Overland Storage Reo 9000 Users Manual Setup Guide
REO 9000 to the manual 893bb103-906e-4cf7-a7c8-38542d8659cc
2015-02-05
: Overland-Storage Overland-Storage-Reo-9000-Users-Manual-498143 overland-storage-reo-9000-users-manual-498143 overland-storage pdf
Open the PDF directly: View PDF .
Page Count: 170
Download | ![]() |
Open PDF In Browser | View PDF |
Overland Storage REO 9000 with ProtectionPAC Software Disk-Based Backup-andRecovery Appliance Setup Guide OVERLAND STORAGE END USER LICENSE AGREEMENT (“EULA”) IMPORTANT NOTICE - PLEASE READ THIS END USER SOFTWARE LICENSE AGREEMENT (“EULA”) CAREFULLY BEFORE USING THE SOFTWARE CONTAINED IN THIS EQUIPMENT OR USING THIS EQUIPMENT IN ANY MANNER. BY USING THE EQUIPMENT THAT CONTAINS THIS SOFTWARE, YOU ARE CONSENTING TO BE BOUND BY THIS AGREEMENT. IF YOU DO NOT AGREE TO ALL OF THE TERMS OF THIS END USER AGREEMENT, PROMPTLY RETURN AND DO NOT USE THE EQUIPMENT AND THE SOFTWARE. 1. Single User License. Subject to the terms and conditions of this EULA, Overland Storage, Inc. (“Overland”) grants to you (“Customer”) a non-exclusive, non-transferable license to use (a) Overland software which provides the basic operating environment for Overland equipment and whether pre-installed on, embedded in or provided with Overland equipment, and (b) the specific Overland program modules or features which have been enabled by security keys supplied by Overland and for which Customer had paid any applicable license fees (collectively, the “Software”), both of the foregoing in object code form only: (i) solely as pre-installed, embedded in or provided with Overland equipment owned or leased by Customer; and (ii) for key-enabled Software corresponding to the security key(s) supplied by Overland and for the license fees paid by Customer. 2. Limitations. Except as otherwise expressly provided under this EULA, Customer will have no right, and Customer will not: (i) make error corrections to or otherwise modify or adapt the Software nor create derivative works based upon the Software, or to permit third parties to do the same; (ii) copy, in whole or in part, de compile, translate, reverse engineer, disassemble or otherwise reduce the Software to humanreadable form; or (iii) remove the Software from the equipment in which it is embedded. 3. Upgrades and Additional Copies. For purposes of this EULA, “Software” will also include (and the terms and conditions of this EULA will apply to) any upgrades, updates, bug fixes or modified versions (collectively, “Upgrades”) or backup copies of the Software licensed or provided to Customer by Overland or an authorized distributor for which Customer had paid the applicable license fees and holds the corresponding software keys. Notwithstanding the foregoing, Overland will have no obligation to provide any Upgrades under this EULA. If Upgrades are provided, (i) Customer has no license or right to use any such additional copies or Upgrades unless Customer, at the time of acquiring such copy or Upgrade, already holds a valid license and the corresponding security keys to the original Software; and (ii) use of the Upgrades is limited to Overland equipment for which Customer is the original End-User purchase or lessee.4. U.S. Government Restriction Rights. The Software was developed at private expense and is provided with “RESTRICTED RIGHTS” as set forth in this License Agreement. Use, duplication or disclosure by the United States government is subject to restrictions as set forth in FAR 52.227-14 and DFARS 252.227-7013 et seq., or its successors. The use of this Software constitutes acknowledgement of Company's and its licensors' rights in the Software. 4. Notices of Proprietary Rights. Customer will maintain and reproduce all trademark, copyright, patent, and notices of other proprietary rights on all copies, in any form, of the Software in the same form and manner that such trademark, copyright, patent, and notices of other rights are included on the Software. Except as expressly authorized in this EULA, Customer will not make any copies or duplicates of any Software without the prior written permission of Overland. 5. Proprietary Rights. The Software is and will remain the sole and exclusive property of Overland. Software is licensed, not sold, by Overland hereunder. Any references to terms in connection with the foregoing, such as “sale”, “purchase” or “sell” will be interpreted as licensed rights granted on a non-exclusive basis hereunder and as otherwise provided in this EULA. Overland's rights under this Section will include, but not be limited to: (i) all copies of the Software, in whole and in part; and (ii) all intellectual property rights in the Software. 6. Confidential Information. Customer will not disclose or, except as expressly permitted in this EULA, use any Software or other technical information disclosed to Customer by Overland (“Confidential Information”). Customer will take all reasonable measures to maintain the confidentiality of all Confidential Information in Customer's possession or control, which will in no event be less than the measures Customer uses to maintain the confidentiality of Customer's own information of equal importance. Confidential Information will not include information that: (i) is in or enters the public domain without breach of this EULA; (ii) Customer receives from a third party without restriction on disclosure and without breach of a nondisclosure obligation; or (iii) Customer develops independently, which Customer can prove with written evidence. The Confidential Information is a trade secret of Overland, the disclosure of which would cause substantial harm to Overland that could not be remedied by the payment of damages alone. Accordingly, Overland will be entitled to preliminary and permanent injunctive relief and other equitable relief for any breach of this Section. 7. Limited Software Warranty. Overland warrants that the Software will substantially conform to its published specifications for a period of 90 days from the later of receipt of the equipment containing the Software or receipt of access to the Software. This limited warranty extends only to Customer as the original licensee. Provided that (a) Customer has notified Overland of such substantial non-conformance during the applicable warranty period, and (b) Overland has confirmed such Software to be substantially nonconforming, as Customer's sole and exclusive remedy and Overland' and its suppliers' entire liability under this limited warranty, Overland will, at its option, repair, replace, or refund the Software pursuant to Overland's then-current warranty policy. Except as expressly provided in this EULA, the Software is provided “AS IS” without warranty of any kind. Overland does not warrant that the Software is error free or that Customer will be able to operate the Software without problems or interruptions. Overland reserves the right to charge additional fees for repairs or replacements performed outside of the 90-day limited warranty period. This warranty does not apply if the Software or the Overland equipment in which the Software is embedded (i) is licensed for beta, evaluation, testing or demonstration purposes for which Overland does not receive a license fee, (ii) has been altered, except by Overland, (iii) has not been installed, operated, repaired, or maintained in accordance with instructions supplied by Overland, (iv) has been subjected to abnormal physical or electrical stress or to misuse, negligence, or accident, or (v) is used in ultra-hazardous activities. 8. Disclaimer. EXCEPT AS SPECIFIED IN THIS EULA, ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS, AND WARRANTIES INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT, SATISFACTORY QUALITY OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE, ARE HEREBY EXCLUDED TO THE EXTENT ALLOWED BY APPLICABLE LAW. IN NO EVENT WILL OVERLAND OR ITS SUPPLIERS BE LIABLE FOR ANY LOST REVENUE, PROFIT, OR DATA, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL, OR PUNITIVE DAMAGES HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF LIABILITY ARISING OUT OF THE USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF OVERLAND OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT WILL OVERLAND'S TOTAL LIABILITY TO CUSTOMER, WHETHER IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR OTHERWISE, EXCEED THE PRICE PAID BY CUSTOMER. THE FOREGOING LIMITATIONS WILL APPLY EVEN IF THE ABOVE-STATED WARRANTY FAILS OF ITS ESSENTIAL PURPOSE. Each party recognizes and agrees that the warranty disclaimers and liability and remedy limitations in this EULA are material bargained for bases of this EULA and that they have been taken into account and reflected in determining the consideration to be given by each party under this EULA and in the decision by each party to enter into this EULA. 9. Term and Termination. This EULA is effective until terminated. Customer's license rights under this EULA will terminate immediately without notice from Overland if Customer fails to comply with any provision of this EULA. Upon termination, Customer must destroy all copies of Software and the corresponding security keys in its possession or control. 10. Compliance With Law. Each party will comply with all applicable laws, rules and regulations in connection with its activities under this EULA. Without limiting the foregoing, the Software, including technical data, is subject to United States export control laws, including the United States Export Administration Act and its associated regulations, and may be subject to export or import regulations in other countries. Customer will comply strictly with all such regulations and acknowledges that Customer has the responsibility to obtain licenses to export, re-export, or import the Software. 11. Restricted Rights. The Software will be classified as “commercial computer software” as defined in the applicable provisions of the Federal Acquisition Regulation (the “FAR”) and supplements thereto, including the Department of Defense (DoD) FAR Supplement (the “DFARS”). The parties acknowledge that the Software was developed entirely at private expense and that no part of the Software was first produced in the performance of a Government contract. If the Software is supplied for use by DoD, the Software is delivered subject to the terms of this EULA and either (i) in accordance with DFARS 227.702-1(a) and 227.7202-3(a), or (ii) with restricted rights in accordance with DFARS 252.227-7013(c)(1)(ii) (OCT 1988), as applicable. If the Software is supplied for use by a Federal agency other than DoD, the Software is restricted computer software delivered subject to the terms of this EULA and (i) FAR 12.212(a); (ii) FAR 52.227-19; or (iii) FAR 52.227-14 (ALT III), as applicable. 12. Third Party Software. Third party suppliers of materials integrated with the Overland equipment disclaim all implied warranties, including the implied warranties of merchantability and fitness for a particular purpose. The collective liabilities of the seller/licensor and its third party suppliers are subject to the limitation of liabilities described in this agreement. The third party supplier is an intended beneficiary of this limitation.” Third party suppliers disclaim all liability for consequential or other indirect damages or for loss of or damage to data or records. 13. General. This EULA will bind and inure to the benefit of each party's successors and assigns, provided that Customer may not assign or transfer this EULA, in whole or in part, without Overland' written consent. This EULA will be governed by and construed in accordance with the laws of the State of California, United States of America, as if performed wholly within the state and without giving effect to the principles of conflict of law. No failure of either party to exercise or enforce any of its rights under this EULA will act as a waiver of such rights. Any waivers or amendments will be effective only if made in writing by non-preprinted agreements clearly understood by both parties to be an amendment or waiver and signed by a representative of the respective parties authorized to bind the parties. If any portion hereof is found to be void or unenforceable, the remaining provisions of this EULA will remain in full force and effect. This EULA is the complete and exclusive agreement between the parties with respect to the subject matter hereof, superseding and replacing any and all prior agreements, communications, and understandings (both written and oral) regarding such subject matter. Any notice, report, approval or consent required or permitted hereunder will be in writing and will be deemed to have been duly given if delivered personally or mailed by first-class, registered or certified US mail, postage prepaid to the respective addresses of the parties. The prevailing party in any action to enforce this EULA will be entitled to recover costs and expenses including, without limitation, reasonable attorneys' fees. A material breach of this EULA adversely affecting Overland's proprietary rights in the Software would cause irreparable injury to Overland for which monetary damages would not be an adequate remedy and that Overland will be entitled to equitable relief in addition to any remedies it may have hereunder or at law. ©2004 Overland Storage, Inc. All rights reserved. Overland® and Overland Storage® are registered trademarks of Overland Storage, Inc. Simply iSCSI, REO SERIES™, REO 100™, REO 1000™, REO 4000™, REO 9000™, ProtectionPAC™, Multi-SitePAC™, AutomationPAC™, CompliancePAC™, BackPAC™, REO SoftKey™, and D2D2T™ are trademarks of Overland Storage, Inc. All other brand names or trademarks are the property of their respective owners. The names of companies and individuals used in examples are fictitious and intended to illustrate the use of the software. Any resemblance to actual companies or individuals, whether past or present, is coincidental. PROPRIETARY NOTICE All information contained in or disclosed by this document is considered proprietary by Overland Storage. By accepting this material the recipient agrees that this material and the information contained therein are held in confidence and in trust and will not be used, reproduced in whole or in part, nor its contents revealed to others, except to meet the purpose for which it was delivered. It is understood that no right is conveyed to reproduce or have reproduced any item herein disclosed without express permission from Overland Storage. Overland Storage provides this manual as is, without warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Overland Storage may make improvements or changes in the product(s) or programs described in this manual at any time. These changes will be incorporated in new editions of this publication. Overland Storage assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of this manual, nor for any problem that might arise from the use of the information in this manual. Overland Storage, Inc. 4820 Overland Avenue San Diego, CA 92123 U.S.A. Tel: +1.858.571.5555 Tel: 1.800.729.8725 (toll free U.S.) Fax: +1.858 571.0982 (general) Fax: +1.858.571.3664 (sales) www.overlandstorage.com Setup Guide Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Chapter 1 Reviewing REO 9000 Concepts and Requirements . . . . . . . . . . . Important Concepts to Understand . . . . . . . . . . Internet SCSI (iSCSI) Protocol . . . . . . . . . . . . Fibre Channel (FC) . . . . . . . . . . . . . . . . Disk-to-Disk-to-Tape (D2D2T) Backup Capabilities . . . Redundant Array of Independent Disks (RAID). . . . . Tape Emulation . . . . . . . . . . . . . . . . . . Logical Volume Management (LVM). . . . . . . . . Reviewing Pre-Installation Requirements . . . . . . . . Network . . . . . . . . . . . . . . . . . . . . . iSCSI Initiators . . . . . . . . . . . . . . . . . . . Setting the SCSI Time-Out Value in Windows Environments . Chapter 2 Chapter 3 11 11 12 13 15 16 16 16 17 17 18 Setting Up the REO 9000 . . . . . . . . . . . . . . . . . . . . . . . 19 Preparing the REO Appliance . . . . . . . . . . . . . Positioning the REO Appliance in a Rack . . . . . . . . Installing the Disk Carriers and Disk Drives . . . . . . . . Connecting the REO Appliance to the Management LAN. Connecting the REO Appliance to the Network . . . . . Connecting External Devices to the REO Appliance . . . Attaching the Power Cords . . . . . . . . . . . . . . 19 21 25 26 27 28 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Understanding What the REO SoftKey Is. . . . . . Backing Up Your REO SoftKey (Pre-Configuration) . Editing the Configuration File (for a non-DHCP or UNIX Management System) . . Connecting the REO SoftKey to the REO Appliance Chapter 4 . . . . . . . . . . . . . . . . . . 11 . . . . . . . . . . . Using the REO SoftKey to Start the REO 9000 . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . . 31 32 . . . . . . . . . . . . . . . . . . 33 36 Configuring the Management System . . . . . . . . . . . . . . . . . 39 Mapping a Network Drive to the REO Appliance (Windows Only). Tracking Configuration Information . . . . . . . . . . . . . Verifying that the Gateway Address and Management Port are Correctly Configured . . . . . . . . . Configuring the GbE Data Ports . . . . . . . . . . . . . . . Entering the Fibre Channel Information . . . . . . . . . . . . Entering the System Information . . . . . . . . . . . . . . . Configuring Logon Information . . . . . . . . . . . . . . . Configuring E-mail Alerts . . . . . . . . . . . . . . . . . . . . . . . . 39 41 . . . . . . 52 55 56 57 58 58 . . . . . . . . . . . . Contents W 5 Overland Storage REO 9000 with ProtectionPAC Software Chapter 5 Chapter 6 Chapter 7 Chapter 8 Chapter 9 Setting the Time and Date Information . . . . . . . . . . . . . . . 60 Configuring the Systems Involved in the Backup Process . . . . . . . . . 61 Mapping a Network Drive to the REO Appliance (Windows Only). . . . Establishing Communication . . . . . . . . . . . . . . . . . . . 61 61 Changing the Volume Setup or Creating Logical Volumes . . . . . . . . 63 Using the Default Volume Setup . . . Changing the Volume Configuration . Selecting JBOD . . . . . . . . . Selecting a RAID Configuration . . Creating Logical Volumes . . . . . . . . . . 63 63 64 65 71 Configuring REO Devices as Disk or Tape Devices . . . . . . . . . . . . 73 Using Devices as Disk Devices . . . . . . . . . . Creating Tape Devices. . . . . . . . . . . . . Changing a Device from Disk to Tape (Standard) Changing a Device from Disk to Dynamic Tape . . . . . 73 73 74 77 Configuring External (SCSI) Devices . . . . . . . . . . . . . . . . . . 81 Detecting External Devices . . . . . . . . . . . . . . . . . . . . Changing the iSCSI Target Name . . . . . . . . . . . . . . . . . 81 84 Associating Targets (Devices) and Initiators 87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 87 . . 89 . . . . 91 92 . . . . 95 96 . . . . 97 97 Working with the REO 9000 . . . . . . . . . . . . . . . . . . . . . . 99 Logging On from Any System with Network Access . Understanding the Summary Pages . . . . . . . Reviewing the REO Device Summary Page . . . Reviewing the Initiator Summary Page . . . . . Reviewing the External Device Summary . . . . Reviewing the External Initiator Summary Page . Reviewing How the Disk Drives are Numbered . . . Understanding What the LEDs Represent . . . . . Powering Down the REO Appliance . . . . . . . Chapter 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 100 101 102 103 103 104 104 105 Expanding Storage Capacity (Scalability) . . . . . . . . . . . . . . . 107 Setting Up Additional REO Appliances in an iSCSI Configuration . . . . . . . . . . . . . . . . . Setting Up Additional REO Appliances in an FC Topology . . Attaching Each REO Appliance Separately . . . . . . . Expanding the Capacity of a REO 9000 by Adding Disk Drives 6 X Contents . . . . . . . . . . . . . . . . . . Understanding How Initiators and Targets (Devices) are Connected Reviewing iSCSI Naming Conventions . . . . . . . . . . . . Reviewing How Targets (REO Devices) and Initiators are Associated . . . . . . . . . . . . . . . . . . Configuring Targets (REO Devices and External Devices) and Initiators . . . . . . . . . . . . . . . . Configuring REO Devices (Targets) and Initiators . . . . . . . . Configuring the iSCSI Initiator with Target (REO Device) and Initiator Assignments. . . . . . . . . Configuring External Devices (Targets) and Initiators . . . . . . Configuring the iSCSI Initiator with Target (External Device) and Initiator Assignments . . . . . . . Backing Up Your REO SoftKey (Post-Configuration) . . . . . . . . Chapter 10 . . . . . . . . . . . . . . . . . . . . . . . . . 107 108 110 112 Setup Guide Appendix A Sharing Access to a REO 9000 Between Multiple Systems . . . . . . . . 115 Configuring Devices as Shared Devices. . . . . . . . . . . . . . . 116 Accessing a Shared Device. . . . . . . . . . . . . . . . . . . . 117 Appendix B Basic Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . 119 Using the SoftKey Reset Option . . . . . . . . . . . . . . Sending the Log Files to Technical Support . . . . . . . . . Unable to Access the REO Appliance . . . . . . . . . . . REO Appliance Does Not Start . . . . . . . . . . . . . . Unable to Log On to the Console . . . . . . . . . . . . . Internet Explorer Does Not Redirect from IP Address on Windows Server 2003 . . . . . . . . . Browser Does Not Reflect Changes Made from Another System or Browser Window . . . . . . . . . . Unable to Connect to the Disks via Windows Explorer . . . . . Perpetual Loop of Audio Alerts . . . . . . . . . . . . . . Disabling the Audio Alarm . . . . . . . . . . . . . . . . Systems Restart When I Map a Disk Drive . . . . . . . . . . I Forgot the New Password or Logon Name . . . . . . . . . Lost or Damaged REO SoftKey or Files Accidentally Deleted from the Key . . . . . . . . . . Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance . . . . . . . . Forcing an Add (JBOD) . . . . . . . . . . . . . . . . Re-Creating a RAID 0 Volume . . . . . . . . . . . . . . Rebuilding a Volume (RAID 5 Without Hot Spare) . . . . . Re-Creating a Hot Spare (RAID 5 With Hot Spares) . . . . . Purchasing a Spare Disk Drive . . . . . . . . . . . . . . . Does the Appliance Automatically Start After a Power Outage? Appendix C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 120 120 121 122 . . . . 123 . . . . . . . . . . . . . . . . . . . . . . . . 124 125 127 127 127 128 . . . . 129 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 129 132 136 141 144 145 . . . . . . . . . . . . . . . . . . . . . . . . 147 148 151 153 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Electromagnetic Emission. . . . . . . . . . . . . . . Notice. . . . . . . . . . . . . . . . . . . . . . Industry Canada . . . . . . . . . . . . . . . . . Industrie Canada . . . . . . . . . . . . . . . . . FCC Notice . . . . . . . . . . . . . . . . . . . Japan Voluntary Control Council for Interference (VCCI) Taiwan BSMI Class A Warning . . . . . . . . . . . . Declaration of Conformity . . . . . . . . . . . . . Appendix E . . . . . Updating the Appliance. . . . . . . . . . . . . . . . . . . . . . 147 Determining the Version of the Product . . . . Checking For and Downloading Updates . . . Installing an Update . . . . . . . . . . . . Updating the Firmware on the FC Controller. Appendix D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 156 156 156 156 157 157 158 Customer Support . . . . . . . . . . . . . . . . . . . . . . . . 159 Registering Your Product . . . . . . . . . . . . . . . . . . . . . 159 Locating Additional Information for Your Product . . . . . . . . . . 160 Glossary and Acronym List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Contents W 7 Overland Storage REO 9000 with ProtectionPAC Software 8 X Contents Preface The Overland Storage REO 9000 Disk-Based Backup-and-Recovery Appliance takes the lag time, expense, and burden out of backing up critical data and works seamlessly within current storage environments. The REO Appliance performs faster than traditional disk-based storage methods and serves as a shared network resource by utilizing highcapacity disks, high-speed Ethernet and Internet SCSI (iSCSI) connectivity, and unique software intelligence capability from Overland Storage. The REO Appliance comes with a standard software package called the ProtectionPAC. The ProtectionPAC software contains all the basic features that you need to configure your REO Appliance to work within your network environment. This document includes information that helps you set up the REO Appliance, including system requirements, questions that you need to answer before installing the product, and installation procedures. Important: If you purchased multiple units, set up (attach and configure) one unit at a time. The target names must be unique within a network; that is, if you are using multiple appliances, you must change the default target names. Also, be aware that the keys are not interchangeable and Overland strongly recommends that you make a backup copy of the files on the keys before and after you configure them. Preface W 9 Overland Storage REO 9000 with ProtectionPAC Software 10 X Preface 1 CHAPTER Reviewing REO 9000 Concepts and Requirements The main steps involved in preparing to set up the REO Appliance include: Step 1 Understanding the concepts of iSCSI, Fibre Channel (FC), disk-to-diskto-tape (D2D2T) backup, redundant array of independent disks (RAID), tape emulation, logical volume management (LVM), and how the REO Appliance fits into the picture. Step 2 Reviewing the requirements that your servers and network must meet to ensure successful installation and operation of the REO Appliance. Important Concepts to Understand To understand the configuration of the backup network and how it fits into the local-area network (LAN) or Fibre Channel (FC) storage-area network (SAN), review the following sections. Internet SCSI (iSCSI) Protocol Internet SCSI (iSCSI) is a standard protocol for universal access to shared storage devices over standard, Ethernet-based transmission control protocol/Internet protocol (TCP/IP) networks. The connectionoriented protocol transports SCSI commands, data, and status across an IP network. For more information, see Glossary and Acronym List on page 163. iSCSI Architecture The iSCSI architecture is based on a client-server model. The client is a host system that issues requests to read or write data. iSCSI refers to a client as an initiator. The server is a resource that receives and executes client requests. iSCSI refers to a server as a target. File servers, which store the programs and data files shared by users, normally play the role of server. With the REO Appliance, the application and backup servers within your network act as clients or initiators and the REO Appliance acts as a server or target. The initiators can either be software drivers or iSCSI host bus adapters (HBAs) on the server that is being backed up. Reviewing REO 9000 Concepts and Requirements W 11 Overland Storage REO 9000 with ProtectionPAC Software Fibre Channel (FC) Instead of, or in addition to, using iSCSI and the TCP/IP protocol to transmit information over a network, you also have the option of using a SAN that makes use of the FC and Small Computer System Interface (SCSI) protocols. The FC protocol uses two additional protocols to communicate at the hardware level: Fibre Channel Arbitrated Loop (FCAL), which communicates with hubs, and Fibre Channel Switched (FCSW), which communicates with switches. The SCSI protocol provides the communication link at the higher level, between the hardware and the software. You can use all three basic FC SAN topologies with the REO Appliance: Point-to-point. This topology provides a direct connection between two N_Ports. Arbitrated loop. In an arbitrated loop, NL_Ports and FL_Ports are daisy-chained with hubs, which means that only one device can send data at a time. Switched fabric. Switched fabric consists of one or more switches that are interconnected, and multiple nodes connected to the switches. The REO Appliance supports the following types of ports for FC: Port Type Represents Associated Topology N_Port Node Port Connects point-to-point or to F_Port NL_Port Node Loop Port N_Ports that can connect to an arbitrated loop FC uses strict naming conventions to support unique, 64-bit names for the worldwide node name (WWNN) and the worldwide port name (WWPN). These names are pre-assigned by the manufacturers of the different hardware components used in an FC. 12 X Reviewing REO 9000 Concepts and Requirements Setup Guide Disk-to-Disk-to-Tape (D2D2T) Backup Capabilities The REO Appliance is a storage resource used by a single backup server or shared by multiple backup servers using an Ethernet or FC network. By using standard backup software, you can copy backup data that resides on the REO Appliance to tape for long-term data retention. The following illustration shows application servers sending backup data over a 10/100 or Gigabit Ethernet (GbE) LAN to backup servers sharing REO Appliance D2D storage over GbE or FC. Application servers Ethernet/FC Backup Network, 10/100/1000 BaseT Ethernet Storage-Area Network, GbE or FC Ethernet/FC Backup Server Tape REO In addition to being part of the LAN, the backup servers, and the REO Appliance are part of the GbE backup SAN. Important Concepts to Understand W 13 Overland Storage REO 9000 with ProtectionPAC Software The following diagrams show two different ways of configuring a REO Appliance with multiple backup servers. Management browser interface (console) LAN Server 1 Server 2 Server 3 Server 4 Server 5 Server 6 Server 7 Server 8 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 Backup server 10/100 Management Backup server SCSI SCSI Tape sub-system Tape sub-system GbE or FC Switch REO 14 X Reviewing REO 9000 Concepts and Requirements Setup Guide Management browser interface (console) LAN Server 1 Server 2 Server 3 Server 4 Server 5 Server 6 Server 7 Server 8 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 GbE or 10/100 Backup server 10/100 Management Backup server SCSI SCSI Tape sub-system Tape sub-system REO Redundant Array of Independent Disks (RAID) RAID provides convenient, low-cost, reliable storage by saving data on more than one disk drive simultaneously. If one disk drive in a RAID 5 configuration becomes unavailable, the others continue to work in a degraded state, thus avoiding downtime for users. Note: Because RAID 5 is designed for data protection, you might see performance degradation when compared to JBOD operations. RAID allows you to group the individual disk drives on the REO Appliance into logical disk drives of different sizes. You can configure your REO Appliance to create two physical RAID volumes by selecting either of the following RAID options: RAID 0. This configuration uses striping, which provides enhanced performance and volume-level capacity. It divides the data into blocks and writes each block to a separate disk drive, which improves performance by dispersing the input and output load. RAID 0 does not provide data redundancy. RAID 5. This configuration uses striping and distributed parity, which provides a balance between performance and availability. In addition to dividing the data into blocks as described for RAID 0, the parity information is also striped across the disks. If one of the disk drives fails, you can use the parity information to rebuild the lost data. In addition to using either of the preceding RAID configurations, you can also take advantage of logical volume management (LVM) and create logical volumes from the data pool. Important Concepts to Understand W 15 Overland Storage REO 9000 with ProtectionPAC Software If you use a RAID 5 configuration, you can also set aside a disk drive for each physical host (controller); that is, you can create a hot spare. These disk drives remain in standby mode, and you can use them immediately if another disk fails. Tape Emulation The ProtectionPAC software includes two tape emulation features, which you can use to create virtual linear tape-open (LTO-2) tape devices that provide 2-to-1 compression ratios with typical data sets (actual performance might vary with application). When you use tape emulation, the disk drives on the REO Appliance appear to your backup software as LTO-2 tape drives, which simplifies the setup process while simultaneously providing data compression and the attributes of backing up data to disk. Depending on the configuration that you use, you get a different number of virtual LTO-2 devices. In the just-a-bunch-of-disks (JBOD) configuration, you can have up to 24. If you use RAID 0 or 5 without logical volumes, you can have four. If you use logical volumes with RAID 0 or 5, you can create up to 64 virtual LTO-2 devices. If you decide to use tape emulation, you also have the option of using fixed-length (Tape) or dynamic-length (Dynamic Tape) devices. To take advantage of the Dynamic Tape option, you must use logical volumes, which is described in the next section. Using Dynamic Tape lets you create devices that adjust to the size of individual backup jobs. Logical Volume Management (LVM) With LVM, you can combine the two physical RAID volumes into multiple logical volumes (partitions) of different sizes and assign logical unit numbers (LUNs) to represent the different volumes, or REO devices. This feature lets you set up and assign devices to different systems according to your needs and the configuration and type of storage network that you use. Using this feature in the ProtectionPAC software, you can create up to 64 LUNs, and you can reassign space allocation for disk or standard (not dynamic) virtual tape devices, in 1 gigabyte (GB) increments, on the fly. Reviewing Pre-Installation Requirements Before attempting to operate the REO Appliance with your backup servers, verify that your network meets the minimum requirements specified in the following sections. Important: If you purchased multiple units, set up (attach and configure) one unit at a time. The target names must be unique within a network; that is, if you are using multiple appliances, you must change the default target names. Also, be aware that the keys are not interchangeable and Overland strongly recommends that you make a backup copy of the files on the keys before and after you configure them. 16 X Reviewing REO 9000 Concepts and Requirements Setup Guide Network For best results, Overland Storage strongly recommends that you use a dedicated GbE network to share the storage resources on the REO Appliance among multiple backup servers. To ensure optimum performance, always use the appropriate patch cables to connect the REO Appliance to the backup-server storage network. To select the appropriate cables, use the following guidelines: If you intend to use GbE, you must use Category 5E (or better) cables for GbE connections. You can use either straight-through or cross-over cables. If you intend to connect the REO Appliance to a 100 BaseT network, use CAT 5 (or better) shielded (screened) or unshielded 100-ohm twisted-pair RJ-45 network cables. Also: If you intend to connect the Management Port, which is a 10/100 port, to an application or backup server via a switch, you must use a straight-through cable. If you intend to connect the Management Port directly to your application or backup server (without a switch), you must use a cross-over cable. The maximum length of cable for any Ethernet-based network connection is 328 feet (100 meters). Note: For smaller environments, you can attach the REO Appliance directly to a single application or backup server by using standard Category 5E cables without the use of a switch. iSCSI Initiators iSCSI initiators are required to communicate with the iSCSI targets (REO Devices) on the REO Appliance. Each backup server that will interface with the REO Appliance must be equipped with a software- or hardware-based initiator. The REO Appliance supports any computing platform with an available iSCSI initiator, either in software or using an iSCSI HBA (it must be iSCSI draft 20/version 1.0). Reviewing Pre-Installation Requirements W 17 Overland Storage REO 9000 with ProtectionPAC Software Setting the SCSI Time-Out Value in Windows Environments If you intend to use your REO Appliance in a Windows environment, be aware that there are certain operating conditions in which time-out errors might occur. These errors usually result in the system reporting a disk failure for the associated REO Appliance disk drive or drives. (These errors might be reported as iSCSIPrt errors in the System Log of the Event Viewer. Examples include an Event ID 9 [Target did not respond in time for a SCSI request…] and Event ID 39 [Initiator sent a task management command to reset the target…]. Other symptoms might include “Lost Delayed Write Data” system error messages or similar error messages related to the REO Appliance disk drives.) The reason that these disk time-out errors can occur is because the default I/O time-out value for Windows is 20 seconds, which is not sufficient to support the default iSCSI protocol time-out value of 60 seconds. When you install and set up your REO Appliance, Overland strongly recommends that you set this value to 60 seconds. To set the time-out value to 60 seconds 1 On the Windows system, run regedit. Warning: If you edit the registry incorrectly, you might cause serious problems that require you to reinstall your operating system. Edit the registry at your own risk. Prior to making any changes, refer to the following Microsoft Knowledge Base article: http://support.microsoft.com/default.aspx?scid=kb;en-us;322755 2 In HKEY_LOCAL_MACHINE\System\CurrentControlSet\ Services\Disk, edit or add the TimeOutValue entry to set it to 60 seconds in decimal format ((0000003c in hexadecimal). To edit the value for the TimeOutValue entry if it already exists, double-click the entry, enter the new value, and click OK. To add the TimeOutValue entry if it does not yet exist, right-click anywhere in the list of values, and then click New > DWORD value. Name the new value TimeOutValue, and then double-click it to edit the setting. 18 X Reviewing REO 9000 Concepts and Requirements 2 Setting Up the REO 9000 CHAPTER The main steps involved in setting up the REO Appliance include: Step 1 Unpacking the REO Appliance, and reviewing safety guidelines. Step 2 If you intend to position the REO Appliance in a rack, attaching the required components. Step 3 Connecting the REO Appliance to the management LAN. Step 4 Connecting the REO Appliance to the application and backup servers, SAN for the backup servers, or FC. Step 5 Connecting external SCSI devices. Step 6 Attaching the power cords. Preparing the REO Appliance Caution: Due to the weight of each rack-mounted unit when it is fully extended, you should install units from the bottom up. Extending a unit that has empty spaces beneath it might cause the rack to tip forward or might cause personal injury. Overland Storage recommends that two people support and slide the unit in the rack. Vorsicht: Aufgrund des Gewichtes eines Gerätes, welches für den Einbau in ein Rack gedacht ist, empfehlen wir Ihnen, dieses von unten nach oben in das Rack zu installieren. Wenn Sie ein Gerät aus dem Rack heraus ziehen, könnte es Ihnen entgleiten und so zu Verletzungen führen. Wir empfehlen den Ein- und Ausbau des Gerätes durch zwei Personen. Setting Up the REO 9000 W 19 Overland Storage REO 9000 with ProtectionPAC Software 1 Unpack the REO Appliance. The shipping container contains the following: Overland Storage appliance chassis Depending on which version of the product that you purchased, either 12 or 24 disk carriers and disk drives Power cords (U.S.) (Approved cord sets shall be used in countries outside North America.) Appliance face-plate REO SoftKey Rack-mount hardware Documentation CD-ROM and poster 2 Review the following guidelines prior to positioning the REO Appliance physically within your network. Make sure that the REO Appliance is accessible. Make sure there is unrestricted air flow around the unit and through the vents in the sides and rear of the case. Route external cables so that they can be connected easily without blocking air vents or impeding air flow. Protect the REO Appliance from extreme temperature and humidity. Overland Storage recommends that you install the REO Appliance in a clean, air-conditioned environment where water and moisture cannot enter the case of the REO Appliance. Keep the air as free from dust as possible. Protect the REO Appliance from physical shock and vibration. Make sure that the inlet air temperature within the rack remains below the specified limit of 95°F (35°C). Keep the REO Appliance and cabling away from sources of electrical noise such as elevator shafts, stereo speakers, microwave ovens, air conditioning units, and even telephones. Electromagnetic fields can interfere with the signals on copper cabling and introduce errors, therefore slowing down the network. 20 X Setting Up the REO 9000 Setup Guide Positioning the REO Appliance in a Rack Caution: Due to the weight of each rack-mounted unit when it is fully extended, you should install units from the bottom up. Extending a unit that has empty spaces beneath it might cause the rack to tip forward or might cause personal injury. Overland Storage recommends that two people support and slide the unit in the rack. Vorsicht: Aufgrund des Gewichtes eines Gerätes, welches für den Einbau in ein Rack gedacht ist, empfehlen wir Ihnen, dieses von unten nach oben in das Rack zu installieren. Wenn Sie ein Gerät aus dem Rack heraus ziehen, könnte es Ihnen entgleiten und so zu Verletzungen führen. Wir empfehlen den Ein- und Ausbau des Gerätes durch zwei Personen. To install the unit in a rack 1 Separate each set of slides as follows: Pull the outer slide toward the rear, along with the intermediate slide, until the inner slide-lock engages the intermediate slide. REO90002 Continue to pull the outer slide towards the rear until the outer slidelock engages the intermediate slide. To permit the intermediate slide to continue to move toward the rear, press the inner slide-lock button. Continue to move the outer and intermediate slides toward the rear until they are separated from the inner slide. REO90005 Positioning the REO Appliance in a Rack W 21 Overland Storage REO 9000 with ProtectionPAC Software 2 Locate the screw holes in the front and rear rails of the rack where the REO Appliance slides will be installed. The unit uses 5U of rack space. Location of rails and mounting hardware Nut plates, slide rails, bar nuts, and mounting screws REO90007 REO90051 3 Fasten each outer slide by using 10-32 screws (with washers, if needed) and one nut plate. 22 X Setting Up the REO 9000 Setup Guide Select slots in the mounting brackets so that the length of the assembly equals the distance between the front and rear rails of the rack. Nut Plate REO90063 Note: When fastening the adjustable bracket, allow room for the slide to pass by the inside of the rack. 4 Tighten all the screws. 5 If they are not already locked in the extended position, pull the intermediate slides toward the front (out of the rack) so that they lock in the extended position. REO0065 Caution: The disk drives for the REO Appliance are located in the front of the unit. The result being the majority of weight is distributed to the front of the REO Appliance. This next step should be performed by at least two people, or by using a mechanical lift. Make certain that when the REO Appliance is fully extended that a force of 20% of the rack’s weight, but not more than lb. (Kg), applied in any direction other than upwards, does not cause the rack to overbalance. Positioning the REO Appliance in a Rack W 23 Overland Storage REO 9000 with ProtectionPAC Software 6 At the front of the rack, lift the REO Appliance to its installed height, engage the inner slides mounted on the REO Appliance with the intermediate slides protruding from the rack, and slide the REO Appliance toward the rack until the inner slide-lock engages the intermediate slide. This leaves the entire REO Appliance protruding from the rack, locked in position, supported by the slide rails. Caution: With one unit installed in the rack and in the extended position, support might be required (to prevent the rack from tipping) until the unit is pushed completely into the rack. (The unit is shown in the middle of the rack for clarity.) REO90003 7 Press inward (toward the chassis) on each of the inner slide-locks to permit the intermediate slides to move toward the rack. 8 Slide the REO Appliance in and out several times, ensuring that the inner and outer slide locks engage, and that the REO Appliance chassis does not bind against the slides. REO90001 24 X Setting Up the REO 9000 Setup Guide 9 Slide the REO Appliance into the rack, and attach the captive screw on each panel extension (left and right sides) to the rack and nut plate. REO90006 Installing the Disk Carriers and Disk Drives The disk carriers, which contain the disk drives, are packaged separately, which allows you to insert them into the chassis after you have installed the chassis in the rack. 1 Remove the package of desiccant from each slot in the chassis. 2 Insert the first disk carrier in to the applicable slot in the chassis. 3 Close the disk carrier by doing the following: a Make sure that the lever is in its fully extended, open position. b Press the right side of the carrier into the slot. c Press the lever in. Pressing the lever in draws the carrier fully into the slot and locks it in place. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 4 Repeat these steps for each disk carrier. 5 Attach the appliance face-plate. Installing the Disk Carriers and Disk Drives W 25 Overland Storage REO 9000 with ProtectionPAC Software Connecting the REO Appliance to the Management LAN X Using the Management Port (10/100), connect the REO Appliance to your LAN via the twisted-pair network cables. Management Port 26 X Setting Up the REO 9000 Setup Guide Connecting the REO Appliance to the Network Use the following instructions to connect your REO Appliance to your backup servers, SAN, or FC switch. 1 For iSCSI connectivity, use Data Port 1 to connect the REO Appliance to a backup server via the twisted-pair network cables. Data Port 2 Data Port 1 2 For additional iSCSI connectivity, use Data Port 2 to connect the REO Appliance to a second backup server via the twisted-pair network cables. You can connect backup servers to the REO Appliance by using a directconnect cable or by using a GbE switch. 3 If you are using FC, connect the Fibre Channel Ports on the rear of the REO Appliance to your FC switch or hub. The Fibre Channel ports on the back of the REO Appliance are numbered port 0 (bottom) and port 1 (top). Port 1 Port 0 Connecting the REO Appliance to the Network W 27 Overland Storage REO 9000 with ProtectionPAC Software Connecting External Devices to the REO Appliance The REO Appliance includes two Ultra320 SCSI ports, which support SCSI devices such as medium changers and tape drives. You can use a chain formation to assign up to 15 SCSI IDs to each port. To connect SCSI devices to your REO Appliance X On the rear of the REO Appliance, attach the applicable devices to the SCSI ports. You must use an external 68-pin SCSI cable that includes a male connect with thumbscrews to connect a device to the port. (This cable is not included with the REO Appliance.) SCSI port 0 SCSI port 1 Attaching the Power Cords 1 Attach all four power cords to the REO Appliance. 2 Plug the power cords in to an AC power source (do not turn the power on). Important: You must connect and use all four power cords; if one of the cords is disconnected or malfunctioning, the REO Appliance beeps repeatedly until the situation is resolved. Overland Storage recommends that you use separate power mains for the power sources. If you are not using Dynamic Host Configuration Protocol (DHCP), it is critical to the configuration process that you refrain from enabling power to the REO Appliance before completing the configuration steps specified in the next chapter. Power problems can be the cause of serious failures and downtime in your network. Ensure that the power input to your system is clean and free from sags and surges to avoid unforeseen network outages. Overland Storage strongly recommends that you install power conditioning and an adequately rated uninterruptible power supply (UPS), especially in areas prone to blackouts, power dips, and electrical storms. The REO Appliance is intended to be grounded. Ensure it is connected to earth ground during normal use. Installing proper grounding helps to avoid damage from lightning and power surges. 28 X Setting Up the REO 9000 Setup Guide Each power supply contains: A socket for insertion of an AC line cord. A two-color LED for indicating the status of the power supply. When AC is applied to the supply and standby voltages are available, the LED becomes red. When all outputs are available, the LED becomes green. If the power supply fails, the LED becomes red. A latch for releasing the power supply from the REO Appliance. A handle for pulling the power supply out of the REO Appliance. A pair of fans for preventing the power supply from overheating. A feature that verifies the following (if not detected, an alarm signal sounds): All output voltages V1 to V5 are within regulation. The fans are operating normally. The internal temperature of the power supply is normal. Fans Socket Release latch Thumbscrew Extraction handle 3 Complete the steps outlined in the next chapter, Using the REO SoftKey to Start the REO 9000 on page 31. Attaching the Power Cords W 29 Overland Storage REO 9000 with ProtectionPAC Software 30 X Setting Up the REO 9000 3 CHAPTER Using the REO SoftKey to Start the REO 9000 The main steps involved in using the key to start the REO Appliance include: Step 1 Making a backup copy of the key. Step 2 If your network does not use DHCP, manually editing the configuration and network files on the key. Step 3 Connecting the key to the REO Appliance. Understanding What the REO SoftKey Is The REO SoftKey is a removable USB disk drive on a key ring. It contains the software and settings required for configuring the REO Appliance and must be inserted in the REO Appliance whenever you restart it (because the REO Appliance uses a Linux-based OS, the key is formatted using the virtual file allocation table [VFAT]). You can also use the REO SoftKey to download and install updates when they become available. Important: If you purchased multiple units, note that the keys are not interchangeable The simplest configuration can be achieved when your LAN uses DHCP on its own subnetwork (subnet). If your LAN does not use DHCP, you must manually edit the configuration file located on the REO SoftKey before continuing. Using the REO SoftKey to Start the REO 9000 W 31 Overland Storage REO 9000 with ProtectionPAC Software Backing Up Your REO SoftKey (Pre-Configuration) Make a backup copy of all the files on the REO SoftKey before and after you configure it. 1 Remove the cap from the REO SoftKey, and insert it into a USB port on a Windows 2000, 2003, or XP system that contains active virusprotection software. Note: If you have not previously installed a USB mass-storage device, Windows displays a dialog box that indicates it has found new hardware and will automatically install the necessary drivers on your system. 2 Double-click My Computer on your desktop (or use Windows Explorer), and browse to the software-key disk drive. The name of this disk drive varies based on your system configuration, but it will be called something like Removable Disk (G:). Make a backup copy of all the folders and files contained on the REO SoftKey. 3 Make a backup copy of all the data on the REO SoftKey, and store the copy in a secure location. 4 To determine your next step, choose one of the following: If your LAN uses DHCP, continue from step 1 under Connecting the REO SoftKey to the REO Appliance on page 36. If your LAN does not use DHCP, complete the steps outlined in the next section, Editing the Configuration File (for a non-DHCP or UNIX Management System), before continuing. 32 X Using the REO SoftKey to Start the REO 9000 Setup Guide Editing the Configuration File (for a non-DHCP or UNIX Management System) 1 With the key still inserted into a USB port on a Windows 2000, 2003, or XP system that contains active virus-protection software, browse to the software-key disk drive. 2 Open the ipkey folder, and locate the ifcfg-eth0 file. The ifcfg-eth0 is the configuration file for the Management Port on the REO Appliance. Open the ipkey folder, right-click ifcfg-eth0, and click Properties. 3 Right-click the ifcfg-eth0 file, and click Properties. 4 On the General tab, if the Read-only check box is selected, clear it, and then click OK; otherwise, click Cancel. 5 Right-click the ifcfg-eth0 file again, click Open With, and then select WordPad (or a comparable text editor). Tip: Overland Storage recommends that you use WordPad, because it displays the configuration information in an easy-to-use format. Editing the Configuration File (for a non-DHCP or UNIX Management System) W 33 Overland Storage REO 9000 with ProtectionPAC Software 6 Make the following changes: Change the BOOTPROTO field from dhcp to static (make sure that you enter it in lowercase). After the BOOTPROTO line, enter lines for IPADDR, NETMASK, NETWORK, and BROADCAST, and, in each corresponding field, enter the IP address you selected for the management interface for the REO Appliance on your network. Note: You do not need to modify the other fields at this time. 7 Save the file; when asked if you want to replace the existing file, click Yes. 8 In the ipkey folder, locate the network file. Locate and open the network file. 9 Right-click the network file, click Open With, and then select WordPad. Change GATEWAY to the applicable IP address. 34 X Using the REO SoftKey to Start the REO 9000 Setup Guide 10 Change the contents of the GATEWAY field to the applicable IP address, and save and exit the file. Note: If you are using a direct connection (private network), leave the GATEWAY address as 0.0.0.0. 11 Remove the REO SoftKey from the system by doing the following: a Double-click the Unplug or Eject Hardware icon, located in the system tray (lower-right corner of the task bar). b In the Unplug or Eject Hardware dialog box, select the device you want to unplug (the key is identified as USB Mass Storage Device), and click Stop. Select USB Mass Storage Device, and then click Stop. c In the Stop a Hardware device dialog box, select USB Mass Storage Device, and then click OK. Select USB Mass Storage Device again, and then click OK. d When the message appears that indicates it is safe to remove the device, click OK, and remove the REO SoftKey. 12 Complete the steps outlined in the next section, Connecting the REO SoftKey to the REO Appliance. Editing the Configuration File (for a non-DHCP or UNIX Management System) W 35 Overland Storage REO 9000 with ProtectionPAC Software Connecting the REO SoftKey to the REO Appliance 1 Insert the REO SoftKey into the USB port located on the back of the REO Appliance. Insert the key. 2 To turn the REO Appliance on, press and hold the power button for approximately 1 second. Important: If you purchased multiple units, enable power to only one unit at this point; you must set up one unit at a time. 36 X Using the REO SoftKey to Start the REO 9000 Setup Guide The power button is located on the front of the appliance. The power button is a momentary contact device that needs to be pressed and held for about 1 second to begin the power-up sequence. Press and hold the power button for 1 second. After you turn the power on, the REO Appliance performs a self-test process and loads the necessary information from the REO SoftKey. Following successful completion of the self-test, which takes several minutes, you should hear 3 beep tones. 3 Listen for the series of 3 beep tones spaced about 1 second apart. Important: On startup, the REO Appliance might reach an error state and begin an endless loop of alerts. The pattern (2 beeps separated by a 1-second delay) repeats every 4 seconds. If this occurs, turn the appliance off and then back on. For more information, see Perpetual Loop of Audio Alerts on page 127. 4 After you hear the beep tones, proceed to the configuration steps outlined in the next chapter, Configuring the Management System on page 39. If you are unable to hear the tones in your physical environment, wait approximately five minutes before continuing. Note: You must leave the REO Appliance on and the REO SoftKey inserted while completing the configuration process for your application and backup servers. Connecting the REO SoftKey to the REO Appliance W 37 Overland Storage REO 9000 with ProtectionPAC Software 38 X Using the REO SoftKey to Start the REO 9000 4 CHAPTER Configuring the Management System The main steps involved in configuring the management system include: Step 1 Establishing communication with the REO Appliance by mapping it to a drive letter (Windows only). Step 2 Verifying that the gateway and Management Port information are correct. Step 3 Entering the GbE Data Port, Fibre Channel, and system information. Step 4 Setting up your logon information. Step 5 Configuring e-mail alerts. Step 6 Setting the applicable time zone information. The images shown in the following sections might appear slightly different if you are using a different browser or a UNIX-based system. Mapping a Network Drive to the REO Appliance (Windows Only) To access the components used for installation and configuration of the REO Appliance, you must map a network drive from the REO Appliance to the system that will operate the REO Appliance console. 1 Make sure that REO SoftKey is still inserted in a USB port on the REO Appliance. 2 Right-click My Computer on your desktop, and click Map Network Drive. Configuring the Management System W 39 Overland Storage REO 9000 with ProtectionPAC Software 3 Use the default network drive displayed or select another drive from the list. Tip: For consistency, Overland Storage recommends that you select a drive letter, such as drive Z, that is available to all systems on the backup network. 4 In the Folder box of the Map Network Drive dialog box, type \\REO\programs, and make sure that the Reconnect at login box is cleared. Note: Because the folder might not be visible if you use the Browse button, Overland Storage recommends that you type \\REO\programs directly in the Folder text box. 5 Click Finish. 6 If prompted for your name and password, enter the following in casesensitive format: Logon Name: Administrator Password: system 40 X Configuring the Management System Setup Guide Tracking Configuration Information As you complete the configuration process by following the steps outlined in this and subsequent chapters, use the following forms to note what information you enter. Important: This information will be useful if you have to reconfigure the REO Appliance for any reason, such as a lost or damaged REO SoftKey. Network Configuration Page Default Gateway IP Address: Management Port IP Address: Subnet Mask: Network Address: Broadcast Address: DHCP: Data Port 1 IP Address: Subnet Mask: Network Address: Broadcast Address: Data Port 2 IP Address: Subnet Mask: Network Address: Broadcast Address: Fibre Channel Configuration WWPN(0) Link Speed: Link Topology: WWPN(1) Link Speed: Link Topology: System Configuration Page System Information Workgroup/Domain Name: REO Name: REO Description: E-mail Notification Mail Address: From Address: Address for All: Address for Critical: Alert Frequency: Tracking Configuration Information W 41 Overland Storage REO 9000 with ProtectionPAC Software REO Device Configuration Page REO Device ID 0 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 1 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 2 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 3 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 4 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 5 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 6 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 7 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: 42 X Configuring the Management System Setup Guide REO Device Configuration Page (continued) REO Device ID 8 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 9 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 10 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 11 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 12 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 13 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 14 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 15 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: Tracking Configuration Information W 43 Overland Storage REO 9000 with ProtectionPAC Software REO Device Configuration Page (continued) REO Device ID 16 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 17 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 18 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 19 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 20 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 21 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 22 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 23 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: 44 X Configuring the Management System Setup Guide REO Device Configuration Page (continued) REO Device ID 24 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 25 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 26 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 27 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 28 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 29 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 30 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 31 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: Tracking Configuration Information W 45 Overland Storage REO 9000 with ProtectionPAC Software REO Device Configuration Page (continued) REO Device ID 32 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 33 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 34 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 35 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 36 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 37 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 38 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 39 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: 46 X Configuring the Management System Setup Guide REO Device Configuration Page (continued) REO Device ID 40 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 41 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 42 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 43 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 44 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 45 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 46 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 47 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: Tracking Configuration Information W 47 Overland Storage REO 9000 with ProtectionPAC Software REO Device Configuration Page (continued) REO Device ID 48 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 49 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 50 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 51 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 52 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 53 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 54 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 55 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: 48 X Configuring the Management System Setup Guide REO Device Configuration Page (continued) REO Device ID 56 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 57 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 58 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 59 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 60 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 61 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 62 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: REO Device ID 63 Device Type: Disk, Tape, Dyn. Tape ShareDevice: Yes or No Tape Compression: Yes or No Dyn. Tape Max. Size: iSCSI Target Name: Connection Type: iSCSI or FC iSCSI Initiator Name: Initiator IP Address: Tracking Configuration Information W 49 Overland Storage REO 9000 with ProtectionPAC Software External Device Configuration Page REO Device ID 160 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 168 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 161 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 169 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 162 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 170 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 163 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 171 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 164 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 172 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 165 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 173 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 166 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 174 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 167 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: 50 X Configuring the Management System Setup Guide External Device Configuration Page (continued) REO Device ID 175 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 183 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 176 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 184 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 177 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 185 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 178 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 186 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 179 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 187 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 180 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 188 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 181 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 189 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: REO Device ID 182 iSCSI Target Name: iSCSI Initiator Name: Initiator IP Address: Tracking Configuration Information W 51 Overland Storage REO 9000 with ProtectionPAC Software Verifying that the Gateway Address and Management Port are Correctly Configured The Default Gateway is the IP address that provides entrance into the network to which the REO Appliance is assigned. The Management Port connects the REO Appliance to the management system, which you use for network management on the LAN. Important: Remember that the Management Port and both Data Ports must be on separate subnets. 1 Using the management system, access the mapped drive \\REO\programs. 2 To open the REO Appliance console in your Web browser, double-click the Overland.html file. Tip: After you have initially configured your REO Appliance, if you are not using DHCP, you can also access the interface by typing the IP address assigned to the Management Port for the REO Appliance. To launch the console, double-click Overland. 52 X Configuring the Management System Setup Guide 3 If you are prompted for your name and password, enter the following in case-sensitive format: Logon Name: Administrator Password: system The REO Appliance console appears. Tip: To access online help on any of the pages in the console, click Help under System Menu or click the Help button that appears on each of the pages. To access help at any time, click Help. Verifying that the Gateway Address and Management Port are Correctly Configured W 53 Overland Storage REO 9000 with ProtectionPAC Software 4 In the left pane, under System Menu, click Network Configuration. Click Network Configuration. 5 If you are not using DHCP, in the Default Gateway section of the right pane, make sure that the correct IP Address appears. If DHCP is disabled, the IP address and other information is completed using information from the configuration file that you previously modified (for more information, see Editing the Configuration File (for a non-DHCP or UNIX Management System) on page 33). Verify that this is the correct information for your network. 54 X Configuring the Management System Setup Guide 6 In the Management Port section, verify the following: If your network uses DHCP (recommended), make sure that Enable is selected. The Management Port is automatically configured when DHCP is enabled. This is the default setting. (If you are using DHCP, the system displays the addresses that are currently being used.) If your network does not use DHCP or you are using a UNIX-based system, make sure that the correct addresses appear and that Disable is selected. 7 Continue the configuration process by configuring the GbE data ports as described in the next section. Configuring the GbE Data Ports The GbE data ports are used for block-level data transport between your backup servers and the REO Appliance. Data Port 1 and Data Port 2 are fully interchangeable prior to configuration. Important: Remember that the Management Port is on the LAN (a 10/100 network); use Data Port 1 and Data Port 2 on separate subnets of the backup network. Data Port 1 and Data Port 2 each require an available static IP address within their respective subnets. If you want to manage the REO Appliance from the same port, use the GbE (Data Port 1 or 2) IP address. Entering this IP address in your browser displays the REO Appliance software console. If you have one or two backup servers, you can connect each one directly to one of the data ports on the REO Appliance. The backup servers must have a GbE port. If you have more than two backup servers, you must make these connections through a GbE switch. To configure the GbE ports 1 In the right pane, scroll down below the Management Port section to locate the Data Port 1 and Data Port 2 sections. 2 In the Data Port 1 section, enter the following: IP Address. Using dotted decimal notation, enter an available static IP address that falls within the Data Port 1 subnet. An example of an address is: 192.168.1.4. Subnet Mask. Using dotted decimal notation, enter the subnet address. An example of an address is: 255.255.0.0. Tip: If you change one of these settings, such as the IP Address, you might need to reconnect to the server via your Web browser. Configuring the GbE Data Ports W 55 Overland Storage REO 9000 with ProtectionPAC Software 3 Click Apply. 4 Repeat these steps for Data Port 2 using an IP address that falls within the Data Port 2 subnet. Tip: Overland Storage recommends that you use a ping command to ensure that the management system sees each port on the REO Appliance. 5 If you purchased the FC-enabled REO Appliance, continue the configuration process by entering the FC information described in the next section; otherwise, proceed to the subsequent section, Entering the System Information on page 57. Entering the Fibre Channel Information 1 In the right pane, scroll down to the Fibre Channel Configuration section. 2 For each FC port (the REO Appliance provides two), select the applicable settings from the Set Link Speed and Set Link Topology lists. For link speed, select Auto, 1 GB, or 2 GB. For topology, select Auto, Fabric/Point-to-Point (N_Port), or Loop (NL_Port). Select the applicable settings for each Fibre Channel port. 3 Click Apply. 4 Continue the configuration process by configuring the system information as described in the next section. 56 X Configuring the Management System Setup Guide Entering the System Information 1 In the left pane, under System Menu, click System Configuration. Click System Configuration. 2 In the System Information section of the right pane, enter the following: Workgroup/Domain Name. Enter the workgroup or domain name assigned by your network administrator. REO Name. Enter up to 16 characters to name the REO Appliance. You can use letters or a mixture of letters and numbers, and you can also use hyphens (-). Overland Storage recommends that you change this name (the default is REO), especially if you use multiple REO Appliances in your network. REO Description. Enter up to 20 alphabetical or numerical characters (or a combination of the two) to describe the appliance. Change these entries, especially if you use multiple appliances. 3 Click Apply. 4 Continue the configuration process by entering the logon information described in the next section. Entering the System Information W 57 Overland Storage REO 9000 with ProtectionPAC Software Configuring Logon Information Using the Logon Information section, you can change your logon name and password, which Overland Storage recommends that you do during the initial configuration process. If you choose to keep Administrator as your logon name, Overland Storage strongly recommends that you change the password to protect your network from unauthorized users. 1 In the right pane, scroll down below the System Information section to locate the Logon Information section, and enter the following in casesensitive format: User Name. (required) Enter a new logon name using up to 30 alphabetical or numerical characters or a combination of the two. Password. (optional) Enter a new password using up to 30 alphabetical or numerical characters or a combination of the two characters (do not use spaces or Ctrl-key characters). Retype Password. Enter the password again. 2 Click Apply. 3 Continue the configuration process by entering the e-mail information described in the next section. Configuring E-mail Alerts The REO Appliance continuously monitors its performance and routinely checks for disk failures. If you use the messaging option, an e-mail is sent whenever the Status of a volume on the REO Device Summary page becomes anything other than Up (for example, changes to REBUILDING). Tip: You can also use the ALARM MESSAGES section on the Physical Volume Management page to see more information. The messages (also known as asynchronous event notifications) that appear on this page display additional information about each disk that might not be displayed in an alert e-mail. You can specify whether the REO Appliance should send an alert once or repeat the message until the issue is resolved. Each alert that is sent reports the status of all volumes on the REO Appliance. If you configure the option to use an Alert Frequency of five minutes or more, the alerts will be numbered. If your mail server is able to send e-mail messages outside the company, you can also set up messaging to notify Overland Storage Technical Support automatically whenever a critical error occurs. 58 X Configuring the Management System Setup Guide To configure messaging 1 In the right pane, scroll down below the Logon Information section to locate the E-mail Notification section, and enter the following: Mail Address. Using dotted decimal notation, enter the IP address of your incoming mail server. From Address. Enter the e-mail address from which the alert will be sent. This address must use the same domain as the mail server specified for Mail Address. Address for all warnings & critical messages. Enter the e-mail address to which alerts should be sent (for example, the e-mail address for the network administrator). Address for critical messages only. To instruct the REO Appliance to notify Overland automatically whenever a critical message is presented, enter the following e-mail address: techsupport@overlandstorage.com Alert Frequency. Enter a value of 5 or higher to specify how often (in minutes) the REO Appliance should send messages. To send only one message per error, enter 0. 2 To verify that the messaging system is configured correctly, click Test. If the test e-mail message is not successfully sent and received, correct the applicable information, and repeat the test. 3 Click Apply. Configuring E-mail Alerts W 59 Overland Storage REO 9000 with ProtectionPAC Software Setting the Time and Date Information The REO Appliance is originally set to use the time that corresponds to the Pacific time zone. If you are setting up the REO Appliance in a different time zone, you need to update the time and date settings accordingly. This ensures that any communication that occurs (for example, if an e-mail is automatically generated) reflects the correct date and time. 1 In the right pane, scroll down below the E-mail Notification section to locate the Set Time section. 2 Select the applicable settings, and click Submit. 3 After you complete these configuration steps for the management system, proceed to the configuration steps outlined in Configuring the Systems Involved in the Backup Process on page 61. 60 X Configuring the Management System 5 CHAPTER Configuring the Systems Involved in the Backup Process The main steps involved in configuring the backup servers include: Step 1 Mapping the REO Appliance to a drive letter to simplify access to the console and other installation and management tools. Step 2 Installing software client drivers or storage adapters for iSCSI or FC access. Mapping a Network Drive to the REO Appliance (Windows Only) To access the components used for installation and configuration of the REO Appliance, you must map a network drive from the system to a folder located on the REO Appliance. 1 Make sure that the REO Appliance is still powered on and that the REO SoftKey is still inserted in a USB port. 2 Perform the steps previously outlined under Mapping a Network Drive to the REO Appliance (Windows Only) on page 39. 3 Repeat these steps for each system that will access storage on the REO Appliance. Establishing Communication If you are using iSCSI connectivity, iSCSI initiators are required to communicate with the iSCSI targets (REO Devices) on the REO Appliance. Each backup server that uses the REO Appliance must be equipped with a software initiator, such as the Microsoft iSCSI Software Initiator, or an IP storage HBA, such as the Intel PRO/1000 T IP Storage Adapter. Note: You do not need TOE-equipped (Transmission Control Protocol [TCP] Offload Engine) or special iSCSI-capable GbE HBAs to work with software initiators. Any standard Network Interface Card (NIC) can serve as an iSCSI network interface device; however, Overland Storage strongly recommends that you use GbE for enhanced performance. If you are using FC connectivity, make sure that the applicable FC initiator is installed. Configuring the Systems Involved in the Backup Process W 61 Overland Storage REO 9000 with ProtectionPAC Software To establish communication 1 Install the desired software initiator or storage adapter. Note: For detailed information on various drivers and adapters, see the manufacturer’s documentation for assistance on assigning targets (REO Devices). You can also check the Overland Web site (www.overlandstorage.com) for the applicable Application Notes. 2 Repeat these steps for each system that will access storage on the REO Appliance. 3 After you complete these configuration steps, choose one of the following: If you want to use the default volume configuration of RAID 5 with logical volumes, proceed to the steps outlined in Creating Logical Volumes on page 71. If you want to use a different configuration, proceed to the steps outlined in Changing the Volume Configuration on page 63. 62 X Configuring the Systems Involved in the Backup Process 6 CHAPTER Changing the Volume Setup or Creating Logical Volumes The main steps involved in switching from one configuration to another or creating logical volumes include: Step 1 Selecting the applicable configuration. Step 2 Creating the desired number of logical volumes, and setting their size. Using the Default Volume Setup The REO Appliance uses a default volume configuration of RAID 5 with logical volumes. To use this configuration, you must create the logical volumes. X To use the default configuration and create logical volumes, proceed to Creating Logical Volumes on page 71. Changing the Volume Configuration You can use the Volume Setup feature in the console to select a different RAID configuration or to select the JBOD configuration. Important: Be aware that the process of changing the volume configuration takes time for the RAID 5 configurations while the arrays are initialized. After you select the new configuration and the initialization process begins, you can use the REO Appliance, but performance will be impacted. Overland Storage strongly recommends that you wait until the Status on the Physical Volume Management page is OK (not INITIALIZING) before using a volume. (Switching to a RAID 0 or JBOD configuration usually requires less than 10 minutes.) Changing the Volume Setup or Creating Logical Volumes W 63 Overland Storage REO 9000 with ProtectionPAC Software Selecting JBOD 1 In the left pane, under Volume Menu, click Volume Setup. Click Volume Setup. 2 In the Select Physical Configuration list, select JBOD only, and click Submit. 64 X Changing the Volume Setup or Creating Logical Volumes Setup Guide 3 When the warning message appears that indicates all data currently residing on the REO Appliance will be deleted, click OK to continue. 4 When the message appears that indicates the REO Appliance must be restarted, click OK to continue. 5 After waiting approximately five minutes, log on to the console, and then proceed to the steps outlined in Configuring REO Devices as Disk or Tape Devices on page 73. Selecting a RAID Configuration The REO Appliance supports RAID 0 and RAID 5. You can only select one configuration; that is you cannot set up one volume to use RAID 0 and set up another to use RAID 5. Important: Because the process of changing the volume configuration takes time if you select a RAID 5 option, Overland Storage recommends that you make your selection and let the process run overnight. (Switching to a RAID 0 or JBOD configuration usually requires less than 10 minutes.) In a RAID configuration, how the volumes are arranged depends on whether you are using an appliance that contains 12 physical disks or 24, and it depends on whether those disks are 250 GB or 400 GB in size. The appliance also contains two physical hosts (controllers). If you are using 12 physical disks, they are all assigned to the first host; if you are using 24 disks, the second set of disks is assigned to the second host. If you select a RAID 5 option, you will also have the option of creating a hot-spare disk drive for each physical host (controller) after you click Submit. (These disk drives remain in standby mode, so that you can use them immediately if another disk fails.) Changing the Volume Configuration W 65 Overland Storage REO 9000 with ProtectionPAC Software The following describes how the volumes are arranged in RAID configurations, depending on the number of disks and their size. If you are using the 12-disk appliance: RAID 0. Creates three REO Devices. Each REO Device (physical unit [PU]) is comprised of four disks. Each device provides either 1000 GB (using 250 GB disks) or 1600 GB (using 400 GB disks) of capacity. RAID 5, without hot spare. Creates two REO Devices. Each REO Device (PU) is comprised of six disks. Each device provides either 1250 GB (using 250 GB disks) or 2000 GB (using 400 GB disks) of capacity. RAID 5, with hot spare. Creates two REO Devices and one hot-spare disk. One REO Device (PU) is comprised of six disks and the other is comprised of five disks. The five-disk device provides either 1000 GB (using 250 GB disks) or 1600 GB (using 400 GB disks) of capacity, and the six-disk device provides either 1250 GB (using 250 GB disks) or 2000 GB (using 400 GB disks) of capacity. If you are using the 24-disk appliance: RAID 0. Creates six REO Devices (three physical units for each host). Each REO Device (PU) is comprised of four disks. Each device provides either 1000 GB (using 250 GB disks) or 1600 GB (using 400 GB disks) of capacity. RAID 5, without hot spare. Creates four REO Devices (two physical units for each host). Each REO Device (PU) is comprised of six disks. Each device provides either 1250 GB (using 250 GB disks) or 2000 GB (using 400 GB disks) of capacity. RAID 5, with hot spare. Creates four REO Devices (two physical units for each host) and one hot-spare disk for each host. One REO Device (PU) for each host is comprised of six disks and the other device for each host is comprised of five disks. The five-disk device provides either 1000 GB (using 250 GB disks) or 1600 GB (using 400 GB disks) of capacity, and the six-disk device provides either 1250 GB (using 250 GB disks) or 2000 GB (using 400 GB disks) of capacity. 66 X Changing the Volume Setup or Creating Logical Volumes Setup Guide To change the RAID configuration 1 In the left pane, under Volume Menu, click Volume Setup. Click Volume Setup. 2 In the list of volume configurations on the right, select the desired RAID configuration, and then click Submit. Select an option, and then click Submit. Changing the Volume Configuration W 67 Overland Storage REO 9000 with ProtectionPAC Software 3 If you selected a RAID 5 option and you want to create a hot spare for each host (controller), click OK when the following message appears; otherwise, click Cancel. Clicking Cancel does not prevent you from continuing with setting up a RAID 5 configuration; it instructs the appliance to skip the step of creating a hot spare. 4 When the warning message appears that indicates all data currently residing on the REO Appliance will be deleted, click OK to continue. 5 When the message appears that indicates the REO Appliance must be restarted, click OK to continue. 6 After waiting approximately five minutes, log on to the console. 68 X Changing the Volume Setup or Creating Logical Volumes Setup Guide 7 To view the volumes created for the configuration and their status, under Volume Menu in the left pane, click Physical Volume Management. Click Physical Volume Management. When you first create a new RAID 5 configuration, the Status for each physical unit (PU) is INITIALIZING. After the initial build phase completes (this can take a while, depending on the number of units and the size of each; to display the current percentage complete, click the Physical Volume Management option again), the Status changes to OK. While the volumes are in an initializing state, they are not redundant. Note: Although the volumes are available while they are in an initializing state, performance is impacted. Overland Storage strongly recommends that you wait until the Status is OK before using a volume. Changing the Volume Configuration W 69 Overland Storage REO 9000 with ProtectionPAC Software After the initial build completes, this status changes to OK. 70 X Changing the Volume Setup or Creating Logical Volumes Setup Guide 8 If you chose to create logical volumes, complete the steps outlined in the next section; otherwise, proceed to the steps outlined in Configuring REO Devices as Disk or Tape Devices on page 73. Creating Logical Volumes Using this feature, you can create up to 64 LUNs (volumes) of various sizes in 1 GB increments. 1 On the Logical Volume Management page, click Add Volume. 2 In the Volume Size box on the Create New Logical Volume page, enter the size (in GB) of the first volume that you want to create, and then click Add. Tip: If you intend to use the volume as a Dynamic Tape device, you can enter a 1. The information you enter later when you create the Dynamic Tape devices will override what you enter here. Enter the size of the first volume, and then click Add. The Logical Volume Management page reappears, with the new volume listed. After you have created a volume, you can also change its size (use the Expand button) or remove it from the list. 3 To create additional volumes, repeat step 1 and step 2. Creating Logical Volumes W 71 Overland Storage REO 9000 with ProtectionPAC Software Note: The maximum number of volumes you can create is 64, and the total amount of space you can use must be within the total amount of space available on the physical volumes (disk drives). 4 After you complete these steps, proceed to the steps outlined in Configuring REO Devices as Disk or Tape Devices on page 73. 72 X Changing the Volume Setup or Creating Logical Volumes 7 CHAPTER Configuring REO Devices as Disk or Tape Devices You can configure each REO Device to function either as a disk device (the default) or as a virtual LTO-2 tape device; that is, you can use each device in its native disk format, virtual-tape format, or any combination of the two. Note: To use the ShareDevice feature (available only on Windows) with a device, the device must be designated as a disk device. For more information, see Sharing Access to a REO 9000 Between Multiple Systems on page 115. As explained previously, the number of devices that you have depends on the volume configuration that you use. For example, if you use logical volumes with RAID 5, you can create up to 64 disk LUNs, 64 virtual LTO-2 tape devices, or any combination of LUNs and virtual LTO-2 devices up to 64 in total. Using Devices as Disk Devices X If you want each REO Device to function as a disk device (the default), proceed to the steps outlined in Associating Targets (Devices) and Initiators on page 87. Creating Tape Devices If you intend to create devices of type Tape or Dynamic Tape, note the following: As with standard tape devices, a specific driver (on a Windows system) or changes to a system configuration (on a UNIX system) might be required to operate with your selected backup software. For more information, check the Overland Storage Web site (www.overlandstorage.com) for Application Notes related to your specific backup software. If you are using logical volumes, you can create dynamic tape devices, which expand and contract to accommodate the size of a specific backup job. When you change the configuration of a device, all data currently residing on the device is deleted. Configuring REO Devices as Disk or Tape Devices W 73 Overland Storage REO 9000 with ProtectionPAC Software If you chose to use a RAID configuration with logical volumes (required if you want to create devices of type Dynamic Tape), you must create the volumes before you can change the device settings. For more information, see Creating Logical Volumes on page 71. If you choose to enable compression, be aware that various factors (such as the speed of your backup server, source devices, or network) can significantly affect performance. Additionally, the existing state of the files you are backing up (for example, whether the files are already compressed) can affect the level of compression that might be achieved. Consider these factors when you determine the applicable settings for your backup environment. Changing a Device from Disk to Tape (Standard) 1 In the left pane, under REO Device Menu, click REO Device Configuration. Click REO Device Configuration. The REO Device Configuration page displays the current settings for the first device listed in the REO Device ID list. 74 X Configuring REO Devices as Disk or Tape Devices Setup Guide 2 From the REO Device ID list, select the first device whose configuration you want to change. Select a device. 3 In the Device Type section, select Tape. 4 If you want to maximize backup storage capacity, select the Enable Tape Compression check box (for optimal backup performance, leave the check box cleared). 5 To change the default target name of a device, in the iSCSI Target Name box, type the new name (for example, LTO7). Important: The target names must be unique within a network. If you are using multiple appliances, you must change the default target names. For more information, see Expanding Storage Capacity (Scalability) on page 107. Type a new name (if desired), and then click Submit. 6 To save your changes, click Submit (or click Reset to cancel). Creating Tape Devices W 75 Overland Storage REO 9000 with ProtectionPAC Software 7 When the warning message appears that indicates all data currently residing on the device will be deleted, click OK to continue. Any changes you make are also reflected on the REO Device Summary page. Changes are reflected on the summary. 8 If you want to create dynamic tape devices, continue to the next section; otherwise, proceed to the steps outlined in Associating Targets (Devices) and Initiators on page 87. 76 X Configuring REO Devices as Disk or Tape Devices Setup Guide Changing a Device from Disk to Dynamic Tape 1 In the left pane, under REO Device Menu, click REO Device Configuration. Click REO Device Configuration. The REO Device Configuration page displays the current settings for the first device listed in the REO Device ID list. 2 From the REO Device ID list, select the first device whose configuration you want to change. Creating Tape Devices W 77 Overland Storage REO 9000 with ProtectionPAC Software The number of device IDs listed depends on the number of volumes that you created. Select a device. 3 In the Device Type section, select Dynamic Tape. Select Dynamic Tape. 4 If you want to maximize backup storage capacity, select the Enable Tape Compression check box (for optimal backup performance, leave the check box cleared). 5 If you want to specify a maximum size for the tape, enter the size in the Dynamic Tape Max Size box. The default is 0, which allows the appliance to use the available space on a volume, up to 2198 GB. Note: If you decide to change the maximum size at a later date, be aware that you can only increase the size; you cannot reduce it. To use a device with a smaller maximum size, you must either delete this device and re-create it using the desired size, or create an additional device that uses the desired size. 78 X Configuring REO Devices as Disk or Tape Devices Setup Guide 6 To change the default target name of a device, in the iSCSI Target Name box, type the new name (for example, LTO7). Important: The target names must be unique within a network. If you are using multiple appliances, you must change the default target names. For more information, see Expanding Storage Capacity (Scalability) on page 107. Type a new name (if desired), and then click Submit. 7 To save your changes, click Submit. 8 When the warning message appears that indicates all data currently residing on the device will be deleted, click OK to continue. Creating Tape Devices W 79 Overland Storage REO 9000 with ProtectionPAC Software After the change is processed, the REO Device Configuration page reappears and displays the serial number assigned to the device. You can use this serial number to identify the device in your backup software. This identifies the serial number assigned to the device. Any changes you make are also reflected on the REO Device Summary page. Changes are reflected on the summary. 9 After you complete these steps, proceed to the steps outlined in Associating Targets (Devices) and Initiators on page 87. 80 X Configuring REO Devices as Disk or Tape Devices 8 CHAPTER Configuring External (SCSI) Devices The SCSI ports on the REO Appliance let you attach external devices (such as tape drives or changers) and then use the console to assign initiators. The appliance provides two SCSI ports, and you can use a chain formation to assign up to 15 SCSI IDs to each port (the SCSI IDs must be unique within each port configuration). Important: For a list of supported SCSI devices (some device-types and configurations are not currently supported), see the REO Interoperability Matrix on the Overland Storage Web site at www.overlandstorage.com. Detecting External Devices When you enable power to the REO Appliance, it automatically detects whether External Devices are attached to the SCSI ports and displays the applicable information in the External Device Summary and External Device Configuration pages. If you turn off or detach an External Device while the REO Appliance is running, the External Device remains in the list of REO Device IDs, but the Device Type and SCSI Port:ID are set to None and the Inquiry Configuring External (SCSI) Devices W 81 Overland Storage REO 9000 with ProtectionPAC Software Information is set to No Device Found. (The items remain in the External Device Summary and the External Initiator Summary, even if you power down and restart the REO Appliance.) If you attach an External Device while the REO Appliance is running, use the Rescan feature to instruct the REO Appliance to detect the device and display the applicable information in the summary. 82 X Configuring External (SCSI) Devices Setup Guide To update the list of External Devices 1 In the left pane, under External Device Menu, click Rescan for External Devices. Click Rescan for External Devices. 2 When the following message appears, click Rescan to continue. Detecting External Devices W 83 Overland Storage REO 9000 with ProtectionPAC Software Changing the iSCSI Target Name Important: The target names must be unique with a network. If you are using multiple appliances, you must change the default target names. For more information, see Expanding Storage Capacity (Scalability) on page 107. 1 In the left pane, under External Device Menu, click External Device Configuration. Click External Device Configuration. The External Device Configuration page displays the current settings for the first External Device listed in the REO Device ID list. 2 From the REO Device ID list, select the first device whose configuration you want to change. The number of device IDs listed depends on the number of devices attached via the SCSI ports. Up to 30 device IDs (15 for each port) might be listed on this page. 84 X Configuring External (SCSI) Devices Setup Guide 3 To change the default target name of a device, in the iSCSI Target Name box, type the new name (for example, LTO2drive). Type a new name (if desired), and then click Submit. 4 To save your changes, click Submit (or click Reset to cancel). Any changes you make are also reflected on the External Device Summary page. Changes are reflected on the summary. 5 After you complete these steps, proceed to the steps outlined in Associating Targets (Devices) and Initiators on page 87. Changing the iSCSI Target Name W 85 Overland Storage REO 9000 with ProtectionPAC Software 86 X Configuring External (SCSI) Devices 9 CHAPTER Associating Targets (Devices) and Initiators The main steps involved in associating targets (REO Devices) and initiators with each other include: Step 1 Understanding how the targets and initiators must be identified so that they can successfully communicate with each other. Step 2 Making sure that IP addresses and names match on both the targets and the initiators. Step 3 Making another backup copy of the REO SoftKey so that your configuration information is preserved. Understanding How Initiators and Targets (Devices) are Connected To configure the REO Appliance as a backup-and-recovery-acceleration appliance, you must provide target and initiator information. Each volume on the REO Appliance is a target (REO Device); the servers are initiators. If you are using iSCSI initiators, an iSCSI name is required both at the targets and at the initiators. An iSCSI target name is required because it uniquely identifies a target as a storage resource for the initiators. An iSCSI initiator name is required because it helps identify an initiator for the purpose of target resource allocation (that is, which initiator has access to which target resource). If you are using FC initiators, you must provide a WWNN and WWPN for the same purpose of providing a unique identifier. Reviewing iSCSI Naming Conventions iSCSI names must be unique within the domain of the end user. However, because user domains can potentially merge with other user domains, the iSCSI naming mechanism is structured to ensure worldwide uniqueness. To ensure both domain and worldwide name uniqueness, iSCSI provides for the use of different types of naming mechanisms, based on the naming authority. Each iSCSI name is prefixed with a short designator string that indicates the type of naming Associating Targets (Devices) and Initiators W 87 Overland Storage REO 9000 with ProtectionPAC Software authority. The iqn prefix is used for iSCSI-qualified names and the eui prefix is used for Institute of Electrical and Electronics Engineers (IEEE) iSCSI names. To ensure the free movement of network HBAs between hosts without carrying over the SCSI state information, iSCSI initiator names are associated with iSCSI nodes instead of with network adapter cards. A target name should not be tied to hardware interfaces, which can be changed. A target name should identify the logical target and must be the same for the target, regardless of the physical portion being addressed. iSCSI-Qualified Names iSCSI-qualified names are constructed in four parts, each separated by a decimal. The first part of the name is the iqn prefix. The second part of the name is a date code in yyyy-mm format. The third part is a reversed domain name, and the fourth part is any string (within the character set and length boundaries) that uniquely identifies the initiator or target. For example, the iSCSI-qualified name iqn.200207.com.mycompany.storage:drive1 can be broken down into four parts as shown. Type Date iqn Organization Naming Authority Subgroup Naming Authority 2002-07 com.mycompany storage:drive1 Note: To enhance ease-of-use, the REO Appliance uses more simplified iSCSI target names. IEEE iSCSI Names IEEE iSCSI names are used when a manufacturer is already basing unique identifiers on worldwide names, as defined in the SCSI SPC-2 specification (ANSI [American National Standards for Information Systems], 2001. NCITS.351:2001. SCSI Primary Commands - 2 [SPC-2].). IEEE iSCSI names are constructed in two parts, separated by a decimal. The first part of the name is the eui prefix. The second part of the name is an EUI-64 address in ASCII hexadecimal (16 digits). For example, the IEEE iSCSI name eui.02004567A425678D can be broken down into two parts as shown. Type EUI-64 Worldwide Name eui 02004567A425678D 88 X Associating Targets (Devices) and Initiators Setup Guide Reviewing How Targets (REO Devices) and Initiators are Associated After you have named the targets and initiators (described later in this chapter), you must assign them to each other in pairs. This must be performed both on the REO Appliance by using the REO Appliance software console and on the application or backup server by using the iSCSI initiator management tools. The following illustrations demonstrate how this should be accomplished in an iSCSI configuration using the Microsoft iSCSI initiator. 1 Match the Data Port IP address on the REO Appliance to the target address on the backup server. For example, if Data Port 1 on the REO Appliance is assigned an IP address of 10.10.50.42, the IP address on the REO Appliance Network Configuration page must match the target address on the iSCSI configuration tool screens (you must launch the iSCSI configuration tool to obtain this information) for the backup server you are configuring. (To access the Add Target Portal dialog box, click Add on the Target Portals tab in the iSCSI Initiator Properties dialog box.) (To access this dialog box, double-click the Microsoft iSCSI Initiator icon on your desktop.) Note: The preceding example illustrates using the Microsoft iSCSI Configuration Tool. Understanding How Initiators and Targets (Devices) are Connected W 89 Overland Storage REO 9000 with ProtectionPAC Software 2 Verify that the iSCSI Target Name on the REO Appliance matches the target name on the backup server. For example, if one of the volumes on the REO Appliance is named idevice.name0, this is the iSCSI Target Name. The target name on the REO Appliance Device Configuration page must match the target name on the iSCSI configuration tool screens for the backup server you are configuring. Important: The target names must be unique within a network. If you are using multiple appliances, you must change the default target names. For more information, see Expanding Storage Capacity (Scalability) on page 107. 90 X Associating Targets (Devices) and Initiators Setup Guide 3 Match the iSCSI initiator name on the REO Appliance to the initiator name on the backup server. For example, if one of the volumes on the REO Appliance is named idevice.name0, this is the iSCSI Target Name. You must assign at least one initiator to this target (if you do not, you will not be able to access the disk). The iSCSI initiator name on the initiator portion of the REO Appliance Device Configuration page must match the initiator name on the iSCSI configuration tool screen for the backup server you are configuring. The Initiator IP Address field is optional. If used, both the iSCSI initiator name and the IP address will be checked by the REO Appliance and must match for access to be granted. Configuring Targets (REO Devices and External Devices) and Initiators Each disk or LUN on the REO Appliance is an iSCSI or FC target and has a passive role in fulfilling requests initiated by the application or backup server. The backup server is an initiator and plays the active role in issuing commands. An initiator is configured in conjunction with targets on the REO Appliance as an access control mechanism. You must configure an initiator by using the initiator software and by using the REO Appliance console. You can assign up to eight initiators (iSCSI, FC, or a combination of both) to each REO disk device (a virtual tape device currently supports only one initiator) or External Device. Configuring Targets (REO Devices and External Devices) and Initiators W 91 Overland Storage REO 9000 with ProtectionPAC Software Configuring REO Devices (Targets) and Initiators 1 In the left pane, under REO Device Menu, click REO Device Configuration. Click REO Device Configuration. The iSCSI Target Name fields are assigned default values of idevice.name0 through idevice.name23 (JBOD); idevice.name0, idevice.name1, idevice.name12, and idevice.name13 (RAID 0 or 5, without logical volumes); or idevice.name0 up through idevice.name63 (RAID 0 or 5, with up to 64 logical volumes). Important: The target names must be unique within a network. If you are using multiple appliances, you must change the default target names. For more information, see Expanding Storage Capacity (Scalability) on page 107. 92 X Associating Targets (Devices) and Initiators Setup Guide 2 To change an iSCSI Target Name, type the new name in the text box, and then click Submit. To change a target’s name, type the new name in this box, and then click Submit. 3 From the REO Device ID list, select the device for which you want to add initiators, and then click Add New Initiators. Select the device, and then click Add New Initiators. 4 If you are working with iSCSI, do the following: a In the Connection Type section, make sure that iSCSI is selected (this is the default). b In the iSCSI Initiator Name box, enter a unique name (up to 223 alphabetical or numerical characters) of an authorized initiator for the target. The fully qualified iSCSI name is assigned by the manufacturer of either the software initiator or the storage adapter installed on your backup server. Configuring Targets (REO Devices and External Devices) and Initiators W 93 Overland Storage REO 9000 with ProtectionPAC Software The iSCSI initiator name entered here must match the name of the iSCSI initiator on the associated backup server. Tip: To copy the initiator name if you are using the Microsoft initiator driver and then paste it here, use the initiator configuration tool. Click the Initial Settings tab, highlight the initiator node name, click Edit, and copy the initiator node name. Enter the unique name of the initiator, select the ID, and click Submit. c (Optional) In the Initiator IP Address box, if you want to use an additional level of authentication, use dotted decimal notation to enter the IP address of the backup server. If present, the IP address of the initiator is compared with the IP address you enter here. 5 If you are working with Fibre Channel, do the following: a In the Connection Type section, select FC. b In the WWNN and WWPN boxes, enter the official node and port names of the authorized initiator for the target. Tip: You can retrieve the initiator WWNN and WWPN by using the specific FC host adapter management software utility or by querying the name server on the FC switch. Select FC, enter the node and port names for the initiator, select the ID, and click Submit. 94 X Associating Targets (Devices) and Initiators Setup Guide 6 From the REO Device ID list, select the ID for the target to which you are assigning this initiator. 7 Click Submit. 8 Repeat step 3 through step 7 for each target. Configuring the iSCSI Initiator with Target (REO Device) and Initiator Assignments X On each applicable server, use the management tool that came with your iSCSI initiator to specify the target (REO Device) information. To configure the REO Appliance as a backup-and-recovery-acceleration appliance, you must provide target (REO Device) and initiator (host) information. An iSCSI name (for iSCSI) or a set of WWNN and WWPN names (for FC) is required for both the targets and the initiators. After targets and initiators have been specified, they must be assigned to each other. This must be performed on the server by using the software or hardware initiator, and on the REO Appliance by using the REO Appliance console, which you completed in the previous section. Note: For detailed information on various drivers and adapters, see the manufacturer’s documentation for assistance on assigning targets. You can also check the Overland Web site (www.overlandstorage.com) for the applicable Application Notes. Configuring Targets (REO Devices and External Devices) and Initiators W 95 Overland Storage REO 9000 with ProtectionPAC Software Configuring External Devices (Targets) and Initiators This process is similar to the steps outlined earlier for configuring REO devices. For detailed information, refer back to Configuring REO Devices (Targets) and Initiators. 1 In the left pane, under External Device Menu, click External Device Configuration. Click External Device Configuration. The iSCSI Target Name fields are assigned default values of idevice.name160 through idevice.name189. For details on changing a name, see Changing the iSCSI Target Name on page 84. 2 From the REO Device ID list, select the device for which you want to add initiators, and then click Add New Initiators. Select the device, and then click Add New Initiators. 96 X Associating Targets (Devices) and Initiators Setup Guide 3 In the iSCSI Initiator Name box, enter a unique name (up to 223 alphabetical or numerical characters) of an authorized initiator for the target. Enter the unique name of the initiator, select the ID, and click Submit. 4 (Optional) In the Initiator IP Address box, if you want to use an additional level of authentication, use dotted decimal notation to enter the IP address of the backup server. If present, the IP address of the initiator is compared with the IP address you enter here. 5 From the REO Device ID list, select the ID for the target to which you are assigning this initiator. 6 Click Submit. 7 Repeat step 2 through step 6 for each target. Configuring the iSCSI Initiator with Target (External Device) and Initiator Assignments X On each applicable server, use the management tool that came with your iSCSI initiator to specify the target (External Device) information. Backing Up Your REO SoftKey (Post-Configuration) Make another backup copy of all the files on the REO SoftKey. 1 Transfer the REO SoftKey to a USB port on a Windows 2000, 2003, or XP system that contains active virus-protection software. 2 If you are using Windows, double-click My Computer on your desktop (or use Windows Explorer), and browse to the software-key disk drive. The name of this disk varies based on your system configuration, but it will be called something like Removable Disk (G:). 3 Make a backup copy of all the data on the REO SoftKey, and store the copy in a secure location. Backing Up Your REO SoftKey (Post-Configuration) W 97 Overland Storage REO 9000 with ProtectionPAC Software 98 X Associating Targets (Devices) and Initiators 10 Working with the REO 9000 CHAPTER This chapter provides a few tips on working with the REO Appliance including: Logging on to the Web interface. Reviewing the information displayed in the REO Device Summary. Switching from one configuration to another. Understanding how disk drives are numbered. Powering down the REO Appliance. Logging On from Any System with Network Access After you have completed configuration of the REO Appliance, you can access the REO Appliance console from any system that has network access to the IP address of the Management Port. 1 Choose one of the following: If you are using DHCP, using the management system, access the mapped drive \\REO\programs, and then double-click the Overland.html file. If you are not using DHCP, in your Web browser, type the IP address assigned to the Management Port for the REO Appliance. Tip: You can also use the IP addresses assigned to the Data Ports, which you can do even if you are using DHCP. 2 When the prompt appears, type your name and password (the defaults are Administrator and system) in case-sensitive format. Working with the REO 9000 W 99 Overland Storage REO 9000 with ProtectionPAC Software The REO Appliance console appears. Note: If multiple users log on to the console at the same time, the console saves the last update received. Understanding the Summary Pages The ProtectionPAC software includes a summary page that lists the REO Devices and another that lists the initiators. If you are using external devices, there are also corresponding summary pages for those devices and initiators. 100 X Working with the REO 9000 Setup Guide Reviewing the REO Device Summary Page The REO Device Summary page provides an immediate view of your REO Appliance and its status. The following shows two examples of what you might see on this page (what you see depends on how you configure your REO Appliance). This image shows the JBOD configuration on an FCenabled appliance. Three of the REO Devices have been configured to function as virtual LTO-2 tape devices. This image shows the RAID 5 configuration, with logical volumes, on an FC-enabled appliance. The connections have all been changed to operate through FC. Five logical volumes have been created at this point. The following explains each of the columns: REO Device ID. This entry is automatically designated by the REO Appliance. Depending on the configuration, you might have up to 64 IDs in this list. iSCSI Target Name. Displays either the default name assigned by the REO Appliance or the new name assigned by you. FC LUN. If you purchased the FC-enabled appliance, this column displays the LUN for each device. Understanding the Summary Pages W 101 Overland Storage REO 9000 with ProtectionPAC Software Status. Indicates whether the device is Up or Down. In addition to using an Up or Down label, the color green indicates that the item is okay, orange indicates that the item is in an unprotected state (for example, initializing), and red indicates that the item is unavailable (for example, a disk is missing). Note: This status is different from that which is shown on the Physical Volume Management page. For example, if you switch from a JBOD configuration to a RAID 5 configuration, the status of the two device IDs on the summary page will be Up, while the status for the two volumes on the Physical Volume Management Page will be INITIALIZING. Device Type. Indicates whether the device is exported as a disk drive or as a virtual LTO-2 tape drive. If you create a Tape Device or Dynamic Tape Device and select the Enable Tape Compression check box, Tape (or Dynamic Tape) appears in italic formatting in this column. If you use the ShareDevice feature, Disk appears in italic formatting. Size (GB). Indicates the amount of space allocated to the device. Tip: To access the REO Device Configuration page for a specific device, click the applicable REO Device ID. Reviewing the Initiator Summary Page The Initiator Summary page provides an immediate view of the initiators (systems) that you have defined for the REO Devices. For each initiator, this page shows information such as which devices (targets) it is associated with and the type of connection. The following image shows the initiators for a RAID configuration using logical volumes on an FC-enabled appliance. Tip: To access the Initiator Configuration page for a specific initiator, click the applicable Initiator Name. To access the REO Device Configuration page for a specific device, click the applicable REO Device ID. 102 X Working with the REO 9000 Setup Guide Reviewing the External Device Summary The External Device Summary page provides an immediate view of the External Devices attached to the REO Appliance. The following explains each of the columns: REO Device ID. This entry is automatically designated by the REO Appliance. Depending on the configuration, you might have up to 30 IDs in this list. iSCSI Target Name. Displays either the default name assigned by the appliance or the new name assigned by you. Device Type. Indicates whether the device is exported as a Changer (medium changer), Tape (tape drive), or CD/DVD (CD-ROM or DVD drive). SCSI Port:ID. Identifies the SCSI port through which the device is attached and the SCSI ID of the device itself. Inquiry Information. Displays information published by the device itself (for example, the type of drive technology that the device uses). Reviewing the External Initiator Summary Page The External Initiator Summary page provides an immediate view of the initiators (systems) that you have defined for the External Devices (targets). For each initiator, this page shows which devices (targets) it is associated with and any information known about those devices. Tip: To access the External Initiator Configuration page for a specific initiator, click the applicable Initiator Name. To access the External Device Configuration page for a specific device, click the applicable REO Device ID. Understanding the Summary Pages W 103 Overland Storage REO 9000 with ProtectionPAC Software Reviewing How the Disk Drives are Numbered Numbering begins with the disk in the upper-left corner (disk 0) and moves from left to right. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Understanding What the LEDs Represent The front of the appliance includes several LED lights. If an LED for a port (network connection) is blinking, it indicates that the port is in use. The LED that represents power indicates whether power is enabled. Each disk drive also presents two LEDs: one for power and one for activity. LEDs for Mgmt. Port, Data Port 1, and Data Port 2 LEDs for temperature and fans LED for power Appliance LED for power to disk Hard disk 104 X Working with the REO 9000 LED for activity on disk Setup Guide Powering Down the REO Appliance To ensure preservation of data on the REO Appliance, do not turn off the appliance using the power button on the REO Appliance. You must verify that none of the initiators have active connections, and you should use the Shutdown/Restart option in the software console to power down the REO Appliance. 1 Make sure that none of the initiators (servers) have active connections with the REO Appliance. For example, in the iSCSI Initiator Properties dialog box for the Microsoft initiator, you can check the Active Sessions tab to determine if there is a connection that needs to be terminated. Powering Down the REO Appliance W 105 Overland Storage REO 9000 with ProtectionPAC Software 2 In the software console, under System Menu, click Maintenance. Click Maintenance. 3 In the System Maintenance page, under Shut Down/Restart, click the applicable button. If you want to shut down the REO Appliance briefly and then automatically restart it, click Restart. When the confirmation message appears, click OK to continue. Wait several minutes before you log back on to the console. If you want to shut down the REO Appliance and leave the power off, click Shut Down. When the confirmation message appears, click OK to continue. Wait several minutes before you perform any maintenance on the REO Appliance. 106 X Working with the REO 9000 11 CHAPTER Expanding Storage Capacity (Scalability) This chapter explains how to add one or more additional REO Appliance appliances to expand the storage capacity in an iSCSI or FC environment. If you are using the 12-disk version of the REO 9000 and you subsequently purchased the additional 12-disk upgrade kit, it also describes how to add the additional disks to the appliance. Important: If you purchased multiple units, set up (attach and configure) one unit at a time. The target names must be unique within a network; that is, if you are using multiple appliances, you must change the default target names. Setting Up Additional REO Appliances in an iSCSI Configuration 1 Install, configure, and manage each REO Appliance that you purchased using the same instructions provided for the REO Appliance that it complements. Using this method, you will have multiple, independent management consoles. 2 Enable power to the first appliance and complete the configuration process before enabling power to the next appliance, and so on. Expanding Storage Capacity (Scalability) W 107 Overland Storage REO 9000 with ProtectionPAC Software Important: Because each appliance (the primary REO Appliance and each associated REO Appliance) has its own console, change the default values for the iSCSI Target Name fields on the REO Device Configuration page, and change the REO Name and REO Description fields (the default is REO) under System Information on the System Configuration page so that all names are unique. Change every iSCSI Target Name, REO Name, and REO Description to use a unique name. Setting Up Additional REO Appliances in an FC Topology There are two options for adding additional REO Appliances to your FC environment. You can attach each REO Appliance to its own set of ports on an FC switch in a fabric or point-to-point topology. For a loop topology, attach each REO Appliance to its own set of ports on an FC hub. 108 X Expanding Storage Capacity (Scalability) Setup Guide The Fibre Channel ports on the back of the REO Appliance are numbered port 0 (bottom) and port 1 (top). Port 1 Port 0 Setting Up Additional REO Appliances in an FC Topology W 109 Overland Storage REO 9000 with ProtectionPAC Software Attaching Each REO Appliance Separately 1 Attach each REO Appliance in the set to a separate set of ports on the FC switch or hub. FC switch or hub FC switch or hub 110 X Expanding Storage Capacity (Scalability) Setup Guide 2 Configure and manage each REO Appliance using the same instructions provided for the REO Appliance that it complements. Important: Because each appliance (the primary REO Appliance and each associated REO Appliance) has its own console, change the default values for the iSCSI Target Name fields on the REO Device Configuration page, and change the REO Name and REO Description fields under System Information on the System Configuration page so that all names are unique. Also change the FC-specific information on the Network Configuration page for each additional REO Appliance. Change every iSCSI Target Name, REO Name, and REO Description to use a unique name. Setting Up Additional REO Appliances in an FC Topology W 111 Overland Storage REO 9000 with ProtectionPAC Software Expanding the Capacity of a REO 9000 by Adding Disk Drives If you initially purchased a REO 9000 with 12 disks and subsequently purchased the upgrade for an additional 12 disks, complete the following steps to install the additional disks. Important: Overland Storage recommends that this part be installed by an authorized IT service person or an Overland Storage-authorized service provider. Improper installation may result in damage to this part or the appliance which will void the current warranty. 1 Make sure that the none of the initiators (servers) have active connections with the appliance. 2 Open the face-plate to expose the individual disk-drive slots. 3 Remove the first empty disk carrier (disk 12) by pressing the button on the front of the carrier and using the lever to pull the carrier out of the slot. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 4 If the new disk carrier (which contains a disk) is not labeled with a slot number, use a blank label from the accessory kit to label the new carrier as disk 12. 5 Insert the new disk carrier (disk 12) into the applicable slot on the appliance, and close the disk carrier by making sure that the lever is in its fully extended, open position; pressing the right side of the carrier into the slot; and then pressing the lever in. Pressing the lever in draws the carrier fully into the slot and locks it in place. 6 Repeat step 4 and step 5 for each new disk carrier, labeling them in order, until all 12 additional disk drives are seat in the appliance. 7 Close the face-plate. 112 X Expanding Storage Capacity (Scalability) Setup Guide 8 In the left pane, under Volume Menu, click Physical Volume Management. Click Physical Volume Management. 9 Perform the applicable steps for the volume configuration that you are using: If you are using a JBOD configuration, the 12 new disks are listed in the FREE DRIVE POOL. Click the Add button for the first new disk, and then click OK when the confirmation message appears. Repeat this step for each new disk. If you are using a RAID 0 configuration, the new disks are listed in the FREE DRIVE POOL for the second host. Click the Create button that appears next to the list of new disks, and then click OK when the confirmation message appears. Repeat these steps until there are no disks remaining in the FREE DRIVE POOL and a Create button is no longer available. (For more information, see Selecting a RAID Configuration on page 65.) If you are using a RAID 5 configuration, the new disks are listed in the FREE DRIVE POOL for the second host. Click the Create button that appears next to the list of new disks, click OK if you want to create a hot spare, and then click OK when the confirmation message appears. Repeat these steps until there are no disks remaining in the FREE DRIVE POOL and a Create button is no longer available. (For more information, see Selecting a RAID Configuration on page 65.) Expanding the Capacity of a REO 9000 by Adding Disk Drives W 113 Overland Storage REO 9000 with ProtectionPAC Software 10 If you are using a RAID configuration with logical volumes, use the Logical Volume Management page to expand the size of the existing volumes or create additional volumes. For more information on creating logical volumes, see Creating Logical Volumes on page 71. 114 X Expanding Storage Capacity (Scalability) A APPENDIX Sharing Access to a REO 9000 Between Multiple Systems The ShareDevice feature lets you share a single disk (physical or virtual) with more than one initiator. You can use this feature with any combination of iSCSI or FC initiator connections. However, only one initiator can access a single disk (physical or virtual) at a time. Note: The ShareDevice feature is currently only available on Windowsbased operating systems and is not supported for tape emulation. It also requires that the size of the device being shared is 400 GB or smaller. For Windows-based initiators, the product includes a set of scripts that helps you automate the process of sharing the disks. Ovlndstart.exe. You can insert this file into the pre-processing script of the backup application to suspend operation of the backup job until the REO Appliance is ready (not in use by another server). If your preprocessing utilizes a script or batch file, make ovlndstart.exe the first executable line in the file. Ovlndstop.exe. You can insert this file into the post-processing script of the backup application to flush all data from cache and then relinquish control of the REO Appliance. If your post-processing utilizes a script or batch file, make ovlndstop.exe the first executable line in the file. Important: If you do not use the scripts, you might experience errors (for example, “Disk not ready” or “Backup device not ready”) when an initiator attempts to access a disk that is currently being controlled by another initiator. Sharing Access to a REO 9000 Between Multiple Systems W 115 Overland Storage REO 9000 with ProtectionPAC Software Configuring Devices as Shared Devices Note the following additions to the steps outlined previously in Configuring REO Devices as Disk or Tape Devices. 1 Select the ShareDevice check box. 2 To access the folder that contains script files, which you can append to the default scripts for your backup software, do the following: a Access the mapped network drive \\REO\programs. b Open the scripts folder, and select the ovlndstart.exe and ovlndstop.exe files. Copy these files to each applicable server. 116 X Sharing Access to a REO 9000 Between Multiple Systems Setup Guide c Copy the files to the appropriate location (path) for your backup application (for example, C:\WINNT) folder on each server that will participate in the backup process. d Edit your the pre-processing script in the backup application to call ovlndstart.exe, and edit the post-processing script to call ovlndstop.exe. You can use these scripts with any backup software agent that can run pre- and post-process scripts, with batch files that launch backup or copy operations at a later time, or with scheduling tools such as Windows AT Scheduler or WinCron. Tip: For specific instructions related to some of the backup software products currently supported by the REO Appliance, see the applicable Application Notes on the Overland Storage Web site at: www.overlandstorage.com Accessing a Shared Device After you have completed configuration of the targets and initiators, the REO Appliance makes each REO Device (target) appear as a removable disk on your servers. The removable disk (REO Device) can be sequentially (but not simultaneously) accessed by multiple servers. If the removable disk is available (no activity for approximately five minutes), it can be accessed by either one of the initiators. X To expedite the process of making the removable disk available, rightclick its icon, and select Eject. Right-click, and select Eject. Accessing a Shared Device W 117 Overland Storage REO 9000 with ProtectionPAC Software 118 X Sharing Access to a REO 9000 Between Multiple Systems B Basic Troubleshooting APPENDIX As you troubleshoot the REO Appliance, keep the following guidelines in mind: Do not turn off the REO Appliance using the power button on the appliance. You must verify that none of the initiators have active connections, and you should use the Shutdown/Restart option in the software console to power down the REO Appliance. Never remove the chassis cover. If a peripheral does not work, make sure that all connections are secure. Using the SoftKey Reset Option Use this option, which is available via the System Maintenance page, only when you are instructed to do so by Overland Storage Technical Support. Important: If you click Reset, your network- and system-configuration settings will be returned to the factory defaults. Basic Troubleshooting W 119 Overland Storage REO 9000 with ProtectionPAC Software Sending the Log Files to Technical Support The REO Appliance creates and maintains log files that contain diagnostic information intended for use by Overland Storage Technical Support in troubleshooting issues you might encounter. The logs are updated every 60 seconds, with new information appended to the beginning of the applicable file. When the maximum log-file size is reached, previous information is deleted so that new information can be added. To locate the logs (if requested by Technical Support) 1 Access the mapped network drive \\REO\programs, and open the logs folder. Open the logs folder. Send copies of all files. 2 Use your e-mail application to forward copies of the files to: support@overlandstorage.com. Tip: If the files are significant in size, consider using an application such as WinZip to compress the logs folder and send the compressed version of the folder instead. Unable to Access the REO Appliance If you cannot access the REO Appliance through the console or through the Data Ports, try the following: 1 Check the LED lights on the REO Appliance. If lights are not on, check all connections between the REO Appliance and the power source. 2 Make sure that all applicable IP addresses are correct. 3 Make sure the network cables are properly installed. The network cables must be securely attached at all connections. If the cables appear to be properly attached but the problem persists, try different cables. 120 X Basic Troubleshooting Setup Guide REO Appliance Does Not Start If DHCP is not operational on your LAN, you must manually edit the configuration file on the REO SoftKey before you connect it to the REO Appliance and start it. If you already edited the configuration file or if your LAN uses DHCP and the REO Appliance is beeping repeatedly, it might be because a LAN cable is not connected to the Management Port, the REO SoftKey is not inserted, the key is not inserted correctly, the key is damaged, the copy-protection file on the key is invalid, or the wrong key was used. To determine why the appliance does not start X Choose one of the following: If your LAN does not use DHCP and you have not edited the configuration file on the key, perform the steps outlined under Editing the Configuration File (for a non-DHCP or UNIX Management System) on page 33. If your LAN uses DHCP or if you already edited the configuration file, do the following: Use the software console to restart the REO Appliance. For more information, see Powering Down the REO Appliance on page 105. If you want a cable connected to the Management Port, make sure that you are using the applicable type of cable and that a DHCP server available (if the Management Port is configured for DHCP, it will not complete the startup process until a system with DHCP is located). Otherwise, disconnect the cable from the Management Port. Make sure that you are using the correct key (for example, if you purchased more than one unit, you might have mixed up the keys). Make sure that the key is functional by inserting it into a USB port on your management system and verifying that you can view the contents. If these steps do not solve the problem, contact Customer Support at Overland Storage. For contact information, see Customer Support on page 159. REO Appliance Does Not Start W 121 Overland Storage REO 9000 with ProtectionPAC Software Unable to Log On to the Console If you are unable to log on to the REO Appliance console, it might be because you are using Internet Explorer and the privacy setting is set above Medium (the console is a Web-enabled program that requires the use of cookies; setting the privacy option higher than Medium prevents the program from working correctly), it might be because you are entering the name and password incorrectly, or it might be because you are using the wrong REO SoftKey. 1 If you receive a message similar to the following, replace the key currently inserted in the appliance with the correct key. This message indicates that you have inserted a key that is using software version 2.2 or later into an appliance that is currently configured to use software version 2.1 or earlier. For instructions on upgrading the appliance, see the applicable release notes posted on the Web site at www.overlandstorage.com. 2 Make sure that you are entering the name and password correctly; they are case-sensitive. The console uses the following defaults for the name and password: Name: Administrator Password: system 3 If you changed the default name or password and subsequently forget the new information, perform the steps outlined under I Forgot the New Password or Logon Name on page 128 to locate the required information. 4 If you are unable to access the console in Internet Explorer running on any version of Windows other than Windows Server 2003, do the following (if you are using Windows Server 2003, perform the steps outlined in the next section, Internet Explorer Does Not Redirect from IP Address on Windows Server 2003): a Launch Internet Explorer. b In the Tools menu, click Internet Options. c On the Privacy tab, move the slider to Medium (or lower). d To save your changes, click OK. 122 X Basic Troubleshooting Setup Guide Internet Explorer Does Not Redirect from IP Address on Windows Server 2003 If you access the REO Appliance console using Internet Explorer running on Windows Server 2003, you might see a blank screen after you enter a valid IP address for the REO Appliance to which you are trying to connect. This happens because Internet Explorer has an enhanced security configuration that is enabled by default in Windows Server 2003. This setting does not allow the server to redirect the IP address to the correct location. To prevent this from occurring, you need to add the IP address for the REO Appliance to the list of trusted sites for this server. To add the REO Appliance to the list of trusted sites 1 Launch Internet Explorer. 2 In the Tools menu, click Internet Options. 3 On the Security tab, select Trusted Sites, and then click Sites. Unable to Log On to the Console W 123 Overland Storage REO 9000 with ProtectionPAC Software 4 In the Add this Web site to the zone box, type the IP address for the REO Appliance, and click Add. 5 To dismiss the Trusted sites dialog box, click Close, and then click OK to save your changes and close the Internet Options dialog box. 6 In the browser window, try accessing the console for the REO Appliance again. The log on window should appear. Browser Does Not Reflect Changes Made from Another System or Browser Window If you have multiple browser windows open that are pointing to the same REO Appliance, changes that you make from one browser window will not display in another (second) browser window until you log out of the second window and log back on. This occurs whether the second browser window is open on the same system or on a different system. X To view updates, exit the browser, open the browser, and log back on. 124 X Basic Troubleshooting Setup Guide Unable to Connect to the Disks via Windows Explorer If you are unable to access the disks on the REO Appliance, it might be because the system or a disk on the appliance is malfunctioning, because the disks were reformatted using a file system other than NTFS, or because the disks are not formatted. 1 Make sure that the REO Appliance is turned on and that all cables are correctly connected. 2 Make sure that you can view other disks from the same initiator. If not, there might be a problem with a cable or the Ethernet connection. 3 Make sure that you can view the targets (REO Devices) from the initiator. a Log on to the software console. b In the left pane, under Volume Menu, click Physical Volume Management. Click Physical Volume Management. c Verify that the Status of each volume and disk is OK, which indicates that the target is functioning correctly. Unable to Connect to the Disks via Windows Explorer W 125 Overland Storage REO 9000 with ProtectionPAC Software d Check the ALARM MESSAGES section to see if there are any alerts regarding the disks. These messages (also known as asynchronous event notifications) display additional information about each disk that might not be displayed in an alert e-mail. Make sure that the Status of each volume and disk is OK. 126 X Basic Troubleshooting Setup Guide 4 If you are trying to view the disks from a Windows NT system, make sure that the disks are formatted as NTFS volumes. The disks are factory-formatted using NTFS 4. If you reformat the disks as another type of file system (such as FAT or FAT32), you will not be able to access the disks using Windows NT. If you are able to view the disks from Windows 2000 or 2003, but not from Windows NT, it indicates that the disks are not NTFS. Tip: To double-check the file-system property, on a Windows 2000 or 2003 system, right-click the disk, click Properties, and note the File system designation on the General tab. Perpetual Loop of Audio Alerts On startup, the REO Appliance might reach an error state and begin an endless loop of alerts. The pattern (2 beeps separated by a 1-second delay) repeats every 4 seconds. X If the REO Appliance reaches this error state, turn the REO Appliance off and then back on. The cause of this error state might also be one of the following: A LAN cable is not connected to the Management Port. The REO SoftKey is not inserted, is not inserted correctly, or is physically damaged. The wrong REO SoftKey was used (you inserted the wrong key). Disabling the Audio Alarm If a power supply or fan fails or detects an issue with the appliance, an audible alarm sounds. If you do not have the spare component needed to correct the situation (for example, if you need to replace a power supply), press the small, red button on the back of the appliance to turn off the sound temporarily (after you correct the situation, make sure that you press the button again to engage the audio feature). Systems Restart When I Map a Disk Drive If your systems restart whenever you try to map a disk, it indicates that your LAN does not use DHCP, and you did not manually edit the configuration file located on the REO SoftKey before continuing with the configuration process. X If your LAN does not use DHCP and you have not edited the configuration file on the key, perform the steps outlined under Editing the Configuration File (for a non-DHCP or UNIX Management System) on page 33. Perpetual Loop of Audio Alerts W 127 Overland Storage REO 9000 with ProtectionPAC Software I Forgot the New Password or Logon Name If you change the default name and password that you use to log on to the console and subsequently forget the new information, use the following steps to locate the required information. 1 Make sure that you are entering the name and password correctly; they are case-sensitive. The default name is Administrator, and the default password is system. 2 Using a text editor, open the login file located in the:\var\Overland folder on the REO SoftKey. Open the login file. 3 Search for the line with UserName and Password, and note the corresponding information. Note this information. Important: Do not use this file to modify the name or password information. 128 X Basic Troubleshooting Setup Guide Lost or Damaged REO SoftKey or Files Accidentally Deleted from the Key The REO SoftKey contains the software and settings required for configuring the REO Appliance that you purchased (note that if you purchased multiple units, the keys are not interchangeable). If you lose or damage this key, you cannot restart or reconfigure your REO Appliance. Important: If you purchased multiple units, note that the keys are not interchangeable. 1 Note the serial number of your REO Appliance, which is located on the exterior of the appliance. 2 Contact Customer Support at Overland Storage. For contact information, see Customer Support on page 159. Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance When there is a problem with a disk drive, its Status on the Physical Volume Management page is reported on as NOT PRESENT, and the disk moves to the FREE DRIVE POOL section (if you are using RAID 0, all associated disks in the applicable volume also move to the FREE DRIVE POOL section). The first step you can take is to force an addition of the disk (JBOD only), re-creation of the volume that contains the disk drive in question (RAID 0), rebuild of the volume that contains the disk drive in question (RAID 5 without hot spares), or re-creation of a hot spare (RAID 5 with hot spares). The next step is to replace the applicable disk with a spare disk. Forcing an Add (JBOD) 1 Make sure that none of the initiators (servers) have active connections with the REO Appliance. For example, in the iSCSI Initiator Properties dialog box for the Microsoft initiator, you can check the Active Sessions tab to determine if there is a connection that needs to be terminated. Lost or Damaged REO SoftKey or Files Accidentally Deleted from the Key W 129 Overland Storage REO 9000 with ProtectionPAC Software 2 Log on to the software console. 3 In the left pane, under Volume Menu, click Physical Volume Management. Click Physical Volume Management. 130 X Basic Troubleshooting Setup Guide 4 In the Physical Volume Management page, click the Add button next to the disk drive whose Status is NOT PRESENT. When a disk is unavailable, it appears in the FREE DRIVE POOL section of the page. For the disk whose Status is NOT PRESENT, click Add. 5 When the confirmation message appears, click OK. 6 Note whether the Status of the specific disk drive changes to OK. If the disk drive is recovered, the disk returns to its position in the list (that is, it no longer appears in the FREE DRIVE POOL section), the Status changes to OK, and you can resume normal operations with the REO Appliance. If the disk drive cannot be recovered, the following message appears. If this message appears, replace the applicable disk with a spare disk (for more information, see Purchasing a Spare Disk Drive on page 144). If the REO Appliance continues to report a problem after you replace the disk, contact Overland Storage Technical Support (for more information, see Customer Support on page 159). Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance W 131 Overland Storage REO 9000 with ProtectionPAC Software Re-Creating a RAID 0 Volume 1 Make sure that none of the initiators (servers) have active connections with the REO Appliance. For example, in the iSCSI Initiator Properties dialog box for the Microsoft initiator, you can check the Active Sessions tab to determine if there is a connection that needs to be terminated. 2 Log on to the software console. 132 X Basic Troubleshooting Setup Guide 3 In the left pane, under Volume Menu, click Physical Volume Management. Click Physical Volume Management. Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance W 133 Overland Storage REO 9000 with ProtectionPAC Software 4 In the Physical Volume Management page, click the Create button for the set of disks currently in the FREE DRIVE POOL section. Click Create. 5 When the confirmation message appears, click OK. 134 X Basic Troubleshooting Setup Guide The system tries to re-create the volume using the disks that are currently in the FREE DRIVE POOL section. The process will either succeed or fail. If the process succeeds, the volume is re-created. If the Status is OK, you can resume normal operations with the REO Appliance. If the process fails, an error message appears, and the disks remain in the FREE DRIVE POOL section. You must replace the applicable disk. For more information, see Purchasing a Spare Disk Drive. If the REO Appliance continues to report a problem after you replace the disk, contact Overland Storage Technical Support (for more information, see Customer Support on page 159). Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance W 135 Overland Storage REO 9000 with ProtectionPAC Software Rebuilding a Volume (RAID 5 Without Hot Spare) When an issue arises with a disk in a RAID 5 configuration, the disk in question moves to the FREE DRIVE POOL section and the volume has a Status of DEGRADED. The volume is placed in a degraded state. The disk with an issue moves here. To test the disk by forcing a rebuild 1 Make sure that none of the initiators (servers) have active connections with the REO Appliance. 136 X Basic Troubleshooting Setup Guide For example, in the iSCSI Initiator Properties dialog box for the Microsoft initiator, you can check the Active Sessions tab to determine if there is a connection that needs to be terminated. 2 Log on to the software console. 3 In the left pane, under Volume Menu, click Physical Volume Management. Click Physical Volume Management. Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance W 137 Overland Storage REO 9000 with ProtectionPAC Software 4 In the Physical Volume Management page, click the Rebuild button for the volume whose Status is DEGRADED. For the volume whose Status is DEGRADED, click Rebuild. 5 When the confirmation message appears, click OK. 138 X Basic Troubleshooting Setup Guide The system tries to use the disk that is currently in the FREE DRIVE POOL section to rebuild the volume. While in work, the Status of the volume is REBUILDING. The process will either succeed or fail. Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance W 139 Overland Storage REO 9000 with ProtectionPAC Software If the process succeeds, the disk returns to the volume, the Status is OK, and REMOVE buttons become available for the disks. If the Status is OK, you can resume normal operations with the REO Appliance. If you want to ensure the integrity of the volume and the redundancy of the data, click Verify. If the process fails, an error message appears, and the disk remains in the FREE DRIVE POOL section. You must replace the applicable disk. For more information, see Purchasing a Spare Disk Drive. If the REO Appliance continues to report a problem after you replace the disk, contact Overland Storage Technical Support (for more information, see Customer Support on page 159). 140 X Basic Troubleshooting Setup Guide Re-Creating a Hot Spare (RAID 5 With Hot Spares) When an issue arises with a disk in a RAID 5 configuration and you are using hot spares, the disk in question moves to the FREE DRIVE POOL section, and the system automatically begins a rebuild process by using the disk initially designated as a hot spare. The questionable disk remains in the FREE DRIVE POOL section and is assigned a Hot Spare button. To determine if the questionable disk needs to be replaced, you can use it to re-create a hot spare. If process fails, you must replace the disk. A rebuild begins with the hot spare replacing the questionable disk. This disk displays a Hot Spare button. To test the disk by creating a hot spare 1 Make sure that none of the initiators (servers) have active connections with the REO Appliance. Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance W 141 Overland Storage REO 9000 with ProtectionPAC Software For example, in the iSCSI Initiator Properties dialog box for the Microsoft initiator, you can check the Active Sessions tab to determine if there is a connection that needs to be terminated. 2 Log on to the software console. 3 In the left pane, under Volume Menu, click Physical Volume Management. Click Physical Volume Management. 142 X Basic Troubleshooting Setup Guide 4 In the Physical Volume Management page, click the Hot Spare button next to the disk in the FREE DRIVE POOL section. Click Hot Spare. 5 When the confirmation message appears, click OK. Determining Whether a Disk Drive is Faulty or There is a Problem with the REO Appliance W 143 Overland Storage REO 9000 with ProtectionPAC Software The process will either succeed or fail. If the process succeeds, the disk moves from the FREE DRIVE POOL section to the HOT SPARE section. If the process fails, an error message similar to the following appears. You must replace the applicable disk. For more information, see Purchasing a Spare Disk Drive. Purchasing a Spare Disk Drive 1 Note the serial number of your REO Appliance, which is located on the exterior of the appliance. 2 Contact your local reseller or contact Customer Support at Overland Storage. For contact information, see Customer Support on page 159. 144 X Basic Troubleshooting Setup Guide Does the Appliance Automatically Start After a Power Outage? If the facility in which your REO Appliance is installed experiences an interruption in power, the appliance will not automatically run through the power-up sequence when power is restored. You must manually start the appliance. Does the Appliance Automatically Start After a Power Outage? W 145 Overland Storage REO 9000 with ProtectionPAC Software 146 X Basic Troubleshooting C Updating the Appliance APPENDIX Updates for your product might be available via the Overland Storage Web site. The update might be for the software, for the different instances of firmware on the appliance, or for both. Overland Storage recommends that you note what version of the product you have installed and check the Web site to see if an update is available. Determining the Version of the Product 1 Log on to the software console. 2 In the left pane, under System Menu, click Maintenance. Click Maintenance. Updating the Appliance W 147 Overland Storage REO 9000 with ProtectionPAC Software 3 In the System Maintenance page, under REO Information, note what is listed for Product Version. Checking For and Downloading Updates 1 Go to the Overland Storage Web site at: www.overlandstorage.com 2 Click SERVICE & SUPPORT. 3 Log on via the MEMBER LOGIN section. For more information, see Registering Your Product on page 159. 4 Click KNOWLEDGE CENTER. Click here. 5 In the Browse Documents by Category section, click Technical. Click here. 148 X Updating the Appliance Setup Guide 6 In the Sub-Categories section, click REO Software and Release Notes. Click here. 7 In the list of results that appears, click the link to the applicable release to download the files. Click the applicable link. Checking For and Downloading Updates W 149 Overland Storage REO 9000 with ProtectionPAC Software Because of the size of the upgrade file, you must download it from the FTP server. You can use either a file transfer protocol (FTP) or hypertext transfer protocol (HTTP) to download the files. Click the applicable link to access the update. Download all files for the applicable release. 8 Download and save each attachment to your computer. Tip: If you want to be notified whenever a change is made to REO Software and Release Notes category, click Watch Category. 9 Save the files to a temporary location on the management system. 150 X Updating the Appliance Setup Guide Installing an Update Installing the upgrade does not affect any data that you currently have stored on the REO Appliance; however, Overland Storage strongly recommends that you back up any data on the appliance before you begin the upgrade process. 1 Log on to the software console. 2 In the software console, under System Menu, click Maintenance. Click Maintenance. 3 In the System Maintenance page, under REO Information, click Update REO. Installing an Update W 151 Overland Storage REO 9000 with ProtectionPAC Software 4 In the Update REO using Downloaded File section, type the path name to point to the file that you downloaded, or click Browse to point to it, and then click Submit. 5 When the confirmation message appears, click OK. 6 When the message appears that indicates the file was successfully uploaded, click Update. 7 When the confirmation message appears, click OK. 8 Wait approximately five minutes before logging back on to the REO Appliance. 9 In the software console, under System Menu, click Maintenance. 152 X Updating the Appliance Setup Guide 10 In the REO Information section, note that the Product Version now reflects the new version of the software. If applicable, the Flash Version might also be different. 11 If you are using the FC-enabled version of the product, complete the steps in the next section to determine whether an update for the firmware on the FC controller is available. Updating the Firmware on the FC Controller 1 Review the information listed in the REO Information section. If the firmware on your FC controller needs to be updated, you will see information similar to the following: 2 If the firmware needs to be updated, detach the FC cables from the REO Appliance, and then click Update REO. 3 In the Fibre Channel Firmware Updates section of the REO Update page, click Update FC Firmware. Installing an Update W 153 Overland Storage REO 9000 with ProtectionPAC Software 4 When the confirmation message appears, click OK to continue. 5 When the following message appears, attach the FC cables to the appliance. 6 Wait approximately five minutes before logging back on to the REO Appliance. 7 In the software console, under System Menu, click Maintenance. 8 In the REO Information section, note that the FC Firmware Version now reflects the new version of the firmware. 154 X Updating the Appliance D Specifications APPENDIX This appendix lists the specifications for the REO Appliance. Capacity Disk Drives Twelve or Twenty-four SATA × 250 or 400 GB Raw Capacity 9.6 terabyte (TB) RAID Levels JBOD, RAID 0, RAID 5 with hot spare Host Interfaces Hardware Two GbE Ports (RJ45) One Management Port (RJ45) Two Fibre Channel Ports (LC) Two Ultra320 SCSI Ports (VHDCI) Dual 3+1 RAID controllers Software USB Software Key Storage Protocol 1 gigabit Ethernet/iSCSI, 2 gigabit optical Fibre Channel Power Requirements Voltage 90 to 120 volts alternating current (VAC), 200 to 240 VAC +/– 10 percent Frequency 47 to 63 hertz (Hz) Current 6 A at 115 VAC, 3 A at 230 VAC Power Cord Connector IEC 60320 C13 Connector Power Consumption Steady state 500 watts; peak power 525 watts (fully populated) Enclosure Dimensions 19-by-27-by-8.75 inches (5U rack-mount) (48.26-by-68.58-by-22.22 centimeters) Weight 130 pounds (59 kilograms) Environmental Requirements Operating Humidity 20% to 80% non-condensing Temperature 50° to 95°F (10° to 40°C) Specifications W 155 Overland Storage REO 9000 with ProtectionPAC Software Altitude –984 to 10,000 feet (–300 to 3,048 meters) Shock 10 G (11 milliseconds half sine) Vibration .25 G swept sine (5–250–5 Hz) no errors Non-operating Humidity 10% to 95% non-condensing Temperature –40° to 140°F (–40° to 60°C) Altitude –984 to 39,370 feet (–300 to 12,000 meters) Shock 20 G (11 milliseconds half-sine pulse) Vibration 1.0 G swept sine (5–250–5 Hz) Agency Approvals Safety and Emissions TUV NRTL U.S./Can, GS (German, TUV), VCCI, BSMI (Taiwan) Backup Software Interoperation BakBone NetVault CommVault Galaxy Computer Associates BrightStor ARCserve LEGATO NetWorker Microsoft Windows 2000 Backup utility Syncsort Backup Express VERITAS Backup Exec for Windows NT and Windows 2000 VERITAS NetBackup Warranty For warranty information, see the Web site: www.overlandstorage.com Electromagnetic Emission Notice This equipment has been tested using shielded cables for EMIcompliance. The use of unshielded cables or modifications requires system testing for EMI testing for compliance to the standard. Industry Canada This Class A digital apparatus complies with Canadian ICES-003. Industrie Canada Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 156 X Specifications Setup Guide communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Japan Voluntary Control Council for Interference (VCCI) Translation This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may occur, in which case, the user may be required to take corrective actions. Taiwan BSMI Class A Warning Electromagnetic Emission W 157 Overland Storage REO 9000 with ProtectionPAC Software Declaration of Conformity 158 X Specifications E Customer Support APPENDIX If you have a technical question about the REO Appliance, try the following: 1 Check the documentation and online Help. 2 Check the Web site: www.overlandstorage.com Updates and Release Notes for the latest versions of the REO Appliance products are available from the Overland Storage Web site. The Release Notes include guidelines for upgrading the software and firmware, describe modifications and enhancements made to the product, and identify issues that you should be aware of when using the product. (For more information, see Checking For and Downloading Updates on page 148.) After you register your product via the Web site, you can view and download the Release Notes, as well as any other applicable documentation, such as the latest version of the Setup Guide. Registering Your Product 1 Go to the Overland Storage Web site at: www.overlandstorage.com 2 Click SERVICE & SUPPORT. 3 If you have previously registered other products, log on via the MEMBER LOGIN section; otherwise, click SIGN UP NOW, and follow the onscreen steps to create a logon account. 4 Under MY PRODUCTS, click Add or Register a New Product. 5 Enter the serial number of your REO Appliance (usually located on the back of the unit) and delivery date, and click SUBMIT. Customer Support W 159 Overland Storage REO 9000 with ProtectionPAC Software You can use the Product Selector to select a product and view information about it. Locating Additional Information for Your Product 1 Go to the Overland Storage Web site at: www.overlandstorage.com 2 Click SERVICE & SUPPORT. 3 Log on via the MEMBER LOGIN section. 4 Click KNOWLEDGE CENTER. Click here. 5 In the Browse Documents by Category section, click Technical. 6 Use the Search Category feature to search for a specific phrase. You can also open one of the subcategory folders and search from within it. 160 X Customer Support Setup Guide 7 If you still have a question, use the following contact information: For Contact Worldwide Headquarters Overland Storage, Inc. 4820 Overland Avenue San Diego, CA 92123 Toll Free: 1.800.729.8725 Tel: 1.858.571.5555 Fax: 1.858.571.3664 Sales Telephone: 1.858.571.5555 Fax: 1.858.571.3664 E-mail: sales@overlandstorage.com Technical Support Telephone: Worldwide: 1.858.571.5555 EMEA: +44 (0) 118.9898050 Fax: 1.858.571.3664 E-mail: support@overlandstorage.com Locating Additional Information for Your Product W 161 Overland Storage REO 9000 with ProtectionPAC Software 162 X Customer Support Glossary and Acronym List Application server. A networked computer on which production programs are running. The programs on an application server typically handle application interaction between an end-user’s browser-based programs and a company’s back-end database or business applications. (While the application server runs the programs and processes requests, the actual programs and data are usually stored on a file server.) Backup server. A networked computer that actually stores copies of files from other computers or servers or that runs backup software that automates the backup process of moving copies of files to separate storage medium, such as tape. D2D. Disk-to-disk D2D2T. Disk-to-disk-to-tape DHCP. Dynamic Host Configuration Protocol File server. A networked computer on which programs and data files are stored. (While the application server runs the programs and processes requests, the actual programs and data are usually stored on the file server.) GbE. Gigabit Ethernet HBA. Host bus adapter Internet SCSI (iSCSI). A standard protocol for universal access to shared storage devices over standard, Ethernet-based transmission control protocol/Internet protocol (TCP/IP) networks. The connectionoriented protocol transports SCSI commands, data, and status across an IP network. The iSCSI protocol enables block-level storage applications over TCP/ IP networks. It builds on two widely-used technologies—SCSI commands for storage and IP protocols for networking. iSCSI uses the SCSI command set, the core storage commands used throughout all storage configurations. iSCSI uses IP and Ethernet, the basis for most corporate, metropolitan, and wide-area networks. Glossary and Acronym List W 163 Overland Storage REO 9000 with ProtectionPAC Software iSCSI uses standard Ethernet switches and routers to move the data from server to storage. It also allows IP and Ethernet infrastructure to be used for expanding access to storage area network (SAN) storage and extending SAN connectivity across any distance. Tip: For more information about iSCSI, se the Internet Engineering Task Force (IETF) standards for IP storage at www.ietf.org (Internet Society, 2002. iSCSI (Draft), www.ietf.org/internet-drafts/draft-ietfips-iscsi-13.txt). Initiator. The client is an initiator that plays the active role in issuing commands. In iSCSI terms, an initiator is a logical system component (usually present in the form of a device driver) that sends SCSI I/O commands to a target over an I/O bus or network. In this application, the initiator accompanies the initiator software or IP storage HBA on your application or backup server. iSCSI target. The server is a target that plays the passive role in fulfilling client requests. An iSCSI target is a logical system component within an iSCSI appliance that receives SCSI I/O commands from an initiator and executes them. A target includes one or more logical units (LUs); each LU is a SCSI device, such as a disk or tape drive. In this application, the target is the array of disks on the REO Appliance. FC. Fibre Channel FC-AL. Fibre Channel Arbitrated Loop FC-SW. Fibre Channel Switched JBOD. Just a bunch of disks LAN. Local-area network LTO-2. Linear tape-open LU. Logical unit LUN. Logical unit number LVM. Logical volume management Mail server. A networked computer that stores and processes incoming and outgoing e-mail. Media server. A VERITAS Backup Exec server that runs the Backup Exec engine. (Outside the VERITAS backup environment, a media server usually refers to a server that handles the transmission of audio and video information, such as a streaming-media server.) Medium Changer. A secondary device that automates the movement of media to and from a primary device. NIC. Network interface card Print server. A networked computer that stores and processes print requests to a printer from an end-user’s computer and returns status information to the end-user. RAID. Redundant array of independent disks 164 X Glossary and Acronym List Setup Guide REO Device ID. The SCSI target presented to the initiators. SAN. Storage-area network SCSI. Small Computer System Interface Target. The target is a resource that receives and executes client requests. TCP/IP. Transmission Control Protocol/Internet Protocol TOE. TCP offload engine U (as in 2U). Unit; measures the height of a rack-mounted appliance. 1U is equal to 1.75 inches (4.445 centimeters). UPS. Uninterruptible power supply Volume. In this context, there are two types, physical and logical. The physical volume correlates directly to a physical disk drive in a JBOD or RAID configuration. A logical volume is based on a configuration and specification set by you. WWNN. Worldwide node name WWPN. Worldwide port name W 165 Overland Storage REO 9000 with ProtectionPAC Software 166 X Glossary and Acronym List Index A accessing appliance, prohibited 120 software console 99, 122 adding additional disks 112 appliances 107, 108 logical volumes 71 alarm 127 alerts audio 127 e-mail, configuring 58 appliance does not start 121 arbitrated loop topology 12 associating targets and initiators 87 B backing up configuration information 41 REO SoftKey 32, 97 beeping 127 BOOTPROTO field 34 BROADCAST field 34 C communication, driver or HBA 61 configuration file BOOTPROTO field 34 BROADCAST field 34 IPADDR field 34 modifying 33 NETMASK field 34 NETWORK field 34 configuring disk devices 73, 81 e-mail alerts in the console 58 FC 56 gateway 52 GbE data ports (Data Ports 1 and 2) 55 logical volumes 71 logon information 58 Management Port 52 management system 39 RAID 65 security in the console 58 shared devices 116 system information 57 systems used in the backup process 61 tape devices 73, 81 targets and initiators 91 time and date 60 tracking information 41 with the REO SoftKey 31 connecting Data Port 1 27 Data Port 2 27 External (SCSI) Devices 28 Fibre Channel Ports 27 Management Port 26 power cords 28 REO SoftKey 36 console accessing 99 changes not reflected 124 configuring targets and initiators in 91 unable to log on 122 creating disk devices 73, 81 logical volumes 71 tape devices 73, 81 critical errors, notifying Overland 58 customer support 159 D D2D2T backup capabilities 13 Data Port 1 (GbE) configuring 55 connecting 27 Data Port 2 (GbE) configuring 55 connecting 27 date, configuring in the console 60 disk devices 73 disks adding additional 112 faulty 129 mapping to the appliance 39 not visible in Windows Explorer 125 numbering of 104 dynamic tape 16, 77 E e-mail alerts, configuring in the console 58 eui 88 Index W 167 Overland Storage REO 9000 with ProtectionPAC Software expanding capacity adding appliances 107, 108 adding disks to an appliance 112 External (SCSI) Devices changing target name 84 connecting 28 detecting 81 External Device Summary page 103 External Initiator Summary page 103 F Fibre Channel (FC) 11 connecting ports 27 connecting to switch 27 entering network information 56 overview 12 topologies 12 G gateway address, verifying configuration 52 GbE data ports configuring 55 connecting to 27 H help 119, 159 host bus adapter (HBA) 11, 61 hot spares 16, 66 creating 68 recreating 141 I Initiator Summary page 102 initiators 11 associating with targets 87 configuring 91 installing in a rack 21 iSCSI client driver 61 requirements for the network 17 iSCSI initiators 17 Internet SCSI, see iSCSI IPADDR field 34 iqn 88 iSCSI architecture 11 initiators supported 17 naming conventions 87 protocol 11 linear tape-open (LTO-2) devices creating 73, 81 emulating 16 local-area network (LAN) 11, 13, 26 log file 120 logical unit numbers (LUNs) 16 logical volume management (LVM) 16, 71 logon information configuring 58 forgotten 128 M Management Port connecting to 26 verifying configuration 52 management system, configuring 39 mapping network drive to the appliance on each backup system 61 network drive to the appliance on the management system 39 systems restart 127 N N_Port 12 naming conventions for iSCSI 87 NETMASK field 34 network connecting to 27 connecting to the LAN 26 FC, entering information 56 installation requirements 17 safety guidelines 20 NETWORK field 34 network interface card (NIC) 61 NL_Port 12 numbering of disk drives 104 P password, forgotten 128 point-to-point topology 12 ports Data Port 1 27 Data Port 2 27 Management 26 N_Port 12 NL_Port 12 power attaching cords 28 turning off 105 J R just a bunch of disks (JBOD) changing to 63 forcing an Add 129 rack, installing in a 21 recreating a hot spare 141 redundant array of independent disks (RAID) changing the configuration 63 configuring 65 options 15 recreating a hot spare 141 removing the REO SoftKey 35 REO Device Summary 101 REO Devices, creating 73, 81 K key, see REO SoftKey L LEDs 104 168 X Index Setup Guide REO SoftKey backing up (post-configuration) 97 backing up (pre-configuration) 32 connecting 36 deleted files from 129 editing configuration file on 33 lost or damaged 129 overview 31 removing from a Windows system 35 Reset option 119 requirements 16 S safety guidelines, network location 20 scalability adding appliances 107, 108 adding disks 112 SCSI devices, see External (SCSI) Devices SCSI time-out value 18 security, configuring in the console 58 ShareDevice accessing a device 117 configuring 116 sharing access between systems 115 SoftKey, see REO SoftKey software console accessing 99 configuring targets and initiators in 91 specifications agency approvals 156 backup software interoperation 156 capacity 155 electromagnetic emission 156 enclosure 155 environmental requirements 155 host interfaces 155 power 155 warranty 156 storage adapters 11, 61 storage-area network (SAN) 11, 13, 27 summary pages External Device Summary 103 External Initiator Summary 103 Initiator Summary 102 overview 100 REO Device Summary 101 switched fabric topology 12 system, identifying in the console 57 systems used in the backup process, configuring 61 (TCP/IP) 11 troubleshooting 119 alarm 127 appliance does not start 121 beeping 127 changes not reflected in second browser window 124 faulty disk or appliance 129 forgot name or password 128 log file 120 lost or damaged key 129 systems restart after mapping 127 unable to access appliance 120 unable to connect to disk drives 125 unable to log on 122 U uninterruptible power supply (UPS) 28 UNIX, editing the configuration file 33 unpacking 19 USB key, see REO SoftKey user name, forgotten 128 V virtual tape 16, 73, 81 volumes creating logical 71 RAID options 15 W Windows environment, setting the SCSI time-out value 18 Windows Explorer, disks not visible 125 worldwide node name (WWNN) 12 worldwide port name (WWPN) 12 T tape devices creating 73, 74, 81 emulating 16 targets 11 associating with initiators 87 configuring 91 TCP Offload Engine (TOE) 61 time zone, configuring in the console 60 tracking configuration information 41 transmission control protocol/Internet protocol Index W 169 Overland Storage REO 9000 with ProtectionPAC Software 170 X Index
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2004:11:30 13:56:26-08:00 Create Date : 2004:11:30 13:32:41Z Page Count : 170 Creation Date : 2004:11:30 13:32:41Z Mod Date : 2004:11:30 13:56:26-08:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : Overland Storage, Inc. Metadata Date : 2004:11:30 13:56:26-08:00 Creator : Overland Storage, Inc. Title : REO Setup Guide Page Mode : UseOutlines Tagged PDF : YesEXIF Metadata provided by EXIF.tools