Ogemray Technology WFXM05 USB Wifi Adaptor User Manual

Shenzhen Ogemray Technology Co.,Ltd USB Wifi Adaptor

user manual

Download: Ogemray Technology WFXM05 USB Wifi Adaptor User Manual
Mirror Download [FCC.gov]Ogemray Technology WFXM05 USB Wifi Adaptor User Manual
Document ID1481225
Application IDeJYrN14IaxAOI7stXmgslQ==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize49.28kB (615988 bits)
Date Submitted2011-06-10 00:00:00
Date Available2011-06-10 00:00:00
Creation Date2011-01-25 09:29:18
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2011-01-24 17:57:25
Document TitleMicrosoft Word - user manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: zmp

Shenzhen Ogemray Technology Co., Ltd
IEEE 802.11 b/g/n WiFi Module
Product Specifications
Model: M05
Version: 1.3
2010-12-27
Information in this document is subject to change without prior notice.
Page 1 of 7
Shenzhen Ogemray Technology Co., Ltd
1. Introduction
GWF-M05 is a WLAN module supporting IEEE 802.11 b/g/n standards with 6-pin connector
supporting USB 2.0 interface. This is a low cost compact WLAN module designed in the product
with embedded system for the wireless connectivity.
1.1 Scope:
GWF-M05 WLAN Module is designed to operate in 2.4GHz ISM frequency band, it applies a
highly integrated MAC/BBP and RF single chip RT3070 with 150Mbps PHY rate supporting. It
fully complies with IEEE802.11n draft 3.0 and IEEE802.11b/g feature.
1.2 Features
802.11b: 1, 2, 5.5, 11Mbps;
802.11g: 6, 9, 12, 18,24, 36, 48, 54Mbps
802.11n:
(20MHz) MCS0-7, Support up to 72Mbps
(40MHz) MCS0-7, Support up to 150Mbps
OFDM, Peak rate 150Mbps, Peak throughput 90Mbps.
Security support for 64/128 WEP, WPA, WPA2, TKIP, AES
Operates in 2.4GHz frequency bands. Power Management
Antenna configuration: I-PEX receptacle for external antenna.
2. Product Information
2.1 Specification Overview
Standards
IEEE802.11b/g & 802.11n (1T1R mode)
Operating
Frequency
USA (FCC): 2.412GHz ~ 2.462GHz (channel 1 – 11) ISM band
Protocols
802.11b: CCK, QPSK, BPSK, 802.11g/n: OFDM
Antenna
External Antenna via an I-PEX receptacle
Security
WPA/WP2, 64/128/152-bit WEP, WPS
Transmit Output
Power (PK Power)
11b: 21±1.0dBm; 11g: 2016±1dBm
Receive Sensitivity
(Typical)
11b: -84dBm @ 11Mbps; 11g: -68dBm @ 54Mpbs.
Operating Voltage
5.0VDC ± 5% (or3.3VDV± 5% upon special requirement)
Operating Current
<110mA at 5.0V DC input.
Europe (CE): 2.412GHz ~ 2.472GHz (channel 1 – 13) ISM band
802.11n: (HT20), 20+/-1dBm,
802.11n: (HT40), 20+/-1dBm,
802.11n: (HT20), -66dBm@MSC7, (HT40),-62dBm@MSC7
Information in this document is subject to change without prior notice.
Page 2 of 7
Shenzhen Ogemray Technology Co., Ltd
Bus Interface
USB 2.0/USB1.1
USB Interface
6-pin, 2.0mm pitch male jumper , or 1.0mm pitch connector
Antenna Impedance 50 ohm
2.2 Hardware Information
GWF-M05 is low power consumption and low-cost compact WLAN module. This module can
be built-in other embedded applications such as IP Camera, IP set top box, GPS, Internet radio
apparatus.
2.2.1 Block Diagram
Figure 1: System Block Diagram of GWF-3M04 5.0V WLAN Module
Figure 2: System Block Diagram of GWF-3M04 3.3V WLAN Module
Information in this document is subject to change without prior notice.
Page 3 of 7
Shenzhen Ogemray Technology Co., Ltd
2.3 Software and system Information
Operation System
CPU Supplier
Driver
Linux 2.4/2.6
ARM, MIPSII
Available
Windows 2000/XP/Vista
X86 Platform
Available
Windows CE 5.0/6.0
ARM, MIPSII
Available
2.4 Mechanical Information
2.4.1 OUTLINE and USB Connection Information (40x18mm)
a). 6-pin 1.0 mm pitch connector.
b). 6-pin 2.0 mm pitch male jumper.
Information in this document is subject to change without prior notice.
Page 4 of 7
Shenzhen Ogemray Technology Co., Ltd
(To be noted: For special application, the direction of the male jumper can be upside
down mounted)
2.4.2 Pin definition:
Pin
6-pin 1.0mm pitch connector
6-pin 2.0mm pitch male jumper
VCC (3.3 VDC or 5.0VDC)
VCC (3.3 VDC or 5.0VDC)
UD-
( USB data-)
UD-
( USB data-)
UD+
(USB data+)
UD+
(USB data+)
GND (Ground)
GND (Ground)
LED
(Wireless TX status)
TX
TX
(RF ON/OFF control)
LED
(RF ON/OFF control)
(Wireless TX status)
*The TX ( RF ON/OFF control) is low level activated to OFF.
2.4.3 Antenna Connection Information
An external antenna via an I-PEX receptacle.
2.5 Order information:
Information in this document is subject to change without prior notice.
Page 5 of 7
Shenzhen Ogemray Technology Co., Ltd
GWF-3M05-33-T, for 3.3+/-5%VDC, the long pins are at the same side with the shield case.
GWF-3M05-33-B, for 3.3+/-5%VDC, the long pins are at the opposite side with the shield case.
GWF-3M05-33-C, for 3.3+/-5%VDC, Soldered with 6 pin connector.
GWF-3M05-50-T, for 5.0+/-5%VDC, the long pins are at the same side with the shield case.
GWF-3M05-50-B, for 5.0+/-5%VDC, the long pins are at the opposite side with the shield case.
GWF-3M05-50-C, for 5.0+/-5%VDC, Soldered with 6 pin connector.
3. Agency Approval
Agency
Approval
FCC Part15
undergoing
CE
√
RoHS
√
4. Environment
4.1 Temperature
4.1.1 Operating Temperature
Continuous reliable operation in ambient temperature: 0ºC to +50ºC.
4.1.2 Storage Temperature
The product is not damaged or degraded when keeping in -20ºC to +85ºC.
4.2 Humidity
4.2.1 Operating Humidity Conditions
The product is capable of continuous reliable operation when subjected to relative humidity
in the range of 20% to 80% (non-condensing).
4.2.2 Non-Operating Humidity Conditions (including warehouse)
The product is not damaged or degraded when kept in the relative humidity range
from 20% to 80%.
5 Disclaimer
THESE MATERIALS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED , INCLUDING BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
Information in this document is subject to change without prior notice.
Page 6 of 7
Shenzhen Ogemray Technology Co., Ltd
PARTICULAR PURPOSE OR NON-INFRINGEMENT.
We uses reasonable efforts to include accurate and up-to-date information on this document;
it does not, however, make any representations as to its accuracy or completeness of the
information, text, graphics, links or other items contained within these materials. Your use of
this Document is at your own risk. Ogemray, its suppliers, and other parties involved in creating
and delivering this Document’s contents shall not be liable for any special, indirect, incidental,
or consequential damages, including without limitation, lost revenues or lost profits.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator & end User's body.
Information in this document is subject to change without prior notice.
Page 7 of 7

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2011:01:24 17:57:25-08:00
Create Date                     : 2011:01:25 09:29:18+08:00
Metadata Date                   : 2011:01:24 17:57:25-08:00
Format                          : application/pdf
Title                           : Microsoft Word - user manual.doc
Creator                         : zmp
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:6cc61963-a5d3-4df7-8434-4d63edf88233
Instance ID                     : uuid:b1c08b5e-7e61-4949-b4ac-c1b6b56a490b
Page Count                      : 7
Author                          : zmp
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YWTWFXM05

Navigation menu