Ontel 18002 Micro Mechanic User Manual users manual
Ontel Products Corporation Micro Mechanic users manual
Ontel >
users manual
° ° Quick Start Tips 'cr a In. - Micro Mechanic" will only work with vehicles produced 1996 or later. Please check your car's user manual for more details. P d t G ' d - Only operate Micro Mechanic" when in PARK, not in motion and in a well- I'O "C "I e ventilated area if ignition is on. Download an ODBII app for your ms or Android device. a ”"9 your Micro Mechanic" into the 039" For best results, we recommend*: Pfln- PUSh in Until secure. (See fig 3) Turn on your car. Micro Mechanic can only ‘ OBD AUTO DOCTOR operate when vehicle is powered on. - MINI OBDII ' CAR SCANNER ELM OBD2 Open the App you downloaded and follow ‘ CARISTA the prompts to use Micro Mechanic". There . DASHCOMMAND is usually a 'Connect Device” option and/or . TRACKADDICT f‘Diagnose” optign to b: in Ihen, follow . OBD CAR DOCTOR [(réseguléltglelfis as Irecte yt e appt ~ TORQUE 6 When done, store Micro Mechanic" in Find the OBDII port in our car. See Fig 2 for most common included case in a cool, dry area. (See Fig 5) locations and what to 00k for. For more information consult your car's user manual. Need More Help? If you are having issues with setup or connecting to Micro Mechanic", download a different app and repeat setup process. NOTE: The part may be covered by a protective panel or cap. If you require more help setting up your Micro Mechanic", there are several helpful videos available; search OBDII installation in your favorite search engine. We are also here to help - contact us at 855-380-3104 or . micromechaniccs@worldpackusa.com Flg 5 WARNINGS: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this device. To prevent injury or damage to vehicles and/or Micro Mechanic" read this instruction manual first and observe the following safety precautions at a minimum whenever working on a vehicle. SAVE THESE INSTRUCTIONS. - Always perform automotive testing in a safe environment ' Wear safety eye protection that meets ANSI standards. - Keep clothing, hair, hands, tools, test equipment. etc. away from all moving or hot engine parts. . Operate the vehicle in a well-ventilated work area: Exhaust gases are poisonous. - Put blocks in front of the drive wheels and never leave the vehicle unattended while running tests. - Use extreme caution when working around the ignition coil, distributor cap, ignition wires and spark plugs. These components create hazardous voltages when the engine is running. - Put the transmission in PARK (for automatic transmission) or NEUTRAL (for manual transmission) and make sure the parking brake is engaged. . Keep a fire extinguisher suitable for gasoline/chemical/ electrical fires nearby. - Don’t connect or disconnect any test equipment while the ignition is on or the engine is running. - Keep Micro Mechanic" dry, clean, free from oil/water or grease. Use a mild detergent on a clean cloth to clean the outside of the Micro Mechanic", when necessary. SPECIFICATIONS: Supported Protocols OBDII: ISO 157654 CAN 29 bit, 500 Kbaud Communication Method: Bluetooth 20/30] 4.0 SAE J1850 PWM (41 .6Kbaud) ISO 15765-4 CAN 11 bit, 250 Kbaud Software Platform: Supports iOS, Android, SAE J1850 VPW (10.4Kbaud) ISO 15765-4 CAN 29 bit, 250 Kbaud Windows ISO 9141-2 (5 baud init, 10.4 Kbaud) Operating Voltage: 9V—16V ISO142304 KWP (5 baud init,10.4 Kbaud) Operating Current: 50mA ISO 14230-4 KWP (fast init, 10.4 Kbaud) Operating Humidity: (60% ISO 15765—4 CAN (11 bit, 500 Kbaud) Operating Temperature: -30C to 60C *OBD Auto Doctor, Mini OBDII, Car Scanner ELM OBDZ, Carista, Dashcommand, Trackaddict, OBD Car Doctor, Torque do not sponsor, authorize or endorse this product. ”mm” by NOTE: This product ha been tested and round to comply with the limits tor a Class a digital demos, pursuant to Pan is oithe FCC Rules. These lurnis are designed to provide reasonauo protection against nanniui interierence In a residential installation. This product generates. uses and can radiate radio ireouency energy and. ti not inst-led and used in accordance with tho a.“ instructions, may cause hnrrnrui inierierenoo to radio oorriniunicntioris. However. there is no guamriles that tritetfmoo will not occur in u penicular installation. ti the product does cause Wilmium nenriiul lritorlermce to radio or television reception, which can no determined by turning the equipment on and on, me user ie encouraged to try to correct the lnterierertoe by one or more FEW“ NJ mom oiiheiollowinp rrieaeurea: came omd'Pm‘um 0° - War“ or relocate the waiving marina. . - Connect the product into an outlet on ii oireun diiterent horn that to which the reoeiver is oonnected. C M Rights ”served '9' - Increase the swim" between the WWW! and receiver. - Consmt Ihe dealer oran expaienced radio/TV technician tor help. Made '" 5N“ The device complies with Part 15 oi the FCC Hues. Operation is subjecl to the lollowirtg two condilmns: MMlMtot tB—TVP (i) this device may not dame nannlul interterenoe, and let tins device must accept any interterenpe received, including interterenoe that may peuee undesired operation. Foo ID: uomtsooa rec exposure statement rnlr Iqulpm-nt cumpllnwllh l=cc radiation expotur- limit: at ionn ior an uncontrolled onvironm-nt. nut Irnnlmlttlr mud nol lie :n-lncntld nr opoullng In conjunction with any nth-r antenna or lrnnImIIt-r.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 Language : en-US Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Microsoft® Word 2016 Creator : Tsang, Calvin (Hong Kong) Creator Tool : Microsoft® Word 2016 Create Date : 2018:02:15 14:42:55+08:00 Modify Date : 2018:02:15 14:42:55+08:00 Document ID : uuid:98CC3274-6FE4-4890-AD58-2B3A3C5FC159 Instance ID : uuid:98CC3274-6FE4-4890-AD58-2B3A3C5FC159 Author : Tsang, Calvin (Hong Kong)EXIF Metadata provided by EXIF.tools