Olympus Medical Systems RU5808 WIRELESS RECEIVER User Manual XGT8045 0001 fm10

Olympus Medical Systems Corp. WIRELESS RECEIVER XGT8045 0001 fm10

User Manual

INSTRUCTIONSWIRELESS TRANSMITTERUWIT-Y0001-TXWIRELESS RECEIVERUWIT-Y0001-RXLabels and Symbols 1Important Information — Please Read Before Use 4Chapter 1 Checking the Package Contents 11Chapter 2 Nomenclature and Functions 15Chapter 3 Installation and Connection 21Chapter 4 Inspection 31Chapter 5 Operation 35Chapter 6 Care, Storage, and Disposal 37Chapter 7 Troubleshooting 39Appendix 43USA: CAUTION: Federal law restricts this device to sale by or on the order of a physician.OPERATION MANUAL
ContentsiUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALContentsLabels and Symbols ..........................................................................................................  1Important Information — Please Read Before Use .........................................................  4Intended use ..........................................................................................................................  4Instruction manual  .................................................................................................................  4User qualifications  .................................................................................................................  5Instrument compatibility .........................................................................................................  5Repair and modification .........................................................................................................  5Signal words  ..........................................................................................................................  6Dangers, warnings, and cautions  ..........................................................................................  6EMC (Electromagnetic Compatibility) ..............................................................................  8Summary of Equipment Functions  ..................................................................................  9Transmitting function of HDTV video signal over radio frequency channel  ...........................  9Pair changing function  ...........................................................................................................  9Chapter 1 Checking the Package Contents  ....................................... 111.1 Checking the package contents ............................................................................  11Chapter 2 Nomenclature and Functions  ............................................ 152.1 Symbols and descriptions .....................................................................................  152.2 Front panel of Wireless Transmitter  .....................................................................  162.3 Rear panel of Wireless Transmitter  ......................................................................  172.4 Front panel of Wireless Receiver ..........................................................................  182.5 Rear panel of Wireless Receiver  ...........................................................................  182.6 AC adapter  ..............................................................................................................  19Chapter 3 Installation and Connection ............................................... 213.1 Precautions for installation and connection ........................................................  213.2 Installation of the equipment .................................................................................  223.3 Installation of the AC adaptor  ...............................................................................  24Installation on the Attachment for UWIT (MAJ-Y0149) ........................................................  243.4 Connecting AC adaptor to Wireless Transmitter or Receiver  ............................  253.5 Connecting AC adaptor to an AC mains power supply ......................................  26When using the power cord of mobile workstation (WM-NP1, WM-WP1, WM-DP1)  ..........  26When using the supplied AC cord  .......................................................................................  263.6 Connecting video cables to Wireless Transmitter  ..............................................  27Selection of video input terminal ..........................................................................................  27Connection diagram (When using HD-SDI) .........................................................................  28Connection diagram (When using DVI)  ...............................................................................  29
iiContentsUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL3.7 Connecting video cables to Wireless Receiver  ................................................... 30Connection diagram  ............................................................................................................  30Chapter 4 Inspection ............................................................................ 314.1 Inspection of the power supply ............................................................................. 314.2 Inspection of the displayed image ........................................................................ 32Chapter 5 Operation ............................................................................. 355.1 Turn the Wireless Transmitter and Receiver ON  ................................................. 35When the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is used ..............................  35When the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is not used  ........................  355.2 Connection of the Wireless Transmitter and Receiver  ....................................... 36Chapter 6 Care, Storage, and Disposal  .............................................. 376.1 Care .......................................................................................................................... 376.2 Storage .................................................................................................................... 386.3 Disposal ................................................................................................................... 38Chapter 7 Troubleshooting .................................................................. 397.1 Troubleshooting ..................................................................................................... 397.2 Troubleshooting guide ........................................................................................... 407.3 Returning the Wireless Image Transmitter Unit for repair .................................. 42Appendix ................................................................................................. 43Combination equipment .................................................................................................. 43System chart ........................................................................................................................  43FCC (for Wireless Transmitter and Receiver) ................................................................ 45FCC/IC (for Wireless Transmitter and Receiver)  ........................................................... 45Specifications ................................................................................................................... 46Environment ........................................................................................................................  46Specifications .......................................................................................................................  48EMC information  .............................................................................................................. 50FCC WARNING  ................................................................................................................. 54
Labels and Symbols1UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALSafety-related labels and symbols are attached on the locations shown below. If labels or symbols are missing or illegible, contact Olympus.Wireless TransmitterLabels and SymbolsSerial number plateThis instrument emits RF (Radio Frequency) energy to perform intended functions.Manufacturer namePotential equalization terminalCSA/UL markingElectric ratingThe product name, rated voltage, and notice for AC adapter are shownWIRELESS TRANSMITTERMODEL              :UWIT-Y0001-TXPOWER INPUT   : 12 V 1 AFor use with power supply OLP-K027-MFCC noteFCC ID numberIC number
2Labels and SymbolsUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALWireless ReceiverAC AdaptorSerial number plateManufacturer namePotential equalization terminalCSA/UL markingElectric ratingThe product name, rated voltage, and notice for AC adapter are shownWIRELESS RECEIVERMODEL              :UWIT-Y0001-RXPOWER INPUT   : 12 V 0.8 AFor use with power supply OLP-K027-MFCC noteFCC ID numberIC numberThis instrument emits RF (Radio Frequency) energy to perform intended functions.OLYMPUSAC AdapterModel Name: OLP-K027-MINPUT            : 100–240 V 1–0.5 A, 50/60 HzOUTPUT        :         12 V 1.3 AManufacturer nameElectric ratingThe product name, rated voltage, and notice for AC adapter are shown
Labels and Symbols3UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALBack cover of this instruction manualSymbol DescriptionManufacturerAuthorized representative in the European Community
4Important Information — Please Read Before UseUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALIntended useThe Olympus Wireless Image Transmitter Unit UWIT-Y0001 is a paired transmitter and receiver, intended for delivery of video signals over a radio-frequency link to a video display during endoscopic and general surgical procedures. The Olympus UWIT-Y0001 is a non-sterile reusable device not intended for use in the sterile field. It is intended for use by qualified physicians having complete knowledge of these surgical procedures.Instruction manualThis instruction manual contains essential information on using this Wireless Image Transmitter Unit safely and effectively. Before use, thoroughly review this manual and the manuals of all equipment which will be used during the procedure and use the equipment as instructed.Keep this and all related instruction manuals in a safe, accessible location. If you have any questions or comments about any information in this manual, please contact Olympus.Terms used in this manualVideo system center:The video system center is a device that converts signals from a videoscope or video converter, camera head into monitor images.Wall mains outlet:The wall mains outlet is a wall AC mains power outlet socket having the exclusive terminal for grounding.Important Information — Please Read Before Use
Important Information — Please Read Before Use5UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALUser qualificationsIf there is an official standard on user qualifications to perform endoscopy and endoscopic treatment that is defined by the medical administration or other official institutions, such as academic societies on endoscopy, follow that standard. If there is no official qualification standard, the operator of this instrument must be a physician approved by the medical safety manager of the hospital or person in charge of the department (department of internal medicine, etc.). The physician should be capable of safely performing the planned endoscopy and endoscopic treatment following guidelines set by the academic societies on endoscopy, etc., and considering the difficulty of endoscopy and endoscopic treatment. This manual does not explain or discuss endoscopic procedures.Instrument compatibilityRefer to the “System chart” on page 43 to confirm that this Wireless Image Transmitter Unit is compatible with the ancillary equipment being used. Using incompatible equipment can result in patient injury or equipment damage and makes it impossible to obtain the expected functionality.This instrument complies with the EMC standard for medical electrical equipment; edition 3 (IEC 60601-1-2: 2007), edition 2 (IEC 60601-1-2: 2001). However, when connected with an instrument that complies with the EMC standard for medical electrical equipment; edition 1 (IEC 60601-1-2: 1993), the whole system complies with edition 1.Repair and modificationThis Wireless Image Transmitter Unit does not contain any user-serviceable parts. Do not disassemble, modify or attempt to repair it; patient or operator injury, equipment damage and/or the impossibility to obtain the expected functionality can result. Some problems that appear to be malfunctions may be correctable by referring to Chapter 7, “Troubleshooting”. If the problem cannot be resolved using the information in Chapter 7, contact Olympus. This instrument is to be repaired by Olympus technicians only.Change or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
6Important Information — Please Read Before UseUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALSignal wordsThe following signal words are used throughout this manual:Dangers, warnings, and cautionsFollow the dangers, warnings and cautions given below when handling this Wireless Image Transmitter Unit. This information is to be supplemented by the dangers, warnings, and cautions given in each chapter.DANGER• Strictly observe the following precautions. Failure to do so may place the patient and medical personnel in danger of electric shock.Keep fluids away from all electrical equipment. If fluids are spilled on or into the unit, stop operation of the Wireless Image Transmitter Unit immediately and contact Olympus.Do not prepare, inspect or use this Wireless Image Transmitter Unit with wet hands.• Never install and operate the Wireless Image Transmitter Unit in locations where:The concentration of oxygen is high;Oxidizing agents (such as nitrous oxide (N2O)) are present in the atmosphere;Flammable gases are present in the atmosphere;Flammable liquids are near.Otherwise, explosion or fire may result because this Wireless Image Transmitter Unit is not explosion-proof.Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices or potential equipment damage.Indicates additional helpful information.DANGERWARNINGCAUTIONNOTE
Important Information — Please Read Before Use7UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALWARNING• In case of Wireless Image Transmitter Unit failure or malfunction, always keep another Wireless Image Transmitter Unit in the room ready for use.• Only use the supplied AC adaptor. Do not use the supplied AC adaptor to power other devices. The equipment may fail or the power cord may burn.• Always use the power cord and connection cables that were shipped with the monitor or mobile workstation. Using other power cords or connection cables may result in an electric shock or malfunction.CAUTION• Do not use a pointed or hard object to press the buttons on the front panel. This may damage the buttons.• Do not touch the electrical contacts inside the Wireless Image Transmitter Unit’s connectors.• Do not apply excessive force to this Wireless Image Transmitter Unit and/or other instruments connected. Otherwise, damage and/or malfunction can occur.
8EMC (Electromagnetic Compatibility)UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL• In order to provide the intended functionality (HDTV image transmission), the Wireless Image Transmitter Unit (UWIT-Y0001) emits RF (Radio Frequency) energy while in operation. This may affect electrical devices in the vicinity.• The Wireless Image Transmitter Unit (UWIT-Y0001) utilizes RF signals shown below. Accordingly, it is subject to electromagnetic interference from other in-band equipment in the vicinity.EMC (Electromagnetic Compatibility)Central Frequency 60.48 GHz (When using CH1)62.64 GHz (When using CH2)Frequency range of possible interference59.40 – 61.56 GHz (When using CH1)61.56 – 63.72 GHz (When using CH2)Modulation method OFDMHigh-frequency outputLess than +40 dBm
Summary of Equipment Functions9UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALThis Wireless Image Transmitter Unit transmit HDTV video signal over radio frequency channel with no compression and low latency between a pair of transmitter and receiver. This instrument supports functions below.Transmitting function of HDTV video signal over radio frequency channel• When using the HD-SDI input connector for the Wireless TransmitterA paired Wireless Transmitter and Receiver can transmit 1080i (60/50 Hz) digital HDTV video signal over radio frequency channel• When using the DVI input connector for the Wireless ReceiverA paired Wireless Transmitter and Receiver can transmit 1080p (60/50 Hz) digital HDTV video signal and SXGA: 1280 × 1024 (60 Hz) digital video signal over radio frequency channelPair changing functionBy using the SELECT button of the Wireless Transmitter and Receiver, the Channel (CH1 or CH2) for pairing Transmitter and Receiver can be set manually.oSee Section 5.2, “Connection of the Wireless Transmitter and Receiver”.Summary of Equipment Functions
10Summary of Equipment FunctionsUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
1.1 Checking the package contents11UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.1Chapter 1 Checking the Package ContentsMatch all items in the package with the components shown below. Inspect each item for damage. If the Wireless Image Transmitter Unit is damaged, a component is missing, or you have any questions, do not use the Wireless Image Transmitter Unit; immediately contact Olympus.Wireless Transmitter1.1 Checking the package contentsWireless Transmitter (UWIT-Y0001-TX)AC adaptor AC cord SDI cable Instruction manual
121.1 Checking the package contentsUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.1Wireless ReceiverWireless Receiver (UWIT-Y0001-RX)AC adaptor AC cord DVI cable (MAJ-1945) Access sheet
1.1 Checking the package contents13UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.1Optional equipmentThe following products are optional Olympus products that may be purchased separately.Attachment for UWIT (MAJ-Y0149)DVI cable (MAJ-1945)Attachment for UWIT (MAJ-Y0149)Screw (for installing UWIT-Y0001-TX or UWIT-Y0001-RX) (2 pcs.)Screw (for installing OEV261H) (4 pcs.)Screw (for AC adaptor) (2 pcs.) Attachment for AC adaptor Access sheetDVI cable (MAJ-1945) Access sheet
141.1 Checking the package contentsUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.1
2.1 Symbols and descriptions15UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.2Chapter 2 Nomenclature and FunctionsThe instrument nomenclature, functions, and specifications are described in this chapter.Front panelRear panel2.1 Symbols and descriptionsSymbol DescriptionSelectSymbol DescriptionSerial numberPotential equalization terminal
162.2 Front panel of Wireless TransmitterUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.22.2 Front panel of Wireless TransmitterNo. Nomenclature Description1 Power indicator Lights up when the Wireless Transmitter is ON.2 SELECT button When pressed and held for 1 second, the SELECT button switches between the CH1 and CH2 Channels.3 Channel Status displayThe selected Channel (CH1 or CH2) will have a steady light or blink. It blinks while searching to connect to the Wireless Receiver. It will have a steady light when connection has been established.4 Video selection status displaySelected video input selection (SDI or DVI) will have a steady light or blink. It will have a steady light when the Wireless Transmitter detects supported video format, and it will blink when the Wireless Transmitter cannot detect any video signal or unsupported video format is detected.2341
2.3 Rear panel of Wireless Transmitter17UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.22.3 Rear panel of Wireless TransmitterNo. Nomenclature Description1 HD-SDI IN terminal Inputs HD-SDI video signal.2 DC IN terminal This is the 12V DC input terminal. Connect the supplied AC adaptor to this terminal.3 DVI IN terminal Inputs digital video signal.231
182.4 Front panel of Wireless ReceiverUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.22.4 Front panel of Wireless ReceiverNo. Nomenclature Description1 Power indicator Lights up when the Wireless Receiver is ON.2 SELECT button When pressed and held for 1 second, the SELECT button switches between the CH1 and CH2 Channels.3 Channel Status displayThe selected Channel (CH1 or CH2) will have a steady light or blink. It blinks while searching to connect to the Wireless Transmitter. It will have a steady light when connection has been established.2.5 Rear panel of Wireless ReceiverNo. Nomenclature Description1 DC IN terminal This is the 12V DC input terminal. Connect the supplied AC adaptor to this terminal.2 DVI OUT terminal Outputs digital video signal.23112
2.6 AC adapter19UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.22.6 AC adapterNo. Nomenclature Description1 AC IN terminal This is the AC input terminal.1
202.6 AC adapterUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.2
3.1 Precautions for installation and connection21UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3Chapter 3 Installation and ConnectionPrepare this Wireless Image Transmitter Unit and compatible equipment (shown in the “System chart” on page 43) before each use. Referring to the instruction manuals of each system component, install and connect the equipment according to the procedure described in this chapter.WARNINGReview this chapter thoroughly, and prepare the instruments properly before use. If the equipment is not properly prepared before each use, equipment damage, patient and operator injury and/or fire can occur.CAUTION• Use appropriate cables only. Otherwise, equipment damage or malfunction can result.• Properly and securely connect all cables. If the cable connector has a locking mechanism, such as connection screws, lock the cable connector. Otherwise, equipment damage or malfunction, such as no images on the monitor can result.• The cables should not be sharply bent, pulled, twisted or crushed. Cable damage can result.• Use this instrument only under the conditions described in “Environment” on page 46 and “Specifications” on page 48. Otherwise, improper performance, compromised safety and/or equipment damage may result.3.1 Precautions for installation and connection
223.2 Installation of the equipmentUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3Use Attachment for UWIT (MAJ-Y0149) for installing the Wireless Transmitter or Receiver. Check the unused mounting screw holes on the rear panel of OEV261H installed to LCD arm, and fix the Wireless Transmitter or Receiver using supplied screws.3.2 Installation of the equipment1Check the rear panel of OEV261H installed to LCD arm, and align the unused mounting screw holes of OEV261H with the mounting screw holes on the Attachment for UWIT (MAJ-Y0149).Figure 3.12Fix the Attachment for UWIT onto the top back of the high definition LCD monitor OEV261H using the four screws provided with the Attachment for UWIT.3Align the mounting screw holes on the rear of the Wireless Transmitter or Receiver with the mounting screw holes on the Attachment for UWIT.Figure 3.24Fix the Wireless Transmitter or Receiver onto the Attachment for UWIT using two screws provide with the Attachment for UWIT.UWIT-Y0001-TX UWIT-Y0001-RX
3.2 Installation of the equipment23UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3CAUTION• Ensure that the Wireless Transmitter or Receiver is fixed firmly to the high definition LCD monitor OEV261H. Otherwise, the Wireless Transmitter or Receiver may fall and cause injury to the operator or damage the Wireless Transmitter or Receiver.• Use a monitor mount with sufficient load resistance to support the combined weight of the monitor and the Wireless Transmitter or Receiver. If the monitor with the Wireless Transmitter or Receiver falls, patient or operator injury and/or equipment damage may result.• Do not use screws other than those provided with the Attachment for UWIT. Otherwise, the Wireless Transmitter or Receiver cannot be fixed firmly to the Attachment for UWIT and the Wireless Transmitter or Receiver may drop, causing injury to the operator or damage the Wireless Transmitter or Receiver.• Do not install the monitor on mobile workstations other than those listed in this instruction manual. Otherwise, the mobile workstation may tip, injury to the operator or damage of the monitor/equipment on the mobile workstation may result.• When installing the Wireless Transmitter and Receiver to the high definition LCD monitor OEV261H which is on the ceiling arm, ensure that there is no mechanical interference with other moving part of the ceiling arm/pendant.• Check if the unit is intended to install by referring to front or rear panel of the Wireless Transmitter or Receiver before the installation.
243.3 Installation of the AC adaptorUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3WARNINGKeep fluids away from the AC adaptor. Failure to do so may place the patient and medical personnel in danger of an electric shock.Installation on the Attachment for UWIT (MAJ-Y0149)3.3 Installation of the AC adaptorFix the AC adaptor to the Attachment for UWIT using the attachment for AC adapter provided with the Attachment for UWIT.Figure 3.3
3.4 Connecting AC adaptor to Wireless Transmitter or Receiver25UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.33.4 Connecting AC adaptor to Wireless Transmitter or Receiver1Connect the power cord to the AC IN terminal on the AC adaptor.Figure 3.42Insert the DC cord into the DC IN terminal on the Wireless Transmitter or Receiver. Fix DC cord by winding finger screw.Figure 3.5
263.5 Connecting AC adaptor to an AC mains power supplyUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3When using the power cord of mobile workstation (WM-NP1, WM-WP1, WM-DP1)When using the supplied AC cord3.5 Connecting AC adaptor to an AC mains power supply1Connect the power cord provided with the mobile workstation to AC IN terminal of AC adaptor and to the power socket of the mobile workstation.Figure 3.62Connect the power cord of the mobile workstation to wall mains outlet.Connect supplied AC cord to wall mains outlet.AC power inletMobile workstationto the wall mains outletPower socketPower cord provided with the mobile workstationPower cord provided with the mobile workstationPower cord of the mobile workstationAC Adaptor
3.6 Connecting video cables to Wireless Transmitter27UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3Selection of video input terminalUsing SDI IN terminal or DVI IN terminal can be selected for the video input terminal of the Wireless Transmitter. Appropriate video input terminal must be selected according to the video cables to connect with devices as referring to “System chart” on page 43. In the video selection status display to show SDI or DVI, the one lights on or blinks indicates the selected video input terminal. When selecting the different video input terminal, follow the operation below.3.6 Connecting video cables to Wireless Transmitter1Confirm that the power indicator light of Wireless Transmitter is on.If the video input terminal to be used is already selected, skip following operation. Confirm if the SDI or DVI has a steady light or blinks in the video selection status display on the front panel of the Wireless Transmitter. If SDI has a steady light or blinks, it means HD-SDI IN terminal is selected. If DVI has a steady light or blinks, it means DVI IN terminal is selected.2Press and hold SELECT button for about 6 seconds.While press and hold SELECT button, Channel (CH1 or CH2) will switch in about 1 second, however, continue to hold the SELECT button.3Release the finger after confirm that the selection of SDI or DVI is completed in the video selection status display.The one selected blinks or lights on and the other unselected lights off.
283.6 Connecting video cables to Wireless TransmitterUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3Connection diagram (When using HD-SDI)Figure 3.7CAUTION• Ensure that the Wireless Transmitter is fixed firmly to the HD-SDI OUT terminal of the high definition LCD monitor OEV261H.• HD-SDI OUT terminal of the high definition LCD monitor OEV261H through outputs the HD-SDI video signal of HD-SDI IN terminal from such as video system center. Select HD-SDI output in the video output selection of the video system center. The Wireless Transmitter doesn’t support SD-SDI. Do not select SD-SDI in the video output selection.SDI CableOEV261HUWIT-Y0001-TXOTV-S190
3.6 Connecting video cables to Wireless Transmitter29UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3Connection diagram (When using DVI)Figure 3.8CAUTION• Ensure that the Wireless Transmitter fixed firmly to the DVI-D OUT terminal of the video system center or Image management HUB IMH-20.• Select 1080p in the video output selection of the video system center. Do not select the resolutions such as WUXGA in the video output selection that the Wireless Transmitter doesn’t support.• Connect the video system center and OEV261H directly by video cable such as SDI cable (MAJ-1912, MAJ-1464, MAJ-1951).UWIT-Y0001-TXMAJ-1945OEV261HOTV-S190MAJ-1912, MAJ-1464, MAJ-1951
303.7 Connecting video cables to Wireless ReceiverUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.3Connection diagramFigure 3.9CAUTIONEnsure that the Wireless Receiver is fixed firmly to the DVI-D IN terminal of the high definition LCD monitor OEV261H.3.7 Connecting video cables to Wireless ReceiverUWIT-Y0001-RXMAJ-1945OEV261H
4.1 Inspection of the power supply31UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.4Chapter 4 InspectionPrepare the Wireless Image Transmitter Unit and other ancillary equipment before each particular case. Refer to the respective instruction manuals for each piece of equipment.WARNING• Review Chapter 3, “Installation and Connection” thoroughly, and prepare the instruments properly before inspection. If the equipment is not properly prepared before each use, equipment damage, patient and operator injury and/or fire can occur.• Before each case, inspect the Wireless Image Transmitter Unit as instructed below. Inspect other equipment to be used with this Wireless Image Transmitter Unit as instructed in their respective instruction manuals. Should the slightest irregularity be observed, do not use the Wireless image transmitter unit and see Chapter 7, “Troubleshooting”. If the irregularity is still observed after consulting Chapter 7, contact Olympus. Damage or irregularity may compromise patient or user safety and may result in more severe equipment damage.Power indicator lights on when the Wireless Transmitter or Receiver is powered. If power indicator doesn’t light on, check the equipment as follows;4.1 Inspection of the power supplyConfirm that the AC cord, AC adaptor, and the Wireless Transmitter or Receiver are connected as described in Section 3.4, “Connecting AC adaptor to Wireless Transmitter or Receiver” and in Section 3.5, “Connecting AC adaptor to an AC mains power supply”.
324.2 Inspection of the displayed imageUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.44.2 Inspection of the displayed imagePlace the Wireless Transmitter and Receiver face to face without any obstruction in between.Typical communication distance of the Wireless Transmitter and Receiver is about 10 m. Ensure that the distance between the Wireless Transmitter and Receiver is within 10 m.Figure 4.1CAUTION• Do not stand or place obstacles in front of the Wireless Transmitter or Receiver, which may interrupt the RF path.• Noises or interruptions may appear on the image due to the RF interference when the unit using same 60 GHz frequency bands is activated near the Wireless Transmitter or Receiver. Confirm that the image is displayed normally before use.• If the instruments located near the Wireless Transmitter or Receiver use same 60 GHz frequency bands or tend to accept influence of radio frequency, check the instruments works normally by referring to such as the panel display of the instruments after wireless transmission starts between the Wireless Transmitter and Receiver.• Do not place as described below. Noises may appear on the image because the Wireless Transmitter or Receiver cannot perform normally.Do not place the Wireless Transmitter or Receiver low because the RF path may interrupted by the operator/patient or device.Do not place the Wireless Transmitter or Receiver in different direction such as to the ceiling or the floor because the RF path may become insufficient to stabilize the Wireless Transmitter.Do not set either one of the Wireless Transmitter or Receiver upright.
4.2 Inspection of the displayed image33UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.41Turn on the Wireless Transmitter, Receiver and peripheral devices and confirm the image is displayed on the monitor which is connected to the Wireless Receiver.2Confirm that the endoscopic image is normal by observing any object such as the palm of your hand.
344.2 Inspection of the displayed imageUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.4
5.1 Turn the Wireless Transmitter and Receiver ON35UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.5Chapter 5 OperationWhen the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is usedCAUTIONAfter using the Wireless Transmitter or Receiver, turn the mobile workstation off.When the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is not usedCAUTIONAfter using the Wireless Transmitter or Receiver, disconnect the AC cord from the wall mains outlet or from the AC adaptor.5.1 Turn the Wireless Transmitter and Receiver ONTurn the mobile workstation ON.Connect the AC cord of the Wireless Transmitter or Receiver to the wall mains outlet.
365.2 Connection of the Wireless Transmitter and ReceiverUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.5CAUTION• If multiple pairs of Wireless Transmitters and Receivers are to be used in adjacent areas, the connection between the paired Wireless Transmitter and Receiver may not complete, or the Wireless Transmitter may establish connection to the incorrect Receiver (cross-talk). To avoid connection issues or cross-talk when multiple Wireless Image Transmitter Units are installed, select different Channels and/or turn off other Unit(s).• When the Wireless Transmitter is turned off after the Wireless Transmitter and Receiver are connected, the Wireless Receiver automatically searches a Wireless Transmitter which is ready to connect. If the Wireless Receiver detects another Wireless Transmitter which is ready to connect, they may connect automatically. Operate as below to reconnect with the original Wireless Transmitter.NOTE• A Wireless Transmitter can connect to only one Wireless Receiver at a time.• When the Wireless Transmitter or Receiver is turned OFF after connection has been established, the Wireless Transmitter search same Receiver automatically when turn ON. If the Wireless Receiver is ON and ready to connect, the Wireless Transmitter connects to it automatically.5.2 Connection of the Wireless Transmitter and Receiver1Prepare the Wireless Transmitter and Receiver to be connected, and turn them ON. 2Press and hold the SELECT button of Wireless Transmitter for about 1 second.The Wireless Transmitter will seek connection to the Wireless Receiver when the SELECT button is pressed and held for about 1 second. Ensure that the Wireless Transmitter and Receiver have the same channel selected. To change the Channel, press and hold the SELECT button again until the intended channel blinks.3The CH light will blink during the connection process. The CH light will be steady once the Wireless Transmitter and Receiver are connected.If CH light continues to blink and connection cannot be established, please refer to Chapter 7, “Troubleshooting”.
6.1 Care37UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.6Chapter 6 Care, Storage, and DisposalWARNING• After wiping with a piece of moistened gauze, dry the Wireless Image Transmitter Unit thoroughly before using it again. If it is used while still wet, there is the risk of an electric shock.• When cleaning the Wireless Image Transmitter Unit, always wear appropriate personal protection equipment such as eye wear, face mask, moisture-resistant clothing, and chemical-resistant gloves that fit properly and are long enough to that your skin is not exposed. Blood, mucus, and other potentially infectious material adhering to the Wireless Image Transmitter Unit could pose an infection control risk.CAUTION• Do not clean the video connector socket and the AC mains power inlet. Cleaning them can deform or corrode the contacts, which could damage the Wireless Image Transmitter Unit.• Do not wipe the external surface with hard or abrasive wiping material. The surface will be scratched.After using the Wireless Image Transmitter Unit, immediately perform the following cleaning procedures. If cleaning is delayed, residual organic debris will begin to solidify, and it may be difficult to effectively clean the Wireless Image Transmitter Unit. Always remove debris routinely.6.1 Care1Disconnect the power cords of Wireless Image Transmitter Unit from the wall mains outlet or the power socket of the mobile workstation.2When the Wireless Image Transmitter Unit is soiled with blood or other potentially infectious materials, wipe off all debris using a piece of gauze moistened with neutral detergent.3Remove dust, dirt, and other stains on the surface by wiping with a piece of gauze moistened with 70% ethyl or isopropyl alcohol.4Make sure to dry the Wireless Image Transmitter Unit after wiping with 70% ethyl or isopropyl alcohol.
386.2 StorageUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.6CAUTIONDo not store the Wireless Image Transmitter Unit in a location exposed to direct sunlight, X-rays, radio activity or strong electromagnetic radiation (e.g., near microwave medical treatment equipment, short-wave medical treatment equipment, MRI, radio equipment, or cellular phones). Damage to the Wireless Image Transmitter Unit may result.When disposing of this instrument or any of its components (such as fuses), follow all applicable national and local laws and guidelines.6.2 Storage1Disconnect the power cords of the Wireless Image Transmitter Unit from the wall mains outlet or the power socket of the mobile workstation.2Disconnect the cables connected to the Wireless Image Transmitter Unit.3Store the equipment in the level position in a clean, dry, and stable location.6.3 Disposal
7.1 Troubleshooting39UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.7Chapter 7 TroubleshootingIf any irregularity is observed during inspection as described in Chapter 4, “Inspection” or using as described in Chapter 5, “Operation”, do not use the Wireless Image Transmitter Unit and attempt to solve the problem as described in Section 7.2, “Troubleshooting guide”. If the problem still cannot be resolved, contact Olympus.DANGERNever use the Wireless Image Transmitter Unit if an irregularity is observed. Damage or irregularity of the Wireless Image Transmitter Unit may compromise patient or user safety and may result in more severe equipment damage.7.1 Troubleshooting
407.2 Troubleshooting guideUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.7The following table shows the possible causes of and countermeasures against troubles that may occur due to equipment setting errors or deterioration of consumable. Troubles or failures other than those listed in the following table need repair. If repair is performed by persons who are not qualified by Olympus, patient or user injury and/or equipment damage may result. Be sure to contact Olympus for repair.WARNINGIf an irregularity is observed, turn the Wireless Image Transmitter Unit OFF once and turn it ON again. If the irregularity cannot be solved, turn the Wireless Image Transmitter Unit OFF and disconnect the power cord to stop the flow of electricity completely.7.2 Troubleshooting guideIrregularity description Possible cause SolutionThe power fails to come on. The AC adaptor is not connected correctly.Connect AC adaptor to Wireless Transmitter or Receiver as described in Section 3.4, “Connecting AC adaptor to Wireless Transmitter or Receiver”.The AC cord is not connected correctly. Connect AC cord to AC adaptor as described in Section 3.5, “Connecting AC adaptor to an AC mains power supply”.The mobile workstation is OFF. Turn the mobile workstation ON.The endoscopic image does not appear on the monitor while SDI is blinking in the video selection status display.The video system center is OFF. Turn the video system center ON.The SDI cable is not connected correctly.Connect the SDI cable correctly.A wire in the cable is disconnected. Replace the cable with new one.Unsupported video signal such as SD-SDI is input.Input HD-SDI video signal.The endoscopic image does not appear on the monitor while DVI is blinking in the video selection status display.The video system center is OFF. Turn the video system center ON.The DVI cable is not connected correctly.Connect the DVI cable correctly.A wire in the cable is disconnected. Replace the cable with new one.Unsupported video signal such as WUXGA is selected as an input from the video system center.Input digital video signal of 1080p (60Hz/50Hz) or SXGA: 1280 × 1024 (60Hz).HDCP is input The Wireless Transmitter doesn’t support HDCP. Connect with the device which doesn’t output HDCP signal.
7.2 Troubleshooting guide41UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.7The endoscopic image does not appear on the monitor while CH1 or CH2 blinks.The CH of the transmitter and the receiver is different.Press the SELECT button of the transmitter and set to same CH.Other ID of the receiver remains in transmitter.Press the SELECT button to clear the remained receiver ID. Press the SELECT button again if the CH of the transmitter and the receiver is different.The Wireless Transmitter or Receiver is used in same frequency range in the vicinity. (RF interference).Confirm the CH of the Wireless Transmitter or Receiver in the vicinity and set different CH.The endoscopic image does not appear on the monitor while CH1 or CH2 lights on.The monitor is OFF. Turn the monitor ON.Different video input terminal is selected in monitor.Select appropriate video input terminal in monitor.The endoscopic image does not appear on the monitor while nothing lights on the Wireless Transmitter or Receiver.The power cord is disconnected. Connect the power cord to AC adaptor referring to Section 3.5, “Connecting AC adaptor to an AC mains power supply”.The mobile workstation is OFF. Turn the mobile workstation ON.Nothing lights on or blinks other than power indicator.This symptom may be caused by a malfunction in the circuit of the Wireless Transmitter or Receiver.Turn the Wireless Transmitter or Receiver off, wait 10 seconds or more and turn on again. If the irregularity cannot be solved, contact Olympus.The Wireless Transmitter or Receiver repeats reboot automatically.This symptom may be caused by a malfunction in the circuit of the Wireless Transmitter or Receiver.Turn the Wireless Transmitter or Receiver off, wait 10 seconds or more and turn on again. If the irregularity cannot be solved, contact Olympus.Irregularity description Possible cause Solution
427.3 Returning the Wireless Image Transmitter Unit for repairUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCh.7CAUTIONOlympus is not liable for any injury or damage which occurs as a result of repairs attempted by non-Olympus personnel.When returning the Wireless Image Transmitter Unit for repair, contact Olympus. With the Wireless Image Transmitter Unit, include a description of the malfunction or damage and the name and telephone number of the individual at your location who is most familiar with the problem. Include a repair purchase order.7.3 Returning the Wireless Image Transmitter Unit for repair
App.Combination equipment43UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALAppendixThe equipment compatible with this endoscope and the EMC information are described in this Appendix.System chartThe recommended combinations of equipment that can be used with this Wireless Image Transmitter Unit are listed below. New products released after the introduction of the Wireless Image Transmitter Unit may also be compatible for use in combination with it. For further details, contact Olympus.WARNINGIf combinations of equipment other than those shown below are used, the full responsibility should be assumed by the medical treatment facility. Such combinations do not only allow the equipment to manifest their full functionality but may also imperil the safety of the patient and medical personnel. In addition, the endurance of the Wireless Image Transmitter Unit and ancillary equipment is not guaranteed. Troubles caused in this case are not covered by free-of-charge repair. Be sure to use the equipment in one of the recommended combinations.Combination equipment
App.44Combination equipmentUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALHigh definition LCD monitor (OEV261H)Mobile Workstation (WM-NP1, WM-WP1, WM-DP1)VISERA ELITE video system center (OTV-S190)EVIS EXCERA III video system center (CV-190)High definition LCD monitor (OEV261H)Attachment for UWIT (MAJ-Y0149)Wireless Transmitter (UWIT-Y0001-TX)LCD Arm (MAJ-181)Wireless Receiver (UWIT-Y0001-RX)Install the high definition LCD monitor OEV261H with Wireless Receiver in the level position in a stable location.* These products enclosed with the dotted line conform to EMC (Ed.3)Attachment for UWIT (MAJ-Y0149) Image management HUB (IMH-20)Image management HUB (IMH-10)Image management HUB (IMH-20)Color video printer (OEP-5)
App.FCC (for Wireless Transmitter and Receiver)45UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television, reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.This equipment complies with FCC/IC radiation exposure limits set forth for a controlled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65 and RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). But it should be installed and operated keeping the radiator at least 20 cm or more away from person’s body (excluding extremities: hands, wrists, feet and ankles).Cet équipement est conforme aux limites d’exposition aux rayonnements énoncées pour un environnement contrôlé et respecte les régles les radioélectriques (RF) de la FCC lignes directrices d’exposition dans le Supplément C à OET65 et d’exposition aux fréquences radioélectriques (RF) CNR-102 de l’IC. Cet équipement émet une énergie RF très faible qui est considérée conforme sans évaluation de l’exposition maximale autorisée. Cependant, cet équipement doit être installé et utilisé en gardant une distance de 20 cm ou plus entre le dispositif rayonnant et le corps (à l’exception des extrémités: mains, poignets, pieds et chevilles).FCC (for Wireless Transmitter and Receiver)FCC/IC (for Wireless Transmitter and Receiver)
App.46SpecificationsUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALEnvironmentSpecificationsOperating environment Ambient temperature 10 – 40qC (50 – 104qF)Relative humidity 30 – 85% (without condensation)Atmospheric pressure  700 – 1060 hPaUsage location Indoor use onlyTransportation and storage environmentAmbient temperature –25 to +70qC (–13 to +158qF)Relative humidity 10 – 90%Atmospheric pressure 700 – 1060 hPa
App.Specifications47UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALMaximum 2 pairs (2 Transmitters, 2 Receivers) can be used simultaneously in a room completely enclosed by walls and doors. Set CH1 for one pair and CH2 for the other.CAUTION• Inspect the unit before use as described in this manual.• Do not use more than 2 pairs in an enclosed room simultaneously. If more than 2 pairs are used simultaneously, interference may cause noise or interruption of images.• The RF signal may go beyond the wall of room due to the material of the wall (e.g., part of the wall is glass). In that case, confirm before use that no interference from neighboring rooms by using different Channels in neighboring rooms as shown below. If interference still occurs, consider installing the Wireless Image Transmitter Unit in alternating rooms (every other room).CH1 CH2 CH1 CH2 CH1 CH2CH1 CH2 CH1CH1 CH2 CH1 CH2
App.48SpecificationsUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALSpecificationsUWIT-Y0001-TX Dimensions 234 (W) × 69 (H) × 43 (D) mmDimensions (maximum) 234 (W) × 69 (H) × 59 (D) mmWeight 0.41 kgVoltage DC 12 V, 1 AVideo signal inputSDI input connector BNC (×1)DVI input connectorDVI (×1)No support for HDCPUWIT-Y0001-RX Dimensions 208 (W) × 54 (H) × 45 (D) mmDimensions (maximum) 208 (W) × 54 (H) × 60 (D) mmWeight 0.31 kgVoltage DC 12 V, 0.8 AVideo signal outputDVI output connector DVI (×1)AC adaptor Dimensions 120 (W) × 38 (H) × 60 (D) mmDimensions (include cable) 3020 (W) × 38 (H) × 60 (D) mmWeight 0.34 kgVoltage AC IN 100 – 240 V, 50/60 Hz, 1 – 0.5 ADC OUT 12 V, 3 AEMC Applied standard IEC 60601-1-2: 2001• This instrument complies with the EMC standard for medical electrical equipment, edition 2 (IEC 60601-1-2: 2001). However, when connecting to an instrument that complies with the EMC standard for medical electrical equipment, edition 1 (IEC 60601-1-2: 1993), the whole system complies with edition 1.• CISPR 11 of emission:Group 1, Class BYear of manufacture The last digit of the year of manufacture is the second digit of the serial number. In this example, the year is 2009.Ex. 7901234 (serial number)FCC ID UWIT-Y0001-TX: S8Q-RU5796UWIT-Y0001-RX: S8Q-RU5808This device complies with part 15 of the FCC Rules (FCC Part 15 Subpart C §15.255). Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
App.Specifications49UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALIC UWIT-Y0001-TX: 4763B-RU5796UWIT-Y0001-RX: 4763B-RU5808This device complies with Industry Canada license-exempt RSS standard(s).Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, méme si le brouillage est susceptible d’en compromettre le fonctionnement.This Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
App.50EMC informationUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALThis model is intended for use in the electromagnetic environments specified below. The user and the medical staff should ensure that it is used only in these environments.Magnetic emission compliance information and recommended electromagnetic environmentsEMC informationEmission standard Compliance GuidanceRF emissionsCISPR 11Group 1 This instrument uses RF (Radio Frequency) energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.Radiated emissionsCISPR 11Class B This instrument’s RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.Main terminal conducted emissionsCISPR 11Harmonic emissionsIEC 61000-3-2Class A This instrument’s harmonic emissions are low and are not likely to cause any problem in the typical commercial power supply connected to this instrument.Voltage fluctuations/flicker emissionsIEC 61000-3-3Complies This instrument stabilizes its own radio variability and has no effect such as flicker in lighting apparatus.
App.EMC information51UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALElectromagnetic immunity compliance information and recommended electromagnetic environmentsNOTEUT is the AC mains power supply prior to application of the test level.Immunity test IEC 60601-1-2 test level Compliance level GuidanceElectrostatic discharge (ESD)IEC 61000-4-2Contact:r2, r4, r6kVAir:r2, r4, r8kVSame as left Floors should be made of wood, concrete, or ceramic tile that hardly produces static. If floors are covered with synthetic material that tends to produce static, the relative humidity should be at least 30%.Electrical fast transient/burstIEC 61000-4-4r2kV for power supply linesr1kV for input/output linesSame as left Mains power quality should be that of a typical commercial (original condition feeding the facilities) or hospital environment.SurgeIEC 61000-4-5Differential mode:r0.5, r1kVCommon mode:r0.5, r1, r2kVSame as left Mains power quality should be that of a typical commercial or hospital environment.Voltage dips, short interruptions, and voltage variations on power supply input linesIEC 61000-4-11< 5% UT(> 95% dip in UT)for 0.5 cycleSame as left Mains power quality should be that of a typical commercial or hospital environment. If the user of this instrument requires continued operation during power mains interruptions, it is recommended that this instrument be powered from an uninterruptible power supply or a battery.40% UT(60% dip in UT)for 5 cycle70% UT(30% dip in UT)for 25 cycle< 5% UT(> 95% dip in UT)for 5 secondsPower frequency (50/60 Hz) magnetic fieldIEC 61000-4-83 A/m Same as left It is recommended to use this instrument by maintaining enough distance from any equipment that operates with high current.
App.52EMC informationUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALCautions and recommended electromagnetic environment regarding portable and mobile RF communications equipment, such as cellular phonesNOTE• Where “P” is the maximum output power rating of the transmitter*1 in watts (W) according to the transmitter*1 manufacturer, and “d” is the recommended separation distance in meters (m).• This instrument complies with the requirements of IEC 60601-1-2: 2001 and IEC 60601-1-2: 2007. However, under an electromagnetic environment that exceeds its noise level, electromagnetic interference may occur on this instrument.• Electromagnetic interference may occur on this instrument near a high-frequency electrosurgical equipment and/or other equipment marked with the following symbol:Immunity test IEC 60601-1-2 test levelCompliance level GuidanceConducted RFIEC 61000-4-63Vrms(150 kHz – 80 MHz)3V (V1) Formula for recommended separation distance (V1=3 according to the compliance level)Radiated RFIEC 61000-4-33V/m(80 MHz – 2.5 GHz)3V/m (E1) Formula for recommended separation distance (E1=3 according to the compliance level)80 MHz – 800 MHz800 MHz – 2.5 GHz*1 The word “Transmitter” is generic term used for conventional portable and mobile RF communication equipment such as cellular phones.d3.5V1------- P=d3.5E1------- P=d7E1------P=
App.EMC information53UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALRecommended separation distance between portable and mobile RF communications equipment and this instrumentNOTEThe guidance may not apply in some situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.Portable and mobile RF communications equipment such as cellular phones should be used no closer to any part of this instrument, including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter*1.Rated maximum output power of transmitter*1P (W)Separation distance according to frequency of transmitter*1 (m)(calculated as V1=3 and E1=3)150 kHz – 80 MHz 80 MHz – 800 MHz 800 MHz – 2.5 GHz0.01 0.12 0.12 0.230.1 0.38 0.38 0.7311.2 1.2 2.310 3.8 3.8 7.3100 12 12 231 The word “Transmitter” is generic term used for conventional portable and mobile RF communication equipment such as cellular phones.d1.2 P=d1.2 P=d2.3 P=
App.54FCC WARNINGUWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUALChange or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.FCC WARNINGDeclaration of ConformityTrade Name: OLYMPUS MEDICAL SYSTEMSModel: UWIT-Y0001-TX, UWIT-Y0001-RXResponsible Party: OLYMPUS AMERICA INC.Address: 3500 Corporate Parkway, P.O. Box 610 Center Valley,PA 18034-0610, U.S.A.Telephone Number: (484)896-5000
©2011 OLYMPUS MEDICAL SYSTEMS CORP. All rights reserved.No part of this publication may be reproduced or distributed without the express written permission of OLYMPUS MEDICAL SYSTEMS CORP.OLYMPUS is a registered trademark of OLYMPUS CORPORATION.Trademarks, product names, logos, or trade names used in this document are generally registered trademarks or trademarks of each company.
 Printed in Japan 20110629 *0000XGT8045  01Manufactured by2951 Ishikawa-cho, Hachioji-shi, Tokyo 192-8507, JapanFax: (042)646-2429  Telephone: (042)642-2111(Premises/Goods delivery) Wendenstrasse 14-18, 20097 Hamburg, Germany(Letters) Postfach 10 49 08, 20034 Hamburg, Germany3500 Corporate Parkway, P.O. Box 610, Center Valley, PA18034-0610, U.S.A.Fax: (484)896-7128  Telephone: (484)896-5000KeyMed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, United KingdomFax: (01702)465677  Telephone: (01702)616333491B, River Valley Road #12-01/04, Valley Point Office Tower, Singapore 248373Fax: 6834-2438  Telephone: 6834-0010A8F, Ping An International Financial Center, No. 1-3, Xinyuan South Road,Chaoyang District, Beijing, 100027 P.R.C.Fax: (86)10-5976-1299  Telephone: (86)10-5819-9000117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, RussiaFax: (095)958-2277  Telephone: (095)958-224531 Gilby Road, Mount Waverley, VIC., 3149, AustraliaFax: (03)9543-1350  Telephone: (03)9265-54005301 Blue Lagoon Drive, Suite 290 Miami, FL 33126-2097, U.S.A.Fax: (305)261-4421  Telephone: (305)266-2332Distributed byOlympus-Tower, 114-9 Samseong-Dong, Gangnam-Gu, Seoul 135-090 KoreaFax: (02)6255-3494  Telephone: (02)6255-3210Fax: (040)23773-4656  Telephone: (040)23773-0