  used to calibrate continuous glucose monitoring systems. 2.  Alternative  sampling  results  should  never  be  used  in insulin dosing calculations.       Lancing and sampling form an alternate site area  Sampling from your upper arm, forearm, dorsal hand, ventral palm, thigh, or calf allows you to use your fingertips less often. You may find that obtaining a blood sample from an alternate site is less painful than using a fingertip. Getting a blood sample from your forearm or palm is different than getting a sample from your fingertip.  Ventral palm/Dorsal hand  Choose  a  fleshy  area  on  the palm,  below  your  thumb  or pinky  finger.  Select  a  spot without  any  visible  veins  and away from any deep lines. This may  cause  your  blood  sample to smear.  Forearm Upper arm    Calf Thigh    Choose  a fleshy  area  of  the  forearm,  upper  arm, thigh,  or calf  away  from  bone, visible  veins  and/or  hair.  Sometimes there is less blood flow to these areas than to the fingertip. To  help  you  get  a  large  enough  drop  of  blood,  you  may gently  message  or  apply  a  heating  pad  to  the  site  to increase blood flow.  IMPORTANT We  recommend  that  you  test  on  your  fingertips  if  you  are testing  for  hypoglycemia  (low blood  glucose)  or  if  you  are suffering from hypoglycemia unawareness   To ensure accurate results when lancing your arm (forearm or  upper  arm), leg  (calf or thigh),  or palm (ventral palm  or dorsal hand), clean the test site with soap and water. Make  sure  there  is  no  cream  or  lotion  on  the  test  site. Thoroughly dry your hands and test site.  WARNING To  reduce  the  chances  of  getting  infection:  never  share  a lancet or reusable lancing device with anyone.
   INFOPIA CO., LTD                                                                                    Page 11                                                                                              UM-M (Rev.0)  The  lancing device  clear  cap is used  for  alternate site testing  Lance the test site with the lancing device  1. Remove  the  lancing  cap  by twisting off.    2. Insert  lancet  and  replace  with the clear cap.      3. To  bring  fresh  blood  to  the surface of the test site, rub the test  site  vigorously  for  a  few seconds  until  you  feel  it getting  warm.  Applying  heat may be helpful.    4. Adjust clear cap to the highest setting.  Hold  the  clear  cap down against a fleshy  area on the  alternative  site.  Press  the release button. Do not lift up.    5. Continue  to  hold  the  lancing device  and  gradually  increase pressure for several seconds.    6. While  holding  the  lancing device  on  your  test  site,  look through  the  clear  cap;  until  a round drop of blood appears      7. Lift the lancing device straight up; be careful not to smear the blood on your testing site.    8. Place the edge of the test strip to  the  drop  of  blood.  The blood  will  automatically  be drawn up.           REMEMBER 1. Consult  with  your  healthcare  professional  before  using alternate site testing. 2. Choose a different puncture site each time you test. Repeated punctures in the same spot may cause soreness and calluses. 3. If bruising  occurs  at  an  alternate  site  or  you  have  difficulty getting a sample, consider sampling from a fingertip instead. You  may  want  to  review  the  choice  of  sites  with  your healthcare professional. 4. Do  not  share  reusable  lancing device  with  anyone  including other family members.   CAUTION Do not test on you forearm or palm when 1. You  think  you blood  glucose  is  rapidly falling.  For example within two hours of exercise, rapid-action insulin injection, or an insulin pump bolus. 2. Testing with a fingertip sample may identify hypoglycemia or an insulin reaction sooner than testing with a forearm or palm sample.
   INFOPIA CO., LTD                                                                                    Page 12                                                                                              UM-M (Rev.0)  Caring for your IGM-1001D System  Cleaning your meter and maintenance    Blood glucose test meter : Your  blood  glucose  test  meter  does  not  require  special maintenance  or  cleaning.  Avoid  getting  dirt,  dust,  blood, glucose control solution, or liquids on the blood glucose test meter,  the  test  port,  or  data  port.  Your  blood  glucose  test meter’s operation  temperature is  10~40°C(50~104°F). It  is recommended that you store the blood glucose test meter in the portable pouch after each use. A  cloth  dampened  with  water  and  mild  detergent  can  be used to wipe down the outer part of the blood glucose test meter.  Your  IGM-1001D  blood  glucose  test  meter  is  a precision instrument. Please handle it with care.  Lancing device : Clean  the  lancing  device  and  caps  with  soap  and  tepid water. To disinfect the lancing device, prepare a disinfectant solution household bleach and water in 1(bleach) : 9(water) ratio. Dampen a cloth with this solution and wipe the lancing device thoroughly. Soak only the cap for at least 30 minutes in the disinfectant solution. Do not soak the lancing device in liquid. Rinse the lancing device and cap with water, and dry thoroughly. 1.  For  detailed  instructions  concerning  IGM-1001D  blood glucose  test  strips,  refer  to  the  blood  glucose  test  strip package inserted and found in the blood glucose test strip box. 2.  Please  store  the  IGM-1001D  blood  glucose  measuring system in a cool and dry area, out of reach of children. Do not freeze. For a more accurate test result, avoid testing under direct sunlight. 3.  Do  not  soak  the  blood  glucose  test  meter  or  blood glucose test strips in water or liquid. 4. Do not subject the meter or blood glucose test strips to excessive heat. 5.  Use  your  meter  according  to  the  instructions  in  the manual. 6.  If  you  need  to  purchase  the  lancing  device,  lancets  or blood glucose test strips, contact your local representative. 7.  Discard  the  used  lancets  carefully,  to  prevent  any infection.  Storage of your IGM-1001D System  To prevent the meter and test strips from getting dirt, dust or other  contaminants,  please  wash  and  dry  your  hands thoroughly before use  Meter Storage   Storage  condition:  10~40  ℃  or  50~104  ℉ (Temperature) / 10 ~ 90% (Humidity)   Always  store  and  transport  the  meter  in  its  original storage case.   Avoid dropping and strong impact.   Avoid direct sunlight and humidity.  Strip Storage   Storage condition: 2~30  ℃  or 36~86  ℉  (Temperature) / 10 ~ 90% (Humidity)   Store  your  test  strips  in  their  original  vial  only.  Do  not store the strips in other containers.   Store test strip packages in a cool and dry place. Keep away from direct sunlight and heat.   Do not freeze.   After  removing  a  test  strip  from  the  vial,  immediately close it tightly.   Record  the  discarded  date  (date  vial  opened,  plus  3 months) on the strip label.   Do not use if it is expired(2 years) after manufacturing.   Touch the test strip with clean and dry hands.   Do  not  use  if  3  months  have  been  passed,  since  the opening of the vial cap for strips.  Control Solution Storage   Storage condition: Store in a cool, dry place at between 8~30  ℃  or 46~86  ℉  (Temperature)   After use, close cap tightly.   Make sure the control solution bottle is tightly closed   Record  the  discarded  date  (date  vial  opened,  plus  3 months) on the control solution on the bottle.   Do not use if expiry date has passed.   It expires 24 months after manufacturing date.   It expires 3 months after opening the vial cap.  CAUTION 1. Store the IGM-1001D test strip vials in a cool, dry place. Keep out of direct sunlight. Do not freeze. 2. Store test strips in their original vial only. Do not mix the test strips in new vials or in any other container. 3.  Immediately  replace  the  vial  cap  and  close  tightly  after removing any test strips from the vial. 4. Make a note of the discard date, which  is three months from  the  date  you  first  open  a  new vial  of  strips.  Throw IGM-1001D test strips and vial away after the discard date. 5. Do not use the test strips after the expiration date printed on  the  package  or  vial,  since  it  may  cause  inaccurate results. 6. Do not test at temperatures below 10℃(50°F) or above 40℃(104°F). 7. Do not test with humidity below 10% or above 90%. 8. Do not bend, cut, or alter the test strip. 9. Avoid getting dirt, food, and water on the test strip with wet hands. 10. Avoid getting dirt, food, and water on the color-coding label (backside of test strip)
   INFOPIA CO., LTD                                                                                    Page 13                                                                                              UM-M (Rev.0)  Transferring your results  USE to Data Transfer CABLE(Option)  You can transfer test results from the IGM-1001D meter to a computer.  You  will  need  to  download  to  software  from  the  following web  site  (http://www.infopia21.com)  and  purchase  the computer cable from your local representative. This is sold separately.  USE to Bluetooth Unit  1.  Press  the  ‘Up’  button  of  the  IGM-1001  meter,  running pairing  mode. LCD  Screen  displayed ‘P’  and  start count from 0. 2. run to application on mobile phone. 3. Operating search mode on mobile phone. 4. select the operating meter in search list. 5. if pairing is succeeded, meter LCD screen displayed ‘P’ -> ‘C’ and re-start count from 0. 6. ‘Data Update’ command from the mobile phone to meter. 7.  Glucose  data  sent  from  meter  to  mobile  phone.  LCD screen displayed re-start count to 0. 8.  connection  termination  :  Press  ‘Power’  button  or application exit on mobile phone. 8. if connection is fail, LCD screen displayed ‘C’ -> ‘P’. After some seconds meter is power off automatically. 9. if pairing is incompleted, re-start to list 1.  Download application    Use apple app store or google play.  Battery Installation  The low battery icon   will appear in the upper left corner of  the  LCD display to  alert  you when  the battery  power  is running low, indication a new battery are needed.     Your IGM-1001D blood glucose test meter uses only two 3V lithium  batteries  (CR2032),  which  are  included.  When replacing  the  batteries,  only  CR2032  or  equivalent  lithium battery should be used.  Follow-up Action 1.  Check your meter with the glucose control solution 2.  Perform your test again. 3.  If you are experiencing symptoms that are not consistent with your blood glucose test results, call you healthcare professional.  NOTE: 1.  Make sure your date and time are correct after changing   your battery. 2.  Remove both batteries from the battery compartment and dispose of them, according to your institution's guidelines..    CAUTION 1.  Risk  of  explosion  if  battery  is  replaced  by  an  incorrect type. 2.  Dispose of used batteries according to the instructions.  Dispose of meter : The meter must be disposed of according to the local regulations concerning the disposal of electrical and electronic equipment. The Waste Electrical and Electronic Equipment(WEEE) regulation implement provisions of the European Parliament and Council Directive 2012/19/EU aimed to reducing the amount of EEE waste going for final disposal. The manufacturer,has specific instructions for the recovery of the meter. Please contact your distributor.  Dispose of batteries : Please recycle or dispose of used batteries using your local battery collection systems and in compliance with your local environmental laws and regulations. Batteries contain chemicals that, if released, may affect the environment and human health. The crossed-out wheeled-bin symbol indicates the need for the separate collection for batteries.
   INFOPIA CO., LTD                                                                                    Page 14                                                                                              UM-M (Rev.0)  Troubleshooting  The following chart may help you identify certain problems, but may not solve all problems that can occur. Contact your authorized  representative  or  Infopia  Co.,Ltd.  customer support if the problem persists.  Message What it means Action required  Problem with the blood glucose test meter Place the battery again, and set the blood glucose test meter. If the problem persists, Please contact your authorized representative or customer support.  Caused by either used or wet blood glucose test strip Please, insert a new glucose test strip and perform your test again  Problem with the test strip Please insert a new glucose test strip and apply the blood sample until confirming the window is completely filled.  Blood glucose test strip is damaged Please insert a new glucose test strip and perform your test again  User applied the blood sample before the LCD display  was blinking   Wait for the meter to display the blinking icon before applying your blood sample.  Color bar of the strip is dirty or not good or there is too much light. Action required.  Please insert a new glucose test strip and perform your test again. If blink with “Sun”, avoid to the direct sunlight and retest. Contact your local representative or customer support if the problem persists.  The ambient temperature is less than 10℃  (50℉) Place the meter at a temperature between 10 ~ 40℃  (50 ~ 104℉) for more than 10 minutes or more and test again.  The ambient temperature is over 40℃  (104℉) Place the meter at a temperature between 10 ~ 40℃  (50 ~ 104℉) for more than 10 minutes or more and test again.  The test result is lower than 10mg/dl Check the accuracy of your blood glucose test strip by Message What it means Action required  performing a glucose control solution test. If the test results in a normal reading, re-test your blood sample two or three times. If "Lo" persists, consult your doctor immediately.   The test result is higher than 700mg/dl Check the accuracy of your blood glucose test strip by performing a glucose control solution test. If the test results in a normal reading, re-test your blood sample two or three times. If "Hi" persists, consult your doctor immediately.  There are no reading stored in the meter -  Not enough reading in the memory to display designated average - The glucose test meter does not power its ON Battery is dead or there is a problem with the meter Change the battery and if the problem persists, contact your local representative. The glucose test meter does not start after applied blood sample. Insufficient amount of blood. Please insert a new test strip and perform your test again. The results are inconsistent There may be a problem with the glucose test strip Please insert a new test strip and perform your test again.
   INFOPIA CO., LTD                                                                                    Page 15                                                                                              UM-M (Rev.0)  Inconsistent or Unexpected Test Results  If  you  continue  to  get  unexpected  results,  check  your system  with  control  solution.  If  you  experience  symptoms that are not consistent with your glucose results, review and follow all instruction in this manual. Never ignore symptoms or make significant changes to you diabetes control program. Inform  health  care  professional  of  symptoms  and/or concerns.  CAUTION 1.  Low  Glucose  Results:  if  your  result  is  lower  than 70mg/dL, it may mean hypoglycemia (low blood sugar). This may require immediate treatment according to your healthcare profession’s recommendations. Although this result could be due to a test error, it is safer to treat first and you may test another. 2.  High  Glucose  Results:  if  your  test  result  is  higher  than 180  mg/dL,  it  may  mean  hyperglycemia  (high  blood sugar).  If  you  are  uncertain  about  your  test  results, consider  with  re-test.  Your  health  care  profession  will help you to decide how it action. If the meter displays HI all the time, please re-check your blood sugar but still it’s higher,  please  find  your  healthcare  profession immediately.   Warranty  Manufacturer’s Warranty Infopia  Co.,Ltd.  warrants  to  the  original  purchaser  that  this instrument will be free from defects in workmanship for 3 years from the date of original purchase.  Limitations of Warranty This  warranty  is  subject  to  the  following  exceptions  and limitations. 1. Infopia  Co.,Ltd.  shall  not  be  required  to  replace  any  units which  are  damaged  or  malfunction  due  to  abuse,  accidents, alteration,  neglect,  misuse,  maintenance  by  someone  other than Infopia Co.,Ltd. or failure to operate in accordance with the instructions. 2. Infopia Co.,Ltd. reserves the right to make changes in design without obligation to incorporate such changes into previously manufactured instruments. 3. Infopia Co.,Ltd. has no knowledge of the performance of the instrument  when  the  test  strip  is  altered  or  modified  in  any manner.  For Warranty Service Purchaser must contact the customer service department of Infopia Co.,Ltd.  by  calling  toll  82-31-460-0300,  for  assistance  and/or instructions for obtaining service of this instrument.  Service Information Infopia Co.,Ltd. has trained specialists to help you 24 hours a day, 7 days a week, and 365 days a year.  IMPORTANT Confirming  to  Infopia  Co.,Ltd.  representative  before  returning your  meter  for  any  reason.  You  will  be  given  the  information needed  to  get  your  problem  handled  correctly  and  efficiently. Remaining your meter, test strip and control solution nearby when you call. Declaration of Conformity  FCC  THIS  DEVICE  COMPLIES  WITH  PART  15  OF  THE  FCC RULES. Operation is subject to the following two conditions; (1) this device  may  not  cause  harmful  interference,  and  (2)  this device  must  accept  any  interference  received,  including interference that may cause undesired operation.   CAUTION Changes  or  modifications  not  expressly  approved  by  the party  responsible  for  compliance  could  void  the  user's authority to operate the equipment.   NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the  FCC  Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee  that  interference  will  not  occur  in  a  particular installation.  If  this  equipment  does  cause  harmful interference  to  radio  or  television  reception,  which  can  be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase  the  separation  between  the  equipment  and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the  dealer or  an  experienced radio/TV  technician for help.
   INFOPIA CO., LTD                                                                                    Page 16                                                                                              UM-M (Rev.0)  Specifications  Sample Type Capillary,  venous,  arterial  whole blood Sample Volume 0.5  ㎕ Test Range 10 ~ 600 mg/dL Reading Time 5 seconds Hematocrit 20 ~ 60% Altitude 3048 meter Up to (10,000 feet) Operating Temperature 10 ~ 40℃  (50 ~ 104℉) Operating Humidity 10 ~ 90% Strip Storage Temperature Store  2~30  ℃  or  36~86  ℉  and no direct sunlight. Do not Freeze Display Type LCD (Including backlight model) Dimension(HxDxT) 96 X 56 X 23.5 (mm) Weight 66±1g (Including batteries) Power Source 3V (Coin Battery, CR2032 X 2EA) Batter Life IGM-1001D: Running 1,000 Tests   Symbol Reference  Symbol Description  Consult Instructions for use  Use By date  This product fulfills the requirements of Directive 98/79/EC on in-vitro diagnostic medical devices  Attention, See Instructions for use  For in-vitro diagnostic use  Batch code  Do not reuse  Serial number  Date of Manufacture  Manufacturer  Keep away from sunlight  Waste electrical and electronic equipment symbol  Temperature limitation  Catalogue number  Self-testing used  Authorized representative in the European Community  Biohazard  Separate collection of batteries  Infopia Co., Ltd.  132, Anyangcheondong-ro, Dongan-gu, Anyang-si,   Gyeonggi-do, Korea www.infopia21.com  Obelis S.A Bd. Genaral Wahis 53, 1030 Brussels, BELGIUM Tel : +(32)2.732.59.54 Fax : +(32)2.732.60.03 E-Mail : mail@obelis.net    Rev. 2012-03  MEMO

Navigation menu