PAC P-PNL Low range proximity reader User Manual 15729

PAC International Limited Low range proximity reader 15729

Manual

Data SheetJanuary 2003 15729 Ver 1.5 DRAFT DPAC Portico, 1 Lower Ragsdale Drive, Building 3, Suite 800, Monterey, California 93940 USAwww.PACPortico.comThis document is correct at the time of going to press. However, as part of our ongoing product enhancement programwe reserve the right to make changes to the product and/or literature at any time without prior notice.PAC ReadersLow Profile, Vandal Resistant and Panel Mount2001 Low Profile Reader-Black2001W Low Profile Reader-White2002 Vandal Resistant Reader-Steel2002W Vandal Resistant Reader-Brass2025 Panel Mount ReaderCAUTIONThese readers should only be used with systems thatuse PAC ID keys. For example, they should not beconnected to an Easikey controller.Low Profile Vandal Resistant Panel MountItems EnclosedLow profile reader Vandal resistant reader Panel mount reader and head4 terminal screws 4 terminal screws 4 terminal screwsMOV MOV MOVMounting backplate 4 x 1¼" No. 8 VR screws Lexan window and backplateLabel2 x 1" No.6 self-tappingscrewsA special screwdriver(available separately) isrequired for the VandalResistant (VR) screws.NoteThe readers come with a 6-wire suppression lead that should be installed as described inthis datasheet.  This cable must be installed to comply with CE regulations.DimensionsH x W x D in/mm3.94/100 x 3.46/88 x 0.47in/12H x W x D in/mm3.94/100 x 3.94/100 x 0.47/(12H x W x D in/mm3.62/92 x 2.44/62 x 0.59/15  Reader2.36/60 x 2.36/60 x 0.47/12  HeadMaximum Reading Range 2in/50mm 0.4in/10mm 0.4in/10mm
15729 Ver 1.5 DRAFT D PAC Readers Low Profile, Vandal Resistant and Panel MountPage 2 © 2003  Blick USA, IncInstallationCAUTIONS1.  The readers should not be mounted on metal.2.  The cable distance from controller to reader should not exceed the cable distancequoted in Section 0.3.  If using a Request to Exit switch, ensure that the wiring is not accessible if the readeris removed.4.  Ensure that the LED is always visible to the key holder.5.  If the reader is installed externally, the terminals on the rear of the reader must besealed with a silicone compound to prevent corrosion.Low Profile ReadersThis reader comes in two parts, the reader itself (A) with 4 terminals and the backplate (B). Thebackplate has a rubber spacer at the rear.Mounting the Reader1.  The cable from the controller should be routed through the hole in the backplate. Leaveenough cable exposed to allow easy wiring of the reader (at least 1 inch).Note: There is limited room between the reader and backplate. You should ensure there isa void large enough behind the backplate to accommodate the any excess on thesuppression cable.2.  Mount the backplate to a flat surface using the No.6 screws provided - or a somethingsuitable for the material to which the reader is being mounted. The two holes are 60mmapart. Use the top (round) hole first, and the lower (oval) hole to ensure the reader isstraight.3.  Ensure that the reader cable is not connected to the controller. Wire the reader to the cableas described later in this data sheet and in the door controller Installation Manual4.  Push the reader, with the green LED to the top, onto the backplate, the fixing tabs on eachside should snap into place.5.  Place label on front of reader.
PAC Readers Low Profile, Vandal Resistant and Panel Mount 15729 Ver 1.5DRAFT D© 2003 Blick USA, Inc Page 3Removing the ReaderThe reader can be removed from the backplate by placing a small flat-bladed screwdriver intothe apertures on each side of the backplate. Take care not to damage the reader or backplate.Vandal Resistant ReadersThis reader should be mounted using the vandal resistant screws provided.NoteA special screwdriver (not supplied) is required to use these screws.Mounting the Reader1.  The cable from the controller should come to the rear of the reader. Leave enough cableexposed to allow easy wiring of the reader (at least 1 inch).Note:  The terminals protrude ¼ in from the rear of the reader. You should ensure there isa void large enough (about 1 ½ in square and ¾ in deep) behind the reader toaccommodate the terminals and excess suppression cable.2.  Ensure that the reader cable is not connected to the door controller. Wire the reader to thecable as described later in this data sheet and in the door controller Installation Manual.3.  Apply a silicone sealant to the terminals to protect against moisture if the reader ismounted outside.4.  Mount the reader to as flat and even a surface as possible. This will reduce the possibilityof it being levered from the wall. Either use the Vandal Resistant screws provided, or othersuitable fixings. The LED should be to the top.
15729 Ver 1.5 DRAFT D PAC Readers Low Profile, Vandal Resistant and Panel MountPage 4 © 2003  Blick USA, IncPanel Mount ReaderThis reader is designed to be mounted in a steel panel (E) such as used in a door-entry system.There are two main units; the main module, a black rectangular unit, connected by a fixedlength of cable to a reading head. The cable between the two parts is fixed, 24in/60mm  longand should not be cut, extended or shortened.Panel ApertureThe reading head is designed to fit a 1.57in/40mm square hole. Holes on the reading head,1.89in/48mm between centres, accept M3 (metric) posts (F). The posts should be at least0.59in/15mm long. The front cover (A) protrudes 0.10in/2.5mm through the hole.Locating the Main ModuleMount the module in a convenient place behind the panel. The holes in each corner will acceptNo. 6 screws. Ensure that the module is close enough to the reader head to allow the panel tobe removed without straining the cable. Wire the reader as seacribed in Section 0. Ensure thereis sufficient space for any excess sppression cable.Mounting the Reading HeadThere are 4 components to the reading head:1.  Remove the protective film from the front lexan window (A). Mount on the studs so that thecentre fits through the aperture, with the shallow slot to the bottom.2.  Remove the backing from the label, and fit to the circuit board (C), the clear hole shouldalign with the green LED.3.  Place the circuit board (C) and label over the studs against the window with the cable facingaway from the aperture.4.  Fit the rear lexan cover (D) and clamp using screws suitable for the studs (G).
PAC Readers Low Profile, Vandal Resistant and Panel Mount 15729 Ver 1.5DRAFT D© 2003 Blick USA, Inc Page 5Reader WiringNotes1.  The wiring and location of readers is described in the documentation supplied with thedoor controller. All the readers described in this datasheet have identical terminals.2.  If connected to a PAC 2100 Series Door Controller, it is strongly recommended that a100mA in-line fuse is installed in line with the reader supply.Connecting the Suppression CableOne end of the 6-conductor suppression cable is connected to the reader and the other isconnected to the cable connected to the reader channel on the controller.  The suppressioncable comes with four spade crimps at one end for easy connection to the terminals on thereader. Crimp wire joints are provided for connection to the reader cable from the controller.The following table details suppression cable connections to both the reader and to the readercable from the controller.NoteCare must be taken if a different colour convention for the controller reader cable is usedthan that given in the table.Suppression Cable Controller Reader CableColour Reader Colour PAC 2100SeriesPAC 2200SeriesPAC 202Black -V Black GND GND 0VGreen SIG White SIG SIG1/SIG2 SIGA/SIGBBlue -V Blue DR1 DC/DR1 DCBrown -V Yellow DR2 RTE/DR2 RTEWhite VCA Brown LED LED LEDRed +V Red +18V +18V +VThe following diagram is how we recommend that the cable is wired.
15729 Ver 1.5 DRAFT D PAC Readers Low Profile, Vandal Resistant and Panel MountPage 6 © 2003  Blick USA, IncMOV - Lock SuppressionA Metal-Oxide-varistor (MOV) is provided with each reader. This device prevents back EMF('spikes') being returned from the electric lock to the controller. This can cause severe damageover a period of time, and erratic operation of the system if not controlled.A BThe MOV (A) should be installed across the power terminals of the lock (B). It can be fittedacross the relay contacts on the door controller, but this will be less effective.SpecificationOperating Temperature: -40°C to +50°CCurrent: 100mA (maximum)Supply Voltage: 18V dcCable Type: 4 or 6-conductor, stranded, unshieldedCable Gauge and Distances:Cable Type PAC 2100 Series PAC 2200 Series PAC 20224AWG/0.22mm² 7/0.2 750ft/250m 750ft/250m 230ft/70m *20AWG/0.5mm² 16/0.2 1500ft/500m 1500ft/500m18AWG/1.0mm², 32/0.2 3000ft/1000m 3000ft/1000m* These figures are for readers powered from the controller. The cable distances can beincreased to 1650ft/500m by locally powering the readers.Mean Time Between Failures: >100,000 hoursRFID DevicesAs similar RFID technology is now widely used in a number of other industries, for exampleautomotive immobilisers, it is possible that interaction between your access control credentialand other devices may cause one or the other to function incorrectly. Should you suspect thatyou have experienced such a problem the solution is to separate your access control credentialfrom other RFID devices.FCCThis device complies with part 15 of the FCC rules. Operation is subject to the following twoconditions (1) this device may not cause harmful interference, and (2) this device must acceptany interference received, including interference that may cause undesired operation.Low Profile FCC ID HM3D8201Vandal Resistant FCC ID OQL-P-VNPanel Mount FCC ID OQL-P-PNLChanges or modifications not expressly approved by the party responsible for compliance couldvoid the user's authority to operate the equipment.