PAC EK-PNL Low range proximity reader User Manual 17063

PAC International Limited Low range proximity reader 17063

Revised manual

DATASHEETPAC INTERNATIONAL LTD, 1 Park Gate Close, Bredbury, Stockport, SK6 2SZ, EnglandTel: +44 (0) 161 406 3400. Fax: +44 (0) 161 430 8658www.pac.co.ukEasikey ReadersMullion, Vandal Resistant and Panel Mount17063 Ver 1.6 DRAFT B January 200320377 Mullion Reader-Black20387 Mullion Reader-White20378 Vandal Resistant Reader-Steel20388 Vandal Resistant Reader-Brass20421 Panel Mount ReaderCAUTIONThese readers are suitable for connection toEasikey and Easikey 1000 only. They shouldnot be connected to any other type ofequipment (e.g. PAC 2100/2200 series).1. IntroductionMullion Vandal Resistant * Panel Mount *Items EnclosedMullion reader Vandal resistant reader Panel mount reader and head4 terminal screws 4 terminal screws 4 terminal screwsMOV MOV MOVMounting backplate 4 x 1¼" No. 8 VR screws Lexan window and backplateLabel2 x 1" No.6 self-tappingscrewsA special screwdriver(available separately) isrequired for the VandalResistant (VR) screws.NoteThe readers come with a 6-wire suppression lead that should be installed as described inthis datasheet.  This cable must be installed to comply with CE regulations.DimensionsH x W x D mm83 x 3.38 x 12H x W x D mm100 x 100 x 12H x W x D mm92 x 62 x 15  Reader60 x 60 x 12  HeadMaximum Reading Range 25mm 8mm 8mm
Introduction17063 Ver 1.6 DRAFT B  2 Easikey ReadersSpecification  for all readersOperating Temperature: -40C to +50CCurrent: 90mA (maximum)Supply Voltage:  9-16v DC (supplied by the controller)Cable Type:  4 or 6-conductor, multi-stranded, unscreenedCable Distances:  Up to 100m from controller using 7/0.2 (0.22mm²)RFID DevicesAs similar RFID technology is now widely used in a number of other industries, for exampleautomotive immobilisers, it is possible that interaction between your access control ID and otherdevices may cause one or the other to function incorrectly. Should you suspect that you haveexperienced such a problem the solution is to separate your access control ID from other RFIDdevices.FCC NoticeThis device complies with part 15 of the FCC rules. Operation is subject to the following twoconditions (1) this device may not cause harmful interference, and (2) this device must acceptany interference received, including interference that may cause undesired operation.Mullion Reader FCC ID OQL-EK-MULVandal Resistant Reader FCC ID   OQL-EK-VNPanel Mount Reader FCC ID   OQL-EK-PNLChanges or modifications not expressly approved by the party responsible for compliance couldvoid the user's authority to operate the equipment.
Installation17063 Ver 1.6 DRAFT B  3 Easikey Readers2. Installation2.1 Mullion Reader - Installation8410 3603812124ABThis reader comes in two parts, the reader itself (A) with 4 terminals and the backplate (B). Thebackplate has a 3mm rubber spacer at the rear.2.1.1 Fixing the Reader1.  The cable from the controller should be routed through the aperture in the backplate. Leaveenough cable exposed to allow easy wiring of the reader (at least 20mm).NoteThere is limited room between the reader and backplate. You should ensure there is avoid large enough behind the backplate to accommodate any excess on the suppressioncable.2.  Fix the backplate to a flat surface using the No.6 screws provided - or a fixing suitable forthe material to which the reader is being mounted. The two holes are 60mm apart. Use thetop (round) hole first, and the lower (oval) hole to ensure the reader is straight.3.  Ensure that the reader cable is not connected to the controller. Wire the reader to the cableas described in the documentation supplied with the controller.4.  Push the reader, with the green LED to the top, onto the backplate, the fixing tabs on eachside should snap into place.5.  5. Place label on front of reader.2.2 Removing the ReaderThe reader can be removed from the backplate by placing a small flat-bladed screwdriver intothe apertures on each side of the backplate. Take care not to damage the reader or backplate.
Vandal Resistant Reader - Installation17063 Ver 1.6 DRAFT B  4 Easikey Readers3. Vandal Resistant Reader - Installation12100100707055This reader should be mounted using the Vandal Resistant screws provided.NoteA special screwdriver (not supplied) is required to use these screws.3.1 Fixing the ReaderThe cable from the controller should come to the rear of the reader. Leave enough cableexposed to allow easy wiring of the reader (at least 20mm).NoteThe terminals protrude 5mm from the rear of the reader. You should ensure there is avoid large enough (about 40mm square and 20mm deep) behind the reader toaccommodate the terminals and excess suppression cable.1.  Ensure that the reader cable is not connected to the controller. Wire the reader to the cableas described in the documentation supplied witrh the controller.2.  Apply a silicone sealant to the terminals to protect against moisture if the reader is mountedoutside.3.  Fix the reader to as flat and even a surface as possible. This will reduce the possibility of itbeing levered from the wall. Either use the Vandal Resistant screws provided, or othersuitable fixings. The LED should be to the top.
Panel Mount Reader - Installation17063 Ver 1.6 DRAFT B  5 Easikey Readers4. Panel Mount Reader - Installation907060421460484060460A B C DEFG15This reader is designed to be mounted in a steel panel (E), such as used in a door-entrysystem. There are two main units; the main module, a black rectangular unit, connected by afixed length of cable to a reading head. The cable between the two parts is fixed, 60mm longand should not be cut, extended or shortened.4.1 Panel ApertureThe reading head is designed to fit a 40mm square hole. Holes on the reading head, 48mmbetween centres, accept M3 fixing studs (F). The studs should be at least 15mm long. The frontcover (A) protrudes 2.5mm through the aperture.4.2 Locating the Main ModuleMount the module in a convenient place behind the panel. The holes in each corner will acceptNo. 6 screws. Ensure that the module is close enough to the reader head to allow the panel tobe removed without straining the cable. Wire the Module to the cable as described in thedocumentation supplied with  the controller.4.3 Fixing the Reading HeadThere are 4 components to the reading head:1.  Remove the protective film from the front lexan window (A). Mount on the studs so that thecentre fits through the aperture, with the shallow slot to the bottom.2.  Remove the backing from the label, and fit to the circuit board (C), the clear hole shouldalign with the green LED.3.  Place the circuit board (C) and label over the studs against the window with the cable facingaway from the aperture.4.  Fit the rear lexan cover (D) and clamp using screws suitable for the studs (G).
Reader Wiring17063 Ver 1.6 DRAFT B  6 Easikey Readers5. Reader Wiring5.1 General Tips•  The cable distance from controller to reader should never exceed 100m.•  If using a Request to Exit switch, ensure that the wiring is not accessible if the reader isremoved.•  Ensure that the LED is always visible to the keyholder.NoteThe wiring and location of readers is fully described in the documentation supplied withthe controller. All the readers described on this sheet have identical terminals. It isstrongly recommended that a 100mA in-line fuse is fitted across the reader supply.5.2 Connecting the Suppression CableOne end of the 6-core suppression cable is connected to the reader and the other is connectedto the cable connected to the reader channel on the controller. The suppression cable comeswith four spade crimps at one end for easy connection to the PEMs on the reader. Crimp wirejoints are provided for connection to the reader cable from the controller.The following table details suppression cable connections to both the reader and to the readercable from the controller.NoteStandard 6-core alarm cable is usually used for the Controller Reader cable. Care mustbe taken if this is not the case or if a different colour convention is used than that given inthe table.Suppression Cable Controller Reader CableColour ReaderConnectionColour Easikey Easikey1000Black  -V  Black  -V1/-V2 VSIGGreen  SIG Green  S1/S2Blue -V  Blue n/c DCBrown  -V Yellow R1/R2 RTEWhite  VCA White A1/A2 VCARed  +V  Red +V1/+V2  V+The following diagram is how we recommend that the cable is wired.V+ VCA V- SIG Red White Green Blue Black Brown Black Green Blue Yellow White Red Junction     Box 6-core alarm  cable to reader channel on door controller Black Green Blue Brown White Red Door Contact RTE Suppression Cable
Reader Wiring17063 Ver 1.6 DRAFT B  7 Easikey ReadersNotes1.  The ends of any cores not used on the suppression cable can be snipped off.2.  If the controller is an Easikey then there is no Door Contact option available and theBrown core on the suppression cable is not used.5.3 MOV - Lock SuppressionA metal-oxide-varistor (MOV) is provided with each reader. This device prevents back e.m.f.('spikes') being returned from the electric lock to the controller. This can cause severe damageover a period of time, and erratic operation of the system if not controlled.A BThe MOV (A) should be fitted across the power terminals of the lock (B). It can be fitted acrossthe relay contacts on the controller, but this will be less effective.Important NoticeIf the reader is installed externally, then the terminals on the rear of the readerMUST be sealed with a silicone compound to prevent corrosion.
Reader Wiring17063 Ver 1.6 DRAFT B  8 Easikey ReadersDeclaration of ConformityApplication of Council Directives 73/23/EECStandard(s) to which conformity is declared ETS 300.683Manufacturer's Name  PAC INTERNATIONAL LTDManufacturer's Address 1 Park Gate Close, Bredbury, Stockport, U.K. SK6 2SZType of Equipment Access Control SystemsProduct Equipment  Easikey Reader RangeI, the undersigned, hereby declare that the equipment specified above conforms to the above directive(s) andstandard(s).Signed Date 20th November 1995Full Name Vanda Murray Position Managing Director

Navigation menu