Opticon Sensors Europe 1989 Handheld RF-ID Tag Reader User Manual Phl27br1

Opticon Sensors Europe BV Handheld RF-ID Tag Reader Phl27br1

Contents

User manual

Download: Opticon Sensors Europe 1989 Handheld RF-ID Tag Reader User Manual Phl27br1
Mirror Download [FCC.gov]Opticon Sensors Europe 1989 Handheld RF-ID Tag Reader User Manual Phl27br1
Document ID318026
Application IDr1hMSZJjth1S0ranSLWVrg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize95.49kB (1193617 bits)
Date Submitted2003-04-15 00:00:00
Date Available2003-04-15 00:00:00
Creation Date2000-11-27 12:52:18
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2000-11-28 10:02:16
Document TitlePhl27br1.qxd
Document CreatorADOBEPS4.DRV Version 4.40
Document Author: kdu

User’s Manual
Laser Terminal PHL 2700
Cradle IRU 2700
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
CAUTION: This user’s manual may be revised or
withdrawn at any time without prior notice.
Limited warranty and disclaimers
By opening the package of this product you agree to
become bound by the liability and warranty conditions as described below.
Under all circumstances this manual should be read
attentively, before installing and or using the product.
In no event, Opticon Sensors Europe will be liable for
any direct, indirect, consequential or incidental damages arising out of use or inability to use both the
hardware and software, even if Opticon has been
informed about the possibility of such damages.
A serial number appears on all Opticon products.
This official registration number is strictly related to
the device purchased. Make sure that the serial number appearing on your Opticon device has not been
removed. Servicing by our Repair Department can
only be carried out under warranty.
All Opticon products are warranted for a period of
one year after purchase, covering defects in material
and workmanship. Opticon will repair or, at its opinion, replace products that prove to be defective in
material or workmanship under proper use during
the warranty period.
Opticon will not be liable in case modifications are
made by the customer. In such case the standard
repair charge will be applicable. The standard charge
for repair will also be applicable in case no defect is
found at all. These rules also apply for products that
are still under warranty. Therefore, you are advised to
have the product specifications always at hand.
Trademarks used are property of their respective
owners
PHL2700
TERMINAL
/ IRU2700
CRADLE
CONTENTS
Copyright 2000, Opticon Sensors Europe B.V.
All rights reserved.
This manual may not, in whole or in part, be copied,
photocopied, reproduced, translated or converted to
any electronic or machine readable form without
prior written consent of Opticon Sensors Europe.
MANUAL
page
page
INTRODUCTION
PIN OUT
17
INSTALLATION
2.1
UNPACKING
5.1
5.2
5.3
RS232 cable for terminal
RS485 cable for cradle network
RS232 cable for cradle
17
17
17
2.2
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
DETAILED VIEW
Dimensions of terminal
Details of terminal
Display of terminal
Dimensions of cradle
Details of cradle
SPECIFICATIONS
18
2.3
HANDLING
6.1
6.1.1
6.1.2
6.1.3
6.1.4
6.1.5
6.1.6
SPECIFICATIONS TERMINAL
Electrical specifications
Optical specifications
Physical specifications
Functionality
Environmental specifications
Supported Barcode symbologies
18
18
18
18
18
19
19
2.4
2.4.1
2.4.2
2.4.3
ASSEMBLY
Terminal
Cradle
Terminal on cradle
2.5
INSTALLING,
6.2
6.2.1
6.2.2
6.2.3
6.2.4
SPECIFICATION CRADLE
Electrical specifications
Functionality
Environmental specifications
Physical specifications
19
19
19
19
19
TROUBLESHOOTING
20
7.1
7.2
7.3
COMMUNICATION PROBLEMS
READ OPERATION PROBLEMS
TERMINAL PROBLEMS
21
21
21
PRODUCT ORDERING
INFORMATION
23
PRECAUTIONS
10
REPLACING AND CHARGING
10
Required batteries
11
How to charge the rechargeable
battery pack in the cradle?
11
When to replace or recharge the
main battery?
11
When to replace the backup
battery?
11
How to (re)place the main battery
in the terminal?
12
How to (re)place the backup battery
in the terminal?
13
BATTERIES
2.5.1
2.5.2
2.5.3
2.5.4
2.5.5
2.5.6
2.6
2.6.1
2.6.2
2.6.3
2.6.4
INSTALLING IN A SYSTEM
Terminal to computer
Single cradle to computer
Cradle network
Dip switch settings on cradle
14
14
14
14
15
OPERATION OF THE TERMINAL 15
SCANNING
16
4.1
4.2
How to read the barcode
Barcode reading problems
16
16
The general use and functioning of the
terminal together with the cradle will be
described in this manual.
The exact behavior of the terminal
depends on the user application that is
running. For instructions about applications
please consult the documentation of
that software.
INTRODUCTION
This terminal is a compact, programmable
handheld terminal, and is well suited for a
variety of indoor portable applications. It has a
built-in laser scanner that can scan all popular
bar code labels at varying distances.
User’s applications can be downloaded to the
terminal to adapt the terminal to the user’s
situation.
Operating power is supplied by the main
battery. The main battery may consist of a
rechargeable Ni-MH battery pack (to be
charged in cradle), or dry cell batteries, either
non-rechargeable or rechargeable (to be
charged in external charger).
The cradle is a communication station for data
transmission between the (host) computer
system and the terminal. It communicates with
the terminal through their IrDA interface. The
cradle will also charge the rechargeable
battery pack in the terminal through the
electrical contacts.
The IrDA interface on the terminal enables
you to communicate with other devices that
use IrDA communication, like portable
computers, notebooks and organisers.
Additional a RS232 cable can be used.
The RS232 cable can be used for direct
communication between the (host) computer
system and the terminal, for example to
download software to the terminal.
Please read this manual carefully
before using the terminal, to maximise
the efficiency of this terminal.
Opticon user's manual
PHL2700-barcode-ver1-00 / printed 11 00
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
2.1 UNPACKING
66mm
41mm
Apart from the terminal or cradle, additional
items might be ordered and supplied.
If there are any missing parts please contact
your supplier.
31mm
INSTALLATION
2.2.1 Dimensions of terminal
53mm
177mm
TERMINAL
PHL2700:
ADDITIONALS
PHL2700:
Package contents:
Battery Pack
for terminal
Contents:
Battery case
Terminal
Dry cell batteries
Do not remove the label !
On the back of every unit you will find a label.
The label is attached by the manufacturer and
includes information about the function it
supports and a serial number. Do not remove
it.
CRADLE
IRU 2700:
ADDITIONALS
IRU2700:
Cradle
Power Supply
for cradle
2.2.2 Details of terminal:
Battery Pack
for terminal
rechargeable battery
pack
Cable for cradle
RS232 cable DB9 F
Backup battery
Handstrap
Cable for terminal
RS232 cable
PHL2700
TERMINAL
/ IRU2700
CRADLE
1. Reading window
laser beam for barcode reading will be
emitted from here
2.2 DETAILED VIEW
When you remove the packing, please check
for any physical damage. We recommend that
you save all packing material, as it should be
used whenever you need to ship your terminal
(eg. for service). Damage due to improper
repacking is not covered by the warranty.
MANUAL
2. LCD Display
for displaying information
3. LED indicator
can be used to indicate results, for example
bar code reading / status of communication
4. Power key
for switching power On/Off
5. Trigger key definable by user’s application
typical use: read key, switches laser beam
on for barcode reading
6. Quick keys definable by user’s application
typical use: menu scroll keys or yes/no input
7. Control keys definable by user’s application
for controlling basic functions
typical use as below:
CLR : Cancel input
BS : Back space
: Shift key
“S”on the LCD display indicates
the terminal is in the shift mode
8. Character keys definable by user’s application
typical use: for input of alpha-numeric and
punctuation characters
9. ENT key definable by user’s application
typical use: for confirming input
10. Function keys definable by user’s application
user programmable keys, to be used
together with shift key.
typical use as shown on next page
10
11. Battery case cover
for housing main battery
11
12. Optical interface window
for infra red communication
13. Hand strap pillar
for attaching hand strap
Cable for cradle
RS485 network cable
12
15 14
13
14. Electrical contacts
for power supply from the cradle IRU2700
to terminal
15. RS-232C connector
for connecting external device, or for system
expansion, through Opticon RS232 cable
Opticon user's manual
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
Description of the function keys
2.2.3 Display of terminal
In the shift mode, back light on/off, contrast
adjustment, and cursor movement can be
done by these keys.
(The user’s application can give different
definitions to the keys)
The liquid crystal display of the terminal is
typically used to show program prompts,
instructions and data, as defined in the user’s
application.
81mm
TERMINAL
/ IRU2700
CRADLE
90mm
150mm
Special purpose symbols in display:
input minus sign
delete one character
input space
toggle with back light
move cursor
adjust contrast
PHL2700
2.2.4 Dimensions of cradle
The display has the following default options:
shift mode
functions:
F1 (-)
F2 (DEL)
F3 (SP)
F4 (BL)
F5 (<--), F6 (-->)
F7 ( ), F8 ( )
MANUAL
The symbols will be shown in the bottom part
of the display and indicate status.
2.2.5 Details of cradle
1. DC input socket
input for AC adaptor
2. RS 485 socket
for connecting another cradle in multi-drop
RS485 network, through Opticon RS485
cable
Description of the display indicators
3. RS 232 C socket
for connecting to PC or modem, through
Opticon RS232 cable
Main Battery indicator
Off: Sufficient battery power
On: Battery low.
Replace battery immediately.
4. Switch for terminal detection
to detect if a terminal is placed on the
cradle
Backup Battery indicator
Off: Sufficient battery power
On: Battery low.
Replace battery immediately.
5. Electrical contacts
for power supply to terminal PHL2700
If rechargeable Ni-MH battery pack is
inserted in the terminal the pack will be
charged through the electrical contacts
Alpha mode on
(Shift-key activated)
6. DIP switches
setting parameters of the infrared interface
switches are located behind the cover
7. Optical window
window for optical data transmission
Backlight
The display is provided with a backlight.
When the backlight is turned on, the power
consumption increases. To extend the life time
of your batteries use the backlight as little as
possible.
8. LED indicator
indicating power
LED on:
power is on
LED off:
power is off
Opticon user's manual
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
2.3 HANDLING PRECAUTIONS
Use of the terminal
Operate the terminal keys by
pressing them lightly with your
fingertips or with something soft
and round.
Pressing the keys with a sharp
pointed object (for eg. a ballpoint) can damage the keys.
To avoid malfunctioning and to ensure years
of trouble free operation, pay attention to the
following:
General use
Do not use or leave the product
in extremely hot areas - like
direct sunlight, near a heater,
or in a car - or in areas that are
very cold, humid, moistured or
dusty.
Do not subject the the product
to very strong impact, do not
throw or drop the terminal from
large heights.
Clean the exterior by wiping it
with a soft, dry cloth. Do not
use much water.
Do not use thinner, white spirit
or other solvents. These can
discolour the case and the keys
and has a negative effect on
the lifetime of the keys.
TERMINAL
/ IRU2700
CRADLE
2.4.2 Cradle
2.4 ASSEMBLY
Place for mounting
Follow the next steps to make your terminal
ready for installation in a system, that is
described further in the manual.
2.4.1. Terminal
Place the cradle in normal office
conditions.
Avoid a place under strong light.
Otherwise IrDA communication may be
disturbed.
Power Connection
Fix the small cord of the strap around the
pillar of the terminal (ref. 1)
Insert the handle of the strap in the thin
loop (ref. 2)
The strap is fixed to the terminal (ref. 3)
Hold the handstrap around the wrist when
carrying the terminal (ref. 4)
Do not swing the terminal around.
Do not leave the terminal in an
area where static charge is
accumulated, or near devices
where electromagnetic emission
is generated.
Do not allow a mechanical
shock to the product.
General cleaning instructions
PHL2700
To avoid drop use the hand strap.
Avoid temperature changes.
Sudden temperature changes
can cause condensation to
form on the terminal. Using the
terminal while condensation is
present can cause malfunction.
Always wait until the condensation
clears naturally before attempting
operation.
Do not expose the product to
rain or water splash
MANUAL
Do not place any objects on top
of the terminal. Do not lay the
terminal face down.
Doing so can cause accidental
operation of the [PW] key or
[ENTER] key, which can discharge your batteries or
change settings you do not
want to be changed.
Attach the DC jack of the AC adapter
into the socket of the cradle.
Then connect the AC adapter to the
mains outlet
When the terminal PHL2700 with the
rechargeable battery pack is placed in
the cradle, the LED on the cradle turns
green.
When the terminal PHL2700 with
penlite batteries is placed in the cradle, no
indication is given by the cradle.
2.4.3. Terminal on cradle
Take notice that the IRU2700 cradle is designed
for the PHL2700 terminal. No other types of
terminals can be placed into this cradle.
Place the terminal in the cradle as shown in
the illustration:
Cleaning of the terminal
Clean the optical interface window periodically.
Maintenance
Use of the cradle
Do not place any other product than the
PHL-type terminal in the cradle.
Cleaning of the cradle
Avoid touching the contacts in the cradle. The
contacts must stay as clean as possible to
maintain optimal charging capacity.
Do not use water when cleaning the cradle.
This can cause malfunction in the chargers.
There are no user-serviceable
parts inside the terminal or the
cradle. So do not try to take it
apart. The manufacturer will not
be liable for any damage
caused by the customer.
In case of malfunction that can not be solved
by the trouble-shooting instruction in the
appendix, please consult our service
department.
Start with a full battery
To be sure of proper operation, it is
advised to start with a full battery,
charge the battery pack according to the
instructions in the next chapter.
Click the battery pack into the terminal,
as instructed in the next chapter.
Opticon user's manual
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
2.5 INSTALLING, REPLACING
AND CHARGING BATTERIES
2.5.1 Required batteries
The terminal needs both main battery and
backup battery for operation.
Wrong use of batteries might cause
serious damage
to the terminal or to the cradle.
Insert full batteries before use of the
terminal.
Never remove the main battery pack
while the terminal is turned on.
Doing so can cause data in the terminal
to be deleted.
When you do not use the terminal for
a long time, make sure the main
battery has enough capacity.
When there is not enough capacity the
backup battery will be used up.
Rechargeable Opticon battery pack (NiMH),
to be recharged when placing the terminal
PHL2700 in the cradle IRU2700.
Only use recommended batteries.
When other batteries are used, defects or
other problems can occur. Before installing
(new) batteries, please make sure you are
using the recommended batteries.
Follow the instructions for installing,
changing and removing the batteries
very strictly.
The products are not warranted for
damage, defects, malfunction or loss of
data, resulting from incorrect use of
batteries.
TERMINAL
/ IRU2700
CRADLE
Make sure that the Opticon rechargeable
battery pack (Ni-MH) is inserted in the
terminal.
If the terminal with the right rechargeable
battery pack is placed in the cradle, the
LED on the cradle will turn green.
The rechargeable battery pack inside the
terminal will be charged automatically for
a period of 8 hours when the terminal is
placed in the cradle.
Dry cel Opticon batteries (Alkaline).
To be used together with Opticon battery
case for dry cell batteries.
These batteries are not rechargeable.
Do not make a mistake regarding the
polarity (+ , -) of the battery.
The terminal will not work when the
polarity is incorrect.
Use the right charger for batteries
Only the rechargeable Ni-MH battery
pack of Opticon can be charged inside
the terminal in the cradle IRU2700. Other
rechargeable batteries need to be
recharged in a separate battery charging
device.
PHL2700
2.5.2 How to charge the rechargeable
battery pack in the cradle?
Main Battery
The main battery can consist of:
In order to avoid damage
it is very important to take notice
of the instructions.
MANUAL
When the battery case with penlite
batteries is inserted in the terminal, it will
not be charged by the cradle.
If the terminal with penlite batteries is
placed in the cradle, the cradle will not
show an indication.
2.5.3 When to replace or recharge the
main battery?
Other batteries. All batteries have to be
used together with Opticon battery case
for dry cell batteries.
Batteries that are not supplied by Opticon
must be AA-size and absolutely leakproof.
If rechargeable batteries are used, they
need to be recharged by a separate
battery charging device.
Opticon recommends to use Opticon batteries
(Opticon rechargeable battery pack or Opticon
dry cell batteries) only.
Backup Battery
Use only one type of battery for backup:
Backup battery:
CR2032 Li (Lithium, button type).
There are 2 reasons for replacing the main
battery;
as soon as possible after the battery
indicator
appears on the display.
when you are not using the terminal for an
extended period.
For instructions of (re)placing the main battery
see paragraph 2.5.5.
2.5.4 When to replace the backup battery?
When low battery mark
appears,
replace the battery without delay.
For instructions of (re)placing the backup
battery see paragraph 2.5.6.
Opticon user's manual
10
11
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
2.5.5 How to (re)place the main battery
in the terminal?
USER’S
CRADLE
MANUAL
PHL2700
TERMINAL
/ IRU2700
CRADLE
2.5.6 How to (re) place the backup battery
in the terminal?
----> open
Only use batteries as specified in
paragraph 2.5.1.
If you have data stored, make sure the
backup battery is placed and full
enough, to avoid data loss.
Before installing a battery case with penlite
batteries:
Make sure you use the right battery size.
Place 2 batteries in the battery holder
aligning plus (+) and minus (-) ends as
shown on the battery holder.
Make sure that the main battery
is full enough while changing the
backup battery.
Only use CR2032 Li
(Lithium, button type) battery.
close <----
Unlock cover: Open the switch (shift to
the right) and remove the battery case
cover (ref. 1)
Open lid: Place your thumbnail below the
saving of the lid to open it (ref. 5)
Remove backup battery: Take the old
battery out of the compartment.
Place backup battery: Make sure that the
positive side of the backup battery is
pointed upwards and place it in the
compartment (ref. 6)
Close lid: Press the lid downwards until it
clicks into the compartment
Fit cover: Place the battery case cover and
lock the switch (shift to the left)
(ref. 1)
The instructions for installing the rechargeable
battery pack are also applicable for the battery
case with penlite batteries.
Unlock cover: Open the switch (shift to
the right) and remove the battery case
cover (ref. 1)
Remove main battery: Hold the battery
case while pressing on both sides and lift
it (ref. 2)
Place main battery: Take the battery case.
Check if the charging contacts of the case
align with the contacts inside the battery
compartment (ref. 3)
Fit main battery: First press the pack
into the direction of the terminal nose.
Than press the pack tight into the housing
untill it cliks (ref. 4)
Fit cover: Place the battery case cover and
lock the switch (shift to the left)
(ref. 1)
Opticon user's manual
12
13
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
2.6 INSTALLING IN A SYSTEM
2.6.1 Terminal to computer
PHL 2700
Turn off your devices before
installation.
Because of the special pin-out of the
connectors, use the cables supplied
by the manufacturer.
When you need another cable for a
certain device, that is not supplied,
contact your supplier to purchase the
right cable. In case another cable is
used, take notice of the pin-out
specifications further in this manual.
3 POLE
CONNECTOR
RS 232
2.6.2 Single cradle to computer
DB25 / DB9
HOST
DB9
CRADLE
TRANSMISSION
HOST
RS 232
TERMINATED RS 485
sw 1 = on
sw 2 = on
sw 3 = on
Open the cover of the DIP switches on the
bottom of the cradle in order to reach the
DIP switches.
Turn the DIP switch ON by moving it
upwards into the direction of the dipswitch
number.
Turn the DIP switch OFF by moving it
downwards into the direction OFF.
DIP
SWITCH
FUNCTIONS
ON
OFF
DEFAULT
SW 1
RS 232
CONNECTION
in use
not
in use
ON
SW 2
RS485
TERMINATOR
in use
not
in use
OFF
SW 3
RS485
TERMINATOR
in use
not
in use
OFF
SW 4
BAUDRATE *
--
--
OFF
SW 5
BAUDRATE *
--
--
OFF
SW 6
BAUDRATE *
--
--
ON
SW
SW
SW
1200
OFF
OFF
OFF
2400
ON
OFF
OFF
4800
OFF
ON
OFF
9600
*)
BAUDRATE
ON
ON
OFF
19200 (default)
OFF
OFF
ON
38400
ON
OFF
ON
115200
OFF
ON
ON
ON
ON
ON
NONE
//
/ IRU2700
CRADLE
RS 485 TERMINATED
sw 1 = off
sw 2 = on
sw 3 = on
OPERATION OF
THE TERMINAL
The functionality of the terminal is determined
by software, the so-called user application,
that is running on the terminal.
Usually, the terminal is not equipped with
software and has no functionality. At first the
user application must be loaded before the
terminal can be used for barcode scanning.
RS 232
Connection sequence
for cradle in network:
Set all cradles to the same baud rate (by
DIPswitch)
Only 1 cradle in the network will be
connected to the PC through one RS232
cable. On this cradle the DIPswitch for RS232
connection must be enabled. Through this
connection all cradles can communicate to
the PC.
A maximum of 16 cradles can be connected
in a network through RS485 cables. For the
cradles that are not directly connected to the
PC the DIPswitch for RS232 connection
must be set to off.
The first and the last cradle in the network
must have the termination resistors set by
dipswitch.
RS 485
sw 1 = off
sw 2 = off
sw 3 = off
TERMINAL
Setting the DIP switches on or off will result in
differrent baudrates and enabled or disabled
functions of the cradle.
2.6.3 Cradle network
Connection sequence
for single cradle:
Place the cradle in normal office conditions,
avoid a place under strong light.
Disconnect the power supply.
Set the required DIPswitches for
baud rate and function.
Connect the interface cables.
Connect the power supply.
Place the PHL2700 terminal in the cradle.
PHL2700
2.6.4 DIP switch settings on cradle
DB9
HOST
Exercise caution at all times when
working with AC-powered equipment.
MANUAL
Tools for developing a user application on the
PC for use on the terminal, as supplied by
Opticon are:
Application Generator
PotStar (Limited or Professional)
C language: Microtec ANSI-C compiler
and C library for handheld terminals.
The user application must be downloaded
from the PC into the terminal. You can use the
cradle, an RS232 cable or an infrared adapter
for communication between the terminal and
the PC. A program on the PC will send the
user application to the terminal, where it is
stored in FlashROM memory.
When the functionality of the terminal is defined
by the application it is ready for operation.
In a typical application you will press the trigger
key and scan a bar code label as described in
the next chapter. Scanned data and data
entered from the keyboard is stored in the
terminal's RAM. The user application can use
this data in subsequent steps.
The collected data can be transmitted to the PC
for further processing. For data transmission
you can use the cradle, an RS232 cable or an
infrared adapter to connect the terminal to the
PC.
Opticon user's manual
14
15
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
SCANNING
MANUAL
PHL2700
Fit the bar code in the laser beam from
margin to margin and pass the scanner
downward over the bar code, as shown in the
scan position illustration.
5.2 RS485 cable for cradle network
IRU2700
Please make sure that the terminal is
installed according to the installation
instructions.
4.1 How to read the barcode
The scanning sequence is defined by the
user’s application. A typical sequence is:
Press the [PW] key to turn power on.
Check the display for the message:
READ BAR CODE
Point the terminal to the barcode and
press the Trigger key.
Point the laserbeam to barcode as shown
in the scan position illustration.
The barcode will be read and the reading
results will be indicated.
A ‘Good Read’ means that the scanner has
effectively recognised and decoded the bar
code. In most cases, the application program
will provide an indicator signal or a buzzer
signal to indicate a good read to the user.
When the read is incorrect you can try again,
paying attention to the instructions in this
chapter.
CRADLE
PIN-OUT
5.1 RS232 cable for terminal PHL1700
Please take care of the handling
precautions.
Never remove the main battery pack
while the terminal is turned on.
Doing so can cause data in the terminal
to be deleted or corrupted.
/ IRU2700
The terminal is a Class I laser product
conforming to the strictest laser safety
standards. However, we recommend that
you avoid looking directly into the laser
beam emitter, or pointing the laser beam
directly into someone’s eyes.
TERMINAL
incorrect read
scan positions
RS232
cable
5.3 RS232 cable for cradle IRU2700
good read
scan position
When reading a small bar code, decrease the
distance between the terminal and the bar code.
For larger bar codes, position the terminal so
that the bar code fits into the laser beam.
When reading a very high density bar code,
decrease the distance between the terminal
and the bar code. For a low density bar code,
increase the distance between the terminal
and bar code.
5.1
Jack
plug
Signal
3 pole
(terminal)
DB 9
connector
Female
(PC)
TxD
RxD
GND
5.2
Network
cable
RS485
Signal
RxD
TxD
GND
Modular
plug
(6P6)
Modular
plug
(6P6)
Signal
RD+
RDSD+
SD-
4.2 Barcode reading problems
When the barcode can not be read, try the
following:
Change the angle between the bar code
and the terminal.
Change the distance between the bar
code and the terminal.
If the bar code is larger than the laser
beam, try moving the terminal a bit further
away from the bar code.
5.3
RS232
cable
DB 9
DB 9
male
Signal female
(cradle)
(PC)
6+1
TxD
RxD
DSR
GND
DTR
CTS
RTS
6+1
Signal In/Out Note
(cradle)
RxD
TxD
DTR
GND
DSR
RTS
CTS
IN
OUT
OUT
OUT
ON (fixed)
not used
ON (fixed)
not used
Opticon user's manual
16
17
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
6.1.2 Optical specifications
Light source
650 nm visible laser diode
Scan rate
100 scans/sec
Decode rate
100 decodes/sec
Reading width
62 mm at 30 mm
111 mm at 100 mm
Transmission speed
RS232 direct cable:
2400 - 115200 baud
RS232 cradle:
2400 - 115200 baud
IrDA terminal:
2400 - 115200 baud
MANUAL
PHL2700
0 - 140 mm
(at PCS 0.9, res. 0.25)
SPECIFICATIONS
6.1 SPECIFICATIONS TERMINAL
6.1.1 Electrical specifications
Main battery
Main battery
operating time
Backup battery
Backup battery
operating time
rechargeable pack: Ni-MH
dry cell: Alkaline penlite
optional: other 2 x AA-size
penlite
Ni-MH: When making every 5
seconds 1 scan with 1 sec
laserbeam on and 0.2 sec.
green LED on and 0.2 sec.
buzzer on, operating time is:
approx. 40 hours
Alkaline: When making every
5 seconds 1 scan with 1 sec
laserbeam on and 0.2 sec.
green LED on and 0.2 sec.
buzzer on, operating time is:
approx. 78 hours
Different operation conditions
affect the operating time
Use of other penlite batteries
affect the operating time
Lithium (CR2032)
6.1.3 Physical specifications
Humidity
(non condensing)
Dimensions (l x w x d)
177 x 62 x 41 mm
Shock: drop:
1.5 m drop onto concrete surface
Case material
ABS
Shock: vibration:
Weight
body (excl. battery): 175 g
10 - 50 Hz with 1G for 30 min,
cycle for X,Y,Z.
Direct cable (optional)
RS232 - DB9 female
6.1.4 Functionality
Memory
ROM: 32 kB
FlashROM (for O/S and
program): 512 kB
fast RAM: 2kB
battery backed up D-RAM
(for data): 8 MB
Microprocessor
16-bit
Real time clock
Quartz RTC, time and date
programmable, leap year
handling, (accuracy + 60
sec./month)
Display
with backlight
128x64 Pixels graphic LCD
Character fonts:
4/8 lines x 16 characters
5/10 lines x 21 characters
Keyboard
27 keys total
(26 keys user definable)
8 Function keys
Alpha/Numeric mode
If fully charged: 30 days backup
time
Battery
management
Low voltage indicated on the
terminal display.
When battery is low the
terminal switches off
automatically.
Trigger mode
Manual
Programming
Functionality is provided by
user application. The application
may be downloaded from PC
via cable, com port or IrDA.
Charging method
Rechargeable Ni-MH pack in
terminal via cradle
Interfaces supported
Ambient light
rejection
20 - 80 % in operation
20 - 90 % in storage
fluorescent 3.000 lux max.
direct sun 50.000 lux max.
Emission
According to EN50081, part 1
Immunity
According to EN50082, part 1
CRADLE
6.2.1 Electrical specifications
Battery charging time
6.1.5 Environmental specifications
Temperature
0 - 50 oC in operation
-10 - 60 oC in storage
/ IRU2700
6.2 SPECIFICATIONS CRADLE
Resolution at PCS 0,9 0.15 mm (6mil)
Depth of field
TERMINAL
when battery in terminal:
8 hours charge
6.2.2 Functionality
Interfaces supported
RS232
RS485
Serial communication
RS232 Baudrate:
1200 - 115200
RS485 Baudrate:
1200 - 115200
Transmission modes
Half duplex RS232
Half duplex RS485
Parity
Odd, Even, None
Protection against
dust and moisture According to IEC529, IP 42
Safety, Laser class According to IEC825,
Class I laserproduct
6.2.3 Environmental specifications
Temperature
0 - 40 oC in operation
-20 - 60 oC in storage
Humidity
(non condensing)
6.1.6 Supported symbologies
Chinese Post 2of5
Codabar incl. ABC and CX
Code 39
Code 93
Code 128
EAN-8 incl. +2,+5
EAN-13 incl. +2,+5
IATA
Industrial 2of5
Interleaved 2of5
Italian Pharmaceutical
Laetus
Matrix 2of5
MSI/ Plessey
UK/ Plessey
S-Code
Telepen
UPC-A incl. +2,+5
UPC-E incl. +2,+5
30 - 85 % in operation
30 - 90 % in storage
Shock: vibration:
cycle for X,Y,Z.
10 - 50 Hz with 1G for 30 min,
Emission
According to EN50081, part 1
Immunity
According to EN50082, part 1
6.2.4 Physical specifications
Dimensions (l x w x d)
150 x 90 x 81 mm
Case material
ABS
Weight
250 g
Standard connector
RS232 - D Sub 9P Female
RS485 - 6 pins modular plug
RS232 by direct cable
RS232 by cradle
IrDA on terminal
Opticon user's manual
18
19
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
MANUAL
7.1 COMMUNICATION
PROBLEMS
No communication from the cradle to the
device, or data is transmitted distorted or
corrupted.
TROUBLE
SHOOTING
This chapter contains information on solving
problems you may encounter when using the
terminal and/or cradle. If problems occur, first
carry out some general checks, before
verifying the problem with the descriptions in
this chapter.
General checks:
Make sure everything is installed properly
Check the power supply of all devices
Is the reading window of the terminal clean?
Is the optical window of the cradle clean?
Are the bar code labels readable, eg. not
damaged or poorly printed?
Power indicator of the cradle is not green.
Check if the battery case cover of the
PHL2700 is closed properly.
Clean the optical interface window of the
cradle and/or terminal, and try again.
Check all cables.
When the power indicator is still not
green, the cradle needs service.
No data transmitted
The cradle will only work if connected to
a PC.
Clean the optical interface window of the
cradle and/or terminal, and try again.
If the equipment still does not work after these
checks have been performed, please verify if
one of the problems described in this chapter
applies to the problem you have with the
scanner.
Data is corrupted, or no data is
transmitted.
Is the proper baudrate selected?
The computer needs the same baudrate
as the terminal.
Clean the optical interface window of the
cradle and/or terminal, and try again.
It is possible that you may not solve the
problems, despite our descriptions. In this
instance, please contact your dealer or
Opticon.
The terminal looses data when the battery
pack is removed for a short period.
When the terminal needs to be repaired,
please ensure that the label with the serial
number is still present. If sending the terminal
or cradle, please use the original packing to
minimise the chances of damage.
/ IRU2700
CRADLE
When the terminal has a problem with
reading the label:
TERMINAL
7.2 READ OPERATION
PROBLEMS
PHL2700
The resolution of the bar code is too
high.
Decrease the distance between the bar
code and the terminal.
The angle between the label and the
terminal is too high.
Change the angle between the bar code
and the terminal.
The distance is too far or too close.
Change the distance between the bar
code and the terminal.
The bar code is larger than the laser
beam.
Try moving the terminal a bit further away
from the bar code.
The read window is dirty.
Clean the read window of the terminal.
The type of the bar code label is not
enabled.
Enable the bar code symbology in the
application program.
The backup battery is empty.
Replace the Lithium CR2032 battery by
a new one.
Opticon user's manual
20
21
USER’S
MANUAL
PHL2700
TERMINAL
/ IRU2700
USER’S
CRADLE
MANUAL
PHL2700
TERMINAL
/ IRU2700
CRADLE
7.3 TERMINAL PROBLEMS
Terminal does not respond to key presses,
while the display stays on.
Message “Application halted” or
“No application installed” is shown.
There is no user’s application for PHL2700
loaded in the terminal. Contact your
supplier.
For example pressing the shift key does
not toggle the shift indicator.
There is a flaw in the application program.
Disconnect the battery pack, and place it
then back in.
The terminal will be in off-state.
Activate the system menu and restart the
application, or download new application.
If problems appears continously contact
the supplier of the user’s application.
Terminal gets no power, when pressing the
powerkey.
The main battery is exhausted.
Replace the battery pack, or charge the
terminal in the cradle.
Apart from the terminal, additional items
might be ordered.
Terminal does still not operate and needs a
service
Send the terminal to your supplier for service,
paying attention to the limited warranty.
Apart from the cradle, additional items
might be ordered.
Article Code
Terminal
PHL 2700-80 (8MB)
Cable for terminal
RS232 cable DB 9 female
Article Code
Cradle
IRU2700-S
O2540000015
Power supply for cradle
9V DC adaptor
A50200N0020
A73800R0040
Battery pack for terminal
Rechargeable Battery Pack O2540000020
Dry Cell Battery Pack Assy O2510000030
(assy = case holder + penlite batteries)
Battery Case Holder
Q2510000040
Penlite Batteries
PBA30000010
Laser stays off, when pressing the
triggerkey.
PRODUCT
ORDERING
INFORMATION
Cables for cradle
RS232 cable DB 9 female
Adapter
DB25 female/DB9 male
RS485 cable
O2520000020
P10AT000040
O2520000050
O2500000050
Protective bags for terminal
Leather bag
O2510000055
Leather bag clip
O2510000060
Power is off.
The triggerkey is no powerkey. Press the
powerkey to get power.
If the terminal is not used the scanner will
switch off all functions.
Press the powerkey to reactivate.
Software development tools
Microtec
ANSI-C cross compiler
C-library for
handheld terminals
Application Generator
Potstar Limited
Application Generator
Potstar Professional
Laser temperature has become too high.
The laser is switched off automatically,
when thelaser temperature becomes
above 50oC. Wait until the temperature
has dropped.
O8010000010
D4030000020
D6010000010
D6020000010
Opticon user's manual
22
23
Opticon Article Code
O0220000022
Opticon user's manual
24

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2000:11:27 12:52:18
Producer                        : Acrobat Distiller 4.05 for Windows
Author                          : kdu
Creator                         : ADOBEPS4.DRV Version 4.40
Title                           : Phl27br1.qxd
Modify Date                     : 2000:11:28 10:02:16+01:00
Page Count                      : 13
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q2Q-1989

Navigation menu