PAC P-PIN Low range proximity reader User Manual 15826jf

PAC International Limited Low range proximity reader 15826jf

Manual

Data SheetJanuary 2003 15826 Ver 1.8 DRAFT CPAC Portico, 1 Lower Ragsdale Drive, Building 3, Suite 800, Monterey, California 93940 USAwww.PACPortico.comThis document is correct at the time of going to press. However, as part of our ongoing product enhancement programwe reserve the right to make changes to the product and/or literature at any time without prior notice.PAC Portico PIN Reader Installation GuideSurface and Flush MountedIntroductionThis data sheet describes the PAC Portico Surface Mounted PIN Reader and PAC PorticoFlush PIN Reader (pictured below).Surface Mounted  Flush Mounted  LED KEYPAD READER ApplicationThe PIN reader is of particular use in high security applications, having the extra security of aPersonal Identification Number (PIN) number as well as a PAC Portico key (or card). The use oflow cost, unscreened, signal alarm cable is recommended to connect the reader to the doorcontroller.General Description and OperationTo gain access through a door the user must first present a valid PAC Portico key to the built-inreader. Once the key has been read, the Light Emitting Diode (LED) will momentarily changefrom red to green.The user must then enter their 4-digit PIN number via the keypad. The LED will blink green andthe built-in sounder will beep as each key is pressed. Once the PIN has been entered, if the PINis correct, the LED will become green to indicate the door is unlocked.If the PIN is incorrectly entered, four further attempts may be made to gain access (by re-presenting the key and re-entering the PIN) before the individual key becomes locked out. Thelock-out is cleared when a different key is used.Once a key becomes locked out, it remains locked out for 2 hours; this lock-out period willexpire when the key has not been presented to the reader during that 2 hour period. Using akey when it has been locked out, will cause the lock-out period to be increased by 2 hours.
15826 Ver 1.8 DRAFT C PAC Portico PIN Reader Installation GuidePage 2 © 2003  Blick USA, IncExampleIf a locked out key is presented to a reader 10 minutes before its 2 hour period iscompleted, the lock-out period will be extended to 2 hours 10 minutes.A duress facility is available which may be activated by the user adding 1 to the last digit of theirPIN (i.e. PIN numbers of 1234 has a duress code of 1235). The duress code will open the doorand will also set off a predefined signal, such as an alarm (this feature will need to beconfigured separately with a standalone system or through PAC Portico for Windows).The use of a PIN number is optional and may be controlled by a time profile (i.e. at certain timesa key only may be required to gain access, at other times a key and PIN must be used).NoteEach PIN number is derived from the key and cannot be changed.The reader is not prone to electrical interference from normal electrical equipment, howevercare should be taken to avoid mounting the reader and cables in close proximity to heavy loadswitching cables and equipment.The performance of the readers is unaffected by the material of the mounting surface but makesure the mounting surface is as even as possible to provide maximum protection to the reader.Try to mount the reader at a height which it is easy to operate at; a recommended height for anable bodied person is 5.0-5.6ft/1.5-1.7m. Also the reader should be in a well lit place.Reader Installation It is not recommended to mount the reader externally but if it is installed externally, allexposed terminals on the reader and the connector strip must be protected by aproprietary sealant, e.g. silicone rubber compound. Use the reader as a template in order toaccurately mark the fixing points onto the mounting surface.Flush MountedThis reader is designed to be flush mounted onto a standard 2 gang (1.4in/35mm) back box usingthe two M3.5 (1in/25mm x 0.14in/3.5mm) screws provided.The connecting cable can be taken directly from the terminals through the knock-outs in theback box via a suitable grommet and through a suitably prepared hole in the mounting surface.The dimensions of the flush mounted reader are 4.0in/100mm x 5.8in/144mm.
PAC Portico PIN Reader Installation Guide 15826 Ver 1.8DRAFT C© 2003 Blick USA, Inc Page 3Surface MountedThe reader is designed to be surface mounted onto a flat surface using the two holes provided,therefore not requiring the installation of a back box. The readers performance is unaffected bythe material of the mounting surface. Ensure the surface is as even as possible to providemaximum protection against the reader being levered from the wall.The connecting cable can be taken via the hole provided on the lower section of the readerhousing and then surface mounted, preferably under the protection of a suitable conduit.Alternatively, the cable could be taken directly from the terminals through a suitably preparedhole in the mounting surface so as to be completely hidden from sight.The holes are designed to accept size No.8 countersunk screws, preferably anti-tamper type, witha recommended minimum length of 2in/50mm. This recommended length of course depends onthe surface type and construction.The dimensions of the surface mounted reader are 8in/200mm x 4in/100mm x 1.3in/30mm.ConnectionsReader ConnectionsThe connections for both readers are:Color Signal NotesBlack 0V Negative supplyWhite SIG Reader signalBrown VCA Valid code accept LEDRed +12V Positive supply
15826 Ver 1.8 DRAFT C PAC Portico PIN Reader Installation GuidePage 4 © 2003  Blick USA, IncCable LengthsThe cross-sectional area determines the cable length:Cable Gauge Easikey PAC 2100SeriesPAC 2200SeriesPAC 20224AWG/0.22mm2240ft/80m 325ft/200m 66ft/20m20AWG/0.5mm2550ft/180m 1500ft/500m18AWG/1.0mm23000ft/1000m 2250ft/700mSpecification•  Keypad: 10-digit rigid membrane keypad with visual target area for key presentation.•  LED Indicator: Red LED flashing momentarily to green showing electronic key acceptanceand PIN code entry, continuous green indicates correct code entry.• Reader range: 0-0.6in/0-15mm.•  Supply voltage: 12-18V dc (supplied from controller).•  Cable: 4 or 6-way (4 required for reader) multi-stranded, unscreened standard signal/alarmcable.•  Environment:  Temperature: -49°F to 122°F (-45°C to 50°C).•  Relative Humidity: 0 to 90% non-condensing.•  MeanTime Between Failures: >100,000 hoursRFID DevicesAs similar RFID technology is now widely used in a number of other industries, for exampleautomotive immobilisers, it is possible that interaction between your access control credentialand other devices may cause one or the other to function incorrectly. Should you suspect thatyou have experienced such a problem the solution is to separate your access control credentialfrom other RFID devices.FCCThis device complies with part 15 of the FCC rules. Operation is subject to the following twoconditions (1) this device may not cause harmful interference, and (2) this device must acceptany interference received, including interference that may cause undesired operation.Surface Mount FCC ID OQL-P-S-PINFlush Mount FCC ID OQL-P-PINChanges or modifications not expressly approved by the party responsible for compliance couldvoid the user's authority to operate the equipment.

Navigation menu