In-Touch Loyalty Marketing System
Dispenser TouchPoint Unit Installation Manual
Includes important information for the installation of TouchPoint units.
Version 3.1 November 2006
Model FMPWR-2
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
Copyright © 2006 Outsite Networks, Inc.™ All rights reserved. Outsite Networks, Inc. created this document. No
part of this publication may be reproduced, stored in a retrieval system, modified, or transmitted in any form or by
any means (electronic, mechanical, photocopying, recording or otherwise) without the express, prior written
consent of the Outsite Networks, Inc.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Outsite Networks, Inc.
4855 Brookside Court
Norfolk, VA 23502
Office: (757) 853-3000
Fax: (757) 853-3089
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
Dispenser TouchPoint Unit Installation Manual
Contents
10
11
12
13
Section
Page
Electrical Connection Specifications
Physical and Power Specifications
Site Preparation
Secure Working Area
Turn Dispenser A\C Power Off
Prepare to Mount the Dispenser TouchPoint Unit
Connect Power
Connect the TouchPoint to the Dispenser
Enter Programming Mode
Program the Volume Level
Program the Fueling Position
Test the Dispenser TouchPoint Units
Post Installation
Limited Warranty
Gasoline Dispensing and Service Stations Diagram
Dispenser TouchPoint Unit Drilling Template
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
1. Electrical Connection Specifications
1.1
Read this guide completely prior to installing the Dispenser TouchPoint Unit.
1.2
All electrical connections must comply with the following:
Equipment must be installed and used in accordance with the National Electric Code (NEC), and
the National Fire Protection Association (NFPA) – Automotive and Marine Service Station Code.
1.3
Equipment must be installed in compliance with instructions set forth in this manual.
1.4
This manual contains wiring diagrams, drawings, and photographs to assist in the proper
installation of the In-Touch System equipment. Any questions regarding this manual or the proper
installation of the TouchPoint Unit should be addressed to the Service department of Outsite
Networks, Inc. at 800-371-1118.
2. Physical and Power Specifications
2.1 Dispenser TouchPoint AC to DC Power Supply
2.1.1
Physical Dimensions:
Height
Width
Length
Weight
2. 1.2
Power Requirements:
Single Phase
2.1.3
1 ½”
2”
4 ½”
2 lbs.
120VAC / 50-60Hz
.6 Amps @ 120VAC
.125 Amps (typical value)
Operating Environment:
Rain Proof Enclosure
Minimum Temperature -20°C ambient
Maximum Temperature +40°C ambient
2.2 Dispenser TouchPoint Physical and Power Specifications
2.2.1
Physical Dimensions:
Height
Width
Length
Weight
2.2.2
5 ¼”
4”
2”
1 lbs.
Power Requirements:
12VDC
.5 Amps @ 12VDC
.25 Amps (typical value)
2.2.3
Operating Environment:
Rain Proof Enclosure
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 1 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
Minimum Temperature -20°C ambient
Maximum Temperature +40°C ambient
3. Site Preparation
3.1
Installation must comply with the National Electric Code, the National Fire Protection Association
codes and all applicable state and local codes.
3.2
Follow all safety precautions appropriate to working at locations where flammable liquids are
stored; refer to Appendix A.
3.3
The site must be equipped with electrical service to meet the requirements of the installation
instructions.
3.4
Supplied Materials
•
•
•
•
•
•
3.5
TouchPoint Unit
TouchPoint AC to DC Power Supply
AC Adaptor Cable
10-32 Bolts (for mounting)
Lock Nuts
Template
List of recommended tools
•
•
•
•
•
Tape measure
¼” drill bit
½” drill bit
Manual hand or low speed pneumatic drill
9” Lineman’s pliers or slip joint pliers
3.6
The TouchPoint unit can be mounted in several positions on the front panel of the dispenser’s
electronic cabinet head.
3.7
Before mounting, ensure that there are no electronic components on the interior of the electronic
cabinet door where the unit is being mounted and that mounting the TouchPoint unit does not
obstruct future maintenance of the fuel dispenser. Mount the unit above the dispenser’s vapor
barrier.
3.8
The TouchPoint power supply is connected to the dispenser AC power. The TouchPoint power
supply converts AC power to DC power.
4. Secure Working Area
4.1
Before working on the dispenser, block customer access to the dispenser island with traffic safety
cones or other appropriate barriers.
4.2
Do not allow vehicles, customers or other unauthorized people in the barricaded area.
4.3
Do not smoke, or allow other open flames or arcing and sparking devices in the barricaded area.
4.4
NOTE: Important Safety Information - Check the work area around the dispenser to ensure that
an explosive mixture of vapors is not present.
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 2 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
Illustration A: Barricaded dispenser island
5. Turn Dispenser A/C Power Off
5.1
Before working on the dispenser, use the circuit breaker in the electrical service box to turn off the
A/C power supply to the dispenser.
6. Prepare to Mount the Dispenser TouchPoint Unit
6.1
Place the template of the TouchPoint unit (provided at the end of this manual) at the desired
location of the fuel dispenser. The selected location should be consistent on both sides of the
dispenser and should be installed in the same position on each dispenser of the same type at the
location. (See Illustration B)
Illustration B: Find a desired location for the
TouchPoint unit.
6.2
Remove all stickers and decals from the front panel where the unit will be installed. Replace the
decals as necessary in alternate locations.
NOTE: (concerning dispenser stickers) When relocating stickers, ensure that the chosen alternate location
is equally visible. If necessary, replace with a smaller sticker.
6.3
Using the template, mark the location of the two ¼” and middle ½” holes on the fuel dispenser.
6.4
Drill the two ¼” holes using a manual hand, or low speed pneumatic drill using a ¼” drill bit.
6.5
Drill the middle ½” hole using a manual hand, or low speed pneumatic drill using a ½” drill bit.
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 3 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
6.6
Repeat section 8.1 through 8.5 for the “B” side of the dispenser.
NOTE: Important Safety Information – Use extreme caution not to puncture or damage any electronics or
other components in the dispenser’s electronic cabinet.
NOTE: Important Safety Information – Check the work area around the dispenser to ensure that an
explosive mixture of vapors is not present.
7. Connect Power
7.1
The TouchPoint AC Power Supply, Illustration D, supplies DC voltage for up to two TouchPoint
devices mounted on one dispenser. ONI supplies specific AC Adaptor cables per each dispenser
manufacturer.
7.2
Connect the manufacturer appropriate AC Adaptor cable to the TouchPoint AC Power Supply.
7.3
Once connected to the power supply, connect the AC Adaptor cable to an available position on the
dispenser’s AC buss.
Illustration C: Gilbarco AC Adaptor Cable.
Illustration C.1: Sample Gilbarco dispenser AC buss.
Illustration D: Dresser Wayne AC Adaptor
Cable.
Illustration D.1: Sample Dresser Wayne dispenser AC
buss.
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 4 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
Illustration E: Outsite Networks supplied Touch
Point AC Power Supply.
8. Connect the TouchPoint to the Dispenser
8.1
Thread the TouchPoint connector cable through the ½” middle hole.
8.2
Place the TouchPoint unit on the dispenser at the designated install location.
8.3
Secure the TouchPoint unit to the dispenser using a washer, a lock washer, and a 7/8” screw for
each ¼” hole (in that order).
NOTE: When fastening the TouchPoint unit to the dispenser, ensure the connection is tight and that the
rubber gasket is making contact with the dispenser all the way around the unit. This will prevent moisture
from entering the dispenser through the 3 holes behind the TouchPoint.
8.4
Repeat steps 8.1 through 8.3 for the opposite side of the dispenser.
8.5
Connect the opposite ends of the TouchPoint AC Power Supply cables to the TouchPoint connector
cables on sides A and B of the dispenser.
**Suggested step: Using a small wire tie, bind the TouchPoint unit
connector cable with the Touch Point AC Power Supply cable beneath
their connection to ensure they will not become disconnected during
future service or maintenance inside the dispenser.
8.6
Route the Touch Point AC Power Supply cables in a manner to ensure adequate cable length to
allow door panels to open as necessary.
9. Enter Programming Mode
9.1
Use the circuit breaker to turn on power to the fuel dispenser. When the TouchPoint unit is
powered up, it will speak the unit mode, the unit group (Network ID), and the unit ID (unit number).
9.2
If the units are online (meaning that the In-Touch System Server and repeater are installed and
on), pressing any of the keys will produce an audible beep.
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 5 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
9.3
To place the TouchPoint unit in the programming mode simultaneously press and hold the YES
and NO buttons.
9.4
After about two seconds, the TouchPoint unit will prompt for changes. This indicates that the units
are in programming mode.
9.5
To choose a setting to change, press the YES button when prompted.
9.6
To skip to the next setting, press the SELECT button until the desired option is heard.
9.7
To exit programming mode, press NO.
10. Program the Volume
10.1
The volume of the TouchPoint should be programmed immediately after installation. To program
the Volume Level, press the YES and NO buttons simultaneously to enter programming mode. A
prompt saying the TouchPoint unit information should be heard.
10.2
The unit will prompt, “Press YES for Volume Level. Press SELECT for more options.”
10.3
Press YES to confirm the selection of “Volume Level.”
10.4
The unit will prompt, “Press YES to cycle Volume Level. Press SELECT for more options.”
10.5
Press YES to cycle the Volume Level.
10.6
The unit will state the Volume Level that is currently programmed. To change the Volume Level;
increase by pressing the YES button. (There is no option to decrease the volume level, but the
unit will automatically cycle around at 20 and go back to 1.)
10.7
When finished programming, press the NO key to exit.
11. Program the Fueling Position
11.1
11.2
The fueling position of the TouchPoint unit should be programmed immediately after installation.
To program the fueling position, press the YES and NO buttons simultaneously to enter
programming mode. A prompt saying the TouchPoint unit information should be heard.
The unit will prompt, “Press YES for Volume Level. Press SELECT for more options.”
11.3
Press SELECT on the TouchPoint until “Unit Number” is heard.
11.4
Press YES to confirm the selection of Unit Number.
11.5
The unit will prompt, “Press YES to cycle Unit Number. Press SELECT for more options.”
11.6
Press YES to cycle the unit number.
11.7
The unit will state the Unit Number that is currently programmed. To change the current Unit
Number, increase by pressing the YES button. (There is no option to decrease the number, but the
unit will automatically cycle around at 32 and go back to 1.)
11.8
When finished programming, press the NO key to exit.
NOTE: It is necessary to individually program both the A and B side TouchPoint units to correspond ot the
fueling position at which the unit is installed.
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 6 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
NOTE: It is NOT necessary to program the mode of the TouchPoint units. This is factory preset at 1 and
should remain the same.
NOTE: IF two or more locations are within a half mile proximity to one another, the Network ID’s should be
programmed. In such situations, please contact Outsite Networks, Inc. Service Group at 800-371-1118.
12. Test the Dispenser TouchPoint Units
12.1
If the In-Touch System Server is installed, swiping a tag should indicate a response from the
Dispenser TouchPoint unit.
12.2
If the help message plays on a different TouchPoint unit, either the unit where the HELP button
was pressed, or the unit where the message incorrectly played, it is programmed incorrectly.
12.3
If the help message plays properly, place a loyalty tag near the TouchPoint unit. If online, the unit
should beep and then play an audio welcoming message.
12.4
After all of the TouchPoint units are installed and the In-Touch System Server is installed and
connected to the Internet, each TouchPoint unit should be tested again.
13. Post Installation
13.1
Packaging and installation materials should be removed from the dispenser island and properly
disposed.
13.2
Remove the safety traffic cones used to barricade the dispenser island.
13.3
If necessary, the TouchPoint units should be cleaned using a damp warm cloth to remove
smudges and other marks. Soapy water or a non-abrasive cleaning solution may be used.
The site operator should be instructed in the proper cleaning procedures
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 7 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
Limited Warranty
Outsite Networks™, Inc. (ONI) warrants for one year from the date of shipment those new products manufactured
by the company and for six months those products remanufactured by the company, when installed in accordance
with Outsite Networks' specifications, against defective material or workmanship, but not against damage caused
by accident, abuse, faulty installation, third-party modifications or improper operation. This limited warranty is
extended only to the first end-user, regardless of whether that end-user obtained the equipment from Outsite
Networks, Inc., its distributor, or otherwise.
During the warranty period, Outsite Networks, Inc. will, at its option, replace a defective product with a new or
remanufactured product. Outsite Networks will ship the replacement product at no charge to the customer. The
customer will be responsible for the shipping charges to return the defective product. The customer will be
invoiced for any defective product not returned to Outsite Networks within 30 days of the replacement's shipment
date.
Any Outsite Networks, Inc. product purchased from Outsite Networks, Inc. or its Sales Representative or
Distributor, are subject to the following disclaimers and limitations of liability set forth hereinafter. Outsite
Networks, Inc. warrants only those products manufactured by Outsite Networks, Inc. Products sold by
Outsite Networks, Inc., but not manufactured by Outsite Networks, Inc., are covered by the manufacturer's
warranty only.
Any changes in design or improvements added shall not create any obligation to install same on
equipment previously sold.
Outsite Networks, Inc. liability is that exclusively stated herein, and Outsite Networks, Inc. shall not be
liable for any special, indirect, incidental, or consequential damages of any type, including, but not limited
to, damages, loss of product, loss of profit or sales, or any other expense resulting from the nonconforming or defective condition of any products or of any system purchased by the end-user.
To the extent permitted by law, this warranty is given in lieu of all other warranties, expressed or implied, including
the implied warranties of merchantability and fitness for a particular purpose, and Outsite Networks, Inc. neither
assumes, nor authorizes any person to assume for it, any liability beyond that stated herein.
The end-user expressly accepts by use of Outsite Networks, Inc.'s product, equipment, or systems, all liability for all
consequences arising out of the use of such product, equipment, or system. The limited warranty stated herein is
the exclusive remedy of the end-user; and this limitation of liability provision shall apply to any and all claims or
lawsuits based on negligence, breach of contract, breach of warranty, strict liability, or any other legal theory upon
which liability may be asserted against Outsite Networks, Inc. by the end-user of Outsite Networks, Inc.'s products
or systems.
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 8 of 9
Outsite Networks, Inc.
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
National Electrical Code
GASOLINE DISPENSING AND SERVICE STATIONS – ARTICLE 514
Table 514-2. Class I Locations -- Service Stations
Location
Class I,
Group D, Division
Extent of Classified Location
Outsite Networks, Inc. 4855 Brookside Court Norfolk, VA 23502 Office: (757) 853-3000 Fax: (757) 853-3089
Page 9 of 9
Outsite Networks, Inc.
In-Touch Loyalty Marketing System
Dispenser TouchPoint Unit Installation Manual
Version 3.1 November 2006
Model FMPWR-2
Dispenser TouchPoint Unit Template.
Cut out template from this page to plan install location of
Dispenser TouchPoint Unit.
Top and Bottom holes are 1/4”.
Middle hole is 1/2”

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 13
Profile CMM Type                : Lino
Profile Version                 : 2.1.0
Profile Class                   : Display Device Profile
Color Space Data                : RGB
Profile Connection Space        : XYZ
Profile Date Time               : 1998:02:09 06:49:00
Profile File Signature          : acsp
Primary Platform                : Microsoft Corporation
CMM Flags                       : Not Embedded, Independent
Device Manufacturer             : IEC
Device Model                    : sRGB
Device Attributes               : Reflective, Glossy, Positive, Color
Rendering Intent                : Perceptual
Connection Space Illuminant     : 0.9642 1 0.82491
Profile Creator                 : HP
Profile ID                      : 0
Profile Copyright               : Copyright (c) 1998 Hewlett-Packard Company
Profile Description             : sRGB IEC61966-2.1
Media White Point               : 0.95045 1 1.08905
Media Black Point               : 0 0 0
Red Matrix Column               : 0.43607 0.22249 0.01392
Green Matrix Column             : 0.38515 0.71687 0.09708
Blue Matrix Column              : 0.14307 0.06061 0.7141
Device Mfg Desc                 : IEC http://www.iec.ch
Device Model Desc               : IEC 61966-2.1 Default RGB colour space - sRGB
Viewing Cond Desc               : Reference Viewing Condition in IEC61966-2.1
Viewing Cond Illuminant         : 19.6445 20.3718 16.8089
Viewing Cond Surround           : 3.92889 4.07439 3.36179
Viewing Cond Illuminant Type    : D50
Luminance                       : 76.03647 80 87.12462
Measurement Observer            : CIE 1931
Measurement Backing             : 0 0 0
Measurement Geometry            : Unknown
Measurement Flare               : 0.999%
Measurement Illuminant          : D65
Technology                      : Cathode Ray Tube Display
Red Tone Reproduction Curve     : (Binary data 2060 bytes, use -b option to extract)
Green Tone Reproduction Curve   : (Binary data 2060 bytes, use -b option to extract)
Blue Tone Reproduction Curve    : (Binary data 2060 bytes, use -b option to extract)
Application Record Version      : 2
IPTC Digest                     : 460cf28926b856dab09c01a1b0a79077
X Resolution                    : 300
Displayed Units X               : inches
Y Resolution                    : 300
Displayed Units Y               : inches
Print Style                     : Centered
Print Position                  : 0 0
Print Scale                     : 1
Global Angle                    : 30
Global Altitude                 : 30
Copyright Flag                  : False
URL List                        : 
Slices Group Name               : fulltemplate
Num Slices                      : 1
Pixel Aspect Ratio              : 1
Photoshop Thumbnail             : (Binary data 2635 bytes, use -b option to extract)
Has Real Merged Data            : Yes
Writer Name                     : Adobe Photoshop
Reader Name                     : Adobe Photoshop CS
Exif Byte Order                 : Big-endian (Motorola, MM)
Orientation                     : Horizontal (normal)
Resolution Unit                 : inches
Software                        : Adobe Photoshop CS Windows
Modify Date                     : 2006:12:12 16:20:19
Color Space                     : sRGB
Exif Image Width                : 2550
Exif Image Height               : 3450
Compression                     : JPEG (old-style)
Thumbnail Offset                : 302
Thumbnail Length                : 0
Create Date                     : 2007:02:28 09:43:45-05:00
Producer                        : iText by lowagie.com (r1.02b;p128)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U2C-FMPWR-2-3

Navigation menu