Oregon Scientific Global Distribution SE11-01 jumbo wall clock User Manual
Oregon Scientific Global Distribution Limited jumbo wall clock Users Manual
Users Manual

EN
1
Jumbo Wall Clock
Model: JW108
USER MANUAL
JW108_M_EN.indd 1 14-7-10 1:27

EN
2
Jumbo Wall Clock
Model:JW108
USER MANUAL
CONTENTS
Overview ..................................................................... 3
Front View ............................................................... 3
Rear View ................................................................ 3
Remote Sensor ....................................................... 4
Getting started ........................................................... 4
Insert Batteries ........................................................ 4
Remote Sensor .......................................................... 4
Sensor Data Transmission ...................................... 5
Clock ........................................................................... 5
Clock Reception ...................................................... 5
Set The Clock Manually .......................................... 6
Weather Forecast ...................................................... 6
Temperature ............................................................... 6
Precautions ................................................................ 7
Specications ............................................................ 7
About Oregon Scientic ........................................... 8
EU - Declaration Of Conformity ................................ 8
FCC Statement ........................................................... 9
Declaration Of Conformity ...................................... 10
JW108_M_EN.indd 2 14-7-10 1:27

EN
3
OVERVIEW
FRONT VIEW
1
2
7
8
6
34 5
1. Current time, weather display
2. Current weekday display
3. Current date display
4. Current indoor temperature reading
5. Current outdoor temperature and sensor
reception indication
6. : Main unit low battery display
7. : Outdoor remote sensor low battery display
8. : Clock signal reception indication
REAR VIEW
11 12 13
9
10
14
15
16
17
18
9. Battery compartment
10. Battery compartment door
11. : Manually adjust current time and date
12. +/- Increase/decrease settings
13. SENSOR: Enable/disable searching sensor signal
14. Wall mounting hole
15. EU/UK/US: Slide to select desired clock reception;
time and date setting
16. °C/°F: Slide to select desired temperature unit
17. RCC: Enable/disable clock signal reception
18. RESET: Reset the unit to default settings
JW108_M_EN.indd 3 14-7-10 1:27

EN
4
REMOTE SENSOR
20
23
21 1 2 3
Reset 22
19
19. LED status indicator
20. Wall mount hole
21. CHANNEL switch
22. RESET: Reset the unit to default settings
23. Battery compartment
GETTING STARTED
INSERT BATTERIES
1. Remove the battery compartment.
2. Insert the batteries, matching the polarities (+/-).
3. Press RESET after each battery replacement.
LOCATION MEANING
Clock/alarm area Main unit batteries
low
Outdoor temperature
area
ensor batteries low
REMOTE SENSOR
The main unit can collect data from up to 1 sensor.
To set up the sensor:
1. Open the battery compartment.
2. Slide the CHANNEL switch to 1, then press RESET.
3. Close the battery door.
4. Place the sensor within 98 ft (30 m) of the main unit
using the wall mount.
TIP Ideal placements for the sensor would be in any
location on the exterior of the home at a height of not
more than 5 ft (1.5 m) and which can shield it from direct
sunlight or wet conditions for an accurate reading.
JW108_M_EN.indd 4 14-7-10 1:27

EN
5
The sensor reception icon in the remote sensor area
shows the status:
Screen display Description
Main unit is searching
for sensor(s).
The channel has been
found.
The sensor cannot be
found.
TIP The transmission range may vary depending on
many factors. You may need to experiment with various
locations to get the best results.
CLOCK
CLOCK RECEPTION
This clock is designed to synchronize its clock
automatically with a clock signal.
Slide to select the desired region (EU/UK/US).
Region Signal
EU DCF
UK MSF
US WWVB
1.5m
(5ft)
NOTE Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures
below freezing.
SENSOR DATA TRANSMISSION
To search for a sensor:
Press and hold SENSOR. Press and hold again to
stop searching.
JW108_M_EN.indd 5 14-7-10 1:27

EN
6
Clock signal reception indicator:
Screen display Description
Searching for clock
signal reception
Excellent signal
Weak signal
No clock signal
reception
NOTE It takes 2-10 minutes to receive the clock signal.
If the signal is weak, it could take up to 24 hours to
receive a valid signal.
To enable/disable signal reception:
Press and hold RCC.
SET THE CLOCK MANUALLY
1. Press and hold RCC in the battery compartment to
disable the clock signal reception.
2. Press and hold .
3. Press +/- to change the settings.
4. Press to conrm.
5. Press once or press and hold +/- to adjust the setting.
For EU/UK, the time-zone offset sets the clock up to
+/- 23 hours from the received clock signal time. For
US, the time-zone setting is 0 (P), 1 (M), 2 (C), 3 (E).
6. Press to conrm.
7. The settings order is: 12/24 hour format, hour, minute,
year, calendar format (day-month/month-day), month,
day and language.
8. Press once or press and hold +/- to adjust the setting.
NOTE The language options are English (E), Spanish (S),
Italian (I), German (D) and French (F).
WEATHER FORECAST
This product forecasts the next 12 hours of weather
within a 19-31 mile (30-50 km) radius.
Screen display Description
Sunny
Cloudy
Rainy
Snowy
TEMPERATURE
To select temperature unit:
• Slide to °C or °F for temperature readings in the
battery compartment of the main unit.
JW108_M_EN.indd 6 14-7-10 1:27

EN
7
PRECAUTIONS
• Do not subject the unit to excessive force, shock,
dust, temperature or humidity.
• Do not cover the ventilation holes with any items
such as newspapers, curtains etc.
• Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
• Do not clean the unit with abrasive or
corrosive materials.
• Do not tamper with the unit’s internal components.
This invalidates the warranty.
• Only use fresh batteries. Do not mix new and
old batteries.
• Images shown in this manual may differ from the
actual display.
• When disposing of this product, ensure it is
collected separately for special treatment and not
as household waste.
• Placement of this product on certain types of
wood may result in damage to its nish for which
Oregon Scientic will not be responsible. Consult
the furniture manufacturer's care instructions
for information.
• The contents of this manual may not be reproduced
without the permission of the manufacturer.
• Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for
special treatment is necessary.
• Please note that some units are equipped with
a battery safety strip. Remove the strip from the
battery compartment before rst use.
NOTE The technical specications for this product and
the contents of the user manual are subject to change
without notice.
NOTE Features and accessories will not be available
in all countries. For more information, please contact
your local retailer.
SPECIFICATIONS
TYPE DESCRIPTION
MAIN UNIT
L x W x H 390 x 243 x 25 mm
15.3 x 9.57 x 0.98 in
Weight 1052 g (37.1 ounces)
without battery
Operation range -5°C to 50°C
(23°F to 122°F)
Time format 24/12 Hour with
AM/PM
Temperature format °C/°F
Date format MM:DD/DD:MM
JW108_M_EN.indd 7 14-7-10 1:27

EN
8
Day-of-week display English/French/
German/Spanish/
Italian
Power 3 x UM-3 (AA) 1.5 V
batteries
REMOTE UNIT
L x W x H 94.5 x 48 x 27 mm
(3.72 x 1.89 x 1.06 in)
Weight 44 g (1.55 ounces)
without battery
Transmission range 98 ft (30 m)
unobstructed
Temperature range -20°C to 60°C
(-4°F to 140°F)
Power 2 x UM-3 (AA) 1.5 V
batteries
Splash-proof standard JIS-3
ABOUT OREGON SCIENTIFIC
Visit our website www.oregonscientic.com to learn
more about Oregon Scientic products.
For any enquiry, please contact our Customer Service
at info@oregonscientic.com.
Oregon Scientic Global Distribution Limited reserves
the right to interpret and construe any contents, terms
and provisions in this user manual and to amend it, at
its sole discretion, at any time without prior notice. To
the extent that there is any inconsistency between the
English version and any other language versions, the
English version shall prevail.
EU - DECLARATION OF CONFORMITY
Hereby, Oregon Scientic, declares that Jumbo Wall
Clock (Model: JW108) is in compliance with the essential
requirements and other relevant provisions of Directive
1999/5/EC. A copy of the signed and dated Declaration
of Conformity is available on request via our Oregon
Scientic Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries, Switzerland
and Norway N
CH
JW108_M_EN.indd 8 14-7-10 1:27

EN
9
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
WARNING Changes or modications not expressly
approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician
for help.
JW108_M_EN.indd 9 14-7-10 1:27

EN
10
DECLARATION OF CONFORMITY
The following information is not to be used as contact for
support or sales. Please call our customer service number
(listed on our website at www.oregonscientic.com), or on
the warranty card for this product) for all inquiries instead.
We
Name: Oregon Scientic, Inc.
Address: 10778 SW Manhasset Dr.
UNIT B-2 Tualatin,
Or 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: JW108
Product Name: Jumbo Wall Clock
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: 1) This device
may not cause harmful interference. 2) This device must
accept any interference received, including interference
that may cause undesired operation.
JW108_M_EN.indd 10 14-7-10 1:27

EN
11
© 2014 Oregon Scientic. All rights reserved.
300103701-00001-10
JW108_M_EN.indd 11 14-7-10 1:27