Orpak Systems 813207300 DATAPASS User Manual 1
Orpak Systems Ltd. DATAPASS 1
User Manual
DataPass & µDataPass P/N 817407400 Rev A2 1. SCOPE This document provides a general and functional description of the DataPass and µDataPass units. 2. DATAPASS & µDATAPASS DESCRIPTION DataPass and µDataPass are miniature units that connect to the vehicle bus and capture data from the vehicle CPU/BUS. They then transmit this data to the nearest Wireless Gateway in the forecourt. Two unit types are available for the installer (see Figure 1 and Figure 2): µDataPass (CAN) for CAN Bus Protocol µDataPass (k-line) for K-line Protocol Figure 1. µDataPass DataPass for Light Vehicles (OBD-II) DataPass AVL for Heavy Vehicles Figure 2. DataPass FCC Compliance Statement for DataPass/µDataPass µDataPass – a connector shaped unit that plugs into the vehicle On Board Diagnostics connector (OBD II) and intended for light and commercial vehicles which has OBD II connector. The following µDataPass types are available: µDataPass CAN, P/N 800907435 µDataPass K-Line, P/N 800907436 µDataPass Plus CAN, P/N 800907430 µDataPass Plus K-Line, P/N 800907431 DataPass - connected directly to the vehicle bus harness, used in heavy and light vehicles and supports most common bus protocols. The following DataPass types are available: DataPass Heavy, P/N 800907340 DataPass Light, P/N 800907330 DataPass Plus Heavy, P/N 800907310 DataPass Plus Light, P/N 800907300 DataPass AVL Heavy, P/N 800907540 DataPass AVL Light, P/N 800907541 NOTE Please check the manufacturer specifications for the proper protocol supported by the Vehicles in your fleet! The DataPass is installed using the provided DataPass harness. The harness is installed inside the driver cabin, behind the dashboard and connects to the vehicle's diagnostics connector in light vehicles, or to the diagnostics plug rear wiring in heavy vehicles. 3. DATAPASS – TECHNICAL SPECIFICATION Table 1 lists the specifications for the DataPass units. Table 1. DataPass Specifications Parameter Physical Electrical Value HxWxD 15x70x21 mm Weight 45g Connectors 562810 Molex Supply voltage Normal operation: 12VDC (Nominal) Minimum: 10 VDC FCC Compliance Statement for DataPass/µDataPass Parameter Value Maximum: 32 VDC Current consumption (typical) KLINE Mode: Sleep mode: 5mA Active mode: 35mA CAN Mode: Sleep mode: 5mA Active mode: 25mA J1708 Mode: Sleep mode: 5mA Active mode: 25mA Temperature Range Environmental Conditions Operating: -40 to +70 ºC Storage: -40 to +85 ºC Humidity 95% non-condensing Wireless Interfaces Single IEEE802.15.4 wireless channel Operating Frequency: ISM 2.405 to 2.480 GHz (Global license free band) Implements proprietary mesh network IEEE802.15.4 Modem DSSS/FA – Direct Sequence Spread Spectrum with Frequency Agility Supported network topologies: Propriety mesh network Channel capacity: 16 frequency channels / 5MHz channel spacing Communication Transmit power output: 2mW (3dbm) Receive sensitivity: -101dbm Wireless Antenna Built in PCB Antenna Wired Interfaces OBDII – J2284/ISO15765 (CAN BUS) Data rate: 250Kbps / 500Kbps OBDII – ISO14230/ISO9141 (KLINE) Data rate: 10400bps J1708/J1587 Data rate: 9600bps Table 2 lists the specifications for the μDataPass units. FCC Compliance Statement for DataPass/µDataPass Table 2.μDataPass Specifications Parameter Physical Value HxWxD 22x70x17 mm Weight 10g Connectors OBDII compatible (male) Supply voltage Normal operation: 12VDC (Nominal) Minimum: 10 VDC Maximum: 32 VDC Electrical Current consumption (typical) KLINE Interface: Sleep mode: 4mA Active mode: 35mA CAN Interface: Sleep mode: 4mA Active mode: 25mA Environmental Conditions Temperature Range Operating: -40 to +70 ºC Storage: -40 to +85 ºC Wireless Interfaces Single IEEE802.15.4 wireless channel Operating Frequency: ISM 2.405 to 2.480 GHz (Global license free band) Implements proprietary Mesh network IEEE802.15.4 Modem DSSS/FA – Direct Sequence Spread Spectrum with Frequency Agility Supported network topologies: Propriety Mesh network Channel capacity: 16 frequency channels / 5MHz channel spacing Communication Transmit power output: 2mW (3dbm) Receive sensitivity: -101dbm Wireless Antenna Built in PCB Antenna Wired Interfaces OBDII – J2284/ISO15765 (CAN BUS) Data rate: 250Kbps / 500Kbps OBDII – ISO14230/ISO9141 (KLINE) Data rate: 10400bps FCC Compliance Statement for DataPass/µDataPass FCC COMPLIANCE STATEMENT IN USER'S MANUAL This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For a Class A or Class B digital device or peripheral, the instructions GIVEN to the user shall include the following, or a similar statement should be placed in a prominent location in the text of the manual (Section 15.105). The User’s Manual or Instruction Manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. (from FCC rules 15.21): Sample user information for a Class A digital device: THE FCC WANTS YOU TO KNOW: This equipment has been tested and found to comply with the limits or a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. his equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, ay cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Warning Modifications not expressly approved by the manufacturer responsible could void the user’s authority to operate the equipment under FCC rules. FCC Compliance Statement for DataPass/µDataPass Sample user information for a Class B digital device THE FCC WANTS YOU TO KNOW: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential area. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. however, there is no guarantee that interference will not occur in a particular installation. if this equipment does not cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician FCC Warning Modifications not expressly approved by the manufacturer responsible could void the user’s authority to operate the equipment under FCC rules. FCC Compliance Statement for DataPass/µDataPass
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : yoram_f Create Date : 2012:10:03 13:56:19+02:00 Modify Date : 2012:10:03 16:37:15+02:00 Language : he-IL Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : yoram_f Title : 1 Creator Tool : Microsoft® Word 2010 Metadata Date : 2012:10:03 16:37:15+02:00 Producer : Microsoft® Word 2010 Document ID : uuid:3e55f291-d1dc-4689-af34-a66db1e703ce Instance ID : uuid:17e8b6ac-c203-4005-8ab5-013a932c6a07 Page Count : 6EXIF Metadata provided by EXIF.tools