BF-160 Endoscopic Equipment Combinations

Single-use Suction Valve (MAJ-209)
or Suction Valve (MAJ-207)

Single-use Biopsy Valve (MAJ-210)
or Biopsy Valve (MD-495)

EVIS EXERA Bronchovideoscope

OLYMPUS

BF TYPE 160

Suction Pump (KV‐4 / SSU‐2)

Videoscope Cable EXERA (MAJ-843)

*Videoscope Cable 100 (MD-680 or MD-146)

Revolutionary Observation
Capability
EVIS EXERA Video System Center (CV-160)

*EVIS Video System Center (CV‐100 / 140)

EVIS EXERA Light Source (CLV-160)

*EVIS Universal Light Source (CLV‐U20 / 40)

*BF-P160 is not compatible

http://www.olympus.com

San-Ei Building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku, Tokyo, Japan
Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-16, 20097 Hamburg, Germany

2 Corporate Center Drive, Melville, N.Y. 11747-3157, U.S.A.
Keymed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, England
491B River Valley Road #12-01/04,Valley Point Office Tower,Singapore 248373
Rm. 818, South Tower, Beijing Kerry Centre, No.1 Guanghua Road, Chaoyang District, Beijing, 100020, China
117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia
1/104 Ferntree Gully Road, Oakleigh, VIC 3166, Australia

Printed in Japan R264SB-0400

BF-160* Doc.00.3/6 00.5.24 1:29 PM ページ 3

A 5.3mm Diameter Distal End, Newly
Developed High-Resolution CCD, And
Compatibility With The EVIS 100/140 Systems
With its slim 5.3mm diameter distal end, 2.0mm diameter channel, and newly developed
high-resolution CCD, the Olympus BF TYPE 160 makes it easy to obtain the precision
manipulation and detailed imaging you need for examination of the tracheobronchial tree.
Equally well-suited for routine endoscopic applications, this versatile scope is fully
compatible with the CV-160 as well as the CV-100/140, offering you a cost-effective
solution to all your endoscopic requirements.

EVIS EXERA Bronchovideoscope

OLYMPUS

BF TYPE 160

High-Quality, High-Resolution Images
For Accurate Observation
The BF-160 incorporates a newly developed compact color-chip CCD in the scope
tip capable of delivering the same level of high-resolution image quality as a
gastrointestinal videoscope. Details are sharp and clear throughout the image area,
assuring precise, and accurate observation.

Larger Image Size For Easier Viewing
Monitoring the image while you work is much easier with the BF-160 thanks to its
larger image display. Since this increased size does not come at the expense of
image quality, you’ll easily spot tiny details that you might otherwise have missed.

EVIS EXERA
Bronchovideoscope

BF-160

Backward Compatibility And Dual-Purpose Design For
Optimal Cost-Efficiency
Fully compatible with our earlier CV-100 and CV-140 video system centers, the
BF-160 can be easily integrated into the EVIS 100/140 systems used in GI endoscopy

Specifications
Optical System

suite. On the other hand, if you’re ready to upgrade and want to maximize the costefficiency of your endoscopy suite, you’ll appreciate the versatility of the BF-160’s
dedicated video system — the CV-160. Designed to accommodate both
bronchovideoscopes and gastrointestinal videoscopes, the CV-160 allows you to
interchange the BF-160 with an EVIS EXERA Gastrointestinal Videoscope, enabling
your EVIS EXERA System to be used for both bronchoscopic and gastrointestinal
endoscopic procedures.

Insertion Tube

Field of view
Direction of view
Depth of field
Distal end outer diameter
Insertion tube outer diameter
Working length

Channel inner diameter
Instrument Channel
Minimum visible distance
Angulation range
Bending Section
High Frequency Compatibility
Laser Compatibility
Total Length

120°
0° (Forward viewing)
3 ~ 100 mm
5.3 mm
5.2 mm
600 mm

。
180 UP
。
130 DOWN

Light Guide
Instrument
and Suction
Channel

Objective Lens
Light Guide

2.0 mm
3 mm from distal end
UP 180°, DOWN 130°
YES
YAG, 810 nm diode
870 mm

BF TYPE 160
VIDEOSCOPE

Efficient, Ergonomic Design Is Easy To Use And Maintain
CV-100

CV-140

CV-160

5.3mm Diameter Distal End Achieves Excellent Insertion
Capability
Because the distal end’s outer diameter measures only 5.3mm, insertion is smooth
and easy — even when penetrating tight recesses of the tracheobronchial tree. At
the same time, this narrower outer diameter also allows you to use the BF-160 for
routine examination of the bronchi.

Ergonomically Designed Control Section And Switch Layout

Compatibility With Electrocautery For Added Versatility

Designed to minimize operator fatigue and
maximize efficiency, the control section is
contoured to fit comfortably in the operator’s left
hand. Switch functions can be user-defined and all
switches and knobs are arranged on the control
section in a simple, easy-to-remember
configuration that facilitates single-handed
operation.

Fully insulated to minimize any potential risk, this
scope is compatible with electrocautery — an
advanced treatment system that produces less
smoke than laser treatment and is widely used for
specialized surgery such as removal of elevated
tumors in the bronchi.

Reprocessing Capability For Reliability You Can Count On

Standardized Accessories Can Be Used With All Scopes

To make the scope easier to wash and brush and
to optimize the effect of disinfectant immersion, the
exterior is designed to minimize surface protrusions
and indentations while the interior features a
simplified, jointless channel configuration. For
added convenience, all reprocessing accessories
are either autoclavable or disposable.

The accessories are designed to the same
specifications as those for Olympus’s previous and
current bronchovideoscopes and
bronchofiberscopes. This makes it easy to use the
same accessory with different scopes, reducing
equipment costs and simplifying accessory
management.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2000:05:24 13:33:46
Producer                        : Acrobat Distiller 3.0J (Power Macintosh 版)
Author                          : 
Creator                         : QuarkXPressþ: LaserWriter 8 J1-8.4.2
Title                           : Sales Brochure: BF-160 EVIS EXERA Bronchovideoscope
Modify Date                     : 2000:09:11 15:45:54-04:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu