PAC EK-CON Access controller with low range proximity reader User Manual 17086

PAC International Limited Access controller with low range proximity reader 17086

Revised Manual

PAC INTERNATIONAL LTD, 1 Park Gate Close, Bredbury, Stockport, SK6 2SZ, EnglandTel: +44 (0) 161 406 3400. Fax: +44 (0) 161 430 8658www.pac.co.ukEasikeyInstallation and User Guide17086 Ver 3.3 DRAFT C January 2003
17086 Ver 3.3 DRAFT C  ii EasikeyVersion 3.3 January 2003Changes are periodically made to the product, these changes will be incorporated into neweditions of this manual.  PAC INTERNATIONAL LTD shall not be liable for errors containedherein or for any consequential damages connected with the use of this material.Copyright and Protective Notices1.  The copyright of this document and the associated drawings is the property of PACINTERNATIONAL LTD, and is issued on condition that it is not copied, reprinted orreproduced, nor its contents disclosed, either wholly or in part, without the consent in writingof, or in accordance with the conditions of a contract with PAC INTERNATIONAL LTD.2.  The publication of information in this document does not imply freedom from patent or otherprotective rights of PAC INTERNATIONAL LTD, or others.3.  Performance figures and data quoted in this document are typical, and must be specificallyconfirmed by PAC INTERNATIONAL LTD before they become applicable to any tender,order or contract.Training and Technical SupportTraining courses covering the installation and use of all PAC products are regularly held atPAC INTERNATIONAL LTD, Stockport.  For further information on course availability, or todiscuss your specific requirements, contact the Training Manager at the address below.It is strongly recommended that any persons installing or commissioning PAC productsattend a suitable training course beforehand.Technical Support for all PAC products is available during normal office hours:8:00am to 6:00pm Monday to Friday, excluding public holidays.Tel: 0161 406 3400 International +44 161 406 3400Fax: 0161 430 8658 International +44 161 430 8658This service is provided primarily for the use of trained engineers.  End users of PAC productsshould first of all contact their installation or maintenance company before contacting PAC.PAC INTERNATIONAL LTD1 Park Gate CloseBredburyStockportSK6 2SZEngland
17086 Ver 3.3 DRAFT C  iii EasikeyIMPORTANT:When installing the PAC equipment the following should be noted:HEALTH AND SAFETYInstallation must wired in accordance with National Wiring Regulations (BS7671, IEENational Wiring Regulations in the UK).  Failure to do so can result in injury or death byelectric shock.It must also comply with any local Fire, Health and Safety regulations.  A secured doorthat may be part of an escape route from an area must be fitted with:•A fail-safe lock (A) so that the door will be released if the power fails. Ideally amagnetic lock should be used as these are less likely to jam or seize.•A normally-closed break-glass or manual pull (B) in the lock supply wiring so that inan emergency the fail-safe lock can be immediately depowered.BAThe controller must be earthed.Isolate the controller supply before working on the controller.CABLINGThe cabling used in the PAC Access Control Systems (six wire bus, reader cables, etc.) are notprone to electrical interference. However, you should avoid routing cable close to heavy loadswitching cables and equipment.  If this is unavoidable, cross the cable at right angles every3.3-6.6ft/1-2m to reduce the interference.RFID DevicesAs similar RFID technology is now widely used in a number of other industries, for exampleautomotive immobilisers, it is possible that interaction between your access control ID and otherdevices may cause one or the other to function incorrectly. Should you suspect that you haveexperienced such a problem the solution is to separate your access control ID from other RFIDdevices.FCC NoticeThis device complies with part 15 of the FCC rules. Operation is subject to the following twoconditions (1) this device may not cause harmful interference, and (2) this device must acceptany interference received, including interference that may cause undesired operation.FCC ID   OQL-EK-CONChanges or modifications not expressly approved by the party responsible for compliance couldvoid the user's authority to operate the equipment.NoteThis equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, uses and can radiate radio frequency energy and, if not installedand used in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off and on, theuser is encouraged to try to correct the interference by one or more of the followingmeasures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to whichthe receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.
17086 Ver 3.3 DRAFT C  iv EasikeyThis page is intentionally left blank.
17086 Ver 3.3 DRAFT C  v EasikeyTable of Contents1.1 Facilities...............................................................................................................................11.2 Features...............................................................................................................................31.3 About this Guide ..................................................................................................................32.1 Components ........................................................................................................................42.2 How it Works........................................................................................................................42.3 Programming .......................................................................................................................43.1 Worksheets..........................................................................................................................53.2 Editor Keys ..........................................................................................................................53.3 Administering Keys ..............................................................................................................53.4 Residential Systems ............................................................................................................53.5 Easikey User Guide .............................................................................................................54.1.1 1. Present the new key to the controller reader.........................................................64.2 Possible Problems ...............................................................................................................65.1.1 1. Present the key to the controller reader. ...............................................................77.1.1 Dimensions.................................................................................................................87.1.2 Environment ...............................................................................................................87.1.3 Power Requirements..................................................................................................87.1.4 Fuses..........................................................................................................................87.1.5 Cable Requirements...................................................................................................89.1 The Easikey Controller ......................................................................................................109.2 Terminal Blocks .................................................................................................................109.3 Power Supply.....................................................................................................................119.3.1 Connecting Power ....................................................................................................119.4 Battery Backup ..................................................................................................................119.5 Readers .............................................................................................................................129.5.1 Request To Exit (RTE) .............................................................................................129.6 Reader Wiring....................................................................................................................129.7 Installing Locks and Power Supply....................................................................................139.7.1 Lock Suppression.....................................................................................................139.8 Note: Health and Safety.....................................................................................................139.9 Checking the System.........................................................................................................149.9.1 Controller Fuse.........................................................................................................149.9.2 Switches ...................................................................................................................1410.1 Initialisation ......................................................................................................................1510.2 Adding the Editor Keys ....................................................................................................1510.3 Setting the Lock Time......................................................................................................1510.4 Replacing a Lost Editor Key 1 .........................................................................................1613.1 Reader Wiring..................................................................................................................1813.2 Lock Wiring ......................................................................................................................1813.3 Programming ...................................................................................................................19
17086 Ver 3.3 DRAFT C  vi EasikeyThis page is intentionally left blank.
Introduction17086 Ver 3.3 DRAFT C  1 Easikey1. IntroductionEasikey 2-Door Controller:EasikeyEasikey Readers (Supplied Separately):Mullion Reader Vandal Resistant Reader Easikey Panel Mount Reader1.1 Facilities•  Simple Proximity Access Control•  Three Types of Reader•  Controls One or Two Doors•  Up to 99 Keyholders•  Up to Three Editor Keys•  Individual Keys may be Added and Deleted•  Each Lock may be Fail-Safe or Fail Secure•  Request to Exit Input•  Set/Reset Option, (e.g. for Alarm Setting)•  Dual Controller Option - 2 Doors, 198 Keyholders
Introduction17086 Ver 3.3 DRAFT C  2 EasikeyPHKGJCFEDNBLMA+            -BL<100m<100mEasikey System ConfigurationA B C   D Easikey ControllerEasikey ReaderPower Supply for Controller,Readers and LocksBattery BackupE F Door 1Door 2G H J K P Programming DisplayBlue ButtonGrey ButtonController ReaderRemovable CoverL M N Request to Exit Switch(on other side of door)Example: Magnetic LockExample: Electric ReleaseReaders may be:Mullion Reader (shown)Vandal Resistant ReaderPanel Mount ReaderLocks may be:Fail Secure, e.g. Electric ReleaseFail Safe, e.g. Magnetic Lock
Introduction17086 Ver 3.3 DRAFT C  3 Easikey1.2 FeaturesMaximum Number of Keys 99Number of Doors 2Types of Reader Mullion (Black or White)Vandal Resistant (Steel or Brass)Panel MountAccess Levels 3, (allowed through Door 1, Door 2 or Both Doors)Lock Release Time 1-48 secondsLock Type Fail-Safe or Fail-SecureNumber of Editor Keys Selectable (1,2 or 3)Other Features: Request to Exit Input Set/Reset LatchDatabase CopyDisplay Last 5 Users1.3 About this GuideThis document contains details on installing and using the Easikey system. Users andAdministrators should read the section How to Use Easikey. This section also describes howto use the Worksheets provided. Users should also read the sections on Adding Keys, DeletingKeys and Show Last Five Users. These sections are repeated on a one page User Guideincluded with the controller.Installers should read all of this Guide before continuing with the installation of the system. Ifyou are already familiar with this product then there is a Quick Start section which will remindyou of the stages of installing and programming the system.
Description17086 Ver 3.3 DRAFT C  4 Easikey2. DescriptionEasikey is a simple two door access control system using PAC's proximity readers andelectronic keys. The system allows you to control the access of up to 99 keys through one ortwo doors.2.1 ComponentsAn Easikey system consists of an Easikey door controller, one or two Easikey readers and up to99 keys. In addition you will require a power supply, cable and suitable electric locks. Optionalitems include Request to Exit switches and backup batteries. PAC also manufacture a BoxedEasikey, consisting of an Easikey controller housed in a steel cabinet, complete with 3A powersupply, space for backup batteries and complete internal wiring.2.2 How it WorksEach PAC key contains a unique code. The controller can store the code of up to 99 keys in itsnon-volatile memory. When a key is presented to a reader, the code in the key is passed by thereader to the controller. It is then compared to the codes in the controller's memory. If the key isrecognised by the controller then a relay will be operated allowing the release of an electriclock.2.3 ProgrammingAn Easikey system is programmed through the use of Editor Keys. The first one, two or threekeys in the controller's memory are defined as Editor Keys - you select how many at installation.By use of the Editor Keys, an operator may add and delete keys from the controller's memoryusing the built-in reader.A two digit display is used to indicate key numbers and lock times. The display also includestwo LEDs (light emitting diodes), red and green, for providing extra indications depending on thetype of operation being performed.
How to Use Easikey17086 Ver 3.3 DRAFT C  5 Easikey3. How to Use EasikeyThis section describes how you should use your Easikey system to its best advantage. Anyoneoperating or administering the system should read this section as well as becoming familiar withAdding Keys and Deleting Keys.3.1 WorksheetsSupplied with each Easikey controller is a set of worksheets. These should be used forrecording information about the system as well as for keeping a record of keyholders. Thefollowing paragraphs refer to the worksheets and how best to use them.3.2 Editor KeysAn Easikey controller can store up to 99 keys in its memory. Every one of these keys can beallowed through Door 1 only, Door 2 only or both doors. Up to three of these keys, known asEditor Keys, are also given the ability to make changes to the system - such as adding newkeys or deleting existing keys. When the system is first installed the number of Editor Keys isset to 1, 2 or 3, that is key numbers 1, 2 and 3. You should know how many keys are EditorKeys, if you do not, then find out from whoever installed the system. Note that there is a sectionon the Programming Worksheet to record this number.It is recommended that you assign two or three keys as editors, and keep at least one in a safeplace. Editor keys can be deleted and added just like normal keys. However if all your EditorKeys are lost then you will have to follow the procedure to replace Editor Key 1. You cannotchange the number of Editor Keys without clearing the whole memory.3.3 Administering KeysEach key added to the system is given a number, 01-99. The lowest available number isdisplayed when a new key is presented, although this can be changed to another unusednumber if necessary. When a key is deleted from the Easikey's memory, its number becomesavailable again.When you add a key to the Easikey system you need to record the number (01-99) it was given,and to whom it was issued. This is important so that if the keyholder loses the key you candelete it by entering its 2-digit number. Use the Worksheets supplied for this purpose.You can identify keys that have been found by presenting them to the controller reader. Their 2-digit number will be displayed, along with a red light. (If a green light is displayed, it means thekey is unknown to the Easikey).The worksheet has an unlabelled column in the keyholder section. You can use this forrecording your own information. Typically you may record Department or Office in a commercialsystem, or Flat, Building or Block in a residential system.Five different coloured pegs are available. These fit into the small hole on one side of the PACkey. You can use these pegs to identify different keys issued to one keyholder. A residentialsystem, for instance, may issue a red, blue and yellow key to one resident for use by theoccupants of one dwelling. If one key is lost they can refer to their 'red key' as being missing.The worksheets contain a column for indicating the colour given to a key.A grid on one side of the PAC key can also be used for physically marking a key. You put asmall scratch, or drop of paint or correcting fluid, in different boxes to identify individual keys.3.4 Residential SystemsA special worksheet is included that is designed for use in Residential applications. This isdivided into two parts, Non-Residents and Residents. You should use the top section forrecording personnel such as cleaners, maintenance staff, housing officers etc. and the lowersection for the residents.3.5 Easikey User GuideA one page User Guide (17085) is included with each door controller. This repeats most of thepage in this document on Adding and Deleting Keys.NoteThis page is reproduced as the Easikey User Guide (17085) included with the Easikeycontroller.
Adding Keys17086 Ver 3.3 DRAFT C  6 Easikey4. Adding KeysThe Easikey controller stores up to 99 keys in its memory. Each key is given a number from 1 to99. When a key is deleted from memory its number is free to be used again. When adding a keyit is automatically assigned the first free number. The operator can however, select a differentnumber, provided it is not being used by another key.4.1.1 1. Present the new key to the controller reader.  If the new key is valid then the first free number between 1 and 99 will appearwith a green LED. In this example key 12 is the first free number.2. To select a different number:•Press both buttons together. The display will flash briefly.•Select another number by using the grey button to increment the right handdigit and the blue button to increment the left hand digit. If a number isalready used then the display will flash.•When the number required is selected press both buttons again.  3. To Change the Access Level:The two small dots represent door 1 and door 2. When lit they indicate that thekey has access through those doors.•To prevent a key from gaining access to one of the doors press the blue(door 1) or grey (door 2) button. The corresponding dot will go out.•To allow access again press the same button again - the dot will comeback on. In this example key 12 will have access to door 1 only.  4. Present an Editor Key to the controller reader.The key is now confirmed as in the controller's memory and the display willclear, except for the green LED. and the access level dots.At this point you may:•Present the same Editor Key to clear the display.•Allow the display to time-out after 15 seconds.•Present another key to be added.5. Block Adding KeysOnce a key has been added as above then further keys can be added bypresenting them to the controller reader one after the other. You do not needto present an Editor Key again. Each key will be given the next free number,which can be changed as described above. Also the access level will stay thesame from one key to the next, unless changed.4.2 Possible Problems  Key Already In MemoryIf the key already exists in the controllers memory then its number, 01-99, willappear in the display with the red LED. lit.  Memory FullIf the Easikey is full then 00 will appear, flashing, in the display.
Deleting Keys17086 Ver 3.3 DRAFT C  7 Easikey5. Deleting KeysThere are two ways of deleting a key:If you have the key then:5.1.1 1. Present the key to the controller reader.  2. If the key is in the controller's memory then its number will appear in thedisplay with the red LED. lit. (If the key is not in memory then the next freenumber will be displayed with the green LED. lit. )3. Present an Editor Key to the controller reader. The display will flash briefly andthe display will clear. The key is now deleted.If you do not have the key:  1. Use the blue and grey buttons to enter the key number. Press the grey button- the display will change to 00 with the red LED. lit. Press the blue button toincrement the left hand digit, the grey button to increment the right hand digit.2. If the number displayed is not used then the digits will flash.  3. When you have selected the key number to be deleted, present an Editor keyto the controller reader. The display will flash briefly and the display will clear.The key is now deleted.Editor KeysWhen the Easikey was installed the number of Editor keys was set to 1,2 or 3. This means thefirst 1,2 or 3 keys will be Editors. If an Editor key is deleted, then a key added back with thesame number will also become an Editor. Editor keys can only be deleted by the secondmethod described above, neither can an Editor key delete itself.6. Show Last Five UsersIt is possible to see the last 5 keys used by pressing the blue button. Press the button once tosee the last key used - the dot indicates which door was used, door 1 - left dot, door 2 - rightdot. Press the blue button again to see the previous keys used. Once the last 5 keys have beenviewed the display will clear.
Specification17086 Ver 3.3 DRAFT C  8 Easikey7. Specification7.1.1 DimensionsController (WxHxD, mm)198 x 90 x 28Readers see 17063 Easikey Reader Data Sheet7.1.2 EnvironmentTemperature Controller 0C to +50CReader -15C to +60CHumidity (RH)Controller  0% to 90%(non-condensing)Reader Sealed Construction7.1.3 Power RequirementsController: Input Voltage 10.5v to 20v DC8v to 14.5v AC 50/60HzCurrent 190mA (Max.)Reader: Current 90mA (Max.)7.1.4 FusesF1, Power fuse on PCB, 1A, 20mm glass, Quick Blow7.1.5 Cable RequirementsController to Reader:Gauge 0.22mm², 4 or 6 coreMax. Dist. 100mController to Lock:Gauge 0.5mm², 2 coreMax.Dist. 100m
Quick Start17086 Ver 3.3 DRAFT C  9 Easikey8. Quick StartIf you have installed an Easikey system before then you can follow this simple step-by-stepprocedure to get the system up and running.If you are new to Easikey then all the steps below are described in detail in the following pages.1. Install the Easikey controller, complete with power supply, in an enclosure or other securearea. (The Boxed Easikey, 21275, makes this stage easier)2. Install the readers and reader cables, including request to exit switches, if used.3. Install the electric locks and their cables.4. Initialise the Easikey, set the number of Editor Keys and add one or more keys.5. Set the lock release time for each lock.6. Check the operation of each reader and lock.7. Add any remaining keys to the controller - use the Worksheet to record details of keyholders.
Installation17086 Ver 3.3 DRAFT C  10 Easikey9. InstallationInstallation is only to be carried out by competent, qualified and experienced personnel.Wire in accordance with the country of installation’s National Wiring Regulations (UKBS7671, IEE National Wiring Regulations). Failure to do so can result in injury or deathby electric shock.Note that a 'Boxed Easikey' (Part No. 21275) is available, complete with cabinet, 3 Amppower supply, internal wiring and space for two 6Ah batteries. If this is being used thenfollow the instructions supplied with it for installation and power supply.9.1 The Easikey ControllerThe controller should be mounted in a lockable cabinet or enclosure containing the powersupply and batteries (if used). It should be easily accessible for programming - the displayshould be at about eye level. A mounting plate is provided. When using the mounting plate usetwo countersunk screws. Take care not to over-tighten the screws as distortion of the backplatemay make it difficult to mount the controller.1989039 120 394050Easikey Backplate Dimensions (mm)9.2 Terminal Blocks  P1   P2 L1    L2   -V1  S1   R1   A1  +V1 L3    L4   -V2  S2   R2   A2  +V2AB C D ETerminal Markings FunctionAP1  P2 Power Input, AC orDCBL1  L2 Lock 1 OutputC-V1  S1  R1  A1+V1Reader Channel 1DL3  L4 Lock 2 OutputE-V2  S2  R2  A2+V2Reader Channel 2All connections are made to the controller by removable terminal blocks. Always remove powerfrom the controller before removing a terminal block.
Installation17086 Ver 3.3 DRAFT C  11 Easikey9.3 Power SupplyThe Easikey controller and readers are powered from a 12v AC or DC power supply. The locksare controlled by switching power from the same or different supply. The relays that control thelocks are able to switch 24v AC or DC at up to 2 Amps. A power supply with battery backupshould be selected to provide operation when mains power is lost.The power supply chosen should be capable of supplying sufficient current to power theEasikey controller, one or two Easikey readers, one or two electric locks and provide chargingcurrent for the battery.Use the following table to ensure you do not overload the power supply:Item Current (mA)Easikey Controller 190Easikey Reader 1 90Easikey Reader 2 90Lock 1Lock 2Charging Current 500Safety Margin 500TotalThe total current should not exceed the rating of your power supply (or supplies).9.3.1 Connecting PowerPower is supplied through the P1 and  P2 terminal block. See the section Installing Locks fordetails of power and lock wiring.9.4 Battery BackupThe length of time that a backup battery will last depends on the power consumption of thesystem. The main factor in this calculation is the power consumption of the locks. A fail-safelock draws current continuously and therefore you add the continuous current to the total. A fail-secure lock only draws current when it operates. In this case you need to estimate how oftenthe lock will operate and use the following equation to estimate consumption:Lock Current(mA) x ( no. of operations per hour x lock release time (secs)) / 3600Example: a 500mA lock operating 100 times an hour for 5 seconds would use500 x (100 x 5) / 3600 = 69mA per hour.Once the total power consumption has been estimated then it can be calculated how long thefully charged batteries will last. The Ah rating of batteries is usually given as a 10 hourdischarge rate. If the batteries discharge over a shorter period of time they will last for less thantheir quoted capacity.Example: an Easikey with two readers and two continuous (fail-safe) locks each drawing250mA would consume 190 + 90 + 90 + 250 + 250 = 870mA. A fully charged 12Ah batterywould last 12 / 0.870 = 13.7 hours.
Installation17086 Ver 3.3 DRAFT C  12 Easikey9.5 ReadersInstall readers according to the instructions supplied with each reader. Readers are  usuallyinstalled at about door handle height on the unhinged side of the door.All readers have the same wiring terminals, and are fitted with a green led that illuminates whenaccess is allowed., and stays illuminated for the duration of the lock release time.The maximum distance of a reader from the controller is 100m.If two readers are fitted then they must be at least 300mm apart.You must only use Easikey readers - no other type of reader is suitable.9.5.1 Request To Exit (RTE)A Request to Exit switch may be fitted on the secure side of the door. This should be anormally-open switch that closes momentarily when pressed and released. Do not allow thewiring for the RTE switch to be visible if the reader is removed from the wall.9.6 Reader WiringIf you do not intend to use the RTE switch then 4-core cable will be suitable, otherwise use 6-core cable. -V1   S1  R1  A1  +V1+V SIGVCA -VEasikeyAB C100 mAReader Wiring, including RTEATerminal Block BRTE CReaderUse 7/0.2mm (0.22mm²) 4-core or 6-core unscreened cable.Controller: Reader: Colour:Channel 1 Channel 2+V1 +V2 +V RedS1 S2 SIG BlueR1 R2 n/c WhiteA1 A2 VCA Yellow-V1 -V2 -V BlackNotePAC strongly recommend that you fit a 100mA in-line fuse across the reader supply.
Installation17086 Ver 3.3 DRAFT C  13 Easikey9.7 Installing Locks and Power Supply P1   P2  L1   L21 L3   L4AZ ZXASingle Power SupplyXFuse ZMOVLocks should be installed according to the manufacturers instructions. The Easikey controls theoperation of a lock by switching power using a voltage-free relay. Up to 24v AC or DC at 2Amps may be switched by the relays. Each lock may be programmed to be fail-safe(continuously powered, power removed to unlock) or fail-secure (power supplied to unlock). Thetype of cable used should be sufficient to provide the correct operating voltage at the lock.Usually at least 0.5mm² will be required for up to 100m.9.7.1 Lock SuppressionImportant: All Easikey readers are supplied with a suppression device, an MOV (metal oxidevaristor). This device should be fitted across the lock supply at the lock. These devices preventharmful back e.m.f. ('spikes') from damaging the Easikey controller. Failure to fit thesedevices may result in long term damage to the controller.9.8 Note: Health and SafetyAny installation must comply with any local Fire, Health and Safety regulations. A secured doorthat may be part of an escape route from an area should be fitted with:•A Fail-Safe lock (A). So that the door will be released if the power fails. Ideally a magneticlock should be used as these are less likely to jam or seize.•A normally-closed Break-Glass or Manual Pull (B) in the lock supply wiring. So that in anemergency the fail-safe lock can be immediately depowered.
Installation17086 Ver 3.3 DRAFT C  14 EasikeyBA P1   P2  L1   L2  L3   L4Z ZXXB1 2BSeparate Power Supply for Controller and LockXFuse ZMOV9.9 Checking the SystemAfter completing the wiring of power supply, readers and locks you should make the followingchecks:1. Remove power. Remove all terminal blocks except for the power supply (P1 & P2). Applypower. You should have between 10.5 and 20v DC or between 8 and 14.5v AC across P1and P2.2. Remove power. Connect Reader 1 terminal block. Apply power. You should have between10 and 16v DC at the controller (+V1, -V1) and 9-16v DC at the reader (+V, -V).3. Repeat for Reader 2, if used.9.9.1 Controller FuseA 20mm 1 Amp fast blow fuse is fitted to the controller protecting both the controller and readersupplies.9.9.2 SwitchesFour switches are visible inside the controller near the fuse. These should always be off(switches towards the fuse).
Initial Programming17086 Ver 3.3 DRAFT C  15 Easikey10. Initial ProgrammingThe initialisation of the controller involves clearing its memory and assigning the number ofEditor Keys that will be used. Once the number of Editor Keys has been set then thenumber cannot be changed without clearing the Easikey memory. However Editor Keyscan be removed and added - see Adding and Deleting Keys.Record the number of Editor Keys on the Programming Worksheet.10.1 InitialisationNote: This will clear the memory of the Easikey1. Power up the Easikey with both buttons pressed.  2. The green and red LEDs will be lit and the display will show 03. This is thenumber of Editor keys that may be selected. If you want to change the number ofEditor keys then press the grey button to cycle through 01,02,03.3. Press the blue button to confirm the number of Editors. The display will clear.10.2 Adding the Editor KeysThe first 1,2 or 3 keys to be added will be Editor keys. These keys will allow access as well asallowing changes to be made to the system.1. Present the first Editor Key to the front panel reader.  2. The display will briefly show the green LED. and the number 01. Both dots willbe lit indicating the key has access to both doors.The display will clear except for 2 dots and the green LED.  3. You may now present another key, which will become key 2. The display willbriefly display 02 and return to the green LED. and two dots.4. You can change the access of the Editor Keys (except number 1) - see AddingKeys for details.5. To finish adding the Editor Keys present the first key again. The display willclear.At this point you may continue adding keys as described in Adding Keys.10.3 Setting the Lock TimeEach of the two lock relays can be set to operate the  lock for between 1 and 48 seconds. Eachmay also be set to open or close when operated, allowing the use of fail-safe (power to lock) orfail-secure (power to unlock) locks.1. Present an Editor key to the controller reader.  2. The Editor Key number will appear - 01 in this example.•To set the lock release time for door 1 press the blue button.•To set the lock release time for door 2 press the grey button.  3. The display will show the number of seconds currently set.•The red LED. will flash for lock 1.•The green LED. will flash for lock 2.  4. Select a time by pressing:•the grey button to increment the right digit.•the blue button to increment the left digit.Add 50 to the lock release time for the relay to be normally closed (fail-safe).The example shows a fail-safe lock set to 5 seconds lock release time.
Set-Reset Latch17086 Ver 3.3 DRAFT C  16 Easikey5. Present the Editor key again to clear the display.10.4 Replacing a Lost Editor Key 1All Editor Keys, including number 1, can be deleted and a new key added in their place.However if all the Editor Keys are lost then the first key can be reinstalled using the followingprocedure:1. Remove power from the Easikey.2. Re-apply power with the blue button only pressed down.  3. The display will show 01 with the green LED. lit.4. Present a new key to the controller reader.5. The display will flash briefly before it clearsThe key presented is now Editor Key 1.11. Set-Reset LatchA special facility is available on lock 1 only that allows the lock relay to be set when a valid keyis presented, and reset when a valid key is presented again. This allows the reader to be usedlike a light switch to operate another system.To use this facility you should set the lock release time of door 1 to 99 seconds.NoteWhen this facility is used the Request to Exit facility for door 1 will no longer be available.
Database Copy17086 Ver 3.3 DRAFT C  17 Easikey12. Database CopyThis facility allows the contents of one Easikey's memory to be copied to another Easikey. Thereceiving Easikey will have the contents of its memory completely overwritten by the contentsof the sending Easikey.To perform this operation you need to connect reader terminal 2 of each Easikey with thefollowing cable:Use 0.22mm² reader cable, distance less than 10m.SendingControllerReceivingController-V2 ———— -V2S2 ———— A2A2 ———— S2+V2 ———— +V2Only one Easikey needs to be powered.SendingControllerReceivingControllerRemove power from both the  Easikeys.Connect reader terminal 2 of both Easikeys with the cable shownabove.Power up one Easikey.Present an Editor Key to the sending controller.  The Editor Key number will appear.Press both buttons on the sending controller.  The display will blank and the green LED. will be lit on the sendingcontroller. The receiving controller will show 00 plus the red LED.   Press the blue button on the sending controller. Both displays willnow count down from 10 to 01 with the LEDs flashing.   When the copy is finished the LEDs will stop flashing and a checknumber will be displayed. This should be the same on bothcontrollers. If not, then repeat the  operation.
Dual Controller Option17086 Ver 3.3 DRAFT C  18 Easikey13. Dual Controller OptionIt is possible to double the number of keyholders by connecting a reader to the same channelon two Easikey Controllers. If a key is found in either of the Controllers then the lock relay willoperate. The diagrams below show two controllers controlling one Lock 1. To control Lock 2,connect a single reader to channel 2 of both controllers, and the lock through terminals L3 andL4 of each controller. Note that power is supplied to both Easikey controllers.13.1 Reader WiringNotice that the reader wiring shown below includes a diode, (1N4001, not supplied) at each A1(or A2) terminal. This is essential to provide correct operation of the reader LED.The Request to Exit switch can be fitted to either controller - it is shown fitted to the secondcontroller. -V1 S1  R1 A1 +V1+V SIGVCA -VEasikey -V1 S1  R1 A1 +V112LBYReader Wiring for Dual Controller Operation1Easikey Controller 12Easikey Controller 2LRequest to Exit BEasikey ReaderYDiodes, 1N400113.2 Lock WiringTwo different lock wiring configurations are required for Fail Secure and Fail-Safe locks. FailSecure locks are wired so that the relays are in parallel, that is whichever relay closes thenpower will be applied. Fail Secure locks are wired with the relays in series, so whenever onerelay opens then power will be removed.
Dual Controller Option17086 Ver 3.3 DRAFT C  19 Easikey  P1   P2   L1   L2  P1   P2   L1   L2  L1   L2  L1   L21212ZXPZXABP  P1   P2  P1   P2Power and Lock Wiring for Dual Controller OperationAUsing Fail Secure Locks, Relays in ParallelBUsing Fail Safe Locks, Relays in Series1Easikey Controller 12Easikey Controller 2PPower SupplyXFuse ZMOV13.3 ProgrammingBoth Easikeys should be installed and initialised as described in this manual. However, pleasenote the following:•You should add the same Editor keys to each Easikey.•Ensure that the Lock Release Times for each lock are programmed in exactly the sameway on each controller.•Note to which controller each key is added. If you need to delete a key then you must knowto which controller it was added.
Easikey System Troubleshooting17086 Ver 3.3 DRAFT C  20 Easikey14. Easikey System TroubleshootingProblem Possible Cause CheckEasikey Controller notWorkingNo Power Check AC (mains) power supply and fuse.Check voltage at P1, P2 terminals, should be10-16VDC or 10-12VAC.Fuse Blown Check controller Fuse (1 amp)Easikey controller OK,but neither readeroperates.No power at readers Check power at reader, should be 9-16VDC.Reader wiring incorrect Check wiringLock Release Times setto 0Change Lock Release Time to between 1and 48 seconds.Key not added Add key to systemOne reader OK, butother is not.No power at reader Check power at reader, should be 9-16VDC.Reader wiring incorrect Check wiringLock Release Time set to0Change Lock Release Time to between 1and 48 seconds.Key does not haveaccessCheck key has access through both doors.Display 'counts' from0-99Switches incorrectly set. Switch all switches OFF, towards fuse.System fails when alock operatesPower supply overload Power supply is not capable of supplyingenough power to operate lockLock is faulty and drawing too much currentfrom power supply.A key has stoppedworkingFaulty reader If the reader is faulty then other keys will alsofail to work - check the reader.Faulty key Other keys will work without problem -replace the key.Incorrect programming Check that the key exists in the controller,and it has been given correct access
Other Easikey Products17086 Ver 3.3 DRAFT C  21 Easikey15. Other Easikey ProductsThe following items are available for use with the Easikey 2-door Access Control System:Part No. Description Notes21275 Boxed Easikey Complete with Easikey Controller 3Amp psuand wiring.20377-Black20387-WhiteEasikey Mullion Reader For internal use.20378-Steel20388-BrassEasikey Vandal ResistantReaderFor external use or where resistance toabuse is required. Supplied with 4 VandalResistant Screws (requires 1950 Screwdriverbelow)20421 Easikey Panel MountReaderFor fitting in steel panels, e.g. as part of adoor entry system.925 Request to Exit Switch Large push switch for mounting on single-gang back box.980 Battery 12v 6Ah590-594 Coloured pegs:Red, Yellow, Blue, Green,WhiteFor fitting into PAC keys.1950 Screwdriver For Vandal Resistant Screws used on VandalResistant Reader
Other Easikey Products17086 Ver 3.3 DRAFT C  22 EasikeyDeclaration of ConformityApplication of Council Directives 73/23/EECStandard(s) to which conformity is declared EN55022-B,  EN55082-1. EN60950.Manufacturer's Name PAC International Ltd.Manufacturer's Address 1 Park Gate Close, Bredbury, Stockport, U.K. SK6 2SZ.Type of Equipment Access control systemsProduct Equipment Easikey SeriesI, the undersigned, hereby declare that the equipment specified above conforms to the above directive(s) andstandard(s).Signed Date 1st September 1995Full Name Vanda Murray Position Chief Executive