OTT 0051B English Operating Instructions Radar Sensor Kalesto Connection diagram Voltage supply A separate voltage supply is required for the radar sensor if cables exceed a certain length; see Technical Data (use commercially-available distributor socket) Twisted pair cable up to max. 1,000 m OTT-LOG connection diagram Kalesto input card 1 2 3 4 5 6 ±5˚ RS 485 A RS 485 B n.c. n.c. n.c. n.c. Distance between radar/ sensor water surface Safety distance between buildings and centre axis 5m 10 m 20 m 30 m 0.5 m 1m 2m 3m Adjust the positioning mechanism so that the radar sensor is aligned at right angles to the water surface. (Check with a spirit-level.) Opening the connection section on the Kalesto radar sensor (captive screws). Connecting the twisted pair cable to the radar sensor. RS 485 A RS 485 B Ground +12 V DC Setting the OTT-LOG operating matrix for a Kalesto radar sensor Field 15 Enter scaling + point position; create relation to reference point 15± SCALING 100% 0.00 0% 30.00 POINT POS xxx.xx 100% + 0% = Adjusts the OTT-LOG to the Kalesto radar sensor measurement range. POINT POS = Sets the decimal point position within the measured value The Kalesto radar sensor measures the distance from the bottom of its housing* to the water surface: the maximum measured value is 30.00 m. The measurement result for distance or level measurement is scaled by entering a value in the 0 % and 100 % boxes in field 15 of the OTT-LOG operating matrix. * Please note that the measurement zero point is initially positioned some centimetres inside the sensor housing. After scaling with relation to a reference point, you can check the result of all subsequent measurements (housing bottom/water surface) using an electric contact gauge, for example. Scaling for water level measurements (with relation to reference point) Carry out measurement using the settings 100 % = 0.00; 0 % = 30.00 (result in matrix field 10). Determine the reference value using a staff gauge, for example. Calculate: Correction value = Displayed value – staff gauge value Enter scaling/comma position → New 100 % value = 0.00 – correction value → New 0 % value = 30.00 – correction value Important: Do not forget the sign! Example: Display in field 10 Staff gauge reference value Correction value → New 100 % value → New 0 % value 18.50 1.15 17.35 –17.35 12.65 Scaling for distance measurements (depth of water) (radar sensor ↔ water surface with relation to a reference point) Perform measurement using the settings 100 % = 30.00; 0 % = 0.00 (result in matrix field 10). Determine the reference value using an electric contact gauge, for example. Calculate: Correction value = Displayed value – electric contact gauge value Enter scaling/comma position → New 100 % value = 30.00 – correction value → New 0 % value = 0.00 – correction value Important: Do not forget the sign! Enter scaling/decimal point position: † ™® Select digit position; ∑« Select sign/digits † ™® Select digit position; ∑« Select sign/digits † ∑« Select decimal point position Factory setting: 100% = 0.00; 0% = 30.00; POINT POS = xxx.xx – Possible decimal point positions: xxx.xx → Resolution 1 cm xx.xxx → Resolution 1 mm * xxx.xx → Resolution 0.01ft – Do not forget the sign in all entries! – The decimal point position also affects the matrix fields 10, 11, 14, 15, 16 and 18. – For a resolution in 0.01 ft: Use 98.43 instead of 30.00 (30 m = 98.43 ft) * For distance measurements: possible using OTT-LOG version V2.16 and later versions (100 % value, 0 % value: max. ±29.999 m) Operating mode „surface velocity“ This operating mode of the Kalesto is provided for the approach determination of the surface velocity of a river. Please note: The accuracy of measured values depends on the roughness of water surface. Strong wind influences or very smooth water surfaces falsify measuring results. Special input card for OTT-LOG necessary: 55.505.138.3.2 Min. surface velocity vmin = 1 m/s The actual velocity of the river is larger than the measured velocity of the KALESTO: v = v Kalesto/ cos a For this reason it is necessary to enter a correction value in the 100 % field of the matrix. Through this the OTT-LOG calculates the resulting velocity automatically. Scaling for surface velocity Determine the value for 100 % from the table. Enter 100 % and 0 % value; e. g. α = 45 ° → 100 % value = 42.43 → 0 % value = 0.00 The OTT-LOG displays the measured value in m/s. Radar Sensor Kalesto: Operating mode „surface velocity“ α Flow direction Angle 30 35 40 45 50 55 60 ° ° ° ° ° ° ° 100 % value hmin hmax (field 10) approx. approx. 34.64 36.62 39.16 42.43 46.67 52.30 60.00 1.00 1.10 1.25 1.40 1.50 1.60 1.70 10.5 12.0 13.5 15.0 16.0 17.0 18.0 (Point position: xxx.xx) Technical data Measurement range Resolution Maximum measurement error1) 1.5 … 30 m 1 mm ±1 cm + 1 digit Operating voltage Current consumption – Active – Standby mode 9 … 15 V DC 550 mA < 1µA Interface Transmission speed RS 485; max. 1,000 m twisted pair cable 9,600 bit/s Microwave frequency Transmission output Radiation angle 24.125 GHz 5 mW ±5° Length of measurement cycle Measured value output 17 s 17 s after measured value request When the device is combined with an OTT-LOG data logger in the HYDROSENS “MIDI” housing, operation and measured value readings are performed using the OTT-LOG operating matrix. Degree of protection Insertable cable Filling Authorisation number Dimensions L x Diam. Weight Temperature range IP 68 e. g. Li2YCYv (TP) 2 x 2 x 0.5 mm2 Nitrogen; 0.5 bar overpressure D810117L approx. 500 mm x 160 mm approx. 8.0 kg –40 to +85 °C 1) under reference conditions A separate voltage supply is required for the Kalesto radar sensor if cables exceed a certain length (voltage reduction in twisted pair cable): Wire cross-section in mm2 0.5 1.0 1.5 Max. cable length for voltage supply 12 V 15 V 35 m 70 m 110 m 100 m 200 m 300 m OTT MESSTECHNIK GmbH & Co. KG P.O. Box 21 40 ⋅ D-87411 Kempten Ludwigstrasse 16 ⋅ D-87437 Kempten Phone ++49(0)8 31 56 17-0 Fax ++49(0)8 31 56 17-2 09 Document number 63.100.000.B.E 06-1100 E-mail: info@ott-hydrometry.de Internet: http://www.ott-hydrometry.de
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 2000:11:07 13:12:10 Producer : Acrobat Distiller 4.0.2 for Macintosh Author : Armin Vogelmann Creator : QuarkXPressª: AdobePS 8.6 (219) Title : Anleitung RADAR D.ENG Modify Date : 2000:11:07 13:16:09+01:00 Page Count : 8 Page Mode : UseThumbsEXIF Metadata provided by EXIF.tools