INSTRUCTION MANUAL

7 series
Automatic Wrist Blood
Pressure Monitor

ENGLISH

ESPAÑOL

Model BP652

TABLE OF CONTENTS
Before using the Monitor
Introduction ......................................................................................................... 3
Safety Information ................................................................................................ 4
Operating the Device .......................................................................... 4
Care and Maintenance ......................................................................... 5
Operating Instructions
Before Taking a Measurement .............................................................................. 6
Know Your Unit ................................................................................................... 7
Unit Display ......................................................................................................... 8
Display Symbols ................................................................................................... 9
Irregular Heartbeat Symbol.................................................................. 9
Movement Error Symbol .................................................................... 9
Battery Installation ............................................................................................. 11
Setting the Date and Time .................................................................................. 13
Setting the Advanced Positioning Sensor (APS) ................................................. 15
Setting the Positioning Indicator........................................................ 15
Setting for Right or Left Wrist Measurement ................................... 16
Setting the Buzzer .............................................................................. 16
Resetting to the Default Setting ......................................................... 17
Applying the Wrist Cuff ..................................................................................... 18
Applying the Cuff on the Left Wrist .................................................. 18
Applying the Cuff on the Right Wrist ................................................ 19
Taking a Measurement ....................................................................................... 20
Using the Memory Function ............................................................................... 22
Averaging Function ............................................................................ 22
To Display the Measurement Values ................................................. 22
To Delete All Values Stored in the Memory ..................................... 23
Care and Maintenance ............................................................................................... 24
Error Indicators ................................................................................................... 25
Troubleshooting Tips ........................................................................................... 26
FCC Statement .................................................................................................... 27
Limited Warranty ................................................................................................ 28

6SHFL¿FDWLRQV..................................................................................................... 29

2

INTRODUCTION
Thank you for purchasing the OMRON® BP652 IntelliSense® Automatic Wrist Blood
Pressure Monitor.

Fill in for future reference.
DATE PURCHASED:__________________
SERIAL NUIMBER:___________________
s 3TAPLE YOUR PURCHASE RECEIPT HERE
s 2EGISTER YOUR PRODUCT ON
LINE AT
WWWREGISTER
OMRONCOM
The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for
people who frequently monitor their own blood pressure.
Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through
your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
Clinical research has proven a direct relationship between blood pressure in the wrist
DQGEORRGSUHVVXUHLQWKHDUP&KDQJHVLQZULVWEORRGSUHVVXUHUHÀHFWFKDQJHVLQDUP
blood pressure because the arteries in the wrist and the arm are close to each other.
Frequently measuring the blood pressure in your wrist will provide your physician with
an accurate indication of changes in your blood pressure.
The BP652 comes with the following components:
‡0RQLWRU‡6WRUDJH&DVH‡³$$$´$ONDOLQH%DWWHULHV
‡,QVWUXFWLRQ0DQXDOSULQWHGLQ(QJOLVKDQG6SDQLVK‡4XLFN6WDUW*XLGH
The BP652 IntelliSense® Automatic Wrist Blood Pressure Monitor is intended for home use.

SAVE THESE INSTRUCTIONS
3

SAFETY INFORMATION
To assure the correct use of the product, basic safety measures should always be
followed including the warnings and cautions listed in this instruction manual.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING

Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury to the user or patient or
damage to the equipment or other property.

OPERATING THE DEVICE
&RQWDFW\RXUSK\VLFLDQIRUVSHFL¿FLQIRUPDWLRQDERXW\RXUEORRGSUHVVXUH
Self-diagnosis and treatment using measured results may be dangerous. Follow the
instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on measurement results from this blood pressure
monitor. Take medication as prescribed by your physician. Only a physician is
TXDOL¿HGWRGLDJQRVHDQGWUHDW+LJK%ORRG3UHVVXUH
The monitor is not intended to be a diagnostic device.
,IEDWWHU\ÀXLGVKRXOGJHWLQ\RXUH\HVLPPHGLDWHO\ULQVHZLWKSOHQW\RIFOHDQ
water. Contact a physician immediately.
If you have a condition that may compromise circulation, you may get an inaccurate
reading with this device. Consult your physician before using this device.
Read all of the information in the instruction manual and any other literature in the
box before operating the unit.
This device is intended for use in measuring blood pressure and pulse rate in the
adult population. Do not use this device on infants or persons who cannot express
their intentions.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable
local regulations. Unlawful disposal may cause environmental pollution.

4

SAFETY INFORMATION
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not
approved for use with the device may damage the unit.
8VHRQO\9³$$$´DONDOLQHEDWWHULHVZLWKWKLVGHYLFH'RQRWXVHRWKHUW\SHVRI
batteries. This may damage the unit.
CARE AND MAINTENANCE
'RQRWVXEMHFWWKHPRQLWRUWRVWURQJVKRFNVVXFKDVGURSSLQJWKHXQLWRQWKHÀRRU
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
&KDQJHVRUPRGL¿FDWLRQQRWDSSURYHGE\WKHPDQXIDFWXUHUZLOOYRLGWKHXVHU
warranty. Do not disassemble or attempt to repair the unit or components.

5

BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes
before taking a measurement. Rest for at least 15 minutes before taking the
measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. The cuff can be applied to your left or right wrist.
4. Measurements should be taken in a quiet place.
5. Position the unit at heart level throughout the measurement.
6. Remain still and do not talk during the measurement.
7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return
to the condition prior to taking the blood pressure measurement. You may need to
increase the wait time depending on your individual physiological characteristics.
8. Keep a record of your blood pressure and pulse readings for your physician. A
single measurement does not provide an accurate indication of your true blood
pressure. You need to take and record several readings over a period of time. Try to
measure your blood pressure at the same time each day for consistency.

6

KNOW YOUR UNIT
Main Unit:
Display

Wrist cuff
Memory (MEM)
button
START/STOP button

Date/Time setting
( ) button

User ID selection
switch
SET button

Date/Time setting
( ) button
Battery compartment

Components:

INSTRUCTION MANUAL
7 series
Automatic Wrist Blood
Pressure Monitor
Model BP652
5329415-9A

INTRODUCTION
Thank you for purchasing the OMRON ® BP652 IntelliSense® Automatic Wrist Blood
Pressure Monitor .

Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
s 3TAPLE Your PURCHASe rECEIPT HERE

2 “AAA” Alkaline Batteries

Instruction
Manual

7

Quick Start
Guide

UNIT DISPLAY
Positioning indicator
Diastolic blood pressure
Memory symbol
(Displayed when viewing
values stored in memory)
Average value symbol
(Refer to “Using the
Memory Function” .)
Irregular heartbeat symbol

Systolic blood pressure
Deflation symbol

Movement error symbol
(Displayed if you move
your body during the
measurement)

Blood pressure level
indicator
Buzzer symbol

User ID symbol (A or B)
(If ³GUEST´ is selected, A
or B will not be displayed.)
Wrist symbol

Date/Time display
Heartbeat symbol
(Flashes during
measurement)

Battery low symbol
Pulse display

8

DISPLAY SYMBOLS
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during the
measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the
measurement values.
$QLUUHJXODUKHDUWEHDWUK\WKPLVGH¿QHGDVD
.ORMAL (EARTBEAT
rhythm that varies by less than 25% from the
Pulse
average rhythm or 25% more than the average
Blood
rhythm detected while the monitor is measuring
pressure
the systolic and diastolic blood pressure.
If the irregular heartbeat symbol ( )
)RREGULAR (EARTBEAT
displays with your measurement results,
Short Long
we recommend you consult your
Pulse
physician. Follow the directions of your
Blood
doctor.
pressure
MOVEMENT ERROR SYMBOL ( )
The Movement Error Symbol ( ) is displayed if you move your body during the
measurement. Please remove the wrist cuff, and wait 2-3 minutes. Reapply the wrist
cuff and take another measurement.
Internationally recognized guidelines for upper limit of
normal home blood pressure readings are as follows:

Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure

135 mmHg

Diastolic Blood Pressure

85 mmHg

9

DISPLAY SYMBOLS
This is a general guideline because blood pressure depends on age and morbidity.
A lower home blood pressure goal may be recommended for certain patients,
including diabetic patients, pregnant women, and patients with renal failure.
WARNING
&RQWDFW\RXUSK\VLFLDQIRUVSHFL¿FLQIRUPDWLRQDERXW\RXUEORRGSUHVVXUH
Self-diagnosis and treatment using measured results may be dangerous.
Follow the instructions of your physician or licensed healthcare provider.
WARNING
DO NOT adjust medication based on measurement results from this blood
pressure monitor. Take medication as prescribed by your physician. Only
DSK\VLFLDQLVTXDOL¿HGWRGLDJQRVHDQGWUHDW+LJK%ORRG3UHVVXUH
WARNING
The monitor is not intended to be a diagnostic device.

10

BATTERY INSTALLATION
CAUTION
8VHRQO\9³$$$´DONDOLQHEDWWHULHVZLWKWKLVGHYLFH
1. Press the hook on the bottom of the battery cover
and lift the cover off in the direction of the arrow.

 ,QVWDOO³$$$´VL]HEDWWHULHVVRWKHSRVLWLYHDQG
(negative) polarities match the polarities of the battery
compartment as indicated.
3. Set the date and time.
 5HIHUWR³6HWWLQJWKH'DWHDQG7LPH´
4. Replace the battery cover.
NOTE: Make sure that the battery cover is securely in
position.

11

BATTERY INSTALLATION
BATTERY REPLACEMENT
Low Battery Indicator
When the Low Battery Indicator appears on the display, turn the monitor off and
remove all the batteries. Replace with 2 new batteries at the same time. Long-life
alkaline batteries are recommended.
WARNING
,IEDWWHU\ÀXLGVKRXOGJHWLQ\RXUH\HVLPPHGLDWHO\ULQVHZLWK
plenty of clean water. Contact a physician immediately.
NOTES: ‡7XUQWKHXQLWRIIEHIRUHUHSODFLQJWKHEDWWHULHV,IWKHEDWWHULHVDUHUHPRYHG
while the unit is still on, the date and time will be reset to that of the
previous use. The measurement results are not deleted.
‡:KHQWKHEDWWHULHVDUHUHSODFHG\RXPD\QHHGWRUHVHWWKHGDWHDQGWLPH,I
WKH\HDULVÀDVKLQJRQWKHGLVSOD\UHIHUWR³6HWWLQJWKH'DWHDQG7LPH´
‡7KHEDWWHULHVLQFOXGHGZLWKWKHGHYLFHPD\KDYHDVKRUWHUOLIH
CAUTION
Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental
pollution.

12

SETTING THE DATE AND TIME
6HWWKHPRQLWRUWRWKHFXUUHQWGDWHDQGWLPHEHIRUHWDNLQJDPHDVXUHPHQWIRUWKH¿UVW
time.
1. TO START THE SETTING
Press the Date/Time Setting button ( ) to adjust the date
and time.
7KH\HDUÀDVKHVRQWKHGLVSOD\
2. SETTING THE YEAR
Press the Date/Time Setting button ( ) to advance by
increments of one year.
Press the Date/Time Setting button ( ) to set the current
year.
7KHPRQWKÀDVKHVRQWKHGLVSOD\
NOTES: ‡7KH\HDUFDQEHVHWEHWZHHQDQG
2030. When the display reaches 2030, it
will return to 2009.
‡3UHVVDQGKROGWKH ) button to
increase the date and time values faster.
3. SETTING THE MONTH
Press the Date/Time Setting button ( ) to advance by
increments of one month.
Press the Date/Time Setting button ( ) to set the current
month.
7KHGD\ÀDVKHVRQWKHGLVSOD\

13

SETTING THE DATE AND TIME
4. SETTING THE DAY
Press the Date/Time Setting button ( ) to advance by
increments of one day.
Press the Date/Time Setting button ( ) to set the current
day.
7KHKRXUÀDVKHVRQWKHGLVSOD\
5. SETTING THE HOUR
The time is set using AM or PM.
Press the Date/Time Setting button ( ) to advance by
increments of one hour.
Press the Date/Time Setting button ( ) to set the current
hour.
7KHPLQXWHÀDVKHVRQWKHGLVSOD\
6. SETTING THE MINUTE
Press the Up button ( ) to advance by increments of one
minute.
Press the Date/Time Setting button ( ) to set the minute
setting.
7. TO TURN THE MONITOR OFF
Press the START/STOP button.

14

SETTING THE ADVANCED POSITIONING SENSOR (APS)
You can change the options for various settings on your monitor. Pressing the SET
button to change a setting. Press the MEM button to select the options for that setting.
$IWHUVHOHFWLQJDVHWWLQJSUHVVWKH67$576723EXWWRQWRFRQ¿UPWKHVHWWLQJDQGWXUQ
the power off.
SETTING THE POSITIONING INDICATOR
1. Select your User ID.
2. Press the SET button.
NOTE:7KHGHIDXOWVHWWLQJLV³RQ´

User A

User B

 3UHVVWKH0(0EXWWRQWRVHOHFWWKH3RVLWLRQLQJLQGLFDWRU³RQ´³RQ´RU³R))´

on1: After the Positioning indicator lights in blue for more than 2 seconds, or
in orange for more than 5 seconds, measurement starts automatically, even
though the monitor is not in the proper position.
on2: The Positioning indicator lights in blue for more than 2 seconds, measurement
starts automatically.
Measurement will not start if it lights in orange.
oFF: Measurement starts without the Positioning indicator.

15

SETTING THE ADVANCED POSITIONING SENSOR (APS)
SETTING FOR RIGHT OR LEFT WRIST MEASUREMENT
1. While in the setting mode, press the SET button until
the wrist symbol ( or ) appears on the display.
127(6 ‡7KHGHIDXOWVHWWLQJLV³ ´
‡$IWHU\RXFKRRVH³R))´IRUWKH
Positioning indicator, the monitor skips
this process.
2. Press the MEM button to select the left wrist ( ) or the right wrist ( ).

SETTING THE BUZZER
1. While in the setting mode, press the SET button until
the buzzer symbol ( ) appears on the display.
NOTE:7KHGHIDXOWVHWWLQJLV³RQ´RU³RQ´
depending on the Positioning indicator you
set.
2. Press the MEM button to select the buzzer setting.

16

SETTING THE ADVANCED POSITIONING SENSOR (APS)
,IWKH3RVLWLRQLQJLQGLFDWRULV³RQ´RU³RQ´
on1: The buzzer sounds only when the monitor is in proper position.
on2: The buzzer sounds a series of two short blips if your wrist is too far away from
the measuring position, and beeps when your wrist is in the proper position.
oFF: The buzzer will not sound.
,IWKH3RVLWLRQLQJLQGLFDWRULV³R))´
on: The buzzer sounds when pressing any buttons.
oFF: The buzzer will not sound.
RESETTING TO THE DEFAULT SETTING
7KHSRVLWLRQLQJLQGLFDWRULVVHW³RQ´WKHZULVWIRUPHDVXUHPHQWLVVHW³ ´DQGWKH
EX]]HULVVHW³RQ´DVGHIDXOW
To reset to the default setting, press and hold the SET button while in the setting mode,
then press the START/STOP button simultaneously for more than 2 seconds.

17

APPLYING THE WRIST CUFF
CAUTION
Read all of the information in the instruction manual and any other
literature in the box before operating the unit.
CAUTION
This device is intended for use in measuring blood pressure and
pulse rate in the adult population. Do not use this device on infants
or persons who cannot express their intentions.
APPLYING THE CUFF ON THE LEFT WRIST
1. Roll up sleeve. Make sure your sleeve is not rolled up too
WLJKWO\RQ\RXUDUP7KLVPD\FRQVWULFWWKHÀRZRIEORRG
in your arm.
2. Wrap the cuff directly against your skin.
Do not apply over clothing. Place the cuff over your left
wrist with your left thumb facing upward.
3. Position the cuff leaving a clearance of approximately 1/2
to 1 inch between the cuff and the bottom of your palm.
4. Hold the bottom part of the cuff and wrap it around the
ZULVWVRLW¿WVFRPIRUWDEO\DQGVHFXUHO\DURXQG\RXUZULVW
NOTE: Make sure the wrist cuff does not cover the
protruding part of the wrist bone on the outside of
the wrist.

18

APPLYING THE WRIST CUFF
5. Fold the remaining part of the wrist cuff back out of the
way.

APPLYING THE CUFF ON THE RIGHT WRIST
When taking a measurement using the right wrist position the
cuff as shown in the illustration.
5HIHUWR³6HWWLQJIRU5LJKWRU/HIW:ULVWIRU0HDVXUHPHQW´

19

TAKING A MEASUREMENT
The monitor is designed to take measurements and store the measurement values in
memory for two people using USER ID A and USER ID B. The monitor can be used to
WDNHDVLQJOHPHDVXUHPHQWXVLQJWKH*8(67PRGHDUHQRWVWRUHGLQWKHPHPRU\
 6LWFRPIRUWDEO\LQDFKDLUZLWK\RXUIHHWÀDWRQWKHÀRRU

2. Select your User ID (A or B).

User A

3. Hold your arm across your chest at heart level.
+ROG\RXUHOERZ¿UPO\WRDYRLGERG\PRYHPHQW
Sit still and do not talk or move during the measurement.

4. When arm is in correct position orange light will turn on.

20

User B

TAKING A MEASUREMENT
5. Press the START/STOP button.
All symbols appear on the display.

7KHFXIIVWDUWVWRLQÀDWHDXWRPDWLFDOO\
$VWKHFXIILQÀDWHVWKHPRQLWRUDXWRPDWLFDOO\GHWHUPLQHV\RXULGHDOLQÀDWLRQOHYHO
7KLVPRQLWRUGHWHFWV\RXUEORRGSUHVVXUHDQGSXOVHUDWHGXULQJLQÀDWLRQ
The Heartbeat Symbol ( ÀDVKHVDWHYHU\KHDUWEHDW
Remain still and do not move until the entire measurement process is completed.
NOTE:7RVWRSWKHLQÀDWLRQRUPHDVXUHPHQWSXVKWKH67$576723EXWWRQ7KH
PRQLWRUZLOOVWRSLQÀDWLQJVWDUWGHÀDWLQJDQGZLOOWXUQRII
5. After the monitor has detected your blood pressure
DQGSXOVHUDWHWKHFXIIDXWRPDWLFDOO\GHÀDWHV
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 30
Producer                        : Mac OS X 10.6.4 Quartz PDFContext
Creator                         : Adobe InDesign CS3 (5.0)
Create Date                     : 2010:09:23 14:19:29Z
Modify Date                     : 2010:09:23 14:19:29Z
EXIF Metadata provided by EXIF.tools

Navigation menu